Submersible Pumps Product Overview

Similar documents
50Hz. water solutions. O SerieS DGO DRO

UCA-UVO-UCB. SUBMERSIBLE PUMPS Lifting of polluted water Commercial use 2 pole - 50 Hz OPERATING LIMITS APPLICATIONS CHARACTERISTICS ADVANTAGES

ECONORESS ELECTRONIC EPS & EPT - ENHANCED PRESSURISATION SET INSTALLATION OPERATION & MAINTENANCE DOCUMENTATION

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Submersible Electric Pumps for drainage of clean and slightly dirty water DIWA Series

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

Aquavar SOLO 2 Frequently Asked Questions

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.

Type 4708 Supply Pressure Regulator

BUBBLER CONTROL SYSTEM

Type 4708 Supply Pressure Regulator

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Expert Hydrostatic Level Transmitters

TB 42. Low maintenance effort saves on time and costs. High variability for vehicle types, construction and expan- sion options

Valve Proving System VDK 200 A S02

Technical Data Sheet MF010-O-LC

Valve Proving System VDK 200 A S06*

Crab and Lobster Live Holding System Part II (Water Pumps, Air Pumps and Pipework)

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

BUBBLER CONTROL SYSTEM

Locator Locator-D-Lux Air-Saver G1 Air-Saver G2

Liquid ring vacuum pumps single-stage

Pressure Switches Application Guideline

NAUTILUS Small pump. Powerful performance. Certified according to DIN 14425, submersible pumps for fire departments

Reverse Osmosis System Installation Guide and Operation Manual.

WE SAY: REFILL PLEASE!

Hot Water Stationary Unit

SIHI LPH-X - Liquid Ring Compressors

erc-o 2 -tech Ò innovative gas systems Markwerbener Str Weißenfels Germany

COMPRESSED AIR SAVING PRODUCTS INDEX. Useful information AIR-SAVER G1 AIR-SAVER G2 LOCATOR. Condensate Management Specialist

KSB Delta Compact Type Series Booklet

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

Screw Compressors 11-22kW

C-Flow Coriolis Mass Flow Meters

Hydro Dome GRUNDFOS INSTRUCTIONS

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Tightness controls TC 1 3 and TC 4

Instruction Manual. RF20C (EXmatic 460) Control unit IM 12B06K07-E-E. 1st Edition

COMPACT Booster Sets Data Book 50Hz

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

Automatic Control Unit. Controlmatic E.2. Type Series Booklet

Dosing & Granudos. Controllers. Chemical Storage. Chemical. Dosing &

KSB Delta Compact Type Series Booklet

Technical Information Conducal CLY421

Product Range. High performance and economic high pressure solutions Made in Germany

APPLICATIONS. Pumping of clean, non-muddy liquids in the housing, agricultural and industrial sectors.

swimming pool technology

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Ultrasonic level transmitter and indicator

GENO -Flushing Compressor Product Data Sheet F 02

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Deep Well Submersible Pump Model MSU/MSUS

RMG Meßtechnik GmbH. Publication No E

Liquid ring compressor

Level control technology

CCT-7320/ROC-2313 Reverse Osmosis Controller

TECHNICAL DESCRIPTION

Magnetic Level Gauges

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

1. PARTS INTRODUCTION ELECTRICAL NOTES INSTALLATION 5/6. 5. START UP 6/7. 6. MAINTENANCE 7/8/9. 7. PRESSURE SWITCH ADJUSTMENTS 9/10.

HBLT-A1 LIQUID LEVEL SENSOR

SPECIFICATIONS ATTENTION

KIT. Small Automatic Water Boosters KIT MODELS

This multi-functional device allows the determination of up to six quality parameters with only one measurement:

Automatic Control Unit. Controlmatic E. Type Series Booklet

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

Flamco Airfix D-E. Installation and operating instructions. 1999, Flamco eps

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

COMPRESSOR PACK SUCTION CONTROLLER TYPE: LP41x

JET SWIM ELEGANCE 70 INSTALLATION AND USER GUIDE

Installation, Operation & Maintenance Instructions

Dean Pump Self-Priming Chemical Process Pumps

3-Way Safety Block DSV

High-performance submersible pressure transmitter For level measurement in hazardous areas Model LH-20

Guideline No.M-05(201510) M-05 AIR COMPRESSOR. Issued date: 20 October China Classification Society

