Vacuum / Release Unit

Similar documents
Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Series ZFC. Air Suction Filter. In-line Type with One-touch Fittings

CAT.ES60-17 A. Compact Electro-pneumatic Regulator. Series ITV0000. Compact and lightweight electro-pneumatic regulator

Series IRV1000/2000/3000

Related Products: Auto Drain Valve. Model/Specifications. Model

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Clean Air Filter Built-in Hollow Fiber Element

THE WORLD COMPETITIVENESS SCOREBOARD 2011

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Max Sort Sortation Option - Letters

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Operation Manual Air Saver Unit ASV5000 Series

Industrial Filter. FGD series

Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

AREA TOTALS OECD Composite Leading Indicators. OECD Total. OECD + Major 6 Non Member Countries. Major Five Asia. Major Seven.

Relays/Valves. Lock-Up Valve. Series IL201/211/220 EMC.IL A-UK

Air operated valve. VGA342R Series

Pilot Check Valve: Metal Body Type

Filter-Regulator-Lubricator

TERMINAL BLOCK SUMMARY

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

5 Port Solenoid Valve

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Low torque Metal seal type Rotary joint

IR1000-A IR1010-A IR1020-A

Series AMJ. Drain Separator for Vacuum

Update of trade weights data underlying the EERs and HCIs

Moisture Control Tube

INSTALLATION & MAINTENANCE INSTRUCTIONS

5 Port Air Operated Valve

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

reduces flow setting time and setting errors!

Series ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU

Vacuum Pad with Ejector. Series ZHP

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Direct Operated Precision Regulator Modular Style. Standard Specifications

2018 Hearthstone Wild Open. Official Competition Rules

Multistage Ejector Series ZL

Multistage Ejector Series ZL

HydroCOM: High energy savings and excellent controllability

Remote Control VP04 Pneumatic Proportional Remote Control Valve zrc02. Catalogue HY /UK December, 2004

NITROGEN CHARGING KIT type PC 11.1 E 04-11

NITROGEN CHARGING KIT type PC 11.1 E 01-12

Auxiliary Valve PRS6 Pressure Reducing Valve. Catalogue HY /UK June 2003

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Low Friction Cylinders

q w e r t Description Rc NPT 1/8 1/4 3/8 1/2

ASB Accumulator Safety Blocks

Firearms & parts firearms & parts firearms & parts rocket launcher components

Plant Air Energy Saving

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Pressure Sensor PSE53#

IRV Series. Vacuum Regulator. 240l/min (ANR) 140 l/min (ANR) Single Sided Connections Series. New and Improved. Series IRV10/20

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Filter-Regulator-Lubricator

VACUUM REGULATORS CONTENTS

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Medium-sized vessels water connection. White paper

Marsh & McLennan Companies Entities Covered by the BCRs

I. World trade in Overview

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

Parallel Seal Type Slit Valve

(8N) % ) 20% (1.1 (5 N))

The 11th Korea Prime Minister Cup International Amateur Baduk Championship

Welcome to KNX Scientific Conference 2012 Las Palmas Gran Canaria Watch how international KNX has become!

Marsh & McLennan Companies Entities Covered by the BCRs

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

Precision Regulator. Series Model Regulating pressure range Port size Page

KINGDOM OF CAMBODIA NATION RELIGION KING 3

INTERNATIONAL SKATING UNION

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

Manual Actuated Boiler Blowdown Valves

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Stockholm s tourism industry. November 2016

Invitation to. The 36th World Amateur Go Championship in Bangkok. Outline

CMMI Maturity Profile Report. 30 June 2017

Desalination From theory to practice People, Papers, Publications. Miriam Balaban EDS Secretary General

Production, trade and supply of natural gas Terajoules

Stockholm s tourism industry. December 2016

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

SCH-27. Diaphragm Pressure Switch. Setting range: mbar to bar. Temperature: max C. Material: stainless steel

New rules, new opportunities: a potential for growth

Precision Regulator IR3120

Table I. NET CALORIFIC VALUES OF ENERGY PRODUCTS GJ/ton

I N T E R N A T I O N A L S K A T I N G U N I O N

Portuguese, English, and. Bulgarian, English, French, or

European Values Study & World Values Study - Participating Countries ( )

PVC Quick Drain Valve

German Machine Tool Industry - Key Figures

Transcription:

