Series AWD20/30/40. Micro Mist Separator Regulator. How to Order

Similar documents
Related Products: Auto Drain Valve. Model/Specifications. Model

How to Order. Rc NPT 1/8 1/4 3/8 1/2

How to Order. Accessory. Symbol. Nil. Port size. Accessory/Optional Specifications Combinations. Accessory. Combination D C -J -R -W -Z AF20

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Series IRV1000/2000/3000

Standard Specifications. Model IN side OUT side. Proof pressure Maximum operating pressure. Regulating pressure range

Series AMJ. Drain Separator for Vacuum

Series IR1000/2000/3000

Direct Operated Precision Regulator Modular Style. Standard Specifications

Modular Type Regulators

Specifications Fluid Max. operating pressure Min. operating pressure Proof pressure Ambient and fluid temperature Filtration degree Element life

Safety Speed Control Valve (SSC Valve) Model. Style ASS100 ASS Meter-out control ASS500 ASS600 ASS110 ASS310. Meter-in control.

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Port size. Model AQ1500-M5 AQ AQ AQ AQ AQ AQ AQ Specifications. Fluid Proof pressure AQ1500

Model AWG20 AWG30 AWG40 AWG20K AWG30K AWG40K

Regulator/Modular Style AR1000 to 6000

Micro Mist Separator with Prefilter. Model Model Note) Rated flow (l/min (ANR)) Port size (Nominal size B) AMH

Model Model Note) Rated flow (l /min (ANR)) AMG

Direct Operated Precision Regulator Modular Style. Standard Specifications

Filter-Regulator-Lubricator

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Pilot Check Valve: Metal Body Type

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Filter-Regulator-Lubricator

ALF400 to 900, ALT-5/-9

ALF400 to 900, ALT-5/-9

Vacuum / Release Unit

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

Series VBA1110 to 4200

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Series ZFC. Air Suction Filter. In-line Type with One-touch Fittings

Air operated valve. VGA342R Series

q w e r t Description Rc NPT 1/8 1/4 3/8 1/2

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

ALF400 to 900, ALT-5/-9

F.R.L. Units Precautions 1 Be sure to read this before handling.

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Modular F.R.L. Units. New. New. Series AC 46% Better visibility and environmental resistance. Energy saving regulator

IR1000-A IR1010-A IR1020-A

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Operation Manual Air Saver Unit ASV5000 Series

THE WORLD COMPETITIVENESS SCOREBOARD 2011

Series ACG/ARG/AWG. Regulator with Built-in Pressure Gauge Filter Regulator with Built-in Pressure Gauge

HydroCOM: High energy savings and excellent controllability

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Modular Air Combination Units

Industrial Filter. FGD series

F.R.L. Units Precautions 1 Be sure to read this before handling products.

CAT.ES60-17 A. Compact Electro-pneumatic Regulator. Series ITV0000. Compact and lightweight electro-pneumatic regulator

Booster Regulator/Air Tank

Max Sort Sortation Option - Letters

Clean Air Filter Built-in Hollow Fiber Element

Low torque Metal seal type Rotary joint

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Miniature Tubing & Miniature Fittings

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

Precision Regulator. Series Model Regulating pressure range Port size Page

Masoneilan* 78 Model Air Filter Regulator

Compressed Air Cleaning Filter Series

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

NITROGEN CHARGING KIT type PC 11.1 E 04-11

NITROGEN CHARGING KIT type PC 11.1 E 01-12

B84G - Excelon Plus Modular System General purpose filter/regulator

PVC Quick Drain Valve

5 Port Air Operated Valve

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

B74G - EXCELON Modular System General purpose filter/regulator

VACUUM REGULATORS CONTENTS

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

GE Oil & Gas Model. Masoneilan* Air Lock-up Valve Instruction Manual. GE Data Classification : Public

Clean Regulator/Fluororesin Type

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

B84G - Excelon Plus Modular System General purpose filter/regulator

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces

Compressed Air Cleaning Filter Series

Transcription:

