Air Tank for Booster Regulator Compliant with ASME Standards

Similar documents
Booster Regulator/Air Tank

Booster Regulator/Air Tank

Booster Regulator/Air Tank

Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and

Series VBA1110 to 4200

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

VBA1110 to 4200 VBA /4 (IN/OUT) 1/4

Chinese Pressure Vessel Regulations Compliant Product Air Tank for Booster Regulator

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces

Related Products: Auto Drain Valve. Model/Specifications. Model

Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and

Direct Operated Precision Regulator Modular Style. Standard Specifications

Series IRV1000/2000/3000

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Precision Regulator. Series Model Regulating pressure range Port size Page

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Pilot Check Valve: Metal Body Type

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

EXH. Specifications. Descriptions. Min. working pressure MPa

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Process Pump. PAF3000 Series/PAF5000 Series

VACUUM REGULATORS CONTENTS

Process Pump. Series PAF3000/Series PAF5000

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Air Saving Valve. Pressure Valve Flow Valve

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

How to Order. Rc NPT 1/8 1/4 3/8 1/2

ALF400 to 900, ALT-5/-9

Series AMJ. Drain Separator for Vacuum

Type 4708 Supply Pressure Regulator

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Standard Specifications

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Modular Type Regulators

Type 4708 Supply Pressure Regulator

Regulator/Modular Style AR1000 to 6000

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

ALF400 to 900, ALT-5/-9

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Clean Regulator/Fluororesin Type

IR1000-A IR1010-A IR1020-A

OWNER S TECHNICAL MANUAL

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Operation Manual Air Saver Unit ASV5000 Series

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Increase factory air pressure by up to twice as much! No need for an electrical supply!

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

PVC Quick Drain Valve

Air operated valve. VGA342R Series

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.

Coiling Tube with Twist-Proof Fitting

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Clean Speed Controller with One-touch Fitting

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Push-In Fitting Type Silencer

Air preparation units

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

Compressed Air Cleaning Filter Series

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

WHEATLEY Series 500 Swing Check Valve

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Unit 24: Applications of Pneumatics and Hydraulics

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

TECHNICAL DATA. Q = C v P S

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

RP series Rotor Pumps

TECHNICAL DATA CAUTION

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Type 4708 Supply Pressure Regulator

ALF400 to 900, ALT-5/-9

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

VERTICAL BLADDER TANK

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Manual Actuated Boiler Blowdown Valves

Transcription:

Air Tank for Booster Regulator ompliant with ASME Standards ompliant with ASME standards ASME Section VIII-Division Miniature pressure vessels: UM stamp Series Variations Tank capacity 5 L 0 L 22 L 38 L arbon steel Stainless steel ASME standards compliant safety valve included (UV stamp) Manufacturer s certificate of compliance included (FORM U-3A) INFORMATION ompact connections are possible with booster regulators. ASME standards compliant safety valve included (UV stamp) Air tank ompatible with all series There are many overseas countries, including but not limited to the U.S., which have adopted the ASME standards as their design safety standards. These products can be used in the following countries by submitting a notification of use (application) in each country. [entral and South America] Argentina, Bolivia, hile, Venezuela, Brazil, Mexico [Asia/Oceania] Malaysia, Singapore, Pakistan, Taiwan, Hong Kong, India, Philippines, New Zealand Overseas Standards ompliant Product Variations Main country/region Law Part no. Tank capacity EU E Marking/Simple Pressure Vessels Directive T-Q arbon steel 5 L/0 L/20 L/38 L hina Regulations on Safety Supervision of Special Equipment/ Simple Pressure Vessels Safety and Technical Regulations South Korea Occupational Safety and Health Act/K ertification * 2 T-X0 T-X04 arbon steel/ Stainless steel arbon steel/ Stainless steel 5 L/0 L/20 L * /38 L 5 L/0 L/20 L/38 L * Refer to the Web atalog for details about models, specifications, etc. * The capacity of the T-X04 carbon steel tank is 22 L. *2 The T-X0 is not within the coverage of the High Pressure Gas Safety ontrol Act in South Korea as the maximum operating pressure is 0.97 MPa. T-X05 5-E6

T-X05 Tank capacity Symbol Internal capacity 05 5 L 0 0 L 20 22 L 38 38 L How to Order T 05 A N E V X05 ASME Standards ompliant Product * The labels indicating compliance with ASME standards are not based on the International System of Units. Additionally, these products will be sold by SM orporation of America. Please contact SM for ordering procedures and lead times. Symbol A arbon steel (SA-44) S Stainless steel (SA-240 36) Option Symbol Nil V Option None Drain valve Specifications Thread type Symbol Thread type Nil Rc N NPT Safety valve/set pressure: 2 MPa (Accessory) * E: Safety valve is included. Model T05A/T05S T0A/T0S T20A/T20S T38A/T38S Fluid ompressed air Tank capacity [L] 5 0 22 38 Max. operating pressure [MPa] 2.0 size port size 3/4 Ambient and fluid temperature [ ] 0 to 75 Mounting Horizontal (annot be mounted to walls or ceilings.) Weight [kg] 4.5/3.2 9./8.2 5.0/3.2 20.9/20.4 TA arbon steel SA-44 (Plug for inspection port is made of carbon steel.) TS Stainless steel SA-240 36 (Plug for inspection port is made of stainless steel.) Paint TA Outside: Silver gray, Inside: Phosphate coated treatment Surface treatment TS Outside: Acid cleaning Documents included Manufacturer s certificate of compliance Operation manual Included parts Safety valve Accessory kit Options/Accessory Numbers TA(arbon steel) Model T05AN T0AN T20AN T38AN T05A T0A T20A T38A Thread type NPT Rc Accessory kit T5A-Y-3N T0A-Y-3N T20A-Y-3N T5A-Y-3 T0A-Y-3 T20A-Y-3 Safety valve T-EN T-E Drain valve T-VN T-V TS(Stainless steel) Model T05SN T0SN T20SN T38SN T05S T0S T20S T38S Thread type NPT Rc Accessory kit T5S-Y-4N T0S-Y-4N T20S-Y-4N T5S-Y-4 T0S-Y-4 T20S-Y-4 Safety valve T-EN T-E Drain valve T-VN T-V The accessory kit is a set of nos. q to r. Model T5A-Y-3N T0A-Y-3N T20A-Y-3N T5S-Y-4N T0S-Y-4N T20S-Y-4N No. T5A-Y-3 T0A-Y-3 T20A-Y-3 Description T5S-Y-4 T0S-Y-4 T20S-Y-4 Quantity q O-ring (A) (2A) w Hexagon socket head taper screwed plug (For drain port) e Hexagon socket head cap screw 4 4 (A) 4 (2A) 4 r Anchor bolt/nut 4 Keep the manufacturer s certificate of compliance in a safe place.

