Dean Pump Self-Priming Chemical Process Pumps

Similar documents
DEEP WELL SUBMERSIBLE PUMPS. An ISO 9001 & Company

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

PENBERTHY SERIES LM, ELL, FL, GL, GH, U, L AND 2NC FOR PUMPING GASES

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

Air Operated Hydraulic Pumping Systems to 50,000 psi

TYPE 3710 CARTRIDGE SPLIT SEAL Technical Specification

T Y P E V S A B M S E W A G E P U M P

Model 531A AURORA. 530 Series SINGLE STAGE SUMP PUMPS NSB

PROCESS ROTATING EQUIPMENT (CENTRIFUGAL PUMPS )

pumping gases JET PUMP TECHNICAL DATA

Air Eliminators and Combination Air Eliminators Strainers

The Discussion of this exercise covers the following points: Pumps Basic operation of a liquid pump Types of liquid pumps The centrifugal pump.

Features. General application. Technical data

Pumping Systems for Landscaping Pumps, Controls and Accessories. Mark Snyder, PE

TUTORIAL. NPSHA for those who hate that stuffy word. by Jacques Chaurette p. eng. copyright 2006

PREVIEW COPY. Table of Contents. Basic Pumping Concepts...3. Maintaining Packing and Seals Lesson Three Maintaining Centrifugal Pumps...

4400 TwinHybrid Gas Seal

Goulds 3296 EZMAG. Chemical Process Pump

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

Exercise 4-2. Centrifugal Pumps EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Pumps

Ball Float Steam Trap UNA 43 PN 16/CL 125/JIS 10K UNA 46 PN 40/CL 150/CL 300/JIS 10K/JIS 20K DN 80, 100, 150, 3", 4", 6"

Installation, Operation and Maintenance Manual for Back Pressure Regulator

PIP RESP73H Application of ASME B Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process

Meter, PD Series, E3 A1, S1 and E4 S1 Prior to 2005 Parts List

E.2 Series. High efficiency circulator. Technical overview

Берг АБ Тел. (495) , факс (495) Turning Ideas Into Engineered Solutions KAYDON RING & SEAL, INC.

SECTION BUTTERFLY VALVES

DANFLO Control Valves 400 Series Model 20

STAINLESS STEEL GRAND SERIES

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

A soft sealed atmospheric safety valve with large flow capacity and soft seat tightness for steam condenser and turbine applications

Liquid ring compressors

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Installation Instructions

R-1450 R6. Safety Relief Valve

MUELLER. Mega-Lite Drilling Machine. Reliable Connections. table of contents PAGE. Equipment 2. Operating Instructions 3-4. Parts Information 5

VISI-FLO Sight Flow Indicators

Meter, PD Series, E3 S6, S7 All Parts List

DISASSEMBLY AND ASSEMBLY INSTRUCTIONS FOR LIQUID RING COMPRESSORS

SpeciÞcations. Engine Dimensions Dimensions in millimeters. Inch equivalents shown in [].

FACHGESPRÄCH 3 NPSH NPSH3. Let us call it: CAVITATION A LOOK UNDER THE HOOD

DUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS

Installation Instructions

Centrifugal Pump Intro

Installation Operation Maintenance

Suggested Installation & Operating Instructions for Sidewinder Pumps

Tradition & Technology

Corken, a tradition of excellence

TECHNICAL DATA Q= C. Table 1 - Specifications

Meter, PD Series, E3 S1 and E4 S to Present Parts List

PRODUCTS CATALOGUE 2017 / Torino - Strada Settimo 388/15 Tel (+39) /43 Fax (+39)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Offshore Equipment. Yutaek Seo

shutoff valves 900 Series psig Manual Shutoff Valves

Models 461-S, 461-8S and S Regulators. R-1330 Rev. 7

Crosby style JCE Safety Valve Installation, Maintenance and Adjustment Instructions CROSBY

Pneumatic Powered - Plunger Pumps

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

TECHNICAL DATA. Q = C v P S

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

SERIES 30. Spring Operated Tank Blanketing Valve PROTECTOSEAL.

