SYSCO BUCKHEAD BEEF COLLEGE PARK, GEORGIA

Similar documents
SYSCO BUCKHEAD BEEF CHARLOTTE, NORTH CAROLINA

SYSCO ST JOHN'S MOUNT PEARL, NEWFOUNDLAND

SIDEWINDER DRILLING RIG 122 CLEBURNE COUNTY, ARKANSAS

SYSCO ALLARD VILLE DE QUEBEC, QUEBEC, CANADA

PAVESTONE COMPANY CST PAVERS PEDRICKTOWN, NEW JERSEY

BUZZI UNICEM USA PENSACOLA TERMINAL MILTON, FLORIDA

SYSCO FOODS BAHAMAS FOOD SERVICE NASSAU, BAHAMAS

Infrared Thermography Inspection Guidelines. Date Issued:

You Just Experienced an Electrical Failure, What Should You Do Next? By Don Genutis Hampton Tedder Technical Services

Selection of Electrical PPE Tables

R E D I C O N T R O L S

Innovative Techniques for Mitigating Arc Flash Exposure

ELECTRICAL (COMPREHENSIVE) SAFETY PROGRAM REGULATORY STANDARD: OSHA - 29 CFR CFR , ,

ELECTRIC OPERATING PROCEDURES Date: 11/01/06

THE OSHA LOCK-OUT/TAG-OUT STANDARD

AE R1 February 2015

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)

Monitoring transformers with infrared cameras

Pixel Thermographics Ltd. Compressed Air Leak Detection Survey SAMPLE REPORT. Pixel Thermographics Ltd

Pool Inspection. Your Street San Diego, California Prepared for: Your Name Prepared by: Priority Inspection Service

Electrical Safety PPT-SM-ELECTSFTY V.A.0.0

Preparer: Owner: Approver: EHS Team Member TES Manager Site Manager

Ground Fault Circuit Interrupter(GFCI) Policy

It is essential that the maintenance staff is qualified for electrical works and follows safety procedures.

2017 NWHA TECHNICAL SEMINAR. Arc Flash Hazard Awareness MIKE BRENDLE LLC

120 PSI FAST-FILL AIR SOURCE KIT 25% Duty Compressor on 1.5 Gallon Air Tank

Electrical. Version 1.0

COOPER POWER SERIES. Under-oil arrester disconnector installation/operation instructions. OEM Equipment MN800010EN

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

Additions, Revisions, or Updates

Guidelines to the standard IEC60601

Power Supply Facilities Failure (Units 3-4 Temporary M/C (A), etc.) March 22, 2013 Tokyo Electric Power Company

MISSOURI UNIVERSITY OF SCIENCE & TECHNOLOGY Procedure: 3.6

Protection of motor circuits

Leader s Guide ERI Safety Videos

Operating Instructions for BAIR22-6 AIR-POWERED CRIMPING TOOL

Lockout/Tagout Training Overview. Safety Fest 2013

Appendix A: Energized Work Permit

Hazardous Energy Control/Lockout

Operating Manual. Model BAC-30RT30/BAC-30DC

USER MANUAL. JET TST and JET TST S.

Inspection Recommendations

Inoxair. Repair Manual. Content. Edition: 12/2010. Subject to technical changes for reasons of the continous development.

Energy Control. Suite 2A, 55 Frid Street Hamilton, ON L8P 4M3 office: cell:

to the 2009 Edition Standards & Codes Introduction Background Byron Jordan Sr. Field Engineer

Leader s Guide ERI Safety Videos

Lockout/Tagout - Energy Control Program

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

AR740 RPS Redundant Power Supply Quick Install Guide

COOPER POWER SERIES. D-73P3 bypass switches installation instructions. Switches MN008005EN. Effective April 2016 Supersedes S June 2013

COOPER POWER SERIES. 200 A 15, 25, and 35 kv class portable feedthru installation instructions. Loadbreak Apparatus Connectors MN650037EN

Electrical Safety Program

Product Overview. Product Description CHAPTER

Operating Instructions

Effective March 2015 Supersedes S August 2002

Development and Evolution of an Asset Management Organization

COOPER POWER SERIES. 200 A 15, 25, and 35 KV class insulated standoff bushing installation instructions. Loadbreak Apparatus Connectors MN650039EN

