COLD WATER STORAGE CONTROL AYLESBURY TM FLOAT VALVE RANGE

Similar documents
COLD WATER STORAGE CONTROL AYLESBURY DELAYED ACTION FLOAT-ACTIVATED VALVES

Specification Catalogue

TANKTRONIC. STANDARD CONFIGURATION Single Tank. ADVANCED CONFIGURATION Multiple Tanks. Twin Tank (common valve) Twin Tank (separate valves) Vent box

DESIGN AND PRE - INSTALLATION INFORMATION

k valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN): tel fax

KAX VALVE ¾ (20) 1 (25) 1¼ (32) 1½ (40)HF 2 (50)SF INSTALLATION GUIDE AYLESBURY FOR VALVE SIZES (DN):

KERAFLO. Guide to the UK Water Supply Regulations. The AylesburyTM Float Valve Range. ..%1111.1mr - In%

k valve ½ (15) ¾ (20) 1 (25) 1¼ (32) 1½ (40)HF 2 (50)SF installation guide aylesbury For valve sizes (DN):

Float Valve Function and Design Considerations

AYLESBURY 'KB' TYPE FLOAT VALVES

SINGLE VALVE WITH LOW-FLOW BYPASS

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

TECHNICAL DATA. Low-Flow Foam Preaction System with Hydraulically Actuated Concentrate Control Valve.

Water Regulations Tutorial # 3 Filling Heating Systems

POP Safety Valve. POP Safety Valve INTRODUCTION DEFINITIONS

TECHNICAL DATA. than the water inlet pressure to the concentrate

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

BERMAD Waterworks. Level Control Valve. with Bi-Level Vertical Float. 700 Series. Major Additional Features. Features and Benefits.

AutoChanger Installation & User Guide Issue 2

BERMAD Fire Protection Hydraulic Control Valves

SCA Series Inverted Bucket Steam Traps

BACK PRESSURE / SUSTAINING

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Manual Actuated Boiler Blowdown Valves

BACK PRESSURE / SUSTAINING

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

Hydraulic Valve Installation Guide

Unit 24: Applications of Pneumatics and Hydraulics

Summary of Substantive Changes between the 2012 and 2018 editions of CSA B125.3 Plumbing Fittings

Wet pipe low flow foam/water system

776 Cryogenic Safety Valve

Pilots Specifications

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

M45 ISO Ball Valve DN25 to 150 Installation and Maintenance Instructions

The Next Generation for Level Control. By Ryan Spooner, Singer Valve

Liquid Level Controllers

Rate of Flow Valve Series 120

Expert Hydrostatic Level Transmitters

CAST IRON VALVES FLOAT VALVE

Agpro. Flush Valves TECHNICAL DATA / SPECIFICATIONS / APPLICATION GUIDE

Digester Processes. 1. Raw Sludge Pumping System

BEFORE SALES AFTER SALES

KBV21i and KBV40i Air Actuated Boiler Blowdown Valves

756 Safety Relief Valves

553 Series.

Blowdown vessels Meeting the requirements of HSE PM60

SV5 Safety Valve Installation and Maintenance Instructions

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

P r o d u c t R a n g e Data sheet: P

DESIGN DATA A WET PIPE BLADDER TANK FOAM/WATER SYSTEM WITH HYDRAULICALLY ACTUATED DELUGE CONCENTRATE CONTROL VALVE

GROUTEC SCOTT VICKERS. Grouting Equipment

Pressure & Flame Protection

The Future of Hydraulic Control in Water-Systems

BSA6T and BSA64T Stainless Steel Bellows Sealed Stop Valves Installation and Maintenance Instructions

AE50S Automatic Air and Gas Vent for Liquid Systems Installation and Maintenance Instructions