2 Available: 1390/08/02 Date of returning: 1390/08/17 1. A suction cup is used to support a plate of weight as shown in below Figure. For the conditio

Maximum Pressure Differential and Maximum Inlet Pressure for Various Soft-Seated Valve Materials* Introduction. Body Pressure Ratings

North American Simplex Basket Strainers for Gas and Oil

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

PNEUMATIC PRESSURE CONTROLLERS

T208VR Series Tank Blanketing Vacuum Regulator

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06

Goulds 3198 PFA Teflon -Lined Process Pumps

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

EXH. Specifications. Descriptions. Min. working pressure MPa

Liquid ring compressors

Team Insert Valve Sample Specification The Insert Valve shall conform to the following:

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

VB-7263 Series. Application. Features. Applicable Literature

MZT PUMPI PUMP YOUR WAY TO SUCCESS MULTISTAGE CENTRIFUGAL PUMPS - MS,DMS,MSTD,MSS

PRESSURE REGULATORS UPSTREAM DIFFERENTIAL PRESSURE. APPLICATION: For maintaining a constant differential pressure across meter.

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump. WIL E-10 Replaces WIL E-09

Series C8/CR Cryogenic

TECHNICAL DATA. Q= Cv S

Homestead Series 820 AWWA Butterfly Valves

4x6x10M. 6x8x12M GPM CUBIC METERS PER HOUR. 8x10x20S. 8x8x17. 6x8x17M. 8x10x17S. 10x12x14. 6x8x12XL. 8x10x12L. 4x6x12A. 6x8x12M. 6x8x12S.

Installation Instructions

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

Installation Instructions

PRESSURE REGULATOR PRESSURE REDUCING. APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure

Registration form PUMPS AND MOTORS $ plus tax 48 HOUR RUSH ORDER PROCESSING FEE ADDITIONAL $ Address. City State Zip.

CHAPTER 3 : AIR COMPRESSOR

RW series. Clogless impeller-fitted centrifugal pumps

Ford Service Saddles and Tapping Sleeves

OHIO GEAR REDUCERS DESIGN FEATURES

Irrigation &Hydraulics Department lb / ft to kg/lit.

ANDERSON GREENWOOD TANK BLANKETING REGULATORS

Bushing Viton O-ring (Other material available) Anti-Static Device

Telefon (+45) Telefax (+45)

Page - CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 ITEM QUANTITY FOR MODEL 302

Ball Float Steam Trap UNA 45 MAX, UNA 46 MAX, UNA 46A MAX PN 40/Class 300 DN 40, 50, 65

12 Impeller Replacement

Transcription:

Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series

HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL HEAD FEET 3500 RPM 60 HERTZ 300 200 2X2X10 1 1 /2X1 1 /2X8 3X3X10 4X4X10 80 60 40 TOTAL HEAD METERS 2900 RPM 50 HERTZ 20 php Self Primer - 4 Pole 0 0 200 300 400 500 600 700 800 900 CAPACITY U.S. GPM 3500 RPM 60 HERTZ 1750 RPM CAPACITY M 3 /HR 1450 RPM 50 HERTZ 180 25 50 75 125 160 35 TOTAL HEAD FEET 1750 RPM 60 HERTZ 140 120 80 60 40 2X2X10 1 1 /2X1 1 /2X8 3X3X10 4X4X13 1 /2 4X4X10 30 25 20 15 10 TOTAL HEAD METERS 1450 RPM 50 HERTZ 20 5 Maximum Allowable Working Pressure 0 200 300 400 500 600 700 CAPACITY U.S. GPM 1750 RPM 60 HERTZ 300 PUMPING TEMPERATURE C -50 0 50 150 200 250 300 2000 WORKING PRESSURE PSIG 250 200 150 50 Minimum Temperature Limit -20 F Class 50 (316SS) Class 22 (Ductile Iron) php2110 & php2140 0-0 200 300 400 500 600 PUMPING TEMPERATURE F 3 1800 1600 1400 1200 1000 800 600 400 200 0 WORKING PRESSURE KPa