Gas density monitor With integrated transmitter Model GDM-100-TI

SF SERIES CNG COMPRESSOR MODEL HF-4MH. 4 Nm3/Hour Displacement OPERATION MANUAL

SCAM T.P.E. WATER TREATMENT SYSTEM SWT- AP AUTOMATIC PURGE

Liquid ring compressors

Vortex flow sensor VA Di Ex-d with integrated, configurable transducer UVA in a flameproof enclosure for applications in explosive atmospheres

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

Liquid ring vacuum pumps in compact design

Flamco Flexcon M-P Pump automat

GA24 Technical Datasheet

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

Description. Chassis. Cabinet. Long chassis - Type: Dimensions (mm): 2700 x 1200 x 1678

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Type 4708 Supply Pressure Regulator

Columbus Instruments

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

High-performance submersible pressure transmitter For level measurement Model LH-20

VERTICAL AIR COMPRESSORS

Electronic Turbine Meter TERZ 94

Transcription:

TM/TMW 32 Duty chart (2 -pole, 50 Hz) H[m] 10 8 6 TM/TMW 32 Submersible Pumps Product Overview Submersible Pumps Basement drainage pump Applications: Pumping clear or slightly soiled water from tanks, shafts or pits. 4 2 0 0 2 4 6 8 10 12 Q[m 3 /h] Submersible Pumps Submersible Pumps Product Overview TS 40, 40-12, 40-16, 50, 65 Duty chart (2-pole, 50 Hz) H[m] 20 16 12 8 4 TS 40 TS 50 TS 65 TS 40 - TS 65 Submersible wastewater pump Applications: Pumping wastewater containing solids with a max. diameter of 10 mm from Building and surface drainage Environmental protection and sewage farm technology Industrial and process engineering 0 0 4 8 12 16 20 24 28 32 36 40 44 48 52 Q[m 3 /h] CP Duty chart (2-pole, 50 Hz) H[m] CP 32-80 22 20 18 16 14 12 10 8 6 4 2 0 0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 Q[m 3 /h] CP 32 CP 80 CP 50 Submersible wastewater pump Applications: Pumping wastewater containing solids with a max. diameter of 10 mm from Excavation ditches, ponds and shafts Flooded basements Use in fountains LP 40 Duty chart (2-pole, 50 Hz) H[m] 10 8 6 4 LP 40 Self-priming wastewater pump Applications: Pumping wastewater from Excavation ditches and ponds Spraying/irrigation of gardens and lawns Mobile drainage 2 0 0 2 4 6 8 10 12 Q[m 3 /h] TMT/TMC Duty chart (2-pole, 50 Hz) H[m] 10 8 6 TMT/TMC Wastewater pumps Applications: Industrial and municipal use, for example for condensate, hot water and aggressive media 4 2 0 0 4 8 12 16 Q[m 3 /h] 12 As of: 06/2004 - Subject to change without prior notice

Submersible Pumps Product Advantages Submersible Pumps TM/TMW 32 Self-cleaning pump shaft Prevents odour build-up from fluids Easy to install High level of operating safety Simple to use Submersible pumps TS 40, 40-12, 40-16, 50, 65 INOX & Composite Detachable power cable Wide range of performance levels Product Advantages CP Long working life High level of operating safety Can be operated in "slurping" mode (simultaneous air and water intake) Suitable for continuous operation Easy to handle LP 40 High level of operating safety Sea water-resistant Easy to handle Simple to use TMT/TMC High resistance to extreme temperatures Suitable even for aggressive media As of: 06/2004 - Subject to change without prior notice 13

