Pressure Sensor PSE54#

Similar documents
Pressure Sensor PSE53#

Pressure Sensor for General Fluids PSE56#

Technical Specifications

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Industrial Filter. FGD series

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Air operated valve. VGA342R Series

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Lightweight and Compact Type Floating Joint

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Related Products: Auto Drain Valve. Model/Specifications. Model

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

5 Port Air Operated Valve

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

IR1000-A IR1010-A IR1020-A

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Series AMJ. Drain Separator for Vacuum

Series IRV1000/2000/3000

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

5 Port Solenoid Valve

Filter-Regulator-Lubricator

Parallel Seal Type Slit Valve

Pressure Sensor/ PSE57 /PSE300AC Series CAT.ES A. 3-Screen Display Sensor Monitor. 500 VAC <Twice that of the PSE560> Remote Type

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

reduces flow setting time and setting errors!

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Vacuum Pad with Ejector. Series ZHP

Pilot Check Valve: Metal Body Type

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Moisture Control Tube

Operation Manual Air Saver Unit ASV5000 Series

Compact Pressure Switch

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Pressure Sensor/ PSE57 /PSE300AC Series. 3-Screen Display Sensor Monitor 500 VAC. Remote Type. Change the settings while checking the measured value.

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

Precision Regulator IR3120

Coiling Tube with Twist-Proof Fitting

Compact Pressure Switch

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Electro-Pneumatic Converter YT-940 SERIES

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

High Vacuum L Type Valve PRODUCT NAME. XLF Series MODEL/ Series

Process Pump PB1000A

Push-In Fitting Type Pressure Gauge

INSTALLATION & MAINTENANCE INSTRUCTIONS

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Push-In Fitting Type Silencer

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Dual Solenoid Gas Valve Installation

Multistage Ejector Series ZL

Multistage Ejector Series ZL

Insert Ring. Protection Ring from Tube Deformation. Protect tubes from deformation. Ultra soft tube is connectable to Fitting.

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Pre-filter for Brushless Blower Instruction Manual

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

(1) Name of tube (2) Tube dia. (O.D./I.D.) (3) Tube length. (4) Tube color. Model UD0425. UD1290 O.D. I.D. (mm) UD1075 UD0860 UD

Tube Cutter with Measuring tape built-in

PVC Quick Drain Valve

F.R.L. Units Precautions 1 Be sure to read this before handling.

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

Pressure Gauge Series

Air preparation filter

Push-In Fitting Type with Stop Valve

IRV Series. Vacuum Regulator. New RoHS. New and Improved. Series IRV10/20

SPECIFICATIONS ATTENTION

Norrsken Family Booklet

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Compact Manometer. Pressure measurements can easily be taken any time, anywhere.

VACUUM REGULATORS CONTENTS

MoveRoll Conveyor Operating and Maintenance Manual

DPS-400 SERIES DPH-100 SERIES

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

100C Air Compressor Kit

Filter-Regulator-Lubricator

Manual Actuated Boiler Blowdown Valves

200 PSI COMPRESSORS - MODEL NUMBERS

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

MODELS (2 foot Version) (4 foot Version)

Anti-spatter Tube. Spatter-Proof Tube for Pneumatic Piping. Polyamide type Tube Coated with Flame-Retardant Resin(Equivalent to V-0 )

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

accidents which arise due to non-observance of these instructions and the safety information herein. SPECIFICATIONS

PSE Series. Remote Type Pressure Sensors/Pressure Sensor Controllers PSE550 ISE70 PS ISA3 ISA2 ISE35 PSE IS ISG ZSM1

Tube for Clean Environment Polyurethane Tube Clean-Room Package

Static dissipative Resin (Surface Resistivity : 10 4 ~10 7 Ω).