Dean Pump Series php Self-Priming Chemical Pumps Capacities to 700 GPM (160 m 3 /hr) Heads to 400 feet (120 m) Pumping temperatures to 500 F (260 C) Working pressures to 275 PSIG (1,896 kpa) Principles of Operation A self-priming pump is one in which the impeller, operating in the priming liquid, removes the air from the pump suction line. This results in a vertical rise of the process fluid in the suction line from a source below the pump. Once sufficient air is thereby removed, the process fluid flows into the pump and the pump primes. The vertical rise of the liquid is called lift. The removal of air from the suction piping permits pressure, acting on the liquid surface of the source tank, to push the process fluid up into the pump. Usually the source is at atmospheric pressure, which provides a theoretical lift of 34 feet at sea level; however, the practical lift limit is 20 feet. If the liquid in the source tank is at such an elevated temperature that vacuum pulled in the suction line causes the liquid to flash to vapor in the suction line, the pump cannot prime. A self-priming pump requires liquid in the casing to achieve the priming action. An initial prime is accomplished by filling the pump casing with liquid through the priming hole in the top of the casing. The pump is then started and allowed to prime. The pump may be turned off and reprimed thereafter with the liquid retained in the special pump casing. The action inside the pump during priming is one of air entrainment and larger bubbles passing with the priming liquid through the upper volute educer passage. The air separates out of this liquid in the upper chamber of the casing. This liquid returns to the entry port in the lower volute section and is recycled back into the impeller. This action continues until sufficient air has been expelled to allow the pump to prime. Once prime is established, the pump operates just like a standard centrifugal pump. During the priming cycle, there must be no air leaks in the suction piping or the shaft sealing device. Leakage of air into the system may prevent the pump from achieving prime. When the pump prime is broken, the liquid in the suction pipe flows back into the liquid suction source. There may be a siphon effect, greater or lesser, depending on height, liquid and velocity. Although this pulls more liquid from the casing, there is always sufficient liquid retained in the php casing to start the priming cycle again. Thus, repriming can occur. A self-priming pump is not a cure for an NPSH problem. The NPSH required by the pump is necessary for the pump to continue operating. A self-priming pump will handle occasional periods of vapor or air and will recover, but the NPSH required by the pump must be provided. This will depend upon the amount of lift required and the vapor pressure of the fluid being pumped. Priming Time Calculation Determine the effective suction lift. (Multiply vertical suction lift by specific gravity). Refer to the priming time curves. Using the effective suction lift, enter the priming time curve, read across to the impeller diameter selected and down to the priming time. This is the priming time if the suction line is the same size as the suction flange and is all vertical lift without horizontal component. To correct priming time for a different size of suction line and/or horizontal piping, use the formula below: t pc t p L t L v D d = corrected priming time in seconds = priming time from curve = total length of suction pipe above the liquid surface in feet = vertical height from surface of liquid to centerline of pump = diameter of suction pipe, nominal, in inches = pump suction size, nominal, in inches t pc = t p ( L t/l v ) ( D /d) 2 EXAMPLE Assume: Vertical lift (L v ) = 20 feet Total length of suction pipe (L t ) = 40 feet Priming time (t p ) = 42 seconds Suction line D = 4 nominal diameter Suction flange d = 3 nominal diameter Then: t pc = 42 ( 40 /20) ( 4 /3) 2 = 149.3 seconds Heating of priming liquid can reduce the maximum lift, but usually the NPSH above the vapor pressure requirement for the L v 2

