Booster Regulator/Air Tank

Similar documents
Booster Regulator/Air Tank

Air Tank for Booster Regulator Compliant with ASME Standards

Booster Regulator/Air Tank

Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Series VBA1110 to 4200

VBA1110 to 4200 VBA /4 (IN/OUT) 1/4

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Chinese Pressure Vessel Regulations Compliant Product Air Tank for Booster Regulator

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

Related Products: Auto Drain Valve. Model/Specifications. Model

Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and

Direct Operated Precision Regulator Modular Style. Standard Specifications

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Precision Regulator. Series Model Regulating pressure range Port size Page

Series IRV1000/2000/3000

Pilot Check Valve: Metal Body Type

Booster Regulator/Air Tank Increase factory air pressure by up to twice as much! Air-only operation requires no power supply, reduces

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

EXH. Specifications. Descriptions. Min. working pressure MPa

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

VACUUM REGULATORS CONTENTS

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Process Pump. Series PAF3000/Series PAF5000

Air Saving Valve. Pressure Valve Flow Valve

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

ALF400 to 900, ALT-5/-9

Process Pump. PAF3000 Series/PAF5000 Series

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Type 4708 Supply Pressure Regulator

Type 4708 Supply Pressure Regulator

Push-In Fitting Type Silencer

How to Order. Rc NPT 1/8 1/4 3/8 1/2

Air Saving Valve reduction in 40% air consumption 40% air consumption Air consumption reduction ratio (%) Flow valve Flow valv

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Clean Speed Controller with One-touch Fitting

ALF400 to 900, ALT-5/-9

Standard Specifications

Regulator/Modular Style AR1000 to 6000

Mounting and Operating Instructions EB 8546 EN. Type 4708 Supply Pressure Regulators. Translation of original instructions. Type Type

Air Saving Valve. Series ASQ. Series ASR. Pressure Valve. Flow valve TMH ASD AS AS-FG AS-FP AS-FM ASP ASN AQ ASV AK VCHC ASS. r r AS-FE KE 10 0.

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Coiling Tube with Twist-Proof Fitting

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

Clean Regulator/Fluororesin Type

Operation Manual Air Saver Unit ASV5000 Series

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

Modular Type Regulators

IR1000-A IR1010-A IR1020-A

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

Type Pressure Regulator. for increased air capacity. Fig. 1: Type Pressure Regulator. Mounting and Operating Instructions EB EN

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

OWNER S TECHNICAL MANUAL

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

Regulator. Modular Type AR10 AR20 AR25 AR30 AR40 AR40-06 AR50 AR60. Pages 36 through 40 AR20K AR25K AR30K AR40K AR40K-06 AR50K AR60K

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA. Q = C v P S

The Compact, Portable, Efficient and Economical Solution to boost Shop Compressed Air Pressure by 2 or 3 times

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.

Series AMJ. Drain Separator for Vacuum

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

Pressure booster combination DPA-CRVZS. Operating instructions a [ ]

Mounting and Operating Instructions EB 8546 EN. Supply Pressure Regulator Type Fig. 1 Supply pressure regulators

Air operated valve. VGA342R Series

Type 4708 Supply Pressure Regulator

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Push-In Fitting Type Pressure Gauge

TECHNICAL DATA. Q= Cv S

Model GPR Primary Pressure Regulating Valve. Instruction Manual

PVC Quick Drain Valve

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Unit 24: Applications of Pneumatics and Hydraulics

ALF400 to 900, ALT-5/-9

Flow Characteristics NAR1 NAR 9 6 M5X.8 NAR2 NPT 3/ Flow (scfm) NAR5 NPT 3/ Flow (scfm) Flow (

Air preparation units

Increase factory air pressure by up to twice as much! No need for an electrical supply!

Standard Specifications. Fluid Proof pressure Maximum operating pressure. Regulating pressure range

TECHNICAL DATA CAUTION

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

Push-In Fitting Type with Stop Valve

Filter-Regulator-Lubricator

Filter-Regulator-Lubricator

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

Speed Controller Anti-spatter Series

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

RP series Rotor Pumps

Transcription:

Booster Regulator/Air Tank /T Series Increase factory air pressure by up to 4 times! RoHS the hinese pressure vessel Air-only operation requires no power supply, Except regulations compliant product (-X04) reduces heat generation, and Boost pressure Heavy allows easy installation. Renewed model with pressure increase ratio 2 to 4 times (A) ARM Factory line ARP Booster Regulator + Air Tank 0.3 MPa ARX AMR 0.6 MPa 0.3 MPa ARJ AR425 to 935 IR -A 0.3 MPa IR Light IRV ompressor 0.3 MPa VEX Light SRH No power supply or wiring needed There is no need to install dedicated electrical wiring. Easy installation SRP Simply install the unit in the air line. Requires far less space than installing the compressor. SRF ITV I Low heat generation Very little heat is generated because no electricity is used, and there is no impact on cylinders, solenoid valves, etc. ITVH Air-only operation ITVX Operation is safe because no electricity is used. PVQ VY T AP00 Booster Regulator/ Series Air Tank/T Series 007

Booster Regulator Series Improved service life Doubled Floating piston structure Grease retaining groove Except 0A, A that of the current model Grease retaining groove Reduced noise Reduced by 3 db compared with the current model Metal noise reduced by a bumper on the impact part of the switch valve Exhaust noise reduced by a highnoise reduction silencer Switching valve Floating structure Bumper Improved reliability Anti-condensation Built-in mesh filter at Prevents operation failure due to foreign matter. Mesh filter Integrated air-feeding tube with the main tube Mitigates condensation caused by cooling during exhaust expansion. ylinder tube Tie-rod guide Air-feeding tube 20A 40A Elbow silencer added (Option) Space saving when installed has been realized. Except 2A, 4A Elbow silencer /8" gauge ports Allows use of standard fittings for remote pressure monitoring, etc. Gauge ports changed from /6" to /8" (A, 2A) 0A Gauge port Air-operated type Max. operating pressure.6 MPa Fourfold pressure increase type 22A 43A A 008 42A

P.00 Pressure increase ratio Body size /4" Operation Set pressure range 0.2 to.0 MPa Knob-operated type (Direct operation) Twice 0.2 to.6 MPa (2.0 MPa) 0A-02 (0.2 to 2.0 MPa) Air-operated type (Remote operation) 0.2 to.0 MPa 2 to 4 times Knob-operated type (Direct operation) 0.2 to 2.0 MPa A-02 ARJ AR425 to 935 ARX AMR ARM ARP 20A-03 22A-03 IR-A IR " IRV VEX SRH 40A-04 43A-04 (0.2 to.6 MPa) 42A-04 SRP SRF /2" ITV I ITVH ITVX Air Tank T Series Perfect fit with a booster regulator This is an air tank to which a booster regulator can be connected compactly. It can be used alone as a tank. The pressure vessel law is different from country to country, so as an air tank suitable to a country needs to be confirmed. P.022 PVQ VY T AP00 Extensive product lineup To meet a variety of usage environment and pressure specifications, models are available in two materials, stainless steel 304 and carbon steel (SS400), and in four sizes ranging from 5 liters to 38 liters. Model Tank capacity (L) Max. operating pressure (MPa) Material T05A T0A T20A T38A 5 0 20 38 2.0.0 arbon steel Model Tank capacity (L) Max. operating pressure (MPa) Material T05S 5 T0S T20S 0 20 2.0 Stainless steel T38S 38 aution When used as a single unit (not connected with a booster regulator) and pressurized at over MPa at normal temperatures, the air tank falls under the scope of the High Pressure Gas Safety Act in Japan. 009