Micro Mist Separator Regulator Series /30/40 Series AWD is a component made up of a regulator and a micro-mist separator that are integrated to provide optimum results in applications such as ultraclean air blow operations. JIS Symbol Filtration: 0.01 µm AWD 30 F 03 E 1N Micro mist separator regulator Accessory/Optional Specification ombinations Accessory Optional specifications Thread type Nil Rc N (1) NPT F (2) Accessory/Optional specifications With bracket (With set nut) Float type auto-drain (N..) Float type auto-drain (N.O.) Square embedded type pressure gauge Round pressure gauge Panel mount (With set nut) 0.05 to 0.2 MPa setting Metal bowl Nylon bowl Metal bowl with level gauge With bowl guard Drain guide 1/4 Non-relieving type Flow direction: Right Left Drain cock with barb fitting: ø6 x ø4 nylon tubing Name plate, caution plate for bowl, and pressure gauge in imperial units (PSI, F) 14-2-82 ody size 20 30 40 Note 1) Drain guide is for NPT 1/4 (applicable to AWD30 and ), and the exhaust port for auto-drain comes with ø3/8" One-touch fitting (applicable to AWD30 and ). Note 2) Drain guide is 1/4 (applicable to AWD30 and ). Port size Symbol 01 02 03 04 Port size 1/8 1/4 3/8 2/1 ody size 20 30 40 ombination Symbol D E H -1-2 -6-8 - -J -N -R -W -Z Accessory Option Symbol 1 (4) 2 6 8 J (5) N R W Z (6) Accessory (3) Symbol Nil D E H How to Order Description 0.05 to 0.2 MPa setting Metal bowl Nylon bowl Metal bowl with level gauge With bowl guard Drain guide 1/4 Non-relieving Flow direction: Right Left Drain cock with barb fitting: ø6 x ø4 nylon tubing Name plate, caution plate for bowl, and pressure gauge in imperial units (PSI, F) Description With bracket Float type auto-drain (N..) (4) Float type auto-drain (N.O.) (4) With square embedded type pressure gauge (With limit indicator) With round pressure gauge (With limit indicator) With set nut (For panel mount) Optional specifications Applicable model When more than one specification is required, indicate in alphanumeric order. Note 4) The only difference from the standard specifications is the adjusting spring for the regulator. It does not restrict the setting of 0.2 MPa or more. Note 5) Without a valve function. Note 6) For NPT thread type. This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) : ombination available : Varies depending on the model Applicable model Note 3) Optional parts are not assembled and are supplied loose at the time of shipment (except options, D and E). Note 4) Applicable tubing O.D for auto-drain connection should be ø3/8" in case NPT thread port is chosen. : ombination not available : Available only with NPT thread Applicable micro mist separator regulator D E H 1 2 6 8 J N R W Z AWD30 to 40

