Terminal block. D sub-connector

Similar documents
Digital electro-pneumatic regulators Series ER100

2/ Port G1/4

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

VACUUM REGULATORS CONTENTS

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Precision Regulator. Series Model Regulating pressure range Port size Page

Series IRV1000/2000/3000

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Digital Flow Switch. Series PFM7

Pilot Check Valve: Metal Body Type

Multistage Ejector Series ZL

Multistage Ejector Series ZL

Direct Operated Precision Regulator Modular Style. Standard Specifications

[Instruments for vacuum measurement, checking and adjustment] 3

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

EXH. Specifications. Descriptions. Min. working pressure MPa

5.0 MPa Maximum Supply Pressure. New. Stepless control of air pressure proportional to an electrical signal. Series ITVX CAT.

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

INSTALLATION & MAINTENANCE INSTRUCTIONS

Power Valve: Precision Regulator. High precision, large capacity relief regulator

DPS-400 SERIES DPH-100 SERIES

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

Related Products: Auto Drain Valve. Model/Specifications. Model

Series ZL. Multistage Ejector. New models! ZL212 large flow rate type and ZL112 with valve. ZX ZR ZM ZY ZH ZU ZL ZF ZP ZCU

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

MANUAL KPS Pressure Control Valve

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

Slit Valve. XGT Series. Low particle generation. With end lock mechanism. Service life of two million cycles. XLA XL XL Q D- XSA XVD XGT CYV

QBS Electronic Pressure Regulator

Series variation. Silencer. High damping effect and 2 types of materials. Applicable cylinder bore size (mm) Effective sectional area (mm 2 )

1.0. ISE70/71 Series CAT.ES A. MPa/1.6 MPa. 3-Screen Display High-Precision Digital Pressure Switch. Angled display.

Pressure Sensor PSE53#

Series ZFC. Air Suction Filter In-line Type with One-touch Fittings

ALF400 to 900, ALT-5/-9

2/2-Way Proportional Valve (motor-driven)

AMS 2710 PCB pressure sensor module with V output

Booster Regulator/Air Tank

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

G1/8 G1/8. Model 0 bar -0,1 bar -0,2 bar -0,3 bar -0,4 bar -0,5 bar -0,6 bar -0,7 bar -0,8 bar

OWNER S TECHNICAL MANUAL

IR1000-A IR1010-A IR1020-A

Position locking powerful chuck. CKL2-*-HC Series CKL2-40CS-HC CKL2-50CS-HC CKL2-63CS-HC CKL2-80CS-HC Compressed air to

2-Color Display Digital Flow Switch

CKL2 Series. Powerful chuck. Operational stroke length: 5, 6, 8, 10, 12, 16, 20, 23mm. Specifications. Switch specifications

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

Proportional pressure regulators VPPE

SUPER PRECISION AIR RELAYS

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Inverse Prop. Pressure-Relief Cart., Size 2 4

Series AMJ. Drain Separator for Vacuum

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

Design Features. General Description

BS12 Piezoresistive OEM Pressure Sensor

BS12N Piezoresistive OEM Pressure Sensor

Inverse Proportional Pressure-Relief Cartridge, Size 10

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

DPC-30 DPC-100. Reference Manual

Standard Specifications

Installation, operating and maintenance Instructions for Seemag bypass level indicator

SPCH/ Blowing block

Self-priming makes priming unnecessary Exhausts the air inside the suction pipe to suck up liquid. Air operated type.

REASONS FOR THE DEVELOPMENT

Pressure Measurement Single-range transmitters for general applications

Pressure Sensor PSE54#

Compact Manometer. Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

TH-1800-T TRX-700-CNG Converter

SITRANS P measuring instruments for pressure

MPM426W/436W Submersible Level Transmitter

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Proportional Pressure-Relief Cartridge Valve, Size 2...4

Vacuum Saving Valve Series ZP2V How to Order ZP2V A5 03 Connection thread symbol for the pad Male thread connection Symbol Thread Applicable fixed ori

Low torque Metal seal type Rotary joint

Series 10-IRV10/20. Vacuum Regulator C08 IRV C08 IRV 20 A. How to Order. Standard connections. Single sided connections. Accessory w Nil G ZN ZP ZA ZB

Specifications. Construction. 2 port valve/series VHK2 3 port valve/series VHK3. Component Parts. Standard style. Flame resistant style

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

How to Order. Rc NPT 1/8 1/4 3/8 1/2

SUPER PRECISION AIR RELAYS

KTE6000 / KTU6000 Series OEM pressure transmitters for industrial media

Air operated valve. VGA342R Series

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order

Inverse Proportional Pressure-Relief Cart., Size 2 4

RD(H)20/25 Pressure-Reducing Regulator User Manual

High-performance submersible pressure transmitter For level measurement Model LH-10

Pressure Sensor/ PSE57 /PSE300AC Series CAT.ES A. 3-Screen Display Sensor Monitor. 500 VAC <Twice that of the PSE560> Remote Type

Compact Pressure Switch

High-performance submersible pressure transmitter For level measurement Model LH-10

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Compact Pressure Switch

Electro-Pneumatic Converter YT-940 SERIES

Model 4000 Pressure Controller

Electropneumatic Transducer (I/P) Installation, Operation and

Mass Flow Controller (MFC) for Gases

Inverse Proportional Pressure-Relief Cart., Size 2 4

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

Transcription:

Spd Series variation ol method Solenoid valve EVD-1 EVD-3 EVR EV21V EVS2 EVL MEVT Model Electro pneumatic regulator Functions include pressure and error display and direct memory. The 1-bit parallel model has been added to the input signal. Functions include pressure and error display and direct memory. The 1-bit parallel model has been added to the input signal. Larger flow rate than EVD-1. Feedback control with semiconductor pressure sensor and electronic control circuit is used. This electro pneumatic regulator allows continuous and precise control of air pressure by electrical signal. Feedback control with semiconductor pressure sensor and electronic control circuit is used. This electro pneumatic regulator allows continuous and precise control of vacuum pressure by electric signal. Smaller than conventional models. Body takeout cable is used for this pneumatic proportional pilot valve to achieve ultimate convenience and space saving. Compact electro pneumatic regulator for low pressure that enables flexible and highprecision proportional control from kpa to 5 kpa. Reduced wiring thin shape. Ultimate space saving thanks to the manifold. Thin electro pneumatic regulator with higher accuracy and responsivity than conventional mechanisms. Wiring method Terminal block D sub-connector Serial transmission FA connector M5 Port size Input signal Rc1/4 Rc3/8 Push-in φ4 Push-in φ6 to 1 VDC to 5 VDC 4 to 2 ma Parallel 1 bit to 2 ma Variable resistance input 56

Electro pneumatic regulator Series variation -11.3 to kpa Pressure control range to 5 kpa Step response (No load) Max. flow rate (l/min (ANR)) Linearity (% F.S.) Hysteresis (% F.S.) : Optimum : Usable Applications to 1 kpa to 2 kpa to 5 kpa to 9 kpa.1 s or less.2 s or less.6 s or less 2 6 8 1 12 15 4 5 7 8 15 ±.3 or less ±.5 or less ±1.5 or less ±2.5 or less.3 or less.4 or less.5 or less 1. or less Pilot pressure control Tension Push pressure Blow Workpiece suction 512 516 538 551 548 556 564 Page Spd 57

