Conductor Bushings Series 8174

Similar documents
E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

Junction Boxes Series 8118

Operating Instructions

Operating Instructions

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

4/2 way Pneumatic Solenoid Valve

Operating Instructions

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Pressure Measurement Single-range transmitters for general applications

Wide opening parallel grippers Series CGLN

IECEx Certificate of Conformity Annexe

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

Pressure transmitters EMP 2

Gas Pressure Regulator HON 300

Flow control valves Series RFU - RFO 2/

Manual Power relay SR853

COMPONENT SPECIFICATION M80-7XX SERIES CONNECTORS - THREE ROW

EXH. Specifications. Descriptions. Min. working pressure MPa

Supplementary instructions. Rod and cable components. for VEGAFLEX series 80. Document ID: 44968

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

SITRANS P measuring instruments for pressure

ATH-EXx. B Operating Instructions

February Cable glands For general industry and hazardous areas

Actuating elements for ComEx

Magnetic level switch type MR783 Instruction Manual

ComEx Actuating elements

INSTRUCTION MANUAL Pressure Relief Device LPT

Cost effective. Smooth. Reliable. LOG Internal Hole Gripper

EX-RECESSED CEILING LIGHT FITTINGS

Zelio Relays RSL Slim Interface Plug-In Relays

INSTRUCTION MANUAL NI-281WE

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

Pressure switch KP-E. Data sheet

CFSW. Hinges with built-in safety multiple switch

2-port seat valves PN25 with externally threaded connections

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Floodlight LED. Series Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Pressure Measurement Single-range transmitters for general applications

INSTRUCTION MANUAL COMPACT PRESS. SWITCHES SERIES PCS & PCA

Arran LED Floodlight Luminaire

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

VMR VMR-OTN VMR 6 bar

Expert Hydrostatic Level Transmitters

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

Electropneumatic Positioner Type 4763 Pneumatic Positioner Type 4765

Compact differential pressure switch Flameproof enclosure Ex d Models DE, DEC

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

EVRM-NC EVRM-6NC. delta-elektrogas.com. Safety solenoid valves for gas Manual reset - Normally closed DN10 DN300.

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

3.1. Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and according to EN : 2012

TECHNICAL INFORMATION

Position switches FP series

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell Fully Approved

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

CFSW. Hinges with built-in safety multiple switch

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Further technical information is available on

Ex-proof solenoid valves with spool position monitor on/off, with inductive proximity sensor - Multicertification ATEX, IECEx, EAC

IECEx Certificate of Conformity

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

IECEx Certificate of Conformity Annexe

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

Part I -Installation Tools Needed Screwdriver/Adjustable Wrench to 1-1/2 MOUNTING

Hand lever valves VHER

Bores: ø 10, 16, 20, 25, 32 mm

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

PN LINE. Technical remarks PN 11 PN 13 PN 14 PN 15 PN 17 PN 18 PN 20 PN 23 PN 25 PN 26 PN 27 PN 28 PN 29 PN 37 PN 38 PN 39 PN 40 PN 43 PN 10 8_9 10_12

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

High flow rate. Cost effective. Compliant. Gripper with GSW-B Shaft Interface and Compensation Unit

Pull-rope emergency stop switch Type HENEX and SEGEX OPERATING INSTRUCTIONS

differential pressure regulating valve - threaded

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

Pressure switch and Thermostat CAS

ATH-EXx. B Operating Instructions

Differential pressure switch MP 54, MP 55 and MP 55A

Certificate of Conformity

MJK Expert 700 / 800 / 900 / 7070 / 7060 MJK Expert 1400 / 3400

BUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Pressure maintenance valve SDV-P / SDV-P-E

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

safety Shut-Off Valve HON 721

Pressure controls for hydro carbons, zone II applications, Type KPE

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

Technical Data. Dimensions

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

CONNECTION > Super-rapid fittings Series 6000 GENERAL DATA. Fitting with connecting tube. Sprint

Part I - Installation

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Electro-Pneumatic Converter YT-940 SERIES

ARI-DP32 / DP33 / DP34 / DP34T / DP34Tri / DP35 Pneumatic actuator ARI-DP

Operating Instructions Rope Pull Switches RPS...