Booster Regulator Series How to Order RoHS Made to Order (For details, refer to page 020.) 0A 20A 40A 22A 42A 43A /4", Knob-operated type ", Knob-operated type /2", Knob-operated type ", Air-operated type /2", Air-operated type /2", Max. operating pressure.6 MPa 40A 04 Body size Pressure increase ratio: Twice Pressure increase A Note) /4", Knob-operated type ratio: 2 to 4 times Note) Set the pressure increase ratio to 2 or more. Thread type Note) Symbol Thread type Symbol Nil Rc F G N NPT T NPTF Note) Thread types apply to the IN,, and EXH ports of the A and to the IN,, EXH, and gauge ports of the 2A and 4A. The gauge ports of the A are Rc thread type regardless of the thread type indication. 0A-02 A-02 Symbol 02 03 04 Port size /4 /2 Port size Applicable series A 2A 4A Semi-standard Symbol Semi-standard Nil Standard product Pressure unit on the product name label: psi Z Note) Pressure unit on the pressure gauge: MPa and psi Note) Thread type: NPT, NPTF Under the new measurement law, the pressure unit of psi on the pressure gauges cannot be used in Japan. Option Symbol Option Nil None G Pressure gauge N Silencer S High-noise reduction silencer Note) GN Pressure gauge, Silencer GS Pressure gauge, High-noise reduction silencer Note) LN Elbow silencer Note) LS Elbow high-noise reduction silencer Note) GLN Pressure gauge, Elbow silencer Note) GLS Pressure gauge, Elbow high-noise reduction silencer Note) Note) Refer to ombination of Thread Type and Options. Pressure gauge Pressure gauge Silencer Elbow silencer 20A-03 22A-03 ombination of Thread Type and Options Body size Thread Option type Nil G N S GN GS Nil 0A A F N T Nil 20A 22A F N T Nil 40A F 42A N 43A T LN LS GLN Semi-standard GLS Nil -Z 42A-04 40A-04 43A-04 Air Tank ompatibility hart Booster regulator 0A/A 20A/22A 40A/42A Air tank T05A() T05S() T0A() T0S() T20A() T20S() T38A() T38S() 43A 00

Booster Regulator Series Standard Specifications Model Fluid Pressure increase ratio Pressure adjustment mechanism Max. flow rate Note 3) (L/min (ANR)) 230 000 900 000 900 0 70 Set pressure range (MPa) 0.2 to 2.0 0.2 to.0 0.2 to.0 0.2 to.6 0.2 to 2.0 Supply pressure range (MPa) 0. to.0 Proof pressure (MPa) 3.5 2.4 3 Port size (Rc) (IN//EXH: 3 locations) /4 /2 /2 /4 Pressure gauge port size (Rc) (IN/: 2 locations) /8 Note 5) Tank connection port (with plug) /4 /2 /2 /4 Ambient and fluid temperature ( ) 2 to (No freezing) Installation Horizontal Lubrication Grease (Non-lube) Weight (kg) 0.84 3.9 8.6 3.9 8.6 8.6 0.89 Note ) Be sure to secure an air supply capacity of the minimum operating pressure (0. MPa) or more. Note 2) If the pressure is higher than the set pressure by the knob, excess pressure is exhausted from the back of the knob. Note 3) Flow rate at IN= = 0.5 MPa. The pressure varies depending on the operating conditions. Refer to Flow Rate haracteristics on pages 02 and 03. Note 4) Set the pressure increase ratio to 2 or more. Note 5) The tank connection port cannot be used for applications other than the connection with T. Options/Part No. Related Products/Part No. Mist Separator, Exhaust leaner Model Description Mist separator Exhaust cleaner For 0A-02 For 20A-03 For A-02 For 22A-03 AM2-02 AM30-03 Note) Refer to page 022 for air tanks, page 223 for mist separators and Best Pneumatics No.7 for exhaust cleaners. Refer to the separate operation manual for the connection method. Design AM4-04, 06 AM-06 For 40A-04 For 42A-04 For 43A-04 AM5-06, 0 AM-0 aution. System configuration Be sure to secure an air supply capacity of the minimum operating pressure (0. MPa) or more. If the internal operating pressure becomes the minimum operating pressure or less, the 0A-02 20A-03 40A-04 22A-03 42A-04 43A-04 A-02 ompressed air Twice 2 to 4 times Note 4) Knob-operated with relief mechanism Note 2) Air-operated Pressure Gauge, Silencer (When thread type is Rc or G.) Model 0A-02 20A-03 40A-04 Description 0A-F02 20A-F03 40A-F04 Pressure gauge G G27-20-0 G36-0-0 Silencer High-noise reduction silencer Elbow for silencer N S L AN20-02 ANA-02 KT-0A-8 AN30-03 ANA-03 AN40-04 ANA-04 22A-03 22A-F03 KT-22A-7 AN30-03 ANA-03 42A-04 42A-F04 G36-0-0 AN40-04 ANA-04 Note ) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories. Note 2) KT-22A-7 is a pressure gauge with fitting. (Please order two units when using with IN and.) Knob-operated with relief mechanism Note 2) 43A-04 43A-F04 G27-20-0 AN40-04 ANA-04 A-02 A-F02 G27-20-0 AN20-02 ANA-02 KT-0A-8 Pressure Gauge, Silencer (When thread type is NPT or NPTF.) Model 0A-N02 20A-N03 40A-N04 22A-N03 42A-N04 43A-N04 A-N02 0A-T02 20A-T03 40A-T04 22A-T03 42A-T04 43A-T04 A-T02 Description : when -Z : when -Z : when -Z : when -Z : when -Z : when -Z : when -Z Pressure gauge : when Nil G27-20-0 G36-0-N0 KT-22A-7N G36-0-N0 G27-20-N0 G27-20-0 G Pressure gauge : when -Z Note 4) G27-P20-0-X30 G36-P0-N0-X30 KT-22A-8N G36-P0-N0-X30 G27-P20-N0-X30 G27-P20-0-X30 Silencer High-noise reduction silencer Elbow for silencer N S L AN20-N02 KT-0A-8N AN30-N03 ANA-N03 AN40-N04 ANA-N04 AN30-N03 ANA-N03 AN40-N04 ANA-N04 AN40-N04 ANA-N04 AN20-N02 KT-0A-8N Note ) In the case of options GN, two pressure gauges and one silencer are included in the same container as accessories. Note 2) KT-22A-7N, KT-22A-8N are pressure gauges with fittings. (Please order two units when using with IN and.) Note 3) Under the new measurement law, the pressure unit of psi on the pressure gauges cannot be used in Japan. Note 4) Pressure unit on the pressure gauge: MPa and psi switching valve may remain in the intermediate position, which may cause a restart failure. The of the booster regulator has metallic mesh to prevent dust from entering the booster regulator. However, it cannot remove dust continuously or separate drainage. Make sure to install a mist separator (AM series) on the inlet side of the booster regulator. The booster regulator has a sliding part inside, and it generates dust. Also, install an air purification device such as an air filter or a mist separator on the outlet side as necessary. onnect a lubricator to the outlet side, because the accumulated oil in the booster regulator may result in a malfunction. 2. Exhaust air measures Provide a dedicated pipe to release the exhaust air from each booster regulator. If exhaust air is converged into a pipe, the back pressure that is created could cause improper operation. Depending on the necessity, install a silencer or an exhaust cleaner on the exhaust port of the booster regulator to reduce the exhaust noise. 3. Maintenance space Allow the sufficient space for maintenance and inspection. 0 ARJ AR425 to 935 ARX AMR ARM ARP IR-A IR IRV VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00