Basic system functions Pneumatic proportional control components attain an output and flow rate proportional to the input voltage or current. The input voltage and output pressure/flow rate must be linearly proportional. To achieve this, the pressure and flow rate are varied with electric signals, and an electric controller enables variable continuous control. When used as a system, the circuit is configured so signals from the host controller are converted to to 1 VDC signals,., by the D/A converter (interface). These signals operate the proportional control valve via the controller, controlling the thrust and speed of each actuator,. When needed, highly accurate control is possible through feedback with sensors. Host controller (PLC) D/A converter Digital electro pneumatic regulator Electro pneumatic regulator Pressure switch Loads System application examples Fluid discharge control Chemical liquid drip prevention control Micro position control Spd EVR EVD EVS2 Pump CKD Air operated valve CKD Auto suck valve Bellows Tank Indexing table EVS2 Fluid pressure control Balancer tension control Grinding force control EVR EVD EVR EVD Air pump oller Regulator for large flow rate Nozzle oller EVR EVD Power supply EVR EVD EVL Solenoid valve Grind stone oller Motor Cylinder 58

Electro pneumatic regulator Applications System application examples Tension control using air brakes Air turbine speed control Applications for fluid pressure feeding Fixing lead frames,. Chip component assembly PPS2 24 VDC Leakage inspection EVR EVD Magnetic tape EVR FSM2 EVR EVD EVD EVR Air brake Resin product Lead frames EVD EVR EVR EVD Chip CMP equipment EVL Air turbine Spd 59

EVD Series Compact, high function, digital control Spd 51 42

EVD Series Output display 3 digit LED display as Spd 511

Spd Specifications Descriptions Working fluid EVD-11-*8 Analog (*.../1/2) Digital electro pneumatic regulator EVD-1 Series JIS symbol EVD- 11-P8 Parallel EVD-15-*8 Analog (*.../1/2) EVD- 15-P8 Parallel EVD-19-*8 Analog (*.../1/2) Clean compressed air (JIS B 8392-1: 212 (ISO 8573-1: 21) [1:3:2] or equivalent) EVD- 19-P8 Parallel Max. working pressure 16 kpa ( 23 psi, 1.6 bar) 7 kpa ( 1 psi, 7 bar) 1 kpa ( 15 psi, 1 bar) Min. working pressure Set pressure +5 kpa ( 7.3 psi) Set pressure +1 kpa ( 15 psi, 1 bar) Proof pressure Inlet 24 kpa ( 35 psi, 2.4 bar) 15 kpa ( 15 psi, 1.5 bar) 15 kpa ( 22 psi, 15 bar) Output side 15 kpa ( 22 psi, 1.5 bar) 75 kpa ( 11 psi, 7.5 bar) 135 kpa ( 2 psi, 13.5 bar) Pressure control range *1 ( psi) to 1 kpa ( 15 psi) ( psi) to 5 kpa ( 73 psi) (. psi) to 9 kpa ( 13 psi) Power supply voltage 24 VDC ± 1% (stabilized power supply with ripple rate 1% or less) Current consumption.15 A or less (.6 A or less rush current when the power is turned ON) to 1 VDC(6.7 kω) to 1 VDC(6.7 kω) to 1 VDC(6.7 kω) Input signal to 5 VDC(1 kω) 1 bit to 5 VDC(1 kω) 1 bit to 5 VDC(1 kω) (input impedance) 4 to 2 madc(25 Ω) 4 to 2 madc(25 Ω) 4 to 2 madc(25 Ω) 1 bit Preset input 8 points None 8 points None 8 points None Output signal Output accuracy: ±6% F.S. or less, analog output: 1 to 5 VDC (connecting load impedance 5 kω and over) *2 Switch output: NPN or PNP open collector output, 3 V or less and 5 ma or less, voltage drop 2.4 V or less, PLC/relay compatible Error output signal NPN or PNP open collector output, 3 V or less and 5 ma or less, voltage drop 2.4 V or less, PLC/relay compatible Direct memory setting 1 to 1 kpa 5 to 5 kpa 9 to 9 kpa (Min. setting width 1 kpa/setting resolution 1 kpa) (Min. setting width 1 kpa/setting resolution 1 kpa) (Min. setting width 1 kpa/setting resolution 2 kpa) Display method 7-segment LED 3 digits, indicator accuracy: ±2% F.S. or less Pressure display Display range ( psi) to 1 kpa ( 15 psi) ( psi) to 5 kpa ( 73 psi) ( psi) to 9 kpa ( 13 psi) Display resolution 1 kpa (.1 psi,.1 bar) 1 kpa (.1 psi,.1 bar) 1 kpa (.1 psi,.1 bar) Hysteresis *3.5% F.S. or less Linearity *3 ±.3% F.S. or less Resolution *3.2% F.S. or less Repeatability *3.3% F.S. or less Temperature Zero point fluctuation.15% F.S./ C or less characteristics Span fluctuation.7% F.S./ C or less Max. flow rate (ANR) *4 6 l/min 4 l/min Step response *5 No load.2 sec. or less Vibration resistance 98 m/s 2 or less Ambient temperature 5 (41 F) to 5 (122 F) C Fluid temperature 5 (41 F) to 5 (122 F) C Port size Rc1/4 Mounting orientation Free Weight 25 g Protection circuit Power reverse connection protection, switch output reverse connection protection, switch output load short-circuit protection *1: There is 1% F.S. or less residual pressure when the input signal is %. (EVD-11: 1 kpa, EVD-15: 5 kpa, EVD-19: 9 kpa) *2: Select the analog output or switch output. *3: The condition of the values above is: 24 ±.1 VDC power supply voltage, 25 ± 3 C ambient temperature, no load, working pressure of +5 kpa max. control pressure (EVD-11)/+1 kpa (EVD-15, 19), and 1 to 9% control pressure. In addition, when the secondary side is a closed circuit, pressure fluctuations will occur if the product is used for blowing or for similar applications. *4: The characteristics where working pressure is maximum and control pressure is maximum are shown. *5: The value above is obtained at the max. working pressure and when the step amount changes from 5% F.S. 1% F.S. 5% F.S. 6% F.S. 5% F.S. 4% F.S. Specifications for components for rechargeable battery production EVD15/19 [Input specifications/port size/output specifications] [Option] EVD35/39 [Input specifications/port size/output specifications] [Option] Contact your nearest CKD sales office or dealer for details. 512 R P A 1 MPa 145. psi, 1 MPa = 1 bar (Catalog No. CC-1226A) 3 3 P4 P4

