How to Order. Rc NPT 1/8 1/4 3/8 1/2

Similar documents
Modular Type Regulators

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Model AWG20 AWG30 AWG40 AWG20K AWG30K AWG40K

Direct Operated Precision Regulator Modular Style. Standard Specifications

q w e r t Description Rc NPT 1/8 1/4 3/8 1/2

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

ALF400 to 900, ALT-5/-9

Modular F.R.L. Units. New. New. Series AC 46% Better visibility and environmental resistance. Energy saving regulator

Series ACG/ARG/AWG. Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9

Filter Regulator 21 AW 30 K F 03 BG JN. Description. Without backflow function. Rc NPT 1/8 1/4 3/8 1/2 3/4

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

B84G - Excelon Plus Modular System General purpose filter/regulator

B74G - EXCELON Modular System General purpose filter/regulator

Regulator/Modular Style AR1000 to 6000

B84G - Excelon Plus Modular System General purpose filter/regulator

Precision Regulator. Series Model Regulating pressure range Port size Page

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

Modular Air Combination Units

IR1000-A IR1010-A IR1020-A

Series K Air service units G 1/8, G 1/4

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

Digital Flow Switch. Series PFM7

Compressed Air Cleaning Filter Series

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

R84G - Excelon Plus Modular System Pressure regulators

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Air service units series K G1/8, G1/4

Standard Specifications

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Booster Regulator/Air Tank

Air preparation units

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Related Products: Auto Drain Valve. Model/Specifications. Model

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Filter-Regulator-Lubricator

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Filter-Regulator-Lubricator

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator

Pilot Check Valve: Metal Body Type

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

VACUUM REGULATORS CONTENTS

Compact Pressure Switch

INDUSTRIAL PNEUMATICS - air treatment units. FIL filter

F.R.L. Units Precautions 1 Be sure to read this before handling.

lternative odels 3.87 (98) anual Drain 2.67 (68) 3.72 (94) utomatic Drain 2.13 (54) 1.12 (28) P1H, PTH Filter/Regulator-Lubricator Combination Units 0

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

Proportional pressure regulators VPPE

FILTER, REGULATOR AND FILTER/REGULATOR Stainless Steel 316L Compact 1/4, High Flow 1/4-1/2

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Series IRV1000/2000/3000

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Compact Pressure Switch

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Precision Pressure Regulators

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

Thin pressure gauge. G401-W Series. Symbol Descriptions. A Connection A A. B Pressure display [MPa] P04 0 to 0.4MPa P10 0 to 1.

List of Contents VMA. System description 2. Individual Units Pre-Filters 3. Combinations 6. Accessories and Main spare parts 6

Air service units series Y G1/4 to G1

Hand lever valves VHER

Compact Manometer. Pressure measurements can easily be taken any time, anywhere.

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Precision pressure regulators LRP/LRPS

LMU100/200 Series. Standard Specifications

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Compressed Air Cleaning Filter Series

Air-service devices, Series MU1

2-Color Display Digital Flow Switch

Filter pressure regulator, Series AS3-FRE G 3/8 - G 1/2 filter porosity: 5 µm lockable for padlocks with pressure gauge suitable for ATEX

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Multistage Ejector Series ZL

Multistage Ejector Series ZL

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Digital electro-pneumatic regulators Series ER100

Doc. No. AC -OMQ0008-B PRODUCT NAME AIR COMBINATION. MODEL/ Series AC10(A,B)- -A AC20(A,B,C,D)- -A AC25(B,C)- -A AC30(A,B,C,D)- -A AC40(A,B,C,D)- -A

2/ Port G1/4

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

AIR TREATMENT H Z E 0. Air Treatment Units CHARACTERISTICS CODIFICATION KEY. Filter. Ambient temperature Fluid Working pressure Max pressure Size Body

EXH. Specifications. Descriptions. Min. working pressure MPa

MINIATURE COMBINATION UNITS Filter/regulators and lubricators P1H - G1/8, G1/4

The plastic bowl guard does not corrode. The draining method is selectable between the push type and the auto drain type.