DEH Instructions. Three-Phase, Platform-Mounted Distribution Transformers

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

Maintenance handbook

Operating Manual. Models AQT-02 & AQT-COO2 Manual No. MON004 (Rev 2 April 2000)

Management Plan for Electrical Safety ISD #535

Installation and Maintenance Instructions for F5509/F6509 Differential Pressure Gauges

: Electric Power Generation, Transmission, and Distribution. Region IV - OSHA

Instructions for Safe Use

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Major Changes. Standard. TECH TOPIC standards and. By Peter Walsh, PE

Gas Network Craftsperson

HAS2400 Hepa Air Scrubber

SIX R (P ) AND SEVEN R (P ) POSITION CYLINDERS Service Information

OPERATION MANUAL ID900

NIOSH Task Number 18388

Electrical Safety Program

Mini Pod Press. #78H-M2 Mini Pod Press Manual-R1

Installation, Operation and Maintenance Instructions for Electronically Controlled Pressurisation Units

[ACT 005] Manual E 5/25/05 9:24 PM Page 3 MULTI-FUNCTION

Sterile Visual Flow Indicator

Installation Instructions for the Walking Beam Interlock for Eaton EHD, FDB, FD, HFD, FDC, FW, HFW, FWC, Circuit Breakers and Molded Case Switches

Why do I need to do an Arc-Flash Analysis?

Arc Flash 101. presented by Arc Flash Blaster LLC

Instruction Manual LIMITED 1 YEAR WARRANTY. Hydraulic Punch Driver Read this material before using this product.

COOPER POWER SERIES. 600 A, 15, 25, and 35 kv Class Cleer Grounding Elbow Installation Instructions. Loadbreak Apparatus Connectors MN650056EN

SECTION 51 NFPA 70E POLICY. Health & Safety Policy and Procedures Manual

INSTALLATION GUIDE Gas Rangetops

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

Air Tractor Preventative Maintenance Manual And Troubleshooting

Big 5 Site Training Support Information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

Preview to the 2018 NFPA 70E, the Standard for Electrical Safety in the Workplace

2 GAL AIR COMPRESSOR OPERATOR S MANUAL 1/3HP/2-GALLON IMPORTANT: READ THIS OPERATOR S MANUAL BEFORE USING

USER MANUAL ELECTRIC BLOWBACK SYSTEM

This presentation provides an overview of modern methods for minimizing the arc-flash hazard.

Concentrate Distribution System (Stand Mounted) A-CDS-70-X & A-CDS-TANK-X-ST Industrial Drive, Orlinda, TN 37141

Evaluation of Effectiveness and Safety of CO 2 Cleaning of Energized Contaminated Pad-Mounted Gear

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

The University of Georgia Automated External Defibrillator (AED) Program Guidelines

SERVICE & MAINTENANCE MANUAL FOR:

! Warning, refer to accompanying documents.

Transcription:

SYSCO BUCKHEAD BEEF COLLEGE PARK, GEORGIA June, 2016 Infrared Inspection Report Sysco Buckhead Beef 4500 Wickersham Drive College Park, Georgia, 30337 Company Contact: Richard Blahnik Project: 05220616 2605 CHARTER OAK DRIVE, LITTLE ROCK, AR 72227 PHONE: 800-737-1787 & 501-228-5001 FAX: 501-228-5001 EMAIL: Logistics@usscanman.com

ORDER OF REPORT CONTENTS 1: Data To Facilitate Understanding & Utilizing Scan Report 2: Scan Results Overview & Action Taken Form 3: Identified Faulting Conditions, Information & Photographs 4: List Of Facility Equipment Identified By The Customer Representative & Notations Of Faulting Conditions Found DISCLAIMER This report and the recommendations contained in it are based upon conditions and practices observed and information made available to United Spectrographics personnel. This report does not purport to list all hazards or faulty conditions. It is not intended to indicate that other hazards or faulty conditions do not exist. Severity ratings in the report are based on the criteria shown in this report and are intended as guidelines only. No responsibility is assumed for the control of the facility s condition, maintenance practices or correction of conditions indicated herein. By issuing this report, neither United Spectrographics nor any of its employees makes any warranty, expressed or implied, concerning the contents of this report. Furthermore, neither United Spectrographics nor any of its employees shall be liable in any manner (other than liability that may be expressed in any policy of insurance that may be issued by United Spectrographics) for personal injury or property damage or loss of any kind arising from or connected with this inspection or failure to inspect.