Vacuum / Release Unit Response speed 13 msec (at 500 mm )/18.5 msec (at 1000 mm ) Distance from the unit to the work area Smooth detachment of a work piece without over-blow The work piece will not be blown away when the air is released. No need to adjust the timing when switching between vacuum and positive pressure. (single signal control) No need to design a restrictor circuit for release air. ON Adaptable to 0603 chip OFF Atmospheric pressure The work piece will not be blown away. The work piece is detached as smoothly as possible by the subsonic release air. Even small electronic components such as a 0603 (0.6 mm x 0.3 mm) chip will not be blown away. Ordinary circuit Over-blow A small and light work piece can be blown away. Vacuum pressure ( 80 kpa) 13 msec (Constant) 60 msec or more (Vary depending on a condition.) <Condition> Distance from the unit to the work area at 500 mm Piping I.O.: ø2.5 Positive pressure (Release air): P Vacuum pressure (Suction air): V 10-VQ110 (For charging release air) VQD1151W (For switching) Integral tank Connection port (M5 or Rc 1/8) Work piece: A (Pad or Nozzle) Positive pressure: P (Release air) air) Vacuum pressure: V (Suction air) air) Work piece: A (Pad (Pad or or Nozzle) Nozzle) Series VQD1000-V CAT.ES11-93A

Vacuum / Release Unit Series VQD1000-V Positive pressure (Release air): P Vacuum pressure (Suction air): V Positive pressure: P (Release air) air) Vacuum pressure: V (Suction air) air) Work piece: A (Pad or Nozzle) Nozzle) Suction filter can be cleaned. If you energize the VQD1151W, you can clean the suction filter using positive-pressure air blowing. Suction filter (installed near a work) Recommended: FGZG220A-B40 (Filtration rating 40 µm) Charging release air Charging release air during absorption of a work piece. FGZG220A-B40 / Internal volume: 0.21 cm 3 M5 ø12.5 17.3 M5 Connection port Connection port Suction Work piece Work piece: A (Pad or Nozzle) When cleaning (air-blowing), use a pressure of 1.5 MPa or greater, repeating the process several times but for less than 2 seconds at a time. When the distance between work pieces is fluctuated. Compatible with an atmospheric release pressure circuit Possible to make it an atmospheric release type by installing a check valve on the connecting port and by setting the release air pressure (P) lower. (When the release air is running low, the pressure inside the tank changes to vacuum from the positive pressure. In this case, the pressure is rapidly released to the atmosphere due to the check valve.) Atmospheric pressure suction port Recommended check valve AKH04B-M5 When the release pressure is running low. Additionally a tank can be installed. Possible to add a tank for charging release air in accordance with the distance (volume) between the unit from the work piece. Added tank (using piping materials) [Example of tank addition] Tube cap KQ2C series Tube P One-touch fitting KQ2H series V Made to Order Please contact SMC for details. Vacuum shut type (normally closed) when de-energized Features 1

Working principle When de-energized Vacuum absorption De-energizing 2 solenoid valves simultaneously Charging release air during absorption of a work piece P2: Release air P1: Suction air PAT. PEND. V1: Total volume V2: Charging release air Connection port Work piece Suction When energized Release Shut Energizing 2 solenoid valves simultaneously Release air is discharged and the pressure required for detaching / releasing a work piece turns to atmospheric pressure, resulting in smooth detachment. Release air Suction air Release air Suction air P: Atmospheric pressure Discharging release air Work piece Release Atmospheric pressure Work piece Smooth detachment <Relationship between pressure and a release air tank> (P + 0.1) x (V1 + V2) (P1 + 0.1) x V1 P2 = 0.1 V2 P1: Suction vacuum pressure / Negative pressure (MPa) P2: Release pressure / Positive pressure (MPa) P: Detaching (Release) pressure (MPa) 0 MPa (atmospheric pressure) is normal. P2: Release Air Guideline Distance between the unit and the work area (mm) V1: Total volume from the unit to the work area (cm 3 ) P2: Release pressure (MPa) <Conditions> VQD1000-V VQD1000-VL 300 1.68 0.19 Suction vacuum pressure (P1): 90 kpa ( 0.090 MPa) Piping tube size: ø4 (I.D. ø2.5) Suction filter: When mounting FGZG220A-B040 (internal volume: 0.21 cm 3 ) V1: Total volume from a unit to a work piece (cm 3 ) V2: Volume of a release air tank (cm 3 ) VQD1000-V type: 0.8 cm 3 VQD1000-VL type: 3.2 cm 3 500 2.66 0.30 0.07 1000 5.12 0.58 0.14 2000 10.02 0.28 [How to Adjust] 1. Adjust P2 release pressure, using a regulator, in accordance with V1 volume. We recommend that you use our precision type, IR series. 2. When V1 volume differs in the same manifold, equalize it by adjusting the length or internal diameter of the piping. Even when the piping length is extended a good response is ensured. Front matter 1