Transcription:

> Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The conductor bushings are used to provide the wire connection between flameproof enclosures and increased safety enclosures. The conductors are potted with high-quality, creepage-resistant PU-resin and are thus insulated from the enclosure wall. ATEX / IECEx Zone 1 2 2 21 22 For use in x x WebCode 21-6 EK III de 8174A Components for System Solutions /1

Selection Table Version Conductor size Conductor quantity Rated operational current at 4 C Rated operational voltage Thread size Thread tighting torque [Nm] Lead length Ex d / Ex e Order number Weight 8174/1 Threaded conductor bushing Note 3161E [mm 2 ] [pcs] [mm] kg. 4 7 A 7 V M16 x 1. 1 1/1 8174/11-413-11.112 6 7 A 7 V M24 x 1. 3 1/1 8174/12-613-11.16 12 7 A 7 V M33 x 1. 1/1 8174/13-1213-11.31 24 6 A 7 V M33 x 1. 1/1 8174/13-2413-11. 48 4. A 7 V M42 x 1. 1/1 8174/14-4813-11 1.9 6 4. A 7 V M48 x 1. 1/1 8174/1-613-11 1.33.7 4 9 A 7 V M16 x 1. 1 1/1 8174/11-41-11.136 6 9 A 7 V M24 x 1. 3 1/1 8174/12-61-11.21 8 9 A 7 V M24 x 1. 3 1/1 8174/12-81-11.23 12 9 A 7 V M33 x 1. 1/1 8174/13-121-11.398 24 7. A 7 V M33 x 1. 1/1 8174/13-241-11.699 48. A 7 V M42 x 1. 1/1 8174/14-481-11 1.383 6 6 A 7 V M48 x 1. 1/1 8174/1-61-11 1.713 1. 2 1 A 7 V M16 x 1. 1 1/1 8174/11-22-11.112 4 1 A 7 V M16 x 1. 1 1/1 8174/11-42-11.192 6 1 A 7 V M24 x 1. 3 1/1 8174/12-62-11.28 8 1 A 7 V M33 x 1. 1/1 8174/13-82-11.39 12 1 A 7 V M33 x 1. 1/1 8174/13-122-11.6 16 13 A 7 V M33 x 1. 1/1 8174/13-162-11.71 24 11. A 7 V M42 x 1. 1/1 8174/14-242-11 1.9 36 9. A 7 V M42 x 1. 1/1 8174/14-362-11 1.7 9 A 7 V M48 x 1. 1/1 8174/1-2-11 2.13 2. 4 2 A 7 V M24 x 1. 3 1/1 8174/12-43-11.3 12 19. A 7 V M33 x 1. 1/1 8174/13-123-11.8 24 1 A 7 V M42 x 1. 1/1 8174/14-243-11 1.69 36 14 A 7 V M48 x 1. 1/1 8174/1-363-11 2.493 4 3 2 A 7 V M24 x 1. 3 1/1 8174/12-34-11.321 6 2 A 7 V M33 x 1. 1/1 8174/13-64-11.627 18 22 A 7 V M42 x 1. 1/1 8174/14-184-11 1.791 6 3 33 A 7 V M24 x 1. 3 1/1 8174/12-3-11.4 6 33 A 7 V M33 x 1. 1/1 8174/13-6-11.88 12 33 A 7 V M42 x 1. 1/1 8174/14-12-11 1.7 1 3 4 A 7 V M33 x 1. 1/1 8174/13-36-11.73 4 4 A 7 V M42 x 1. 1/1 8174/14-46-11 1.39 6 4 A 7 V M42 x 1. 1/1 8174/14-66-11 1.491 16 3 61 A 7 V M42 x 1. 1/1 8174/14-37-11 1.2 4 61 A 7 V M42 x 1. 1/1 8174/14-47-11 1.91 6 61 A 7 V M42 x 1. 1/1 8174/14-67-11 2.391 2 3 83 A 7 V M42 x 1. 1/1 8174/14-38-11 1.8 4 83 A 7 V M48 x 1. 1/1 8174/1-48-11 2.261 3 3 13 A 7 V M42 x 1. 1/1 8174/14-39-11 2.283 4 13 A 7 V M48 x 1. 1/1 8174/1-49-11 3.17 1 132 A 1 V M33 x 1. 1/1 8174/13-11-11 1.3 3 132 A 1 V M48 x 1. 1/1 8174/1-31-11 3.813 7 1 16 A 1 V M33 x 1. 1/1 8174/13-111-11 1.8 4 3 7 V M33 x 1. 6 / 3 8174/13-34-2-69.426 1. 4 2. 3 7 V M33 x 1. 6 / 3 8174/13-34-3-69.47 Bushings with blue wires to connect intrinsically safe electric circuits are available upon request. /2 Components for System Solutions 21-6 EK III de

