Similar documents
BETTIS J1-RT2 RATE OF DROP LINEBREAK DETECTION SYSTEM. FACTORY SET: psi/min psi P/L

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

ACCUMULATOR OPERATING & MAINTENANCE INSTRUCTIONS

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Gas Hydraulic Valve Operator

64 Series Pressure Reducing Regulators

Type S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

Type ACE97. Introduction. Installation. P.E.D. Categories. Specifications. Overpressure Protection. Installation Guide English May 2002

TECHNICAL DATA. Page 1 of 12

Anderson Greenwood Series 400 Diaphragm Pilot Operated Safety Relief Valves. Installation and Maintenance Instructions for

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

TECHNICAL DATA CAUTION

Powers Controls D Day-Night Thermostats

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Types S100K and S102K Pressure Regulators

Product Manual. Description. Specifications. CVS Type 1301F and CVS Type 1301G Regulator. Introduction

Manual Actuated Boiler Blowdown Valves

MEGR-1627 Instruction Manual

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Float Operated Level Controllers

OPERATION MANUAL NTF-60 Plus

OPERATION MANUAL NTF-15

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

RC 195 Receiver-Controller

Types S108K and S109K Pressure Reducing Regulators with Integral Slam-Shut Device

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

DS05C,D,G Dial Set Pressure Regulating Valves

TECHNICAL DATA. Q = C v P S

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Anderson Greenwood Series 93 Positive Pressure POSRV Installation and Maintenance Instructions

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

OPERATING AND MAINTENANCE MANUAL

The Ins and Outs of I/P Transducers

1305 Series Pressure Reducing Regulators

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

SERIES 500 VARIABLE RANGE PNEUMATIC DIFFERENTIAL PRESSURE TRANSMITTER

Oxygen Usage Best Practice Guide

1805 Series Relief Valves

C645A-E Pressure Switches

Type FL Pressure Reducing Regulators

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

1200B2 Series Service Regulators. Instruction Manual

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Pressure Dump Valve Service Kit for Series 2300 Units

Smooth Vent Valve XVD. Series

WW-730. Pressure Sustaining/Relief Control Valve

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

NGP-250/500 Nitrogen Generator Quick Start Guide

299H Series Pressure Reducing Regulators

CSC-2000 SERIES. Reset Volume Controllers MADE IN U.S.A. DESCRIPTION MODELS SPECIFICATIONS ORDERING

Operation & Maintenance Manual Place this manual with valve or person responsible for maintenance of the valve

V DGX Series. Direct-Operated Regulators Manual D103834X012

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

Smooth Vent Valve. XVD Series

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Installation, Operation, and Maintenance Manual

Operation & Service Manual

Pressure Dump Valve Service Kit for Series 3000 Units

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Operation Manual Piston Sensed Gas Pressure Regulators

2.0 INSTALLATION & SERVICE

Type ACE95jr Tank Blanketing Valve

Pneumatics. ZF Marine Pneumatics

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Pressure on Demand. Air Pressure Amplifiers

TECHNICAL DATA OBSOLETE

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Pressure Sensing Valve - Model 4023

DUAL 444C ONBOARD AIR SYSTEM

Unit 24: Applications of Pneumatics and Hydraulics

SALCO PRODUCTS, INC. PRESSURE RELIEF VALVE STORAGE, INSTALLATION, OPERATING, MAINTENANCE/TESTING, AND INSPECTION INSTRUCTIONS

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

Anti-flood device Model B-1

BCV31 DN40 - Blowdown Control Valve

PRO-50 Instrument Supply Regulator

Type R622 Pressure Reducing Regulator

PVQ 13 A2 R SE 1 S 20 C-11 D

D05 Pressure Regulating Valves

RB Series Regulating System

LRS(H)4 Pressure-Reducing Regulator User Manual

Mooney* FlowMax* Regulator

Hydraulic Piston Accumulators

1800C and 1800C-HC Series Service Regulators

Hi-Force Limited Prospect Way Daventry Northants NN11 8PL United Kingdom Tel: +44(0) : Fax: +44(0) : Website:

MADILL 24.7" 365 TILT SET-UP PROCEDURE WITH REXROTH VALVE ON MACHINE

Adjustable. Unloader Valve. O&M Manual. Part #

Types 749B and R130 Changeover Manifolds

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

DS06D,G Dial Set Pressure Regulating Valve

Type CT88 Backpressure Regulator

RD(H)20/25 Pressure-Reducing Regulator User Manual

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Transcription:

Bettis Canada Ltd. 4112 91A Street Edmonton, Alberta, Canada T6E 5V2 Tel: (403) 450-3600 Fax: (403) 450-1400 SERVICE MANUAL No. I-0043 Edmonton GAS/HYDRAULIC ADDITIONAL COMPONENTS CUSTOMER: P.O.#: W.O.#: TAG: DATE: APPLIES TO OPERATOR MODEL: I-0043--.WPD/1 REV5:APR-11-98

TABLE OF CONTENTS DESCRIPTION DWG.NO PAGE APPLICABL E I GENERAL SERVICE NOTES... 3... Y SP PILOT ASSEMBLY... APB1280... 6... Y / N SP PILOT RANGE TABLE... IB0211... 7... Y / N II TESTING AND CALIBRATION OF SP PILOT... 8... Y / N PRESSUREMATIC ASSEMBLY... APB0570... 9... Y / N III PRESSUREMATIC SET POINT ADJUSTMENT...10... Y / N J-1 DIFFERENTIAL PRESSURE PILOT... A-0316...12... Y / N IV J-1 TEST PROCEDURE...13... Y / N R324 REVERSING RELAY... C-0047...15... Y / N A424-HP 4-WAY RELAY... C-0370...16... Y / N DPS-2F DIFFERENTIAL PRESSURE SELECTOR ASSEMBLY... APB0530-2.. 17... Y / N LPS-1 LOW PRESSURE SELECTOR VALVE ASSEMBLY... APB0527...18... Y / N HPS-2 SHUTTLE VALVE... AP-1393...19... Y / N HPS-1 SELECTOR... APB0537...20... Y / N MUFFLER...21... Y / N C8A CHECK VALVE... AP-1109-10.. 22... Y / N CONANT SIGNAL SELECTOR...23... Y / N DECAL, GAS / HYDRAULIC OPERATION, LP SELECTOR... SP-9245-01.. 24... Y / N MERCER RELIEF...25... Y / N HONEYWELL THREE-WAY SOLENOID VALVE...26... Y / N REXROTH SHUTTLE VALVE...31... Y / N PRESSURE SWITCH (ES)...33... Y / N GGTX-88 FILTER... C-0290...38... Y / N FD-1F V2 FILTER... C-0229...39... Y / N DD-1F DEHYDRATOR... C-0222...40... Y / N SJ31-B JUNCTION BOX... CB0168...41... Y / N V NOTES...42... Y / N (i-0043--.wpd) 2

I GENERAL SERVICE NOTES Refer to applicable SCHEMATIC DRAWING(S). THE ITEMS BELOW WILL HAVE BEEN SUPPLIED IF SPECIFIED. The comments are applicable across the range of makes and models. ITEM COMPONENT 7 SPEED CONTROL VALVE A variable orifice which allows for independent control of opening and/or closing speed. 8 CHECK VALVE Permits flow in one direction only. 13 RELIEF Signal gas overpressure protection. 14 PILOT (HI AND LOW) Optional, if required, to switch signal gas depending on status of sensed pressure. Consult pilot bulletin for service and adjustments. 16 SIGNAL SELECTOR Typically to switch from automatic to manual operation for start-up etc. 19 JUNCTION BOX Provides additional terminals for wiring purposes. 20 SOLENOID VALVE(S) Converts electrical signal (E/P) (I/P) to pneumatic signal. See manufacturer's service bulletin at end of this manual. (i-0043--.wpd) 3