Utilizing Report Contents Included in this report are Photographs and Thermographs of problem areas found during our recent Infrared Inspection of your facility. Each problem area picture is accompanied by: Date Location Information Temperature Calculations Color-coded Temperature Intensity and/or Condition Significance Data A Brief Comment Relating The Item In The Photograph To Its Corresponding Thermograph Suggested Corrective Recommendations. In most cases, problems (faults) found will be listed according to the date and order that they were located, rather then by significance or priority, as we feel that you and/or your personnel can best judge this, keeping in mind circuit importance and thermograph intensity. Thermal intensity is indicated by use of a color-coded data inserts that locate a fault s position on the standard electrical failure curve. The color of the insert represents the temperature range of the hottest item, or a portion of the item's circuitry, pointed out in the thermograph. The temperature ranges which the colored inserts represent are grouped as follows: INSERT Red Orange Yellow Green Temperature Range 70ºC/126ºF and higher above Ambient Operating Temp. 40ºC/72ºF to 69ºC/124ºF above Ambient Operating Temp. 25ºC/45ºF to 39ºC/70ºF above Ambient Operating Temp. *10ºC/18ºF to 24ºC/43ºF above Ambient Operating Temp. ( * See page 4)

Determining Cost Effective Responses Electrical equipment failures generally follow a standard mechanical/electrical failure curve. Dividing the failure curve into temp. ranges and locating a problems position on the curve allows us to indicate the probable time to its failure. Knowing a problems probable time to failure allows you to make a cost effective response to the problem areas that we locate. Below is a depiction of the electrical fault failure curve with the thermal intensity ranges and the colors that we assign to faults detailed in our reports. STANDARD ELECTRICAL FAULT FAILURE CURVE (Does Not Include Area In Blue) MINOR INTERMEDIATE SERIOUS CRITICAL DEVICE TEMP IS AMBIENT, BUT DEVICE IS EITHER FAULTY OR UNSAFE. 10ºC * 18ºF 25ºC 45ºF 40 C 72ºF 70 C 126ºF AMBIENT TEMP YEARS MONTHS MONTHS TO WEEKS WEEKS TO NOW FAULTY EQUIP Built In Trend Monitoring When yearly scans are accomplished, report results allow you to trend monitor your electrical equipment without having to cross reference previous report findings. If a previous years problem is not repaired it will show up again in the current scan report and its current intensity range indicates a current effective response.

Defining Total Temperature and Ambient Operating Temperature And Explanation For Their Use Total Temperature: Total Temperature = Ambient Operating Temperature + Fault temperature Allows you, the customer, to evaluate possible damage to equipment. Leads fail between 90ºC/194ºF and 110ºC/230º Phenolic fails around 200ºC/392ºF Transformers and Motor Insulation failure temperature depends on insulation class rating. Contacts start to fail around 130ºC/266ºF Ambient Operating Temperature (AOT*) for Infrared Scanning Purposes: Temperature within a device container (Box or Cabinet) that is not directly affected by faulting component = Normal Equipment Operating Temperature Contained By Box or Cabinet. If there is no container (Example: Device mounted to a wall) it is the temperature adjacent to the device not affected by the fault. Allows you, the customer, to determine if device will operate at intended amperage. Most switchgear is rated to operate at approximately 40ºC/104ºF (Industrial) to 50ºC/122ºF (Marine) If AOT is enough above normal rated temperature, either of the following conditions can cause an unanticipated trip. 1. An intermittent high load. 2. A minor (Green) or intermediate (Yellow) fault. Report pages with photographs: PH stands for Visible Light Photograph TH stands for Infrared Light Thermograph *AOT stands for Ambient Operating Temperature Both black & white and color infrared thermographs are presented to better depict the fault condition.