EVD-1 Series How to order/internal structure How to order EVD-1 5 8 AN C1B1 3 Code Content A Pressure control range A Pressure control range *1 1 to 1 kpa 5 to 5 kpa 9 to 9 kpa B Input signal B Input signal to 1 VDC 1 to 5 VDC 2 4 to 2 madc P Parallel 1 bit C Port size C Port size 8 Rc1/4 D Output signal D Output signal AN 1 to 5 V analog, error (NPN) AP 1 to 5 V analog, error (PNP) SN Switch (NPN), error (NPN) SP Switch (PNP), error (PNP) E Option E Option Cable option Blank None C1 Analog 9-conductor, 1 m cable C3 Analog 9-conductor, 3 m cable P1 Parallel 15-conductor, 1 m cable P3 Parallel 15-conductor, 3 m cable F Power supply voltage Bracket option attached Discrete option (cable, bracket) model No. Blank None B1 B type bracket, floor mounted EVD- C1 L1 L type bracket, wall mounted F Power supply voltage 3 24 VDC E Option *1: There is a 1% F.S. or less residual pressure when the input signal is %. Spd Internal structure and parts list 1 9 No. Part name Material 1 Lid PBT resin 2 3 1 11 2 D sub-connector - 3 Housing ABS resin 4 oller board - 5 3-way valve - 6 Valve base Polyphenylene sulfide resin 7 Pilot chamber Polyphenylene sulfide resin 4 5 12 13 8 Body Aluminum alloy die-casting 9 Pressure sensor - 1 Diaphragm Special nitrile rubber 11 Relief seat Aluminum alloy 6 14 12 Steel ball (exhaust valve) Stainless steel 13 Valve Special nitrile rubber, stainless steel 14 Bottom rubber Silicone rubber 7 15 15 Bottom plug Copper alloy, electroless nickeling 16 O-ring Fluoro rubber 8 16 Cannot be disassembled 513

EVD-1 Series Dimensions 48.6 Spd 514 36 IN 42 27 Optional dimensions OUT B type bracket (-B1): Floor mounted 36 27 8-φ3.5 φ5.3 EXH port φ22 4-M3 depth 6 * Refer to page 521 for details of cable option dimensions. 36 27 56 64 44 1 4-full R 4.4 4.4 1.6 D sub-connector 15-pin/plug (male) 3 7.2 44 21 Material : SPCC Weight : 32g 2-Rc1/4 Ni plated 18 (17) 2-#4-4OUNC L type bracket (-L1): Wall mounted 3.5 4-full R 1 36 4.4 27 3.5 3.5 42 22 32 42 1.6 5 8 51 17.5 φ4.2 R port (Pilot air exhaust port) 5 Material : SPCC Weight : 21g Ni plated

I/O characteristics EVD-11 EVD-15 1 5 9 45 ol pressure (kpa) Analog output (analog output only: model No. AN/AP) EVD-11 Analog output (VDC) 5 4 3 2 1 Flow characteristics EVD-11 ol pressure (kpa) Relief characteristics EVD-11 ol pressure (kpa) 8 4 7 35 6 3 5 25 4 2 3 15 2 4 6 8 ol pressure (kpa) EVD-1 Series I/O characteristics/monitor output/flow characteristics/relief characteristics 2 1 1 5 1 2 3 4 5 6 7 8 9 1 VDC 1 2 3 4 5 6 7 8 9 1 VDC.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. VDC.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. VDC 4 5.6 7.2 8.8 1.4 12. 13.6 15.2 16.8 18.4 2. madc 4 5.6 7.2 8.8 1.4 12. 13.6 15.2 16.8 18.4 2. madc Input signal Input signal 12 1 8 6 4 2 12 1 8 6 4 2 Working pressure 16 kpa 1 ol pressure (kpa) EVD-15 Analog output (VDC) 5 4 3 2 1 EVD-15 ol pressure (kpa) ol pressure (kpa) 6 5 4 3 2 1 1 2 3 4 ol pressure (kpa) Working pressure 7 kpa 5 EVD-19 ol pressure (kpa) 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 VDC.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. VDC 4 5.6 7.2 8.8 1.4 12. 13.6 15.2 16.8 18.4 2. madc Input signal EVD-19 Analog output (VDC) 5 4 3 2 1 EVD-19 ol pressure (kpa) ol pressure (kpa) 1 2 3 4 5 6 7 8 9 ol pressure (kpa) Working pressure 1 kpa 2 4 6 8 1 12 2 4 6 1 2 3 4 5 Flow rate [ /min (ANR)] Flow rate [ /min (ANR)] Flow rate [ /min (ANR)] EVD-15 EVD-19 Working pressure 16 kpa Working pressure 7 kpa 6 1 Working pressure 1 kpa 9 5 8 4 7 6 3 5 4 2 3 1 2 1 2 4 6 8 1 12 14 1 2 3 4 1 2 3 4 5 6 Flow rate [ /min (ANR)] Flow rate [ /min (ANR)] Flow rate [ /min (ANR)] 1 9 8 7 6 5 4 3 2 1 6 Spd 515

Spd 516 Specifications Descriptions Working fluid EVD-31-*8 EVD-31-*1 Analog (* /1/2) JIS symbol EVD-31-P8 EVD-31-P1 Parallel EVD-35-*8 EVD-35-*1 Analog (* /1/2) EVD-35-P8 EVD-35-P1 Parallel EVD-39-*8 EVD-39-*1 Analog (* /1/2) Clean compressed air (JIS B 8392-1: 212 (ISO 8573-1: 21) [1:3:2] or equivalent) EVD-39-P8 EVD-39-P1 Parallel Max. working pressure 16 kpa ( 23 psi, 1.6 bar) 7 kpa ( 1 psi, 7 bar) 1 kpa ( 15 psi, 1 bar) Min. working pressure Set pressure +5 kpa ( 7.3 psi) Set pressure +1 kpa ( 15 psi, 1 bar) Proof pressure Inlet 24 kpa ( 35 psi, 2.4 bar) 15 kpa ( 15 psi, 1.5 bar) 15 kpa ( 22 psi, 15 bar) Output side 15 kpa ( 22 psi, 1.5 bar) 75 kpa ( 11 psi, 7.5 bar) 135 kpa ( 2 psi, 13.5 bar) Pressure control range *1 ( psi) to 1 kpa ( 15 psi) ( psi) to 5 kpa ( 73 psi) ( psi) to 9 kpa ( 13 psi) Power supply voltage Digital electro pneumatic regulator EVD-3 Series R P 24 VDC ± 1% (stabilized power supply with ripple rate 1% or less) Current consumption.15 A or less (.6 A or less rush current when the power is turned ON) to 1 VDC(6.7 kω) to 1 VDC(6.7 kω) to 1 VDC(6.7 kω) Input signal to 5 VDC(1 kω) 1 bit to 5 VDC(1 kω) 1 bit to 5 VDC(1 kω) (input impedance) 4 to 2 madc(25 Ω) 4 to 2 madc(25 Ω) 4 to 2 madc(25 Ω) 1 bit Preset input 8 points None 8 points None 8 points None Output signal *2 Output accuracy: ±6% F.S. or less, analog output: 1 to 5 VDC (connecting load impedance 5 kω and over) Switch output: NPN or PNP open collector output, 3 V or less and 5 ma or less, voltage drop 2.4 V or less, PLC/relay compatible Error output signal NPN or PNP open collector output, 3 V or less and 5 ma or less, voltage drop 2.4 V or less, PLC/relay compatible Direct memory setting 1 to 1 kpa 5 to 5 kpa 9 to 9 kpa (Min. setting width 1 kpa/setting resolution 1 kpa) (Min. setting width 1 kpa/setting resolution 1 kpa) (Min. setting width 1 kpa/setting resolution 2 kpa) Display method 7-segment LED 3 digits, indicator accuracy: ±2% F.S. or less Pressure display Display range ( psi) to 1 kpa ( 15 psi) ( psi) to 5 kpa ( 73 psi) ( psi) to 9 kpa ( 13 psi) Display resolution 1 kpa (.1 psi,.1 bar) 1 kpa (.1 psi,.1 bar) 1 kpa (.1 psi,.1 bar) Hysteresis *3.5% F.S. or less Linearity *3 ±.3% F.S. or less Resolution *3.2% F.S. or less Repeatability *3.3% F.S. or less Temperature Zero point fluctuation.15% F.S./ C or less characteristics Span fluctuation.7% F.S./ C or less Max. flow rate (ANR) *4 7 l/min 15 l/min Step response *5 No load.2 sec. or less Vibration resistance 98 m/s 2 or less Ambient temperature 5 (41 F) to 5 (122 F) C Fluid temperature 5 (41 F) to 5 (122 F) C Port size IN, OUT port Port size option 8 Rc1/4, 1 Rc3/8 EXH port Rc3/8 Mounting orientation Free Weight 45 g Protection circuit Power reverse connection protection, switch output reverse connection protection, switch output load short-circuit protection *1: There is 1% F.S. or less residual pressure when the input signal is %. (EVD-31: 1 kpa, EVD-35: 5 kpa, EVD-39: 9 kpa) *2: Select the analog output or switch output. *3: The condition of the values above is: 24 ±.1 VDC power supply voltage, 25 ± 3 C ambient temperature, no load, working pressure of +5 kpa max. control pressure (EVD-31)/+1 kpa (EVD-35, 39), and 1 to 9% control pressure. In addition, when the secondary side is a closed circuit, pressure fluctuations will occur if the product is used for blowing or for similar applications. *4: The characteristics where working pressure is maximum and control pressure is maximum are shown. *5: The value above is obtained at the max. working pressure and when the step amount changes from 5% F.S. 1% F.S. 5% F.S. 6% F.S. 5% F.S. 4% F.S. A 1 MPa 145. psi, 1 MPa = 1 bar