Vacuum / Release Unit Series VQD1000-V How to Order Vacuum / Release Unit VQD1000 V 05 5 Nil L Volume of release air tank: V2 0.8 cm 3 Guideline: 1 m or shorter distanced from a work piece 3.2 cm 3 Guideline: 1 m or longer distanced from a work piece Note) Calculate according to the related formula between pressure and a release air tank on front matter 1, and select either one. Electrical entry Nil: L plug connector Standard type 01 02 10 Stations 1 unit (1 station) 2 units (2 stations) 10 units (10 stations) M: M plug connector Performances in valve installation / de-installation and handling of a connector is less ensured. Voltage 5 24 VDC 6 12 VDC 10-VQ110- -X46 (For charging release air) VQD1151W- (For switching) JIS Symbol Positive pressure (Release air) P Vacuum pressure (Suction air) V 10-VQ110- -X46 (For charging release air) VQD1151W- (For switching) Positive pressure: P (Release air) Vacuum pressure: V (Suction air) Work piece: A (Pad or Nozzle) Integral tank Connection port (M5 or Rc 1/8) A (Work piece) 1

Vacuum / Release Unit Series VQD1000-V Specifications Valve specifications Electric specifications Valve construction Fluid Operating Suction (negative pressure) pressure range Release (positive pressure) Response Suction (OFF) time Release (ON) Suction flow rate/sonic conductance Manual override Shock/Vibration resistance Mounting postion Enclosure Coil rated voltage Allowable rated voltage Coil insulation type Power VQD1151W (for switching) consumption 10-VQ110 (for release supply) Electrical entry Direct operated poppet valve Air, Inert gas/low ozone resistant product 0 to 100 kpa 0 to 0.7 MPa 2 ± 1 msec 4 ± 1 msec 16 l/min/0.27 dm 3 /(s bar) Non-locking push type 150/30 m/s 2 Unrestricted Dusttight 24 VDC, 12 VDC ±10% of rated voltage Class B or equivalent 3.2 W energy saving type (Inrush: 3.2 W, Holding: 2.4 W) 1 W L/M plug connector (with light/surge voltage suppressor) Replacement Parts w q q Solenoid valve for switching VQD1151W 5 5 6 Voltage 24 VDC 12 VDC L Electrical entry L L plug connector M M plug connector P V w Solenoid valve for charging release air 10-VQ110 5 6 Voltage 24 VDC 12 VDC 5 L X46 Electrical entry L L plug connector M M plug connector Note) Product with specification on pressurizing R port. If a standard product is used, external leakage may occur. 2

Series VQD1000-V Replacement Parts 11.5 (13.5) 8.3 (10.3) P=11 P=11 n x M5 (Rc 1/8) (Connection port) 40.7 (45.7) 2 x M5 (Release supply port) 21.4 5 (7) 25.7 (L type) 24.7 (M type) D side 3 L1 L2 3 U side M plug connector 4 x ø3.5 (Mounting hole) 82.7 (M type) 77.2 (L type) 66 49 P 58 25 L plug connector (Standard type) V P V 29.5 2 x M5 (Vacuum supply port) 10.5 (15.5) 41.1 (46.1) Stations 1 2 3 n 22.5 (27.5) 15 (20) 7.5 (12.5) A A 11.5 (13.5) 14.5 (16.5) P = 11 n x M5 (Output port) L: Dimensions (VQD1000-V- / Standard type: Tank volume 0.8 cm 3 ) L n 1 2 3 4 5 6 7 8 9 10 L1 L2 23 17 34 28 45 39 56 50 67 61 78 72 89 83 100 94 111 105 122 116 Formula: L1 = 11n + 12, L2 = 11n + 6 (Max. 10 stations) L: Dimensions (VQD1000-VL- / Tank volume 3.2 cm 3 ) L n 1 2 3 4 5 6 7 8 9 10 L1 L2 25 19 36 30 47 41 58 52 69 63 80 74 91 85 102 96 113 107 124 118 Formula: L1 = 11n + 14, L2 = 11n + 8 (Max. 10 stations) 3 The dimensions shown in brackets indicate the VQD1000-VL- / tank volume 3.2 cm 3.

