SUPER PRECISION AIR RELAYS

Similar documents
SUPER PRECISION AIR RELAYS

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Series IRV1000/2000/3000

VACUUM REGULATORS CONTENTS

Direct Operated Precision Regulator Modular Style. Standard Specifications

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Electropneumatic Transducer (I/P) Installation, Operation and

Precision Regulator. Series Model Regulating pressure range Port size Page

Precision and Instrument Regulators 1/4" port size

EXH. Specifications. Descriptions. Min. working pressure MPa

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Related Products: Auto Drain Valve. Model/Specifications. Model

Pilot Check Valve: Metal Body Type

High Precision Regulators R210 / R220 / R230 Series

Model 40H Nullmatic Pressure Regulators

High precision pressure regulators G1/4" R210 / R220 / R230 Series

PNEUMATIC PRESSURE CONTROLLERS

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

IR1000-A IR1010-A IR1020-A

RC 195 Receiver-Controller

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Float Operated Level Controllers

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

Operation Manual - PN A MENSOR MODEL 73 SHOP AIR BOOSTER

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Series AMJ. Drain Separator for Vacuum

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Regulator/Modular Style AR1000 to 6000

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

TESCOM 50-4X Series Safety, Installation & Start-Up Procedures

Precision Regulator IR3120

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Precision Pressure Regulators

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

The Ins and Outs of I/P Transducers

INSTALLATION & MAINTENANCE INSTRUCTIONS

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Operation Manual Air Saver Unit ASV5000 Series

VOLUMATIC WATER REGULATOR

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

1200 Series Pressure Regulators

Temperature Controllers

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Masoneilan* 78 Model Air Filter Regulator

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Booster Regulator/Air Tank

WW-730. Pressure Sustaining/Relief Control Valve

Air operated valve. VGA342R Series

WIKA INSTRUMENT CORPORATION

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Installation and User Manual

Model Series 62 Constant Differential Relay

DPC-30 DPC-100. Reference Manual

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

RD(H)20/25 Pressure-Reducing Regulator User Manual

OPERATING AND MAINTENANCE MANUAL

Model 4000 Pressure Controller

Model 130M Pneumatic Controller

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

R84G - Excelon Plus Modular System Pressure regulators

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Leak free Pipe Rupture Valve for Excavators

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

SG3 Series Regulators - Pressure Reducing

Powers Controls RC 195 Multiple Input Receiver- Controller

Model: 720-UL INSTALLATION OPERATION MAINTENANCE. Bermad Pressure Reducing Valve IOM. Model: FP -720-UL Sizes: 2"-12" BERMAD. Application Engineering

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RSV Precision Vacuum Regulator

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Installation, Operation, and Maintenance Manual

product manual HM-4140, HM-4150, HM-4160 HM-4160A HM-4150 Humboldt FlexPanels

256 Pneumatic Pressure Indicator

Powers Controls RC 195 Single Input Receiver-Controller

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

INSTRUCTION MANUAL LOW PRESSURE CALIBRATION PUMP MODEL PGL

B84G - Excelon Plus Modular System General purpose filter/regulator

Smooth Vent Valve. XVD Series

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

WW-720. Pressure Reducing Control Valve

Pressure Regulators. Operating Instructions. Instrumentation

Powers Controls D Day-Night Thermostats

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Air preparation units

VOLUMATIC WATER REGULATOR

Air Operated Hydraulic Pumping Systems to 50,000 psi

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

B74G - EXCELON Modular System General purpose filter/regulator

GS/GSD Series Precision Back Pressure Regulator

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Standard Specifications

Vibration isolation system 1VIS10W. User manual

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

Transcription:

CAT. No. KS-128E SUPER PRECISION AIR REGULATOR rsseries SUPER PRECISION AIR REGULATORS rrseries SUPER PRECISION AIR RELAYS Air Pressure Regulators that attain the ultimate in pressure control.

