Figure 4.1 Schematic of Virginia Tech Calibration Chamber and Accessory Components

Similar documents
L21S/SR/ST Glass Level Gauges

GREIG FILTERS, INC. OPERATION MANUAL

User's Manual. MixRite TF 10. Edition 05.08

Installation/Care/Use Manual Soft Sides Fountains with FLEXI-GUARD

Halsey Taylor Owners Manual

DEVELOPMENT OF A ROBUST PUSH-IN PRESSUREMETER

tel: fax: web:

Fisher and Whisper Disk Diffusers

Halsey Taylor Owners Manual

Inserta Products, Inc.

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

SEADUCER BOATS GAS SPORT HYDRO

Replacing the Reverse Osmosis ( RO ) Membranes

ModelsEZU-15 & EZU-15-R. BISHAMON INDUSTRIES CORPORATION 5651 East Francis Street Ontario, California 91761, USA (909) (800)

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

Installing a Christie One Mount/Christie One Mount Plus

CentriFlow Meter Integrated Air Entrainment System

NCDOT S EXPERIENCE USING HYDRAULIC SETTLEMENT GAUGES. David L. Teague,P.E. NCDOT GEOTECHNICAL ENGINEERING UNIT

Instruction Manual Updated 5/26/2009 Ver. 2.0

tubepress press procedure

Durham Geo-Slope Indicator S-510 Triaxial Cell

Latvin Luxury Shower Panel. Telephone Product Specification. ~ Minimum Working Pressure 1.0 bar ~ Maximum Working Pressure 3.

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

Pressure reduction controller (PN 16, 25, 40)

Site Furnishings 2018 PRODUCT SHEET

Halsey Taylor Owners Manual

Florida Method of Test for MEASUREMENT OF WATER PERMEABILITY OF COMPACTED ASPHALT PAVING MIXTURES

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Continental Industries TRANSITION FITTINGS or FAX Visit

UltRo Dual Flow Reverse Osmosis Water System

DICTATOR "DIREKT" Gate Closer

Constitution Instructions

Agpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE

Ecoflex pre-insulated pipe energy efficiency made easy

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

General Information. Installation Instructions. CP1000 & FCP1000 Folding Markers. Used with: CP1000 FCP1000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Tex-416-A, Air Content of Freshly-Mixed Concrete by the Pressure Method

FITTINGS THREAD LUBRICANTS. Fittings 20,000 PSI

Assembly-, installation- and maintenance instruction manual for bladder accumulators IBV / EBV , top reparable

Water Safety Shut-off Valve HON 790

SCF Enviro-Friendly. Back-up Ring. Endcap. #7141 (for both) O-Ring. Back-up ring and O-ring fit onto end cap.

Pressure Sensing Valve - Model 4023

WARNING: READ THE GENERAL INFORMATION MANUAL INCLUDED FOR OPERATING AND SAFETY PRECAUTIONS AND OTHER IMPORTANT INFORMATION.

Filtered compressed air, lubricated or non-lubricated. Maximum torque on each jaw on opening at 87 psi 3.1 in-lbf 10.6 in-lbf 20.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

VSR modulating valves with membrane actuator

TECHNICAL MANUAL 4'' END PORT PRESSURE VESSEL. Lenntech. Tel Fax.

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Pressure Reducing Valve DMV 755

PARTS - FORWARD. Kayaking + Fishing Parts & Accessories Hook HATCH SEAL "TRIM-LOC" (TOP MOLDED) 5 REQ

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

Flow control valves Series RFU - RFO 2/

Wide opening parallel grippers Series CGLN

IMPORTANT PLEASE READ BEFORE COMMENCING INSTALLATION

OHD L-44 METHOD OF TEST FOR MEASUREMENT OF WATER PERMEABILITY OF COMPACTED PAVING MIXTURES

OPERATING INSTRUCTIONS

NHR Powder Feed Hopper

SOLUTION ASTM F1960. Sioux Chief Tubing. Mr. PEX Tubing. Sioux Chief PowerPEX. Wolverine Brass WOLV-XPEX. Milwaukee Expansion Tools

W A S T E W A T E R T R E A T M E N T S Y S T E M S

OFI Testing Equipment - Aging Cell Instructions Page 1 of 4. Instructions OFITE AGING CELLS

-FRU FREEZE RESISTANT WATER VALVE COOLERS SYSTEM

TEST SPECIFICATION NYT-909-C

Model 7989T Steel Pipe Squeezer Sch. 40 & Sch. 80. Operations Manual

HERZ-Motorised flow controler

Instrumentation & Data Acquisition Systems

Product Catalogue. February We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

Standard Test Procedures Manual

WELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD

Pressure Limiting Valve SPVF Operating Instructions

Universal Anchoring Adapter For Mercedes

ACCESSORIES CATALOGUE. Guarany offers a complete line of accessories to optimize many spraying applications, assuring the best cost-benefit.