operating point has long been exceeded. The heating of the priming liquid is of the magnitude of 10 F per minute. EFFECTIVE STATIC LIFT Ft (STATIC LIFT X S.G.) 25 20 15 10 5 To illustrate: 3 x 3 x 10, php2140, 3550 rpm, full diameter Lift of 20 feet in 3 pipe Water @ 80 F From the priming time curve for the 3 x 3 x 10, php2140, the priming time is 32 seconds. PRIMING TIME SEC. IMP. DIA. 10" 9" 8" Priming at 20 feet requires an absolute pressure at the pump eye to be (34 feet 20 feet), or 6.06 psia. From the steam tables, water boils at this pressure at about 170 F. The allowable maximum temperature rise in the priming liquid is (170 F - 80 F), or 90 F. At a temperature rise of 10 F per minute (60 seconds) the pump could run for nine minutes (540 seconds). Putting this time back into the priming time formula gives: t pc = t p ( L t/l v )( D /d) 2 540 sec. = 32 sec. ( L t/20)( 3 /3) 2 540 sec. (20) (1) Max. L t = 32 Max. L t = 337 ft. 3550 RPM 0 10 20 30 40 50 60 EFFECTIVE STATIC LIFT M (STATIC LIFT X S.G.) Insure that max. L t actual L t In applying a self-priming pump, consideration of the discharge piping is necessary. The air from the pump casing must be expelled without being compressed substantially above atmospheric pressure. Although a self-priming pump will prime against a small discharge pressure, the priming time will increase. However, if the pressure in the discharge line is too high, the pump will not achieve prime. If the pump expels air into an empty discharge system, there is more than adequate volume available to contain the discharged air. If the discharge line contains a check valve, the check valve should be placed a minimum of one half times L t away from the pump discharge to provide adequate volume, provided that the suction and discharge lines are the same size as the flanges on the pump. Caution should be taken to insure that the available volume in the discharge line is at least 50% of the suction line volume to be evacuated. Another priming solution would be to install a valved line from the pump discharge system back to the suction source. This is left open during the priming cycle and closed when priming is accomplished and during pumping. With this arrangement, a check valve must be installed in the pump discharge line downstream of the bypass connection. 18 6 4 2 4 MECHANICAL DESIGN SPECIFICATIONS PUMP TYPE php2110 php2140 Direction of Rotation (Viewed from Coupling End) CW CW Horsepower Rating @ 3500 rpm 35 HP 100 HP @ 1750 rpm 15 HP 40 HP @ 1150 rpm 10 HP 30 HP Hydrostatic Test Pressure Class 22-50 430 psig 430 psig Corrosion Allowance 1/8" 1/8" Impeller Balance Single Plane Dynamic Balance Flanges ANSI Class 150 150 Facing standard F.F. F.F. optional R.F. R.F. Finish 125 Ra 125 Ra Stuffing box jacket pressure maximum 125 psig 125 psig Bearing housing cooler pressure maximum 125 psig 125 psig Maximum Suction Pressure 275 psig 275 psig Bearings: Thrust Bearing 5306 5309 Radial Bearing 6207 6309 Lubrication Oil Oil Seal Chamber Dimensions: Tapered Seal Chamber Length (Depth) 2 3 /8" 3 1 /16" Inside Diameter (Bore) 2 7 /8" 3 1 /2" Shaft Sleeve Diameter 1 3 /8" 1 3 /4" Cylindrical Seal Chamber Length (Depth) 1 7 /8" 2 1 /4" Inside Diameter (Bore) 2 7 /8" 3 1 /2" Shaft Sleeve Diameter 1 3 /8" 1 3 /4" Stuffing Box Dimensions: Length (Depth) 2 1 /8" 2 3 /4" Inside Diameter (Bore) 2" 2 1 /2" Shaft Sleeve Diameter 1 3 /8" 1 3 /4" Lantern Gland Width 7/16" 5/8" Packing Size Square 5/16" 3/8" Number of Rings with Lantern Ring 5 5 Number of Rings without Lantern Ring 6 7 Spacing with Lantern Ring 2-G-3 2-G-3 Pump Shaft Dimensions: Span Between Bearings 3 15 /16" 6 3 /8" Span Between Radial Bearing and Impeller 5 13 /16" 7 7 /8" Diameter Under the Sleeve 1 1 /8" 1 1 /2" Diameter with No Sleeve 1 3 /8" 1 3 /4" Diameter at Coupling 7/8" 1 1 /8" Diameter Between Bearings 1 1 /2" 2 1 /8" Diameter at Impeller 3/4" 1 1 /4" L 3 /D 4 Ratio Sleeved Shaft 123 96 Solid Shaft (No Sleeve) 55 52 STANDARD MATERIALS OF CONSTRUCTION PART NO. PART NAME DUCTILE IRON 316SS 3 Impeller C.I. (1) 316SS (12) 5 Casing D.I. (10) 316SS (12) 5A Casing Drain Plug 1020 Steel 316SS 5D Casing Capscrew Steel (11) 7 Cradle Spacer 1 D.I. (13) 7G Spacer to Brg. Hsg. Capscrew 1 1020 Steel 9 Bearing Housing Foot 1 C.I. (1) 10 Shaft Sleeve 316SS 10K Sleeve Key 304SS 13 Seal Chamber Gland Steel 316SS 14 Gland Stud 304SS 15 Gland Nut 304SS 17 Lantern Ring Teflon 22 Casing Back Cover D.I. (10) 316SS (12) 22A Back Cover to Cradle Capscrew 1020 Steel 25 Radial Bearing 25A Thrust Bearing 26 Bearing Housing D.I. (13) C.I. (1) 27 Seal Ring 1 C.I. (1) 28 Bearing End Cover C.I. (1) 28A Bearing End Cover Capscrew 1020 Steel 28B End Cover Adjusting Screw 1020 Steel 28C Adjusting Screw Locking Nut 1020 Steel 29 Pump Shaft Steel (5) 31 Thrust Bearing Lock Nut 1 1020 Steel 31A Thrust Bearing Lock Washer 1 1020 Steel 75A Tapered Retaining Ring 2 Steel 75B Large Retaining Ring Steel 76 Labyrinth Seal Front Bronze & Viton 76A Labyrinth Seal Rear Bronze & Viton 77 Casing Gasket Teflon 77A Impeller Gasket Teflon 77B End Cover Gasket Buna (7) 80 Vent 95A Mechanical Seal Stationary 95B Mechanical Seal Rotary 109 Oil Cooler Assembly SS Tubing with Steel Fins and Steel Fittings 1 php2140 only Denoted parts are interchangeable in all ph2110 and php2110 pumps 2 php2110 only Denoted parts are interchangeable in all ph2140 and php2140 pumps Registered Trademark of the E.I. DuPont Company (1) Cast Iron (11) Steel: ASTM #A449 (5) Alloy Steel: 125,000 TS, 100,000 YP (12) 316SS: ASTM #A744 Grade CF-8M (7) Buna N Rubber (13) Ductile Iron: ASTM #A536 (10) Ductile Iron: ASTM #A395