In addition to the corrective response time frame suggested below and the failure curve located on the previous page, you may want to consider using the military standard responses presented below. Military Standard For Evaluating Faults Located In Electrical Equipment Utilizing Temperature Data Obtained With Infrared Imaging Equipment: Temperatures rise above Ambient Operating Temperature: *10ºC/18ºF to 24ºC/43ºF component failure unlikely, but corrective measures required at next scheduled routine maintenance period or as scheduling permits. (Green Label) 25ºC/45ºF to 39ºC/70ºF component failure probable, unless corrected. (Yellow Label) 40ºC/72ºF to 69ºC/124ºF component failure almost certain, unless corrected. (Orange Label) 70ºC/126ºF and above component failure imminent. Immediately inform the person responsible for continued operation of equipment. (Red Label) Note: United Spectrographics uses a Blue Label to indicate faults that require attention due to either ambient temperature (Ex: Phase Not Operating), faulty equipment elements or unsafe conditions. * Note: Temperature conditions below 10ºC/18ºF rise above AOT are not considered significant enough to record and are usually not included in the reports unless the fault temperature is being affected by a cooling medium such as oil or wind. Fault Correction Recommendation When Our Source Assessment Is Inaccurate: When a fault is indicated in a connection or component and examination by your electrician does not turn up a loose connection or faulty component where we have indicated, a fault does exist. The electrician should continue to investigate the next connection or component to be found in the direction that the heat is coming from until a source is located. Example: If a molded case breaker line side lead connection lug is indicated as a fault source and is found to be secure, but not frozen in place, look for a loose connection or sign of over temp. in the lead holder lug.

SCAN RESULTS OVERVIEW PROMPT ATTENTION ITEMS: Because of: 1. The intensity or heat level indicated at the time of the scan. 2. Deterioration caused by excessive temperature not present at the time of the scan. 3. Physical condition irregularities observed at the time of the scan. We recommend that the following faults be given prompt attention: Faults: #1*. #2 Items With Asterisks Have High Total or Ambient Operating Temperatures. United Spectrographics June, 2016

SUMMARY OF FINDINGS FAULTS BY CATEGORY NUMBER OF FAULTS FAULT NO./ITEM NO. MINOR 0 0 INTERMEDIATE 0 0 SERIOUS 1 2/57 CRITICAL 1 1/56 SERIOUS 0 0 Number of items located at facility: 70 Number of faults: 2

ACTION TAKEN Sysco Buckhead Beef College Park, Georgia June, 2016 Fault # Item # Category Repaired Monitor Date Name 1 56 Critical 2 57 Serious

PROJECT: 05220616 CUST REP: SCAN REP: Ash Trey Dent DATE: 06/22/2016 LOCATION: Main Electric Room Box Labeled: ATS-2 Transfer Switch Normal Power Connections PH # 1 > ITEM: SOURCE: TEMP: Aø of Transfer Switch Line side lead connection lug. Temp. of connection and lug is:: 218ºC / 424ºF Total Temp - 45ºC / 113ºF AOT = 173ºC / 311ºF above AOT. Note: Connections show heat discoloration and insulation is cracked and melted TH # 1 > COMMENTS Abnormal heat is being generated in transfer switch connection. See red arrows in PH#1 and TH#1. Loose and/or corroded contact area. Clean, inspect and re-secure serviceable components. TH # 1 > TEMPERATURE ABOVE AOT 173 C / 311 F

PROJECT: 05220616 CUST REP: SCAN REP: Ash Trey Dent DATE: 06/22/2016 LOCATION: Main Electric Room Box Labeled: ATS-1 Molded Case Breaker Labeled: Normal < PH # 2 ITEM: SOURCE: TEMP: Aø of Case Breaker (N1 Connection) Line side lead connection lug Temp. of connection and lug is: 84ºC / 183ºF Total Temp. - 34ºC / 93ºF AOT = 50ºC / 90ºF above AOT. < TH # 2 < TH # 2 COMMENTS Abnormal heat is being generated in case breaker connection. See orange arrows in PH#2 and TH#2. Loose and/or corroded contact area. Clean, inspect and re-secure serviceable components. TEMPERATURE ABOVE AOT 50 C / 90 F

