Series BLK Oil - air cooler

Similar documents
Change-Over Pressure Filter DFDK

Displacement 12, , Maximum flow rate (at 1450 rpm) bar.

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

P2* MODULAR SUBPLATES FOR ISO (CETOP 03) VALVES

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

HIGH PRESSURE FILTERS DFDK Series Inline Duplex Filters 4568 psi up to 90 gpm

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Instruction Manual Contact Pressure Vacuum Gauge

Prop. 3-Way Pressure-Reducing Cart., Size 5 / SAE 08

ASM. Asynchronous Spindle Motors. SEM Limited Faraday Way Orpington, Kent BR5 3QT United Kingdom

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

hyprofiltration.com/fsw

PRESSURE SEQUENCE VALVE TYPE UZK

Instruction Manual Differential Pressure Transmitter

LMP Filter element in according to DIN Style B. Style S. Maximum pressure 30 bar F l o w r a t e s t o l / m i n D.I. D.I.

Directional Controls

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

Pressure reducing valve, direct operated

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

Pressure reducing valve, direct operated, type DR 5 DP Huade América 1

BW0500AO. ByWire Elements BW0500AO Element 4/3 with side ports IBW0500 Interface

L6090 (LC04M-CBL) - L6095 (LC04M-CBD)

Axial piston pumps type PVPY-C (-R, -L) variable displacement, with mechanical controls obsolete components - availability on request

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

Flow Control Valves. 1 Description. 2 Symbols. Series MTKA, MTQA, MTCA 2.1 MTKA MTQA flow control valve. 1.1 MTKA flow control valve

Fixed Displacement Motor A4FM

D62 - D63 Directional Control Valve l/min

3-Way Safety Block DSV

Proportional Pressure-Relief Cartridge Valve, Size 2...4

WK /2 WAY CARTRIDGE VALVE TYPE URZS 32 COVER FOR CARTRIDGE VALVE TYPE ULZS 32. Size 32 up to 42 MPa 700 dm 3 /min DESCRIPTION OF OPERATION

Check Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.

SPC*01 (2-way) SPC03/06 (2-way) Size NG6 NG10 NG16 NG25 DIN A10 ISO 4401 NFPA D05 CETOP 5 P, A, B:

D e s c r i p t i o n

E 158 E 198 E 248. Tank top mounting Connection up to G11 / 4 Nominal flow rate up to 250 l/min e d

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DENISON HYDRAULICS vane pumps - single, double T6G - T67G - T6ZC

Two-stage valve type NE

3-Way Pressure-Reducing Cartridge, Size 2 4

4/2 way Pneumatic Solenoid Valve

Electrically Operated Pressure-Relief Cartridge, Size 10

Workshop Compressors CLASSIC Series

E 094 E 103 E 143 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 135 l/min / 35.7 gpm

Inverse Prop. Pressure-Relief Cart., Size 2 4

Instruction Manual Contact Pressure Gauge

Hand pump type CH. Product documentation. 300 bar 8.3 cm 3 /stroke. Operating pressure p max : Displacement volume V max stroke :

Vickers. Filters. Reservoir Vent Filters. Spin-on Air Filters & Adaptors. Rev. 3/98

3-way control valves VK 3

Fixed Displacement Pump KFA for commercial vehicles in open circuits

Mobile High Pressure Compressor Unit for Compressing Air and Breathing Air. PE 250-TE with compressor control (optional equipment)

Seated valves VRB 3, VRG 3

INVERS. Solenoid coil 24VDC 12 VDC Exm Exd Explosion protection marking:

Instruction Manual Differential Pressure Transmitter

Centriflow Plus High-pressure plug fan - Technical Data

Series 44 Self-operated Pressure Regulators. Type 44-0 B Pressure Reducing Valve. ANSI version

Two-port valves, male threaded, PN25

Pressure reducing valve, pilot operated, Model 3DR

Suction fi lters. SF2 500 series. Flow rate up to 800 l/min. Suction fi lters

HNP-021 Oil Purifier. Description. Specifications. Features. Contact Us:

