Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Similar documents
Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Direct Operated Precision Regulator Modular Style. Standard Specifications

Related Products: Auto Drain Valve. Model/Specifications. Model

Series IRV1000/2000/3000

Series AMJ. Drain Separator for Vacuum

Pilot Check Valve: Metal Body Type

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

PVC Quick Drain Valve

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Power Valve: Precision Regulator. High precision, large capacity relief regulator

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

Regulator/Modular Style AR1000 to 6000

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

How to Order RM0 0 Z. IN/OUT fitting type Metric size Inch size Straight Elbow Straight Elbow Straight Elbow Straight Elbow ø ø ø ø ø ø ø ø ø/ ø/ ø/ ø

Clean Regulator/Fluororesin Type

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

Smooth Vent Valve. Series XVD XL XL Q D- XVD XGT CYV

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Coiling Tube with Twist-Proof Fitting

Low torque Metal seal type Rotary joint

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Smooth Vent Valve XVD. Series

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Smooth Vent Valve. XVD Series

Precision Regulator. Series Model Regulating pressure range Port size Page

Standard Specifications

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Operation Manual Air Saver Unit ASV5000 Series

Pressure Dump Valve Service Kit for Series 2300 Units

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

IR1000-A IR1010-A IR1020-A

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Modular Type Regulators

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Standard style

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Filter-Regulator-Lubricator

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

Air operated valve. VGA342R Series

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

F.R.L. Units Precautions 1 Be sure to read this before handling.

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Push-In Fitting Type with Stop Valve

MEGR-1627 Instruction Manual

Miniature Tubing & Miniature Fittings

Installation, Operation, and Maintenance Manual

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Related products. Components for air preparation and pressure adjustment / F.R.L. unit. Pressure gauge. Indidcator

Specifications. JIS Symbol 2 port valve 3 port valve (A) 2 (A) 2. Construction. 2 port valve/series VHK2 3 port valve/series VHK3.

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Push-In Fitting Type Silencer

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

Cautions : 1. The gauge orientation on the GPU and GPM types can be changed by using

MEGR-1912 Instruction Manual

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Push-In Fitting Type Pressure Gauge

F.R.L. Units Precautions 1 Be sure to read this before handling products.

Booster Regulator/Air Tank

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Filter-Regulator-Lubricator

Ball Valve Series. Push-In Fitting Type Shut-off Valve. Control Open/Close Air Supply. Ensure Effective Area for Variety of Tube Dia.

Automatic Non-freeze Valve NF6

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

Installation, Operation, and Maintenance Manual

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Compact Manometer. Pressure measurements can easily be taken any time, anywhere.

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

VOLUME BOOSTER RELAYS YT-300 / 305 SERIES

Precision and Instrument Regulators 1/4" port size

VACUUM REGULATORS CONTENTS

Pressure Gauge Series

Wafer Check Valve. Contents. User s Manual. (1) Be sure to read the following description of our product warranty 1

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Clean Speed Controller with One-touch Fitting

Manual Actuated Boiler Blowdown Valves

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

P5513. Users Manual. Pneumatic Comparison Test Pump. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Transcription:

Regulator for 2 MPa RX 2 How to Order RX2 1 Regulator 1 Regulating pressure.5 to.85mpa {.51 to 8.7kgf/cm²}.5 to.3mpa {.51 to 3.1kgf/cm²} Thread type Nil N F Rc(PT) NPT (PF) Port size 1 2 ccessories/options Bracket Pressure gauge RX2 {.51 to 8.7kgf/cm²} RX21 {.51 to 3.1kgf/cm²} 13481 36 1 1 46 1 2 36 4 1 46 4 2 134811 Specifications Regulator construction Relief mechanism Piping port size Pressure gauge port size Proof pressure Maximum operating pressure Standard type Regulating pressure range Low pressure type Fluid mbient and fluid temperature Weight RX2 Piston type regulator Relief type Rc(PT), Rc(PT), 3.MPa {3.6kgf/cm²} 2.MPa {2.4kgf/cm²}.5 to.85mpa {.51 to 8.7kgf/cm²}.5 to.3mpa {.51 to 3.1kgf/cm²} ir 5 to 6 C (with no freezing) 11g 1.5-43