Air Tank for Booster Regulator ompliant with ASME Standards T-X05 Dimensions T05AN-E-X05/T05A-E-X05 T05SN-E-X05/T05S-E-X05 onnected to 0A, A Safety valve (Supplied with product) /4" Tank " Tank port " Inspection port 3/4" (With plug) T05A(N)-E-X05 /4" EXH: /4" T05S(N)-E-X05 /4" EXH: /4" Inspection port 3/4" (With plug) 63 257 (370) (307) ø 4 x ø (370) (307) ø48 4 x ø Drain valve (Option) 352 374 /4" 00 00 * Order the booster regulator separately. * The length may be longer than the specification if the plugs mounted on the tank are not tightly fitted to the ends. T0AN-E-X05/T0A-E-X05 T0SN-E-X05/T0S-E-X05 Safety valve (Supplied with product) Inspection port 3/4" (With plug) onnected to 0A, A /4" Tank " Tank port " 70 278 Inspection port 3/4" (With plug) (39) (8) /4" ø70 EXH: /4" 4 x ø /4" 498 522 Drain valve (Option) 20 80 Safety valve (Supplied with product) /4" onnected to 20A Inspection port 3/4" (With plug) Tank " Tank port " Inspection port 3/4" (With plug) 70 278 (454) (367) " ø70 EXH: " (47) (367) onnected to 22A " ø70 EXH: " 4 x ø 4 x ø (442) /4" 498 522 Drain valve (Option) 20 80 20 80 * Order the booster regulator separately. * The length may be longer than the specification if the plugs mounted on the tank are not tightly fitted to the ends. 2

T-X05 Dimensions T20AN-E-X05/T20A-E-X05 T20SN-E-X05/T20S-E-X05 onnected to 20A, 40A, 43A 305 80 Inspection port 3/4" (With plug) Tank " Tank port " Safety valve (Supplied with product) /4" Inspection port 3/4" (With plug) ø26 EXH: 4 x ø3 onnected to 22A, 42A ø26 EXH: 4 x ø3 (D) /4" 400 678 700 Drain valve (Option) * Order the booster regulator separately. * The length may be longer than the specification if the plugs mounted on the tank are not tightly fitted to the ends. 00 00 [mm] model A B D* 20A 48 394 " 40A 520 429.8 " 22A 444 394 " 469 42A 477 429.8 " 493 43A 526 429.8 " * When option G (pressure gauge) is selected T38AN-E-X05/T38A-E-X05 T38SN-E-X05/T38S-E-X05 onnected to 20A, 40A, 43A Inspection port 3/4" (With plug) Tank " Inspection port 3/4 (With plug) Safety valve (Supplied with product) /4" EXH: onnected to 22A, 42A EXH: Tank port 3/4" (D) 355 205 ø2 ø2 4 x ø3 4 x ø3 /4" 0 85 873 Drain valve (Option) * Order the booster regulator separately. * The length may be longer than the specification if the plugs mounted on the tank are not tightly fitted to the ends. The booster regulator is not subject to ASME standards. 2 2 [mm] model A B D* 20A 53 444 " 40A 570 479.8 " 22A 494 444 " 59 42A 527 479.8 " 543 43A 576 479.8 " * When option G (pressure gauge) is selected Safety Instructions Be sure to read the Handling Precautions for SM Products (M-E03-3) and Operation Manual before use.

Booster Regulator/Air Tank Series /T Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. Renewed model with pressure increase ratio 2 to 4 times (A) RoHS Heavy ARX AMR 0.6 MPa 0.3 MPa ARM Factory line ARP Booster Regulator + Air Tank 0.3 MPa ARJ AR425 to 935 IR 0.3 MPa IRV Light VEX ompressor 0.3 MPa SRH Light SRP No power supply or wiring needed There is no need to install dedicated electrical wiring. Easy installation SRF Simply install the unit in the air line. Requires far less space than installing the compressor. VHR ITV I Low heat generation Very little heat is generated because no electricity is used, and there is no impact on cylinders, solenoid valves, etc. ITVX Air-only operation PVQ Operation is safe because no electricity is used. VEF VEP VER VEA VY T AP00 Booster Regulator/Series Air Tank/Series T 92

Booster Regulator Series Improved service life Doubled Floating piston structure Grease retaining groove Except 0A, A that of the conventional model Grease retaining groove Reduced noise Reduced by 3 db compared with the conventional model Metal noise reduced by a bumper on the impact part of the switch valve Exhaust noise reduced by a highnoise reduction silencer Switching valve Floating structure Bumper Improved reliability Anti-condensation Built-in mesh filter at Prevents operation failure due to foreign matter. Mesh filter Integrated air-feeding tube with the main tube Mitigates condensation caused by cooling during exhaust expansion. ylinder tube Tie-rod guide Air-feeding tube 20A 40A Elbow silencer added (Option) Space saving when installed has been realized. Except 2A, 4A Elbow silencer /8" gauge ports Allows use of standard fittings for remote pressure monitoring, etc. Gauge ports changed from /6" to /8" (A, 2A) 0A Gauge port Air-operated type Max. operating pressure.6 MPa Fourfold pressure increase type 22A 43A A 922 42A

P.924 Pressure increase ratio Body size /4" Operation Set pressure range 0.2 to.0 MPa Handle-operated type (Direct operation) Twice 0.2 to.6 MPa (2.0 MPa) 0A-02 (0.2 to 2.0 MPa) Air-operated type (Remote operation) 0.2 to.0 MPa 2 to 4 times Handle-operated type (Direct operation) 0.2 to 2.0 MPa A-02 ARJ AR425 to 935 ARX AMR ARM ARP 20A-03 22A-03 IR IRV " VEX SRH SRP 40A-04 43A-04 (0.2 to.6 MPa) 42A-04 SRF VHR " ITV I ITVX PVQ Air Tank Series T Perfect fit with a booster regulator This is an air tank to which a booster regulator can be connected compactly. It can be used alone as a tank. The pressure vessel law is different from country to country, so as an air tank suitable to a country needs to be confirmed. Extensive product lineup To meet a variety of usage environment and pressure specifications, models are available in two materials, stainless steel 304 and carbon steel (SS400), and in four sizes ranging from 5 liters to 38 liters. P.935 VEF VEP VER VEA VY T AP00 Model Tank capacity (L) Max. operating pressure (MPa) T05A T0A T20A T38A 5 0 20 38 2.0.0 arbon steel Model Tank capacity (L) Max. operating pressure (MPa) T05S 5 T0S T20S 0 20 2.0 Stainless steel T38S 38 aution When used as a single unit (not connected with a booster regulator) and pressurized at over MPa at normal temperatures, the air tank falls under the scope of the High Pressure Gas Safety Act in Japan. 923