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

A3S Bellows Sealed Stop Valve Installation and Maintenance Instructions

SRI Jigger Tubes System

Precision Liquid Settlement Array Manual

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

300 Series. Automatic Hydraulic Control Valves

TECHNICAL DATA. TRIMPAC Model B-5 & B-5B

Thermocirc Installation and Maintenance Instructions

HM and HM34 Inverted Bucket Steam Traps Installation and Maintenance Instructions

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

System Pressure Manager Standard & System Pressure Manager Plus

Installation, commissioning and servicing instructions

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

Pressure Independent Control Series

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

DN300 DN2000 C Plunger Valve

Installation, commissioning and servicing instructions

S300 Series. Valve Link. Features. Fisher Controls

High Performance BSP Dial Up Pattern Pressure Reducing Valve

Variable Area Flow Meters

Installation, Operation and Maintenance Instructions for Pacific PA Non-Storage Heat Exchanger

CALEFFI. Ball zone valves. series /03 GB

Hydraulic Valve. Installation guide. Please keep this booklet for future reference.

B L A C K H A L L. larner-johnsonvalve presentation

MSC-P and MSC-N Manifolds for Steam Distribution and Condensate Collection

Red Valve Coarse and Fine Bubble Air Diffuser Systems

TECHNICAL DATA. Trimpac 257a. September 16, 2013

INSTALLATION, OPERATING & MAINTENANCE MANUAL WATER DRAIN VALVE

TD45 Thermodynamic Steam Trap Installation and Maintenance Instructions

TECHNICAL DATA. Trimpac 256a. October 31, 2013

Spirax Compact FREME Flash Recovery Energy Management Equipment

The Shand & Jurs Model Vapor Guard Tank Blanketing Valve

Installation, Operation and Maintenance Instructions for Mild Steel Buffer Vessel

Lecture 10 : Sewer Appurtenances

1. General safety information. 2. General product information. 3. Installation. 4. Commissioning. 5. Operation. 6. Maintenance. 7.

AE30 Automatic Air Eliminators / Air and Gas Vents for Liquid Systems

PumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

ABB MEASUREMENT & ANALYTICS DATA SHEET. AP100 ph/redox (ORP) cartridge sensors with water-wash option

TSS21 Sealed Thermostatic Steam Tracer Trap

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

TECHNOLOGIES. M Series. Positive return metering pumps [API675]

BIO GAS STORAGE TANKS. for each Plant Design. Long service life. Maintenance free set-up. Permanently gas-tight. Quickly installed

Transcription:

COLD WATER STORAGE CONTROL AYLESBURY TM FLOAT VALVE RANGE

Keraflo have manufactured top quality, delayed action float valves in the UK for over 30 years. The Aylesbury TM range is synonymous with float valve excellence with tens of thousands of products in continual use in demanding domestic, commercial and industrial applications throughout the UK and around the world. The Aylesbury TM Float Valve Range Aylesbury valves are designed to provide an accurate and efficient method of controlling the level of stored cold water in tanks with and without raised float valve chambers. Manufactured in the UK in a Lloyd s Register Quality Assured manufacturing facility, they are constructed to operate over long periods without the need for maintenance. In addition all valves are WRAS approved and come with a 5 year warranty. The valves are easy to install with an up and over discharge arrangement which assists in facilitating Type AA, AB, AF, or AG air gap requirements under the Water Regulations. The Aylesbury range is ideal for pumped systems as the open to closed on/off valve operation avoids pump hunting and water hammer. The set water level is unaffected by pressure fluctuation and there is no seat or washer to wear. The Aylesbury Delayed Action Float Valve Range Non adjustable opening / closing operating differential of approximately 75mm. K Type age 4 KAX Type age 5 Fully variable opening and closing operating differential of up to 1820mm and longer on request. KB Type age 6 K Type age 8 2