Operation Manual Air Saver Unit ASV5000 Series

Clean Speed Controller with One-touch Fitting

DPS-400 SERIES DPH-100 SERIES

PARTICULATE FILTER/REGULATOR

Transcription:

AWM 3 AWD 3 Mist Separator Regulator AWM2 to AWM4 Micro Mist Separator Regulator AWD2 to AWD4 3 E 3 E How to Order Mist Separator Regulator 1 2 Micro Mist Separator Regulator The AWM series is made up of a regulator and a mist separator to provide optimum results in applications such as clean air blow operations. (ominal filtration rating:.3 µm) The AWD series is made up of a regulator and a micro mist separator to provide optimum results in applications such as ultraclean air blow operations. (ominal filtration rating:.1 µm) Made to Order For details, refer to pages 594 and 595. L 1 2 Option/Semi-standard: Select one each for a to i. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AWM3-3E-1 L 2 ody size 3 4 ote 3) Semi-standard Option 586 Thread type a b c d e f Port size Mounting Float type auto drain Pressure gauge Digital pressure switch pressure owl Drain port ote 8) ote 6) ote 9) F ote 1) ote 2) 1 2 3 4 H ote 4) D E M E1 E2 E3 E4 ote 5) ote 5) ote 5) ote 5) 1 ote 7) 2 6 8 6 W ote 1) ote 11) Without mounting option With bracket With set nut Without auto drain Float type auto drain (..) Float type auto drain (.O.) Rc PT 1/4 3/8 1/2 Without pressure gauge Square embedded type pressure gauge Round type pressure gauge Round type pressure gauge (with color zone) Output: P output / Electrical entry: Wiring bottom entry Output: P output / Electrical entry: Wiring top entry Output: PP output / Electrical entry: Wiring bottom entry Output: PP output / Electrical entry: Wiring top entry.5 to.85 MPa setting.5 to.2 MPa setting Polycarbonate bowl Metal bowl ylon bowl Metal bowl with level gauge With bowl guard ylon bowl with bowl guard With drain cock Drain guide Drain guide 1/4 Drain cock with barb fitting: For ø6 x ø4 nylon tube

Mist Separator Regulator AWM2 to AWM4 Series Micro Mist Separator Regulator AWD2 to AWD4 Series Semi-standard g h Standard Specifications Port size Fluid Proof pressure Maximum operating pressure pressure range ote 1) Pressure gauge port size Ambient and fluid temperature ominal filtration rating Outlet side oil mist concentration Rated flow (L/min (AR)) Drain capacity (cm 3 ) owl material owl guard onstruction Weight (kg) Exhaust mechanism Flow direction R ote 5) ote 2) Relieving type on-relieving type Flow direction: Left to right Flow direction: Right to left AWM2 to AWM4 AWD2 to AWD4 AWM2 to AWM4 AWD2 to AWD4 AWM2 to AWM4 AWD2 to AWD4 i Pressure unit ote 12) Z ame plate, caution plate for bowl, and pressure gauge in imperial units: MPa ame plate, caution plate for bowl, and pressure gauge in imperial units: psi, F ote 13) ZA Digital pressure switch: With unit conversion function ote 1) Drain guide is PT (applicable to the AWM2, AWD2) and PT1/4 (applicable to the AWM3 to AWM4, AWD3 to AWD4). The auto drain port comes with ø3/8" one-touch fitting (applicable to the AWM3 to AWM4, AWD3 to AWD4). ote 2) Drain guide is (applicable to the AWM2, AWD2) and 1/4 (applicable to the AWM3 to AWM4, AWD3 to AWD4). ote 3) Option,, H, M are not assembled and supplied loose at the time of shipment. ote 4) Assembly of a bracket and set nuts ote 5) When choosing with H (panel mount), the installation space for lead wires will not be secured. In this case, select wiring bottom entry for the electrical entry. ote 1) Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge. ote 2) 5 to 5 for the products with the digital pressure switch. ote 3) When the compressor oil mist discharge concentration is 3 mg/m 3 (AR). ote 6) Float type auto drain: when used in combination with or D, minimum set pressure is:.o. type.1 MPa;.. type.1 MPa (AD27) and.15 MPa (AD37/47). ote 7) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of.2 MPa or more. When the pressure gauge is attached, a.2 MPa pressure gauge will be fitted. ote 8) Refer to hemical Data on page 387 when selecting a case material. ote 9) Float type auto drain: The combination of and D is not possible. ote 1) Without a valve function ote 11) Metal bowl: The combination of 2 and 8 is not possible. AWM2 AWD2 AWM2, AWD2 AWM3 AWD3 ody size 3 4 AWM4 AWD4, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Air 1.5 MPa 1. MPa.5 to.85 MPa 1/4 5 to 6 (with no freezing).3 µm (99.9% filtered particle size).1 µm (99.9% filtered particle size) Max. 1. mg/m 3 ote 3) ote 4) (AR) (.8 ppm) Max..1 mg/m 3 (AR) (efore saturated with oil.1 mg/m 3 (AR) or less.8 ppm) 15 9 8 33 18 25 82 45 45 Polycarbonate Semi-standard Standard Relieving type.29.59 1.25 2 AWM4, AWD4 ote 12) For thread type: PT. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in apan.) The digital pressure switch will be equipped with the unit conversion function, setting to psi initially. The combination of the round type pressure gauge with color zone M and a psi display Z is not orderable as a standard product. However, this combination is available as a special. ote 13) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in apan.) : For thread type: PT only : Select with options: E1, E2, E3, E4. ote 3) ote 4) ote 4) owl O-ring and other O-rings are slightly lubricated. ote 5) onditions: Mist separator inlet pressure:.7 MPa; outlet pressure:.5 MPa. The rated flow varies depending on the inlet pressure. Keep the air flow within the rated flow to prevent an outflow of lubricant to the outlet side. 587 A-A AR-A AW-A A- AR -A - AW -A - AW A E AV AF

