Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry

Similar documents
WORKHOLDING APPLICATION BOOKLET

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Courses of Instruction: Controlling and Monitoring of Pipelines

AUTOMATIC HOSE TEST UNIT, TYPE SPU

KRONES filling systems for beer Filling of glass containers and cans

Sizing Pulsation Dampeners Is Critical to Effectiveness

M-System s I/P and P/I Transducers

Air Amplifiers & SYSTEMS

Compiled by: B Beard. Approved by: SH Carstens. Description of requirements and procedures for compact provers to be used as verification standards.

Max. working pressure 3650 bar / 52,200 psi Max. flow up to 50 liters / minute Fully made of stainless steel I N N OVATO R S T H E O U R

AIR DRIVEN. Gas Boosters & SYSTEMS. Accepting VISA, MasterCard and American Express

HAVER & BOECKER. Information HAVER ROTOSEAL PACKER

Drilling Efficiency Utilizing Coriolis Flow Technology

Air Operated Hydraulic Pumping Systems to 50,000 psi

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL OTHER FLUID POWER VALVES. This work covers part of outcome 2 of the Edexcel standard module:

WATER HYDRAULIC HIGH SPEED SOLENOID VALVE AND ITS APPLICATION

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

HIGH-PRESSURE HIGH-FLOW PUMP UNITS TYPE BMS

IBEDA GAS MIXERS HIGHEST PRECISION FOR YOUR WELDING AND CUTTING PROCESSES

Inflatable Packer Single & Double. Single & Double Packer Dimension. Wireline Packer. Water Testing Packer (WTP) Packer

Lab 3 Introduction to Quantitative Analysis: Pumps and Measurements of Flow

Experimental Investigation on Transient Response of Two Stage Pressure Relief Valve

A centrifugal pump consists of an impeller attached to and rotating with the shaft and a casing that encloses the impeller.

Characterizers for control loops

MODEL HICV-130Ti7-331N. Lot NAGOYA JAPAN PAT.

Cover Page for Lab Report Group Portion. Head Losses in Pipes

LECTURE 20 FLOW CONTROL VAVLES SELF EVALUATION QUESTIONS AND ANSWERS

AIR DRIVEN LIQUID PUMPS AIR DRIVEN AIR AMPLIFIERS AIR DRIVEN GAS BOOSTERS HIGH PRESSURE VALVES, FITTINGS AND TUBING TEST AND CALIBRATION EQUIPMENT

Effect of Fluid Density and Temperature on Discharge Coefficient of Ogee Spillways Using Physical Models

Pressure on Demand. Air Pressure Amplifiers

Experiment 18 Properties of Gases

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Priority (Swing) Motors Data and Specifications

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS

EMERGENCY CORE COOLING SYSTEM SIMPLIFICATION

Experimental Verification of Integrated Pressure Suppression Systems in Fusion Reactors at In-Vessel Loss-of -Coolant Events

OIL SUPPLY SYSTEMS ABOVE 45kW OUTPUT 4.1 Oil Supply

Multiple Pressure Booster Systems With Variable Speed Controller Type BL

AN ANALYSIS ON HIGH PRESSURE DYNAMIC CALIBRATORS USED IN THE DEFENSE AREAS

Plant, components and devices for very high and high pressures (7000 bar and over)

The Future of Hydraulic Control in Water-Systems

EPP pneumatic pumping stations PRODUCT CATALOG

HumiSys HF High Flow RH Generator

Precision level sensing with low-pressure module MS

Test Report # Rev 0. Adiabatic Compression With Constant Bleed Valve

Experiment Instructions. Circulating Pumps Training Panel

Max operation pressure 6kg/cm 2. Boost pressure rate Air pressure supply 5kg/cm Hydraulic fluid expelled l/min

Introduction to Pumps

Proportional Valve Group PVG 32 minibooster

Study of Properties of a Dispersant Used for Extracting Oil with High Gas-Oil Ratio

Laboratory Mortar Mixer (Testing)

Unit 24: Applications of Pneumatics and Hydraulics

VALVES HIDROMATIC VALVE.

Reclaim Basic Set Up

HydroCOM: High energy savings and excellent controllability

HANDBOOK. Squeeze Off Unit SOU 400. Please refer any queries to:

1020 Industrial Drive, Orlinda, TN fax

Cascade control. Cascade control. 2. Cascade control - details

WHITEPAPER. Integrated process monitoring of dosing pressures

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

Flow divider designs MTL

Influencing Factors Study of the Variable Speed Scroll Compressor with EVI Technology

Gerald D. Anderson. Education Technical Specialist

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL ACCUMULATORS. This work covers part of outcome 2 of the Edexcel standard module:

deltaflowc deltaflowc Venturi or Probe

2/2-Way Solenoid Control Valve

WATER HYDRAULIC SYSTEM FOR HIGH SPEED CYLINDER DRIVE

Product Information. Three in One: Gas Meter Tariff Device Volume Corrector. Ultrasonic Gas Meter ECOSONIC X12

Water Flow Regulators. The Leading Water Flow Regulator Worldwide. Essential Equipment For every injection and blow molding machine

The Nitrogen Threat. The simple answer to a serious problem. 1. Why nitrogen is a risky threat to our reactors? 2. Current strategies to deal with it.