Inverse Proportional Pressure-Relief Cart., Size 2 4

Axial piston pumps type PVC

PVQ 13 A2 R SE 1 S 20 C-11 D

Axial piston pumps type PVC

Inverse Proportional Pressure-Relief Cartridge, Size 10

Series 44 Self-operated Pressure Regulators. Type 44-1 B Pressure Reducing Valve. Type 44-6 B Excess Pressure Valve. ANSI version

Pressure transmitters EMP 2

Monoblock directional control valves ML - Directional control valve

E 212 E 222 Tank top mounting Connection up to G1¼ / -20 SAE Nominal flow rate up to 220 l/min / 58.1 gpm

Solenoid valve type EVR for Hydrocarbons

2-way flow control valve Model 2FRM 6

Fixed Displacement Plug-In Motor A2FE

D 042 D 062 In-line mounting Operating pressure up to 100 bar Nominal flow rate up to 90 l/min

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Cooler-Bypass Thermostat Valve, Size 16

4/3 Directional valve elements L85L1...(EDC-LV) with manual lever operated control with flow sharing control (LUDV concept) L85L1...

Electromechanical pressure switches

Fixed Displacement Motor A4FM

2-Port Seat Valves with Flange, PN 16

Pressure reducing valve, direct operated, sandwich plate, type ZDR6D...40B/(New Series)

E 441 E 451 E 461 E 641 E 700 Tank mounting Nominal flow rate up to 800 l/min

Technical information

Pressure relief valves

Product Range. Compressors Purification Storage Filling Panels Nitrox/Trimix. High Pressure Solutions from L&W!

FIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:

Inverse Proportional Pressure-Relief Cart., Size 2 4

50Hz. water solutions. O SerieS DGO DRO

Directional Control Valves Technical Information Model 1500

Pneumatic spool valve islands

GA24 Technical Datasheet

Pneumatic valve islands

Tightness controls TC 1 3 and TC 4

2-Port Seat Valves with Flange, PN 16

Safety relief valves, type BSV 8 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Monoblock Directional Control Valve RMB 202

Solenoid gas valve. The solenoid gas valve is also applicable as a main gas valve Pilot gas valve for forced draft burners

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Pressure reducing valve, direct operated

APPLICATION. Conveyors Metal working machines Machines for agriculture Road building machines Mining machinery Food industries

Tightness control TC. Product brochure GB 3 Edition AGA

Transcription:

Series BLK Oil - air cooler maintenance friendly design broad performance range compact dimensions rugged cooling matrix low noise emissions comprehensive accessories DE 35 0001 04/2004 Bühler Meß- und Regeltechnik GmbH D - 40880 Ratingen, Harkortstr. 29 Tel.: + 49 (0) 2102 / 49 89-0 Fax: + 49 (0) 2102 / 4989-20 e-mail: fluidcontrol@buehler-ratingen.com

2 Why coolers? There are basically two main concepts in the development of fluid power systems. One is to design systems without any cooler and if the operational conditions show in practice that the system needs a cooler to install it later. This however requires compromises that usually result in financial overspend. The other concept recognises that a system originally designed with an integrated cooler can be designed more compactly, needs less installation space and runs more reliably due to the stabilized temperature of the fluid. Why Bühler? Todays requirements for an oil/air cooler demand for an effective and compact design with low noise emission and very easy maintenance. The development of the new BLK series is based on over 30 years of experience in design and sales of air/oilcoolers. In particular the fatigue life of the cooling matrix was highlighted in the development as the matrix has to withstand pressure peaks in the return line. Due to the exposure to the various ambient conditions air/oil cooler matrixes inevitably require some maintenance. Therefore the cooling matrix can be easily separated from the fan case without the need to dismantle the ventilator or motor or any other parts. If our comprehensive standard range of products does not have an answer for your application we will be pleased to find special solutions for your application. The data contained in this leaflet is sufficient to determine the right cooler for your application. However, we can offer you a computer program which makes this sizing easier for you. BNF, BKF Description The BLK series consist of the following components: cooler matrix fan case with mounting feet fan motor assembly consisting of AC motor, fan and finger guard The cooling matrix and fan can be separated from the fan case individually without the need to dismantle other components. The cooling matrix of the BLK series is made from aluminium. The matrix is suitable for use with hydraulic fluids (also return lines) but is not suitable for clean water or water based fluids. The cooling matrix can be equipped with by-pass valves of different configurations (see type code). Please pay attention to the chapter installation. Depending on the application or due to system requirements, off line filtration is often the appropriate solution. We recommend in these cases that you combine this off line circuit with an off line cooler. Suitable units can be found in our BNK series. These units are also suitable for the upgrade of existing systems. BNK