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

IMPORTANT SAFETY INSTRUCTIONS

Transcription:

PRODUCT NAME Pressure Sensor MODEL / Series / Product Number PSE54#

Table of Contents Safety Instructions 2 Model Identification and how to order 8 Definition and terminology 8 Mounting and Installation 9 Wiring 9 Troubleshooting 11 Specification 12 Specifications 12 Dimensions 14-1-

Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger". They are all important notes for safety and must be followed in addition to International standards (ISO/IEC) *1) and other safety regulations. *1) ISO 4414: Pneumatic fluid power -- General rules relating to systems ISO 4413: Hydraulic fluid power -- General rules relating to systems IEC 60204-1: Safety of machinery -- Electrical equipment of machines (Part 1: General requirements) ISO 10218-1: Manipulating industrial robots -Safety. etc. Caution : Warning : Danger : CAUTION indicates a hazard with a low level of risk which, if not avoided, could result in minor or moderate injury. WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. Warning 1. The compatibility of the product is the responsibility of the person who designs the equipment or decides its specifications. Since the product specified here is used under various operating conditions, its compatibility with specific equipment must be decided by the person who designs the equipment or decides its specifications based on necessary analysis and test results. The expected performance and safety assurance of the equipment will be the responsibility of the person who has determined its compatibility with the product. This person should also continuously review all specifications of the product referring to its latest catalog information, with a view to giving due consideration to any possibility of equipment failure when configuring the equipment. 2. Only personnel with appropriate training should operate machinery and equipment. The product specified here may become unsafe if handled incorrectly. The assembly, operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced. 3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2. When the product is to be removed, confirm that the safety measures as mentioned above are implemented and the power from any appropriate source is cut, and read and understand the specific product precautions of all relevant products carefully. 3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction. 4. Contact SMC beforehand and take special consideration of safety measures if the product is to be used in any of the following conditions. 1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to direct sunlight. 2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the product catalog. 3. An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. -2-

Caution The product is provided for use in manufacturing industries. The product herein described is basically provided for peaceful use in manufacturing industries. If considering using the product in other industries, consult SMC beforehand and exchange specifications or a contract if necessary. If anything is unclear, contact your nearest sales branch. Limited warranty and Disclaimer/Compliance Requirements The product used is subject to the following "Limited warranty and Disclaimer" and "Compliance Requirements". Read and accept them before using the product. Limited warranty and Disclaimer 1. The warranty period of the product is 1 year in service or 1.5 years after the product is delivered. 2) Also, the product may have specified durability, running distance or replacement parts. Please consult your nearest sales branch. 2. For any failure or damage reported within the warranty period which is clearly our responsibility, a replacement product or necessary parts will be provided. This limited warranty applies only to our product independently, and not to any other damage incurred due to the failure of the product. 3. Prior to using SMC products, please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products. 2) Vacuum pads are excluded from this 1 year warranty. A vacuum pad is a consumable part, so it is warranted for a year after it is delivered. Also, even within the warranty period, the wear of a product due to the use of the vacuum pad or failure due to the deterioration of rubber material are not covered by the limited warranty. Compliance Requirements 1. The use of SMC products with production equipment for the manufacture of weapons of mass destruction (WMD) or any other weapon is strictly prohibited. 2. The exports of SMC products or technology from one country to another are governed by the relevant security laws and regulation of the countries involved in the transaction. Prior to the shipment of a SMC product to another country, assure that all local rules governing that export are known and followed. -3-

Operator This operation manual is intended for those who have knowledge of machinery using pneumatic equipment, and have sufficient knowledge of assembly, operation and maintenance of such equipment. Only those persons are allowed to perform assembly, operation and maintenance. Read and understand this operation manual carefully before assembling, operating or providing maintenance to the product. Safety Instructions Warning Do not disassemble, modify (including changing the printed circuit board) or repair. An injury or failure can result. Do not operate the product outside of the specifications. Do not use for flammable or harmful fluids. Fire, malfunction, or damage to the product can result. Verify the specifications before use. Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Do not use the product in a place where static electricity is a problem. Otherwise it can cause failure or malfunction of the system. If using the product in an interlocking circuit: Provide a double interlocking system, for example a mechanical system Check the product regularly for proper operation Otherwise malfunction can result, causing an accident. The following instructions must be followed during maintenance: Turn off the power supply Stop the air supply, exhaust the residual pressure and verify that the air is released before performing maintenance Otherwise an injury can result. Caution After maintenance is complete, perform appropriate functional inspections and leak tests. Stop operation if the equipment does not function properly or there is a leakage of fluid. When leakage occurs from parts other than the piping, the product might be faulty. Disconnect the power supply and stop the fluid supply. Do not apply fluid under leaking conditions. Safety cannot be assured in the case of unexpected malfunction. -4-