EVD-3 Series How to order/internal structure How to order EVD-3 5 8 AN C1B3 3 E Option B Input signal C Port size (IN,OUT) D Output signal Internal structure and parts list Code A Pressure control range *1 1 to 1 kpa 5 to 5 kpa 9 to 9 kpa Input signal to 1 VDC 1 to 5 VDC 2 4 to 2 madc P Parallel 1 bit C Port size (IN, OUT) 8 Rc1/4 1 Rc3/8 D Output signal AN 1 to 5 V analog, error (NPN) AP 1 to 5 V analog, error (PNP) SN Switch (NPN), error (NPN) SP Switch (PNP), error (PNP) E Option E Option Cable option Blank None C1 Analog 9-conductor, 1 m cable C3 Analog 9-conductor, 3 m cable P1 Parallel 15-conductor, 1 m cable F Power supply voltage P3 Parallel 15-conductor, 3 m cable Discrete option (cable, bracket) model No. Bracket option attached Blank None EVD- C1 B3 B type bracket, floor mounted L3 L type bracket, wall mounted 1 2 3 A Pressure control range 1 11 B Power supply voltage 3 24 VDC F Content *1: There is 1% F.S. or less residual pressure when the input signal is %. No. Part name Material 1 Lid PBT resin 2 D sub-connector - 3 Housing ABS resin 4 oller board - 5 3-way valve - 6 Valve base Polyphenylene sulfide resin 7 Pilot chamber Polyphenylene sulfide resin Spd 4 5 12 13 8 Piston body assembly Aluminum alloy die-casting,. 9 Body Aluminum alloy die-casting 1 Pressure sensor - 6 14 11 Piston assembly Aluminum alloy, stainless steel,. 12 Spring Stainless steel 13 Top valve Copper alloy, special nitrile rubber 7 8 15 16 14 Bottom valve Copper alloy, special nitrile rubber 15 Bottom cap Copper alloy 16 O-ring Nitrile rubber 17 Base plate Steel plate 9 17 Cannot be disassembled 517

EVD-3 Series Dimensions Spd IN 24 Optional dimensions B type bracket (-B3): Floor mounted 38 24 5 38 8-φ4.5 OUT 38 24 71 87 53.2 4-full R * Refer to page 521 for details of cable option dimensions. 52.4 φ32 133 D sub-connector 15-pin/plug (male) 2-Rc1/4 2-Rc3/8 2-M4 depth 12 6 6 1.6 25 78 3 5 12 Material : SPCC Weight : 48g Ni plated Silencer (sold separately) (model No.: SLW-1A) L type bracket (-L3): Wall mounted 8-φ4.5 38 24 7 25.7 (14) 38 24 5 26 36 5 φ32 Rc3/8 EXH port 36.5 2.3 7 61.5 22 2-#4-4OUNC 8 φ4.2 R port (Pilot air exhaust port) Material : SPCC Weight : 51g Ni plated 518

I/O characteristics EVD-31 EVD-35 1 5 9 45 ol pressure (kpa) Analog output (analog output only: model No. AN/AP) EVD-31 Analog output (VDC) 8 4 7 35 6 3 5 25 4 2 3 15 2 1 1 5 1 2 3 4 5 6 7 8 9 1 VDC 1 2 3 4 5 6 7 8 9 1 VDC.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. VDC.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. VDC 4 5.6 7.2 8.8 1.4 12. 13.6 15.2 16.8 18.4 2. madc 4 5.6 7.2 8.8 1.4 12. 13.6 15.2 16.8 18.4 2. madc Input signal Input signal 5 4 3 2 1 2 4 6 ol pressure (kpa) 8 1 ol pressure (kpa) EVD-35 Analog output (VDC) 5 4 3 2 1 1 2 3 ol pressure (kpa) 4 5 EVD-3 Series I/O characteristics/analog output EVD-39 ol pressure (kpa) 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 1 VDC.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. VDC 4 5.6 7.2 8.8 1.4 12. 13.6 15.2 16.8 18.4 2. madc Input signal EVD-39 Analog output (VDC) 5 4 3 2 1 1 2 3 4 5 6 7 ol pressure (kpa) 8 9 Spd 519

EVD-3 Series Spd Flow characteristics EVD-31-8 ol pressure (kpa) 12 1 8 6 4 2 EVD-35-8 ol pressure (kpa) 6 5 4 3 2 1 2 4 6 8 Flow rate [ /min (ANR)] EVD-39-8 Working pressure 78 kpa 1 9 8 7 6 5 4 3 2 1 5 1 15 2 25 3 35 4 45 5 Flow rate [ /min (ANR)] ol pressure (kpa) Relief characteristics Working pressure 16 kpa 1 2 3 Flow rate [ /min (ANR)] 1 Working pressure 7 kpa 4 EVD-31-1 ol pressure (kpa) 12 1 8 6 4 2 EVD-35-1 ol pressure (kpa) 6 5 4 3 2 1 EVD-39-1 ol pressure (kpa) 1 9 8 7 6 5 4 3 2 1 Working pressure 16 kpa 2 4 6 8 1 12 Flow rate [ /min (ANR)] Working pressure 7 kpa 1 2 3 Flow rate [ /min (ANR)] 4 Working pressure 78 kpa 5 1 15 2 25 3 35 4 45 5 Flow rate [ /min (ANR)] EVD-31 ol pressure (kpa) 12 1 8 6 4 2 Working pressure 16 kpa 2 4 6 8 1 Flow rate [ /min (ANR)] EVD-35 ol pressure (kpa) 6 5 4 3 2 1 Working pressure 7 kpa 1 2 3 4 Flow rate [ /min (ANR)] EVD-39 Working pressure 1 kpa 1 9 8 7 6 5 4 3 2 1 5 1 15 2 25 3 35 4 45 5 Flow rate [ /min (ANR)] ol pressure (kpa) 52