Wastewater/Drainage TM/TMW, TS 40-65, TS 40/12, TS 40/16, CP Product Description Design This submersible pump is suitable for stationary, fully automatic operation. A sufficiently long hose is connected to the pump discharge port for mobile use, while a solid pipe is fitted for stationary use. A fault current safety switch (mandatory for outdoor installations) for a breaking current of 30 ma must be fitted by the customer, in accordance with EN 60335-2.41. TM/TMW Basement drainage pump Type key Example: TMW 32/8 HD TM Submersible pump TMW Submersible pump with turbulator 32 Nominal diameter of delivery connection (DN 32) /8 Max. delivery head (m) HD Suitable for handling abrasive pumping media Applications TM 32 Pumping clear or slightly soiled water from tanks, shafts or pits with the pump installed vertically. TMW 32 Submersible pumps that are used in pump sumps and exposed to soapy water from washing machines, washbasins and showers (for example) have a considerably shorter working life. The large amount of suspended matter contained in this water gradually accumulates in the pump shaft over time, leaving a slimy residue in the pump sump and in the pump itself. To prevent this, regular sump cleaning is required, a procedure which is both time-consuming and expensive. Furthermore, the problem of sludge disposal and possible hygiene implications cannot be definitely evaluated at this stage. The TMW 32 Twister provides an ideal solution in this case. In addition, for TMW: The design of the Twister ensures constant circulation in the pump suction area, thus ensuring that the pump sump is kept clean. Due to the constant turbulence and the fact that this eliminates the suspended matter, odours from the materials handled are not allowed to build up. Maintenance intervals are extended. When you deactivate the twister (see the installation and operating manual), the pump curve is increased by 1 m. Motor Forced-flow casing cooled, stainless steel-cased, dry electric motor with integrated thermal motor protection and automatic restart. Cable A 10 m permanently wired power cable is required for outdoor installations in Germany (VDE), but different regulations may apply in other countries. Pump/Motor Seals There is a mechanical seal on the impeller, a shaft seal on the motor and an oil chamber between both seals. Scope of delivery A fully assembled pump with cable, plug and fitted float switch is provided, together with installation and operating manual. Wastewater/Drainage TM/TMW, TS 40-65, TS 40/12, TS 40/16, CP Product Description 18 As of: 06/2004 - Subject to change without prior notice

Wastewater/Drainage TM/TMW, TS 40-65, TS 40/12, TS 40/16, CP Pump Equipment/Function Pump Equipment/Function TM/TMW 32 TS 40 TS 50 TS 65 TS 40/12/16 CP 32/50/80 Operating mode S3 (intermittent service) Frequency switching/h [%] 25 25 25 25 25 Max. frequency switching/h 60 70 50 40 50 Recommended frequency switching/h 20 20 20 20 20 Operating mode S1 (continuous service) Motor below water Motor above water Pump/motor seals In pumping medium area: Mechanical seal On the motor compartment side: Mechanical seal Shaft seal Oil seal chamber Design Wet sump installation Stationary Portable Submersible Open multi-vane impeller Closed multi-vane impeller Free-flow impeller Turbulator Materials (TMW only) (CP 32/23 and CP 80 only) Motor Cast aluminium Stainless steel Pump Plastic Equipment Motor monitor (temperature) Cast iron (3~400 V model only) Explosion protection (3~400 V model only) (3~400 V model only) Forced-flow casing cooling Pre-assembled (CP 80 only) Power cable [m] 3 10 for: TM 32/8 and TMW 32/11HD 10 10 10 5 10 Detachable power cable Attached float switch / optional optional Built-in check valve body Capacitor box for 1~230 V (CP 32/17only) Hose connection Submersible pumps = available, = not available As of: 06/2004 - Subject to change without prior notice 21

Wastewater/Drainage TM/TMW, TS 40-65, TS 40/12, TS 40/16, CP Technical Data TM/TMW TS Technical Data Approved fluids Washing machine soap and water mixture (without long-fibre particles) TM 32/8 TMW 32/8 TMW 32/11 TMW 32/11 HD TS 40... H 90/5.5 TS 40... H 100/7.5 TS 50... H 111/11 Water from car wash facilities Non-chlorinated pool water Water from firefighting systems Heating water (T max = 35 C) Boiler feed water Condensate Cooling (condenser) water Clean water Untreated wastewater Drainage water Partially desalinated water Rainwater Swimming pool water Sea water Wastewater Aggressive media Performance Power consumption P 1 1~230 V [kw] 0.5 0.45 0.75 0.75 1.0 1.3 1.5 Power consumption P 1 3~400 V [kw] 1.0 1.1 1.5 2.0 2.9 2.9 Rated motor power P 2 [kw] 0.37 0.37 0.55 0.55 0.55 0.75 1.1 1.5 2.2 2.2 Rated current for 1~230 V [A] 2.2 2.1 3.6 3.6 4.0 5.5 7.7 Rated current for 3~400 V [A] 2.0 2.0 3.2 3.6 5.1 5.1 Speed [rpm] 2,900 2,900 Motor Protection class for max. submersion depth IP 68 IP 68 Insulation class F F Frequency switching [per hour] 60 70 50 40 Pump Max. noise level at min. level [dba] 52 55 54 54 Submersion depth, max. [m] 3 10 Fluid temperature [ C] 3 35 3-35 Fluid temperature, short periods up to 3 min [ C] 90 Cable type H07 RN-F H05 RN-F H07 RN-F TS 50... H 122/15 TS 50... H 133/22 OZOFLEX (PLUS) H07 RN-F - Oil-resistant Cable length [m] 10 3 3 10 10 10 10 10 10 10 Cable cross-section 1~230 V [mm 2 ] 1 1 1 1 1 1 1 Cable cross-section 3~400 V [mm 2 ] 1 1 1 1.5 1.5 1.5 Plug Schuko Schuko/CE Type of power cable Fixed Plug (detachable) Activation type direct direct Explosion protection (EEx d II B T4) Threephase current only TS 65... H 117/22 Free ball passage [mm] 10 10 10 10 10 10 10 10 10 10 22 As of: 06/2004 - Subject to change without prior notice

