OC Panel High Limit Aquastat Kit, Manual Reset p/n

Similar documents
SPECIFICATIONS ATTENTION

P7911C PressureTrol Controller

Operator: Save these instructions for future use!

Installation Instructions

36H SERIES Combination Gas Valve

36E DSI, HSI & Proven Pilot Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

36E DSI and HSI Two-Stage Combination Gas Valve INSTALLATION INSTRUCTIONS

DANGER WARNING IMPORTANT

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

36E03 and 36E38 DSI and HSI Step Opening Combination Gas Valve INSTALLATION INSTRUCTIONS

VR8205S,T Direct Ignition Combination Gas Controls

Instructions for High Altitude Conversion

ACCESSORY KIT INSTALLATION MANUAL

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

C645A-E Pressure Switches

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

BGA158, BGA171 and BGA110 Series Shutoff Gas Valve

BGA158 Series CE Approved Class A Shutoff Gas Valve

Propane Conversion Kit Instructions

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

A4s Operation Manual

Dual Solenoid Gas Valve Installation

Roller AC Servo System

G92 Series BASOTROL Automatic Pilot Gas Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

BGA158 Series CE Approved Class B Shutoff Gas Valve

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

P7810A-D Pressuretrol Controller

Installation Instructions WARNING: WARNING: WARNING: LP AND HIGH ALTITUDE LP GAS CONVERSION KIT FOR UNITED STATES INSTALLATIONS

Installation Instructions

Operator: Save these instructions for future use!

P7810C PressureTrol Controller

RAM 4021 Operation Manual

GM Series Dual-Block Multi-Function Gas Control Valves

G96 Series BASOTROL Dual Operator Valve

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

A4 Operation Manual. Fig.1-1 Controller Socket Diagram

3 GALLON, OILLESS PANCAKE COMPRESSOR INSTRUCTIONS. Item #31289

AutoChanger Installation & User Guide Issue 2

AE R1 February 2015

36C/36D HSI, DSI Proven Pilot Gas Valves INSTALLATION INSTRUCTIONS

TANK MANAGER FOR TWO TANKS OPERATING MANUAL. 10/31/11 C-More T6C L color touch panel

Installation Instructions For Natural Gas Conversion

Operator: Save these instructions for future use!

RAM 4021-DPX Operation Manual

CCT-7320/ROC-2313 Reverse Osmosis Controller

Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may by reproduced in any form, in an electronic

VR8200A Continuous Pilot Combination Gas Controls

Automatic Valve Proving Control

Conversion instructions from natural gas to propane

BUBBLER CONTROL SYSTEM

Budget Range Operators Handbook

HBLT-A1 LIQUID LEVEL SENSOR

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

V8200A,C,H,M and VR8200A,C,H,M Continuous Pilot Combination Gas Controls

100C Air Compressor Kit

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

Natural Gas to L.P. Gas Conversion Kit

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units Digital Range

Operator: Save these instructions for future use!

FAULT CODE TROUBLESHOOTING INDEX

Operator: Save these instructions for future use!

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

RAM Operation Manual

VR8105, VR8205, and VR8305 Direct Ignition Combination Gas Controls

Operator: Save these instructions for future use!

Smart JVA Module WARNING. For use with AquaLink RS systems with rev R firmware or newer.

NITROGEN INFLATION SYSTEM NG-4, NG-6, NG-12, NG-18

Model PSI Compressor with 3-Gallon Air Tank 12VDC

200 PSI COMPRESSORS - MODEL NUMBERS

444C DUAL PERFORMANCE VALUE PACK

Natural Gas to L.P. Gas Conversion Kit

/2004 US/CA

400C & 450C DUAL PERFORMANCE VALUE PACKS

WARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

Gas Pressure Switch for DMV safety shutoff valves

H15 Series BASO 100% Shutoff, Automatic Pilot Valve

VR8305 Direct Ignition Combination Gas Control

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

IMPORTANT SAFETY INSTRUCTIONS

Gas Pressure Switch for DMV safety shutoff valves

DTG - LCD Digital Temperature Gauge USER MANUAL

Installation Instructions for use by heating contractor

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACV-10 Automatic Control Valve

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

1 STARTUP Overview Buttons Basics of Control Resetting Faults and Alarms OPERATION...

GM-7000 Series CE Approved Gas Control Valve

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

VR46.5V(A)/VR86.5V(A) SERIES

C437D,E,F,G,H,J,K and C637B Gas Pressure Switches

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

200 PSI FAST-FILL AIR SOURCE KIT

! WARNING. Before using this product read and understand instructions.