Micro Mist Separator Regulator Series /30/40 Standard Specifications Model Port size Fluid Proof pressure Maximum operating pressure Set pressure range Pressure gauge port size (1) Ambient and fluid temperature Nominal filtration rating Outlet side oil mist concentration Rated flow (l/min (ANR)) (4) owl material owl guard Drain capacity (cm 3 ) onstruction Weight (kg) Accessory part no. Applicable model Accessory racket assembly (1) Set nut Round (2) 1.0 MPa (3) Pressure Square embedded type gauge Round 0.2 MPa (3) 1/8, 1/4 AWD30 1/4, 3/8 Air 1/4, 3/8, 1/2 1.5 MPa 1.0 MPa 0.05 to 0.85 MPa Rc, NPT, 1/8 Rc, NPT, 1/8 Rc, NPT, 1/4 5 to 60 (With no freezing) 0.01µm (95% filtered particle size) Max. 0.1 mg/m 3 (ANR) (2) (3) (efore saturated with hydraulic fluid: 0.01 mg/m 3 (ANR) or less, approx. 0.008 ppm ) 90 Option 8 0.44 AW20P-270AS AR20P-260S 36-10-01 3-10AS 36-2-01 3-2AS AD27 180 Polycarbonate Standard 25 Relieving type 0.59 AWD30 AR30P-270AS AR30P-260S 36-10-01 3-10AS 36-2-01 3-2AS AD38 AD38N Note) AD37 AD37N Note) 450 45 1.25 AR40P-270AS AR40P-260S 46-10-02 3-10AS 46-2-02 3-2AS AD48 AD48N Note) AD47 AD47N Note) Square embedded type Float type (4) N.O. auto-drain N.. Note) When N is specified in the end of part number of auto drain, applicable tubing O.D should be ø3/8". Precautions Note 1) Pressure gauge connection threads are not required for the regulator with a square embedded type pressure gauge (). Note 2) When the compressor oil mist discharge concentration is 30 mg/m 3 (ANR). Note 3) owl O-ring and other O-rings are slightly lubricated. Note 4) When the outlet pressure is 0.5 MPa. (The rated flow varies depending on the set pressure.) Keep the air flow within the rated flow to prevent an outflow of lubricant to the outlet side. Note 1) Assembly includes a bracket and set nuts. Note 2) in part numbers for a round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N for NPT. Please contact SM regarding the NPT connection thread and pressure gauge supply for PSI unit specifications. Note 3) Includes one O-ring and 2 mounting screws. Note 4) Minimum operating pressure: N.O. type 0.1 MPa; N.. type 0.1 MPa (AD27) and 0.15 MPa (AD37/47). Set the pressure to allow a pressure drop when the fluid flows. Please contact SM regarding the specifications for PSI unit and F. e sure to read before handling. Refer to pages 14-21-3 to 14-21-4 for Safety Instructions and ommon Precautions. F.R.L. AV AU AF AR IR VEX AMR ITV I VA VE VY1 PPA AL Selection 1. Residual pressure release (outlet pressure release) is not complete by releasing inlet pressure. Please contact SM regarding the residual pressure release. Air Supply aution 1. Install an air filter (Series AFM) as a preliminary filter on the inlet side of the micro-mist separator to prevent premature clogging. Maintenance 1. Replace the element every 2 years or when the pressure drop becomes 0.1 MPa, whichever comes first, to prevent damage to the element. 1. Set the regulator while checking the displayed values of the inlet and outlet pressure gauges. Turning the knob excessively can cause damage to the internal parts. 2. The pressure gauge included with micro mist separator regulator for 0.05 to 0.2 MPa setting is for up to 0.2 MPa only. Exceeding 0.2 MPa of pressure can damage the gauge. 3. Do not use tools on the pressure regulator knob as this may cause damage. It must be operated manually. aution 1. e sure to unlock the knob before adjusting the pressure and lock it after setting the pressure. Failure to follow this procedure can cause damage to the knob and the outlet pressure may fluctuate. Mounting & Adjustment Pull the pressure regulator knob to unlock. (You can visually verify this with the orange mark that appears in the gap.) Push the pressure regulator knob to lock. When the knob is not easily locked, turn it left and right a little and then push it (when the knob is locked, the orange mark will disappear). Orange mark 2. A knob cover is available to prevent careless operation of the knob. Refer to page 14-2-6 details. 14-2-83

Series /30/40 Flow haracteristics (Representative value) ondition: Inlet pressure 0.7 MPa Rc 1/4 AWD30 Rc 3/8 Rc 1/2 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Pressure haracteristics (Representative value) onditions: Inlet pressure 0.7 MPa; Outlet pressure 0.2 MPa; Flow rate: 20 l/min (ANR) AWD30 0.25 0.25 0.25 0.20 Set point Set point Set point 0.20 0.20 0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 0.15 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 onstruction Inlet pressure (MPa) Inlet pressure (MPa) Inlet pressure (MPa) JIS Symbol w t q w t q e y r u y e r u omponent Parts No. q w Description ody onnet Replacement Parts No. Description e Valve assembly r Element assembly t Diaphragm assembly y owl O-ring u owl assembly (1) 14-2-84 Zinc die-casted Material AWD30 Aluminum die-casted Polyacetal Material Drain rass, HNR Weatherability NR NR P AWM20P-090AS AFD20P-060AS AR20P-150AS 2SFP-260S 2SF Note Platinum silver lack Part no. AWD30 AWM30P-090AS AFD30P-060AS AR30P-150AS 3SFP-260S 3SF (2) AWM40P-090AS AFD40P-060AS AR40P-150AS 4SFP-260S 4SF (2) Note 1) Including O-ring. Please contact SM regarding the bowl assembly supply for PSI and F unit specifications. Note 2) owl assembly for AWD30 and comes with a bowl guard (steel band material). Drain

