D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

Similar documents
E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

E 212 E 222 Tank top mounting Connection up to G1¼ Nominal flow rate up to 220 l/min

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

Change-Over Pressure Filter DFDK

D e s c r i p t i o n

MPS/MST SPIN - ON FILTER SUCTION - RETURN SERIES. Maximum working pressure 12 bar. Flow rates to 300 l/min

Pressure reducing valve, pilot operated

Pressure reducing valve, pilot operated, Model 3DR

Flow rates to 200 l/min

Check valve hydraulically pilot operated

Pressure relief valve, direct operated

3-Way Pressure-Reducing Cartridge, Size 2 4

SPM. Pressure Filters MEDIUM PRESSURE INLINE FILTER

Pilot operated pressure relief valve sandwich plate,type ZDB/Z2DB6 Huade América 1

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

3-Way Safety Block DSV

Fixed Displacement Motor A4FM

Inverse Proportional Pressure-Relief Cart., Size 2 4

LMP 110 Maximum pressure 80 bar F l o w r a t e s t o l / m i n

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

RE / Meter out pressure compensator Sandwich plate design Type SCA... /Series 2X. Description of function, Section 1/6. Replaces: 09.

Proportional Pressure-Relief Cartridge Valve, Size 2...4

EXH. Specifications. Descriptions. Min. working pressure MPa

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Inverse Prop. Pressure-Relief Cart., Size 2 4

Inverse Proportional Pressure-Relief Cart., Size 2 4

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Air preparation units

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Pressure-Relief Cartridge Valve, Size 4

Pressure relief valve, direct operated

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

2-way flow control valve Model 2FRM 6

Pressure reducing valve, direct operated

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Fixed Displacement Plug-In Motor A2FE

BS ml Bottle Sampling Unit

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

PRESSURE SEQUENCE VALVE TYPE UZK

Proportional Throttle Cartridges, Size 16

Technical Data Sheet TI-F50 Locking Units series KFH

Double throttle/check valve, Type Z2FS Series 30 Huade América 1

Pilot Check Valve: Metal Body Type

ISO INTERNATIONAL STANDARD. Hydraulic fluid power Filter elements Determination of resistance to flow fatigue using high viscosity fluid

Wide opening parallel grippers Series CGLN

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

Fuel Filters DN15 DN25. elektrogas.com DE

Desiccant Air Breathers DBE. Section 3: TNK SCHROEDER INDUSTRIES ACCESSORIES 21

Safety and Shut-off Block SAF/DSV

Pressure reducing valve, direct operated

Bores: ø 10, 16, 20, 25, 32 mm

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Explanations hydraulic valves TECHNICAL EXPLANATIONS HYDRAULIC VALVES. Contents. 1. Foreword. 2. Characteristic Values

Cooler-Bypass Thermostat Valve, Size 16

Pressure relief valves

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

Safety and Shut-off Block SAF/DSV

PLD 03 T A CASAPPA S.p.A.

Electrically Operated Pressure-Relief Cartridge, Size 10

Fixed Displacement Motor A4FM

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

Variable Displacement Pump A10VO

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Inverse Proportional Pressure-Relief Cartridge, Size 10

4/2 way Pneumatic Solenoid Valve

SOLENOID VALVES AND PNEUMATIC VALVES

Compressed Air Cleaning Filter Series

OPCom With laser diode Measurement range 4, 6,14 and 21 µm(c) Operating pressure up to 500 bar

D62 - D63 Directional Control Valve l/min

Gas Filters DN15 DN300. elektrogas.com EE151 06/13

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Two-stage valve type NE

Series K Air service units G 1/8, G 1/4

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Diaphragm Accumulators

Spin-On Filters SSF 24,25

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Intrinsically safe solenoid valves on/off controls - ATEX certification

Pressure reducing/relief valve, pilot operated type UZCP10

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

Compressed Air Conditioning Catalog Chapter I

Axial piston pumps type PVC

Axial piston pumps type PVC

SATURNSERIES INTERCHANGE > ISO (for the couplings)

Double Pilot Operated Cartridge Check Valve, Size 8

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

Tank top return line filter Pi 500

Continuous Oil Condition Monitoring

4/3 Directional valve elements L8_P5 with proportional (ED-IP) control and with or without LS connections L8_P5 (ED-IP)