Regulator for 2 MPa RX 2 Flow rate characteristics RX2-1 RX21-1 Pressure characteristics RX2.9.8.7.6.5.4.3.2.1 1 2 3 4 5 6 7 8 9 1.35.3.25.2.15.1.5 5 1 15 2 25 3 35 4 45 5 Conditions: Upstream pressure 2.MPa Downstream pressure.8mpa Flow rate 6l/min (NR).89.88.87.86.85.84.83.82.81.8 Set point.9 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2 Upstream pressure MPa RX2-2 RX21-2 RX21.35.3.25.2.15.1.5.37.36.35.34.33.32.31 Conditions: Upstream pressure 2.MPa.9.8.7.6.5.4.3.2.1 1 2 3 4 5 6 7 8 9 1 5 1 15 2 25 3 35 4 45 5 Conditions: Upstream pressure 2.MPa Downstream pressure.3mpa Flow rate 6l/min (NR).3 Set point.9 1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2 2.1 2.2 Upstream pressure MPa C V U F R IR VEX SRP W MR WM WD ITV VB L Construction JIS Symbol Parts list No. 1 2 3 Description Body Bonnet Handle DC POM POM Note Replacement parts list SUP No. 4 5 6 Description Piston assembly Valve Valve spring POM/NBR Brass/NBR Stainless steel 134814 134815 134819 1.5-44

RX 2 25 1 31.5 79.5 (when regulating pressure = 82) 1.6 (max. thickness 4.5) 54 44 5.4 35 Panel cutout dimensions SUP ø26 R2.5 SMC PUSH LOCK ø37 Options 134811 POM, NBR (gasket) Bracket 13481 SPCC (black zinc chromated) 44 24 11 5.4 1.5 ø34 asket Max. panel thickness 4.5mm 41.5 17 25 1.6 ø26 54 R16.5 ø24 4-R2.5 Install the gasket underneath the panel and bracket (bonnet side). Tighten the panel nut by hand without the use of tools. 1.5-45

Options Pressure gauge Dimension table 36 1 46 2 Specifications Piping port size Scale angle s Weight s 36 2 1 46 2 2 36 4 1 46 4 2 36 7 1 46 7 2 36 1 1 46 1 2 37 42 Case Clear cover Stem ø B 4.8 44.5 MPa to.2 to.4 to.7 to 1. C 23.8 24.5 36 1 R(PT) Pressure range C D 1 kgf/cm² to 2 to 4 to 7 to 1 B F E 4 6 F 14 46 2 R(PT) 27 Rolled steel plate (black melamine coated) Polycarbonate Brass 55g 8g D E Indicator units MPa kgf/cm² combined Regulator for 2 MPa RX 2 Instructions for Pressure auge with Limit auge Indicators Removing the Cover rasp the outer edge of the front cover with your fingers, push it in while turning to the left (about 6 to 7mm) until it stops, and then pull it off. Setting the Indicator Needles Move the indicator needles with your fingers. If it is done with a small screw driver, etc., take care not to bend the indicator needles or scratch the gauge dial. There are 2 green indicator needles, to be set at the upper and lower limits of the pressure range. Upper limit.6mpa {6.1kgf/cm 2 } Installing the Cover fter setting the indicator needles, return the cover to its original position by aligning the indentation at the top of the black case with the notch in the cover, and then pushing the cover back into place. Turn the cover to the right (about 6 to 7mm) until it stops, and confirm that the cover is firmly in place. C V U F R IR VEX SRP W MR WM WD ITV VB L Pressure auge Precautions Be sure to read before handling. Selection 1. void use in locations with strong pressure pulsation or vibration. 2. Contact SMC if the product will be used in an application with a high frequency of operation. 1. Do not subject the gauge to impacts, such as dropping, during transportation and mounting. This can cause loss of indication accuracy. 2. Do not use in locations with high temperature and humidity. This can cause malfunction. 3. When screwing the pressure gauge into place, be sure to apply your wrench on the square wrench flats. If the wrench is applied on any other area, air leakage or damage can occur. 1.5-46