Cable optional dimensions EVD-C1,EVD-C3 EVD Series Cable optional dimensions D subsocket pin No. 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 Insulator color Brown Orange Yellow - Red - - - - Gray White - Green Blue Black Name Preset input signal Input Bit 1 Bit 2 Bit 3 Vacant Power supply + +24 VDC Vacant Vacant Vacant Vacant Common Note: The No. 1 pin common is the common for the preset input (pin No. 1 to 3). EVD-P1,EVD-P3 28.5 D subsocket pin No. to 1 VDC Input signal to 5 VDC Wire material Tinned annealed copper wire Conductor O.D. Approx..48 Outer diameter of insulator.88 Vacant Analog Switch output output Output 4 to 2 madc Vacant 1 to 5 VDC NPN or PNP output Error output Power NPN or PNP output supply - (V) Weight g C1:67 C3:166 Wire material Tinned annealed copper wire Conductor O.D. Approx..48 Outer diameter of insulator.88 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 Insulator color Brown Orange Yellow Purple Name 11 18.9 11 18.9 28.5 33.4 33.4 Parallel input signal Input Bit 1 Bit 2 Bit 3 Bit 4 D sub-connector 15-pin/socket (male) (φ1) (φ6) 1 3 D sub-connector 15-pin/socket (male) (φ1) (φ6.5) 1 3 Red Power supply + +24 VDC Light blue Pink White Red (with (with black line) black line) Parallel input signal Gray White Green (with black line) Parallel input signal Common Bit 5 Bit 6 Bit 7 Bit 8 Bit 9 Bit 1 Note: The No. 1 pin common is the common for the parallel input signal (pin No. 1 to 4, 6 to 9, 11, 12). Analog output Output 1 to 5 VDC 1 1 9-AWG26 15-AWG26 Green Blue Black Switch output NPN or PNP output Shielded wire * Connect the shielded wire to the power supply (-) ( V). Shielded wire * Connect the shielded wire to the power supply (-) ( V). Error output NPN or PNP output Power supply - ( V) Weight g P1:82 P3:25 Spd 521

EVD Series Wiring method - - - EVD-1 - AN- -, EVD-1-1 AN-, EVD-1-2 AN- EVD-3 - AN- -, EVD-3-1 AN-, EVD-3-2 AN- (Analog input, analog output + error output NPN output) - Spd Main circuit Output short-circuit protection circuit Example of internal circuit and load connection Analog input 5-pin (power +) 11-pin (analog input) 1-pin (preset bit 1) 2-pin (preset bit 2) 3-pin (preset bit 3) 1-pin (common) 13-pin (analog output) 14-pin (error output) 15-pin (power -) EVD-1 - SN- -, EVD-1-1 SN-, EVD-1-2 SN- EVD-3 - SN- -, EVD-3-1 SN-, EVD-3-2 SN- (Analog input, switch output + error output NPN output) Main circuit Output short-circuit protection circuit 5-pin (power +) 11-pin (analog input) 1-pin (preset bit 1) 2-pin (preset bit 2) 3-pin (preset bit 3) 1-pin (common) 13-pin (switch output) 14-pin (error output) 15-pin (power -) Connector pin layout (product body side) [Analog input type] 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 Voltage generator Voltage generator Load max5 ma Load Load Load max5 ma max5 ma The analog input type 4 + + EVD-1 - AP- -,EVD-1-1 AP-,EVD-1-2 AP- EVD-3 - AP- -,EVD-3-1 AP-,EVD-3-2 AP- (Analog input, analog output + error output PNP output) Main circuit Output short-circuit protection circuit EVD-1 - SP- -, EVD-1-1 SP-, EVD-1-2 SP- EVD-3 - SP- -, EVD-3-1 SP-, EVD-3-2 SP- (Analog input, switch output + error output PNP output) Main circuit Output short-circuit protection circuit 6 7 8 9 12 does not have the,,,, or pins. 5-pin (power +) 13-pin (analog output) 14-pin (error output) 11-pin (analog input) 1-pin (preset bit 1) 2-pin (preset bit 2) 3-pin (preset bit 3) 1-pin (common) 15-pin (power -) 5-pin (power +) 13-pin (switch output) 14-pin (error output) 11-pin (analog input) 1-pin (preset bit 1) 2-pin (preset bit 2) 3-pin (preset bit 3) 1-pin (common) 15-pin (power -) max5 ma Voltage generator max5 ma max5 ma Voltage generator Load Load Load Load + + 522

- - EVD Series Technical data - Example of internal circuit and load connection Parallel input EVD-1 -P AN- - EVD-3 -P AN- - (Parallel input, analog output + error output NPN output) - Main circuit 5-pin (power +) 12-pin (MSB bit 1) 11-pin (bit 9) 9-pin (bit 8) 8-pin (bit 7) 7-pin (bit 6) 6-pin (bit 5) 4-pin (bit 4) 3-pin (bit 3) 2-pin (bit 2) 1-pin (LSB bit 1) 1-pin (common) 13-pin (analog output) 14-pin (error output) 15-pin (power -) EVD-1 -P SN- - EVD-3 -P SN- - (Parallel input, switch output + error output NPN output) Main circuit Output short-circuit protection circuit Output short-circuit protection circuit 5-pin (power +) 12-pin (MSB bit 1) 11-pin (bit 9) 9-pin (bit 8) 8-pin (bit 7) 7-pin (bit 6) 6-pin (bit 5) 4-pin (bit 4) 3-pin (bit 3) 2-pin (bit 2) 1-pin (LSB bit 1) 1-pin (common) 13-pin (switch output) 14-pin (error output) 15-pin (power -) Connector pin layout (product body side) [Parallel input type] 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 Load max5 ma Load Load max5 ma max5 ma Load + + EVD-1 -P AP- - EVD-3 -P AP- - (Parallel input, analog output + error output PNP output) Main circuit EVD-1 -P SP- - EVD-3 -P SP- - (Parallel input, switch output + error output PNP output) Main circuit Output short-circuit protection circuit Output short-circuit protection circuit 5-pin (power +) 13-pin (analog output) 14-pin (error output) 12-pin (MSB bit 1) 11-pin (bit 9) 9-pin (bit 8) 8-pin (bit 7) 7-pin (bit 6) 6-pin (bit 5) 4-pin (bit 4) 3-pin (bit 3) 2-pin (bit 2) 1-pin (LSB bit 1) 1-pin (common) 15-pin (power -) 5-pin (power +) 13-pin (switch output) 14-pin (error output) 12-pin (MSB bit 1) 11-pin (bit 9) 9-pin (bit 8) 8-pin (bit 7) 7-pin (bit 6) 6-pin (bit 5) 4-pin (bit 4) 3-pin (bit 3) 2-pin (bit 2) 1-pin (LSB bit 1) 1-pin (common) 15-pin (power -) max5 ma max5 ma max5 ma Load Load Load Load + + Spd 523

