Porter Analytical & Industrial Products
Porter Analytical & Industrial Products Engineered to Excel in Critical Applications The Porter Instrument Division of Parker Hannifin Corporation is a leading manufacturer of specialized control components for analytical, industrial and medical applications. Since its inception in 1968, Porter's focus has been the development, manufacture and sales of precision instruments for the measurement and control of gases and liquids. The products are a unique family of control devices recognized as the industry standard for critical applications in the chemical/petrochemical, food & beverage quality monitoring, drug analysis, forensics, environmental monitoring and industrial process industries. Contact Information: Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 Phone 215 723 4000 Fax 215 723 2199 industrial@parker.com www.parker.com/porter Contents Pressure Regulators Page 3 Mass Flow Measurement & Control Products Page 4 & 5 Variable Area Flowmeters Page 6 Metering Valves & Manual Flow Controllers Page 7 2
Precision Pressure Regulators Porter Pressure Regulators are designed specifically to provide high resolution control at the low flow rates and pressures typical in analytical instrumentation applications. They are direct acting, non-relieving and specially cleaned for analytical instrument service. For detailed descriptions and specifications on Porter Regulators, request Catalog number FM-1057. Models At a Glance 8310 & 8311 The industry standard for precision low flow gas pressure control. Regulates pressure at flow rates from 1 SCCM up to 3 SLPM. 8286 Balanced poppet for superior supply rejection. Regulates pressure at flow rates from 1 SLPM up to 40 SLPM. 4000 Excellent performance in a compact package designed for smaller instruments. Regulates at flow rates from 500 SCCM up to 10 SLPM. 9000 Low flow back pressure control. Regulates at flow rates from 10 SCCM up to 1 SLPM. Model 8310 Specifications Ratings: Maximum inlet pressure: 250 PSIG Maximum working temperature: 160 F Pressure Drop: Minimum: 10 PSI Maximum: 250 PSI Performance: (Based on 60 PSIG helium supply pressure at 50 PSIG outlet pressure) Supply Rejection: 10 PSI change in supply will not change outlet more than 0.07 PSI Ambient Temperature Effect (temperature coefficent): Music wire- (60 PSIG range) 0.008 PSI/ F Ni-Span-C - (60 PSIG range) 0.004 PSI/ F Drift (Fairprene diaphragm): Less than 0.2% long term Drift (Stainless steel diaphagm): Less than 0.2% Flow Regulation: From 2 SCCM to 250 SCCM helium, outlet pressure will not decrease more than 0.17 PSI for unit with Fairprene diaphragm, 0.3 PSI for unit with stainless steel diaphragm Baseline Oscillation: 0.0012 PSI Precision Adjustment: (resolution): 15 turns 3
Gas Mass Flow Control Products Porter Mass Flow products reflect over four decades of experience in the design and manufacture of precision instruments for the measurement and control of gas flow. They incorporate design principles that are simple and straightforward, yet flexible enough to operate under a wide variety of process parameters. The result is flow meters, flow controllers and control valves that are accurate, reliable and cost-effective solutions for many gas mass flow applications in the analytical, process, chemical/petrochemical, environmental, biopharmaceutical and research markets. For detailed specifications, request catalog number FM-1181. Type Analog Flow Meters Analog Flow Controllers Model Max. Flow 1 (SLPM) Max. Pressure 2 (PSIG) 111 10 1500 121 10 3000 112 100 1500 122 100 3000 113 500 1000 114 1000 1000 2111 10 200 3211 10 1000 201 10 1000 221 10 3000 251 50 1000 202 100 1000 222 100 3000 202A 100 200 203A 500 200 204A 1000 200 2201 10 200 3201/3261 10 1000 Type Model Max. Flow 1 Pressure 2 Max. (PSIA) 510C 9 ml/min 1450 Digital Flow Meters Digital Flow Controllers 511B 25 l/min 1450 511AV 100 l/min 1450 512AC 250 l/min 1450 513AC 1670 l/min 1450 600CV 9 ml/min 928 601CV 25 l/min 928 601AV 100 l/min 928 602AV 250 l/min 928 603AV 1670 l/min 928 1 The maximum full scale flow rate available. 