AYLESBURY VALVES Benefits of Keraflo s Aylesbury Float Valve Range Maintenance Free: Designed to operate for long periods without maintenance. Backsiphonage rotection: Up and Over discharge to BS1212 part 2 helps to facilitate Air Gap compliance. Extended Durability: Non-wearing ceramic disc seal in a DZR brass housing. Virtually Indestructible: The heart of the valve incorporates pressure compensated rotating ceramic discs which are aligned in the open position. Revolutionary Shaped uncture roof Float: Made from olyethylene closed cell foam which is CFC free air retardant and chemically and biologically inert. This radical design virtually eliminates stress on the tank wall fixing point. Water ressure: Suitable for 0-10 Bar. Temperature Range: 1-60 C. n Ideal for pumped systems n Reduces Legionellae risk n No valve bounce n No dribble n No water hammer n Improves water turnover n Saves energy with positive pump control n Maximises tank capacity n Fixed & variable level differential models n Full flow during fill 3

The Aylesbury K Type - Delayed Action Float Valve - Suitable for tanks without raised valve chambers The weighted key-shaped float which is supplied with Aylesbury K Type float valves can be accurately set in a number of positions on the brass float arm, actuating the valve at a predetermined difference in water level, driving it fully open or fully closed without water hammer. This positive action avoids dribble, reduces noise and allows full flow until the selected closed level is reached. CLOSED OSITION OEN OSITION FIXED DELAYED ACTION OENING LEVEL Inherent in the design is a non-adjustable operating differential in water level between opening and closing of approximately 75mm. Also available in stainless steel for use in demanding environments such as desalination plants and sea water. Sizes for K Type Delayed Action Float Valve 1 2 (15mm) 3 4 (20mm) 1 (25mm) 1 1 4 (32mm) 1 1 2 (40mm) 2 (50mm) Standard Flow (SF) High Flow (SF) Standard Flow (SF) High Flow (SF) Reduced Bore 2 (50mm) 2 1 2 (65mm) 3 (80mm) Larger sizes, opposite handed and stainless steel available on request 4

AYLESBURY VALVES Aylesbury KAX Type - Delayed Action Float Valve - rimarily for tanks with raised valve chambers Identical in operation to the K Type, the Aylesbury KAX Type Valves have extended drops and are suitable for raised valve chambers. They are primarily designed to fit into chambers or boxes in the covers of tanks calling for Air Gaps or where maximum tank capacity is required. CLOSED OSITION OEN OSITION To assist with compliance of Air Gap requirements the valve discharge is further raised above the centre line. The KAX is especially suitable for Type AA & AB Air Gaps. FIXED DELAYED ACTION OENING LEVEL Sizes for KAX Type Delayed Action Float Valve 3 4 (20mm) 1 (25mm) 1 1 4 (32mm) 1 1 2 (40mm) 2 (50mm) Standard Flow (SF) High Flow (SF) Standard Flow (SF) High Flow (SF) Reduced Bore 2 (50mm) 2 1 2 (65mm) 3 (80mm) Larger sizes, opposite handed and stainless steel available on request 5

The Aylesbury KB Type - Fully Variable Delayed Action Float Valve - Suitable for tanks with or without raised valve chambers The valve is operated by a transfer of weight in an actuator tube which causes the valve to open or close. The arrangement of the float and buoy assembly produces a delayed change of balance in the actuator as the water level alters. The total assembly is relatively light with no pressure related stresses. As a result the valve does not require any supporting structure. Aylesbury KB Type valves have a variable delayed action and feature a chain in place of a rigid float arm enabling virtually unlimited opening and closing levels. This allows for a considerable drop from the valve to the water level, overcoming issues associated with drop arms. The versatility of the Aylesbury KB Type makes it suitable for installation either directly into a tank or into a raised valve chamber particularly where Air Gaps are required. Changes in water levels and differentials can be made quickly by the installer or maintenance engineer without tools. This feature is particularly useful where water demand changes either due to seasonal factors, building occupancy or where the commissioning of a facility is phased, as it reduces the risks associated with excess water being stored for too long. Sizes for KB Type Delayed Action Float Valve 3 4 (20mm) 1 (25mm) 1 1 4 (32mm) 1 1 2 (40mm) 2 (50mm) 2 1 2 (65mm) 3 (80mm) Standard Flow (SF) High Flow (SF) Reduced Bore (RB) Larger sizes, opposite handed and stainless steel available on request 6