AWM2 to AWM4 Series AWD2 to AWD4 Series Options/Part o. racket assembly nut Pressure gauge Optional specifications ote 1) Digital pressure switch Float type auto drain Standard ote 2) Round type ote 2) Round type (with color zone) Square embedded ote 3) type ote 4) ote 5) ote 6).2 to.2 MPa setting Standard.2 to.2 MPa setting Standard.2 to.2 MPa setting P output / Wiring bottom entry P output / Wiring top entry PP output / Wiring bottom entry PP output / Wiring top entry...o. AWM2 AWM3 AWD2 AWD3 AW2P-27AS AR3P-27AS AR2P-26S AR3P-26S 36-1-1 36-2-1 36-1-1-L 36-2-1-L 3-1AS [3P-1AS (Pressure gauge cover only)] 3-2AS [3P-1AS (Pressure gauge cover only)] ISE35--25-MLA [ISE35--25-M (Switch body only)] ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] ISE35--65-MLA [ISE35--65-M (Switch body only)] ISE35-R-65-MLA [ISE35-R-65-M (Switch body only)] AD27 AD37 AD38 AWM4 AWD4 AR4P-27AS AR4P-26S 46-1-2 46-2-2 46-1-2-L 46-2-2-L AD47 AD48 Semi-standard/owl Assembly Part o. Semi-standard specifications owl material Polycarbonate ylon Metal Metal bowl with level gauge ote 5) ote 6) Float type auto drain...o. ote 6) With drain guide With barb fitting With bowl guard AWM2 AWD2 2SF- AD27-2SF- 2SF- 2SF-6 2SF-6 AD27-6 AD27-6 2SF-6 2SF-6 2SF-2 AD27-2 2SF-2 ote 1) Assembly of a bracket and set nuts ote 2) in part numbers for a round pressure gauge indicates a type of connection thread. o indication is necessary for R; however, indicate for PT. Please contact SM regarding the connection thread PT and pressure gauge supply for psi unit specifications. ote 3) Including one O-ring and 2 mounting screws. [ ]: Pressure gauge cover only ote 4) Lead wire with connector (2 m), adapter, lock pin, O-ring (1 pc.), mounting screw (2 pcs.) are attached. [ ]: Switch body only. Also, regarding how to order the digital pressure switch, please refer to page 596. ote 5) Minimum operating pressure:.o. type.1 MPa;.. type.1 MPa (AD27) and.15 MPa (AD37/47). Please contact SM for psi and F unit specifications. ote 6) Please consult SM for details on drain piping to fit PT or port sizes. ote) Including O-ring. owl assembly for the AWM3/4, AWD3/4 comes with a bowl guard (steel band material). (except when the bowl material is metal) AWM3 AWD3 3SF- 3SF-W 3SF-6 AD37-6 AD38-6 3SF-6 3SF-6W 3SF-2 AD37-2 AD38-2 3SF-2 3LF-8 AD37-8 AD38-8 3LF-8 AWM4 AWD4 4SF- 4SF-W 4SF-6 AD47-6 AD48-6 4SF-6 4SF-6W 4SF-2 AD47-2 AD48-2 4SF-2 4LF-8 AD47-8 AD48-8 4LF-8 588