Transcription:

OC Panel High Limit Aquastat Kit, Manual Reset p/n 233202 Instruction Sheet APPLICATION The OC (Option Control) Panel High Limit Aquastat Kit provides electronic temperature sensing in a UL limit-rated control with a single sensing probe. This Aquastat replaces auxiliary manual-reset high limit Aquastats such as L4006E and L4008E. This product requires the use of one of the following OC (Option Control) Panel Kits: PN 233200 for AWR Gas Hot Water Boilers PN 233201 for FWZ Oil Hot Water Boilers The OC Panel High Limit Aquastat Card may be simply plugged in to the OC Panel and only requires sensor and well installation to become operational. GENERAL This manual reset control requires user intervention to reset a temperature condition after the temperature returns to safe levels. SPECIFICATIONS Listings/Approvals UL353 Limit Controls for both US (UL) and Canada (CUL) Component Recognized UL 1998 Software Safety Standards as a Class 2 device. Add the OC Panel and OC Panel High Limit Manual Reset Aquastat Kit to the temperature control mounted on the boiler from the factory to be fully compliant with CSD-1 requirements for temperature controls in the US and Canada Dimensions: 4.5 in. x 1.5 in. (fits onto OC Panel) Operating temperature: -4 F to 150 F Shipping and Storage: -40 F to 175 F Humidity 0 to 95% R.H. Non-condensing Input ratings: 24 VAC 60 Hz Reset: Manual reset mode Sensor: Dual Sensor, Limit Rated, p/n 350080 (Honeywell p/n 50001464-005) with sensor clip p/n 350077 Well: p/n 35-1005, (Honeywell p/n 123869A), Spud Size:1/2 inch NPT Insertion: 3 inches Insulation: 1-1/2 inches

INSTALLATION When Installing this Product. 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Save instructions for future use. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions.! Caution Electrical Hazard Disconnect power before beginning installation and wiring. Failure to do so may cause electrical shock or equipment damage. Wiring must comply with applicable codes, ordinances and regulations. WARNING! Installation must be performed in accordance with all national and local codes and ordinances. Risk of explosion. Not for use in hazardous locations. Serious injury or death could result. When installations are complete, check for correct operation of ALL limit and operating controls. Use only copper conductors. Wire insulation must be rated at 221º F (105º C) or greater. Use of other wire or insulation types could result in fire causing property damage, serious injury, and death. Hot or pressurized boiler systems can discharge steam and hot water. Cool boiler system to 80º F (27º C) and to 0 psi (0 bar) before servicing. Failure to do so could result in serious burns.! Caution Limit settings are safety parameters and adjusting them incorrectly can have serious consequences.! WARNING Incorrect adjustment can cause equipment damage or serious injury. Adjustment of Limit Settings should be done by trained personnel only.! Important Immersion well must fit sensing element and sensor bulb must rest against bottom of well. Page 2 of 8