AYLESBURY VALVES The Aylesbury KB Type Applications This unique valve is ideal for use with pumped systems, water treatment plants and many other applications including: n Industrial tanks n umped systems n Underground tanks n Rain (grey) water tanks and reservoirs n Industrial feed and expansion tanks n rocess tanks For more information on the applications, call our technical support team or visit www.keraflo.co.uk/applications The flexibility of KB valves can assist with improving water quality where buildings are partially commissioned or occupancy varies, at different times of the year. Air Gaps for Industrial Tanks The KB Type is ideal for fitting into a tank without a lid or raised valve chamber and where the vertical drop from the valve to the water level may be considerable. umped Systems The adjustable and potentially large difference between opening and closing levels can allow a large volume of water to be admitted to the tank each filling cycle. umps and pump sets are often controlled to run for a minimum of 3 minutes. If the water demand is satisfied before this time and an auxiliary hydraulic accumulator is not fitted, the pumps will run against a closed valve at zero efficiency. The fill volume can be set to equal or exceed this volume to ensure the pump/s run for at least 3 minutes. Where a pump set is used solely for transferring water from a break tank to an elevated storage tank the KB Valve can dispense with the need for an auxiliary hydraulic accumulator. CLOSED OSITION OEN OSITION ump efficiency and initial sizing can be further enhanced using a float valve with little internal resistance. Consequently the High Flow version is often better suited to these applications than the Standard Flow version which is ideal for mains water pressure applications. CLOSING FLOAT FULLY VARIABLE DELAYED ACTION OENING BUOY OENING LEVEL 7

Aylesbury K Type Float Valve Kit - Fully Variable Delayed Action Float Valve - Suitable for tanks with or without raised valve chambers The K Type Float Valve Kit comprises an in-line control valve together with an Aylesbury KB Type Valve acting as a pilot. The pilot valve offers fully variable delayed action opening and closing water level settings making this ideal for mains or pumped systems. High Kv Value The standard K Control Valve offers excellent flow rate performance. Raised Valve Chamber Can be small as it only has to accommodate a ¾ KB valve and discharge assembly. Facilitates Air Gaps ILOT VALVES The Aylesbury KB Valve is supplied with a 2m long adjustable chain as standard allowing the closing level to be set below any combination of Weir Slot, Overflow and/or Warning Device. Quiet Operation Aylesbury valves are quieter than conventional valves due to the elimination of Water Hammer, Valve Bounce, Hiss and Dribble. Accessibility An externally mounted Control Valve can be easily - inspected, adjusted and if required serviced. Re-chlorination of the tank is not necessary provided the tank lid is not removed. CONTROL VALVE Optional Extra n Upstream ressure Sustaining Regulator - the Control Valve regulates itself to leave the desired minimum upstream pressure (Adjustable 1-6 Bar). This can also be used to provide a constant flow rate. Sizes for K Type Fully Variable Delayed Action Float Valve Kit 1 1 2 (40mm) 2 (50mm) 2 1 2 (65mm) 3 (80mm) 4 (100mm) 6 (150mm) 8 (200mm) Larger sizes, opposite handed and stainless steel available on request 8

