ALF400 to 900, ALT-5/-9

Similar documents
ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

LMU100/200 Series. Standard Specifications

Model AWG20 AWG30 AWG40 AWG20K AWG30K AWG40K

How to Order. Rc NPT 1/8 1/4 3/8 1/2

Compressed Air Cleaning Filter Series

Series ACG/ARG/AWG. Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

Modular F.R.L. Units. New. New. Series AC 46% Better visibility and environmental resistance. Energy saving regulator

Direct Operated Precision Regulator Modular Style. Standard Specifications

Modular Air Combination Units

EXH. Specifications. Descriptions. Min. working pressure MPa

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Related Products: Auto Drain Valve. Model/Specifications. Model

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

VACUUM REGULATORS CONTENTS

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

Standard Specifications

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Model Air Caddy Orig TABLE OF CONTENTS

Filter-Regulator-Lubricator

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Filter-Regulator-Lubricator

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

B74G - EXCELON Modular System General purpose filter/regulator

Filter Regulator 21 AW 30 K F 03 BG JN. Description. Without backflow function. Rc NPT 1/8 1/4 3/8 1/2 3/4

Pilot Check Valve: Metal Body Type

Operating Instructions Models and Hydrostatic Test Pumps

Booster Regulator/Air Tank

Operating Instructions Models 36200, , 46200, Hydrostatic Test Pumps

Air Saving Valve. Pressure Valve Flow Valve

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Miniature Tubing & Miniature Fittings

Precision and Instrument Regulators 1/4" port size

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

B84G - Excelon Plus Modular System General purpose filter/regulator

Clean Regulator/Fluororesin Type

Description Pressure range Connection thread Device Page

Series K Air service units G 1/8, G 1/4

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Operating Instructions Model and Hydrostatic Test Pump

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

Air-service devices, Series MU1

Regulator/Modular Style AR1000 to 6000

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

Standard Operating and Maintenance Instructions for Pumping System Model PS-90

Air preparation units

Precision Pressure Regulators

Clean Speed Controller with One-touch Fitting

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

MINIATURE COMBINATION UNITS Filter/regulators and lubricators P1H - G1/8, G1/4

B84G - Excelon Plus Modular System General purpose filter/regulator

Air service units series Y G1/4 to G1

Operating Instructions Models and Hydrostatic Test Pumps

Air service units series K G1/8, G1/4

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

HIGH-PRESSURE RELIEF VALVES

shutoff valves 900 Series psig Manual Shutoff Valves

Operating Instructions Models and Hydrostatic Test Pumps

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Precision Regulator. Series Model Regulating pressure range Port size Page

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

Operating Instructions Models and Hydrostatic Test Pumps

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Operating Instructions Model and Hydrostatic Test Pump

FILTER REGULATOR. We produce with artistic attitude.

Digital Flow Switch. Series PFM7

Miniature Tubing & Miniature Fittings

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

INDUSTRIAL EXCESS ESS FLOW VALVES

Air Operated Hydraulic Pumping Systems to 50,000 psi

OPERATION MANUAL NTF-15

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n

Flow rates to 200 l/min

F.R.L. Units Precautions 1 Be sure to read this before handling.

TRADITIONAL HIGH VIBRATION HOSE SYSTEM THE STANDARD FOR MANY AUTOMOTIVE APPLICATIONS

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

PARTICULATE FILTER/REGULATOR

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

VERTICAL BLADDER TANK

Transcription:

uto Feed Lube, uto Feed Tank LF00 to 900, -/-9 Standard Specifications uto feed lube uto feed tank LF00 LF00-0 LF00 LF00 LF00 LF900 - --IS- -9 IR : OIL : Fluid Proof pressure ir. MPa Max. operating pressure 0. MPa.0 MPa (Note ) Operating pressure differential range (Difference between tank pressure 0. to 0. MPa and line pressure) Vibration resistance (Pressure differential 0. MPa) G (9. m/sec ) or less (Note ) Min. operating flow : : 0 : 00 0 90 0 (L/min (NR)) : 0 : 0 00 owl capacity (cm (Note ) ) (apacity between levels) Recommended lubricant mbient and fluid temperature Turbine oil lass (With no additives), ISO VG ccessory () Part No. Description to 0 (No freezing) racket P -P 000 (00) Part no. LF00 LF00-0 LF00 LF00 LF00 LF900 : -P : -P 000 (00) P Note) float switch can not be mounted on - or -9 afterwards. 9000 (00) -9-IS- 9000 (000) owl material Polycarbonate Metal (Steel tubing for machine construction) Weight (kg) 0. 0....9...0. ccessory (Standard) owl guard Note ) Tank pressure is the pressure of uto Feed Tank and line pressure is the pressure of uto Feed Lube. Note ) onditions: Inlet pressure 0. MPa, drops/min, Turbine oil class (with no additives) ISO VG, Temperature 0, Needle fully open. Use air consumption rate for minimum operating flow. Note ) apacity between levels: in the case of float switch equipped model, the capacity is measured in levels between the level gauge upper limit and the lower limit of the float switch detective range. The problem of running out of oil is prevented because the oil is fed automatically. This system makes lubrication work unnecessary, thus significantly reducing the amount of maintenance labor. L00 L900 LF LD L LMU LIP EP HEP uto feed lube Piping example ir Oil Regulator Filter uto feed lube uto feed tank LF00 - Oil distributor uto feed tank 0