Booster Regulator Series How to Order RoHS Made to Order (For details, refer to page 934.) 0A 20A 40A 22A 42A 43A /4", Handle-operated type ", Handle-operated type ", Handle-operated type ", Air-operated type ", Air-operated type ", Max. operating pressure.6 MPa A /4", Handle-operated type Symbol 0A-02 A-02 40A 04 Body size Pressure increase ratio: Twice Pressure increase ratio: 2 to 4 times Thread type Note) Symbol Thread type Nil Rc F G N NPT T NPTF Note) Thread types apply to the IN,, and EXH ports of the A and to the IN,, EXH, and gauge ports of the 2A and 4A. The gauge ports of the A are Rc thread type regardless of the thread type indication. Symbol 02 03 04 Port size /4 Port size Applicable series A 2A 4A Semi-standard Symbol Semi-standard Nil Standard product Pressure unit on the product name Z Note) label and pressure gauge: psi Note) Thread type: NPT, NPTF Under the new measurement law, the pressure unit of psi on the pressure gauges cannot be used in Japan. Option Symbol Option Nil None G Pressure gauge N Silencer S High-noise reduction silencer Note) GN Pressure gauge, Silencer GS Pressure gauge, High-noise reduction silencer Note) LN Elbow silencer Note) LS Elbow high-noise reduction silencer Note) GLN Pressure gauge, Elbow silencer Note) GLS Pressure gauge, Elbow high-noise reduction silencer Note) Note) Refer to ombination of Thread Type and Options. Pressure gauge Pressure gauge Silencer Elbow silencer 20A-03 22A-03 ombination of Thread Type and Options Body size Thread Option type Nil G N S GN GS Nil 0A A F N T Nil 20A 22A F N T Nil 40A F 42A N 43A T LN LS GLN Semi-standard GLS Nil -Z 42A-04 40A-04 43A-04 Air Tank ompatibility hart Booster regulator A 2A Air tank T05A T05S T0A T0S T20A T20S T38A T38S 4A 924

Booster Regulator Series Standard Specifications Model Fluid Pressure increase ratio Pressure adjustment mechanism Max. flow rate Note 2) (L/min (ANR)) 230 000 900 000 900 0 70 Set pressure range (MPa) 0.2 to 2.0 0.2 to.0 0.2 to.0 0.2 to.6 0.2 to 2.0 Supply pressure range (MPa) 0. to.0 Proof pressure (MPa) 3.5 2.4 3 Port size (Rc) (IN//EXH: 3 locations) /4 /4 Pressure gauge port size (Rc) (IN/: 2 locations) /8 Ambient and fluid temperature ( ) 2 to (No freezing) Installation Horizontal Lubrication Grease (Non-lube) Weight (kg) 0.84 3.9 8.6 3.9 8.6 8.6 0.89 Note ) If the pressure is higher than the set pressure by the handle, excess pressure is exhausted from the back of the handle. Note 2) Flow rate at IN= = 0.5 MPa. The pressure varies depending on the operating conditions. Refer to Flow-rate haracteristics on pages 926 and 927. Options/Part No. Related Products/Part No. Mist Separator, Exhaust leaner Model Description Mist separator Exhaust cleaner For 0A-02 For 20A-03 For A-02 For 22A-03 AM2-02 AM30-03 AM4-04, 06 AM-06 For 40A-04 For 42A-04 For 43A-04 AM5-06, 0 AM-0 Note) Refer to page 935 for air tanks, page 20 for mist separators and Best Pneumatics No.6 for exhaust cleaners. Refer to the separate operation manual for the connection method. 0A-02 20A-03 40A-04 22A-03 42A-04 43A-04 A-02 ompressed air Twice 2 to 4 times Handle-operated with relief mechanism Note ) Air-operated Pressure Gauge, Silencer (When thread type is Rc or G.) Model 0A-02 20A-03 40A-04 Description 0A-F02 20A-F03 40A-F04 Pressure gauge G G27-20-0 G36-0-0 Silencer High-noise reduction silencer Elbow for silencer N S L AN20-02 ANA-02 KT-0A-8 AN30-03 ANA-03 AN40-04 ANA-04 22A-03 22A-F03 KT-22A-7 AN30-03 ANA-03 42A-04 42A-F04 G36-0-0 AN40-04 ANA-04 Note ) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories. Note 2) KT-22A-7 is a pressure gauge with fitting. (Please order two units when using with IN and.) Design Handle-operated with relief mechanism Note ) 43A-04 43A-F04 G27-20-0 AN40-04 ANA-04 A-02 A-F02 G27-20-0 AN20-02 ANA-02 KT-0A-8 Pressure Gauge, Silencer (When thread type is NPT or NPTF.) Model 0A-N02 20A-N03 40A-N04 22A-N03 42A-N04 43A-N04 A-N02 0A-T02 20A-T03 40A-T04 22A-T03 42A-T04 43A-T04 A-T02 Description : when -Z : when -Z : when -Z : when -Z : when -Z : when -Z : when -Z Pressure gauge : when Nil G27-20-0 G36-0-N0 KT-22A-7N G36-0-N0 G27-20-N0 G27-20-0 G Pressure gauge : when -Z Note 4) G27-P20-0 G36-P0-N0 KT-22A-8N G36-P0-N0 G27-P20-N0 G27-P20-0 Silencer High-noise reduction silencer Elbow for silencer N S L AN20-N02 KT-0A-8N AN30-N03 ANA-N03 AN40-N04 ANA-N04 AN30-N03 ANA-N03 AN40-N04 ANA-N04 AN40-N04 ANA-N04 AN20-N02 KT-0A-8N Note ) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories. Note 2) KT-22A-7N, KT-22A-8N are pressure gauges with fittings. (Please order two units when using with IN and.) Note 3) Under the new measurement law, the pressure unit of psi on the pressure gauges cannot be used in Japan. Note 4) Pressure unit on the pressure gauge: psi aution. System configuration The of the booster regulator has metallic mesh to prevent dust from entering the booster regulator. However, it cannot remove dust continuously or separate drainage. Make sure to install a mist separator (AM series) on the inlet side of the booster regulator. The booster regulator has a sliding part inside, and it generates dust. Also, install an air purification device such as an air filter or a mist separator on the outlet side as necessary. onnect a lubricator to the outlet side, because the accumulated oil in the booster regulator may result in a malfunction. 2. Exhaust air measures Provide a dedicated pipe to release the exhaust air from each booster regulator. If exhaust air is converged into a pipe, the back pressure that is created could cause improper operation. Depending on the necessity, install a silencer or an exhaust cleaner on the exhaust port of the booster regulator to reduce the exhaust noise. 3. Maintenance space Allow the sufficient space for maintenance and inspection. 925 ARJ AR425 to 935 ARX AMR ARM ARP IR IRV VEX SRH SRP SRF VHR ITV I ITVX PVQ VEF VEP VER VEA VY T AP00