Series 0A Flow Rate haracteristics 2 20A, 22A Flow Rate haracteristics.0 40A, 42A Flow Rate haracteristics.0 Outlet pressure (MPa).5 0.5 P =.0 MPa P = 0.75 MPa P = 0.5 MPa P = 0.4 MPa P = 0.3 MPa P = P2 Outlet pressure (MPa) 0.8 0.6 0.4 0.2 P = 0.3 MPa P = 0.5 MPa P = 0.4 MPa Outlet pressure (MPa) 0.8 0.6 0.4 0.2 P = 0.5 MPa P = 0.4 MPa P = 0.3 MPa. 0 00 300 400 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) (Representative value).04 0 400 0 800 000 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) (Representative value).04 0 0 000 0 0 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) (Representative value).05 Set point.02 Set point.02 Set point Outlet pressure (MPa).0 0.95 0.9 0.85 Outlet pressure (MPa).0 0.98 0.96 Outlet pressure (MPa).0 0.98 0.96 0.8 0.94 0.94 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) harge haracteristics harge time per 0 L t (s) 40 30 20 0 0A 0.0.2.4.6.8 2.0 Pressure increase ratio P2/P The time required to charge pressure in the tank from 0.7 MPa to 0.95 MPa at 0.5 MPa supply pressure: P2 P With the pressure increase ratio from.4 to.9, the charge time of 23 6 = 7 sec. (t) is given by the graph. Then, the charge time (T) for a 0 L tank: harge haracteristics harge time per 0 L t (s) 2 0 9 8 7 6 5 4 3 2 0.0..2.3.4.5.6.7.8.9 2.0 Pressure increase ratio P2/P 20A, 22A The time required to charge pressure in the tank from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: = 0.7 0.5 =.4 P2 0.95 =.9 P2 0.8 =.6 P2.0 = = = = 2.0 P 0.5 P 0.5 P 0.5 V 0 T = t x = 7 x = 7 (s). 0 0 With the pressure increase ratio from.6 to 2.0, the charge time of.5 3.8 = 7.7 sec. (t) is given by the graph. Then, the charge time (T) for a 00 L tank: V 00 T = t x = 7.7 x = 77 (s). 0 0 harge haracteristics harge time per 0 L t (s) 5 4 3 2 0.0..2.3.4.5.6.7.8.9 2.0 Pressure increase ratio P2/P 40A, 42A The time required to charge pressure in the tank from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: P2 = 0.8 P 0.5 =.6 P2.0 = = 2.0 P 0.5 With the pressure increase ratio from.6 to 2.0, the charge time of 3.5. = 2.4 sec. (t) is given by the graph. Then, the charge time (T) for a 00 L tank: V 00 T = t x = 2.4 x = 24 (s). 0 0 02

Booster Regulator Series 43A Flow Rate haracteristics Outlet pressure (MPa) Outlet pressure (MPa) harge time per 0 L t (s).6.4.2 0.8 0.6 0.4 0.2.08.06.04.02.0 0.98 0.96 0.94 5 4 3 2 0 0 000 0 0 20 3000 Outlet air flow rate (L/min (ANR)) Pressure haracteristics P = 0.8 MPa P = 0.7 MPa P = 0.6 MPa P = 0.5 MPa P = P2 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) harge haracteristics 43A Inlet pressure: 0.7 MPa Outlet pressure:.0 MPa Flow rate: 20 L/min (ANR) Set point (Representative value) 0.0..2.3.4.5.6.7.8.9 2.0 Pressure increase ratio P2/P The time required to charge pressure in the tank from 0.8 MPa to.0 MPa at 0.5 MPa supply pressure: P2 = 0.8 P 0.5 =.6 P2.0 = = 2.0 P 0.5 With the pressure increase ratio from.6 to 2.0, the charge time of 4.5.3 = 3.2 sec. (t) is given by the graph. Then, the charge time (T) for a 00 L tank: A Flow Rate haracteristics Outlet pressure (MPa) Outlet pressure (MPa) harge time per 0 L t (s) 2 2. 2.05 2.0.95.9.85.8 400 300 00 P = 0.5 MPa P = 0.4 MPa P = 0.3 MPa 0 00 Outlet air flow rate (L/min (ANR)) Pressure haracteristics Set point P = 0.75 MPa Inlet pressure: 0.6 MPa Outlet pressure: 2.0 MPa Flow rate: 0 L/min (ANR) 0 0.4 0.5 0.6 0.7 0.8 0.9 Inlet pressure (MPa) harge haracteristics P =.0 MPa P = P2 (Representative value) 0.0 2.0 3.0 4.0 Pressure increase ratio P2/P A The time required to charge pressure in the tank from.0 MPa to.5 MPa at 0.5 MPa supply pressure: P2.0 P2.5 = = 2.0 = = 3.0 P 0.5 P 0.5 With the pressure increase ratio from 2.0 to 3.0, the charge time of 47 58 = 89 sec. (t) is given by the graph. Then, the charge time (T) for a 0 L tank: Pulsation/Pulsation is decreased with a tank. If the outlet capacity is undersized, pulsation may occur. T05A Max. pulsation range (MPa) Max. pulsation range (MPa) 0. 0.08 0.06 0.04 0.02 0. 0.08 0.06 0.04 0.02 T05A 0 2 3 4 5 apacity (L) A T T0A, 20A, 38A T0A T20A T38A 0 0 20 30 38 40 apacity (L) T 2A 4A onditions: Inlet pressure: 0.5 MPa Outlet set pressure: MPa Flow rate: Between 0 and max. flow rate Performance of air tank Alleviates the pulsation generated on the outlet side. When air consumption exceeds air supply during intermittent operation, required air will be accumulated in the tank for use. This does not apply for continuous operation. ARJ AR425 to 935 ARX AMR ARM ARP IR-A IR IRV VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00 V 00 T = t x = 3.2 x = (s). 0 0 V 0 T = t x = 89 x = 89 (s). 0 0 03