Wastewater/Drainage TM/TMW, TS 40-65, TS 40/12, TS 40/16, CP Technical Data TM/TMW TS Technical Data Dimensions Discharge port [DN/Rp] 1 1 / 4 1 1 / 4 1 1 / 4 1 1 / 4 1 1 / 2 1 1 / 2 2 2 2 2 1 / 2 Hose connection [mm] 35 Weight [kg] 5.2 4.7 6.2 6.2 13.5 14.5 21 22 23 24 Materials TM 32/8 Pump housing PP-GF30 Polypropylene Polyurethane Impeller PP-GF30 Polypropylene Shaft 1.4021 C10/1.4404 Shaft seal on motor side NBR NBR Motor housing 1.4301 1.4404 1.4301 TMW 32/8 TMW 32/11 TMW 32/11 HD TS 40... H 90/5.5 TS 40... H 100/7.5 TS 50... H 111/11 TS 50... H 122/15 TS 50... H 133/22 TS 65... H 117/22 Submersible pumps = available or authorised, = not available or not authorised Note on TS: Models TS 40... H 90/5.5 TS 40... H 100/7.5 TS 50... H 111/11 also supplied as A model (without explosion protection, but including float switch and plug 1~230 V). As of: 06/2004 - Subject to change without prior notice 23

Wastewater/Drainage TM/TMW Pump Curves, Dimension Drawings, Dimensions, Weights, Accessories TM/TMW 32 2-pole, 50 Hz [m] 10 8 3 TMW 32 TM/TMW Pump Curves, Dimension Drawings, Dimensions, Weights, Accessories 1 = TMW 32/8 2 = TM 32/8 3 = TMW 32/11 H 6 2 4 1 2 0 0 2 4 6 8 10 12 14 Q [m 3 /h] Dimension drawings Installation schematics for installations with switchgears 1 ~ 230V 50 Hz Hmin Alarm on On Peak load L h1 h adjustable Base load and alarm D Off Off B min 350 x 350 1000 x 500 Dimensions, weights Discharge port Hose connection Height of the connection Pump diameter Shaft dimensions, min. Switch-on level ± 8 mm Switch-off level ± 8 mm Emptying level, min. L D H x B h1 Rp [mm] [kg] TM 32/8 35 294 165 14 5.2 TMW 32/8 1 1 / 4 293 165 280x350 250 102 30 4.7 TMW 32/11 1 1 / 4 323 165 330x350 280 102 30 6.2 TMW 32/11 HD 1 1 / 4 323 165 330x350 280 102 30 6.2 Weight Accessories Check valve body Rp 1 1 / 4 with drain plug, plastic, nominal pressure PN 4 bar 26 As of: 06/2004 - Subject to change without prior notice

Sewage/Faeces Electrical Accessories Pump Equipment/Function Electrical Accessories ER1-A SK 530 Drain Pump Equipment/Function Control PL1 Applications Drain Control PL2 Drain Control 1 Drain Control 2 Switchgear for controlling pumps Alarm switchgear Number of pumps to be controlled 1 2 1 2 1 2 Electrical connection Direct activation [A] max.10 1) max. 2x8 Max.12 max. 2x12 Max.10 max. 2x10 Star/delta connection optional 1) > 10 A > 10 A Design Microprocessor-controlled Electronic Housing material Plastic Metal optional Equipment Test run Pump start counter/impulse counter LCD display LED/indicator lamp Main switch optional optional Ampere meter Volt meter optional upon requ. optional upon requ. 2) 2) Adjustable delay time Operating hours counter optional upon requ. Level detection Float switch 3) 3) 3) 3) 3) 3) Pneumatic pressure sensor Level sensor (4-20 ma) 4) 4) 4) 4) Electrodes Alarm Mains-operated Built-in (buzzer) Pump Duty Cycling Message/display function Collective run signal Collective fault signal Individual run signal optional Individual fault signal optional Control functions (motor monitor) Thermal winding contacts (WSK) PTC Leakage (DI) Electronic Protective motor switch optional optional Scope of delivery (up to 10 A) (>10 A) (up to 10 A) (>10 A) Float switch Signal horn KAS Submersible pumps = available, = not available 1) For other motor power ratings upon request 2) For direct activation units only (up to 4 kw) 3) In potentially explosive areas only with Ex isolating relay 4) In potentially explosive areas only with Zener barrier As of: 06/2004 - Subject to change without prior notice 95

