Industrial Compressed Air. Ultrasonic Leak Detection Survey Guide

Similar documents
Best Practices for Ultrasonic Compressed Air Leak Detection

Copyright 2007 by SDT International n.v. s.a. First edition, English version. All rights reserved. Reproduction in any form of all or part of this

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

AIR SAVING PRODUCTS ADDING VALUE AIR-SAVER LOCATOR LOCATOR-EV

AIR-SAVER G1 AIR-SAVER G2 LOCATOR LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

The American Society for Nondestructive Testing

MODEL 9061 ULTRASONIC LEAK DETECTOR INSTALLATION & MAINTENANCE

AIR-SAVER G1 AIR-SAVER G2 LOCATOR-EV COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS AIR SAVING PRODUCTS

Operating Instructions for

DESIGN DATA. Dry 105a. September 5, 2008

Type 3 - PSA Nitrogen Generation System

COMPRESSED AIR DISTRIBUTION SYSTEMS

ASK THE EXPERTS: The Characteristics and Applications of the Ultrasonic Sensor (Part 1 Compressors)

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

Fundamentals of Compressed Air Systems. Pre-Workshop Assignment

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. than the water inlet pressure to the concentrate

User Manual for the Mars Calibration Bench

Gas Measurement Fundamentals Certification. Curriculum

TECHNICAL DATA. Dry 132a. October 1, 2008

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

TECHNICAL DATA. Q = C v P S

TECHNICAL BULLETIN DESIGNING A FUNCTIONAL COMPRESSED AIR SYSTEM

CLASS DH - PNEUMATIC TESTING - GREATER THAN 1 BAR (15 PSIG)

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Type 1 - Nitrogen Generation System. Designed for: Dry or Pre-Action Fire Protection Systems (FPS) with a total capacity up to 750 gallons

CORROSION AT THE AIR-WATER INTERFACE REMOVE THE GAS

Hatch cover tightness testing

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

TECHNICAL DATA. Q = C v P S

Potter Nitrogen Generators

DESIGN DATA OBSOLETE. C. Inspections - It is imperative that the system be inspected and tested on a regular basis. See Inspection

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

628 Differential Pressure Decay Leak Tester

OPERATION MANUAL NTF-15

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

Pressure on Demand. Air Pressure Amplifiers

OPERATION MANUAL NTF-60 Plus

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

HS Bubbler Technology. HyQuest Solutions New Zealand User Group August 2017

TECHNICAL DATA. Q = C v P S

Pressure Calibrators. Series PC..., PM...

FM Approved - Automatic Water Control Valve as standard deluge valve. No formal approval available for coating. Foam Concentrate

TECHNICAL DATA OBSOLETE

CTRL UL101 MORE THAN JUST A LEAK DETECTOR

RC 195 Receiver-Controller

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

Pixel Thermographics Ltd. Compressed Air Leak Detection Survey SAMPLE REPORT. Pixel Thermographics Ltd

/ /

Warning: NEVER ALTER TEST EQUIPMENT

Reliability: Piping Distribution & Storage Matter. Instructor: Kurt Thielemann Principal

Operating Instructions Part No

PRESENTATION OF LEAKSHOOTER LKS1000-V2 01/2017

TECHNICAL DATA. Q = C v P S

NGP-250/500 Nitrogen Generator Quick Start Guide

100C Air Compressor Kit

OPERATING INSTRUCTIONS Pressure Control System PCS-20 through PCS-100

DoctorKnow Application Paper

OPERATING INSTRUCTIONS

Steam System Best Practices 14 Best Practices for Guide Lines for Boiler Plant Log Books

THE NEW SHERLOG RANGE:

HumiSys HF High Flow RH Generator

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Hodge Clemco Ltd. SG-300 Suction Gun. Owner s Manual. Hodge Clemco Ltd

Inert Air (N2) Systems Manual

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

Operating Instructions Part No

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

Water Weir Flow Controller. Introduction. Safety Precautions. Mounting the Hardware

Energy Management solutions for compressed air and industrial gases. vpinstruments.com

Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

ENERGY CONSERVATION IN PNEUMATIC SYSTEMS. Solutions That Save

200 PSI COMPRESSORS - MODEL NUMBERS

IMPORTANT SAFETY INSTRUCTIONS

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

METHOD 21 - DETERMINATION OF VOLATILE ORGANIC COMPOUND LEAKS. 1.2 Scope. This method is applicable for the

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

AUTOMATIC TIRE INFLATOR # MW-60, MW-60-4WAY & MW-64HP

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

PRO-50 Instrument Supply Regulator

OBSOLETE DESIGN DATA. Foam 301a. February 9, 1998

Bermad Pressure Reducing. Model: 42T

Level MEASUREMENT 1/2016

The Ins and Outs of I/P Transducers

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Wet pipe low flow foam/water system

RASP RX3 Feed UnitTM SPONGE-JET USER MANUAL. Sponge-Jet, Inc. (USA) 14 Patterson Lane Newington, NH

Title: Standard Operating Procedure for Dasibi Model 5008 Gas Dilution Calibrator

INTENDED USE TECHNICAL SPECIFICATIONS

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

THE IMPACT ON ENERGY CONSUMPTION CAUSED BY PRESSURE DROP IN A COMPRESSED AIR SYSTEM

MEDICAL EQUIPMENT CATALOG

TECHNICAL DATA. Q = C v P S

Model PSI Compressor with 3-Gallon Air Tank 12VDC

Water Mist Systems Inspection, Testing, and Maintenance of Water Mist Systems

Cygnus Instruments Ltd

INSTRUCTION MANUAL ULTRASONIC TRAP TESTER UTT 100

Transcription:

Industrial Compressed Air Guide

Introduction For many manufacturers compressed air represents the second or third highest utility cost in their facility. Without an effective maintenance program in place leaks can account for as much as 40% of the total air system demand. Proactive and preventative maintenance efforts with a minimal investment can see the leak target reduced from 40% to a more reasonable 5%. Creating an Effective Air Leak Management Program 1. Establish a Strategy At the heart of any sound strategy lies a goal. What are the goals of your air leak management program? Here are some ideas: Maintain a leak rate of 5% Increase the life of your compressors Heighten employee awareness about energy conservation, and compressed air in general Include constant surveillance of the system for integrity and safety issues Educate employees about compressed air best practices Decrease energy waste Write the goals down and publish them in an area where they can receive constant review. Surely during the process of strategy making questions will arise about the state of the current compressed air system. Managing the system is more than just finding leaks; it s about reviewing it in its entirety looking for areas where improvements can be made. The web is full of resources and there are several reputable consultant companies that offer training and consulting services strictly for compressed air systems. 2. Create a Procedure Some procedural elements of a good leak management program to consider are: Safety Publish a safety guidebook for ultrasonic leak detection, leak repairs, and general inspection of the system Frequency - A compressed air maintenance program involves a complete inspection of your airlines 3-4 times per year. Regular inspections will ensure that new leaks are found, and also confirm that tagged leaks from past surveys were repaired. Know the System Familiarize everyone with the supply side, demand side, number of compressors, operating pressures, and any additions that were made to the system since it was installed. Diagrams Obtain drawings of the system from engineering and check to see they are up to date. Use these drawings to map out a route that will be followed each time an inspection is done. Use

copies of the drawings for making annotations during the leak survey. At the end of the day will you remember the positioning of over 100 leak tags? Equipment Decide what accessories will best suite the leak inspections demanded by the system. More about accessories and their specific applications later on in this handbook. Be sure whoever uses the ultrasonic equipment has received proper certification training from a reputable trainer. Find, Tag, and Fix the Leaks Re-Check Be sure to re check the leak area with ultrasonic detector after the leaks are repaired. Remember the person making the repair may not be the same person who tagged the leak. Also, while making the repair it is possible a new leak was created. Document Everything Make sure management knows the great job done to save company money. 3. Choose the Right Equipment Select the airborne ultrasound sensor to best suit the inspection. Different sensors are designed for different types of inspections. The sensors commonly available include: a. Internal sensor b. Flexible sensor c. Extended Distance sensor d. Parabolic sensor All SDT 170 ultrasonic detectors are equipped with an internal airborne sensor for detection of pressure and vacuum leaks. This sensor is ideal for day to day leak detection where the source of the leak is within reach of the inspector. Use in conjunction with the precision indicator kit (shown in Fig 1) to pinpoint the exact source of leakage. Figure 1 - Internal Sensor of SDT 170 Figure 2 - Flexible Sensor - 21" or 36" or custom For inspections in hard to reach areas, choose the Flexible sensor available in 21 and 36 lengths. It can be bent, twisted and shaped to go into any area that is inaccessible by hand.