NOTE Follow the instructions given below when designing, selecting and handling the product. The instructions on design and selection (installation, wiring, environment, adjustment, operation, maintenance, etc.) described below must also be followed. Product specifications The direct current power supply to combine should be UL approved as follows. Circuit (of Class2) which is of maximum 30 Vrms (42.4 V peak) or less, with UL1310 Class2 power supply unit or UL1585 Class2 transformer. The Pressure Sensor is a approved product only if it has a mark on the body. Use the specified voltage. Otherwise failure or malfunction can result. For the details of compressed air quality, refer to ISO 8573-1, 1.1.2 to 1.6.2: 2001. This can cause operating failure. If compressed air containing condensate is used, install an air dryer or drain catch before the filter and perform drainage regularly. If drainage is not performed regularly and condensate enters the secondary side, it can cause operating failure of pneumatic equipment. If regular drainage is difficult, the use of a filter with an auto drain is recommended. Applicable fluid is air, inert gases and incombustible gases. Do not use a fluid containing chemicals, synthetic oils including organic solvent, salt and corrosive gases. Otherwise, damage to the product and malfunction can result. Check the details of the specifications before using. Use the specified measurement flow rate and operating pressure. Otherwise it can cause damage to the Pressure Sensor or inability to measure correctly. Reserve a space for maintenance. Allow sufficient space for maintenance when designing the system. Product handling Installation Tighten to the specified tightening torque. If the tightening torque is exceeded the mounting screws and brackets may be broken. If the tightening torque is insufficient, the product can be displaced and loosen the mounting screws. Be sure to ground terminal FG when using a commercially available switch-mode power supply. Do not drop, hit or apply shock to the Pressure Sensor. Otherwise damage to the internal parts can result, causing malfunction. Do not pull the lead wire forcefully, not lift the product by pulling the lead wire. (Tensile force 50N or less) Hold the body when handling to avoid the damage of the Pressure Sensor lead to cause the failure and malfunction. For piping of the Pressure Sensor, hold the piping with a spanner on the metal part of the piping (Piping attachment). Holding other part with spanner leads to damage the Pressure Sensor. Eliminate any dust left in the piping by air blow before connecting the piping to the product. Otherwise it can cause damage or malfunction. Do not insert metal wires or other foreign matter into the pressure measurement port. It can damage the Pressure Sensor causing failure or malfunction. If the entering of foreign material to the fluid is possible, install and pipe the filter or the mist separator to the inlet to avoid failure and malfunction. -5-

Wiring Do not pull the lead wires. In particular, never lift a Pressure Sensor equipped with fitting and piping by holding the lead wires. Avoid repeatedly bending or stretching the lead wire, or placing heavy load on them. Repetitive bending stress or tensile stress can cause the sheath of the wire to peel off, or breakage of the wire. If the lead wire can move, fix it near the body of the product. The recommended bend radius of the lead wire is 6 times the outside diameter of the sheath, or 33 times the outside diameter of the insulation material, whichever is larger. Replace the damaged lead wire with a new one. Wire correctly. Incorrect wiring can break the Pressure Sensor. Do not perform wiring while the power is on. Otherwise damage to the internal parts can result, causing malfunction. Do not route wires and cables together with power or high voltage cables. Otherwise the product can malfunction due to interference of noise and surge voltage from power and high voltage cables to the signal line. Route the wires (piping) of the product separately from power or high voltage cables. Confirm proper insulation of wiring. Poor insulation (interference from another circuit, poor insulation between terminals, etc.) can lead to excess voltage or current being applied to the product, causing damage. Keep wiring as short as possible to prevent interference from electromagnetic noise and surge voltage. Do not use a cable longer than 10 m. Wire the DC(-) line(blue) as close as possible to the power supply. When analog output is used, install a noise filter (line noise filter, ferrite element, etc.) between the switch-mode power supply and this product. Environment Do not use the product in area that is exposed to corrosive gases, chemicals, sea water, water or steam. Otherwise failure or malfunction can result. Do not use in a place where the product could be splashed by oil or chemicals. If the product is to be used in an environment containing oils or chemicals such as coolant or cleaning solvent, even for a short time, it may be adversely affected (damage, malfunction, or hardening of the lead wires). Do not use in an area where surges are generated. If there is equipment which generates a large amount of surge (solenoid type lifter, high frequency induction furnace, motor, etc.) close to the Pressure Sensor, this may cause deterioration or breakage of the internal circuit of the Pressure Sensor. Avoid sources of surge generation and crossed lines. The product is CE marked, but not immune to lightning strikes. Take measures against lightning strikes in the system. Mount the product in a place that is not exposed to vibration or impact. Otherwise failure or malfunction can result. Prevent foreign matter such as remnant of wires from entering the Pressure Sensor. Take proper measures for the remnant not to enter the Pressure Sensor in order to prevent failure or malfunction. Do not use the product in an environment that is exposed to temperature cycle. Heat cycles other than ordinary changes in temperature can adversely affect the inside of the product. Do not expose the product to direct sunlight. If using in a location directly exposed to sunlight, shade the product from the sunlight. Otherwise failure or malfunction can result. Keep within the specified fluid and ambient temperatures range. The fluid and ambient temperatures should be 0 to 50 C. Operation under low temperature leads to cause damage or operation failure due to frozen moist in the fluid or air. Protection against freezing is necessary. Air dryer is recommended for elimination of drain and water. Avoid sudden temperature change even within specified temperature. Do not operate close to a heat source, or in a location exposed to radiant heat. Otherwise malfunction can result. -6-