2 The maximum operating inlet pressure available. 3 The minimum required pressure differential for maximum full scale flow rate. NOTE: All flow and pressure specifications are based on N 2 gas. Consult factory for specifications on other gasses. 1 The maximum full scale flow rate available. 2 The maximum operating inlet pressure available. 3 The minimum required pressure differential for maximum full scale flow rate. NOTE: All flow and pressure specifications are based on N 2 gas. Consult factory for specifications on other gasses. 4
Products Series II - Multi Range / Multi Gas MFM and MFC Available from 0.7 SCCM to 1,670 SLPM, Series II combines digital diagnostics with high accuracy and repeatability. Optional Flow Tune software allows the user flexibility in flow range and gas service reducing total inventory cost. Choose from nine I/Os: traditional analog to the new EtherCAT for optimum process control. 100/200 Series Mass Flow Meters and Controllers The latest evolution of the original Porter Analog MFC. With thousands installed worldwide, they are the proven solution when cost effective high performance gas flow control is the goal. The 100 Series Mass Flow Meters are available for applications where flow measurement only is required. Full scale flow rates from 5 SCCM up to 1000 SLPM with 0-5, 0-10 Vdc and 4-20 madc I/O options. 3600 Series Mass Flow Meters & Controllers Digital MFC performance in a robust package designed for severe duty applications. NEMA 4x, IP66, Class 1, Div 2, IECex and Atex Zone 2 Certifications* are available along with a variety of I/O, power requirement and process connection options. Full scale flow rates from 100 SCCM up to 100 SLPM. 3200 Series Mass Flow Meters and Controllers Compact size and Class 1, Div 2 certification makes the 3200 Series the ideal choice for low flow applications in hazardous locations. Available as either a direct mount SP-76 device or with in-line compression fittings. 4-20 madc I/O and 24 Vdc power. Full scale flow rates from 10 SCCM up to 10 SLPM. 2200 Series Mass Flow Meters and Controllers Low cost without compromise in performance. The aluminum and brass constructed 2200 Series features the same sensor, control electronics, flow elements and valve internals as the 200 Series at 30% lower cost. Full scale flow rates from 40 SCCM up to 10 SLPM. MPC Series Mass Flow Controllers A unique concept in cost-efficient mass flow control. These units combine a fast and accurate mass flow controller with the necessary electronics for a complete closed-loop control system and user interface. All in a compact, panel mount, 1/16 DIN package. Full scale flow rates of 0.5, 2.0, 5.0, and 20 SLPM. CM-400 MFC Power Supply/Control Module A high performance microprocessor based 4-channel power supply/control module designed for use with Porter Mass Flow Meters and Controllers. The CM-400 accepts user selectable current or voltage input signals and supplies a selectable setpoint signal for each channel. A programmable multichannel blend control and totalizer with batch function allows the CM-400 to precisely interact with Porter MFCs in a versatile and functional gas management system. 5
