M-System s I/P and P/I Transducers

Similar documents
Measurement And Control Appreciation

GP1 & GP2. Electropneumatic Regulators FOR PRESSURE CONTROL TO 1,000 PSI

Exercise 8. Closed-Loop Pressure Control, Proportional-Plus-Integral Mode EXERCISE OBJECTIVE

The Ins and Outs of I/P Transducers

Exercise 5-2. Bubblers EXERCISE OBJECTIVE DISCUSSION OUTLINE. Bubblers DISCUSSION. Learn to measure the level in a vessel using a bubbler.

The Discussion of this exercise covers the following points:

Liquid level instruments BM 24 /BM 51

Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

GE Oil & Gas. Mooney * Flowgrid * Slam Shut Regulator. Delivering accuracy, performance and protection

4194 Series Differential Pressure Indicating Controllers

2600T Series Pressure Transmitters Plugged Impulse Line Detection Diagnostic. Pressure Measurement Engineered solutions for all applications

Technical Manual. Liquid Level Transmitter CT801-LB/S

800 Series Mass Flow Meters and Controllers. High Performance Mass Flow Meters and Controllers

Becker Precision Equipment

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Model 4000 Pressure Controller

Process Control Loops

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Radar, Ultrasonic and RF Level Transmitters

Introduction to Pneumatics

SSL. Smart Valve Positioner.

Exercise 2-2. Second-Order Interacting Processes EXERCISE OBJECTIVE DISCUSSION OUTLINE. The actual setup DISCUSSION

ADVANCED CONTROL VALVE AND ACTUATOR: Selection, Calculations, Sizing, Applications, Operation, Diagnostic Testing, Troubleshooting and Maintenance.

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Becker Precision Equipment

TECHNICAL DATA PILOT PRESSURE REGULATED DELUGE SYSTEM CONTROLLED BY PNEUMATIC RELEASE. 1. DESCRIPTION (Refer to Figures 1, 2 or 3.

Highest Quality. Gas Chlorination Systems

Pilot HON 625. Entwurf. Product information. serving the gas industry worldwide

Model 130M Pneumatic Controller

White Paper. Electrical control valve actuators on oil and gas production separators

Control Valve : The Final Control Element. Nimish Shah

Pro-V Multivariable Flowmeter Model M22 In-line Vortex

C-Flow Coriolis Mass Flow Meters

SINGLE VALVE WITH LOW-FLOW BYPASS

Programmable pressure and temperature transmitters PTM/RS485

XMO2. Panametrics Smart Oxygen Analyzer. Applications. Features. bhge.com. An oxygen transmitter for use in:

Fisher 4194 Differential Pressure Indicating Controllers

LUGB Vortex Flowmeter

Vortex Flow Meter Wafer or Flange Connection. - Steam - Liquid - Gas

Powers Controls RC 195 Multiple Input Receiver- Controller

Phuel Portable Control Units

The Future of Hydraulic Control in Water-Systems

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

MODEL HICV-130Ti7-331N. Lot NAGOYA JAPAN PAT.

ATEX VACUUM PUMPS AND GAUGES CHEMICALLY RESISTANT, OIL-FREE AND SAFE

MACH ONE MASS FLOW CONTROLLER. MACH ONE SERIES flow control. MASS FLOW CONTROLLERS at the speed of sound.

ISQB1 INTRINSICALLY SAFE ELECTRO-PNEUMATIC CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS HAZARDOUS AREA CLASSIFICATION

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

Process Equipment Design Guidelines Chapter Four Instrumentation Selection and Sizing (Engineering Design Guidelines)

CCT-7320/ROC-2313 Reverse Osmosis Controller

Digital Level Control One and Two Loops Proportional and Integral Control Single-Loop and Cascade Control

V10K GAS FEED SYSTEM WALLACE & TIERNAN PRODUCTS

Powers Controls RC 195 Single Input Receiver-Controller

SB AXIAL FLOW VALVES

Programmable pressure and temperature transmitters PTM/RS485

GH & GHL Series Gas-Over-Oil Valve Actuators

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

Pressure management for Large

Installation and Operation Manual

CHAPTER 7: THE FEEDBACK LOOP

PROCESS MONITORING AND CONTROL

Priority (Swing) Motors Data and Specifications

Air Compressor Control System for Energy Saving in Manufacturing Plant

How to specify a product. Process Sensors and Mechanical Instruments

MITIGATING PIPE AND RISER HYDRAULIC PIPELINE ISSUES WITH THE I-RISER PLUS

Plant Air Energy Saving

INSTALLATION & MAINTENANCE INSTRUCTIONS

Float Operated Level Controllers

PositionMaster EDP300 Extended Diagnostics. Compact, well-proven, and flexible

PRODUCT CATALOG ELECTRO-PNEUMATIC PRESSURE REGULATORS & FLOW CONTROLLERS PRESSURE FLOW FORCE TENSION POSITION TORQUE VACUUM