Selection Table Version Conductor size Conductor quantity Rated operational current at 4 C Rated operational voltage Bushing Diameter Lead length Ex d / Ex e Order number Weight 3164E 8174/2 Plain conductor bushing Note [mm 2 ] [pcs] [mm] kg. 12 7 A 7 V d 34 13/13 8174/23-1213-33.421. 24 6 A 7 V d 34 13/13 8174/23-2413-33.733. 48 4. A 7 V d 41 13/13 8174/24-4813-33 1.41. 6 4. A 7 V d 48 13/13 8174/2-613-33 1.77.7 4 9 A 7 V d 34 13/13 8174/23-41-33.244.7 12 9 A 7 V d 34 13/13 8174/23-121-33.1.7 24 7. A 7 V d 34 13/13 8174/23-241-33.92.7 48. A 7 V d 41 13/13 8174/24-481-33 1.77.7 6 6 A 7 V d 48 13/13 8174/2-61-33 2.243 1. 6 1 A 7 V d 34 13/13 8174/23-62-33.44 1. 12 1 A 7 V d 34 13/13 8174/23-122-33.733 1. 24 11. A 7 V d 41 13/13 8174/24-242-33 1.41 1. 9 A 7 V d 48 13/13 8174/2-2-33 2.81 2. 6 2 A 7 V d 34 13/13 8174/23-63-33.616 2. 12 19. A 7 V d 34 13/13 8174/23-123-33 1.1 2. 24 1 A 7 V d 41 13/13 8174/24-243-33 2.181 4 3 2 A 7 V d 34 13/13 8174/23-34-33.468 4 6 2 A 7 V d 34 13/13 8174/23-64-33.12 4 12 2 A 7 V d 41 13/13 8174/24-124-33 1.88 6 3 33 A 7 V d 34 13/13 8174/23-3-33.67 6 6 33 A 7 V d 34 13/13 8174/23-6-33 1.162 6 12 33 A 7 V d 41 13/13 8174/24-12-33 2.29 1 3 4 A 7 V d 34 13/13 8174/23-36-33.991 1 4 4 A 7 V d 41 13/13 8174/24-46-33 1.328 1 6 4 A 7 V d 41 13/13 8174/24-66-33 1.916 16 3 61 A 7 V d 41 13/13 8174/24-37-33.12 16 4 61 A 7 V d 41 13/13 8174/24-47-33 2.46 16 6 61 A 7 V d 48 13/13 8174/2-67-33 3.66 2 3 83 A 7 V d 41 13/13 8174/24-38-33 2.28 2 4 83 A 7 V d 48 13/13 8174/2-48-33 2.9 3 3 13 A 7 V d 48 13/13 8174/2-39-33 1.9 3 4 13 A 7 V d 48 13/13 8174/2-49-33 3.938 Bushings with blue wires to connect intrinsically safe electric circuits are available upon request. Explosion Protection Marking IECEx Ex d II, Ex d I Europe (ATEX) E II 2 G Ex d II E I M 2 Ex d I Certificates IECEx IECEx PTB 6.81U Europe (ATEX) PTB 1 ATEX 16 U Other certificates Canada (CSA), Belarus (Gospromnadzor) 21-6 EK III de Components for System Solutions /3