LF00 to 900, -/-9 Series <uto Feed Lube> LF 0 0 0 uto Feed Lube ody size 0 0 0 0 90 <uto Feed Tank> uto Feed Tank Thread Type Rc N NPT E G 0 0 0 0 0 0 Thread type Rc N NPT F G IS- Tank capacity 000 cm tank 9 9000 cm tank How to Order Working Principle/uto Feed Lube R Flow direction: Right to left Description pplicable model With bracket LF00 to 00 Metal case with X0 LF00 to 900 a level gauge R Flow direction: Left to right IS- W/float switch (ottom limit ON) IS- W/float switch (ottom limit OFF) The oil that has been pumped from the tank passes through felt q where it is filtered, and is fed into the case through nozzle w. When the volume of oil reaches a certain level, float e ascends, valve t descends via lever r, nozzle w closes, and the feeding of oil stops, thus completing the oil feeding process. When the oil inside the case is consumed, float e descends, valve t ascends via lever r, allowing oil to be fed from nozzle w. Operating Pressure Range Tank pressure (MPa) Warning aution Operating allowable range Line pressure (MPa) Precautions e sure to read this before handling the products. Refer to back page 0 for Safety Instructions and pages to 9 for Precautions on every series. Mounting If the pressure is discharged, the oil could flow back if the operating pressure differential range (the differential between the tank and line pressures) exceeds 0. MPa. Therefore, make sure to also discharge the tank pressure. Install the float vertically inside the bowl so that it will not come into contact with the siphon tube, preventing the oil from dripping poorly. Maintenance aution Tank and line pressure () () Note ) Tank pressure is removed when line pressure is stopped. Note ) Tank pressure is kept same when line pressure is stopped possible to use. Oil cannot be fed into uto Feed Lube under being pressurized. We recommend oil is supplied from cam handle (plug for oil supply) of an auto feed tank. 0

onstruction: uto Feed Lube LF00 uto Feed Lube LF00 to 900 Series uto Feed Tank -/-9 Series LF00/900 LF00/00 (The figure shows the LF00.) L00 L900 LF LD L LMU LIP EP HEP Replacement Parts No. Description Material uto feed Sight dome -/-9 q Polycarbonate LF00 LF- LF--X0 omponent Parts Material No. Description Note LF00, 00-0 LF00, 00 LF00, 900 ody luminum die-casted luminum casted Platinum silver painted Housing luminum die-casted Platinum silver painted Part no. LF00-0 LF00 LF00 LF00 LF900 LF- LF- LF- LF- LF- LF--X0 LF--X0 LF--X0 LF--X0 LF--X0 umper assembly - (0) () - (0) - 0 0 - (0) () Needle stud assembly Retainer assembly P Note) P Note) P Note) P - P Note) 0 9 0 Siphon tube assembly Sight dome seal Siphon nut seal umper retainer seal owl O-ring Housing O-ring Urethane rubber Urethane rubber NR NR NR 0 0 K00 K00 0 K00 Note ) Description: umper retainer, Material: POM Note ) Description: umper retainer, Material: luminum alloy Note ) ( ): Qty. for LF00 only onstruction: uto Feed Tank t Standard X0 r OUT (OIL) P K00 Qty. () Working principle/uto Feed Tank w y turning cam handle 90 clockwise, valve opens, allowing the air that has entered from the IN side to be introduced into the tank. Due to IN the air pressure, the oil in the tank passes through felt and exits from (IR) the OUT side. Turning cam handle 90 counterclockwise stops the air from the IN side, thus stopping the feeding of the oil. omponent Parts Part no. No. Description Material Qty. (N, E) - (N, E) --IS-, (N, E) -9 (N, E) -9-IS-, e G-0-0(, E) Pressure gauge G-P0-N0-X0(N) am handle assembly P Seal NR Siphon tube assembly Float switch IS0-, IS0-, IS0-: ottom limit ON IS0-: ottom limit OFF Note) 09

LF00 to 900, -/-9 Series Dimensions: uto Feed Lube LF00 LF00/900 D LF00/00 D LF00 LF00-0 LF00 LF00 LF00 LF900 D,,,, 0 90 00 00 00 9 9 0 9 9 Dimensions: uto Feed Tank Float switch ontact point capacity: : V, D: W ontact point construction: a, b Width across flats Lubrication plug Float switch M - --IS -9-9-IS 0 0 0 0 0 0 D E 9 9 F G H 0 0 I J K L 9 M 00