Regulator for 2 MPa RX 2/Precautions Be sure to read before handling. Design & Selection 1. Confirm the specifications. The products appearing in this catalog are designed for use only in compressed air systems. Do not use outside the specified ranges of pressure, temperature, etc., as this may cause damage or faulty operation. Consult with SMC if fluids other than compressed air are to be used. 2. Confirm the regulating pressure range. Be sure to install safety devices in locations where output pressure above the regulating pressure range can lead to damage or malfunction of equipment downstream. 3. Residual pressure relief without supply pressure. In cases where the supply pressure is removed with the downstream pressure in a low pressure setting state, it may not be possible to eliminate the downstream pressure (residual pressure relief). Provide a residual pressure relief circuit for cases in which reliable elimination of downstream pressure must be performed. 4. When used with a closed downstream circuit and balance circuit. Contact SMC as there are cases in which the product cannot be used. 5. Perform downstream pressure setting in a range that is 85% or less of the supply pressure. However, the setting should be performed within the regulating pressure range. 1. Read the instruction manual carefully. The product should be mounted and operated with a good understanding of its contents. lso, keep the manual where it can be easily referred to at any time. 2. Ensure space for maintenance. Ensure the necessary space for maintenance activities. 3. Strictly observe the fastening of screws and their tightening torques. When mounting is performed, use the recommended tightening torques in the table below. PT, NPT, PF Recommended tightening torque 7 to 9N m to 14N m 1. To set the correct pressure 1. Set the pressure by increasing from a lower pressure to the desired setting, and lock the handle after the pressure is set. 2. Make connections after confirming the "SUP" mark which indicates the air inlet. Reversed connections will cause malfunction. Piping 1. Preparation before piping. Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove cutting chips, cutting oil and other debris from inside the pipe. 2. Wrapping of pipe tape. When screwing together pipes and fittings, etc., be certain that cutting chips from the pipe threads and sealing material do not get inside the piping. Further, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. ir Supply 1. Types of fluid. This product is designed for use with pressurized air. Consult with SMC if a different fluid is to be used. 2. Type of air Compressed air which contains substances such as organic solvents, synthetic oils, chemicals, salt, or corrosive gases can cause damage and malfunction of equipment. Operating Environment 1. Do not operate in locations having an atmosphere of corrosive gases, chemicals, sea water, fresh water or water vapor, or where there will be contact with the same. 2. In locations which receive direct sunlight, the sunlight should be blocked. 3. Do not operate in locations where vibration or impact occurs. 4. Do not operate in a location near a heat source or where radiated heat will be received. Maintenance 1. Maintenance operations. Improper handling of compressed air is dangerous. Therefore, in addition to observing the product specifications, replacement of elements and other maintenance activities should be performed by personnel having sufficient knowledge and experience pertaining to pneumatic equipment. 2. Pre-maintenance inspection. When removing this product, turn off the electric power, and be certain to shut off the supply pressure and exhaust the compressed air in the system. Proceed only after confirming that all pressure has been released to the atmosphere. 3. Post maintenance inspection. fter installation, repair or reconstruction, reconnect pressurized air and electric power, and then perform inspections for proper operation and air leakage. If the sound of air leakage can be heard, or if the equipment does not operate properly, stop operation and confirm that it is mounted correctly. 4. Modification prohibited. Do not modify or reconstruct the unit. 1.5-47