3 Sizing the right cooler The determination of a cooler follows two steps: - determination of cooler size - determination of expected pressure loss Nomen clature töe [ C] tle [ C] inlet oil temperature inlet air temperature ETD [K] temperature differential: ETD = töe - tle Pspez [kw / K] specific cooling performance (see performance curves) P spez =P/ETD P [kw] Q [l/min] CÖl [kj/kgk] cooling performance in kw oil flow rate specific heat capacity of oil (approx. 2,0 kj / kgk) [kg/dm³] specific gravity of oil 0,9 kg/dm³ Calculation sample: assumptions: tank capacity start up temperature of oil The oil is heated up approx. ( V) ( T1) ca. 200 l 15 C 25 minutes to required oil temperature inlet air temperature oil flow rate ( T2) ( t ÖE) ( tle) ( Q) 45 C 60 C 30 C 80 l/min Pressure loss curves determined with an average viscosity of 30 cst Dp/ bar 3 2,5 2 1,5 1 0,5 0 BLK 2 BLK 1 BLK 3 BLK 4 BLK 6 BLK 5 BLK 8 BLK 7 BLK 9 BLK 10 0 50 100 150 200 250 300 350 400 Q l/min Attention: If the coolers are used in open air or the oil has even higher viscosity the installation of by-pass valves may be necessary. Please check the section functions schemes. Calculation 1. calculation of P P= 2. ETD=t -t =60 C -30 C =30K ÖE LE 3. required specific performance: P = P / ETD = 7,2 kw / 30 K = 0,24 kw/k spez 200 x 0,9 x 2,0 x (45-15) 25x60 4. choose in curve at 80 l/min a cooler with: Pspez 0,24 kw/k: There are two possibility s: BLK 2.2 or alternativly BLK 3.4 this cooler is larger but has the lower noise emission Temperature/viscosity table Type of oil at 50 C at 60 C at 70 C VG 16 9,4 5,6 3,3 cst VG 22 15 11 8 cst VG 32 21 15 11 cst VG 46 29 20 14 cst VG 68 43 29 20 cst VG 120 68 44 31 cst VG 220 126 77 51 cst VG 320 180 108 69 cst Correction factor k(visc) =7,2 kw viscosity (cst) k(visc) viscosity (cst) k(visc) 10 0,6 60 1,6 20 0,8 80 2,1 30 1,0 100 2,7 40 1,2 150 4,2 50 1,4 Determine of real pressure loss: 1. select in graph the Dp at Q of a choosen cooler type 2. determine real viscosity from temperature/viscosity table 3. take correction factor k(visc) according to real viscosity and multiply with Dp in bar

4 Performance curves BLK size 1 to 6 kw / K 1,2 1,1 BLK 6-4 1,0 0,9 0,8 BLK 6-6 0,7 0,6 BLK 5-4 0,5 0,4 BLK 3-2 BLK 4-4 BLK 5-6 0,3 0,2 0,1 BLK 1-2 BLK 2-2 BLK 2-4 BLK 3-4 BLK 4-6 0,0 0 50 100 150 200 250 Q l/min Performance curves BLK size 7 to 10 kw / K 3,4 3,2 BLK 10-6 3,0 2,8 BLK 10-8 2,6 2,4 2,2 2,0 BLK 9-6 1,8 1,6 1,4 BLK 8-6 BLK 9-8 1,2 BLK 7-4 BLK 8-8 1,0 0,8 BLK 7-6 0,6 0,4 0,2 0,0 50 100 150 200 250 300 350 400 450 Q l/min