Series Please use the Booster Regulator Model Selection Software on the SM website, Sizing ( http://mssc.smcworld.com/brmss/ ) Tc Ts START Provide requisite conditions for selection. alculate required air flow rate Q. Select booster regulator size from flow rate characteristics table. P P3 Necessary conditions: D [mm]: ylinder bore size L [mm]: ylinder stroke W [mm/s]: ylinder operating speed [pc.]: Number of cylinders Tc [s]: ylinder operating time Ts [s]: ylinder stop time P [MPa]: Inlet pressure P2 [MPa] Note ) : Necessary supply pressure to cylinder Example 00 00 0.5 30 0.5 0.8 Pressure Stroke Upper limit of pressure inside the tank P3 Necessary supply pressure to cylinder P2 Lower limit of pressure inside the tank P2 Inlet pressure P Note ) P2 is the necessary supply pressure to a cylinder, and set the pressure below the lower limit of pressure inside the tank with a regulator. Adjust the pressure taking the maximum operating pressure of equipment in use into consideration. Note 2) P3 is the output pressure of the booster regulator, which is also the upper limit of charge pressure to the tank. Q [L/min (ANR)] = π x D2 x W x (P2 + 0.0) x x 4 x 0 6 0.0 Q = π x 002 x (0.8 + 0.0) x x x = 84 [L/min (ANR)] 4 x 0 6 0.0 2A: Qb = 0 [L/min (ANR)] 4A: Qb = 0 [L/min (ANR)] Refer to Flow Rate haracteristics on pages 02 and 03. P2 L ød Time Other conditions: Q [L/min (ANR)]: Required air flow rate Qb [L/min (ANR)]: Outlet air flow rate of booster regulator Tc [s]: ylinder operating time K: ylinder double-acting: 2, single-acting: P3 [MPa] Note 2) : Tank charge pressure T [s]: Time to charge (Time to charge to P2) T2 [s]: Time to charge (Time to charge to P3) T [s]: Time to charge (Time to charge from P2 to P3) Z: Number of booster regulators aution Set the pressure increase ratio of the A (pressure increase ratio 4) to 2 or more. When the A is used at a pressure increase ratio of 2 or less, this may cause a malfunction. Since the booster regulator is a compressor powered by the air, it consumes the air. The air consumption is approximately.2 times (pressure increase ratio 2) or 2.7 times (pressure increase ratio 4) larger than the outlet side volume. Therefore, the booster regulator requires a supply capacity of the inlet side volume that is approximately 2.2 times (pressure increase ratio 2) or 3.7 times (pressure increase ratio 4) larger than the outlet side volume. Judgement of flow rate NO: Need no tank The 4A can supply necessary pressure. Avoid pulsation. (Max. 0.05 MPa) NO YES The 2A cannot obtain necessary pressure. YES Obtain the tank capacity V. Select the tank capacity over V. alculate time T from charge characteristics table. (Q Qb/2) x (Tc x K/) V [L] = (P3 P2) x 9.9 (84 0/2) x (0.5 x 2/) V = = 4.6 [L] (.0 0.8) x 9.9 Select the T0, which can be directly connected to the 2A. Refer to harge haracteristics on pages 02 and 03. T [s] = ( V T2 ) x T 0 Z 4.6.5 3.8 T = ( ) x = 3.5 [s] 0 Internal Tank model capacity T05A() 5L T05S() T0A() 0L T0S() T20A() 20L T20S() T38A() 38L T38S() Select the tank from table below. 0A/A 0A/A Applicable combination model 20A/22A 20A/22A 20A/22A 40A/42A 40A/42A/43A 40A/42A 40A/42A/43A Judgement of charge time T Ts NO Extend stop time Ts up to charge time T or more. NO Increase number of booster regulators (Z) to decrease T. YES YES YES 04 END When running continuously for longer periods of time, confirm the life expectancy. When the life expectancy is shorter than required, select a larger sized booster regulator.

Booster Regulator Series Working Principle The IN air passes through the check valve to booster chambers A and B. Meanwhile, air is supplied to drive chamber B via the governor and the switching valve. Then, the air pressure from drive chamber B and booster chamber A are applied to the piston, boosting the air in booster chamber B. As the piston travels, the boosted air is pushed via the check valve to the side. When the piston reaches to the end, the piston causes the switching valve to switch, so that drive chamber B is in the exhaust state and drive chamber A is in the supply state respectively. Then, the piston reverses its movement, this time, the pressures from booster chamber B and drive chamber A boosts the air in booster chamber A and sends it to the side. The process described above is repeated to continuously supply highly pressurized air from the IN to the side. The governor establishes the outlet pressure by knob operation and pressure adjustment in the drive chamber by feeding back the outlet pressure. 0A, 20A, 40A, 43A Drive Governor chamber A Booster chamber A Switching valve ircuit Example IN (Inlet) heck valve E (Outlet) General line (low pressure) Drive chamber B Piston rod Piston Booster chamber B Locations requiring high pressure Air-operated type Pilot pressure 22A, 42A When only some of the machines in the plant require high-pressure air, booster regulators can be installed for only the equipment that requires it. This allows the overall system to use low-pressure air while accommodating machines requiring high-pressure air. P Plant line (source pressure) (Two-stage pressure boost) When charging a tank or the like from a source at atmospheric pressure, a circuit with a check valve can be used to reduce the charge time by allowing air to pass through the check valve up to the inlet pressure. P2 Piston rod Booster chamber A Piston When the actuator output is insufficient but space limitations prohibit switching to a larger cylinder diameter, a booster regulator can be used to increase the pressure. This makes it possible to boost the output without replacing the actuator. When a certain level of output is required but the cylinder size must be kept small so that the driver remains compact. 0.5 MPa ø00 Operating pressure: 0.5 MPa Bore size: ø00 Output 38 N Booster chamber B A IN (Inlet) heck valve (Outlet) E Equivalent output Governor Drive Drive chamber A chamber B 0.8 MPa ø80 E IN 0.5 MPa Operating pressure: 0.8 MPa Bore size: ø80 Output 4000 N Switching valve When only one side of the cylinder is used for work, booster regulators can be installed only on the lines that require them to reduce the overall air consumption volume. ARJ AR425 to 935 ARX AMR ARM ARP IR-A IR IRV VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00 Initially, inlet pressure (P) passes through the check valve, fills P2, and results in P = P2. Outlet pressure (MPa) P2 P Shortening time Without check valve by-pass 0 Time t (S) 05