EVD Series Relation of parallel input signal and control pressure D sub-socket pin No. 12 11 9 8 7 6 4 3 2 1 Cable option insulator color Input type Green (with black line) Bit 1 MSB White Red (with black line) Input method The parallel input signal has 1 bits, and when converted into a decimal is -123. Input signal = EVD setting pressure (kpa)/maximum control pressure x 123 The maximum control pressure is 1 kpa for EVD-11 5 kpa for EVD-15 9 kpa for EVD-19. Example: When setting 3 kpa with EVD-15 3(kPa)/5(kPa) 123=613.8 614 When back calculating with a setting of 614, it will be 5(kPa) 614/123 3(kPa) When 614 (decimal) is converted into binary, the result is 11111. 1 sets the input signal to ON, and sets the input signal to OFF. (Refer to table below) White (with black line) Pink Light blue Purple Yellow Orange Brown Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 LSB Binary [for 614 (decimal)] 1 1 1 1 1 Spd Input signal ON OFF OFF ON ON OFF OFF ON ON OFF Relation of preset memory and input signal D sub-socket pin No. 3 2 1 Cable option insulator color Yellow Orange Brown Input type Bit 3 Bit 2 Bit 1 Input signal Preset memory OFF OFF OFF P1 OFF OFF ON P2 OFF ON OFF P3 OFF ON ON P4 ON OFF OFF P5 ON OFF ON P6 ON ON OFF P7 ON ON ON P8 524

MEMO Spd 525

EVD Series Spd Names and functions of display/operation section Output display (Red) Key Function list F is displayed when confirming the function setting. - lights up when switch output is ON. (Only when using switch output specifications) * Blinks when overcurrent is detected. E lights up when error output is ON. * Blinks when overcurrent is * If +/- should be specified or upper/lower limits have been set, or Use to enter each setting mode. When setting each data, this key is used to confirm the values,. Screen display Name Display content (RUN mode) Settings (Setting mode) Screen F1 Screen F2 is displayed. Pressure Display Input Signal Selection Zero /Span adjustment Secondary pressure is confirmed with the 3-digit numerical display LED. Unit: kpa The selected input signal and current target value (pressure conversion value) are confirmed. * When preset input (8-point) is selected, the currently selected preset No. and setting value are displayed. The validity of the zero/span adjustment and the setting value are confirmed. When valid, the F2.on - zero point adjustment value (L) and span point adjustment value (H) are alternately displayed. * The default setting is set with the full scale (--). 3-digit number LED display (green) Displays the pressure display and function setting details during RUN mode (pressure display). * The setting mode No. and setting details are displayed when displaying details of function settings. When setting each data, the values,., are displayed. Error code No. is displayed at error output. (Pressure display) Key (Setting details display) Setting mode No. Setting details (Error output) Setting details are sequentially displayed during RUN mode (pressure display). Use to select the setting when setting data. When setting each data, it is used to increase the values,. Key When setting each data, this key is used to select the numbers to each value,. For analog input: Analog input, preset memory input, or direct memory input is selected. For preset input/direct memory input, input the setting or this mode. For parallel input: Parallel input or direct memory input is selected. For direct memory input, input the setting for this mode. Code No. Select whether to use with full scale or zero/span adjustment. When zero/span adjustment is selected, the adjustment value for this mode can be set randomly. Setting Method P.529 P.53 Screen F3 Autopower OFF Auto-power OFF enabled/disabled can be confirmed. * The default setting is invalid (--). Auto-power OFF enabled/disabled can be selected. Note) The auto-power OFF time is set to approx. one minute. The time cannot be changed. P.53 Screen F4 Switch Output * Switch Output Specifications only The switch output enabled/disabled and setting value can be confirmed. When Mode 1 enabled is selected, the F4.-- tolerance range setting value (L) and - + tolerance range setting value (H) are alternately displayed. When Mode 2 enabled is selected, the F4.1 - min. setting value (L) and - max. setting value (H) are alternately displayed. * The default setting is invalid (--). Switch output enabled/disabled can be selected. When enabled, mode 1 or 2 can be selected. +/- tolerance values and max./min. values can be set as desired. Note) The hysteresis width cannot be set. P.53 Screen F5 * EVD- 1 only Proportional value Change Changes in the proportional value and its set level can be confirmed. When Proportional Value Up is selected, F5.H is displayed. When Proportional Value Down is selected, the F.5L - setting value is alternately displayed. * The default setting is standard (--). Select whether to use the standard value or whether to change the proportional value. The proportional value level is set in this mode only when Proportional Value Down is selected. (1 stages) P.531 526

Operating method RUN mode List of displayed contents F1 (input signal selection) screen F1 display descriptions The input signal and target value are alternately displayed. [Analog input] EVD- - - -, EVD- -1 - -, EVD- -2 - - Input signal code Content Analog to 1 VDC input * Analog to 5 VDC input * Analog 4 to 2 madc input * Preset memory input The selected preset No. is displayed. Direct memory input * One of [F1.A], [F1.A1] and [F1.A2] is displayed based on the model. F2 (zero/span adjustment) screen F2 display descriptions [Digital input] EVD- -P - - The validity of the zero/span adjustment and the setting value are confirmed. Note: This function is invalid if preset memory input or direct memory input is selected for F1 mode. When disabled When enabled 1% ol pressure % % Input signal code to (When disabled) Input signal 1% Target value (converted to pressure) Zero point Adjustment Set value (%) Span point Set value (%) Adjustment F3 (auto-power OFF) screen F3 display descriptions Auto-power OFF enabled/disabled can be confirmed. When disabled When enabled 1% Zero point (L) setting range to 5% % (When enabled) % Input signal 1% Span point (H) setting range 1 to 1% Input signal code EVD Series Operating method Content Parallel 1 bit input Direct memory input Spd 527

EVD Series RUN mode List of displayed contents F4 (switch output function) screen F4 display description (compatible model: EVD- - SN, EVD- - SP) The switch output enabled/disabled and setting value can be confirmed. Note) This is invalid with analog output specifications. (--) is displayed on the screen but cannot be used. When disabled When in Mode 1 - tolerance side Set value (%) + tolerance side Set value (%) When in Mode 2 H (+ tolerance side) Input signal set value L (- tolerance side) [Mode 1] Lower limit side Set value (%) Upper limit side Set value (%) H (upper limit side) L (lower limit side) [Mode 2] Output OFF ON ON OFF OFF ON Output ON OFF ON OFF ON OFF F5 (proportional value change) screen F5 display descriptions Compatible models: EVD-11- - -, EVD-31- - - Note) The screen is not displayed in EVD- 5/EVD- 9. The validity of the proportional value and the set level are confirmed. When disabled: ol is applied with standard values (default value). When enabled: Proportional value up or proportional value down is selected. The set level is selected from ten stages only when proportional value down is selected. Spd [Effect of increasing proportional value] ol pressure While the effect varies with piping and load capacity conditions, a higher accuracy in control is achieved. Hunting occurs easily, requiring care during use. Increased proportional value diagram standard setting Input signal ol pressure [Effect of decreasing proportional value] ol pressure Increased proportional value setting Input signal Pressure decrease Pressure increase If vibration occurs during blow applications or during a leakage test, stable control is ensured by decreasing the proportional value as shown below. Decreased proportional value diagram Before adjustment (standard setting) When disabled Time ol pressure After adjustment (decreased proportional value setting) Time When the proportional value is increased (H) When the proportional value is decreased (L) Setting level 528