AWM2 to AWM4 Series AWD2 to AWD4 Series Specific Product Precautions e sure to read this before handling the products. Refer to back page 5 for Safety Instructions and pages 387 to 391 for F.R.L. Precautions. Warning Selection 1. Residual pressure release (outlet pressure release) is not complete by releasing inlet pressure. Please contact SM regarding residual pressure release. aution Warning Air Supply 1. Install an air filter (AF series) as a pre-filter on the inlet side of the mist separator regulator to prevent premature clogging. 2. Install a mist separator (AFM series) as a pre-filter on the inlet side of the micro mist separator regulator to prevent premature clogging. Maintenance 1. Replace the element every 2 years or when the pressure drop becomes.1 MPa, whichever comes first, to prevent damage to the element. aution Mounting and Adjustment 1. the regulator while verifying the displayed values of the inlet and outlet pressure gauges. Turning the regulator knob excessively can cause damage to the internal parts. 2. The pressure gauge included with regulators for.2 to.2 MPa setting is for up to.2 MPa use only. Exceeding.2 MPa of pressure can damage the gauge. 3. Do not use tools on the pressure regulator knob as this may cause damage. It must be operated manually. Warning Mounting and Adjustment 1. e sure to unlock the knob before adjusting the pressure and lock it after setting the pressure. Failure to follow this procedure can cause damage to the knob and the outlet pressure may fluctuate. Pull the pressure regulator knob to unlock. (You can visually verify this with the "orange mark" that appears in the gap.) Push the pressure regulator knob to lock. When the knob is not easily locked, turn it left and right a little and then push it (when the knob is locked, the "orange mark", i.e., the gap will disappear). Orange mark 2. A knob cover is available to prevent careless operation of the knob. Refer to page 597 for details. A-A AR-A AW-A A- AR -A - AW -A - AW A E AV AF 589

AWM2 to AWM4 Series AWD2 to AWD4 Series Flow Rate haracteristics (Representative values) ondition: Inlet pressure.7 MPa AWM2 Rc 1/4 AWM3 Rc 3/8 AWM4 Rc 1/2.6.6.6.5.4.3.2.5.4.3.2.5.4.3.2.1.1.1 5 1 Flow rate (L/min (AR)) 1 2 15 3 Flow rate (L/min (AR)) 5 1 Flow rate (L/min (AR)) AWD2 Rc 1/4 AWD3 Rc 3/8 AWD4 Rc 1/2.6.6.6.5.4.3.2.5.4.3.2.5.4.3.2.1.1.1 5 1 Flow rate (L/min (AR)) 1 2 Flow rate (L/min (AR)) 1 2 3 4 5 Flow rate (L/min (AR)) Pressure haracteristics (Representative values) AWM2 AWM3 onditions: Inlet pressure.7 MPa, Outlet pressure.2 MPa, Flow rate 2 L/min (AR) AWM4.25.25.25.2.15.2.15.2.15.2.3.4.5.6.7.8.9 1.2.3.4.5.6.7.8.9 1.2.3.4.5.6.7.8.9 1 AWD2 AWD3 AWD4.25.2.15.25.2.15.25.2.15.2.3.4.5.6.7.8.9 1.2.3.4.5.6.7.8.9 1.2.3.4.5.6.7.8.9 1 59

