Best Practices Pneumatics Machine & Design. Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016

Similar documents
Unit 24: Applications of Pneumatics and Hydraulics

The most common terms rating air flow capacity are ICFM, FAD, ANR, SCFM or nl/min

/ /

4-7 kw/ hp. Dual Output Compressors (Air/Nitrogen) Driving Nitrogen Forward

Air Amplifiers & SYSTEMS

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Operation Manual Air Saver Unit ASV5000 Series

OPERATION MANUAL NTF-15

Introduction to Pneumatics

Membrane modules for nitrogen and oxygen generator systems. Technology Overview ENGINEERING YOUR SUCCESS.

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Sullair Air Systems. *Assessment of the market for compressed air efficiency services. Technical report, U.S. Department of Energy, June 2001

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

CompAir provide high quality and reliable Nitrogen solutions

OPERATION MANUAL NTF-60 Plus

TECHNICAL BULLETIN DESIGNING A FUNCTIONAL COMPRESSED AIR SYSTEM

CHAPTER 3 : AIR COMPRESSOR

Pilot Check Valve: Metal Body Type

Potter Nitrogen Generators

VETROSON. OXY-GEN SYSTEMS (Oxygen Generating Systems) Question & Answer Brochure

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1


Nitrogen Advantage. Better Tire Pressure Retention. Improved Fuel Economy. Extended Tread Life. Elimination of Oxidation. Reduction in Tire Failures

Oxygen Usage Best Practice Guide

Oxygen Generating Systems Ozone Medical Welding Glassblowing Aquaculture Pulp & Paper Wastewater

Applied Compression s nitrogen generator packages offer users a cost-effective alternative to costly bottled nitrogen.

GLOSSARY OF TERMS. Adiabatic Compression Compression process when all heat of compression is retained in the gas being compressed.

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

WORKHOLDING APPLICATION BOOKLET

Industrial Compressor

TRAINING SCHEDULE FLUID POWER TRAINING CUSTOM TRAINING PRODUCT TRAINING

TECHNICAL INFORMATION

Maintenance and Troubleshooting of Pneumatic Conveying Systems for Sand in a Foundry

3M TM Versaflo TM AP-600 Series Air Filtration Panels For use with 3M TM Versaflo TM Supplied Air Respirator Systems. Work. in a World of.

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

Unit 24: Applications of Pneumatics and Hydraulics

Pressure on Demand. Air Pressure Amplifiers

Installation and User Manual

Technical Information

SPH 4C Unit 4 Hydraulics and Pneumatic Systems

Gerald D. Anderson. Education Technical Specialist

NTF-515. Operation Manual

Installation, Operation, and Maintenance Manual Parker Balston Model N2-04 Nitrogen Generator

Screw Compressors 11-22kW

Industrial Applications

Reliability: Piping Distribution & Storage Matter. Instructor: Kurt Thielemann Principal

Cable Pressurization Buffering

COMPRESSED AIR DISTRIBUTION SYSTEMS

HANDBOOK SAFETY DEVICES. Ed SAFETY DEVICES DS-ED 01/ ENG 1

COMPRESSED AIR TEXTILES ENERGY EFFICIENCY

Spring Loaded Regulators Constant Loaded Regulators Twin Parallel Flow Regulators Field Service Regulators

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

THE WATER-COOLED INDUSTRIAL RANGE

COMPRESSED AIR SYSTEMS AND ENERGY SAVINGS

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

V-Major, V-Compact. Reciprocating Compressors. Intelligent Air Technology

Breathable Compressed Air

Copyright, 2005 GPM Hydraulic Consulting, Inc.

CHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222

Simplicity in VRU by using a Beam Gas Compressor

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Related Products: Auto Drain Valve. Model/Specifications. Model

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

ON-SITE INDUSTRIAL GASES. Nitrogen & Oxygen Generators

Nitrogen Generators. PMNG Commercial Series. Section 50 Bulletin A -20

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Air Operated Hydraulic Pumping Systems to 50,000 psi

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

North American Orifice Metering System

Workshop Compressors CLASSIC Series

TECHNICAL INFORMATION

ENERGY CONSERVATION IN PNEUMATIC SYSTEMS. Solutions That Save

Portable Oil Lube Air Compressors

Getting the Most for Your Money

Advanced Management of Compressed Air Systems Pre-Workshop Assignment

GUARDIAN EQUIPMENT Emergency Eye Wash and Shower Equipment. ANSI Z358.1 Compliance Checklist

MB-SP Series Solvent Purification System

The Expanding Role of High Purity Nitrogen in Fire Protection

Flow meter. bellow vaporizer. APL valve. Scavenging system

Jupiter Type 4 Tube Owner s Manual

SERVICE MANUAL MODEL BA050BMST BREATHING AIR PANEL

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Brownie s. Commercial Series NMCS-30 NMCS NW 1st Street, Fort Lauderdale, FL PH Fx

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

Right-Angle Tube Roller Model

Air operated valve. VGA342R Series

Types 749B and R130 Changeover Manifolds

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Manual Actuated Boiler Blowdown Valves

BACK PRESSURE / SUSTAINING

Pneumatic Power Topics:

Air preparation units

Storage Systems and Accessories

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Full Range Pressure Compensating Variable Flow Control

AIRLINE-SERIES HELMET AIR FILTER

Niltox Breathing Air Purifier Range

Transcription:

Pneumatics Machine & Design Written by Richard F. Bullers, CFPPS as published in Fluid Power Journal, July/August 2016 Contents at Atmospheric Air The air at a compressor s intake contains about 78% nitrogen, 21% oxygen, 0.9% argon, and other trace gases. Most importantly, it also contains varying amounts of dust, pollen, other airborne contaminants and water. Depending on the environment, lots of dirt and water are possible. Dirt is an abrasive, and water is a solvent. They have to be removed at point of compression, and failing to do so will cause major problems. Use an after cooler with automatic drain immediately after the compressor if not built in. Use an air tank with automatic drain. This component stores energy, allowing the compressor to run cooler and less often, extending life. It also serves as a heat exchanger to eliminate additional condensate. Use a main line filter with automatic drain next in-line. Over capacity at this point is far better than under capacity. Use a refrigerated dryer with automatic drain after the main line filter. Use plumbing practices to inhibit the transmission of water and materials that inhibit the formation of corrosion. Use correct point-of-use filtration. If control of the compressed air supply is not a possibility, use addition-al filtration and automatic drains at point of use on the machine. Note an acceptable air cleanliness standard for the machine (reference ISO 8573-1) and base warranty information upon the use of clean, dry air. Compressibility and Volumes One advantage of compressing gas molecules, (i.e. air ), squeezing them together, is storage. A large quantity of potential energy can be stored in a tank. A disadvantage is the lack of 1 P age

density that makes the precise positioning of air cylinders difficult and simultaneous operation virtually impossible. Because compressed air is a soft form of energy, the correct application of volume becomes a critical performance issue when using pneumatics. Use an after cooler with automatic drain immediately after the compressor if not built in. Use a tank to store additional energy to compensate for momentary lack of supply pressure or momentary increases in flow demand. Use a main line filter with automatic drain next in-line. Over-capacity at this point is far better than under capacity. Use a tank as a buffer when air pulsations cause issues with performance of cylinders, gauges, filter life, or regulator life. When regulators are paired with small tanks, performance gains can be realized. Reduce circuit volume that compromises performance by mounting valves as close as possible to cylinders, rotary actuators, or other end effectors, but ensure enough flow capacity is available in any connectors and tubing. Do not design the use of more than one cylinder to move a common load unless the load has external guides. Multiple pneumatic cylinders cannot be accurately coordinated for speed or position. The resulting imbalanced load will accelerate wear and may cause malfunction or even a catastrophic failure. Pressure Characteristics Pneumatic pressure is expressed as a measure of force per unit of area. It literally represents the amount force created by the number of air molecules in random motion striking a surface of a known size. In the ocean of air we live inside, atmospheric pressure is approximately 14.696 pounds of force for every square inch at sea level. In pneumatic systems, the air is concentrated (compressed), so more molecules are striking the same amount of area. The safe, economical, and practical amount of pressure that should be used for an application is a primary consideration in the selection of pneumatics. Pressurized air must also be visualized as and equated to a directly proportional relationship of potential energy, kinetic energy, and money. The higher the pressure, the higher the stored energy and the energy 2 P age