O Micro Mist Separator Regulator Series /30/40 Dimensions Applicable model T N Drain A Drain AFD20 With auto-drain (N..) O S T N A S Q Pressure gauge port size S Q Metal bowl Pressure gauge port size With auto-drain (N.O./N..) K Pressure gauge (Option) Square embedded type pressure gauge (Option) Port size Min. clearance for maintenance K Pressure gauge (Option) Square embedded type pressure gauge (Option) Port size Min. clearance for maintenance Metal bowl H H J J E E M D D M V U P V racket (Option) U P AWD30, Metal bowl with level gauge racket (Option) Panel fitting dimension Y Z W Plate thickness : Max. 3.5 Panel fitting dimension Y Z With drain guide W Plate thickness AWD30: Max. 3.5 : Max. 5 Drain cock with barb fitting F.R.L. AV AU AF AR IR VEX AMR ITV I VA VE VY1 PPA AL Optional specifications O S M5 x 0.8 N.O.: lack N..: ray ø10 One-touch fitting S 1/4 Width across flats 17 arb fitting Applicable tubing: T0604 (mm) Model AWD30 Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 A 40 53 70 Standard specifications 173 201 239 73 86 92 D 52 59 75 E 40 57 73 45 50 70 With pressure gauge H 63 66 76 J 27 30.5 38.5 K 5 3.5 1.5 M 30 41 50 N 34 40 54 Accessory specifications racket mounting size P 44 46 54 Q 5.4 6.5 8.5 S 15.4 8 10.5 T 55 53 70 U 2.3 2.3 2.3 V 30 31 35.5 Panel mount W 28.5 38.5 42.5 Y 14 19 21 Z 6 7 7 With auto-drain 190 242 278 Model AWD30 Optional specifications With barb fitting With drain guide Metal bowl Metal bowl with level gauge 209 247 208 246 173 214 252 234 272 14-2-85

Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "aution", "" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS 8370 Note 2) and other safety practices. aution : Operator error could result in injury or equipment damage. : Operator error could result in serious injury or loss of life. Danger : In extreme conditions, there is a possible result of serious injury or loss of life. Note 1) ISO 4414: Pneumatic fluid power--eneral rules relating to systems. Note 2) JIS 8370: eneral Rules for Pneumatic Equipment 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or after analysis and/or tests to meet your specific requirements. The expected performance and safety assurance will be the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2. Only trained personnel should operate pneumatically operated machinery and equipment. ompressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed. 2. When equipment is to be removed, confirm the safety process as mentioned above. ut the supply pressure for this equipment and exhaust all residual compressed air in the system. 3. efore machinery/equipment is restarted, take measures to prevent shooting-out of cylinder piston rod, etc. 4. ontact SM if the product is to be used in any of the following conditions: 1. onditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis. 14-21-3