Applications = available, = not available Drain- Alarm2 Motor protection plug CEE Isolation relay for explosion protection Sewage/Faeces Electrical Accessories Zener barrier Pump Equipment/Function Flashing light Signal horn SK 545 Switchgear for controlling pumps Alarm switchgear Number of pumps to be controlled 1 2 Electrical connection Direct activation Star/delta connection Design Electronic External power pack External power pack Electromechanical Housing material Plastic Equipment LED/indicator lamp Level detection Float switch Level sensor (4-20 ma) Alarm Battery-operated Mains-operated Built-in (buzzer) Message/display function Individual fault signal Control functions (motor monitor) Thermal winding contacts (WSK) Leakage (DI) Protective motor switch 96 As of: 06/2004 - Subject to change without prior notice

Sewage/Faeces Electrical Accessories Description of Accessories Description of Accessories Wilo ER 1-A and Wilo SK 530 switchgears For automatic transmitter control of 1 or 2 series submersible wastewater/sewage pumps. W=228 mm, H=265 mm, D=74 mm Protection class IP 42 Switchover from pump 1 pump 2 (SK 530) Motor protection by WSK or electronic motor switch Transmitter connection for float switch, Type WA 95 Automatic pump duty cycling (SK 530) Selector switches: "Hand-2-Hand-1-0-Automatic" system (SK 530) "Hand-0-Automatic" system (ER 1-A) Connection for high water alarm Volt-free fault signal (changeover contact) and volt-free run signal (changeover contact), Phase failure monitor (can be switched off) Includes float switch WA 65, cable length 5 m (2x for ER 1-A, 3x for SK 530) and 230 V signal horn (requires external power supply), included separately in delivery For control of pumps in potentially explosive areas, Ex isolating relays must be used. Switchgears are not explosion-protected and may be used outside of potentially explosive areas only. Submersible pumps P 1 P 2 OK. Drain. Control Control Microprocessor-controlled switch unit for the fully automatic control of 1 or 2 submersible wastewater/sewage pumps. Hand-0-Automatic switch above membrane keyboard Two-line LCD display with 2 x 16 characters, multi-lingual, menu-controlled operation possible using membrane keyboard Input terminals for connecting a level probe Automatic phase failure and phase sequence control Operating hours counter Automatic pump duty cycling (Control 2) after each operation sequence Volt-free contacts for: Collective fault signal Signal horn (make contact) Pump 1 operation (make contact) Pump 2 operation (make contact) Control 2 only Main switch Built-in electronic motor current monitoring max. ambient temperature 40 C Housing: Plastic for wall installation Type of start-up: Direct or star-delta For control of pumps in potentially explosive areas, a level probe (with Zener barrier!) or float switch in conjunction with Ex isolating relays must be used. Switchgears are not explosion-protected and may be used outside of potentially explosive areas only. Niveau Control PS1-LCD Control PL 1 Switchgear for level control of 1 submersible pump using the bubbling-through or dynamic pressure method. LCD display LEDs for alarm, operation/delay time, manual/automatic operation Volt-free contacts for collective fault signal and high water alarm Forced switch-on of the pump Time-delayed pump stop Built-in buzzer Operating hours counter Switchgears are not explosion-protected and may be used outside of potentially explosive areas only. As of: 06/2004 - Subject to change without prior notice 97