Technical Data Electrical data Rated operational voltage Rated operational current Ambient conditions Ambient temperature see diagrams of permissible current H7G-K HG-K S7G-K NSGAFöu (N)HX4GAF AWM UL 11 AWM UL 17 RADOX UL 3271 / CSA AWM I A/B RADOX 12 RADOX 1S FLR HV-K Mechanical data Material Threaded fitting Brass Sealing material PU-resin Bush Brass Conductor Size.... 7 mm 2 Series Number H7G-K HG-K S7G-K HV-K NSGAFöu (N)HX4GAF AWM UL 11 AWM UL 17 4/7 V 3/ V max. 7 V 3/ V 1 V 6/1 V max. 72, depends on size and nominal diameter AWM UL 11 AWM UL 17 RADOX UL 3271 / CSA AWM I A/B RADOX 12 RADOX 1S FLR hard-wired - 4... + 11 C - 4... + 11 C - 4... + 11 C - 4... + 8 C - 1... + 1 C - 1... + 1 C - 1... + 8 C - 2... + 12 C - 4... + 12 C - 4... + 1 C - 3... + 8 C AWG4... AWG2 AWG16... AWG2 flexible 6 V 3 V 6 V 6 V 6 V - 2... + 11 C - 2... + 11 C - 2... + 11 C - 2... + 8 C - 1... + 1 C - 2... + 12 C -... + 7 C Note on Assembly Connection of conductors on the Ex e, "increased safety" side of the bush comply with the relevant regulations. The installation of bushings must meet requirements of IEC/EN 679-1. A thread engagement of at least full threads is required (with a pitch of 1, mm, 8 mm screw-in depth in the enclosure). The conductor bushings are generally screwed in from the inside of the flameproof enclosure (inverted installation is only possible by using a special lock; upon request). The bushings must be secured against self-loosening by using backing strips or epoxy adhesives (see illustrations 1). Fig. 1 Threaded conductor bushing 8174/1 8867E The plain type bushings can be inserted directly into the corresponding hole drilled in the enclosure. Flameproof sealing is established via a cylindrical gap between enclosure and bushing. Observe the tolerances given in the operating instructions when using this method. The installation is simplified by using a threaded fitting, having the threaded gap on the outside (min. thread turns according toi tolerance from ISO 96-1 and ISO 96-3b) and cylindrical gap on the inside. A flameproof seal is thus ensured (see illustrations 2). The threaded fitting is also secured against self-loosening by using tab strips or adhesive. Fig. 2 8868E Plain conductor bushings 8174/2, fitted into threaded fitting Current Load Diagram (for Bunched Conductors of Various Temperatures), mm² of cables in M16 x 1, 1, mm² of cables in M24 x 1, 1, mm² of cables in M33 x 1, / ø 34 1 1 1 1 8 C 9 C 1 C 1 C 1 1 1 8 C 9 C 1 C 1 C 1 1 1 8 C 9 C 1 C 1 C 9449E2 94E2 9447E2 /4 Components for System Solutions 21-6 EK III de

Current Load Diagram (for Bunched Conductors of Various Temperatures), mm² of cables in M42 x 1, / ø 41 1 1 1 8 C 9 C 1 C 1 C, mm² of cables in M48 x 1, / ø 48 1 1 1 8 C 9 C 1 C 1 C,7 mm² of cables in M16 x 1, 1 1 1 1 1 8 C 9 C 1 C 1 C 9448E2 941E2 9446E2,7 mm² of cables in M24 x 1, 1,7 mm² of cables in M33 x 1, / ø 34 1,7 mm² of cables in M42 x 1, / ø 41 1 1 1 1 1 8 C 9 C 1 C 1 C 1 1 1 1 8 C 9 C 1 C 1 C 1 1 1 1 8 C 9 C 1 C,7 mm² of cables in M48 x 1, / ø 48 1 944E2 732E2 7321E2 1, mm² of cables in M16 x 1, 2 1, mm² of cables in M24 x 1, 2 1 1 1 1 8 C 9 C 1 C 1 C 2 1 1 1 1 1 8 C 9 C 1 C 1 C 2 1 1 1 1 1 8 C 9 C 1 C 1 C 1, mm² of cables in M33 x 1, / ø 34 2 9444E2 9442E2 9443E2 1, mm² of cables in M42 x 1, / ø 41 2 1, mm² of cables in M48 x 1, / ø 48 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 2 1 1 1 1 1 8 C 9 C 1 C 1 C 2 1 1 1 1 1 8 C 9 C 1 C 1 C 7326E2 7328E2 944E2 2, mm² of cables in M24 x 1, 3 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 2, mm² of cables in M33 x 1, / ø 34 3 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 2, mm² of cables in M42 x 1, / ø 41 3 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 9441E2 7327E2 733E2 21-6 EK III de Components for System Solutions /