Series Warning Design. Warning concerning abnormal outlet pressure If there is a likelihood of causing an outlet pressure drop due to unforeseen circumstances such as equipment malfunction, thus leading to a major problem, take safety measures on the system side. Because the outlet pressure could exceed its set range if there is a large fluctuation in the inlet pressure, leading to unexpected accidents, take safety measures against abnormal pressures. Operate the equipment within its maximum operating pressure and set pressure range. 2. Residual pressure measures onnect a 3-port valve to the side of the booster regulator if the residual pressure must be released quickly from the outlet pressure side for maintenance, etc. (Refer to the diagram below.) The residual outlet pressure side cannot be released even if the 3-port valve is connected to the IN side because the check valve in the booster regulator will activate. After operation is finished, release the supply pressure at the inlet. This stops the booster regulator from moving needlessly and prevents operating malfunctions. aution Mounting. Transporting When transporting this product, hold it lengthwise with both hands. Never hold it by the black knob that protrudes from the center because the knob could become detached from the body, causing the body to fall and leading to injury. 2. Installation Install this product so that the silver-colored tie-rods and cover are placed horizontally. If mounted vertically, it may result in a malfunction. Because the piston cycle vibration is transferred, use the following mounting bolts (: M5; 2, 4: M0) and tighten them with the specified torque (: 3 N m; 2, 4: 24 N m). If the transmission of vibration is not preferred, insert an isolating rubber material before installation. Mount the pressure gauge with a torque of 7 to 9 N m. aution Piping. Flushing Use an air blower to flush the piping to thoroughly remove any cutting chips, cutting oil, or debris from the piping inside, before connecting them. If they enter the inside of the booster regulator, they could cause the booster regulator to malfunction or its durability could be affected. 2. Piping size To bring the booster regulator s ability into full play, make sure to match the piping size to the port size. aution Selection. heck the specifications. onsider the operating conditions and operate this product within the specification range that is described in this catalog. 2. Selection Based on the conditions (such as pressure, flow rate and cycle time) required for the outlet side of the booster regulator, check the selection procedures described in this catalog or model selection software for size selection of the booster regulator. Since the booster regulator is a compressor powered by the air, it consumes the air. The air consumption is approximately.2 times (pressure increase ratio 2) or 2.7 times (pressure increase ratio 4) larger than the outlet side volume. Therefore, the booster regulator requires a supply capacity of the inlet side volume that is approximately 2.2 times (pressure increase ratio 2) or 3.7 times (pressure increase ratio 4) larger than the outlet side volume. Set the pressure of the 0A, 20A, 22A, 40A, 42A or 43A (pressure increase ratio 2) to a level that is at least 0. MPa higher than the inlet pressure. If the pressure differential is 0. MPa or less, the internal operating pressure becomes the minimum operating pressure or less and the switching valve may remain at the intermediate position, causing a restart failure. Set the pressure increase ratio of the A (pressure increase ratio 4) to 2 or more. When the A is used at a pressure increase ratio of 2 or less, the internal operating pressure becomes the minimum operating pressure or less and the switching valve may remain at the intermediate position, causing a restart failure. When operating the booster regulator continuously for longer periods of time, particularly confirm its service life. The service life of the booster regulator depends on not the operation hours but the operating cycles (piston sliding distance). The operating cycles (piston sliding distance) depend on the outlet flow of the booster regulator. Thus, when more outlet flow of the booster regulator is used, its service life becomes shorter. 06 aution Air Supply. Quality of air source onnect a mist separator to the inlet side near the booster regulator. If the quality of the compressed air is not thoroughly controlled, the booster regulator could malfunction (without being able to boost) or its durability could be affected. If dry air (atmospheric pressure dew point: 23 or less) is used, the life expectancy may be shortened because dry air will accelerate evaporation of grease inside. aution Operating Environment. Installation location Do not install this product in an area that is exposed to rainwater or direct sunlight. Do not install in locations influenced by vibrations. If it must be used in such an area due to unavoidable circumstances, please contact SM beforehand.

Booster Regulator Series aution. Setting the pressure on the knob-operated type If air is supplied to the product in the shipped state, the air will be released. Set the pressure by quickly pulling up on the governor knob, releasing the lock, and rotating the knob in the direction of the arrow (+). There is an upper and lower limit for the knob rotation. If over-rotating the knob even after reaching to the limit, the internal parts may be damaged. If the knob suddenly feels heavy while being turned, stop turning the knob. Once the setting is completed, push the knob down and lock it. To decrease the outlet pressure, after the pressure has been set, rotate the knob in the direction of the arrow ( ). The residual air will be released from the area of the knob, due to the relief construction of the governor. To reset the pressure, first reduce the pressure so that it is lower than the desired pressure; then, set it to the desired pressure. Low SM Outlet pressure MPa (Q = 0) 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0. High 2. Setting the pressure on the air-operated type (22A, 42A) onnect the outlet pipe of the pilot regulator for the remote control to the pilot port (P). (Refer to the diagram below.) Refer to the graph below for the relationship between the pilot pressure and outlet pressure. The AR20 and AW20 are recommended for the pilot regulator. Pilot regulator The outlet pressure is twice the pilot pressure. When the inlet pressure is 0.4 MPa: Pilot pressure 0.2 MPa to 0.4 MPa Outlet pressure 0.4 MPa to 0.8 MPa IN P E Handling 3. Draining If this product is used with a large amount of drainage accumulated in the filter, mist separator or tank, the drainage could flow out, leading to equipment malfunction. Therefore, drain the system once a day. If it is equipped with an auto drain, check its operation once a day. 4. Exhaust Exhausting time from E port may be longer for a booster regulator which is set to switch in longer hour intervals. This is not an abnormal phenomenon. 5. Maintenance Life expectancy varies depending on the quality of air and the operating conditions. Signs that the unit is reaching the end of its service life include the following: onstant bleed from under the knob. Air exhaust noise can be heard from the booster regulator at 0 to 20 second intervals even when there is no air consumption on the outlet side. onduct maintenance earlier than scheduled in such cases. When maintenance is required, confirm the model and lot number of the booster regulator, and please contact SM for maintenance kit. onduct maintenance according to the specified maintenance procedure by individuals possessing enough knowledge and experiences in maintaining pneumatic equipment. The list of replacement parts and kit number are shown on page 08, and the figure shows the position of the parts. ARJ AR425 to 935 ARX AMR ARM ARP IR-A IR IRV VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00 0 0. 0.2 0.3 0.4 0.5 Pilot pressure MPa 07

Series onstruction/replacement Parts 0A A q r e w t u r e w t q 20A, 22A, 40A, 42A, 43A t q y r w e Air-operated type q 22A, 42A Replacement Parts/Kit No. Place an order with the following applicable kit number. Model 0A 20A 40A 22A 42A 43A A Kit no. KT-0A- KT-20A- KT-40A- KT-22A- KT-42A- KT-43A- KT-A-20 The kit includes the parts from q to u and a grease pack. Model 0A 20A 40A 22A 42A 43A No. Description Quantity Piston seal 2 2 large small 2 2 Governor assembly 3 heck valve 4 4 5 6 Gasket Rod seal Mounting screw 8 2 2 8 2 7 over assembly Grease pack 2 2 The grease pack has 0 g of grease. Make sure to refer to the procedure for maintenance. 08 A each large and small 2

Booster Regulator Series Dimensions 0A-02 IN side gauge port Rc /8 A-02 IN side gauge port Rc /8 20A-03 IN side gauge port /8 40A-04 IN side gauge port /8 40 33 30 40 8.5 300 39 53 73 404 40 8.5 Pressure gauge (Option) side gauge port /8 3.2 Pressure gauge (Option) side gauge port Rc /8 3 3 Pressure gauge (Option) side gauge port /8 23 27 Pressure gauge (Option) side gauge port Rc /8 23 27 /4 port /4 7 28 Silencer (Option) 4 x ø5.5 70 EXH port /4 (When silencer installed: 07) (When high-noise reduction silencer installed: 26) /4 port /4 4 x ø5.5 7 28 70 Silencer (Option) EXH port /4 (When silencer installed: 07) (When high-noise reduction silencer installed: 26) 76 43 46 port 4 x ø2 2 28 22 22 5 98 EXH port 8 (When silencer installed: 53.5) (When high-noise reduction silencer installed: 79) 43 With elbow silencer (Option) 3 3 23 27 23 27 /4 port /4 4 x ø5.5 /4 port /4 4 x ø5.5 Silencer (Option) 24 Elbow silencer (Option) 7 28 70 (97) EXH port /4 With elbow silencer (Option) Elbow silencer (Option) 7 28 70 (97) EXH port /4 22 22 ARJ AR425 to 935 ARX AMR ARM ARP IR-A IR IRV VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00 25 62.8 62 /2 port /2 22 8 Silencer (Option) 96 6 3.2 4 x ø2 30 EXH port /2 (When silencer installed: ) (When high-noise reduction silencer installed: 230) 09