Series VQD1000-V Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO 4414 Note 1), JIS B 8370 Note 2) and other safety practices. Explanation of the labels Labels Danger Warning Explanation of the labels In extreme conditions, there is a possible result of serious injury or loss of life. Operator error could result in serious injury or loss of life. Caution Operator error could result in injury Note 3) or equipment damage. Note 4) Note 1) ISO 4414: Pneumatic fluid power General rules relating to systems Note 2) JIS B 8370: General Rules for Pneumatic Equipment Note 3) Injury indicates light wounds, burns and electrical shocks that do not require hospitalization or hospital visits for long-term medical treatment. Note 4) Equipment damage refers to extensive damage to the equipment and surrounding devices. Selection/Handling/Applications 1. The compatibility of the pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or post analysis and/or tests to meet the specific requirements. The expected performance and safety assurance are the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system. 2. Only trained personnel should operate pneumatic machinery and equipment. Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of the systems using pneumatic equipment should be performed by trained and experienced operators. (Understanding JIS B 8370 General Rules for Pneumatic Equipment, and other safety rules are included.) 3. Do not service the machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of the machinery/equipment should only be performed once measures to prevent falling or runaway of the driven objects have been confirmed. 2. If the equipment must be removed, confirm the safety process as mentioned above. Turn off the supply pressure for the equipment and exhaust all residual compressed air in the system, and release all the energy (liquid pressure, spring, condenser, gravity). 3. Before the machinery/equipment is restarted, take measures to prevent quick extension of a cylinder piston rod, etc. 4. If the equipment will be used in the following conditions or environment, please contact SMC first and be sure to take all necessary safety precautions. 1. Conditions and environments beyond the given specifications, or if product is used outdoors. 2. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, requiring special safety analysis. 4. If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for the prevention of a breakdown. And, examine the devices periodically if they function normally or not. Exemption from liability 1. SMC is exempted from liability for any damages caused by earthquakes, fire for which SMC is not responsible for, actions by a third person, accidents, customer error with or without intention, product misuse, and any other damages caused by abnormal operating conditions. 2. SMC is exempted from liability for any accompanied damages, such as profit loss and discontinuation of business operation, caused by the operation or incompetency to operate our products. 3. SMC is exempted from liability for any damages caused by operations, which the catalogs and instruction manuals have not introduced, and operations outside of the specification range. 4. SMC is exempted from liability for any damages caused by malfunctions of our products when combined with other devices or software in which SMC is not involved in. Back page 1

Series VQD1000-V Specific Product Precautions Be sure to read this before handling. For Safety Instructions, refer to the back of page 1. For Common Precautions, refer to Precautions for Handling Pneumatic Devices (M-03-E3A). Manual Override Operation Warning Connected actuator is started by manual operation. Use the manual override after confirming that there is no danger. Non-locking push type (Tool required) ø3 push part VQD1151W- (For switching) Caution VQD1151W- (For switching) Timer circuit 10-VQ110- -X46 (For charging release air) For the VQD1151W specifications (energy saving type), power consumption at holding is reduced with the above circuit. Refer to electrical power waveform as shown below. <Energy saving type s electrical power waveform> (Rated voltage: at 24 VDC) 24 V 0 V Varistor Applied voltage In order to turn it ON, push down the manual override button in the direction the arrow ( ) indicates until it stops (approx. 0.5 mm), and release it to turn it OFF. Wiring Specifications Coil LED (+) i1 i2 ( ) i1: Inrush current i2: Holding current Lead wire Red Black Connector C A Continuous Energization Warning Coil temperature may get high due to ambient temperature or energizing duration. Do not touch the valve by hand directly. When there is such a dangerous case to be touched by hand directly, install a protective cover. Caution When simultaneously energizing 3 stations or more, make sure to place an energized and non-energized valve alternatively. However, if this is not possible and 3 stations or more need to be energized simultaneously, the energizing time should be less than 30 minutes to achieve an energized status not exceeding 50%. Caution After confirming the gasket is correctly placed under the valve, securely tighten the bolts with the proper torque shown in the table below. Proper tightening torque (N m) 0.18 to 0.25 Caution Valve Mounting How to Use Plug Connector Attaching and detaching connectors To attach a connector, hold the lever and connector unit between your fingers and insert straight onto the pins of the solenoid valve so that the lever s pawl is pushed into the groove and locks. To detach a connector, remove the pawl from the groove by pushing the lever downward with your thumb, and pull the connector straight out. Note) Gently pull the lead wire, otherwise it may cause contact failure or disconnection. Cover Groove Pin Lever Connector 3.2 W 2.4 W Energy saving type Lever 0 W 10 to 20 ms 10-VQ110- -X46 (For charging release air) Coil (+) ( ) ( ) (+) Lead wire Red Black Connector C A Caution Connector When Piping to a Product When piping to a product, check the supply port, etc. Also, when tightening the piping tube, clamp the base unit to avoid any undue force from being applied to the valve. If a force of 120 N or more is applied to the coil especially, the connecting pin may be deformed, resulting in malfunction. Back page 2

