F.R.L. Units Precautions 1 Be sure to read this before handling products.

Similar documents
F.R.L. Units Precautions 1 Be sure to read this before handling.

Filter-Regulator-Lubricator

Series AMJ. Drain Separator for Vacuum

Regulator. Accessory. Description. Symbol. Nil. With bracket. B With round. Port size. (Without limit indicator) With set nut (For panel mount)

Filter-Regulator-Lubricator

Related Products: Auto Drain Valve. Model/Specifications. Model

Pilot Check Valve: Metal Body Type

Filter regulator. Accessory. Description. Symbol. B With bracket With round. Port size. (Without limit indicator) Body size.

PVC Quick Drain Valve

Membrane Air Dryer. IDG1-C06 Series IDG1-C06-P Series

Series SFD. Clean Air Filter. Variations. Made to Order. Type. Cartridge (replaceable element) Disposable (non-replaceable element) Up to 100

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

Air operated valve. VGA342R Series

Regulator for 2 MPa ARX 20. How to Order. Bracket. Pressure gauge. Port size 1/8 1/4. Panel nut

Doc. No.SYJ300-OMO0002-A. Air Operated Valve PRODUCT NAME. SYJA300 / SYJ3000 Series MODEL/ Series

Maximum 0.85 MPa pressure setting Long-life, high flow perfect for balancer applications

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

Doc. No. AC -OMQ0008-B PRODUCT NAME AIR COMBINATION. MODEL/ Series AC10(A,B)- -A AC20(A,B,C,D)- -A AC25(B,C)- -A AC30(A,B,C,D)- -A AC40(A,B,C,D)- -A

Series IRV1000/2000/3000

5 Port Air Operated Valve

Clean Regulator/Fluororesin Type

SeriesTRBU. Flame Resistant (Equivalent to UL-94 Standard V-0) FR Double Layer Polyurethane Tubing

kpa or less 5.0. Compressed Air Preparation Filter. AFF/AM/AMD Series CAT.ES30-17B. 1 μm (Current model: 3 μm) 20% 60% 52% 160 mm.

/ Air Line Kit AL - M1202. / OPERATION MANUAL P1 - P9 / English P11 - P19 OM-K0651

PRODUCT NAME. Main Line Filter. MODEL / Series / Product Number

ALF400 to 900, ALT-5/-9

IR1000-A IR1010-A IR1020-A

PRODUCT NAME AIR FILTER. MODEL / Series / Product Number

Pressure Relief 3 Port Valve New. Sonic Conductance 45% With the indicator window Step1. With locking holes

Auto Feed Lube, Auto Feed Tank ALF400 to 900, ALT-5/-9

No.IL02-OM00011-A PRODUCT NAME LOCK UP VALVE. MODEL/ Series IL201 IL211

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Direct Operated Precision Regulator Modular Style. Standard Specifications

How to Order. Body size. Pressure: 2 MPa. Pressure increase ratio 0 Twice. Symbol. Thread type. Body size

Series AS-FPQ/AS-FPG. Speed Controller with One-touch Fitting for Clean Room. Speed controllers for clean room use

Power Valve: Precision Regulator. High precision, large capacity relief regulator

Low torque Metal seal type Rotary joint

Low Friction Cylinders

Operation Manual Air Saver Unit ASV5000 Series

Precision Regulator. Series Model Regulating pressure range Port size Page

AMG. Model Note) Rated flow (l/min (ANR)) Port size Mass (kg) 1 8, , 3 8. Specifications Fluid. Element life

Compressed Air Cleaning Filter Series

Doc. No.VFR3000-OMH0005-B. 5 Port Air Operated Valve PRODUCT NAME. VFRA3000, 4000 Series MODEL/ Series

LUBRICATOR ASSEMBLY AND OPERATING INSTRUCTIONS

Air preparation filter

Process Pump. Series PAF3000/Series PAF5000

Port size. Model Screw-in ZFA10 1/8 ZFA20 1/4 ZFB10 ZFB20 ZFB30 ZFB40 ZFC5 ZFC7

Hand Valve Series. Push-In Fitting Type Shut-off Valve (Residual Pressure Release Valve) Control Open/Close for Air Supply.