5 General data material / surface protection cooling matrix: aluminium, varnished fan case, finger guard and motor console: mild steel powder coated colour RAL 7001 fluids mineral oil according to DIN 51524 oil/water emulsion HFA and HFB according to CETOP RP 77 H water glycol HFC according to CETOP RF 77 H phosphate ester HFD-R according to CETOP RP 77 H Basic datas Operating pressure static: max. 21 bar operating temperature media: max.120 C max. viscosity 100 cst average viscosity, higher viscosities upon request electrical motors: (others on demand): voltage: BLK 1.2 230 V 50Hz BLK 2.2 - BLK 10.8 230 / 400 V 50Hz ± 5% 276 / 480 V 60Hz ± 5% insulation class: F rise in temperature: B protection class: IP 55 design according to: IEC 34-1, IEC 72-1, DIN 57530, VDE 0530 part no. type motor full load current motor weight (kg) volume (l) noise emission power output at 400V poles db(a)* 3501200 BLK 1.2 0,25 kw / 0,24A 230V 2 7 0,8 65 3502200 BLK 2.2 0,55 kw / 1,54 A 2 23 1,3 81 3502400 BLK 2.4 0,25 kw / 0,94 A 4 23 1,3 66 3503200 BLK 3.2 1,1 kw / 2,64 A 2 31 1,8 87 3503400 BLK 3.4 0,25 kw / 0,94 A 4 28 1,8 71 3504400 BLK 4.4 0,37 kw / 1,12 A 4 34 2,3 73 3504600 BLK 4.6 0,18 kw / 0,80 A 6 34 2,3 63 3505400 BLK 5.4 0,75 kw / 1,99 A 4 45 3,1 79 3505600 BLK 5.6 0,25 kw / 1,09 A 6 42 3,1 68 3506410 BLK 6.4 2,2 kw / 5,12 A 4 77 4,1 86 3506610 BLK 6.6 0,55 kw / 1,85 A 6 60 4,1 74 3507410 BLK 7.4 2,2 kw / 5,12 A 4 87 5,4 89 3507610 BLK 7.6 0,55 kw / 1,85 A 6 72 5,4 75 3508610 BLK 8.6 1,5 kw / 3,88 A 6 95 6,3 79 3508810 BLK 8.8 0,55 kw / 2,10 A 8 91 6,3 73 3509610 BLK 9.6 2,2 kw / 5,48 A 6 159 8,2 86 3509810 BLK 9.8 1,1 kw / 3,52 A 8 155 8,2 79 3510610 BLK 10.6 5,5 kw / 12,60 A 6 256 19 90 3510810 BLK 10.8 2,2 kw / 6,05 A 8 241 19 84 The part numbers for BLK 2-5 are 50/60 Hz versions, for BLK 6-10 the 50 cycle versions only, the 60 cycle versions are available upon request. * DIN EN ISO 3744, class 3 Type code BLK 4. 6- IBx - T50 number of poles (see table 1) size (see table 1) BLK 4. 6- IBx - T50 If the by-pass valve or if the temperature switch are needed the following codes have to be added: by-pass version AB IB ITB ATB x external by-pass integrated by-pass integrated temperature operated by-pass 2 bar / 45 C external temperature operated by-pass 2 bar / 45 C by-pass pressure 2;5or8bar temperature switch T50,T60 T70,T80 figures stand for C, details see data sheet