Current Load Diagram (for Bunched Conductors of Various Temperatures) 2, mm² of cables in M48 x 1, / ø 48 3 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 4 mm² of cables in M24 x 1, 4 3 3 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 4 mm² of cables in M33 x 1, / ø 34 4 3 3 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 9439E2 9438E2 7322E2 4 mm² of cables in M42 x 1, / ø 41 4 3 3 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 6 mm² of cables in M24 x 1, 4 4 3 3 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 6 mm² of cables in M33 x 1, / ø 34 4 4 3 3 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 7329E2 9436E2 9437E2 6 mm² of cables in M42 x 1, / ø 41 4 4 3 3 2 2 1 1 1 1 1 8 C 9 C 1 C 1 C 1 mm² of cables in M33 x 1, / ø 34 7 6 4 3 2 1 1 1 1 8 C 9 C 1 C 1 C 1 mm² of cables in M42 x 1, / ø 41 7 6 4 3 2 1 1 1 1 8 C 9 C 1 C 1 C 7331E2 943E2 7334E2 16 mm² of cables in M42 x 1, / ø 41 1 9 8 7 6 4 3 2 1 1 1 1 8 C 9 C 1 C 1 C 16 mm² of cables in M48 x 1, / ø 48 1 9 8 7 6 4 3 2 1 1 1 1 8 C 9 C 1 C 1 C 2 mm² of cables in M42 x 1, / ø 41 14 12 1 8 6 4 2 1 1 1 8 C 9 C 1 C 1 C 7333E2 7324E2 7332E2 2 mm² of cables in M48 x 1, / ø 48 14 12 1 8 6 4 2 1 1 1 8 C 9 C 1 C 1 C 3 mm² of cables in M42 x 1, / ø 41 16 14 12 1 8 6 4 2 1 1 1 8 C 9 C 1 C 1 C 3 mm² of cables in M48 x 1, / ø 48 16 14 12 1 8 6 4 2 1 1 1 8 C 9 C 1 C 1 C 9434E2 9433E2 7323E2 /6 Components for System Solutions 21-6 EK III de

Accessories and Spare Parts Designation Illustration Description Order number Weight Stopping plug to close up unused thread fittings kg d 34 mm M42 x 1. 13972.267 13E d 41 mm M48 x 1. 139732.267 d 48 mm M6 x 1. Note: screws and washers have to be ordered separately 13974.267 Threaded fitting for plain conductor bushings 8174/2 Thread diameter Thread size 243E d 34 mm M42 x 1. d 41 mm M48 x 1. 1432.16 1438.184 d 48 mm M6 x 1. 1449.276 Allen screw 244E Note: screws and washers have to be ordered separately M4 x 6 3 cylinder-head screws are required per stopping plug or threaded fitting 1986.2 Spring washer 14E M4 3 spring washers are required per stopping plug or threaded fitting 1196.2 Lock nut M16 x 1. 18368.4 M33 x 1, 1837.36 86E M42 x 1, 18378.36 M48 x 1. 18379.4 Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Conductor size L R.... 1. mm 2 3 9 2. mm 2 3 12 4 mm 2 3 1 6 mm 2 3 17 1 mm 2 43 21 16 mm 2 43 28 2 mm 2 43 36 3 mm 2 43 4 mm 2 43 74 7 mm 2 43 83 Type G SW Ld / Le 8174/11-...-.. M16 x 1. 19 8174/12-...-.. M24 x 1. 27 8174/13-...-.. M33 x 1. 36 1 / 1 8174/14-...-.. M42 x 1. 46 8174/1-...-.. M48 x 1. 446E 8174/1..-...-.. Threaded conductor bushings 21-6 EK III de Components for System Solutions /7

Dimensional Drawings (All Dimensions in mm) - Subject to Alterations Conductor size L R.... 1. mm 2 3 9 2. mm 2 3 12 4 mm 2 3 1 6 mm 2 3 17 1 mm 2 43 21 16 mm 2 43 28 2 mm 2 43 36 3 mm 2 43 4 mm 2 43 74 7 mm 2 43 83 Type H D Ld / Le 8174/23-...-.. 38 34 8174/24-...-.. 48 41 13 / 13 8174/2-...-.. 8 48 429E 8174/2..-...-.. Plain conductor bushings 428E Essential machining contour in housing wall for plain type conductor bushing for type G SW a b c 8174/23-... M42 x 1. 46 16 31 3 8174/24-... M48 x 1. 16 31 3 8174/2-... M6 x 1. 6 16 31 3 Threaded fitting for plain type conductor bushing for type D D1 A E 8174/23-... 34 38.4 27 21.7 8174/24-... 41 48.4 27 26.7 8174/2-... 48 8.4 33 31.7 427E We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /8 Components for System Solutions 21-6 EK III de