Overhead piping in ceilings are prone to leakage but normally inaccessible without a ladder or scissor lift. Inspection is now possible with the EDS Extended Distance Sensor. The unique taper-shape funnels medium distance ultrasonic waves (50 100 ) onto the internal sensor of the SDT 170 providing the inspector with extended distance sensing and extreme directionality. Figure 3 - EDS Extended Distance Sensor Select the parabolic sensor if the leaks you are detecting are outside the range of the EDS (Fig 3). The parabolic shape focuses faint ultrasonic waves onto a super sensitive ultrasonic crystal amplifying and thereby extending the detection range by up to 250. The laser sight pinpoints the exact source of the leakage, or use the rifle sight in bright daylight. Figure 4 - Parabolic Sensor with Laser Sight 4. Setting up the SDT 170 Ultrasonic Detector 1. Attach whichever sensor that was chosen for the inspection to sensor input on SDT 170 (Fig 6, #12), attach headphones to audio output (Fig 6, #10) of 170. Always wear the headphones in the plant. You can t find leaks without them, and they help shield your ears from damaging high level of audible noise. 2. Switch SDT 170 equipment on (Fig 6, #6) 3. Ensure that the sensor is correctly connected to SDT 170 by identifying the sensor in the top left corner of LCD screen (Fig 5, Type of Sensor) 4. Ensure battery charge is sufficient to take measurements by viewing icon in top right hand corner of LCD screen (Fig 5, Battery Load Icon) 5. After ensuring all safety procedures for your facility have been followed, proceed to the required inspection method described on next page. Figure 5 - LCD Display

Figure 6 - Functions of the SDT 170 Leaks can occur at a number of points in a compressed air distribution system. Some of these are: 1. Branch line connection 7. Rubber hose 2. Automatic drain trap 8. Quick coupler 3. Desiccant filter 9. Isolating valve 4. Filter/regulator/lubricator assembly 10. Control valve 5. Filter/regulator/coalescent filter assembly 11. Coil hose 6. Regulator 12. Pneumatic cylinders

5. METHOD FOR LEAK TESTING 1. Set sensitivity using the up or down arrows to adjust the 170 to the environment you will be working in. With the amplitude as high as allowable for that environment, scan with an up and down, back and forth motion. Scan the possible leak area for a hissing sound. Listen and watch the signal. If hissing sound is too loud, decrease the sensitivity of the SDT 170 by pressing the down arrow to a comfortable level. 2. If a hissing sound is heard, get closer to the source of the hissing sound. Press the down arrow to decrease amplitude sensitivity as you get closer if hissing sound gets too loud. 3. When you are near the leak, you may attach the localization probe to pinpoint the source of the leak. Scan back and forth, up and down, to confirm. Watch the SDT screen increase or decrease in signal as you scan. Listen to the sound get louder and fainter as you scan. The spot where the sound is loudest is the leak site. 4. Mark the leak source and repair on spot or tag for later repair. 5. Document leak information (location, type of leak, size of leak, inspector, etc...). The following pages show sample charts that can be used to document and estimate leak size. The following chart demonstrates how supply side air is used on the demand side for industry that does not employ a proper compressed air management strategy. Compressed Air Usage in Industrial Plants (International Average) End users or equipment requirements 43% Leakage to atmosphere 34 % Inappropriate uses of compressed air 16 % Purge air for dryers 5 % Failed drain traps 2 % The above data is an average of information accumulated by Plant Support & Evaluations Inc Audit Division Compressed Air Leakage is the largest loss of Compressed Air in any system. www.plantsupport.com