LF00 to 900, -/-9 Related Products: V- Dimensions Oil distributor V Distribution oth sides exhaust One side exhaust V - V - O.D. ø, I.D. ø V- Oil Distributor V, V Series How to Order x ø. hole R / R / Number of distribution ports (V) (V) port port port port 0 0 port port port x ø. pplicable tubing O.D. ø L00 L900 LF LD L LMU LIP EP HEP O.D. ø, I.D. ø R / R / V- V- V0- V- Number of distribution ports 0 T00. 0... 0 0 Note) Insert seal plug (PG) into the distribution port which is not used. ø Specifications Max. operating pressure urst pressure T00. MPa Refer to the burst pressure characteristics curve. Note) Min. bending radius (mm) Operating temperature 0 to 0 Material Nylon Note) The value at temp. of 0 and with O.D. variable rate 0% max. How to Order T 00 0 Nylon tubing Tube size O.D. ø I.D. ø olor W R U Y G Nylon Tubing olor lack White Red lue Yellow Green V- V- V- Length per roll 0 0 m 00 m roll 00 (lack, white only) Number of distribution ports 9... 0 0 90 ø urst Pressure haracteristics urve and Operating Pressure urst pressure (MPa) Max. operating pressure Operating temperature ( ) Maximum operating pressure is / max. of burst pressure at 0, considering the safety ratio. 0

Specialty Lubricators NLF Series uto Feed Lubricators NLF00, 00-0, 00, 00, 00, 900 Specifications uto Feed Lube NLF NLF00 NLF00-N0 NLF00 NLF00 NLF00 NLF900 M ax. supply pressure psig (MPa) 0 (.) M ax. operating pressure psig (MPa) 00 (0.) Pressure differential operating range* psig (MPa) Operating temp. range ~90 (0.~0.) 0 ~0 F R ecommended lubricant Turbine Oil # (ISO VG) owl Lubricator NLF00 Tank N- Polycarbonate M ax. supply pressure psig (MPa) 0 (.) M ax. operating pressure psig (MPa) 0 (.0) O perating temp. range ~0 F (- ~0 ) R ecommended lubricant Turbine Oil # (ISO VG) ody *etween tank and line pressure D uto Feed Lubricator NLF Series NLF00 NLF00-N0 NLF00 NLF00 NLF00 NLF900 Pipe size / / / / / -/ -/ Min. flow for oil drip scfm....... W eight lbs (kgf). (0.).9 (0.). (.0). (.).0 (.).9 (.9) owl guard (standard) racket P -P -P -P *With supply pressure of psig oil drip rate drops/min, use turbine oil # VG, Temperature F P uto Feed Tank N Series uto Feed Tank N N- N--S-* N-9 N-9-S-* N- N--IS-*~ N-9 N-9-IS-*~ P ipe size ir IN: /, OUT: / O il capacity oz (cm) 9 (000) 9 (000) 0 (9000) 0 (9000) W eight lbs (kgf). (.) 9. (.). (.0). (.) F loat switch specification* V oltage 00V 0. 00V 0. *Float switch: oth a low level switch (Float down OFF). and high level float switch is available. dd Suffix for a low level (Float down ON), for high level Return to Menu

NLF Series uto Feed Lubricators NLF00, 00-0, 00, 00, 00, 900 Specialty Lubricators How To Order Pressure haracteristics NLF 00 N0 ody size / / -/ 9 0 / 0 / 0 / 0 / 0 -/ -/ 0 None racket Tank pressure (psig) 0 90 0 0 0 0 0 0 90 00 Line pressure (psig) Dimensions/uto feed lubricator Dimensions/uto feed tank NLF00 Port Size D NLF00-N0 NLF00 NLF00 NLF00 NLF900 Oil Distributor. (0). (). (90).9 (00).9 (00).9 (00) 9.9 (.) 9.0 (.). (9.). (9.). (.). (.) Number of oil outlets. (). ().9 ().0 (). (9). () / / / / -/ Remark / -/ V oth ends V oth ends V0 0 oth ends V oth ends V One side V One side V One side Float Switch Specifications Description IS0-~ apacity : V, D: W Voltage 00V, D0V Proof Pressure psig (MPa) 0 (.) M ax. Oper. Pressure psig (MPa) 0 (.0) Media Water, Oil mbient and Fluid Temperature 0~0 F (~0 ) D E F G H I J K L LT-. (). (0). (). (). (9). (0). (9). 9 ().0 ().0 (). () LT--IS. (). (0). (). (). (9). (0). (9). 9 ().0 ().0 (). (). (9) LT-9 9. (). (0). (0). (). ().9 () 0. (). (0). (). () LT-9-IS 9. (). (0). (0). (). ().9 () 0. (). (0). (). ().9 () Return to Menu