Unit 24: Applications of Pneumatics and Hydraulics

hydro-pac, inc. Low-Pressure Gas Compressors 1500 to 6000 PSI

The Estimation Of Compressor Performance Using A Theoretical Analysis Of The Gas Flow Through the Muffler Combined With Valve Motion

OWNER S TECHNICAL MANUAL

Processing instructions V 3.6 REFRAJET Nanobond

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Design. Pompetravaini-NSB API SB Liquid Ring Compressor for Gas Processing. Working Principle

Lecture 26 HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

LP Separator Level Control by Variable Speed and Multi Stage Brine Reinjection Pumps at Kawerau and Nga Awa Purua Geothermal Projects, New Zealand

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

POLISH MARITIME RESEARCH 4(80) 2013 Vol 20; pp /pomr

Constant and Particle Free Point-of-Use Water Pressure

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

Plant Air Energy Saving

Application Note AN-107

Control & Maintenance. INT69 Diagnose INT69 TM Diagnose. Protect the heart of your system

Application and Sizing

Coriolis Mass Flow Meter

Cover Page for Lab Report Group Portion. Pump Performance

CSO/STORMWATER MANAGEMENT. HYDROVEX HHV-E Vortex Driven Regulator

TEK-SUB 4800B. Submersible Level Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys LEVEL

M-06 Nitrogen Generator (Nitrogen Making Machine)

United Kingdom of Great Britain and Northern Ireland

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

Optimization of rotor profiles for energy efficiency by using chamber-based screw model

The benefits of system solutions for valve users

Leak Checking Large Vacuum Chambers

Model 1800 PFM Series Regulator For Constant Outlet Pressure Precise Fixed Factor Measurement From 0.5 to 30 PSIG

Verification and validation of computer codes Exercise

STANDARD HIGH PRESSURE COMPRESSORS COMPACT PACKAGE FOR DEMANDING APPLICATIONS

Transcription:

Developments on Flow Rate And High Pressure Stability of Peroxide Dosing Pumps For The Chemical Industry Franz Trieb, Reinhard Karl, Rene Moderer Bohler Hochdrucktechnik GmbH Kapfenberg, Austria www.bhdt.at Performance and reliability of peroxide dosing pumps are essential for every low density polyethylene (LDPE) plant. High stability of flow rate and high pressure is the most important feature for this pumps. The paper compares the results of hydraulic pressure inside the actuating system as well as flow rate and high pressure level on the discharge connection of the pump. Recording was done with a flow meter and a high pressure transducer, both suitable for a maximum pressure of 400 MPa. Direct measurement inside the high pressure cylinder and the influence of a pressure accumulator in the high pressure injection line at low capacity and full load condition round out this work. 1. Introduction A high pressure process is used for the generation of Low Density Polyethylene (LDPE), which takes mainly place in a tubular reactor at about 300 MPa and 300 Celsius. Such kinds of plants are built with an annual output of up to 400,000 tons and are in operation permanently which requires a high reliability. The core piece of an LDPE plant is the tubular reactor, which has a total length of up to 3,000 m. This unit is used for the polymerization process which converts ethylene gas with a monomer structure into polyethylene with a chain structure. In order to set up the polymerization process in an economical manner, peroxides are fed to the hot compressed ethylene gas in different reactor sections. As the quantity of the peroxide which initiates an exothermic reaction is a significant process parameter, a precise dosing is required at an injection pressure of approximately 300 MPa. This task is taken over by peroxide dosing pumps which deliver up to 100 l/h of peroxide to the various injection points into the reactor and thus have a decisive influence on the polymerization process. 2. Basic Principle of Dosing Pumps Dosing pumps operate according to the pressure intensifier principle. High pressure intensifiers are double acting as a rule. Sometimes the pumps are equipped with a standby intensifier to ensure high availability. Pressure intensifiers are oil hydraulically driven by means of a servo hydraulic rate control system, which ensures a constant volume of oil flow independent of the pressure, and thus peroxide is also delivered by the transmission ratio. Moreover, this control concept enables the manipulation of the acceleration phase of the plunger after the change of direction. The behavior of the pump can be controlled electronically during the compression phase.