Transcription:

Pressure Filters D D 6 In-line mounting Operating pressure up to 1 bar Nominal flow rate up to 9 l/min Description Application In the pressure circuits of hydraulic and lubrication systems. Performance features Protection against wear: By means of filter elements that, in full-flow filtration, meet even the highest demands regarding cleanliness classes. Protection against malfunction: Through installation near to the control valves or other expensive components. The specific determined flow rate guarantees a closed by-pass valve even at ν mm /s (cold start condition). Pressure Filter D Filter elements Flow direction from outside to centre. The star-shaped pleating of the filter material results in: large filter surfaces low pressure drop high dirt-holding capacities long service life Filter maintenance By using a clogging indicator the correct moment for maintenance is stated and guarantees the optimum utilization of the filter life. Materials Filter head: Filter bowl: Seals: Filter media: Aluminium alloy Aluminium alloy NBR (FPM on request) EXAPOR MAX - inorganic multi-layer microfibre web Paper - cellulose web, impregnated with resin Accessories Electrical and/or optical clogging indicators are available - optionally with one or two switching points resp. temperature suppression. Dimensions and technical data see catalogue sheet 6.. Subject to change.1-e 15 Page 1

Characteristics Operating pressure... 6 bar, min. x 1 6 pressure cycles Nominal pressure according to DIN 55... 1 bar, min. 1 pressure cycles Quasi-static operating pressure Permissible pressures for other numbers of cycles Operating pressure p [bar] 1 75 5 1 1 1 5 1 6 1 7 1 8 Nominal flow rate Number of cycles n Up to 9 l/min (see Selection Chart, column ) The nominal flow rates indicated by ARGO-HYTOS are based on the following features: closed by-pass valve at ν mm /s element service life > 1 operating hours at an average fluid contamination of,7 g per l/min flow volume flow velocity in the connection lines: up to 1 bar 6 m/s Filter fineness 5 µm(c)... µm(c) β-values according to ISO 16889 (see Selection Chart, column and diagram Dx) Dirt-holding capacity Values in g test dust ISO MTD according to ISO 16889 (see Selection Chart, column 5) Hydraulic fluids Mineral oil and biodegradable fluids (HEES and HETG, see info-sheet.) Temperature range - C... +1 C (temporary - C... +1 C) Viscosity at nominal flow rate at operating temperature: ν < 6 mm /s as starting viscosity: ν max = 1 mm /s at initial operation: The recommended starting viscosity can be read from the diagram D (pressure drop as a function of the kinematic viscosity) as follows: Find the 7 % p of the cracking pressure of the by-pass valve on the vertical axis. Draw a horizontal line so that it intersects the p curve at a point. Read this point on the horizontal axis for the viscosity. Mounting position Preferably vertical, filter head on top Connection Threaded ports according to ISO 8 or DIN 1. Sizes see Selection Chart, column 6 (other port threads on request). Page Subject to change.1-e 15

Diagrams p-curves for complete filters in Selection Chart, column D1 flow volume at ν = 5 mm /s ( = casing empty) kinematic viscosity at nominal flow, 1,5 1,,5 D 1+5 +6 1 8 6 1 1 5 6 5+6 1 5 6 8 1 Q [l/min] ν [mm /s] D flow volume at ν = 5 mm /s ( = casing empty) kinematic viscosity at nominal flow, 1,5 1,,5 D 6 1+5 +6 1 8 6 1 5 6 6 8 1 6 8 1 Q [l/min] ν [mm /s] Filter fineness curves in Selection Chart, column Dx Filtration ratio β as a function of particle size x obtained by the Multi-Pass-Test according to ISO 16889 The abbreviations represent the following β-values resp. finenesses: Filtration ratio β for particles > x µm Efficiency [%] For EXAPOR MAX and Paper elements: 5EX = β 5 (c) = EXAPOR MAX 7EX = β 7 (c) = EXAPOR MAX 1EX = β 1 (c) = EXAPOR MAX 16EX = β 16 (c) = EXAPOR MAX P = β (c) = Paper Based on the structure of the filter media of the P paper elements, deviations from the printed curves are quite probable. For special applications, finenesses differing from these curves are also available by using special composed filter media. Particle size x [µm] (for particles larger than the given particle size x) Subject to change.1-e 15 Page