php2110 php2140 5

Dimensions with Economy Baseplate PUMP SIZE DISCHARGE SUCTION SIZE O.D. THICKNESS B.C. BOLTS SIZE O.D. THICKNESS B.C. BOLTS 1 1 /2 x 1 1 /2 x 8 1 1 /2 5.688 3.88 4 1 /2 1 1 /2 5.688 3.88 4 1 /2 2 x 2 x 10 2 6.750 4.75 4 5 /8 2 6.750 4.75 4 5 /8 3 x 3 x 10 3 7.50.938 6 4 5 /8 3 7.50.938 6 4 5 /8 4 x 4 x 10 4 9.938 7.50 8 5 /8 4 9.938 7.50 8 5 /8 4 x 4 x 13 1 /2 4 9.938 7.50 8 5 /8 4 9.938 7.50 8 5 /8 PUMP SIZE D M S T T 1 X Y CP HL 1 1 /2 x 1 1 /2 x 8 8.25 2.50 4.0 8.0 6.75 10 6.0 13.25 10.75 2 x 2 x 10 10 2.50 6.0 7.50 6.25 12 6.50 19.5 4.5 3 x 3 x 10 10 3 6.0 8.63 6.25 13 7 19.5 4.5 4 x 4 x 10 11.50 5 6.0 11.75 7.56 13 8 19.5 4.5 4 x 4 x 13 1 /2 11.50 5.50 6.0 11.75 9.50 16 7.50 19.5 4.5 FRAME C AB HA HB HD D=8.25 D=10 D=11.5 HG HM 143T 13.25 6.50 12 45 12.0 13.75 15.25 3.75 3.88 145T 13.75 6.50 12 45 12.0 13.75 15.25 3.75 3.88 182T 14.63 7.50 12 45 12.0 13.75 15.25 3.75 5.25 184T 15.63 7.50 12 45 12.0 13.75 15.25 3.75 5.25 213T 18.13 9.50 12 45 12.0 13.75 15.25 3.75 6 215T 19.63 9.50 12 45 12.0 13.75 15.25 3.75 6 254T 23.13 11.00 15 52 12.38 14.13 15.63 4.13 7 256T 24.88 11.00 15 52 12.38 14.13 15.63 4.13 7 284T 26.88 12.63 15 52 14.13 15.63 4.13 7.75 284TS 25.50 12.63 15 52 12.38 14.13 15.63 4.13 7.75 FRAME C AB HA HB HD D=8.25 D=10 D=11.5 HG HM 286T 28.38 12.63 15 52 14.13 15.63 4.13 7.75 286TS 27.00 12.63 15 52 12.38 14.13 15.63 4.13 7.75 324T 29.88 14.75 18 58 14.75 16.25 4.75 8.75 324TS 28.38 14.75 18 58 13.0 14.75 16.25 4.75 8.75 326T 31.38 14.75 18 58 14.75 16.25 4.75 8.75 326TS 29.88 14.75 18 58 14.75 16.25 4.75 8.75 364T 33.13 16.25 18 58 14.75 16.25 4.75 9.88 364TS 31.50 16.25 18 58 14.75 16.25 4.75 9.88 365TS 32.50 16.25 18 58 14.75 16.25 4.75 9.88 All dimensions are in inches. 6040 Guion Road Indianapolis, IN 46254 P: 317.293.2930 TOLL-FREE: 800.801.9265 F: 317.297.7028 info@deanpump.com www.deanpump.com 2010 MET-PRO CORPORATION DEAN PUMP IS A REGISTERED TRADEMARK OF MET-PRO CORPORATION 09-5912 810