Sample Leak Survey Log Date Department Leak No. Description (Location) Line Pressure Line Size Line Temp. Leak Size or dbµv Leak Type CFM

Legend for Leak Survey Log Date Department Leak No. Description (Location) date the inspection was done area user of compressed air, i.e., Powerhouse, Packaging, etc. tag number general location description, i.e., above Heat Exchanger, B2312 Instrument Air Line, rusty fitting on line east of separator tank Line Pressure Line Size Line Temp. Leak Size Leak Type SCFM operating pressure of the line 1 ft diameter header, ¼ -inch line, etc. Taken from the bare piping surface if no temperature gauge is installed, not the surface of an insulation pinhole, 1/32 inch, or take a decibel reading. pinhole, weld leak, fitting, gasket, etc. reading from the mass flow sensor or calculated using db estimator.

Volume Flow of Free Air Quantifying leak rates (flow of air) by drawing a correlation between the Decibel and SCFM should only be done by a qualified and certified ultrasound inspector. Since many factors affect the decibel level of a leak it is important that the operator understand each factor and consider them strongly before final quantification. The following table indicates measured decibel levels for a compressed air leak at various pressures. The dbµv levels were observed using the internal sensor of an SDT Ultrawave 170MD Ultrasonic Data Collector. As an additional control 10 SDT 170MD instruments were used for the test to ensure repeatability and accuracy of the data. All ultrasonic units were operating at a center frequency of 38.4 khz. The dbµv measurement was registered at the loudest point of the leak. In industrial applications, because orifice shape can vary, the loudest point is not always perpendicular to the orifice. It can also be confirmed that any SDT 170MD with current calibration certificate can validate itself to this chart. Test Orifice Details Leak orifice: 0.0047 x 0.036 Area: 0.00016 inch 2 Distance from Receiver: 15 Notice The values presented in this table are indicative. They are given solely for convenience and should only be used as a guideline. Factors Effecting Results System Pressure Ultrasound Flow Bar PSI dbµv SCFM SCCM l/h 0.35 5 41 0.062 1756 105 0.42 6 43 0.068 1926 116 0.49 7 45 0.073 2067 124 0.63 9 47 0.083 2350 141 1.05 15 48 0.105 2973 178 1.75 25 58 0.140 3964 238 2.8 40 62 0.194 5493 330 3.5 50 64 0.229 6485 389 4.2 60 66 0.264 7476 449 5.6 80 67 0.335 9486 569 6.3 90 69 0.370 10477 629 Leak orifice size, shape, and configuration Turbulence and parasite ultrasound Distance of the ultrasonic sensor from the leak Angular position of the ultrasonic sensor with respect to the direction of the leak jet of air Receiver transducer characteristics, condition, and calibration Temperature and moisture of the air escaping from the leak these factors, and others, can significantly affect the measurements

Table Showing Hole Size, Leakage and Power Loss Hole Diameter Air Leakage at 90 psig Power Required for Compression Actual Size Dimension SCFM kw 1/16 2.11 0.3 1/8 21.18 3.1 1/4 57.2 8.3 3/8 222.48 33 Information from this chart provided by Atlas Copco Compressed Air Manual, 3rd Edition, August 7, 1981 Electrical Cost for an Air Compressor operating for One (1) Year @ $.045 per kwh Horsepower Dollar Cost (USA) 5 $ 1,414.74 10 $ 2,829.48 20 $ 5,575.74 30 $ 8,405.22 60 $ 16,727.22 100 $ 27,961.92 150 $ 41,942.88 300 $ 83,802.54 500 $ 139,643.16 700 $ 195,567.00 1000 $ 279,369.54 Information supplied by Plant Support & Evaluations, Inc Audit Division www.plantsupport.com

Typical Configuration of a Compressed Air System TO PLANT TO PLANT TO PLANT TO PLANT TO PLANT General Compressed Air Piping Diagram