ommon Precautions e sure to read before handling. For detailed precautions on every series, refer to main text. Selection 1. onfirm the specifications. Products represented in this catalog are designed for use in compressed air appllications only (including vacuum), unless otherwise indicated. Do not use the product outside their design parameters. Please contact SM when using the products in applications other than compressed air (including vacuum). Mounting 1. Instruction manual Install the products and operate them only after reading the instruction manual carefully and understanding its contents. Also keep the manual where it can be referred to as necessary. 2. Securing the space for maintenance When installing the products, please allow access for maintenance. 3. Tightening torque When installing the products, please follow the listed torque specifications. aution Piping 1. efore piping Make sure that all debris, cutting oil, dust, etc, are removed from the piping. 2. Wrapping of pipe tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not get inside the piping. Also, when the pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. Air Supply 1. Operating fluid Please consult with SM when using the product in applications other than compressed air (including vacuum). Regarding products for general fluid, please ask SM about applicable fluids. 2. Install an air dryer, aftercooler, etc. Excessive condensate in a compressed air system may cause valves and other pneumatic equipment to malfunction. Installation of an air dryer, after cooler etc. is recommended. 3. Drain flushing If condensate in the drain bowl is not emptied on a regular basis, the bowl will over flow and allow the condensate to enter the compressed air lines. If the drain bowl is difficult to check and remove, it is recommended that a drain bowl with the auto-drain option be installed. For compressed air quality, refer to Air Preparation Equipment catalog. 4. Use clean air If the compressed air supply is contaminated with chemicals, cynthetic materials, corrosive gas, etc., it may lead to break down or malfunction. Operating Environment 1. Do not use in environments where the product is directly exposed to corrosive gases, chemicals, salt water, water or steam. 2. Do not expose the product to direct sunlight for an extended period of time. 3. Do not use in a place subject to heavy vibrations and/or shocks. 4. Do not mount the product in locations where it is exposed to radiant heat. Maintenance 1. Maintenance procedures are outlined in the operation manual. Not following proper procedures could cause the product to malfunction and could lead to damage to the equipment or machine. 2. Maintenance work If handled improperly, compressed air can be dangerous. Assembly, handling and repair of pneumatic systems should be performed by qualified personnel only. 3. Drain flushing Remove drainage from air filters regularly. (Refer to the specifications.) 4. Shut-down before maintenance efore attempting any kind of maintenance make sure the supply pressure is shut of and all residual air pressure is released from the system to be worked on. 5. Start-up after maintenance and inspection Apply operating pressure and power to the equipment and check for proper operation and possible air leaks. If operation is abnormal, please verify product set-up parameters. 6. Do not make any modifications to be product. Do not take the product apart. 14-21-4

Quality Assurance Information (ISO 9001, ISO 14001) Reliable quality of products in the global market To enable our customers throughout the world to use our products with even greater confidence, SM has obtained certification for international standards ISO 9001 and ISO 14001, and created a complete structure for quality assurance and environmental controls. SM products pursue to meet its customers expectations while also considering company s contribution in society. Quality management system ISO 9001 This is an international standard for quality control and quality assurance. SM has obtained a large number of certifications in Japan and overseas, providing assurance to our customers throughout the world. SM s quality control system Quality system education Training of suppliers Make customers our first priority, offering them reliable and friendly service. Produce the highest quality with the participation of all employees. Quality policies Market research Product planning After service Sales coordination Research Education Design Training Development Production Process control Inspection, testing, etc. Initial production control reate new products using the latest technology, and offer the finest products in a timely manner. Quality control activities New product evaluation Reliability design Reliability testing New technical development Environmental management system ISO 14001 This is an international standard related to environmental management systems and environmental inspections. While promoting environmentally friendly automation technology, SM is also making diligent efforts to preserve the environment. 14-21-5

SM Product onforming to Inter SM products complying with EN/ISO, SA/UL standards are supporting E Mark The E mark indicates that machines and components meet essential requirements of all the E Directives applied. It has been obligatory to apply E marks indicating conformity with E Directives when machines and components are exported to the member Nations of the EU. Once A manufacturer himself declares a product to be safe by means of E marking (declaration of conformity by manufacturer), free distribution inside the member Nations of the EU is permissible. E Mark SM provides E marking to products to which EM and Low Voltage Directives have been applied, in accordance with ETOP (European hydraulics and pneumatics committee) guide lines. As of February 1998, the following 18 countries will be obliged to conform to E mark legislation Iceland, Ireland, United Kingdom, Italy, Austria, Netherlands, reece, Liechtenstein, Sweden, Spain, Denmark, ermany, Norway, Finland, France, elgium, Portugal, Luxembourg E Directives and Pneumatic omponents Machinery Directive The Machinery Directive contains essential health and safety requirements for machinery, as applied to industrial machines e.g. machine tools, injection molding machines and automatic machines. Pneumatic equipment is not specified in Machinery Directive. However, the use of SM products that are certified as conforming to EN Standards, allows customers to simplify preparation work of the Technical onstruction File required for a Declaration of onformity. Electromagnetic ompatibility (EM) Directive The EM Directive specifies electromagnetic compatibility. Equipment which may generate electromagnetic interference or whose function may be compromised by electromagnetic interference is required to be immune to electromagnetic affects (EMS/immunity) without emitting excessive electromagnetic affects (EMI/emission). Low Voltage Directive This directive is applied to products, which operate above 50 VA to 1000 VA and 75 VD to 1500 VD operating voltage, and require electrical safety measures to be introduced. Simple Pressure Vessels Directive This directive is applied to welded vessels whose maximum operating pressure (PS) and volume of vessel (V) exceed 50 bar/l. Such vessels require E type examination and then E marking. 14-21-6