Mist Separator Regulator AWM2 to AWM4 Series Micro Mist Separator Regulator AWD2 to AWD4 Series onstruction AWM2 AWD2 AWM3, AWM4 AWD3, AWD4 I w t q e y r u I w t q y e r u A-A AR-A AW-A A- Drain Drain AR -A - AW -A - omponent Parts o. 1 2 Replacement Parts o. 3 4 5 6 7 ody onnet Valve assembly Element assembly Diaphragm assembly owl O-ring owl assembly ote 1) Material Aluminum die-cast Polyacetal Material rass, HR AWM2 to AWM4 AWD2 to AWD4 Weatherable R R Polycarbonate AWM2 to AWM4 AWD2 to AWD4 AWM2 to AWM4 AWD2 to AWD4 AWM2 AWD2 AWM2P-9AS AFM2P-6AS AFD2P-6AS AR2P-15AS 2SFP-26S 2SF ote 1) owl O-ring is included. Please contact SM regarding the bowl assembly supply for psi and F unit specifications. ote 2) owl assembly for the AWM3/4, AWD3/4 comes with a bowl guard (steel band material). olor Platinum silver lack Part no. AWM3 AWD3 AWM3P-9AS AFM3P-6AS AFD3P-6AS AR3P-15AS 3SFP-26S 3SF ote 2) AWM4 AWD4 AWM4P-9AS AFM4P-6AS AFD4P-6AS AR4P-15AS 4SFP-26S 4SF ote 2) AW A E AV AF 591

O S O S RS O S O AWM2 to AWM4 Series AWD2 to AWD4 Series Dimensions AWM2 AWD2 F T M D U racket (Option) Panel fitting dimension Y I W I K V Q Z Plate thickness AWM2, AWD2: Max. 3.5 P2 (Pressure gauge port size) 2 x P1 (Port size) AWM3, AWM4 AWD3, AWD4 F Drain A T S learance for maintenance R M D U racket (Option) Panel fitting dimension Y I W Q Z I K V Plate thickness AWM3, AWD3: Max. 3.5 AWM4, AWD4: Max. 5 P2 (Pressure gauge port size) 2 x P1 (Port size) Drain A learance for maintenance E Applicable model AWM2 to AWM4, AWD2 to AWD4 Option Square embedded type pressure gauge Digital pressure switch Round type pressure gauge Round type pressure gauge (with color zone) Dimensions H enter of piping H enter of piping H enter of piping Applicable model AWM2, AWD2 AWM3/4, AWD3/4 Optional/Semi-standard With auto drain (..) Metal bowl With drain guide With auto drain (.O./..) Metal bowl Metal bowl with level gauge With drain guide Drain cock with barb fitting specifications Dimensions M5 x.8.o.: lack..: ray ø1 one-touch Width across flats 14 fitting S 1/4 Width across flats 17 arb fitting Applicable tubing: T64 AWM2/AWD2 AWM3/AWD3 AWM4/AWD4 Standard specifications P1 P2 A ote) D E F, 1/4 1/4, 3/8 1/4, 3/8, 1/2 1/4 4 53 7 173 21 239 73 86 92 26 29.5 37.5 3 38 M28 x 1 M38 x 1.5 M42 x 1.5 4 55 8 26 29.5 37.5 K 5 3.5 1.5 Square type pressure gauge H 28 27 28 3.5 28 38.5 Optional specifications Digital pressure switch H 27.8 37.5 27.8 41 27.8 49 Round type pressure gauge H ø37.5 62.5 ø37.5 66 ø42.5 76 Round type pressure gauge (with color zone) H ø37.5 63 ø37.5 66 ø42.5 76 Optional specifications Semi-standard specifications Metal bowl with racket mount Panel mount With auto drain With barb fitting With drain guide Metal bowl level gauge AWM2/AWD2 AWM3/AWD3 AWM4/AWD4 M 3 41 5 34 4 54 Q 44 46 54 R 5.4 6.5 8.5 S 15.4 8 1.5 T 55 53 7 U 2.3 2.3 2.3 V 3 31 35.5 W 28.5 38.5 42.5 Y 14 19 21 Z 6 7 7 ote) 19 242 278 ote) 29 247 ote) 177 28 246 ote) 173 214 252 ote) 234 272 ote) The total length of dimension is the length when the filter regulator knob is unlocked. 592