Series Dimensions 22A-03 IN side gauge port /8 300 39 Pressure gauge (Option) side gauge port /8 59 28 Pilot port /8 39 43 46 port 2 5 Silencer (Option) 24 42A-04 IN side gauge port /8 53 73 3.2 404 40 Pressure gauge (Option) side gauge port /8 4 x ø2 98 8 EXH port (When silencer installed: 53.5) (When high-noise reduction silencer installed: 79) 85 43 Pilot port /8 /2 72 62 62.8 port /2 22 8 Silencer (Option) 43A-04 IN side gauge port /8 96 6 404 40 3.2 Pressure gauge (Option) side gauge port /8 4 x ø2 30 EXH port /2 (When silencer installed: ) (When high-noise reduction silencer installed: 230) 43 22 /2 62 62.8 port /2 22 8 Silencer (Option) 96 6 3.2 4 x ø2 30 EXH port /2 (When silencer installed: ) (When high-noise reduction silencer installed: 230) Made to Order For detailed dimensions, specifications and lead times, please contact SM. opper-free/fluorine-free 2 E explosion-proof directive (ATEX) compliant 3 Ozone resistant The inner or outer copper parts material has been changed to stainless steel or aluminum. The fluorine resin parts has been changed to general resin. 20 Standard model no. 56 Made to Order opper-free/fluorine-free For booster regulator with pressure gauge, please consult SM. This option cannot be selected for air tank with safety valve. 020 Standard model no. Made to Order E explosion-proof directive (ATEX): ategory 3GD Ozone resistance is strengthened through the use of fluororubber (diaphragm) and hydrogenated NBR (valve, rod seal) for the rubber parts of the seal material. 80 Standard model no. Made to Order Ozone resistant Weather resistant NBR (diaphragm) and hydrogenated NBR (valve) are used for the rubber parts of the standard model.

ARJ AR425 to 935 ARX AMR ARM ARP IR-A IR IRV VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00 02

Air Tank T Series How to Order RoHS Except the hinese pressure vessel regulations compliant product (-X04) Made to Order (For details, refer to page 024.) ompact connections are possible with booster regulators. It can be used alone as a tank. Also partially compatible with overseas standards T05A T20S T0S T38A aution When used as a single unit (not connected with a booster regulator) and pressurized at over MPa at normal temperatures, the air tank falls under the scope of the High Pressure Gas Safety Act in Japan. T 0 A Material Symbol Material A arbon steel (SS400) S Stainless steel 304 Tank internal capacity Symbol Internal capacity 05 5 L 0 0 L 20 20 L 38 38 L Symbol A Standard Product (For Japanese Market) Tank internal capacity Symbol Internal capacity 05 5 L 0 0 L 20 20 L 38 38 L E ertified Product T 0 A F Material Material arbon steel (SS400) S Note) The thread type for each port is Rc. Option Symbol Nil V Option None Drain valve Option Symbol Option Applicable model Nil None Note) All models R Safety valve T05A, T0A (Set pressure: MPa) T20A, T38A S Safety valve T05A (Set pressure: 2 MPa) T0A Note) A safety valve port is provided only when option R or S is selected. SV Q E certified product (Self-declaration document attached) Accessories Symbol Accessories Safety valve (Set pressure: MPa) RV Drain valve Safety valve (Set pressure: 2 MPa) SV Drain valve Thread type Symbol Nil F Thread type Rc G Applicable model T20A T38A T05A T0A 022

Air Tank T Series hinese Pressure Vessel Regulations ompliant Product Tank capacity Symbol Internal capacity 05 5 L 0 0 L 20 22 L 38 38 L Material Symbol Material A arbon steel (SA-44) S Stainless steel (SA-240 36) Tank capacity Symbol Internal capacity 05 5 L 0 0 L 20 22 L, 20 L 38 38 L ASME Standards ompliant Product T 05 Thread type Symbol Thread type Nil Rc N NPT T 05 A Material Symbol Material Exportable models 5L 0L 20L 38L A arbon steel S Stainless steel * * Not applicable to the 38 L type List of Air Tank for Overseas Option Symbol Option Nil None V Drain valve U A N E V X05 ASME standards compliant product Note) The labels indicating compliance with ASME standards are not based on the International System of Units. Therefore, these products cannot be used in Japan under the new Measurement Act. Additionally, these products will be sold by SM orporation of America. Please contact SM for ordering procedures and lead times. Safety valve/set pressure: 2 MPa (Accessory) Note) E: Safety valve is included. X04 hinese pressure vessel regulations compliant product Safety valve/pressure gauge set Note) Symbol Applicable model T05A, T0A U T05S, T0S T20A, T38A T T20S Note) When a drain valve is required, please order it separately. Drain valve part no.: T-V Note) The safety valve/pressure gauge set is not RoHS compliant. Product Not Applicable to the ASME Standard T 05 A N Tank internal capacity Symbol Internal capacity 05 5 L 0 0 L Material Symbol Material A arbon steel (SS400) Thread type Symbol Thread type Nil Rc N NPT Note) SV Note) This product is for overseas use only according to the new Measurement Law. (The SI unit type is provided for use in Japan.) X Product not applicable to the ASME standard Option Symbol Option Nil None Note ) V Drain valve Note ) Safety valve Note 2) S (Set pressure: 2 MPa) Safety valve Note 2) SV (Set pressure: 2 MPa) Drain valve Note ) ustomers are responsible for preparing a safety valve. Note 2) Safety valve does not meet ASME specifications. ARJ AR425 to 935 ARX AMR ARM ARP IR-A IR IRV VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00 ountry/region Law Exportable models Details T05A-X0 Note 2) T0A-X0 T20A-X0 South Korea. Industrial Safety and Health Act T38A-X0 K ertification 2. High-Pressure Gas Safety ontrol Act T05S-X0 T0S-X0 T20S-X0 T38S-X0 Thailand, Taiwan No applicable standard Standard product. K ertification compliant product (ertificate included) 2. High-pressure Gas Act not applicable (Not applicable when maximum operating pressure: 0.97 MPa) Option (Order it separately.) T-K Note ) (Safety valve) T-V (Drain valve) Note ) T-K is not RoHS compliant. Note 2) This is exempt from the revision of Korean pressure vessel act (enforced in March, ). (Exception conditions: The inside diameter of the body is mm or less.) Therefore, the K ertification nameplate is not attached to the T05A-X0. The T-R safety valve can be used. 023 D