6 Dimensions E H M 67** 100* N J B T G *** MB 30 **** ØK (4x) L D C 20 F 20 A MB some types have consoles to support motor T connection G ½ for temperature switch connection M14 x1,5 for temperature switch BLK 1 * BLK 9 and 10 = 150 mm ** BLK1=45mm BLK10=94mm *** connection only at BLK 9 and 10 **** BLK 1=20mm cooler type A B C D E F G H J K L M N MB BLK 1.2 315 237 190 62,5 144 165 - - 2x G1/2 7 20 50 25 - BLK 2.2 370 370 203 83,5 406 510-25 2x G1 9 33 125 106 - BLK 2.4 370 370 203 83,5 406 510-25 2x G1 9 33 125 106 - BLK 3.2 440 440 203 118,5 431 510 230 25 3x G1 9 33 150 105 - BLK 3.4 440 440 203 118,5 453 510 230 25 3x G1 9 37 150 105 - BLK 4.4 500 500 203 148,5 456 510 230 25 3x G1 9 37 175 104 - BLK 4.6 500 500 203 148,5 456 510 230 25 3x G1 9 37 175 104 - BLK 5.4 580 580 356 112 505 510 305 26,5 3x G1 9 37 200 100 - BLK 5.6 580 580 356 112 483 510 305 26,5 3x G1 9 37 200 100 - BLK 6.4 700 700 356 172 609 510 410 9,5 3x G1 1/4 9 37 225 110 x BLK 6.6 700 700 356 172 530 510 410 9,5 3x G1 1/4 9 37 225 110 x BLK 7.4 700 840 356 172 634 510 590 9,5 3x G1 1/4 9 37 250 91 x BLK 7.6 700 840 356 172 555 510 590 9,5 3x G1 1/4 9 37 250 91 x BLK 8.6 870 870 508 181 643 890 585 11 3x G1 1/4 12 50 275 101,5 x BLK 8.8 870 870 508 181 618 890 585 11 3x G1 1/4 12 50 275 101,5 x BLK 9.6 1010 1020 518 246 699 890 822 3 4x G1 1/2 12 73 300 99 x BLK 9.8 1010 1020 518 246 682 890 822 3 4x G1 1/2 12 73 300 99 x BLK 10.6 1185 1185 600 242,5 836 910 940 5 4x SAE 2 1/2" 12 73 325 130 x BLK 10.8 1185 1185 600 242,5 798 910 940 5 4x SAE 2 1/2" 12 73 325 130 x connection BLK 10 = SAE 2 ½ flange - 3000 psi

7 Function schemes Standard BLK 2 Standard BLK 1/3 to BLK 10 BLK 3-10 BLK 3-10 BLK 9-10 BLK 3-10 Flow direction optional from left to right or vice versa. Flow direction optional from high left to low right or vice versa. Other ports must be plugged. Internal by-pass IB/ITB (BLK 3-10) with by-pass valve B/2 Oil inlet and outlet are always at the same side. Ports on opposite side must be plugged. with temperature operated by-pass valve External by-pass AB/ATB (BLK 2-10) C with temperature switch Oil inlet is always from low port, outlet on opposite side. Other ports must be plugged. C

8 Installation Location The cooler must be located in such a way that the air flowing through the matrix has free flow on entry and exit. The distance between air intake or air outlet to the nearest surrounding obstacle should be a minimum of half the height of the matrix (dimension B). Free air flow must be provided. If the cooler is to be sited near to working personnel the effect of hot draught and noise emissions must be taken into account. If the ambient air is carrying impurities or other particulates the cooling matrix could become clogged quite quickly thus reducing the cooling efficiency. If this situation is unavoidable we recommend cleaning the matrix on a regular basis (see operation manual). Mounting The BLK's are mounted with four bolts through their mounting feet to an adequate support structure. The cooler can be mounted over head or to walls with no restriction. Connection of oil circuit The connections from the cooler to the system should be stress and vibration free. The use of flexible hoses is highly recommended. Please comply with local safety requirements and avoid any risk to the environment from oil spills etc. If the cooler is located in open air the motors must be weather shielded. Always provide good accessability for inspection or maintenance. The series BLK is a product designed by BÜHLER company The company BÜHLER MESS- UND REGELTECHNIK GmbH, Ratingen was founded in 1969. BÜHLER s corporate philosopy is to offer products and solutions representative of the state of the art. BÜHLER also specialises in producing level and temperature measuring equipment, particularly for the fluid power industry. The products Our commitment to customers has given rise to a production program which comprises specialized products for fluid technology. Although these products were initially developed entirely as specials many of them have now become industry standards. Bühler quality Bühler has achieved accreditation from Lloyd s register to be in compliance with ISO 9001 and therefore consider it our obligation to offer our customers not only excellent products, but also the best service possible. We reserve the right to amend specification