Mist Separator Regulator AWM2 to AWM4 Micro Mist Separator Regulator AWD2 to AWD4 Made to Order Specifications: Please contact SM for detailed dimensions, specifications and lead times. q.4 MPa ting The maximum set pressure is.4 MPa. When a pressure gauge is included, the display will show a range from to.4 MPa. w Long owl Drain capacity is greater than that of standard models. Specifications Proof pressure Maximum operating pressure pressure range Applicable Port size 1.5 MPa 1. MPa.5 to.4 MPa AWM2 AWM3 AWM4 AWD2 AWD3 AWD4, 1/4 1/4, 3/8 1/4, 3/8, 1/2 Applicable /Drain apacity Port size Drain capacity (cm 3 ) AWM2 AWD2, 1/4 19 ote) Please consult SM for dimensions. AWM3 AWD3 1/4, 3/8 43 AWM4 AWD4 1/4, 3/8, 1/2 88 How to Order AWM 3 3 X46 AWD 3 3 X46 X46 X64.4 MPa setting Long bowl Option/Semi-standard: Select one each for a to i. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. Example) AWM3-3E-2-X46.4 MPa ting Long owl ote 3) Option Thread type a b c Port size Mounting Float type auto drain Pressure gauge Digital pressure switch ote 1) F ote 2) 1 2 3 4 Without mounting option ote 4) With bracket H With set nut (for panel fitting) D E M E1 ote 5) E2 ote 5) E3 ote 5) E4 ote 5) Without auto drain Float type auto drain (..) Float type auto drain (.O.) Rc PT 1/4 3/8 1/2 Without pressure gauge Square embedded type pressure gauge (with limit indicator) Round type pressure gauge Round type pressure gauge (with color zone) Output: P output / Electrical entry: Wiring bottom entry Output: P output / Electrical entry: Wiring top entry Output: PP output / Electrical entry: Wiring bottom entry Output: PP output / Electrical entry: Wiring top entry ody size 2 3 4 ody size 2 3 4 ote 1) Drain guide is PT (applicable to the AWM2, AWD2) and PT 1/4 (applicable to the AWM3 to AWM4, AWD3 to AWD4). The auto drain port comes with ø3/8" Onetouch fitting (applicable to the AWM3 to AWM4, AWD3 to AWD4). ote 2) Drain guide is (applicable to the AWM2, AWD2) and 1/4 (applicable to the AWM3 to AWM4, AWD3 to AWD4). ote 3) Option,, H, M are not assembled and supplied loose at the time of shipment. ote 4) Assembly of a bracket and set nuts ote 5) When choosing with H (panel mount), the installation space for lead wires will not be secured. In this case, select wiring bottom entry for the electrical entry. 594

Mist Separator Regulator AWM2 to AWM4 Series Micro Mist Separator Regulator AWD2 to AWD4 Series A-A AR-A AW-A A- AR -A - Semi-standard e owl ote 8) g Exhaust mechanism h Flow direction d ote 6) pressure 1 ote 7) 2 6 8 6 R Polycarbonate bowl Metal bowl ylon bowl Metal bowl with level gauge With bowl guard ylon bowl with bowl guard Relieving type on-relieving type Flow direction: Left to right Flow direction: Right to left With drain cock f ote 9) Drain port ote 1) W ote 11) Drain guide Drain guide 1/4 Drain cock with barb fitting: For ø6 x ø4 nylon tube.5 to.85 MPa setting.5 to.2 MPa setting ame plate and caution plate for bowl in imperial units: MPa i Pressure unit Z ote 12) ame plate and caution plate for bowl, and pressure gauge in imperial units: psi, F ZA ote 13) Digital pressure switch: With unit conversion function ote 6) Float type auto drain: when used in combination with or D, minimum set pressure is:.o. type.1 MPa;.. type.1 MPa (AD27) and.15 MPa (AD37/47). ote 7) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of.2 MPa or more. When the pressure gauge is attached, a.2 MPa pressure gauge will be fitted. ote 8) Refer to hemical Data on page 387 when selecting a case material. ote 9) Float type auto drain: The combination of and D is not possible. ote 1) Without a valve function ote 11) Metal bowl: The combination of 2 and 8 is not possible. ote 12) For thread type: PT. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in apan.) The digital pressure switch will be equipped with the unit conversion function, setting to psi initially..4 MPa ting Long owl ody size 2 3 4 ody size 2 3 4 ote 13) For options: E1, E2, E3, E4. This product is for overseas use only according to the new Measurement Law. (The SI unit is provided for use in apan.) : For thread type: PT only : Select with options: E1, E2, E3, E4. AW -A - AW A E AV AF 595