Series 0A Flow-rate haracteristics 2 20A, 22A Flow-rate haracteristics.0 40A, 42A Flow-rate haracteristics.0 Outlet pressure (MPa).5 0.5 P =.0 MPa P = 0.75 MPa P = 0.5 MPa P = 0.4 MPa P = 0.3 MPa P = P2 Outlet pressure (MPa) 0.8 0.6 0.4 0.2 P = 0.3 MPa P = 0.5 MPa P = 0.4 MPa Outlet pressure (MPa) 0.8 0.6 0.4 0.2 P = 0.5 MPa P = 0.4 MPa P = 0.3 MPa. 0 00 300 400 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) (Representative value).04 0 400 0 800 000 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) (Representative value).04 0 0 000 0 0 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) (Representative value).05 Set point.02 Set point.02 Set point Outlet pressure (MPa).0 0.95 0.9 0.85 Outlet pressure (MPa).0 0.98 0.96 Outlet pressure (MPa).0 0.98 0.96 0.8 0.94 0.94 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) harge haracteristics harge time per 0 L t (s) 40 30 20 0 0A 0.0.2.4.6.8 2.0 Pressure increase ratio P2/P The time required to charge pressure in the tank from 0.7 MPa to 0.95 MPa at 0.5 MPa supply pressure: P2 P With the pressure increase ratio from.4 to.9, the charge time of 23 6 = 7 sec. (t) is given by the graph. Then, the charge time (T) for a 0 L tank: harge haracteristics harge time per 0 L t (s) 2 0 9 8 7 6 5 4 3 2 0.0..2.3.4.5.6.7.8.9 2.0 Pressure increase ratio P2/P 20A, 22A The time required to charge pressure in the tank from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: = 0.7 0.5 =.4 P2 0.95 =.9 P2 0.8 =.6 P2.0 = = = = 2.0 P 0.5 P 0.5 P 0.5 V 0 T = t x = 7 x = 7 (s). 0 0 With the pressure increase ratio from.6 to 2.0, the charge time of.5 3.8 = 7.7 sec. (t) is given by the graph. Then, the charge time (T) for a 00 L tank: V 00 T = t x = 7.7 x = 77 (s). 0 0 harge haracteristics harge time per 0 L t (s) 5 4 3 2 0.0..2.3.4.5.6.7.8.9 2.0 Pressure increase ratio P2/P 40A, 42A The time required to charge pressure in the tank from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: P2 = 0.8 P 0.5 =.6 P2.0 = = 2.0 P 0.5 With the pressure increase ratio from.6 to 2.0, the charge time of 3.5. = 2.4 sec. (t) is given by the graph. Then, the charge time (T) for a 00 L tank: V 00 T = t x = 2.4 x = 24 (s). 0 0 926

Booster Regulator Series 43A Flow-rate haracteristics Outlet pressure (MPa) Outlet pressure (MPa) harge time per 0 L t (s).6.4.2 0.8 0.6 0.4 0.2.08.06.04.02.0 0.98 0.96 0.94 5 4 3 2 0 0 000 0 0 20 3000 Outlet air flow rate (L/min (ANR)) Pressure haracteristics P = 0.8 MPa P = 0.7 MPa P = 0.6 MPa P = 0.5 MPa P = P2 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) harge haracteristics 43A Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) Set point (Representative value) 0.0..2.3.4.5.6.7.8.9 2.0 Pressure increase ratio P2/P The time required to charge pressure in the tank from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: P2 = 0.8 P 0.5 =.6 P2.0 = = 2.0 P 0.5 With the pressure increase ratio from.6 to 2.0, the charge time of 4.5.3 = 3.2 sec. (t) is given by the graph. Then, the charge time (T) for a 00 L tank: A Flow-rate haracteristics Outlet pressure (MPa) Outlet pressure (MPa) harge time per 0 L t (s) 2 2. 2.05 2.0.95.9.85.8 400 300 00 P = 0.5 MPa P = 0.4 MPa P = 0.3 MPa 0 00 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Set point P = 0.75 MPa Inlet pressure: 0.6 MPa Outlet pressure: 2.0 MPa Flow rate: 0 L/min (ANR) 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) harge haracteristics P =.0 MPa P = P2 (Representative value) 0.0 2.0 3.0 4.0 Pressure increase ratio P2/P A The time required to charge pressure in the tank from.0 MPa to.5 MPa at 0.5 MPa supply pressure: P2.0 P2.5 = = 2.0 = = 3.0 P 0.5 P 0.5 With the pressure increase ratio from 2.0 to 3.0, the charge time of 47 58 = 89 sec. (t) is given by the graph. Then, the charge time (T) for a 0 L tank: Pulsation/Pulsation is decreased with a tank. If the outlet capacity is undersized, pulsation may occur. T05A Max. pulsation range (MPa) Max. pulsation range (MPa) 0. 0.08 0.06 0.04 0.02 0. 0.08 0.06 0.04 0.02 T05A 0 2 3 4 5 apacity (L) A T T0A, 20A, 38A T0A T20A T38A 0 0 20 30 38 40 apacity (L) T 2A 4A onditions: Inlet pressure: 0.5 MPa Outlet set pressure: MPa Flow rate: Between 0 and max. flow rate Performance of air tank Alleviates the pulsation generated on the outlet side. When air consumption exceeds air supply during intermittent operation, required air will be accumulated in the tank for use. This does not apply for continuous operation. ARJ AR425 to 935 ARX AMR ARM ARP IR IRV VEX SRH SRP SRF VHR ITV I ITVX PVQ VEF VEP VER VEA VY T AP00 V 00 T = t x = 3.2 x = (s). 0 0 V 0 T = t x = 89 x = 89 (s). 0 0 927

Series Sizing can be achieved with the SM Pneumatic System Energy Saving Program Ver. 3. Sizing ( which can be downloaded from the SM website: http://www.smcworld.com ) Tc Ts START Provide requisite conditions for selection. alculate required air flow rate Q. Select booster regulator size from flow-rate characteristics table. P P3 Necessary conditions: D [mm]: ylinder bore size L [mm]: ylinder stroke W [mm/s]: ylinder operating speed [pc.]: Number of cylinders Tc [s]: ylinder operating time Ts [s]: ylinder stop time P [MPa]: Inlet pressure P2 [MPa] Note ) : Necessary supply pressure to cylinder Example 00 00 0.5 30 0.5 0.8 Pressure Stroke Upper limit of pressure inside the tank P3 Necessary supply pressure to cylinder P2 Lower limit of pressure inside the tank P2 Inlet pressure P Note ) P2 is the necessary supply pressure to a cylinder, and set the pressure below the lower limit of pressure inside the tank with a regulator. Adjust the pressure taking the maximum operating pressure of equipment in use into consideration. Note 2) P3 is the output pressure of the booster regulator, which is also the upper limit of charge pressure to the tank. Q [L/min (ANR)] = π x D2 x W x (P2 + 0.0) x x 4 x 0 6 0.0 Q = π x 002 x (0.8 + 0.0) x x x = 84 [L/min (ANR)] 4 x 0 6 0.0 2A: Qb = 0 [L/min (ANR)] 4A: Qb = 0 [L/min (ANR)] Refer to Flow-rate haracteristics on pages 926 and 927. P2 L ød Time Other conditions: Q [L/min (ANR)]: Required air flow rate Qb [L/min (ANR)]: Outlet air flow rate of booster regulator Tc [s]: ylinder operating time K: ylinder double-acting: 2, single-acting: P3 [MPa] Note 2) : Tank charge pressure T [s]: Time to charge (Time to charge to P2) T2 [s]: Time to charge (Time to charge to P3) T [s]: Time to charge (Time to charge from P2 to P3) Z: Number of booster regulators aution Use the A (pressure increase ratio 4) with pressure increase ratio 2 to 4. Usage of pressure increase ratio below 2 is preferred for the 0A (pressure increase ratio 2). A stable operation and increased life expectancy will result. Inlet supply pressure volume is {approximately twice (pressure increase ratio 2), approx. 4 times (pressure increase ratio 4)} the volume of the outlet side. requires the inlet side volume which is the sum of the flow volume running into the outlet side and the volume exhausted from E port (for driving), because air is the power source. Judgement of flow rate NO: Need no tank The 4A can supply necessary pressure. Avoid pulsation. (Max. 0.05 MPa) NO YES The 2A cannot obtain necessary pressure. YES Obtain the tank capacity V. Select the tank capacity over V. (Q Qb/2) x (Tc x K/) V [L] = (P3 P2) x 9.9 (84 0/2) x (0.5 x 2/) V = = 4.6 [L] (.0 0.8) x 9.9 Select the T0, which can be directly connected to the 2A. Tank model T05 T0 T20 T38 Select the tank from table below. Internal capacity Applicable combination model 5 L 0 L 20 L 38 L A A 2A 2A 2A 4A 4A alculate time T from charge characteristics table. Refer to harge haracteristics on pages 926 and 927. T [s] = ( V T2 ) x T 0 Z 4.6.5 3.8 T = ( ) x = 3.5 [s] 0 Judgement of charge time T Ts NO Extend stop time Ts up to charge time T or more. NO Increase number of booster regulators (Z) to decrease T. YES YES YES 928 END When running continuously for longer periods of time, confirm the life expectancy. When the life expectancy is shorter than required, select a larger sized booster regulator.