INSTALLATION (continued) Sensor clip Sensor clip installed Sensor Installation Diagrams Well and Sensor Installation 1. Turn off all power and drain the boiler. 2. Install sensor with well that was provided with the OC Panel High Limit Aquastat Kit. When using an existing well ensure that the well specifications (Spud Size: 1/2 inch NPT, Insertion depth: 3 inches & Insulation: 1-1/2 inches) match the supplied well and will accommodate the supplied sensor clip. 3. Prepare a properly sized and threaded tapping near the boiler supply water outlet. Choose a location (or existing tappings) that allows the boiler water to circulate freely over the well. 4. Sparingly coat the well threads with pipe dope. 5. Install the well in the boiler tapping and tighten securely. 6. Refill boiler and check for water leakage. 7. Insert the sensor element into the well until it bottoms. See Sensor Installation diagram above for details 8. Insert sensor clip to hold the sensor against the bottom of the well. 9. Route sensor wire and connect to OC Panel High Limit Aquastat Card. 10. Turn power ON. 11. Set High Limit (see User Interface Section of this manual) IMPORTANT Best thermal response is obtained with a well that snugly fits the sensor. Insert the sensor until it rests against the bottom of the well. Use a well of correct length and install sensor clip. If the well is not a snug fit on the sensor, use the heat-conductive compound, (Honeywell p/n 120650) OC Panel High Limit Aquastat Card Installation 1. Turn off power to the boiler before installing the option card 2. Select an unoccupied OC Panel slot and carefully insert pins on the OC Panel header into the connector on the bottom of the option card. NOTE Use caution not to bend the pins. Align all four card guides before gently pushing card into slot. 3. Gently push the option card into the OC Panel option slot until it locks into place. The OC Panel will automatically recognize the card and establish communication. Insert OC Panel High Limit Aquastat Card into selected slot Page 3 of 8

INSTALLATION (continued) Checkout Check to make certain that the OC Panel High Limit Aquastat Card has been installed and adjusted to the proper settings. Put the system into operation and observe the action of the device through several cycles to make certain that it provides proper control of the system as described in the Operations section. Further adjustments can be made to meet more exact comfort requirements. Operation 1. When checking out the system, adjust the control point low enough so the temperature of the controlled medium reaches the high limit setting, the burner shuts off, and the OC Panel High Limit Controller locks out. When the temperature of the controlled medium drops to the high limit setting minus differential, activate the manual reset button (refer to How To Reset The OC Panel High Limit Controller below for reset procedure) and the system should be operative again. 2. Reset control to proper high limit setting. USER INTERFACE OC Panel High Limit Aquastat Card Features LED Flashing Red Green TX Description High Temperature, Lockout and manual reset required or fault indicator Enviracom communication indicator Page 4 of 8

USER INTERFACE (continued) Using OC Panel Display The OC Panel display along with Up, Down, and keys are used to view and adjust OC Panel High Limit Aquastat Card settings. Please note that these keys look similar to the keys on the Boiler Control but are in a different orientation, and they perform different functions. Showing View Mode Options In view mode the user may look at (but not change) status and temperature readings. To view card information: 1. Press and release the button. The following table shows the items that will be displayed in view mode: OC Panel Display Up Key Down Key Key OC Panel User Interface Selecting OC Panel High Limit Aquastat Card To access an Option Card: 1. Press the key. The display will go from to, and (when cards are installed) to provide access to each of the card slots and the card plugged into that slot. 2. Press either the Up or Down keys when the display shows the card number where the OC Panel High Limit Aquastat Card is installed. For example, if the High Limit Card is installed in slot one, press the Up or Down keys when is displayed. View Mode Options High limit setting of Aquastat High limit differential of Aquastat (fixed) Sensor temperature of Aquastat Error (Followed By Error No.) Internal Fault Sensor Failure Lockout, manual reset required (refer to Trouble Shooting Section for more information) Return to OC Panel Card Select Menu Each setting will alternately flash between the relevant display code, its corresponding value and units. For example, when the key is pressed until is displayed, it will then flash a display a number (such as ) and followed by either (or ). This indicates that the sensed temperature is 180 F. Other view mode items display the information in a similar fashion. Unit Display 1 sec 1 sec 1 sec This will switch the display to show the OC Panel Card View Mode. Sample Display OR Please note that in view mode to hold the display on the value the user can press and hold either the Up or Down keys and the value will be continuously shown. This may be helpful in watching a value live. To exit view mode and return to the OC Panel menu: 1. Press the I button to select the " menu item. 2. Press either the Up or Down keys to exit the card menu. OC Panel Option Card Slot Identification Page 5 of 8