EVD Series Operating method How to set setting mode CAUTION Release the key lock before changing setting details. (Refer to page 532) F1 (input signal selection function) Hold down the SET key for two seconds with the screen F1 displayed. F1 setting mode is entered. Changing the analog input signal selection Note: Analog input specifications cannot be changed. 2 seconds Changing parallel input signal selection When analog input is selected * Default setting Exits input signal selection setting mode, and returns to screen F1. After setting, exits setting mode and returns to screen F1. 2 seconds When preset memory input is selected Enters preset memory input setting mode (see below) 2 seconds When direct memory input is selected Enters direct memory input setting mode (see below) 2 seconds Exits input signal selection setting mode, and returns to screen F1. 2 seconds When parallel input is selected * Default setting After setting, exits setting mode and returns to screen F1. 2 seconds When direct memory input is selected Enters direct memory input setting mode (see below) 2 seconds Using preset memory input setting mode * Hold down the SET key for two seconds or longer with screen F1 preset memory input set. Spd 2 seconds Input the target value. Key: Moves digit 2 seconds Moves to the next No. after setting. Key: Counts up value Exits preset memory input setting mode and returns to screen F1. 2 seconds 2 seconds Input the target value. Key: Moves digit Key: Counts up value Using direct memory input setting mode * Hold down the SET key for two seconds or longer with screen F1 preset memory input set. 2 seconds Input the target value. Key: Moves digit Key: Counts up value After setting, exits setting mode and returns to screen F1. After setting, exits setting mode and returns to screen F1. 529

EVD Series How to set setting mode CAUTION Release the key lock before changing setting details. (Refer to page 532) F2 (zero/span adjustment function) Hold down the SET key for two seconds with the screen F2 displayed. F2 setting mode is entered. 2 seconds Exits zero/span adjustment setting mode and returns to screen F2. To use with full scale * Default setting After setting, exits setting mode and returns to screen F2. 2 seconds To use with zero/span adjustment 2 seconds 2 seconds 2 seconds Input the setting value. Input the setting value. Key: Moves digit Key: Moves digit Key: Counts up value Key: Counts up value After setting, exits setting mode and returns to screen F2. * This function cannot be used when preset memory input or direct memory input is selected with F1 (input signal selection function). Only full scale can be used. F3 (auto-power OFF function) Hold down the SET key for two seconds with the screen F3 displayed. F3 setting mode is entered. 2 seconds To disable auto-power OFF function * Default setting After setting, exits setting mode and returns to screen F3. 2 seconds To enable auto-power OFF function After setting, exits setting mode and returns to screen F3. Spd 2 seconds Exits auto-power OFF mode and returns to screen F3. * If any key is pressed during auto-power OFF, the display illuminates. * The auto-power OFF time is set to approx. one minute. The time cannot be changed. F4 (switch output function) Hold down the SET key for two seconds with the screen F4 displayed. F4 setting mode is entered. (Compatible models: EVD- - SN, EVD- - SP) Note: This is invalid with analog output. (--) is displayed on the screen but cannot be used. 2 seconds To disable switch output * Default setting After setting, exits setting mode and returns to screen F4. 2 seconds To enable switch output mode 1 After setting, exits setting mode and returns to screen F4. 2 seconds 2 seconds 2 seconds Input the setting value. Input the setting value. Key: Moves digit Key: Moves digit Key: Counts up value Key: Counts up value Exits switch output setting mode, and returns to screen F4. To enable switch output mode 2 2 seconds 2 seconds 2 seconds Input the setting value. Input the setting value. Key: Moves digit Key: Moves digit Key: Counts up value Key: Counts up value After setting, exits setting mode and returns to screen F4. 53

EVD Series Operating method How to set setting mode CAUTION Release the key lock before changing setting details. (Refer to page 532) F5 (Proportional value change function) Hold down the SET key for two seconds with the screen F5 displayed. F5 setting mode is entered. Compatible models: EVD-11- - -, EVD-31- - - Note) The screen is not displayed in EVD- 5/EVD- 9. 2 seconds After setting, exits setting mode and returns to screen F5. To disable the proportional value change function * Default setting After setting, exits setting mode and returns to screen F5. 2 seconds To use with increased proportional values After setting, exits setting mode and returns to screen F5. 2 seconds To use with decreased proportional values After setting, exits setting mode and returns to screen F5. 2 seconds Select the setting level. Key: Setting level up + Key: Setting level down After setting, exits setting mode and returns to screen F5. 2 seconds Select the setting level. Key: Setting level up + Key: Setting level down Spd 2 seconds After setting, exits setting mode and returns to screen F5. * When used with a decreased proportional value, operation takes place with the set level displayed on the screen when the set level is selected. When the set level is decided, press the SET key for two seconds or longer to enter the value. 531

EVD Series Key lock This function prevents incorrect operation. Release the key lock before changing settings. Operating the key lock Releasing the key lock Hold down simultaneously for 2 seconds * The key is locked every time the power is turned ON. Setting range of functions Hold down simultaneously for 2 seconds Function Settings display screen Setting details Setting specifications F1: Input signal selection function Preset memory input F1: Input signal selection function Direct memory input Set the target value (pressure). Set the target value (pressure). Range: *1 1 / to 1 5 / to 5 9 / to 9 Min. set unit: 1 kpa Range: *1 1 / to 1 5 / to 5 9 / to 9 Min. set unit: 1 kpa F2: Zero/span adjustment function Set the zero point adjustment value. Set the span point adjustment value. Range: to 5 *2 Min. set unit: 1% Range: 1 to 1 *2 Min. set unit: 1% Spd F4: Switch output function When in Mode 1 F4: Switch output function When in Mode 2 F5: Proportional value change function Increased proportional value F5: Proportional value change function Decreased proportional value Set the - tolerance value. Set the + tolerable value. Sets the min. value. Sets the max. value. The level cannot be set. Set the level. Range: - to -5 Min. set unit: -1% Range: to 5 Min. set unit: 1% Range: to 9 *2 Min. set unit: 1% Range: 1 to 1 *2 Min. set unit: 1% Range: 1 to 1 Min. set unit: 1 *1: If set to a pressure of 1% F.S. or less, it may not be possible to control pressure due to the effect of residual pressure. *2: The setting range may be limited depending on the setting value. F4: The switch output function is for the switch output only. Cannot be used with the analog output. Compatible models: EVD- - SN, EVD- - SP F5: The proportional value change function is limited to the pressure range 1 kpa. Compatible model: EVD-11-532

Default mode settings (Initialization) Screen display Name Settings display Setting details Screen F1 Screen F2 Screen F3 Screen F4 Screen F5 Error code Input signal selection Zero/span adjustment Auto-power OFF Switch output * Switch output specifications only Proportional value change * EVD- 1 only Analog A.A1.A2 Parallel When the above errors occur, the error displays and error output turns ON. Analog/ parallel input Full scale (zero/span adjustment disabled) Auto-power off disabled Switch output disabled Standard setting (Proportional value change disabled) Error display Cause Countermeasures The power voltage is not within the rating. Detected at 19.5 VDC or less detection accuracy ±1% The input signal exceeded the rating range. Detected at input 11% and over detection accuracy ±1% An error occurred during EEPROM reading or writing. An error occurred during memory reading or writing. Secondary pressure did not reach the set value for five seconds consecutively. 2% F.S. or less of the set value was not attained Detection accuracy ±6% F.S. ( ) The switch output s overcurrent protection circuit has operated. [Initializing] EVD Series Operating method Hold down simultaneously for 3 seconds Initializing Complete Check the product s specifications, set the power voltage within the rated range, then turn the power ON again. Check the product s input signal, set the input signal within the rated range, then turn the power ON again. Contact your nearest CKD branch or dealer. Contact your nearest CKD branch or dealer. Check primary pressure provide pressure within the rating range, then turn the power ON again. Check that there are no leaks from pipes, fitting, or devices. Correctly connect, then turn power ON again. If the error is not resolved, contact your nearest CKD branch or dealer. Check whether load current exceeds the rating. Correctly connect, then turn the power ON again. Spd 533