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

ISE Subsea Tools and Toolsleds

Electro-hydraulic Proportional Flow and Direction Control Valve

Lifespan Improvements Available in the Industry

780S Ultra High Purity Series

Process Dynamics, Operations, and Control Lecture Notes - 20

STUDY OF I/P AND P/I CONVERTER

Integral type Differential pressure flowmeter VNT Series

Electropneumatic Transducer (I/P) Installation, Operation and

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

Variable Area Flow Meters

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

SSR. Smart Valve Positioner.

Level transmitters and indicators Series LU Ultrasonic level transmitter and indicator for liquids and solids

Differential Pressure Transmiter

4/2 way Pneumatic Solenoid Valve

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

DNS. Monoblock directional control valves DNS - Directional control valve

Heat Pump Connections and Interior Piping

EXPERIMENT 1 AIR PRESSURE CONTROL SYSTEM

Pressure reducing station. ARI-Pressure reducing station, self-acting or with electro-pneumatic control. ARI-PREsys -S. Pressure reducing station

EXPERIMENT 2 LEVEL CONTROL SYSTEM

Ultrasonic level transmitter and indicator

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

A versatile gas mixing system for blending LPG and air that is SAFE, RELIABLE, and EASY TO USE

How Ventilators Work. Chapter 3

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH PNEUMATIC RELEASE

Transcription:

roduct introduction and application examples 6-0023 2017-12 EC-Z654 M-System s / and s Rev. 0 01 500523 Two-wire models available with no power supply required ower Chemical plants plants Actual Size M-System has delivered a total of 165,000 units since its release of the first model. Count on us for fast and precise delivery. etroleum lants ulp & aper lants As of the end of March 2017 165,000 units Cumulative shipments www.m-system.com : 78,722 units : 86,584 units

M-System s uses the feedback of a semiconductor pressure sensor to loop configuration with / transducer: Example of flow control M-System s is an electro-pneumatic converter that uses a semiconductor pressure sensor with a built-in temperature compensation circuit. The sensor detects air pressure output as an electric signal and feeds back the signal to the input side. Compared with the conventional mechanical feedback system, this method makes it possible to obtain a much higher loop gain without being influenced by nozzle flapper and pilot valve characteristics, thus eliminating the drawback of the conventional mechanical feedback system. Single Loop ler SC Series Functional block diagram of loop powered / transducer Z Deviation amplifier nput signal S nozzle Semiconductor pressure sensor Throttle Output signal (3 to 15 psig) ilot valve Supply pressure: 140 ka (20 psig) (pneumatic type) supply Reducing valve with filter / positioner Fluid Flowmeter valve (globe valve) Japan Market Trend of neumatic Valves Applicable with s s for control valves are classified into electrical actuators and pneumatic actuators. Electrical actuators (i.e., actuators driven electrically) are characterized by their high performance, compactness, and energy-saving features, the market share of which is increasing year by year. On the other hand, because of the trust for pneumatic actuators (i.e., actuators driven pneumatically) based on long established track records, there are still many users of pneumatic actuators, the trend of which is considered to continue for a while in the future (see the graph ). We understand that / transducers will be used continuously in the future as well. But we also hear many manufacturers have now discontinued the products or they require a long delivery time. M-System has been offering s for 33 years as important auxiliary devices for pneumatic actuators, and will continue manufacturing them in the future to support the pneumatic actuator market. roduction volume of automatic valves Unit: million yen 45,000 40,000 35,000 30,000 25,000 20,000 15,000 10,000 5,000 0 2007 2010 2012 neumatic control valves Hydraulic control valves Solenoid valves Total 2014 Survey report on valve industry overview issued by the Japan Valve Manufacturers' Association 2 2015 Electrical control valves

achieve a high resolution with no positional errors. nternal structure of (Model: HVN) Semiconductor pressure sensor (Manufactured by Nidec Copal Electronics) flapper structure (image enlarged and processed to make the nozzle visible) Sensor Behavior explanation ilot valve Actual size section (actual size) drive coil Output pressure connection Supply pressure connection High air capacity up to 60 Nℓ/minute (2.1 SCFM) High precision No positional errors High-density mounting 3 Loop owered Model: HVN