Coiling Tube with Twist-Proof Fitting

Process Pump. PAF3000 Series/PAF5000 Series

IX1 Spirax-Monnier International Compressed Air Filter Installation and Maintenance Instructions

Precision Regulator IR3120

Booster Regulator/Air Tank

VACUUM REGULATORS CONTENTS

Modular Type Regulators

Modular F.R.L. Units. New. New. Series AC 46% Better visibility and environmental resistance. Energy saving regulator

ALF400 to 900, ALT-5/-9

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

435 psi (3.0 MPa) Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. Maximum supply pressure. Set pressure range.

DC5A. Cyclone Separator Trap for Air. Copyright 2015 by TLV Co., Ltd. All rights reserved ISO 9001/ ISO MA-03 (DC5A) 19 June 2015

How to Order. Rc NPT 1/8 1/4 3/8 1/2

Model GP PRESSURE REDUCING VALVE Installation & Operation Manual

Compact Regulator. ARX20 Series. 2.0 MPa compatible, piston type compact regulator ARJ

5 Port Solenoid Valve

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

Model GPR Primary Pressure Regulating Valve. Instruction Manual

Push-In Fitting Type Silencer

30% (SMC comparison) Silencer. New. New. The M5 silencer is now added! The resin silencer is now a more compact size! Series AN.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

Industrial Filter. FGD series

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

Automatic Non-freeze Valve NF6

Cautions : 1. Be careful when you release the Stop Fitting with some internal pressure

Cautions : 1. Clogging of the element raises resistance to exhaust, thus lowering the

Vacuum Regulator. IRV10/20 Series. Weight reduced by. RoHS ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV

3-PIECE BALL VALVE, 3600 PSI/ PN 248, WITH ISO DIRECT MOUNTING PAD 306M SERIES/ PED Category II

PRESSURISED PAINT CONTAINER

Change Valve. Push-In Fitting Type Three-way Changeover Valve. Changeover Air Direction by 90. Lightweight and Compact Design.

Push-In Fitting Type Pressure Gauge

Process Pump. Self-priming makes priming unnecessary. Air operated type. Air supply port. 5 port solenoid valves. Application Example

3/8" Dr. Air Butterfly Impact Wrench

OPERATION MANUAL NTF-15

MF2M Monnier Miniature Compressed Air Filter

(1) Type (2) Cylinder dia. (3) Gripper action : Single-acting closing gripper (normally open) (4) Holder type

ML3M Monnier Miniature Compressed Air Lubricator

INSTALLATION & MAINTENANCE INSTRUCTION

(1) Type (2) Thread size (T) (3) Wrench size specification : inch spec. (NPT, UNF) : mm spec. (M, R)

Precision Regulator. IR1000/2000/3000 Series ARJ ARX AMR ARM ARP IR -A IR IRV VEX SRH SRP SRF ITV IC ITVH ITVX PVQ VY1 AP100.

1 DRIVE INDUSTRIAL IMPACT WRENCH

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

Series VBA1110 to 4200

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Process Pump PB1000A

Process Pump Automatically Operated Type (Internal Switching Type) Air Operated Type (External Switching Type) How to Order. Option. Symbol.

Atmospheric relief valve type 1100 Installation and maintenance instructions

System Pressure Manager Standard & System Pressure Manager Plus

Transcription:

Precautions 1 1. Confirm the specifications. Products represented in this catalog are designed only for use in compressed air systems (including vacuum). Do not operate at pressures, temperatures, etc., beyond the range of specifications, as this can cause damage or malfunction. (Refer to the specifications.) Please contact SMC when using a fluid other than compressed air. We do not guarantee against any damage if the product is used outside of the specification range. 2. The standard bowl for the air filter, filter regulator, and lubricator, as well as the sight dome for the lubricator are made of polycarbonate. Do not use in an environment where they are exposed to or come in contact with organic solvents, chemicals, cutting oil, synthetic oil, alkali, or thread lock solutions. Effects of atmosphere of organic solvents and chemicals, and where these elements are likely to adhere to the equipment Chemical data for substances causing degradation (Reference) Type Acid Alkaline Inorganic salts Chlorine solvents Aromatic series Ketone Alcohol Oil Ester Ether Cutting oil Methyl amino Brake oil additives Rubber accelerator Thread-lock fluid Seawater Leak tester : Essentially safe : Some effects may occur : Effects will occur When the above factors are present, or there is some doubt, use a metal bowl for safety. Amino Other Chemical name Hydrochloric acid Sulfuric acid, Phosphoric acid Chromic acid Sodium hydroxide (Caustic soda) Potash Calcium hydroxide (Slack lime) Ammonia water Carbonate of soda Sodium sulfide Potassium nitrate Sulfate of soda Carbon tetrachloride Chloroform Ethylene chloride Methylene chloride Benzene Toluene Paint thinner Acetone Methyl ethyl ketone Cyclohexane Ethyl alcohol IPA Methyl alcohol Gasoline Kerosene Phthalic acid dimethyl Phthalic acid diethyl Acetic acid Methyl ether Ethyl ether Application examples Acid washing liquid for metals Degreasing of metals Industrial salts Water-soluble cutting oil Cleansing liquid for metals Printing ink Dilution Coatings Dry cleaning Photographic film Dry cleaning Textile industries Antifreeze Adhesives Synthetic oil Anti-rust additives Brake oil additives Material Polycarbonate Nylon 3. Do not use in such a way as to frequently fill or release the pressure from the standard bowls, such as the air filter, filter regulator, lubricator, etc. Damage to the bowl may occur. A metal bowl is recommended in these cases. 4. Please consult with SMC if the intended application calls for absolutely zero leakage, due to special atmospheric requirements, or if the use of a fluid other than air is required. 5. The mineral grease used on internal sliding parts and seals may come in contact with outlet side components. Please consult with SMC if this is not desirable. Please contact SMC if the Safety Data Sheet (SDS) of the grease is required. 6. Do not disassemble the product or make any modifications, including additional machining. Doing so may cause human injury and/or an accident. 1. Select a model that is suitable for the desired air cleanliness by referring to the SMC Best Pneumatics No. 6 catalog. 1. Operation manual Install the products and operate them only after reading the operation manual carefully and understanding its contents. Also, keep the manual where it can be referred to as necessary. 2. Ensure sufficient space for maintenance activities. When installing the products, allow access for maintenance and inspection. 3. Tighten threads with the proper tightening torque. When installing the products, follow the listed torque specifications. 1. To avoid reversed connections of the air inlet/outlet, make connections after confirming the IN/OUT marks or arrows that indicate the direction of air flow. Reversed connections 2. Components with a bowl, e.g., an air filter, filter regulator, or lubricator, must be installed vertically with the bowl facing downward so that faulty drain discharge and dripping can be checked. 3. Ensure sufficient top, bottom, and front clearance for maintenance and operation of each component. Refer to the dimensions section for the minimum clearance of each component. 46