AREA/EQUIPMENT LIST Following is a list of the electrical equipment located at the Sysco Buckhead Beef, College Park, Georgia, facility and data relating to its operating condition at the time the scan was performed. NOTE: Items noted as visually inspected were not operational or show no visible load at the time of the inspection. No. Equipment Operating Visually Inspected PRODUCTION CUT SHOP Fault # 1 Trim Line Conveyer Control Cabinet (tenderloin) X 2 Trim Line Conveyer Control Cabinet (top butt) X 3 Spray Intervention (tenderloin) X 4 Slicer Control Cabinet (top butt) X 5 Panel A18 Sorta Wave (top butt) X 6 Slicer Control Cabinet (tenderloin) X 7 Panel A18 Sorta Wave (tenderloin) X PACKING ROOM 8 #6 Multi-Vac Control Cabinet X 9 #5 Multi-Vac Control Cabinet X 10 #4 Multi-Vac Control Cabinet X 11 #3 Multi-Vac Control Cabinet X 12 #2 Multi-Vac Control Cabinet X 13 #1 Multi-Vac Control Cabinet X FINISHING ROOM 14 Conveyer Control Cabinet X CHARGER ROOM 15 Battery Chargers X MAINTENANCE 16 Air Compressor Control Cabinet X 17 Air Compressor Fuse Disconnect X

No. Equipment Operating Visually Inspected MAINTENANCE MEZZANINE Fault # MCC 18 Glycol Chiller X 19 RTU-5 X 20 RTU-1 X 21 RTU-4 X 22 Spare X 23 Exhaust Fan 15 X 24 MAU-1 X 25 MAU-2 X 26 Spare X 27 RTU-6 X 28 Exhaust Fan 3 X 29 Exhaust Fan 4 X 30 Exhaust Fan 5 X 31 MB 480/277 Volt Distribution Panel X 32 M2H 480/277 Volt Distribution Panel X 33 TM2L Eaton Transformer 3ø 75KVA X 34 M2L 208/120 Volt Distribution Panel X 35 TM1LA Disconnect X 36 T-M1LA Eaton Transformer 3ø 75KVA X 37 M1LA 208/120 Volt Distribution Panel X 38 T-M1L Disconnect X 39 T-M1L Eaton Transformer 3ø 112.5KVA X 40 M1L 208/120 Volt Distribution Panel X 41 M1LB 208/120 Volt Distribution Panel (Right) X 42 MC 480/277 Volt Distribution Panel X 43 L1 480/277 Volt Distribution Panel X 44 L2 480/277 Volt Distribution Panel X

No. Equipment Operating Visually Inspected 45 MILB 208/120 Volt Distribution Panel X 46 TD Disconnect X 47 T-D Eaton Transformer 3ø 225KVA X 48 D 240 Volt Distribution Panel X KITCHEN 49 Exhaust Fan Control Cabinet X 50 Exhaust Hood Control Cabinet X OUTSIDE 51 Pad Mounted Transformer (fins only) X MAIN ELECTRICAL ROOM 52 MA 480/277 Volt Distribution Panel X 53 MC Fuse Disconnect X 54 MA Fuse Disconnect X 55 M1H Fuse Disconnect X 56 Transfer Switch ATS-2 X 1 57 Transfer Switch ATS-1 L1 X 2 58 Transfer Switch ATS-3 MD X 59 Switchgear 3 Sections X 60 T-P Eaton Transformer 3ø 150KVA X 61 P1 208/120 Volt Distribution Panel X 62 P2 208/120 Volt Distribution Panel X 63 P4 208/120 Volt Distribution Panel X 64 P3 208/120 Volt Distribution Panel 65 P5 208/120 Volt Distribution Panel X 66 MD 480/277 Volt Distribution Panel X 67 M1H 480/277 Volt Distribution Panel X DRY STORAGE 68 ZLV-01 208/120 Volt Distribution Panel X 69 Unlabeled Disconnect X 70 Eaton Transformer 3ø 75KVA X Fault #