T Series Standard Product (For Japanese Market) Specifications Model T05 T0 T20 T38 ompressed air Fluid Tank capacity (L) Max. operating pressure (MPa) TA TS size port size Ambient and fluid temperature ( ) Installation TA Weight (kg) TS TA Material TS TA Paint TS 5 0 20 2.0.0 2.0 /2 /2 /2 0 to 75 Horizontal (Floor mounting) 6.6 0 4 3.2 4.9 2 arbon steel (SS400) Stainless steel 304 Outside: Silver paint, Inside: Rustproof paint None Note ) The accessories and options are included in the same container. Note 2) Since neither copper nor fluorine parts are used for the tank, the standard model can be used as a copper-free product when drain valve is not necessary. Options/Accessories/Part No. <For TA (arbon Steel)> Model T05A- T0A- T20A- T38A- Accessory kit T5A-Y-3 T0A-Y-3 T20A-Y-3 Safety valve (When selecting an option) Note ) 2) T-R (Set pressure: MPa), T-S (Set pressure: 2 MPa) T-R (Set pressure: MPa) Drain valve (When selecting an option) T-V Note ) The set pressure of the safety valve cannot be changed. Note 2) The safety valve is a safety measure that protects the tank from excess pressure. The valve opens automatically when the specified pressure is reached, releasing excess pressure inside the tank. The valve closes again when the pressure drops below a designated value. Select a pressure valve appropriate for the maximum operating pressure specification of the tank. <For TS (Stainless Steel)> Model T05S- T0S- T20S- T38S- Accessory kit T5S-Y-4 T0S-Y-4 T20S-Y-4 Drain valve (When selecting an option) T-V The Accessory Kit is a Set of Nos. q to r. Safety valve Drain valve: T-V Model T5A-Y-3 T0A-Y-3 T20A-Y-3 No. T5S-Y-4 T0S-Y-4 T20S-Y-4 R/4 Description Quantity (A) q O-ring (2A) Hexagon socket head taper w port screwed plug (for drain port) Rc/8 9 Hexagon socket 4 (A) e 4 4 head cap screw 4 (2A) Drain valve r Anchor bolt/nut 4 ø30 For detailed dimensions, Body material: Brass Made to Order specifications and lead Safety valve mounting diagram Safety valve: T-R, T-S when there is no safety valve port times, please contact SM. Tank port ø8.5 Safety valve opper-free/fluorine-free T-V2 (A set of stainless steel needle valve and fittings) is included with the standard product. 20 T 0 A V Made to Order Tank internal Drain valve/ opper-free/fluorine-free capacity T-V2 Symbol Internal capacity Material 05 5 L Symbol Material 0 0 L A arbon steel (SS400) 20 20 L S Stainless steel 38 38 L Note ) The thread type for each port is Rc. Note 2) Stainless steel fittings and a needle valve are included in the same container as accessories. (For lead times and detailed dimensions, please contact SM.) It can be ordered separately. Note 3) Since neither copper nor fluorine parts are used for the tank, the standard model can be used as a copper-free product when drain valve is not necessary. Note 4) The material of the safety valve is brass only. 024 52 65 22 (Width across flats 9) Body material: Brass 58 (LOSE) to 63 (OPEN) Union tee () Fitting Mounting diagram for drain valve T-V2 (A set of stainless steel needle valve and fittings is included.) Needle valve 38 3/4 2 9 Fittings Body material: Stainless steel 20 When the tank port is, use fittings. When the size of the tank port is other than, change the size with a union tee fitting.

Air Tank T Series Dimensions: Standard Product (For Japanese Market) T05A Material: arbon steel onnected to 0A, A Tank port Rc /2 Tank port Rc T0A Material: arbon steel onnected to 0A, A onnected to 20A Tank port Rc /2 305 80 Tank port Rc /2 32 4 47 Rc T20A Material: arbon steel onnected to 20A, 40A Rc /2 70 Rc /2 278 338 349 Rc /4 Rc /2 32 4 47 (454) (367) Rc Rc /2 63 Booster regulator Rc ø80 257 Rc /4 Rc Rc /2 70 Booster regulator ø206 278 Rc /4 20 80 (370) (307) (39) (8) EXH: Rc 4 x ø EXH: 4 x ø3 Booster regulator Rc /4 ø56 Booster regulator Rc /4 ø80 (47) (367) 00 20 80 Rc ø80 ø206 EXH: Rc /4 4 x ø The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. EXH: Rc /4 4 x ø The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. onnected to 22A 20 80 EXH: Rc 4 x ø EXH: 4 x ø3 D 442 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. onnected to 22A, 42A ARJ AR425 to 935 ARX AMR ARM ARP IR-A IR IRV VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00 400 674 685 Rc /4 00 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. 00 (mm) Booster regulator model A B D Note) 20A 48 394 Rc 40A 520 429.8 Rc /2 22A 444 394 Rc 469 42A 477 429.8 Rc /2 493 Note) When option G (pressure gauge) is selected 025

T Series Dimensions: Standard Product (For Japanese Market) T38A Material: arbon steel onnected to 20A, 40A 355 205 Tank port Rc 3/4 0 824 835 Rc /2 Rc /2 Rc /4 2 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. ø256 EXH: 4 x ø3 Booster regulator model 20A 40A 22A 42A onnected to 22A, 42A ø256 A 53 570 494 527 2 B 444 479.8 444 479.8 EXH: 4 x ø3 Rc Rc /2 Rc Rc /2 Note) When option G (pressure gauge) is selected D (mm) D Note) 59 543 T05S Material: Stainless steel 304 onnected to 0A, A Tank port Rc Rc 63 257 (370) (307) Booster regulator Rc /4 ø EXH: Rc /4 4 x ø Rc /4 300 00 T0S Material: Stainless steel 304 onnected to 0A, A Rc Booster regulator Rc /4 EXH: Rc /4 Tank port Rc /2 70 278 (39) (8) ø80 4 x ø Rc /4 32 4 20 80 onnected to 20A Rc Booster regulator Rc onnected to 22A Rc Tank port Rc /2 70 278 (454) (367) ø80 EXH: Rc 4 x ø (47) (367) ø80 EXH: Rc 4 x ø 442 026 32 Rc /4 20 80 20 80

Air Tank T Series Dimensions: Standard Product (For Japanese Market) T20S Material: Stainless steel 304 onnected to 20A, 40A, 43A onnected to 22A, 42A Tank port Rc /2 305 80 Rc /2 Booster regulator ø206 EXH: 4 x ø3 ø206 EXH: 4 x ø3 D ARJ AR425 to 935 ARX AMR Rc /4 400 674 00 Booster regulator model 20A 40A 22A 42A 43A 00 A 48 520 444 477 526 B 394 429.8 394 429.8 429.8 Rc Rc /2 Rc Rc /2 Rc /2 Note) When option G (pressure gauge) is selected (mm) D Note) 469 493 ARM ARP IR-A IR IRV T38S Material: Stainless steel 304 onnected to 20A, 40A, 43A 355 205 Tank port Rc 3/4 0 824 Rc /2 Rc /4 Booster regulator ø256 2 EXH: 4 x ø3 onnected to 22A, 42A ø256 Booster regulator model 20A 40A 22A 42A 43A 2 A 53 570 494 527 576 B 444 479.8 444 479.8 479.8 EXH: D 4 x ø3 Rc Rc /2 Rc Rc /2 Rc /2 Note) When option G (pressure gauge) is selected (mm) D Note) 59 543 VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00 05 R T A- S T A- 0 With safety valve 20 R 38 S With safety valve Safety valve port Rc A Tank model T05 T0 (mm) A 30 2 Safety valve port Rc 027