AYLESBURY VALVES Aylesbury K Type Float Valve Benefits n No Water Hammer n Full Flow During Fill n Maximises Tank Capacity n Maintenance Free n No backing plate required n No Valve Bounce n No Dribble n Delayed Action n Tank Wall Stress negligible n Ideal for Fire Sprinkler Systems n Suitable for all types of Air Gap applications Flexibility and ease of Installation Conventional Float Valves above 3 are heavy and cumbersome often necessitating a two person installation. When the K Control Valve is mounted outside the tank at floor level, no heavy lifting is required. The Control Valve can be mounted in one of four positions: n Vertically in the pipe work (preferred option) n Outside the tank at floor level n Outside the tank above the tank water level n Inside the tank above the tank water level Multiple Discharges To reduce the risk of stagnation, two or more discharges can be connected to the outlet of the control valve. Since the Filling ipe is only subjected to low pressure, thin wall VC pipe can be used. The K Valve can also be configured to service twin/partitioned tanks. OVERFLOW ILOT VALVE WARNING IE Shallow Tanks K Valves can operate in tanks as shallow as 1 metre in depth. REFERRED ALTERNATIVE (VERTICAL) MOUNTED ORIENTATION OENING LEVEL Deep Tanks The standard Aylesbury KB ilot valve enables an opening level 2m below the inlet level. A longer chain can be supplied if required. OUTLET CONTROL VALVE 9

K Typical Standard Tank Installation ALTERNATIVE OSITION FOR CONTROL VALVE OUTSIDE OR INSIDE CHAMBER DISCHARGE ASSEMBLY ILOT VALVE ILOT ISOLATING VALVE (SULIED) OVERFLOW WARNING IE DELAYED ACTION REFERRED ALTERNATIVE (VERTICAL) MOUNTED ORIENTATION OENING LEVEL ILOT LINE OUTLET SERVICING VALVE (SULIED) CONTROL VALVE SERVICING VALVE (NOT SULIED) K Typical Twin Tank Installation DISCHARGE ASSEMBLY ILOT VALVE ILOT ISOLATING VALVES (SULIED) ILOT VALVE DISCHARGE ASSEMBLY OVERFLOW OVERFLOW OENING LEVEL OENING LEVEL OUTLET OUTLET ISOLATING VALVE (SULIED) ISOLATING VALVE (SULIED) SERVICING VALVE (NOT SULIED) SERVICING VALVE (SULIED) CONTROL VALVE 10

AYLESBURY VALVES Specification Support Keraflo s National Sales Team provide the very highest levels of technical advice and specification support at local level, including guidance regarding Water Regulations compliance. Water Regulations Keraflo s 20 page Guide to the Water Supply Regulations highlights the design implications of this legislation with regard to float valves. This highly informative A4 document explains Air Gap types, fluid categories of risk and explains in detail the system design implications of the most common Air Gap types. COLD WATER STORAGE CONTROL UK WATER SULY A GUIDE TO REGULATIONS A copy of this Guide is available on request or may be downloaded from our website. CD Seminars Keraflo offers a CD seminar presentation entitled UK Water Regulations which addresses a range of specification issues including back flow protection and their implications on float valves. To enquire about these seminars please contact us. Downloadable CAD & DF roduct Drawings and Fitting Instructions A wide range of Keraflo product drawings are available on request or may be downloaded in DF or CAD format from our website, www.keraflo.co.uk. Keraflo and Aylesbury are registered trade marks. The Aylesbury valve is a patented product. Keraflo Ltd reserve the right to alter designs without prior notice. 11

TANKTRONIC DIGITAL TANK MANAGEMENT Main Control Unit Tanktronic monitors water levels and temperature. It can also manage and control tank filling, enabling users to vary tank capacity to match demand. S-Module An expansion module that boosts Tanktronic s control capacity. Additional pilot valves and 3rd party devices can be connected to the system. Sensor The Sensor monitors both water pressure and temperature. The unit is provided pre-fitted to a vent box for rapid mounting and wiring connection. Keraflo Limited, Unit 1, Woodley ark Estate, 56-69 Reading Road, Woodley, Reading, Berkshire, RG5 3AN, UK 0118 921 9920 info@keraflo.co.uk www.keraflo.co.uk A subsidiary of Davidson Holdings Ltd.