Adjustment and Operation Do not short-circuit the load. If using the product to detect very small pressure rates, warm up the product for 20 to 30 minutes first. There will be a drift on the analog output of approximate ±1% immediately after the power supply is turned on, within 10 minutes. Maintenance Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of air before performing maintenance. There is a risk of unexpected malfunction. Perform regular maintenance and inspections. There is a risk of unexpected malfunction. Perform drainage regularly. If condensate enters the secondary side, it can cause operating failure of pneumatic equipment. Do not use solvents such as benzene, thinner etc. to clean the Pressure Sensor. They could damage the surface of the body and erase the markings on the body. Use a soft cloth to remove stains. For heavy stains, use a cloth soaked with diluted neutral detergent and fully squeezed, then wipe up the stains again with a dry cloth. -7-

Model Indication and how to order Option Description Part number Remarks Connector for pressure sensor controller ZS-28-C 1 pc. Definition and terminology F O Terms F.S. (full span/full scale) Output impedance Meaning Abbreviation for full span and full scale; means the maximum fluctuation range of the Pressure switch rated value. For example, when the output voltage is 1 to 5[V], the F.S. will be 5-1 = 4[V]. (Reference: 1%F.S. = 4 0.01 = 0.04[V]) The resistance value of a component between the voltage outputting element and the output line at the output of the analog voltage output. It is indicated as a resistance value which is converted in accordance with the condition in which resistance is directly connected to the voltage output element. There may be an error in the output voltage depending on this output impedance and the input impedance of customers' equipment. (Example: If the Pressure switch with output impedance of 1kΩ is connected to the A/D converter to detect the analog output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(MΩ)/(1(kΩ) + 1(MΩ)) 4.995(V), and there is an error of approximate 0.005 V.) R Rated pressure range Repeatability Ripple The pressure range in which the Pressure switch satisfies the specifications. Values over this range can be set if they are within the set pressure range, but cannot assured the specifications to be satisfied. Reproducibility of the displayed value for pressure and ON-OFF output operating point when the pressure changes at a temperature of 25 o C. A type of chattering. -8-

Mounting and Installation Wiring Attaching the connector to the lead wire Sensor wire is stripped as shown in the right figure. Do not cut the insulation. The core of the corresponding color shown in the following table is put into the pin of the number stamped on the connector for sensor connection to the back. Pin No. Wire color 1 Brown (DC+) 2 NC 3 Blue (DC-) 4 Black (IN: 1 to 5 V) It checks that the above-mentioned preparation work has been performed correctly, and A part shown in right figure is pushed by hand and makes temporary connection. A part center is straightly pushed in by tools, such as pliers. Re-use cannot be performed once it connects the connector for sensor connection completely. When you fail in the connection mistake of a core and a pin, or the plug of wire, please use the new connector for sensor connection. When connecting the connector to PSE200/PSE300 series, please use the connector for sensor lead wire (ZS-28-C) or as below. Maker Model No. Sumitomo 3M 37104-3101-000FL Tyco Electronics 1-1473562-4 OMRON XN2A-1430 Please contact with each connector maker about catalogue. Connector and applicable pressure sensor Connecting/Disconnecting When connecting the connector, insert it straight onto the pin holding the lever and connector body between fingers and lock the connector by pushing the lever claw into the square groove in the housing until connector clicks. When disconnecting the connector, push down the lever by thumb to disengage the lever claw from the square groove. Then pull the connector straight out. PSE200 series PSE300 series -9-