Booster Regulator Series Working Principle The IN air passes through the check valve to booster chambers A and B. Meanwhile, air is supplied to drive chamber B via the governor and the switching valve. Then, the air pressure from drive chamber B and booster chamber A are applied to the piston, boosting the air in booster chamber B. As the piston travels, the boosted air is pushed via the check valve to the side. When the piston reaches to the end, the piston causes the switching valve to switch, so that drive chamber B is in the exhaust state and drive chamber A is in the supply state respectively. Then, the piston reverses its movement, this time, the pressures from booster chamber B and drive chamber A boosts the air in booster chamber A and sends it to the side. The process described above is repeated to continuously supply highly pressurized air from the IN to the side. The governor establishes the outlet pressure by handle operation and pressure adjustment in the drive chamber by feeding back the outlet pressure. 0A, 20A, 40A, 43A Drive Governor chamber A Booster chamber A Switching valve ircuit Example General line (low pressure) P IN (Inlet) heck valve E (Outlet) Drive chamber B Piston rod Locations requiring high pressure P2 Piston Booster chamber B Air-operated type Pilot pressure 22A, 42A When only some of the machines in the plant require high-pressure air, booster regulators can be installed for only the equipment that requires it. This allows the overall system to use low-pressure air while accommodating machines requiring high-pressure air. Plant line (source pressure) (Two-stage pressure boost) When charging a tank or the like from a source at atmospheric pressure, a circuit with a check valve can be used to reduce the charge time by allowing air to pass through the check valve up to the inlet pressure. Initially, inlet pressure (P) passes through the check valve, fills P2, and results in P = P2. Piston rod Booster chamber A Piston 0.5 MPa ø00 Operating pressure: 0.5 MPa Bore size: ø00 Output 38 N A IN (Inlet) Booster heck valve chamber B (Outlet) E Equivalent output Governor Drive chamber A Drive chamber B 0.8 MPa ø80 E IN 0.5 MPa Operating pressure: 0.8 MPa Bore size: ø80 Output 4000 N Switching valve When the actuator output is insufficient but space limitations prohibit switching to a larger cylinder diameter, a booster regulator can be used to increase the pressure. This makes it possible to boost the output without replacing the actuator. When a certain level of output is required but the cylinder size must be kept small so that the driver remains compact. When only one side of the cylinder is used for work, booster regulators can be installed only on the lines that require them to reduce the overall air consumption volume. ARJ AR425 to 935 ARX AMR ARM ARP IR IRV VEX SRH SRP SRF VHR ITV I ITVX PVQ VEF VEP VER VEA VY T AP00 Outlet pressure (MPa) P2 P Shortening time Without check valve by-pass 0 Time t (S) 929

Series Warning Design. Warning concerning abnormal outlet pressure If there is a likelihood of causing an outlet pressure drop due to unforeseen circumstances such as equipment malfunction, thus leading to a major problem, take safety measures on the system side. Because the outlet pressure could exceed its set range if there is a large fluctuation in the inlet pressure, leading to unexpected accidents, take safety measures against abnormal pressures. Operate the equipment within its maximum operating pressure and set pressure range. 2. Residual pressure measures onnect a 3-port valve to the side of the booster regulator if the residual pressure must be released quickly from the outlet pressure side for maintenance, etc. (Refer to the diagram below.) The residual outlet pressure side cannot be released even if the 3-port valve is connected to the IN side because the check valve in the booster regulator will activate. After operation is finished, release the supply pressure at the inlet. This stops the booster regulator from moving needlessly and prevents operating malfunctions. aution Mounting. Transporting When transporting this product, hold it lengthwise with both hands. Never hold it by the black handle that protrudes from the center because the handle could become detached from the body, causing the body to fall and leading to injury. 2. Installation Install this product so that the silver-colored tie-rods and cover are placed horizontally. If mounted vertically, it may result in a malfunction. Because the piston cycle vibration is transferred, use the following mounting bolts (: M5; 2, 4: M0) and tighten them with the specified torque (: 3 N m; 2, 4: 24 N m). If the transmission of vibration is not preferred, insert an isolating rubber material before installation. Mount the pressure gauge with a torque of 7 to 9 N m. aution Piping. Flushing Use an air blower to flush the piping to thoroughly remove any cutting chips, cutting oil, or debris from the piping inside, before connecting them. If they enter the inside of the booster regulator, they could cause the booster regulator to malfunction or its durability could be affected. 2. Piping size To bring the booster regulator s ability into full play, make sure to match the piping size to the port size. aution Selection. heck the specifications. onsider the operating conditions and operate this product within the specification range that is described in this catalog. 2. Selection Based on the conditions (such as pressure, flow rate, takt time) required for the outlet side of the booster regulator, select the size of the booster regulator in accordance with the selection procedures described in this catalog or model selection program. Use the A (pressure increase ratio 4) with pressure increase ratio 2 to 4. Usage of pressure increase ratio below 2 is preferred for the 0A (pressure increase ratio 2). A stable operation and increased life expectancy will result. Inlet supply pressure volume is {approximately twice (pressure increase ratio 2), approx. 4 times (pressure increase ratio 4)} the volume of the outlet side. Booster regulator requires the inlet side volume which is the sum of the flow volume running into the outlet side and the volume exhausted from E port (for driving), because air is the power source. When running continuously for longer periods of time, confirm the life expectancy. The life expectancy of a booster regulator is dependent upon the operational cycle. Thus, when used for driving cylinders, etc. in the outlet side, life expectancy will be reduced. Make sure the outlet pressure is set 0. MPa or higher than the inlet pressure. A pressure difference below 0. MPa makes the operation unstable and may result in a malfunction. 930 aution Air Supply. Quality of air source onnect a mist separator to the inlet side near the booster regulator. If the quality of the compressed air is not thoroughly controlled, the booster regulator could malfunction (without being able to boost) or its durability could be affected. If dry air (atmospheric pressure dew point: 23 or less) is used, the life expectancy may be shortened because dry air will accelerate evaporation of grease inside. aution Operating Environment. Installation location Do not install this product in an area that is exposed to rainwater or direct sunlight. Do not install in locations influenced by vibrations. If it must be used in such an area due to unavoidable circumstances, please contact SM beforehand.