Sewage/Faeces Electrical Accessories Description of Accessories Wilo. Drain. Control 1 2 Control PL 2 Switchgear for level control of 2 submersible pumps. The level can be detected using the bubblingthrough or dynamic pressure method or using an electronic level sensor (4-20 ma) or float switch. LCD display, multi-lingual, adjustable LEDs for alarm, operation/delay time, manual/automatic operation Volt-free contacts for collective fault signal and high water alarm, pump 1 fault, pump 2 fault Forced switch-on of the pump Time-delayed pump stop Automatic pump duty cycling after each operation sequence Automatic fault switchover Built-in buzzer Operating hours, pump start counters For control of pumps in potentially explosive areas, a level probe with Zener barrier or float switch in conjunction with Ex isolating relays must be used. Switchgears are not explosion-protected and may be used outside of potentially explosive areas only. Wilo KAS Mini alarm switchgear with 70 dba signal bell, signal transmitter (electrode) with 3 m cable, selfrecharging power supply pack (power reserve approx. 5 hrs.) in ISO plug housing (Schuko), protection class IP 30, 230 V~ / 9V=; 1.5 VA. Wilo Drain-Alarm 2 Alarm switchgear for wall installation with visual and acoustic alarm signal (85 dba buzzer, self-recharging power supply pack, volt-free contact, ISO housing, protective class IP 54, 1~230 V. As the transmitter, a WA type float switch is required. DrainAlarm 2 Protective motor switch CEE (Up to rated motor power P2 < 4 kw) with phase inverter and rotation direction indicator, thermal motor protection of the motor. Current ranges: 2.6 3.7 A 3.7 5.5 A 5.5 8 A 8 11.5 A For TP 80/TP 100, evaluation of the thermal motor protection and leak monitoring. Level probe For level detection. Protection class IP 68 Measurement range 0-1 m WS; 0-2.5 m WS Cable lengths 10, 30 or 50 m Output signal 4-20 ma 98 As of: 06/2004 - Subject to change without prior notice

Sewage/Faeces Electrical Accessories Description of Accessories Float switch MS1 Cable length 10 m, for sewage containing faeces, for connection to a Control 1 or 2. Type WA Float Switch Cable length 5 m, switch setting: high ON/low OFF WA 65 for media up to 65 C WA 95 for media up to 95 C Submersible pumps 1 2 N L 3 4 5 6 7 8 Ex isolating relay For installation of float switches in potentially explosive areas. Suitable for connection of 3 5 float switches. Built into an ISO housing, protection class IP 54, with transparent cover, for wall mounting (W = 182 mm, H = 180 mm, D = 165 mm). 3-circuit (3 float switches can be connected) 4-circuit (4 float switches can be connected) 5-circuit (5 float switches can be connected) Zener barrier For installation of a level probe in potentially explosive areas. Suitable for connection of a level sensor. Protection class IP40, housing for installation in non-potentially explosive areas (W = 75 mm, H = 150 mm, D = 106 mm). 1 m pre-attached cable. Switch cabinet - outdoor installation of -System Empty cabinet for outdoor installation, with glass fibre-reinforced polyester, with lock, air supply and exhaust. For pedestal mounting. Additional options such as ammeter, volt meter, heating, etc. feasible on request and can, if required and in conjunction with a -Control, be supplied assembled in the switch board (at extra costs). (W = 590 mm, D = 320 mm, H = 875 mm) Flashing light For installation on control cabinet, outdoor installation, 230 VAC As of: 06/2004 - Subject to change without prior notice 99

Sewage/Faeces Electrical Accessories Description of Accessories Signal horn For connecting to a Control, 230 VAC Dynamic pressure system The pressure sensor (bell) senses changes of the fluid level in the shaft. The change of the pressure value in the bell is transmitted to the Control PL via a leak-proof hose, and evaluated by measuring elements in the switch box. Scope of delivery: Submersible bell wit 10 m hose Bubble-through system Dynamic pressure principle with permanent compressed air supply from the mini air compressor. The bell (dynamic pressure system) must be ordered separately. Scope of delivery: Mini air compressor, 3 m hose with T-piece and non-return valve Wilo-SK 545 Trigger device for monitoring of up to 2 Wilo TP 80,100 or 150 submersible pumps For installation into existing switchgear or as a module for conventionally designed switchgears, installation on 35 mm top hat rail Phase sequence monitoring 2-stage leak monitoring Thermal winding monitoring (WSK) Operating voltage 3~400 V max. 6 A fuse protection Volt-free output contacts, max. load 250 V/1 A Dimensions : H = 72mm, W = 100mm, D = 113mm 100 As of: 06/2004 - Subject to change without prior notice

Sewage/Faeces Submersible pumps As of: 06/2004 - Subject to change without prior notice 101