Option Digital Pressure Switch ISE35 25 M L A q w e r t Electrical entry Output Display unit ote 1) Lead wire Accessories R 25 65 Wiring bottom entry Wiring top entry P output PP output ote 2) With unit conversion function M Fixed SI unit P ote 2) Pressure unit: psi (initial value) with unit conversion function L A Without lead wire Lead wire (2 m) with connector Without accessories (switch body only) With accessories (adapter, O-ring (1 pc.), mounting screw (2 pcs.), lock pin) ote 1) Under the ew Measurement Law, sales of switches with the unit switching function are not allowed for use in apan. ote 2) ame plate is included. ote 3) Operation Instruction manual is attached. ote 4) When ordering the body only, select the symbol from q to e respectively. Option/Part no. When optional parts are required separately, use the following part numbers to place an order. Part no. Option ZS-32-A Lead wire (2 m) with connector ZS-32- Accessories (adapter, O-ring (1 pc.), mounting screw (2 pcs.), lock pin) Specifications Rated pressure range Display/ pressure range Withstand pressure Display/ pressure resolution Fluid Power supply voltage urrent consumption Switch output Max. load current Max. applied voltage Residual voltage Response time Short circuit protection Repeatability to 1 MPa.1 to 1 MPa 1.5 MPa.1 MPa Air, Inert gas, on-flammable gas 12 to 24 VD, Ripple (p-p) 1% or less (with power supply polarity protection) 55 ma or less (at no load) P or PP open collector 1 output 8 ma 3 V (with P output) 1 V or less (with load current of 8 ma) 1 s (Response time selections:.25,.5, 2, 3) With short circuit protection ±1%F.S. Applicable Series F.R.L. unit A2, A25, A3, A4, A5, A55, A6 A2A, A3A, A4A, A5A, A6A A2, A25, A3, A4, A5, A55, A6 A2, A25, A3, A4 A2D, A3D, A4D AR2(K), AR25(K), AR3(K), AR4(K), Regulator AR5(K), AR6(K) Filter regulator AW2(K), AW3(K), AW4(K), AW6(K) Mist separator regulator AWM2, AWM3, AWM4 Micro mist separator regulator AWD2, AWD3, AWD4 Diigtal Pressure Switch Details Example) Regulator Hysteresis Display Hysteresis mode Window comparator mode Variable (can be set from ) 3-digit, 7-segment indicator, 2-color display (Red/reen) can be interlocked with the switch output. Display accuracy Indicator light ±2%F.S. ±1 digit (at 25 ± 3 ) Illuminates when output is turned O. (reen) Environmental resistance Enclosure Operating temperature range IP4 5 to 5 (with no freezing and condensation) Lead wire with connector ote) (Option: L) Weihgt Standard ø3.4 3-wire 25AW 2 m With connector cover Approx.14 g (body only), Approx.38 g (including lead wire with connector) E, UL, SA, RoHS ote) For details about the wiring, refer to the Operation Manual at SM website (http://www.smcworld.com). 596 For details about the Pressure Switch Precautions, refer to est Pneumatics o. 8. For details about the Specific Product Precautions, refer to the Operation Manual at SM website. q w e r t Dimensions: Lead wire with connector ZS-32-A rown D () lack (1) lue D ( ) O Adapter Lock pin O-ring Digital pressure switch (ody only ) Lead wire with connector M3 x.5 x 7 (Screw for aluminum materials) 22 O-ring Digital pressure switch (ody only ) Wiring top entry Wiring bottom entry

Option Knob over Prevents careless knob operation. Lock cover Keyhole dia.: ø8 Lock (supplied by customers) Part no. Applicable model AR2P-58AS A2, AR2(K), AW2(K), AWM2, AWD2 AR25P-58AS A25, AR25(K) AR3P-58AS AR4P-58AS A3, AR3(K), AW3(K), AWM3, AWD3 A4(-6), AR4(K)(-6), AW4(K)(-6), AWM4, AWD4 A-A AR-A AW-A A- AR -A - AW -A - AW A E AV AF 597