Booster Regulator Series aution. Setting the pressure on the handle-operated type If air is supplied to the product in the shipped state, the air will be released. Set the pressure by quickly pulling up on the governor handle, releasing the lock, and rotating the handle in the direction of the arrow (+). There is an upper and lower limit for the handle rotation. If over-rotating the handle even after reaching to the limit, the internal parts may be damaged. If the handle suddenly feels heavy while being turned, stop turning the handle. Once the setting is completed, push the handle down and lock it. To decrease the outlet pressure, after the pressure has been set, rotate the handle in the direction of the arrow ( ). The residual air will be released from the area of the handle, due to the relief construction of the governor. To reset the pressure, first reduce the pressure so that it is lower than the desired pressure; then, set it to the desired pressure. Low SM Outlet pressure MPa (Q = 0) 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0. High 2. Setting the pressure on the air-operated type (22A, 42A) onnect the outlet pipe of the pilot regulator for the remote control to the pilot port (P). (Refer to the diagram below.) Refer to the graph below for the relationship between the pilot pressure and outlet pressure. The AR20 and AW20 are recommended for the pilot regulator. Pilot regulator The outlet pressure is twice the pilot pressure. When the inlet pressure is 0.4 MPa: Pilot pressure 0.2 MPa to 0.4 MPa Outlet pressure 0.4 MPa to 0.8 MPa IN P E Handling 3. Draining If this product is used with a large amount of drainage accumulated in the filter, mist separator or tank, the drainage could flow out, leading to equipment malfunction. Therefore, drain the system once a day. If it is equipped with an auto drain, check its operation once a day. 4. Exhaust Exhausting time from E port may be longer for a booster regulator which is set to switch in longer hour intervals. This is not an abnormal phenomenon. 5. Maintenance Life expectancy varies depending on the quality of air and the operating conditions. Signs that the unit is reaching the end of its service life include the following: onstant bleed from under the handle. Air exhaust noise can be heard from the booster regulator at 0 to 20 second intervals even when there is no air consumption on the outlet side. onduct maintenance earlier than scheduled in such cases. When maintenance is required, confirm the model and serial number of the booster regulator, and please contact SM for maintenance kit. onduct maintenance according to the specified maintenance procedure by individuals possessing enough knowledge and experiences in maintaining pneumatic equipment. The list of replacement parts and kit number are shown on page 9, and the figure shows the position of the parts. ARJ AR425 to 935 ARX AMR ARM ARP IR IRV VEX SRH SRP SRF VHR ITV I ITVX PVQ VEF VEP VER VEA VY T AP00 0 0. 0.2 0.3 0.4 0.5 Pilot pressure MPa 93

Series onstruction/replacement Parts 0A A q r e w t u r e w t q 20A, 22A, 40A, 42A, 43A t q y r w e Air-operated type q 22A, 42A Replacement Parts/Kit No. Place an order with the following applicable kit number. Model 0A 20A 40A 22A 42A 43A A Kit no. KT-0A- KT-20A- KT-40A- KT-22A- KT-42A- KT-43A- KT-A-20 The kit includes the parts from q to u and a grease pack. Model 0A 20A 40A 22A 42A 43A No. Description Quantity Piston seal 2 2 large small 2 2 Governor assembly 3 heck valve 4 4 5 6 Gasket Rod seal Mounting screw 8 2 2 8 2 7 over assembly Grease pack 2 2 The grease pack has 0 g of grease. Make sure to refer to the procedure for maintenance. 9 A each large and small 2

Booster Regulator Series Dimensions 0A-02 IN side gauge port Rc /8 A-02 IN side gauge port Rc /8 20A-03 IN side gauge port /8 40A-04 IN side gauge port /8 40 33 30 40 8.5 300 39 53 73 404 40 8.5 Pressure gauge (Option) side gauge port /8 3.2 Pressure gauge (Option) side gauge port Rc /8 3 3 Pressure gauge (Option) side gauge port /8 23 27 Pressure gauge (Option) side gauge port Rc /8 23 27 /4 port /4 7 28 Silencer (Option) 4 x ø5.5 70 EXH port /4 (When silencer installed: 07) (When high-noise reduction silencer installed: 26) /4 port /4 4 x ø5.5 7 28 70 Silencer (Option) EXH port /4 (When silencer installed: 07) (When high-noise reduction silencer installed: 26) 76 43 46 port 4 x ø2 2 28 22 22 5 98 EXH port 8 (When silencer installed: 53.5) (When high-noise reduction silencer installed: 79) 43 With elbow silencer (Option) 3 3 23 27 23 27 /4 port /4 4 x ø5.5 /4 port /4 4 x ø5.5 Silencer (Option) 24 Elbow silencer (Option) 7 28 70 (97) EXH port /4 With elbow silencer (Option) Elbow silencer (Option) 7 28 70 (97) EXH port /4 22 22 ARJ AR425 to 935 ARX AMR ARM ARP IR IRV VEX SRH SRP SRF VHR ITV I ITVX PVQ VEF VEP VER VEA VY T AP00 25 62.8 62 port 22 8 Silencer (Option) 96 6 3.2 4 x ø2 30 EXH port (When silencer installed: ) (When high-noise reduction silencer installed: 230) 933

Series Dimensions 22A-03 IN side gauge port /8 300 39 Pressure gauge (Option) side gauge port /8 59 28 Pilot port /8 39 43 46 port 2 5 Silencer (Option) 24 42A-04 IN side gauge port /8 53 73 3.2 404 40 Pressure gauge (Option) side gauge port /8 4 x ø2 98 8 EXH port (When silencer installed: 53.5) (When high-noise reduction silencer installed: 79) 85 43 Pilot port /8 72 62 62.8 port 22 8 Silencer (Option) 43A-04 IN side gauge port /8 96 6 404 40 3.2 Pressure gauge (Option) side gauge port /8 4 x ø2 30 EXH port (When silencer installed: ) (When high-noise reduction silencer installed: 230) 43 22 62 62.8 port 22 8 Silencer (Option) 96 6 3.2 4 x ø2 30 EXH port (When silencer installed: ) (When high-noise reduction silencer installed: 230) Made to Order For detailed dimensions, specifications and lead times, please contact SM. opper-free/fluorine-free 2 E explosion-proof directive (ATEX) compliant 3 Ozone resistant The inner or outer copper parts material has been changed to stainless steel or aluminum. The fluorine resin parts has been changed to general resin. 20 Standard model no. 56 Made to Order opper-free/fluorine-free For booster regulator with pressure gauge, please consult SM. This option cannot be selected for air tank with safety valve. 934 Standard model no. Made to Order E explosion-proof directive (ATEX): ategory 3GD Ozone resistance is strengthened through the use of fluororubber (diaphragm) and hydrogenated NBR (valve, rod seal) for the rubber parts of the seal material. 80 Standard model no. Made to Order Ozone resistant Weather resistant NBR (diaphragm) and hydrogenated NBR (valve) are used for the rubber parts of the standard model.