... continued GENERAL SERVICE NOTES 22 VOLUME TANK Power gas storage for failsafe operation. Drain accumulated moisture and contaminants using pipe port provided. 23 RELIEF VALVE Supply gas overpressure protection. 25 REVERSING RELAY Bettis relay model (R324) N.O. relay. When reassembling, be careful to align body parts while bolts are just snug, before tightening completely. 27 PRESSURE SWITCH - static Converts pipeline pressure to an electrical signal to provide a low pressure power gas warning or desired position of the line valve. 29 PRESSURE SWITCH - differential Converts a pressure differential between two selected points to electrical signal. 30 PRESSURE SELECTOR VALVE Allow selection of "HIGH" and "LOW" signals for devices 31 PRESSURE SWITCH - static Monitors signal gas pressure. 32 DIFFERENTIAL PRESSURE PILOT Monitors differential pressure between two selected points; applies or removes a signal to operator control package. 35 SHUTTLE VALVE Common application of shuttle valve is "OR" circuit. Permits flow in one direction only. (i-0043--.wpd) 4

... continued GENERAL SERVICE NOTES 36 LOW PRESSURE SELECTOR Selects the lower of two pressures for input to a device. 39 PRE FILTER Removes contaminants from supply gas. 79 PILOT (HI OR LOW) Monitors pressure at a point; applies or removes a signal to operator control package. 82 4-WAY 2-POSITION SWITCHING RELAY Reverses two signals. 85 MUFFLER Reduces exhaust noise. 94 MOLECULAR SIEVE DEHYDRATOR Removes water from instrument gas. (i-0043--.wpd) 5

II TESTING AND CALIBRATION OF SP PILOT Refer to the typical assembly drawing on page 6. The SP pilot piston and spool must be cycle 20 times in order to seat the o-ring seals, prior to testing and calibration. A. PISTON LEAKAGE TEST 1. Apply 100 psig air to the 1/2 NPT pilot port connection and maintain for 1 minute. 2. Using Snoop, check for leakage at the vent port. No visible leakage is permitted. B. VALVE SPOOL LEAKAGE TEST 1. Apply 100 psig at the 1/4 NPT supply port connection on one end body (1) with the second end body (1) connection plugged, and maintain for 1 minute. 2. Using Snoop, check for leakage at the centre body (2) port, joints between body sections (1,2), and ends of body sections (1). No visible leakage permitted. C. PILOT CALIBRATION 1. Adjust the spring compression according to the calibration table on page 7. Interpolation may be used to estimate spring compression for intermediate set-points. 2. Apply 100 psig supply pressure at the 1/4 NPT supply port connection, stamped "SUP", via a closed isolation valve. 3. Apply required pilot pressure at the 1/2 NPT pilot port, on the adapter, via a pressure regulator and closed isolation valve. 4. Install and adequately rated pressure gauge at the 1/4 NPT signal port, stamped "SIG". 5. Open the supply and pilot isolation valves. a) For signal "ON" with increasing pilot pressure, using the pressure regulator, gradually increase pilot pressure at a rate of 20 psi/minute until signal pressure switches on. Record the actual set-point pressure. b) For signal "ON" with decreasing pressure, using the pressure regulator, gradually decrease pilot pressure at a rate of 20 psi/minute until signal pressure switches on. Record the actual set-point pressure. 6. Adjust the spring compression as required and repeat step 5, until the required set-point is reached. Hand tighten the locknut (8) to maintain set-point. 7. Stamp the nameplate (25) as required and mount on the spring cap (9). The complete designation per AP-1299 must be stamped on the nameplate. (i-0043--.wpd) 8