SMC'S GLOBAL MANUFACTURING, DISTRIBUTION AND SERVICE NETWORK EUROPE AUSTRIA SMC Pneumatik GmbH BELGIUM SMC Pneumatics N.V./S.A. BULGARIA SMC Industrial Automation Bulgaria EOOD CROATIA SMC Industrijska automatika d.o.o. CZECH REPUBLIC NORWAY SMC Pneumatics Norway A/S POLAND SMC Industrial Automation Polska Sp.z.o.o. ROMANIA SMC Romania s.r.l. RUSSIA SMC Pneumatik LLC. SLOVAKIA SMC Priemyselná automatizáciá, s.r.o. SINGAPORE SMC Pneumatics (S.E.A.) Pte. Ltd. SOUTH KOREA SMC Pneumatics Korea Co., Ltd. TAIWAN SMC Pneumatics (Taiwan) Co., Ltd. THAILAND SMC Thailand Ltd. NORTH AMERICA SMC Industrial Automation CZ s.r.o. SLOVENIA CANADA DENMARK SMC INDUSTRIJSKA AVTOMATIKA d.o.o. SMC Pneumatics (Canada) Ltd. SMC Pneumatik A/S SPAIN/PORTUGAL MEXICO ESTONIA SMC España, S.A. SMC Corporation (Mexico) S.A. de C.V. SMC Pneumatics Estonia OÜ SWEDEN USA FINLAND SMC Pneumatics Sweden AB SMC Corporation of America SMC Pneumatics Finland OY FRANCE SMC Pneumatique SA GERMANY SWITZERLAND SMC Pneumatik AG. UK SMC Pneumatics (U.K.) Ltd. SOUTH AMERICA ARGENTINA SMC Argentina S.A. SMC Pneumatik GmbH BOLIVIA GREECE ASIA SMC Pneumatics Bolivia S.R.L. SMC Hellas EPE HUNGARY SMC Hungary Ipari Automatizálási Kft. IRELAND SMC Pneumatics (Ireland) Ltd. ITALY SMC Italia S.p.A. LATVIA SMC Pnuematics Latvia SIA LITHUANIA SMC Pneumatics Lietuva, UAB NETHERLANDS SMC Pneumatics BV. CHINA SMC (China) Co., Ltd. HONG KONG SMC Pneumatics (Hong Kong) Ltd. INDIA SMC Pneumatics (India) Pvt. Ltd. INDONESIA PT. SMC Pneumatics Indonesia MALAYSIA SMC Pneumatics (S.E.A.) Sdn. Bhd. PHILIPPINES SHOKETSU-SMC Corporation BRAZIL SMC Pneumaticos Do Brazil Ltda. CHILE SMC Pneumatics (Chile) S.A. VENEZUELA SMC Neumatica Venezuela S.A. OCEANIA AUSTRALIA SMC Pneumatics (Australia) Pty. Ltd. NEW ZEALAND SMC Pneumatics (N.Z.) Ltd. Safety Instructions Be sure to read Precautions for Handling Pneumatic Devices (M-03-E3A) before using. Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362 URL http://www.smcworld.com 2006 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. D-DN 1st printing KV printing KV 120DN Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.