To ensure a high dosing accuracy, a continuous filling degree of the high pressure cylinder is essential. In order to ensure this happen, a booster pump is fitted upstream of the pressure intensifier on the suction side. Figure 1 shows the system diagram of a peroxide dosing pump with stand-by intensifier and high pressure accumulato. Figure 1: System diagram of pump with stand-by intensifier and accumulator Figure 2: Top view of peroxide dosing pump with stand-by intensifier

For a high plant availability, high pressure components are fitted redundantly and have been designed to be maintenance friendly. After automatic switch over, the integrated block-and-bleed system can be activated, by which the pressure intensifier to be maintained is emptied and locked-off from the high pressure system. By this means, high pressure components, such as seals and check valves, can be maintained easily even if the other intensifier is in operation. The peroxide dosing pump is directly linked to the tubular reactor via a high pressure tubing sytem. The peroxide is injected via special injection lenses located on three or more different places along the reactor. 3. Parameters And Operating Conditions To analyze the dosing pump and to carry out the optimization on this basis, the following examinations with parameters mentioned as follows were measured: Discharge pressure, flow rate at the discharge outlet and hydraulic oil pressure. For different variations, the program for the servo valve was adapted. The behavior of the measured parameters were recorded for different boost signals, inside the high pressure cylinder and with an accumulator in the high pressure line. For investigation, a dosing pump with a maximum flow rate of 78 l/h (1,3 l/min) togther with a high pressure valve with different orifice diameters was used. 4. Measurement Equipment And Testing Points The examination was carried out by means of a DEWE-BOOK-16 measuring system. Figure 3 shows the measurement equipment at the outlet of the pump consisting of a flow meter and a high pressure transducer. The following sensors were used: Hydraulic oil pressure sensor, manufacturer Tecsis, (pressure range 0-25 MPa), high pressure sensor, manufacturer IMT Industrie-Meßtechnik, (pressure range: 0-400 MPa), Flow meter, manufacturer Küppers Elektromechanik (flow range: 0.3-1.5 and 0.5-4 l/min). Figure 3: Measurement equipment installed at the discharge side of the pump

5. Reciprocating Pump Control Reciprocating pumps suffer the problem that there is a delivery gap (pressure drop, flow reduction) at the reversal point of the plunger. To overcome this problem, a short and fast stroke can be selected. However, choosing a longer stroke to reduce load cycles, a larger plunger diameter to enhance the lifetime of the sealing system and a servo valve to compensate this factor, this delivery gap can be compensated and improved at the reactor inlet. The additional advantage of a servo valve controlled hydraulic system is the possibility to change the flow rate from the target to the maximum in the time span where the plunger changes direction and in the compression phase, which is about 10 % of the stroke at 300 MPa. To be able to investigate the best design of the control signal (boost signal) for the mentioned time gap, measuements of the oil hydraulic and outlet pressure as well as changes in output volume were made. The optimum signal was found in between three zones. In the following Figure 4 there are shown three cases with different boost signals. Also the typical behaviour of the hydraulic system can be seen. Figure 4: Influence of boost signal onr flow rate and high pressure In the first case, without a boost signal the system does not reach its potential as it does not use the whole power reserves of the hydraulic system. The second case with a signal of 110 ms gives an acceptable result for flow rate and high pressure. In the third case the boost signal is too dominating, which results in a fish tail profile of the flow rate which is not approved. The parameters of the boost signal could be programmed that way that it always acts in the right intensification of the shifting.

6. Measurements Inside High Pressure Cylinder To be able to make the pressure process in the high pressure cylinder measurable, the check valve was moved, as shown in Figure 5, so that the high pressure tube, in which the sensor is located, still belongs to the volume of the high pressure cylinder. Figure 5: Measurement equipment for high pressure cylinder The results are shown in Figure 6. The pressure profile of the hydraulic oil system is visible alternately, with a maximum value of about 10 MPa. Figure 6: Direct measurement ineide of high pressure cylinder

For clarity, only one high pressure side of the cylinders is shown with a maximum value of 300 MPa. The graph indicates the correlation between the low pressure and high pressure sides, so the high pressure profile can be calculated on the basis of the hydraulic oil behavior. 7. With And Without Accumulator In certain cases the installation of an accumulator within the high pressure line may inprove the pressure and flow characteristic of a peroxide dosing pump. Figure 7 shows the results of measurement with and without accumulator. Figure 7: Flow rate and pressure level with and without high pressure accumulator 8. Conclusion The measurements on flow rate and high pressure at the outlet were conducted to find the right parameters for the servo valve control. Also the dependency of the high pressure based on the hydraulic oil pressure was analyzed so system parameters can be modeled and optimized using available low pressure readings. Due to this benefit, the flow rate could be further smoothed using electronic control. Constant volume flow is a significant criterion. Using an electronic control for a servo valve controlled pump flow, a significant improvement can be verified. Another characteristic which was analyzed is the infulence of an accumulator in the high pressure line. 9. References Trieb, F., Karl R., Moderer R., 2006, High Pressure And Flow Rate Measurements on Peroxide Dosing Pumps Under Laboratory And Site Conditions, ASME-PVP 2006 Conference, Vancouver, Canada