Superiorities of MTB Breakers

! CAUTION! ! WARNING! General Information

DICTATOR "DIREKT" Gate Closer

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

Float Equipment TYPE 925/926

Product Catalogue. July We mean progress. PEX plumbing Fire safety Hydronic piping Radiant heating and cooling Pre-insulated piping

Unit 1, Fullerton Road Rotherham S60 1DJ. Tele: Fax:

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

Manual Actuated Boiler Blowdown Valves

ECS Protector Nitrogen Generator PGEN-30 (PGEN-30E)

Bermad Model:

DVS Technical - Codes and Bulletins. Table of Contents

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

- Written price quotations are valid for 30 days from the date of the quote unless otherwise noted.

Wave Cyber (Shanghai) Co., Ltd. 8 Side Port Membrane Housing User s Guide

Instruction Manual. Pipe Friction Training Panel

INSTALLATION INSTRUCTIONS FOR GRT75-PF-RFS PET FOUNTAIN

Product Range. Product Range

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Transcription:

Figure 4.1 Schematic of Virginia Tech Calibration Chamber and Accessory Components 128

Chamber Shell Sample Base Plate 29 mm Bolt Holes Chamber Base Plate a) Chamber Shell Unattached from Bottom Plate - Side view of Chamber Sample Base Plate Guide Posts Steel Rings Actuators b) Firestone Airstroke Actuators - Side View Figure 4.2 Components of Calibration Chamber - Chamber Shell and Air Stroke Actuators 129

a) Sample Forming Jacket Outside Chamber - Side View Fastening Rod Hinge System b) Sample Forming Jacket Outside Chamber - Side View Figure 4.3 Components of Calibration Chamber - Sample Forming Jacket 130

HDPE Liner Water Ports Steel Collar a) Liner and Collar in Chamber - Aerial View O-Ring Groove Cone Insertion Portholes Top Plate Sand Sample HDPE Liner Forming Jacket Chamber Wall b) Top Lid Placed on Pluviated Sample - Side View Figure 4.4 Components of Calibration Chamber - Sample Membrane and Top Lid 131

Figure 4.5 Mechanism Used to Seal Sample 132

John A. Bonita Chapter 4: Virginia Tech Calibration Chamber and Pluviation System Top Plate Top Lid Calibration Chamber HDPE Liner a) Application of Top Lid onto Chamber Shell Wall - Side View Trolley System Vibrator Load Frame Cone Penetrometer Calibration Chamber b) Push System Used in Penetration Testing - Side View Figure 4.6 Components of Calibration Chamber - Top Lid and Push System 133

John A. Bonita Chapter 4: Virginia Tech Calibration Chamber and Pluviation System Sample Forming Jacket Copper Riser Pipe Water Inlet Point (Elbow Fitting) Sample Base Plate HDPE Flexible Tubing a) HDPE and Copper Riser Pipe - Side View Underside of Sample Bottom Plate Air Actuator Copper Tubing b) Copper Tubing on Underside of Base Plate - Side View Figure 4.7 Components of Calibration Chamber - Saturation System 134

John A. Bonita Chapter 4: Virginia Tech Calibration Chamber and Pluviation System Bottom Plate Copper Tubing T- Fitting Guide Post a) View of T- fittings in Saturation System on Underside of Bottom Sample Plate - Bottom View Threaded Elbow Air Actuators b) View of Elbow Fittings in Saturation System on Underside of Bottom Sample Plate - Bottom View Figure 4.8 Components of Calibration Chamber - Saturation System Tubing and Fittings 135

John A. Bonita Chapter 4: Virginia Tech Calibration Chamber and Pluviation System Air Pressure In Backpressure Regulator Manometer Pressure Application Vessel To Sample Figure 4.9 Components of Calibration Chamber - Back Pressure Application System 136

Figure 4.10 Schematic of Air Pluviation System 137

Diffuser Sieves HDPE Liner a) Raising and Lowering Sieves Prior to Pluviation Disgruntled Graduate Student Perforated Plate b) Preparing Perforated Plate Prior to Placing Sand in Bin Figure 4.11 Components of Pluviation System - Preparation of Equipment 138

a) Sand Placement in Storage Bin b) Pluviation of Sand into Calibration Chamber Figure 4.12 Components of Pluviation System - Formation of Sand Sample 139

a) Inside of Storage Bin After Pluviation - Plan View b) Leveling of Sand After Pluviation - Plan View Figure 4.13 Components of Pluviation System - Leveling of Sample 140

Hydraulic Press Rotary Turbine Vibrator Dynamic Load Cells Chamber Lid Cone Penetrometer Figure 4.14 Penetration of Cone Penetrometer into Soil Sample 141