Variable Area Flowmeters The Porter Variable Area Flowmeter product line is one of the most extensive offerings available. Acrylic and glass tube purgemeters, high flow glass tube flowmeters and high pressure metal tube armored meters, many with alarm and output options, provide solutions to countless process and analytical flowmeter applications. Purgemeter Product Overview Glass Tube Metal Tube Glass Acrylic High Flow Variable Area Flow Meter Product Summary Overview Flow Rate Capacities Temperature Limits Pressure Limits Type & Style Purgemeter- Glass Model Air Equivalent @ 14.7 F & 70 F Water Equivalent @ 70 F Process Temperature Min-Max Ambient Min-Max Max Inlet Pressure 65mm & F65mm 0.045 SLPM-67.8 SLPM 0.57 CCM -1965 CCM Up to 200 F 33 F to125 F (1 C to 52 C) Up to 200 psi 150mm & F150mm 0.34 SLPM-65.37 SLPM 0.39 CCM -2160CCM Up to 200 F 33 F to 125 F (1 C to 52 C) Up to 200 psi P210 0.0215 SLPM-53.85 SLPM 0.8 GPH -32 GPH Up to 248 F (120 C) 33 F to 125 F (1 C to 52 C) Up to 116 P220 0.0538 SLPM-64.620 SLPM 0.8 GPH - 32 GPH Up to 248 F (120 C) 33 F to 125 F (1 C to 52 C) Up to 116 P230 0.0215 SLPM- 64.620 SLPM 0.8 GPH - 32 GPH Up to 248 F (120 C) 33 F to 125 F (1 C to 52 C) Up to 116 P430 0.066 SLPM- 70 SLPM.011 GPH - 28 GPH Up to 250 F (121 C) 33 F to 125 F (1 C to 52 C) Up to 200 P260 1.077 SLPM- 53.850 SLPM 0.8 GPH - 32 GPH Up to 248 F (120 C) 33 F to 125 F (1 C to 52 C) Up to 116 Purgemeter- Acrylic Purgemeter- High Flow P270 2.15 SLPM- 323 SLPM 16 GPH - 160 GPH Up to 122 F (50 C) Up to 72.5 psi P520 & P530 2.6 SCFM - 60 SCFM 7 GPH - 1200 GPH Up to 130 F (54 C) 33 F to 125 F (1 C to 52 C) Up to 125 psi P240 57 SCFH - 1368 SCFH 16 GPH - 476 GPH Up to 248 F (120 C) Up tp 116 psi P250 N/A for gas applications 16 GPH - 476 GPH Up to 248 F (120 C) Up to 116 psi Glass Tube P480 0.9 SCFM - 350 SCFM 0.22 GPM - 132 GPM Up to 200 F (93 C) 33 F to 125 F (1 C to 52 C) Up to 300 psi P900 1.15 SCFM - 288 SCFM 0.27 GPM- 85 GPM Up to 200 F (93 C) 33 F to 125 F (1 C to 52 C) Up to 300 psi Metal Tube P100 0.4717 SLPM - 56.66 SLPM 0.0027 GPM - 0.4167 GPM Up to 400 F (204 C) 33 F to 125 F (1 C to 52 C) Up to 4500 psi C P710 4 SCFM - 100 SCFM 0.55 GPM - 450 GPM Up to 400 F (204 C) 33 F to 125 F (1 C to 52 C) Up to 1200 psi C P750 2.2 SCFM - 76 SCFM 33 GPH - 990 GPH Up to 400 F (204 C) 33 F to 125 F (1 C to 52 C) Up to 600 psi C P800 452 SCFH - 22820 SCFH 8 GPM - 440 GPM -4 F - 572 F (-20 C - -13 F - 212 F (-25 C - 300 C) 100 C) Up to 595 psi C P810 Lined Check for gas applications 5.2 GPM - 220 GPM -14 F - 248 F (-10 C - 120 C) -13 F - 212 F (-25 C - 100 C) Up to 475 psi C 6
Metering Valves Porter Metering Valves are designed for extremely precise control in low flow gas and liquid applications. They are available as valve cartridges or in-line valve assemblies with straight or angle patterned bodies. All in-line valves assemblies have 1/8'' female NPT inlet and outlet ports. High Resolution Control Valves The HR series High Resolution Control Valves contain unique design features that make them the ultimate choice for precise low flow control. Non-rotating stainless steel valve pin with precision ground flat gives exact control Valve pin o-ring guarentees positive shut-off without stem damage Self-lubricating orifice liner assures long life Seven available needle tapers expand valve capacity Standard Cartridge Valves Porter's Standard Cartridge Valves (SCV) are economical, multi-purpose valve assemblies. Available in 3 needle tapers, they are ideal for a wide spectrum of low flow applications. Capacities Needle Size (HR) 0 1 2 3 4 5 6 Max. cc/min-he 95 220 450 1250 3600 12500 50000 Flow cc/min-h 2 O 2 66 15 30 100 200 900 Needle Size (SCV) 0 1 2 3 4 5 6 Max. cc/min-he 95 220 450 1250 3600 12500 50000 Flow cc/min-h 2 O 2 66 15 30 100 200 900 Maximum Pressure Rating: 250 PSIG 7
WARNING USER RESPONSIBILITY FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Offer of Sale The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributors. This offer and its acceptance are governed by the provisions stated in the detailed Offer of Sale elsewhere in this document or available at www.parker.com/offerofsale. 2011 Parker Hannifin Corporation Bulletin FM-1230 Rev 0 March 2015 Parker Hannifin Corporation Porter Instrument Division 245 Township Line Road Hatfield, PA 19440 phone 215 723 4000 fax 215 723 2199 www.parker.com Your Local Authorized Parker Distributor