Air Tank Series T RoHS ompact connections are possible with booster regulators. It can be used alone as a tank. Also partially compatible with overseas standards T05A T20S T0S T38A aution When used as a single unit (not connected with a booster regulator) and pressurized at over MPa at normal temperatures, the air tank falls under the scope of the High Pressure Gas Safety Act in Japan. How to Order T 0 A Symbol A arbon steel (SS400) S Stainless steel 304 T 0 A F Tank internal capacity Symbol Internal capacity 05 5 L 0 0 L 20 20 L 38 38 L Symbol A Standard Product (For Japanese Market) Tank internal capacity Symbol Internal capacity 05 5 L 0 0 L 20 20 L 38 38 L E ertified Product arbon steel (SS400) Product Not Applicable to the ASME Standard Tank internal capacity Symbol Internal capacity 05 5 L 0 0 L Symbol A arbon steel (SS400) Thread type Symbol Thread type Nil Rc N NPT Note) S Note) The thread type for each port is Rc. Option Symbol Nil V Option None Drain valve Option Symbol Option Applicable model Nil None Note) All models R Safety valve T05A, T0A (Set pressure: MPa) T20A, T38A S Safety valve T05A (Set pressure: 2 MPa) T0A Note) A safety valve port is provided only when option R or S is selected. SV Q E certified product (Self-declaration document attached) Accessories Symbol Accessories Safety valve (Set pressure: MPa) RV Drain valve Safety valve (Set pressure: 2 MPa) SV Drain valve Thread type Symbol Nil F T 05 A N Thread type Rc G SV Note) Pressure unit of NPT products: psi. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) X Made to Order (For details, refer to page 937.) Applicable model T20A T38A T05A T0A Product not applicable to the ASME standard Option Symbol Option Nil None Note ) V Drain valve Note ) S Safety valve (Set pressure: 2 MPa) Note 2) Safety valve (Set pressure: 2 MPa) Note 2) SV Drain valve Note ) ustomers are responsible for preparing a safety valve. Note 2) Safety valve does not meet ASME specifications. 935 ARJ AR425 to 935 ARX AMR ARM ARP IR IRV VEX SRH SRP SRF VHR ITV I ITVX PVQ VEF VEP VER VEA VY T AP00

Series T Specifications Standard Product (For Japanese Market) Model T05 T0 T20 T38 Fluid ompressed air Tank capacity (L) 5 0 20 38 Max. operating TA 2.0.0 pressure (MPa) TS 2.0 size port size 3/4 Ambient and fluid temperature ( ) 0 to 75 Weight (kg) TA 6.6 0 4 2 TS 3.2 4.9 2 9 TA arbon steel (SS400) TS Stainless steel 304 Paint TA Outside: Silver paint, Inside: Rustproof paint TS None Note) The accessories and options are included in the same container. E ertified Product Model T05A -SV-Q T0A -SV-Q T20A -RV-Q T38A -RV-Q Fluid ompressed air Tank capacity (L) 5 0 20 38 Max. operating pressure (MPa) 2.0.0 size port size 3/4 3/4 3/4 Ambient and fluid temperature ( ) 0 to 75 Weight (kg) 6.6 0 4 2 Paint arbon steel (SS400) Outside: Silver paint, Inside: Rustproof paint Note) The accessories and options are included in the same container. Product Not Applicable to the ASME Standard Model T05A--X T0A--X Fluid ompressed air Tank capacity (L) 5 0 Max. operating pressure (MPa) 2.0 size port size Ambient and fluid temperature ( ) 0 to 75 Weight (kg) 6.6 Paint arbon steel (SS400) Outside: Silver paint, Inside: Rustproof paint Note) The accessories and options are included in the same container. Warning. Operating pressure Operate this product below the maximum operating pressure. If it is necessary, take appropriate safety measures to ensure that the maximum operating pressure is not exceeded. When the tank alone is used Use a pressure switch or a safety valve to ensure that the maximum operating pressure is not exceeded. 2. onnection onnect a filter or a mist separator to the side of the tank. Because the inner surface of the tank is untreated, there is a possibility of dust flowing out to the outlet side. A booster regulator can be connected directly with the tank accessories as indicated combinations below. Air tank T05A T05S T0A T0S T20A T20S T38A T38S aution Design A 2A 4A Selection onsider the operating conditions and operate this product within the specification range. When using the air tank with a booster regulator, refer to Sizing on page 928 or SM Pneumatic System Energy Saving Program. Mounting aution. Accessories Refer to the operation manual regarding combining booster regulators with older model air tanks. The accessories are secured by bands to the feet of the air tank. Once removed, make sure not to lose them. 2. Installation Install the tank away from people. It is dangerous if the accumulated air inside the tank were to seep out. Do not mount the air tank on a moving part or a place with vibration. When connecting a booster regulator with the tank, refer to the operation manual first, which is provided with the air tank before assembling. To mount the air tank on a floor surface, use the four holes to secure the tank with bolts or anchor bolts. List of Air Tank for Overseas ountry/region Law High Pressure Gas Safety ontrol Act Occupational Safety and Health Act Exportable models : arbon steel : Stainless steel T05A-X0 T0A-X0 T20A-X0 T05S-X0 T0S-X0 T20S-X0 T38S-X0 South Korea T38A-X0 T05A-SV-X02 Singapore, T0A-SV-X02 Factory Act Malaysia T20A-RV-X02 T38A-RV-X02 Thailand, Taiwan No applicable standard Standard product Details Exempted product Max. operating pressure: 0.97 MPa Product complies with ASME specifications JBA (Japan Boiler Association) certification attached Option (Order it separately.) T-K (Safety valve) T-V (Drain valve) Maintenance Warning. Inspection The use of pressure vessels could lead to an unexpected accident due to external damage or internal corrosion caused by drainage. Therefore, make sure to check periodically for external damage, or the extent of internal corrosion through the port hole. An ultrasonic thickness indicator may also be used to check for any reduction in material thickness. 2. Draining If this product is used with a large amount of drainage, the drainage could flow out, leading to equipment malfunction or corrosion inside the tank. Therefore, drain the system once a day. 936