national Standards SM Product onforming to International Standards you to comply with E directives and SA/UL standards. Mark of compliance for SA/UL Mark of compliance for SA SA Standards & UL Standards UL and SA standards have been applied in North America (U.S.A. and anada) symbolizing safety of electric products, and are defined to mainly prevent danger from electric shock or fire, resulting from trouble with electric products. oth UL and SA standards are acknowledged in North America as the first class certifying body. They have a long experience and ability for issuing product safety certificate. Products approved by SA or UL standards are accepted in most states and governments beyond question. Since SA is a test certifying body as the National Recognized Testing Laboratory (NRTL) within the jurisdiction of Occupational Safety and Health Administration (OSHA), SM was tested for compliance with SA Standards and UL Standards at the same time and was approved for compliance with the two Standards. The above SA NRTL/ logo is described on a product label in order to indicate that the product is approved by SA and UL Standards. TSSA (MR) Registration Products TSSA is the regulation in Ontario State, anada. The products that the operating pressure is more than 5 psi (0.03 MPa) and the piping size is bigger than 1 inch. fall into the scope of TSSA regulation. Products conforming to E Standard With E symbol for simple visual recognition In this catalog each accredited product series is indicated with a E mark symbol. However, in some cases, every available models may not meet E compliance. Please visit our web site for the latest selection of available models with E mark. http://www.smcworld.com 14-21-7