III PRESSUREMATIC SET POINT ADJUSTMENT; SERIES 2000, 2200, 2400 Refer to drawing APB0570 on page 8. This is done with the assembly complete and supply air on the pilot valve for P-AR and P-MR models. NOTE: In the field this requires a calibration kit able to supply high and low setpoint pressures (eg. nitrogen bottle with block & bleed valve). 1. Cases with low and high set points: THE LOW SET POINT MUST BE ADJUSTED FIRST. IT WILL NOT BE AFFECTED BY THE HIGH SET POINT ADJUSTMENT BUT, THE HIGH SET POINT IS AFFECTED WHEN THE LOW SET POINT IS ADJUSTED. a) Set the high trip bolt fully away from the trip spring. b) Repeatedly adjust the low trip bolt and decrease pressure through the low set point until the low trip occurs consistently at the low set point. Tighten the lock nut and recheck. Check that there is at least 0.02" piston travel from low trip to bottom stop. NOTE: When adjusting the low trip bolt, the upper arm of the trip spring must be pushed down. This unloads the bolt and allows it to be turned by hand. c) Repeatedly adjust the high trip bolt and increase pressure through the high set point until the high trip occurs consistently at the high set point. Tighten the lock nut and recheck. 2. Cases with low set point only: a) Set high trip bolt fully away from the trip spring. b) Adjust the low set point as described in item 1.b) above. c) To disable high trip: Increase pressure until the piston is at the upper stop. Adjust high trip bolt downward until high trip occurs, then retract 1/2 turn. Check that high trip does not occur when the piston travels to the upper stop. This high trip bolt adjustment is to prevent the trip spring from placing unnecessary force on the spool. (i-0043--.wpd) 10

IV J-1 TEST PROCEDURE Following is: High Pressure Test, Leak/Blowby Test, Microvalve Alignment, and Calibration Check for correct port designations... H.. HIGH SIDE, L.. LOW SIDE, as per drawing A. HIGH PRESSURE TEST Without microvalve installed or if it is installed, adjust trigger bolt fully into stem so that over travel damage will not occur to microvalve. Remove spring cover, adjust nut, and range spring. H..port connect a regulated 1500 psi supply, and apply pressure in 100 psi increments checking for leaks at diaphragm, stem seals, and blowby at.. L.. port. Maintain the 1500 psi on H.. port and apply 100 psi supply to microvalve supply port for alignment following. B. ALIGNMENT OF MICROVALVE With supply pressure connected as above; 1. adjust trigger bolt until microvalve is fully triggered, signal is vented, and lock bolt in place with locking nut. 2. check for over travel allowance of microvalve lever should be 0.010" to 0.032" away from trigger bolt. CAUTION: DO NOT FORCE LEVER AWAY FROM BOLT WITH MUCH FORCE. MICROVALVE SHOULD BE ALIGNED FOR PROPER OPERATION 1. reduce H.. port supply to zero. 2. L.. port connect a second regulated supply of 1500 psi and apply in 100 psi increments 1500 psi to L.. port. Checking for leaks at diaphragm and stem seals. 3. Reduce L.. port supply to zero. Disconnect supply so that L.. will be at atmospheric pressure for calibration following. (i-0043--.wpd) 13

... continued J-1 TEST PROCEDURE C. CALIBRATION PROCEDURE From range spring chart select proper range spring, record color code; spring O.D. and length on test check sheet. 1. Install range spring and adjust adjusting nut to hold the spring loosely in place. This can be your ZERO TURN POINT. 2. Apply pressure slowly to H.. port until unit trips. Note pressure on supply gauge, this is the differential pressure across the diaphragm of the J-1. 3. Reduce pressure to zero, adjust range spring preload... increase spring tension for higher differential pressure... decrease spring tension for lower differential pressure D. OPERATIONAL TEST Apply 600 psi then 900 psi to both port H.. and L.. at same time. Block and vent L.. supply slowly while maintaining H.. supply. When J-1 unit triggers note readings of H.. supply gauge and L.. supply gauge. The diff. should be calibrated differential pressure setting. Remove H.. supply, check for blowby by applying 1500 psi to L.. (i-0043--.wpd) 14

V NOTES (i-0043--.wpd/42 orig:db-1992-10-13 rev5:ap/ps-1998-04-11 app dist:(ef)o);(sm)p)