EVD Series Glossary Max. working pressure Maximum value of primary side pressure which can satisfy the specifications. Differs according to the pressure specifications. Min. working pressure The primary pressure value required to control up to the full scale pressure. Differs according to the pressure specifications. Proof pressure Pressure value under which the electro pneumatic regulator will not break even if momentarily applied. The supply side and output side guaranteed values are given separately to limit the withstand pressure of the pressure sensor mounted on the secondary side. Pressure control range Indicates the pressure which can be controlled. Depending on the product, residual pressure may be generated. With the EVD, 1% F.S. or less residual pressure is generated when the input signal is % F.S. Note: This is different from the guaranteed accuracy range. Refer to the hysteresis and linearity items below. Hysteresis (measurement circuit 1) The difference (D1) of the rise curve and lower curve when the input signal is reciprocated once between % and 1%, indicated as a percentage of the full scale (F.S.). (Hysteresis) = Maximum value of D1/FS control pressure x 1 [%] Note: The scope of warranty will differ according to the product. For EVD, 1% to 9% F.S. is the scope of warranty. (Straight line connecting center value at 1% F.S. and 9% F.S.) When characteristic curve is decreasing Hysteresis D1 D2 Linearity Linearity (measurement circuit 1) The input signal (X1)% F.S. and (X2)% F.S. when the input signal is reciprocated once between % F.S. and 1% F.S. The difference (D2) from the reference line connecting the % F.S. is indicated as a percentage of the full scale (F.S.). (Linearity) = Maximum When characteristic curve is increasing Characteristic curve center value Spd value of D2/FS control pressure x 1 [%] Note: The scope of warranty will differ according to the product. For EVD, it is X1=1% F.S., X2=9% F.S. % X1 X2 1% Resolution (measurement circuit 1) The min. value of the input signal generated when the control pressure changes, indicated as a percentage of the full scale (F.S.). The input signal is pressurized from % F.S. to 15% F.S. and held for 1 seconds or longer and the input signal is The value is indicated as the difference with the input signal obtained, then gradually increased until the control pressure starts to rise again. Conducted in the same way for input signal 5% F.S. and 85% F.S. Repeatability (measurement circuit 1) The maximum value of the control pressure variation when the same setting value is repeatedly applied is indicated as a percentage of the full scale (F.S.). The value is calculated with the variation of the control pressure (D3) when the input signals % F.S. and 5% F.S. are repeatedly applied. (Repeatability) = D3 / FS control pressure x 1 [%] Temperature characteristics Indicates the fluctuation of the control pressure according to changes in the ambient temperature (reference temperature 25 C) converted per 1 C. The characteristics are indicated for the zero point and span width. Maximum flow rate (measurement circuit 2) Indicates flow rate possible at control pressure 1% F.S. Relief characteristics (measurement circuit 3) Indicates the relation of the control pressure and exhaust flow rate when back pressure is applied on the secondary side from an external source in the pressure control state. The relief flow rate when the back pressure is gradually increased is measured. Step response (measurement circuit 1) Indicates the time for the control pressure to reach the set pressure in respect to a stepped input signal. Measures the time for the control pressure to reach the setting value ±5% F.S. range after the input signal is applied. 15% 95% % Input signal Set control pressure 1% Step response time (Response time) = Time to reach within ±5% of final value 534

CKD measurement circuit (Measurement circuit 1) (Measurement circuit 2) (Measurement circuit 3) P1 Outer diameter φ6 (inner diameter φ4) tube Outer diameter φ6 (inner diameter φ4) tube x 1 Inlet P1 Voltage generator P1 IN EXH Sample Sample Sample OUT Metering valve P2 Pressure detector P2 Metering valve Y Laminar flow Flow rate meter P2 Voltage generator X X-Y recorder Y Pressure detector X-Y recorder Back pressure side Differential pressure detector (flow rate) EVD Series Glossary Voltage generator Differential pressure detector (flow rate) X X-Y recorder Y Pressure detector (P2) X Spd 535

Spd 586 Product-specific cautions: Electro pneumatic regulator CAUTION CAUTION Do not use the product where the product is exposed to direct sunlight or may come in contact with water, oil,. Sufficiently flush the piping with air before connecting to proportional pressure controls. Prevent pipe from catching on parts of the sealing tape when piping. Mount the product as indicated in the productspecific cautions. When connecting pipes, wrap sealing tape in the opposite direction to the threading, from the inside position to within 2 mm from the pipe end. CAUTION Pneumatic components (Electro pneumatic regulator) Safety Precautions Be sure to read this section before use. Response is affected by working pressure and load volume. Also fluctuation of the working pressure affects the secondary side control pressure. If reproducibility with stable responsiveness is required, install a regulator in the preceding stage. Take the following countermeasures to prevent malfunction caused by noise. Install a line filter in the AC power supply line. Use a surge suppressor such as a CR or diode on the inductive load (solenoid valve, relay,.) and remove noise from the source. Keep wiring to devices separate from strong magnetic fields. Connect wiring to proportional pressure controls with a shield wire. Ground the shield wire on the power supply side. Note that the shielding wire for the serial transmission communication cable must be treated based on communication system specifications. When releasing the secondary control pressure, such as air blowing, into the atmosphere, the pressure could fluctuate depending on the piping and flow conditions. Test under actual working conditions, or contact CKD before using this method. Do not disassemble the product. Doing so may cause product failure. Operation after disassembly cannot be guaranteed. Design/selection Mounting, installation and adjustment Solid liquid sealant Solid liquid sealant Use/maintenance When selecting the dryer, air filter, oil mist filter or regulator, select a device with a flow rate higher than that used by proportional pressure controls. This product has moving parts due to its operation and structure, the accuracy,., of which can change over time. Before use, evaluate the part in the system. Depending on the operation frequency, use this product as a periodic maintenance part,. Working conditions for CE compliance CKD electro pneumatic regulators (EVD, EVR, EV, EVS2 and MEVT Series) conform to the EMC Directive and CE standard. The standard for the immunity for industrial environments applied to this product is EN61-6-2; the following requirements must be satisfied in order to conform to this standard: Conditions The evaluation of this product is performed by using a cable that has a power supply line and a signal line, paired to assess the product s performance. This product is not equipped with surge protection. Implement surge protection measures on the system side. If sealing tape protrudes from the pipe threads, it could be cut when screwing the bolts in. This could cause the tape to enter the pneumatic components, causing failures. Correct pressure control is not possible if the exhaust port is plugged. Release this port to the atmosphere. Use appropriate torque to tighten the pipes when connecting them. The purpose is to prevent air leakage and damage to bolts. First tighten the bolts by hand to ensure that the threads are not damaged, then use a tool. [Recommended tightening torque] Port thread Tightening torque N m M5 1 to 1.5 Rc1/4 6 to 8 Rc3/8 13 to 15 Tighten with an appropriate torque when using CKD cable option M12 connector. Recommended tightening torque:.4 to.49 N m Do not use with the cover and housing removed. An electronic circuit board is assembled inside. Using the product with the cover or housing removed could result in unexpected accidents or trouble.