SM s lobal Service Network America U.S.A. SM orporation of America 3011 North Franklin Road Indianapolis, 46226, U.S.A. TEL: 317-899-4440 FAX: 317-899-3102 ANADA SM Pneumatics (anada) Ltd. 6768 Financial Drive Mississauga, Ontario, L5N 7J6 anada TEL: 905-812-0400 FAX: 905-812-8686 MEXIO SM orporation (Mexico), S.A. DE.V. arr. Silao-Trejo K.M. 2.5 S/N, Predio San Jose del Duranzo.P. 36100, Silao, to., Mexico TEL: 472-72-2-55-00 FAX: 472-72-2-59-44/2-59-46 HILE SM Pneumatics (hile) S.A. Av. La Montaña 1,115 km. 16,5 P. Norte Parque Industrial Valle rande, Lampa Santiago, hile TEL: 02-270-8600 FAX: 02-270-8601 ARENTA SM Argentina S.A. Teodoro arcia 3860 (1427) uenos Aires, Argentina TEL: 011-4555-5762 FAX: 011-4555-5762 OLIVIA SM Pneumatics olivia S.R.L. Avenida eni Numero 4665 Santa ruz de la Sierra-asilla de orreo 2281, olivia TEL: 591-3-3428383 FAX: 591-3-3449900 VENEZUELA SM Neumatica Venezuela S.A. Apartado 40152, Avenida Nueva ranada, Edificio Wanlac, Local 5, aracas 1040-A, Venezuela TEL: 2-632-1310 FAX: 2-632-3871 PERU (Distributor) IMPEO Automatizacion Industrial S.A. AV. anevaro 752, Lince, Lima, Peru TEL: 1-471-6002 FAX: 1-471-0935 URUUAY (Distributor) AKO S.A. alicia 1650 esq. aboto.p. 11200, Montevideo, Uruguay TEL: 2-401-6603 FAX: 2-409-4306 RAZIL SM Pneumaticos Do rasil Ltda. Rua. Dra. Maria Fidelis, nr. 130, Jardim Piraporinha-Diadema-S.P. EP: 09950-350, rasil TEL: 11-4051-1177 FAX: 11-4071-6636 OLOMIA (Distributor) Airmatic Ltda. alle 18 69-05 Apart. Aereo 081045 Santa Fe de ogotá, olombia TEL: 1-424-9240 FAX: 1-424-9260 Europe U.K. SM Pneumatics (U.K.) Ltd. Vincent Avenue, rownhill, Milton Keynes, MK8 0AN, ackinghamshire, U.K. TEL: 01908-563888 FAX: 01908-561185 ERMANY SM Pneumatik mbh oschring 13-15 D-63329 Egelsbach, ermany TEL: 06103-4020 FAX: 06103-402139 ITALY SM Italia S.p.A. Via aribaldi 62 I-20061 arugate Milano, Italy TEL: 02-9271365 FAX: 02-9271365 FRANE SM Pneumatique S.A. 1 oulevard de Strasbourg, Parc ustave Eiffel, ussy Saint eorges, F-77600 Marne La Vallee edex 3 France TEL: 01-64-76-10-00 FAX: 01-64-76-10-10 SWEDEN SM Pneumatics Sweden A Ekhagsvägen 29-31, S-141 05 Huddinge, Sweden TEL: 08-603-07-00 FAX: 08-603-07-10 SWITZERLAND SM Pneumatik A Dorfstrasse 7, Postfach 117, H-8484 Weisslingen, Switzerland TEL: 052-396-3131 FAX: 052-396-3191 AUSTRIA SM Pneumatik mbh (Austria) irakstrasse 8, A-2100 Korneuburg, Austria TEL: 0-2262-6228-0 FAX: 0-2262-62285 SPA SM España, S.A. Zuazobidea 14 Pol. Ind. Júndiz 01015 Vitoria, Spain TEL: 945-184-100 FAX: 945-184-510 IRELAND SM Pneumatics (Ireland) Ltd. 2002 itywest usiness ampus, Naas Road, Saggart, o. Dublin, Ireland TEL: 01-403-9000 FAX: 01-466-0385 NETHERLANDS (Associated company) SM Pneumatics V De Ruyterkade 120, NL-1011 A Amsterdam, Netherlands TEL: 020-5318888 FAX: 020-5318880 REEE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, reece TEL: 01-3426076 FAX: 01-3455578 DENMARK SM Pneumatik A/S Knudsminde 4 DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 14-21-20