Driving Valves by neumatic with neumatic ositioner Why is the / Transducer not connected directly to the actuator? nstrumentation systems employing pneumatic actuators and pneumatic positioners are still widely adopted today. A cost reduction of a system will be possible if a number of s are mounted integrally, compared with the use of field-mounted type. On-site cabinet (Collective installation) Loop owered HVN supply (neumatic type) Rack-mounted Model: 10V (24V DC powered) 10VN (loop powered) Use of a positioner will improve response speed and precision. Most control valves are provided with positioners. / / positioners are available as well, but it is said that / positioners are more robust and resistive to vibrations. / positioner Fluid Flowmeter valve Driving Valves in Hazardous Locations You can install / Transducers in non-hazardous areas. What will happen if pneumatic control valves are in a hazardous area? / 1 to 5 V DC f / positioners for hazardous locations (intrinsic safety) are not available, s are installed in the non-hazardous (safe) areas to convert electric signals to pneumatic signals. Galvanic isolator Space-saving lug-in Style Model: HV (24V DC powered) HVN (loop powered) Loop owered HVN Signal conditioner cabinet (Collective installation) They can be compactly accommodated with a mounting block into a control cabinet. supply Non-hazardous area (control ) (neumatic type) (Two-wire type) / positioner Mounting Block ( Header) Model: MB Fluid Flowmeter valve 4 Hazardous area

Application Examples Remotely Setting -mounted neumatic ndicating lers We want to use DCS to control field instruments but can we still use existing pneumatic controllers? n the case of cascade (remote) settings for field-mounted pneumatic indicating controllers from the DCS, the will convert electrical signals into pneumatic signals. / Loop owered HVN Use M-System's / Transducers for remote setting from the DCS. Capillary (neumatic type) Heat sensing element lug-in Style Model: V / positioner -mounted pneumatic indicating controller (Example: Company A's KFTA model) valve Directly Driving neumatic s The output of the directly drives a pneumatic actuator with no pneumatic positioner used. f the length of air piping is long, install a quick exhaust valve(*) for response time improvements. (*) A quick exhaust valve is an auxiliary device used to quickly discharge air that flows backward from the actuator to the air pipe on site when the output pressure of the / Transducer is reduced. A quick exhaust valve is installed at a point close to the valve and used to discharge air quickly. Single Loop ler (with batch function) SC200B We understand that M-System's / Transducer can directly drive a small valve. What is a quick exhaust valve then? / ulse/analog signal Loop owered HVN The actuator's response time is improved when there is a long piping between the / transducer and the field site. Quick exhaust valve outlet An example of the two-step closing of a control valve in batch operation Opening (neumatic type) Time Fluid Quick exhaust valve (Example: Company C's QEV-28 model) Flowmeter valve (small diameter) 5

Application Examples Retrieving Signals from Old -mounted neumatic nstruments into DCS There are many old pneumatic instruments running on site, still in good condition. t may be necessary to replace the old pneumatic instruments with electronic instruments if we want to take these signals into the DCS. Many on-site pneumatic instruments are still in operation. By converting signals from these instruments into electrical signals and interfacing to a leading-edge control system (i.e., DCS/controller), the old assets can still be effectively used. / You can solve the problem by using M-System's / Transducers to convert pressure signals from the existing pneumatic instruments. (Two-wire type) Two-wire B neumatic instrument (Example: ulp densitometer) Compact lug-in Style Model: M2 (single output) W2 (two isolated outputs) t's an economical solution for effective use of your assets. ulp fluid Retrieving Signals from -mounted neumatic ndicating Transmitters into DCS We want to use DCS to control field instruments but we also want to keep the existing pneumatic transmitters (Two-wire type) We like the existing pneumatic indicating transmitters. Their indicators are easy to read. Output signals (pneumatic signals) from on-site pneumatic indicating transmitters are converted into electrical signals and taken into a DCS or a controller for the centralized monitoring of field signals. / You can solve the problem by using M-System's s. Two-wire B ressure indication mpulse piping -mount pneumatic indicating transmitter (Example: Company Y's MC45 model) lug-in Style Model: rocess piping 6 neumatic indicating transmitters can still be useful.