USER INTERFACE (continued) Entering Adjustment Mode In Adjustment Mode, the user can adjust the High Limit, change measurement units or reset a high temperature condition. To enter adjustment mode: 1. Press and hold the Up, Down, and keys simultaneously for three (3) seconds while the display is in the Aquastat Card View Mode. While holding the buttons the display will change to an Adjustment mode label signifying to the user that installer mode has been entered. This procedure is intended to discourage unauthorized or accidental changes to parameter settings. 2. After entering Adjustment Mode, Press the key to view the item to be adjusted. 3. Press the Up or Down keys to adjust the displayed setpoint to the desired value. 4. Exit adjustment mode by one of the following means: a. Press the key until option is displayed and press either Up or Down keys b. Press and Hold the Up, Down, and keys until the first item of view mode is shown. c. If no keys are pressed, after five (5) minutes the display will automatically return to the view mode. 5. Once in view mode press the key until option is displayed and press either Up or Down keys to return to the OC Panel Display. How To Reset The Aquastat To Reset the Manual Reset OC Panel High Limit Aquastat Card: 1. Make sure that the temperature has returned to normal. 2. Press key until the Aquastat card slot number is displayed (, or ). 3. Press the Up or Down keys to enter the card's view mode 4. Press and Hold the Up, Down, and keys simultaneously for three (3) seconds, Adjustment Mode items will be shown 5. Press until the Reset ( ) Pushbutton is shown. 6. Press the Up or Down keys to turn Reset on The following table shows adjustable items. Adjustment Mode Options Display Factory Default Range Definition Adjust high limit setting of Aquastat Manual Reset OC Panel High Limit Aquastat Card, fixed High Limit differential Unit Selection ( F or C) Reset from lockout Ready to restore from lockout Not Ready to restore from lockout Return to Option Card View Mode Menu Page 6 of 8

TROUBLSHOOTING OCP High Limit Aquastat Card Error Codes The following errors are reportable via both EnviraCOM and the OC Panel Display. Errors will be displayed in view mode. Display Status Boiler / Control Action(s) Internal Failure Replace Control Sensor Failure Lockout, manual reset required Temperature sensor or interface failure (open or short connection or increased connection resistance, dual sensor mismatch) or control hardware failure When a lockout occurs the boiler will shut down. The boiler will not automatically restart once the temperature has decreased below the High Limit. To Reset the control follow Aquastat Reset pushbutton procedure described on the previous page. Checking Sensor Resistance When checking sensor resistance values it is extremely important to follow the guidelines below or erroneous readings may occur. 1. Use a low volt ohm meter. 2. Check the resistance of the ohm meter leads by connecting them together. Excessive resistance in the test leads will cause inaccurate results. Resistance in test leads should be less than 1 ohm. 3. The sensor should be at a stable temperature for at least 3 minutes before checking the resistance. 4. Assure the water temperature gauge has a reasonable accuracy before depending on it for the reference temperature. 5. Remove the sensor connection at the OC Panel Hi Limit Card and, using the tips of the test leads, check the resistance between pin 1 and pin 2 on the connector. Note that the wire going to pin 2 is marked with a yellow tape band. Using the same procedure check the resistance between pin 2 and pin 3 on the connector. Important: Holding the wires with your hands can cause significant errors. a. The reading between 1 and 2 and the reading between 2 and 3 should be approximately the same. 6. Take the reading as soon as possible as the current flow from the meter through the sensor will cause the sensor to heat and you will get erroneous results. 7. Use the Sensor Resistance Temperature Table on the next page to determine the corresponding temperature. Page 7 of 8

Sensor Resistance Temperature Table Temperature Deg C Temperature Deg F Nominal Resistance, Ohms 0 32 32640 5 41 25390 10 50 19902 15 59 15714 20 68 12493 25 77 10000 30 86 8056 35 95 6530 40 104 5325 45 113 4366 50 122 3600 55 131 2985 60 140 2486 65 149 2082 70 158 1751 75 167 1480 80 176 1256 85 185 1070 90 194 916 95 203 786 100 212 678 105 221 587 110 230 509 115 239 444 120 248 388 125 257 340 130 266 299 Page 8 of 8 Crown Boiler Company Manufacturer of Hydronic Heating Products P.O. Box 14818, 3633 I Street Philadelphia, PA 19134 www.crownboiler.com 980770 8-13