Selection Chart Part No. Nominal flow rate Pressure drop see diagram D/curve no. Filter fineness see diagr. Dx Dirt-holding capacity Connection A/B Cracking pressure of by-pass Symbol l/min g bar kg 1 5 6 7 8 9 1 11 1 D -15 16 D1/1 5EX,9 G½,5 V.51-,8 optional - D -156 7 D1/ 1EX 6,8 G½,5 V.51-6,8 optional - D -158 D1/ 16EX 6,9 G½,5 V.51-8,8 optional - Weight Replacement filter element Part No. Clogging indicator Remarks D -151 D1/ P,6 G½,5 P.51-11*,8 optional - D -18 D1/5 5EX,9 G½ 7 V.51-,8 optional - D -186 D1/6 1EX 6,8 G½ 7 V.51-6,8 optional - D 6-15 D/1 5EX 1 G½,5 V.5-1,1 optional - D 6-156 57 D/ 1EX 1 G¾,5 V.5-6 1,1 optional - D 6-158 9 D/ 16EX 15 G¾,5 V.5-8 1,1 optional - D 6-151 8 D/ P 7,1 G¾,5 P.5-1* 1,1 optional - D 6-18 8 D/5 5EX 1 G½ 7 V.5-1,1 optional - D 6-196 8 D/6 1EX 1 G¾ 7 V.5-6 1,1 optional - * Paper media supported with metal gauze Optical or electrical indicators are available to monitor the clogging condition of the element. If the indicator should be already mounted onto the filter head use the abbreviation M behind the part number of the indicator. The printed order acknowledgements show both items separately. Order example: The filter D -156 has to be supplied with optical clogging indicator - response pressure, bar Order description: D -156 / DG -1 M Part No. (Basic unit) Clogging indicator For the appropriate clogging indicators see catalogue sheet 6. Mounted Remarks: The switching pressure of the clogging indicator has always to be lower than the cracking pressure of the by-pass valve (see Selection Chart, column 7). The filters listed in this chart are standard filters. Other designs available on request. Page Subject to change.1-e 15

Dimensions Clogging indicator optional: Pressure holes plugged with screws M DG 1 S Minimum distance from ferromagnetic parts: 7 mm G T E U ØC A B ØC F ØR D ØH K L P N O V P 1 P W M Q Measurements Type A/B C D E F G H I K L M Ø/depth N O P Q R S T U V W D G½ 9 18 7 5,5 8 58,5 55 7 5 M6/8 AF 6 19 15 7 81 55 5,5 D 6 G½, G¾ 9 7 5,5 8 58,5 55 7 5 M6/8 AF6 19 15 7 81 55 5,5 Symbols 1 5 6 7 P 1 P 1 P P Subject to change.1-e 15 Page 5

Spare Parts 5 Pos. Designation Part No. 1 Filter bowl D D.11 1 Filter bowl D 6 D 6.11 O-ring 5 x N7.51 Filter element (with seal) s. Chart / col. 9 Hexagonal head screw M x 8 DIN 9-8.8 11858 5 Bonded Seal,1 x 7, x 1 156 The functions of the complete filters as well as the outstanding features of the filter elements assured by ARGO-HYTOS can only be guaranteed if original ARGO-HYTOS spare parts are used. 1 Quality Assurance Quality management according to DIN EN ISO 91 To ensure constant quality in production and operation, ARGO-HYTOS filter elements undergo strict controls and tests according to the following ISO standards: ISO 91 ISO 9 ISO 9 ISO 968 ISO 16889 ISO 181 Verification of collapse/burst pressure rating Verification of fabrication integrity (Bubble Point Test) Verification of material compatibility with fluids Evaluation of pressure drop versus flow characteristics Multi-Pass-Test (evaluation of filter fineness and dirt-holding capacity) Determination of resistance to flow fatigue using high viscosity fluid Before release into the series production the filter casing is tested for fatigue strength in our pressure pulse test rig. Various quality controls during the production process guarantee the leakfree function and solidity of our filters. Illustrations may sometimes differ from the original. ARGO-HYTOS is not responsible for any unintentional mistake in this specification sheet. Page 6 Subject to change.1-e 15