SUPER PRECISION AIR REGULATORS S/RR SUPER PRECISION AIR RELAYS DESCRIPTION Servo-balanced system comprising Rolling diaphragm and Measuring capsule provides exceptionally precise and stable pressure control with constant bleed feature. Series-RR offers exceptionally precise 1:1 pressure relay control with bias adjustment capability by external pilot operation. RS RR FEATURES Ultra Accurate and Stable Pressure Regulation : Sensitivity 0.1 % F.S. Repeatability 0.1 % F.S. Extremely Excellent Characteristics : in Relief-, Pressure-, and Flow- sensitivities. Particularly, minimum relief pressure as low as 3 10-5 MPa (theoretical Relief sensitivity) finds best applications in Web tension controls and Air balancers, etc. Excellent Start-up Stability : No readjustment of regulated pressure required even after long "down - time". Remote Control of Pressure : (Series-RR ) Advisably used for high precision remote control of pressure. Adaptable Mounting : Mounts at any angle. Bracket, Panel or Pipe mounted. SPECIFICATIONS OP TION 1 2 2 3 4 INTERNAL PILOT EXTERNAL PILOT Working Fluid Clean Compressed Air Set Pressure Range kpa 14 420 14 840 Supply Pressure Range kpa 990 Input Signal Pressure Range kpa 14 840 Relief Function Incorporated Repeatability % F.S. Within 0.1% Pressure Sensitivity % F.S. Within 0.1% Relief Sensitivity kpa 0.03 (Theoretical) Relief Flow Rate /min(normal) 130 260 Air Consumption /min(normal) Within 3.7 Operating Temperature 5 60 Pipe Port Rc RS = 1/8, 1/4, 3/8 ; RR = 1/4, 3/8 Gauge Port Rc 1/4 (Two Ports) Accessory Parts Mounting Bracket (Standard) Weight kg RS = 0.75, RR (std.)=0.72, RR (W.Bias knob)=0.78 ( 1 ) Bias Adjusting Knob BA (Series RR) Turrning of BA knob effects bias pressure within the range of 0.2MPa ( 2 ) Pressure Gauge G : Accuracy 1.5 % F.S. OPT.No. Unit Pressure Range Min.Graduation G025 MPa 0 0.25 0.005 G060 MPa 0 0.6 0.01 G100 MPa 0 1 0.02 Note : 1 Applicable to Series-RR only. 2 F.S. = Full Scale. 3 At Set pressure 0.2MPa 4 Because of air bleed servo control action, a small amount of air escapes normally into atmosphere. MODEL DESIGNATION Example 1

PRECISION AIR REGULATOR TYPICAL CHARACTERISTIC CURVES & ADJUSTMENT Pressure Characteristic Flow Characteristic Relief Characteristic BIAS PRESSURE ADJUSTMENT PROCEDURE (Series-RR) JIS SYMBOL Series-RS (Internal Pilot) First apply pressure to primary port. After that, input signal pressure. The reverse order may cause failure of capsule. Depress fully Bias knob and turn it to engage the slit of Capsule screw. Series-RR (External Pilot) Turn Bias knob clockwise / counter clockwise to increase / decrease bias pressure (up to + 0.2MPa / -- 0.2MPa ). Exceeding these limits may cause failure of Capsule. Adjusted in Zero bias condition when shipment Series-RR does not regulate below 14kPa output pressure,as a minimum output pressure is necessary to provide bleed air to Pilot pressure chamber. 2

OUTSIDE DIMENSIONS RS SERIES EXPL A NATORY CONSTRUC TION AND PRINCIPLE OF OPERATION Series-RS (Internal Pilot) Series-RS and Series-RR have the same construction and perform pressure control with the same operating principle, except that Series-RR can control output pressure with a pilot signal pressure externally applied. Series-RR (External Pilot) PRINCIPLE OF OPERATION Series-RS and -RR utilize a servo balanced system in which Supply -and Relief - valves are operated by a pilot valve. The pilot valve is opened or closed by expansion or contraction of a sensitive Measuring capsule. The regulated pressure is conducted into Control chamber and surrounds Capsule, the "heart" of the regulator. Measuring capsule offers extreme stability of movement under all operating conditions. A small amount of air flows normally through Pilot valve into Pilot pressure chamber and out through Bleed orifice to atmosphere, assuring the stable pilot pressure. A small change in output pressure will cause Capsule to flex slightly and thus move Pilot valve, resulting in a substantial change in the Pilot pressure. In turn, this change upsets the force balance of Diaphragm assembly, which causes an appropriate movement of either Supply or Relief valve, thus correcting (COMMON TO RS AND RR ) any small error in output pressure. Eventually, Capsule and Pilot valve return to their initial equilibrium positions respectively. The primary reason for the ultra high accuracy is the fact that the movement of Pilot valve, required to effect substantial changes in Supply valve position is extremely small. The high gain of this servomechanism permits desired output pressure to be maintained with exceptional accuracy and repeatability. Manual adjustment of Control knob provides sensitive setting of output pressure (Series-RS) or bias pressure (Series-RR). RELAY FUNCTION (FOR SERIES-RR ONLY) A change in Signal pressure to cause similar flexure of Measuring capsule requires an exactly equal change in output pressure to return Capsule and Pilot valve to their equilibrium position. This gives Series-RR its precise 1 : 1 ratio pressure relay control characteristic with bias adjustment capability by external pilot operation. 3