turned into power, but at increasing cost. Think of all three at the same time during the design process. Use the correct load ratio for pneumatic actuators. Use only the amount of pressure required for the force needed to do the work. Use regulators with performance characteristics that meet the requirements of the application. A regulator is an on-demand valve that shuts off at the set point. Use as close as practical to the application. Use standard regulators on the supply side of a directional control valve unless otherwise noted. Size regulators in conjunction with filters by sizing the filter first. Flow Characteristics Flow is given as volume per unit of time, i.e. a cubic foot every minute (cfm or ft³/min). It is a measure of the rate that energy is being used by the end effector and is more correctly identified as flow demand. The maximum amount of flow required is the most important aspect of sizing virtually every pneumatic component upstream of the end effector and is called the peak flow demand. Each pneumatic component, whether it be fittings, tubing, flow controls, valves, regulators, filters, and so forth, is sized based upon having enough flow capacity to deliver the peak flow demand without too much lost energy. This energy loss is called a pressure drop or Delta P and is the difference in pressure between the inlet of the component and outlet of the component during flow. The actual pressure drop across a component in operation will vary due to a number of factors, so for purposes of sizing components, an ideal pressure drop is assumed for the flow capacity calculation. This assures sufficient flow capacity without under sizing or grossly over sizing the component. 3 P age

The flow capacity is expressed as a comparative and unit-less number called a Cv or as an effective area, noted as the S value in mm². Always calculate peak flow demand for each end effector in a machine. For multiple end effectors operating at the same time, peak flow demands can be summed. Size all pneumatic components based upon their flow capacity for the peak flow demand required. For tubing and piping size successively from small at point of use, to medium at transmission, to large at point of compression, sum the simultaneous peak flow demands common to each line. The longer the tubing or pipe, the less the flow capacity. Each 4-fold increase in length reduces the flow capacity by 1/2. For pneumatic logic, avoid long signal transmission lines if possible. Energy Efficiency Eliminate waste by using precision nozzles, short pulses, and close target proximity to the nozzle(s) for blow off applications. Shut off pressure to machines or processes not in operation for extended periods. Maintain and/or provide maintenance schedules for filters, regulators, lubricators, actuators, and all compressed air components. Use dual pressures. For example, a cylinder working in one direction but simply returning in the opposite should be operated with two pressures. A check type regulator or a check valve used in parallel with a regulator can be used between the cylinder and valve. Consider reducing machine or system pressure when the majority of applications are operated at lower pressures and only a few exist at higher pressures. Evaluate the use of an air pressure booster for the higher pressure requirements. 4 P age

Safety Considerations There has been a lot written about this topic, but after 35 years in fluid power, I have still seen machines that present the danger of injury. We are responsible for each other, personally, professionally, as fellow human beings. Never count on someone else to assure your safety. Never fail to account for someone else s safety in your design. Make every part of your design dummy proof because I can assure you that sooner or later some good natured, wellmeaning person will be fiddling with your machine and you will never get a decent night s sleep again if your machine causes injury. Enough said. Go to, read, and request information from www.osha.gov on safe machine design. Research, read, and review the machine design standard ISO 13849-1. Enlist help, other valued opinions, and critical analysis of any safety aspects of your design and validate them through established practices and comprehensive testing. Consider and/or employ the services of a PE (professional engineer) and/or firm specializing in safety analysis as needed for validation. Never take safety for granted, ever. 5 P age