Internal circuit and wiring example Output specification Voltage output: 1 to 5 V Output impedance: Approx. 1 kω -10-

Troubleshooting Cross-reference for troubleshooting Problem Possible cause Investigation method Countermeasure Incorrect wiring Check if the analog output line is connected with a load. Correct the wiring. Analog output is not provided. (Specified accuracy is not satisfied.) Non-compliance with the load spec. Insufficient warm-up (1) Check if the proper load is connected. (2) Check if input impedance of input equipment (A/D transformer) is proper. Check if the product satisfies the specified accuracy in 20 minutes after supplying power. Connect a proper load. After energizing, indication and output can drift. For detecting fine pressure, warm up the product for 20 to 30 minutes. Product failure Replace the product. Noisy. Air and liquid leakage Check if air liquid are leaking from the piping. Rework the piping. If excessive tightening torque over the specified range is applied, a mounting screw, mounting bracket, and product may be broken. Product failure Replace the product. -11-

Specification Specifications Model No. PSE540(A) PSE541(A) PSE543(A) Rated pressure range 0 to 1 MPa 0 to -101 kpa -100 to 100 kpa Extension analog output range -0.1 to 0 MPa 10.1 to 0 kpa - Withstand pressure 1.5 MPa 500 kpa Applicable Power supply voltage Current consumption Output specification Air, inert gases and incombustible gases 12 to 24 VDC±10%, ripple (p-p) 10% or less (Protected against inverse connection) 15 ma or less Analog output: 1 to 5 VDC (with rated pressure range) 0.6 to 1 VDC (with extension analog output range) Output impedance: Approx. 1 kω Accuracy (Ambient temperature at 25 o C) PSE54#: ±2%F.S. (with rated pressure range) ±5%F.S.(with extension analog output range) PSE54#A: ±1%F.S.(with rated pressure range) ±3%F.S.(with extension analog output range) Linearity ±0.7%F.S. ±0.4%F.S. Repeatability ±0.2%F.S. Power supply voltage effect ±0.8%F.S. Enclosure IP40 Environ ment Ambient temperature range Ambient humidity range Withstand voltage Insulation resistance Temperature characteristic Standard Operation: 0 to 50 o C, Storage: -20 to 70 o C (No condensation or freezing) Operation, Storage: 35 to 85%RH (No condensation) 1000 VAC or more, 50/60 Hz, 1 minute, Between lead block and case 50 MΩ or more at 500 VDC Between lead block and case ±2%F.S. (25 o C reference) CE, UL/CSA, RoHS Piping specifications Model No. M3 M5 01 N01 R04 R06 IM5 IM5H Port size M3x0.5 M5x0.8 R1/8 M5x0.8 NPT1/8 M5x0.8 φ4 reducer φ6 reducer M5 female thread, through type M5 female thread, through type (with mounting hole) Material Case Pressure sensing section Resin case: PBT Fitting: SUS303 Resin case: PBT Fitting: C3604BD PBT Pressure sensor: Silicon, O-ring: NBR Resin case: PBT Fitting: A6063S-T5 Sensor cable Oil resistance vinyl cabtyre cable 3 cores 2.7x3.2 3 m Sectional area of conductor: 0.15 mm 2 Outside diameter of insulator: 0.9 mm Mass With sensor cable Without sensor cable 42.4 g 42.7 g 49.3 g 41.4 g 41.6 g 43.3 g 44.1 g 2.9 g 3.2 g 9.8 g 1.9 g 2.1 g 3.8 g 4.6 g -12-

Analog output Range Rated pressure range A B C For vacuum 0.0 to -101 kpa 0-101 kpa 10.1 kpa For compound -100 to 100 kpa -100 kpa 100 kpa - For positive pressure -0 to 1 MPa 0 1 MPa -0.1 MPa -13-

Dimensions M3 PSE54 (A)- M5 PSE54 (A)-M3 PSE54 (A)-M5 A 10.8 11.5 B 3 3.5 01 PSE54 (A)- N01 R04 PSE54 (A)- R06 PSE54 (A)-R04 PSE54 (A)-R06 A φ4 φ6 B 18 20 PSE54 (A)-IM5 PSE54 (A)-IM5H -14-

Revision history A: For B: Complete revision Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2010 SMC Corporation All Rights Reserved