The illustration below shows how the pilot valve and other major parts will work and convert a changing input signal (electrical signal) into an air pressure signal. Operation of ilot Valve This pilot valve is of non-bleed type with low air consumption. Nomenclature (in Balanced State) Structure of force motor Coil Movable core Current Fulcrum Closed Servo amplifier nput 3 iping Open Diaphragm 2 Throttle Special filter Back pressure Semiconductor ressure sensor exhaust 1 Output (3 to 15 psig) Valve ilot valve Spring When nput Signal Goes Up 4 Close the flapper iping Semiconductor ressure sensor Back pressure 5 7 6 Output (3 to 15 psig) ilot valve 3 The manipulated variable of the force motor is proportional to the deviation of the output air pressure level from the input signal level. Therefore, the input signal level and the output air pressure level are equal in the balanced state. Supply pressure 140 ka (20 psig) 5 Then the back pressure will rise and push down the diaphragm. 6 The valve plug will be pushed down together with the diaphragm, the supply air will flow from the lower part of the valve plug to the output side, and the output air pressure will rise. 7 The change in the output air pressure will be detected by the semiconductor pressure sensor and fed back to the force motor through the servo amplifier. A balanced state will occur when the input signal level and the output air Supply pressure pressure level are in agreement. 140 ka (20 psig) When nput Signal Goes Down Servo amplifier 8 When the input signal level decreases, the core of the force motor will move in the direction to open the flapper. 8 Open the flapper nput iping 9 10 9 Then the back pressure will drop and the diaphragm will be pushed up by the output air pressure. 10 When the diaphragm is pushed up, a clearance will be formed in the upper part of the valve plug, from which the output air pressure will be discharged. Semiconductor ressure sensor exhaust Output Outputair pressure 11 Output (3 to 15 psig) 2 The gap between the nozzle and the flapper is controlled by the force motor, and the manipulated variable and the back pressure are proportional to each other at a high gain. 4 When the input signal increases, the core of the force motor will push the flapper in the direction of closing the flapper. Servo amplifier nput 1 The interior of the pilot valve is divided into three chambers with diaphragms, and air flows into the upper chamber through a throttle mechanism. The inflowing air blows through the gap between the nozzle and the flapper. The air pressure received by the upper diaphragm at that time is called back pressure. ilot valve 7 11 The change in the output air pressure will be detected by the semiconductor pressure sensor and fed back to the force motor through the servo amplifier. A balanced state will occur when the input signal level and the output air pressure level are in agreement. Supply pressure 140 ka (20 psig)

lug-in Signal Conditioners Space-saving lug-in Signal Conditioners M-UNT Series H-UNT Series Mounting Block HV V 16 units 8 units 1 unit Loop owered HVN Dual-output (pneumatic and electrical) Rack-mounted neumatic Signal Conditioners High-density Signal Conditioners -UNT Series 10-RACK Series DC/neumatic Transducer S TC/neumatic Transducer TS RTD/neumatic Transducer RS otentiometer/neumatic Transducer Current Loop Supply/neumatic Transducer (with square root extractor) DN Rack-mounted DCS Signal Conditioners 18-RACK Series Card-rack Signal Conditioners 11-RACK Series 11V 10V Current Loop Supply/neumatic Transducer DS Loop owered 10VN Frequency/neumatic Transducer 11VC 18V S MS lug-in Signal Conditioners M-UNT Series Space-saving lug-in Signal Conditioners Super-mini Signal Conditioners Mini-M Series H-UNT Series Space-saving Rack-mounted Signal Conditioners Mini-MW Series H Space-saving Dual Output Signal Conditioners M2 H-RACK Series W2 G Two-wire Signal Conditioners Space-saving Two-wire Signal Conditioners Super-mini Two-wire Signal Conditioners Rack-mounted Two-wire Signal Conditioners B-UNT Series T-UNT Series B-RACK Series B Other T Equipment built-in type Two-wire Signal Conditioners 3 T Rack-mounted neumatic Signal Conditioners High-density Signal Conditioners -UNT Series 10-RACK Series neumatic nput Alarm Rack-mounted DCS Signal Conditioners Dual Channel nput/output solators 18-RACK Series 15-RACK Series Card-rack Signal Conditioners 11-RACK Series AS neumatic/frequency Converter A 10 18 neumatic/square Root Extractor FN 8 15 11 / and s MB