SM s lobal Service Network Europe FLAND SM Pneumatics Finland OY PL72, Tiistinniityntie 4, SF-02231 ESP00, Finland TEL: 09-8595-80 FAX: 09-8595-8595 NORWAY SM Pneumatics Norway A/S Vollsveien 13, ranfoss Næringspark N-1366 LYSAKER, Norway TEL: 67-12-90-20 FAX: 67-12-90-21 ELIUM (Distributor) SM Pneumatics N.V./S.A. Nijverheidsstraat 20-2160 Wommelgem elguim TEL: 03-355-1464 FAX: 03-355-1466 POLAND SM Industrial Automation Polska Sp.z.o.o. ul. Konstruktorska 11A, PL-02-673 Warszawa, Poland TEL: 022-548-5085 FAX: 022-548-5087 TURKEY (Distributor) Entek Pnömatik San.ve Tic. Ltd. Sti Perpa Tic. Merkezi Kat:11 No.1625 80270 Okmeydani Istanbul, Türkiye TEL: 0212-221-1512 FAX: 0212-221-1519 RUSSIA SM Pneumatik LL. 36/40 Sredny prospect V.O. St. Petersburg 199004, Russia TEL: 812-118-5445 FAX: 812-118-5449 ZEH SM Industrial Automation Z s.r.o. Hudcova 78a, Z-61200 rno, zech Republic TEL: 05-4121-8034 FAX: 05-4121-8034 HUNARY SM Hungary Ipari Automatizálási kft. udafoki ut 107-113 1117 udapest TEL: 01-371-1343 FAX: 01-371-1344 ROMANIA SM Romania S.r.l. Str. Frunzei, Nr. 29, Sector 2, ucharest, Romania TEL: 01-3205111 FAX: 01-3261489 SLOVAKIA SM Priemyselná automatizáciá, s.r.o Nova 3, SK-83103 ratislava TEL: 02-4445-6725 FAX: 02-4445-6028 SLOVENIA SM Industrijska Avtomatilca d.o.o. rajski trg 15, SLO- 8360 Zuzemberk, Slovenia TEL: 07388-5240 FAX: 07388-5249 SH AFRIA (Distributor) Hyflo Southern Africa (Pty.) Ltd. P.O.ox 240 Paardeneiland 7420 South Africa TEL: 021-511-7021 FAX: 021-511-4456 EYPT (Distributor) Saadani Trading & Ind. Services 15 Sebaai Street, Miami 21411 Alexandria, Egypt TEL: 3-548-50-34 FAX: 3-548-50-34 Oceania/Asia AUSTRALIA SM Pneumatics (Australia) Pty.Ltd. 14-18 Hudson Avenue astle Hill NSW 2154, Australia TEL: 02-9354-8222 FAX: 02-9894-5719 NEW ZEALAND SM Pneumatics (New Zealand) Ltd. 8 Sylvia Park Road Mt.Wellington Auckland, New Zealand TEL: 09-573-7007 FAX: 09-573-7002 TAIWAN SM Pneumatics (Taiwan) o.,ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 HON KON SM Pneumatics (Hong Kong) Ltd. 29/F, lifford entre, 778-784 heung, Sha Wan Road, Lai hi Kok, Kowloon, Hong Kong TEL: 2744-0121 FAX: 2785-1314 SAPORE SM Pneumatics (S.E.A.) Pte. Ltd. 89 Tuas Avenue 1, Jurong Singapore 639520 TEL: 6861-0888 FAX: 6861-1889 PHILIPPES SHOKETSU SM orporation Unit 201 ommon oal Tower, Madrigal usiness Park, Ayala Alabang Muntinlupa, Philippines TEL: 02-8090565 FAX: 02-8090586 MALAYSIA SM Pneumatics (S.E.A.) Sdn. hd. Lot 36 Jalan Delima1/1, Subang Hi-Tech Industrial Park, atu 3 40000 Shah Alam Selangor, Malaysia TEL: 03-56350590 FAX: 03-56350602 SH KOREA SM Pneumatics Korea o., Ltd. Woolim e-iz enter (Room 1008), 170-5, uro-dong, uro-u, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 HA SM (hina) o., Ltd. 7 Wan Yuan St. eijing Economic & Technological Development Zone 100176, hina TEL: 010-67882111 FAX: 010-67881837 THAILAND SM Thailand Ltd. 134/6 Moo 5, Tiwanon Road, angkadi, Amphur Muang, Patumthani 12000, Thailand TEL: 02-963-7099 FAX: 02-501-2937 DIA SM Pneumatics (India) Pvt. Ltd. D-107 to 112, Phase-2, Extension, Noida, Dist. autaim udh Nagar, U.P. 201 305, India TEL: (0120)-4568730 FAX: 0120-4568933 DONESIA (Distributor) P.T. Riyadi Putera Makmur Jalan Hayam Wuruk Komplek lodok Jaya No. 27-28 Jakarta 11180 Indonesia TEL: 021-625 5548 FAX: 021-625 5888 PAKISTAN (Distributor) Jubilee orporation First Floor Mercantile entre, Newton Road Near oulton Market P.O. ox 6165 Karachi 74000 Pakistan TEL: 021-243-9070/8449 FAX: 021-241-4589 ISRAEL (Distributor) accara Automation ontrol Kvutzat eva 18915 Israel TEL: 04-653-5960 FAX: 04-653-1445 SAUDI ARAIA (Distributor) Assaggaff Trading Est. P.O. ox 3385 Al-Amir Majed Street, Jeddah-21471, Saudi Arabia TEL: 02-6761574 FAX: 02-6708173 14-21-21