Air Tank Series T Options/Accessories/Part No. <Standard Product> For TA (arbon Steel) Model T05A- T0A- T20A- T38A- Accessory kit Safety valve (When selecting an option) Note ) 2) Drain valve (When selecting an option) For TS (Stainless Steel) Model T05S- T0S- T20S- T38S- Accessory kit T5S-Y-4 T0S-Y-4 T20S-Y-4 Drain valve (When selecting an option) T-V <E ompliant Product> Model T05A-SV-Q T0A-SV-Q T20A-RV-Q T38A-RV-Q Accessory kit Safety valve Drain valve Safety valve Drain valve T5A-Y-3 T0A-Y-3 T-R (Set pressure: MPa), T-S (Set pressure: 2 MPa) T-V Drain valve T-V 58 (LOSE) to 63 (OPEN) T5A-Y-2 T0A-Y-2 T-S (Set pressure: 2 MPa) <Product Not Applicable to the ASME Standard> Model T05A--X T0A--X ø30 IN PORT /4 9 20 PORT /8 Safety valve T-R, T-S 52 T-V ø8.5 65 22 (Width acrass flats 9) T20A-Y-3 T-R (Set pressure: MPa) Note ) The set pressure of the safety valve cannot be changed. Note 2) The safety valve is a safety measure that protects the tank from excess pressure. The valve opens automatically when the specified pressure is reached, releasing excess pressure inside the tank. The valve closes again when the pressure drops below a designated value. Select a pressure valve appropriate for the maximum operating pressure specification of the tank. T20A-Y-2 T-R (Set pressure: MPa) T05AN--X T0AN--X Thread type Rc NPT Accessory kit T5A-Y-3 T0A-Y-3 T5A-Y-3-X T0A-Y-3-X Safety valve (When selecting an option) Drain valve (When selecting an option) T-S (Set pressure: 2 MPa) T-V T-SN (Set pressure: 2 MPa) T-VN The Accessory Kit is a Set of Nos. q to r. (For E ompliant Product: ty) Model T5A-Y-3 T0A-Y-3 T20A-Y-3 T5A-Y-2 T5S-Y-4 T0S-Y-4 T20S-Y-4 No. Description q O-ring Hexagon socket head taper screwed plug w (For drain port) Hexagon socket head e cap screw r Anchor bolt/nut t Bushing assembly Hexagon socket head taper screwed plug y (For safety valve port) Made to Order opper-free/fluorine-free Made to Order opper-free/ Fluorine-free Symbol 05 0 20 38 4 20 T 0 A Tank internal capacity Internal capacity 5 L 0 L 20 L 38 L (A) (2A) 4 (A) 4 (2A) V With drain valve Symbol A arbon steel (SS400) S Stainless steel 304 4 4 Quantity 4 T0A-Y-2 (A) (2A) 4 (A) 4 (2A) T20A-Y-2 For detailed dimensions, specifications and lead times, please contact SM. Note ) The thread type for each port is Rc. Note 2) A stainless steel fitting and a drain valve are included in the same container as accessories. (For detailed dimensions, please contact SM.) A safety valve cannot be selected. Note 3) Since neither copper nor fluorine parts are used for the tank, a standard model can be used when options (safety valve and drain valve) are not necessary. 4 4 937 ARJ AR425 to 935 ARX AMR ARM ARP IR IRV VEX SRH SRP SRF VHR ITV I ITVX PVQ VEF VEP VER VEA VY T AP00

Series T Dimensions: Standard Product (For Japanese Market) T05A : arbon steel onnected to 0A, A Tank port Rc Tank Rc Spare port Rc 63 257 (370) (307) Rc /4 ø56 EXH: Rc /4 4 x ø 338 349 Rc /4 00 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. T0A : arbon steel onnected to 0A, A Tank Rc Spare port Rc Rc /4 EXH: Rc /4 Tank port Rc 70 278 (39) (8) ø80 4 x ø onnected to 20A Tank Rc Spare port Rc 4 47 Rc Rc /4 20 80 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. onnected to 22A Rc Tank port Rc 70 278 (454) (367) ø80 EXH: Rc 4 x ø (47) (367) ø80 EXH: Rc 4 x ø 442 Tank port Rc 305 80 4 47 T20A : arbon steel onnected to 20A, 40A Tank Rc Rc /4 Spare port Rc ø206 20 80 EXH: 4 x ø3 ø206 20 80 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. onnected to 22A, 42A EXH: 4 x ø3 D 938 400 674 685 Rc /4 00 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. 00 (mm) model A B D Note) 20A 48 394 Rc 40A 520 429.8 Rc 22A 444 394 Rc 469 42A 477 429.8 Rc 493 Note) When option G (pressure gauge) is selected

Air Tank Series T Dimensions: Standard Product (For Japanese Market) T38A : arbon steel onnected to 20A, 40A 355 205 Tank port Rc 3/4 0 824 835 Tank port Rc Tank Rc Rc /4 300 Tank port Rc Tank Rc Rc /4 4 Spare port Rc Rc /4 Tank Rc 63 257 Tank Rc 70 ø256 278 2 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. T05S : Stainless steel 304 onnected to 0A, A T0S : Stainless steel 304 onnected to 0A, A onnected to 20A Rc (370) (307) (39) (8) EXH: 4 x ø3 Rc /4 Rc /4 ø ø80 model 20A 40A 22A 42A onnected to 22A, 42A 00 20 80 ø256 A 53 570 494 527 EXH: Rc /4 4 x ø EXH: Rc /4 4 x ø Rc 2 B 444 479.8 444 479.8 EXH: 4 x ø3 Rc Rc Rc Rc Note) When option G (pressure gauge) is selected onnected to 22A D (mm) D Note) 59 543 ARJ AR425 to 935 ARX AMR ARM ARP IR IRV VEX SRH SRP SRF VHR ITV I ITVX PVQ VEF VEP VER VEA VY T AP00 Tank port Rc 70 278 (454) (367) ø80 EXH: Rc 4 x ø (47) (367) ø80 EXH: Rc 4 x ø 442 Rc /4 20 80 20 80 939

Series T Dimensions: Standard Product (For Japanese Market) T20S : Stainless steel 304 onnected to 20A, 40A onnected to 22A, 42A, 43A Tank port Rc Tank Rc EXH: EXH: 305 80 ø206 4 x ø3 ø206 4 x ø3 D Rc /4 400 674 00 model 20A 40A 22A 42A 43A 00 A 48 520 444 477 526 B 394 429.8 394 429.8 Rc Rc Rc Rc Note) When option G (pressure gauge) is selected (mm) D Note) 469 493 T38S : Stainless steel 304 onnected to 20A, 40A onnected to 22A, 42A, 43A Tank Rc EXH: EXH: Tank port Rc 3/4 D 355 205 ø256 4 x ø3 ø256 4 x ø3 0 824 Rc /4 2 model 20A 40A 22A 42A 43A 2 A 53 570 494 527 576 B 444 479.8 444 479.8 Rc Rc Rc Rc Note) When option G (pressure gauge) is selected (mm) D Note) 59 543 05 R T A- S T A- 0 With safety valve 20 R 38 S With safety valve Rc A Tank model T05 T0 (mm) A 30 2 Rc 940