T Series E Marking-onformity Products Specifications Model T05A-SV-Q T0A-SV-Q T20A-RV-Q T38A-RV-Q Fluid ompressed air Tank capacity (L) 5 0 20 38 Max. operating pressure (MPa) 2.0.0 size /2 3/4 port size /2 /2 3/4 Ambient and fluid temperature ( ) 0 to 75 Installation Horizontal (Floor mounting) Weight (kg) 6.6 0 4 2 Material arbon steel (SS400) Paint Outside: Silver paint, Inside: Rustproof paint Note) Accessories are included in the same container. Accessories/Part No. <E Marking-onformity Products> Model T05A-SV-Q T0A-SV-Q T20A-RV-Q T38A-RV-Q T5A-Y-2 T0A-Y-2 Accessory kit Safety valve Drain valve T-S (Set pressure: 2 MPa) The Accessory Kit is a Set of Nos. q to t. No. Model T5A-Y-2 Description q Bushing assembly (with O-ring) w Hexagon socket head taper screwed plug (for drain port) e Hexagon socket head cap screw 4 r Anchor bolt/nut t Hexagon socket head taper screwed plug (for safety valve port) T0A-Y-2 Quantity 4 (A) 4 (2A) T-V T20A-Y-2 4 4 T20A-Y-2 T-R (Set pressure: MPa) Safety valve Drain valve: T-V R/4 Safety valve: T-R, T-S ø8.5 Drain valve 58 (LOSE) to 63 (OPEN) ø30 9 20 port Rc/8 52 65 22 (Width across flats 9) Body material: Brass Body material: Brass 028

Air Tank T Series Dimensions: E Marking-onformity Products T05A-Q Material: arbon steel onnected to 0A, A Safety valve port /2 Booster regulator 2 x /2 EXH: Tank port /2 Tank port /4 30 Safety valve port 30 338 3 70 278 63 32 4 482 2 x /2 (454) 257 70 (367) 278 ø80 (370) (307) (39) (8) Booster regulator /4 ø56 Booster regulator /4 4 x ø 00 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. T0A-Q Material: arbon steel onnected to 0A, A Tank port /2 /4 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. onnected to 20A Safety valve port /2 2 x /2 ø80 20 80 (47) (367) EXH: /4 4 x ø EXH: /4 4 x ø onnected to 22A ø80 EXH: 4 x ø 442 ARJ AR425 to 935 ARX AMR ARM ARP IR-A IR IRV VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00 32 4 482 /4 20 80 20 80 When option G (pressure gauge) is selected The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. 029

T Series Dimensions: E Marking-onformity Products T20A-Q Material: arbon steel onnected to 20A, 40A 3/4 Safety valve port Booster regulator onnected to 22A, 42A 305 80 Tank port /2 2 /4 400 674 696 2 x /2 The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. ø206 00 EXH: 4 x ø3 Booster regulator model 20A 40A 22A 42A ø206 A 48 520 444 477 00 B 394 429.8 394 429.8 /2 /2 EXH: Note) When option G (pressure gauge) is selected D 4 x ø3 (mm) D Note) 469 493 T38A-Q Material: arbon steel onnected to 20A, 40A 355 205 Tank port 3/4 3/4 Safety valve port 2 x /2 2 /4 0 824 846 Booster regulator The length may be longer than the specification if the plugs mounted on the tank are not fit to the end. The length of G thread type is about 6 mm longer due to plug type differences. ø256 2 EXH: 4 x ø3 Booster regulator model 20A 40A 22A 42A onnected to 22A, 42A ø256 A 53 570 494 527 2 B 444 479.8 444 479.8 /2 /2 EXH: Note) When option G (pressure gauge) is selected D 4 x ø3 (mm) D Note) 59 543 030

T Series ASME Standards ompliant Product Specifications Model T05A/T05S T0A/T0S T20A/T20S T38A/T38S Fluid ompressed air Tank capacity [L] 5 0 22 38 Max. operating pressure [MPa] 2.0 size /2 port size /2 /2 3/4 Ambient and fluid temperature [ ] 0 to 75 Mounting Horizontal (annot be mounted to walls or ceilings.) Weight [kg] 4.5/3.2 9./8.2 5.0/3.2 20.9/20.4 Material TA arbon steel SA-44 (Plug for inspection port is made of carbon steel.) TS Stainless steel SA-240 36 (Plug for inspection port is made of stainless steel.) Paint TA Outside: Silver gray, Inside: Phosphate coated treatment Surface treatment TS Outside: Acid cleaning Note) Documents included Manufacturer s certificate of compliance Operation manual Included parts Safety valve Accessory kit Note) Scratches, scrapes, blotches, and uneven color may be present on the surface, but they do not affect the function or performance of the product. Options/Accessory Numbers TA(arbon steel) Model T05AN T0AN T20AN T38AN T05A T0A T20A T38A Thread type NPT Rc Accessory kit T5A-Y-3N T0A-Y-3N T20A-Y-3N T5A-Y-3 T0A-Y-3 T20A-Y-3 Safety valve T-EN T-E Drain valve T-VN T-V TS(Stainless steel) Model T05SN T0SN T20SN T38SN T05S T0S T20S T38S Thread type NPT Rc Accessory kit T5S-Y-4N T0S-Y-4N T20S-Y-4N T5S-Y-4 T0S-Y-4 T20S-Y-4 Safety valve T-EN T-E Drain valve T-VN T-V The accessory kit is a set of nos. q to r. Model T5A-Y-3N T0A-Y-3N T20A-Y-3N T5S-Y-4N T0S-Y-4N T20S-Y-4N No. T5A-Y-3 T0A-Y-3 T20A-Y-3 T5S-Y-4 T0S-Y-4 T20S-Y-4 Description Quantity q O-ring (A) (2A) w Hexagon socket head taper screwed plug (For drain port) e Hexagon socket head cap screw 4 4 (A) 4 (2A) 4 r Anchor bolt/nut 4 Keep the manufacturer s certificate of compliance in a safe place. B 030-

Air Tank T Series Dimensions T05AN-E-X05/T05A-E-X05 T05SN-E-X05/T05S-E-X05 Safety valve (Supplied with product) Safety valve port /4" Inspection port 3/4" (With plug) " Tank port " Inspection port 3/4" (With plug) 63 257 Drain valve (Option) 352 374 /4" Safety valve (Supplied with product) Safety valve port /4" Inspection port 3/4" (With plug) Safety valve (Supplied with product) onnected to 0A, A Safety valve port /4" Inspection port 3/4" (With plug) " Tank port /2" 70 278 Inspection port 3/4" (With plug) " Tank port /2" Inspection port 3/4" (With plug) (370) (307) (39) (8) T05A(N)-E-X05 /4" ø /4" ø70 00 20 80 EXH: /4" 4 x ø * Order the booster regulator separately. * The length may be longer than the specification if the plugs mounted on the tank are not tightly fitted to the ends. T0AN-E-X05/T0A-E-X05 T0SN-E-X05/T0S-E-X05 /4" onnected to 0A, A 32 498 522 onnected to 20A Drain valve (Option) 70 278 (454) (367) " ø70 EXH: /4" 4 x ø EXH: " (370) (47) (307) (367) T05S(N)-E-X05 /4" ø48 00 EXH: /4" 4 x ø onnected to 22A " ø70 EXH: " 4 x ø 4 x ø (442) ARJ AR425 to 935 ARX AMR ARM ARP IR-A IR IRV VEX SRH SRP SRF ITV I ITVH ITVX PVQ VY T AP00 /4" 32 498 522 Drain valve (Option) 20 80 20 80 * Order the booster regulator separately. * The length may be longer than the specification if the plugs mounted on the tank are not tightly fitted to the ends. 030-2 A