RR SERIES RR SERIES < with Bias Adjustmemt Knob BA > 4

RS RR SERIES APPLICATIONS FUJIKURA S Super Precision Air Regulators and Air Relays (Series-RS and Series-RR) are widely used in precision control applications such as : Web Tension Control : Combined with Double - Action Super Cylinder (Model SCD, Ultimate low friction type) and Electro= Pneumatic Transducer (Series-RT). Printing machine, Paper Processing machine, Plastic Film Processing machine, Textile machine, etc. Push - down Pressure Control : Combined with Double-Action BF Cylinder (Model FCD) and Electro-Pneumatic Transducer (Series-RT), Grinding machine, Abrasion Testing machine, Soil Texture Testing machine, Sheet Cutter, etc. Volume Boosting and Remote Loading : Valve control for instrumented equipment, etc. Different Settings of Secondary Pressure by Remote Control : (1) Web Tension Control (2) Push-down Pressure Control (Grinder) (3) Volume boosting and remote control (4) Remote-controlled setting of Different pressures ( Multiple outputs) < Note> FCD : BF Cylinder (Standard Cylinder. Cat No. KS-570E) SCD : BF Cylinder (Super Cylinder. Cat No. KS-570E) R P : Precision Air Regulator (Cat No. KS-129E) R S : Super Precision Air Regulator (Cat No. KS-128E) R R : Super Precision Air Relay (Cat No. KS-128E) RRHR : Super Precision Air Relay (High Relief type, Cat No. KS-128E) R T : Precision Electro-Pneumatic Transducer (Cat No. KS-130E) 5

CAUTION INSTALLATION AND PRECAUTIONS PRECAUTIONS COMMON TO SERIES-RS AND SERIES-RR Flush out all air lines throughly to remove dirt and scale before installation is made. When plumbing connections, apply seal tape onto male threads starting with 3rd. thread back away from end to avoid possibility of getting the tape or sealant into the regulator and air line. Drain and dirt in supply pressure line will cause malfunction of Regulator. Be sure an Oil-mist separator together with an Air filter (of 5 micron or less) are installed ahead of the regulator in the air line. Locate a Lubricator, if necessary, downstream beyond the regulator. Connect supply air to IN port and output to OUT port as marked on bottom of Body. A slight hissing sound of bleed air is the proof of normal air bleed servo control action. Should bleed air be blocked shut, remove Bleed screw and clean Exhaust vent for proper regulating operation. INSTALLATION ( SERIES-RR ONLY ) A change in signal pressure effects a exactly equal change in output pressure. In the input signal pressure line, use a Pressure regulator with accuracy suitable for particular application. Connect input signal pressure pipe line to either one of two pilot pressure pipe ports on the top of Body. Excessive tightening of Bias adjusting screw may cause failure of Capsule. If you have any question or special application need, FUJIKURA are ready to assist you. Please consult us at the address printed on the back cover. 6

PRECISION AIR REGULATOR Fujikura's Pneumatic Control Products Line Precision Pneumatic Control Products General Guide Cat. No. KS-572E Precision Air Regulators Series RP Cat. No. KS-129E Precision Electro-Pneumatic Transducers Series RT Cat. No. KS-130E Precision Vacuum Pressure Regulators Series RV Cat. No. KS-131E Precision BF Cylinders Series FC Cat. No. KS-570E Please request respective catalog for detailed contents of each product. Note:Specifications subject to change without notice for improvements and modifications. Control Equipment Division : 840, Mihashi 1-chome, Omiya-ku, Saitama-city, SAITAMA PREF. 330-0856, JAPAN Phone: 81-48- 663-1820 Facsimile: 81-48- 663-8630 URL http:// www.fujikurarubber.com/ced/ E-mail cegs@fujikurarubber.com Head Office : 2-11-20 Nishi-gotanda, Shinagawa-ku, TOKYO 141-0031, JAPAN Phone: 81-3- 3490-2111 Facsimile: 81-3- 3490-2170 Printed in Japan