Precautions 2 1. To screw piping material into a component, tighten with the recommended tightening torque while holding the female thread side. If the tightening torque is insufficient, looseness or seal failure may occur. On the other hand, excess tightening torque can cause damage to the threads. Furthermore, tightening without holding the female thread side can cause damage due to the excess force that is applied directly to the piping bracket. Recommended Tightening Torque Unit: N m Connection thread M5 1 8 1 4 3 8 1 2 3 4 1 1 1 4 1 1 2 2 Torque 1 to 1.5 1 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 40 to 42 48 to 50 48 to 50 1 After tightening by hand, use a tightening tool to tighten an additional 1/6 to 1/4 turn. 2. Winding of sealant tape When screwing piping or fittings into ports, ensure that chips from the pipe threads or sealing material do not enter the piping. Also, if sealant tape is used, leave 1.5 to 2 thread ridges exposed at the end of the threads. Winding direction Expose approx. 2 threads Sealant tape 3. Refer to the Fittings and Tubing Precautions (pages 52 to 56) for handling One-touch fittings. 2. Avoid excessive torsional moment or bending moment other than those caused by the equipment s own weight, as this can cause damage. Support external piping separately. 3. materials without flexibility, such as steel tube piping, are prone to be affected by excess moment loads and vibrations from the piping side. Use flexible tubing in between to avoid such effects. 1. Preparation before piping Before piping is connected, it should be thoroughly blown out with air (flushing) or washed to remove chips, cutting oil, and other debris from inside the pipe. Air Supply 1. Type of fluids Please consult with SMC when using the product in applications other than compressed air. 2. Take measures to ensure air quality, such as by installing an aftercooler, air dryer, or water separator. Compressed air that contains a large amount of drainage can cause the malfunction of pneumatic equipment, such as filters, regulators, and lubricators. Therefore, take appropriate measures to ensure air quality, such as by providing an aftercooler, air dryer, or water separator. 3. Drain flushing If condensation in the drain bowl is not emptied on a regular basis, the bowl will overflow and allow the condensation to enter the compressed air lines. This causes the malfunction of pneumatic equipment. If the drain bowl is difficult to check and remove, the installation of a drain bowl with an auto drain option is recommended. For compressed air quality, refer to the Air Preparation Equipment Selection Guide (Best Pneumatics No. 6). 4. Use clean air. Do not use compressed air that contains chemicals, synthetic oils that include organic solvents, salt, corrosive gases, etc., as it can cause damage or malfunction. When synthetic oil is used for the compressor oil, depending on the type of synthetic oil used or on the conditions of use, there may be adverse effects on the resin of the pneumatic equipment or on the seals if the oil is flowed out to the outlet side. The mounting of a main line filter is recommended in such cases. 47

Precautions 3 Air Supply 1. Ensure that the fluid and ambient temperatures are within the specified range. When using at low temperatures, drain or moisture could solidify or freeze, causing damage to the seals or equipment malfunction. If the fluid temperature is less than 5 C, the moisture in the circuit could freeze, causing damage to the seals or equipment malfunction. Therefore, take appropriate measures to prevent freezing. For compressed air quality, refer to the Air Preparation Equipment Selection Guide (Best Pneumatics No. 6). Operating Environment 1. Do not use in an atmosphere containing corrosive gases, chemicals, sea water, water, water steam, or where there is direct contact with any of these. Refer to each construction drawing for information on the materials of F.R.L. units. 2. Do not expose the product to direct sunlight for an extended period of time. 3. Do not use in a place subject to heavy vibration and/or shock. 4. Do not mount the product in locations where it is exposed to radiant heat. 1. Perform maintenance and inspection according to the procedures indicated in the operation manual. If handled improperly, malfunction or damage of machinery and equipment may occur. 2. work If handled improperly, compressed air can be dangerous. Assembly, handling, repair, and element replacement of pneumatic systems should be performed by a knowledgeable and experienced person. 3. Drain flushing Remove drainage from air filters regularly. 4. Removal of equipment, and supply/exhaust of compressed air Before components are removed, first confirm that measures are in place to prevent workpieces from dropping, run-away equipment, etc. Then, cut off the supply pressure and electric power, and exhaust all compressed air from the system using the residual pressure release function. When machinery is restarted, proceed with caution after confirming that appropriate measures are in place to prevent sudden movement. 5. Perform periodical inspections to detect any cracks, scratches, or other deterioration of the transparent resin bowl of the air filter, filter regulator, and lubricator or the sight dome of the lubricator. Replace with a new bowl, sight dome, or metal bowl when any kind of deterioration is found. Otherwise, damage may occur. 6. Perform periodical inspections to detect dirt on the transparent resin bowl of the air filter, filter regulator, and lubricator or the sight dome of the lubricator. When you find dirt on any of the above devices, clean with a mild household cleanser. Do not use other cleaning agents, as damage may occur. 1. Perform periodical inspections of the filter element and replace it as necessary. Check the element whenever the outlet pressure drops below normal or air does not flow smoothly during operation. 48

Precautions 4 A Regulator/Filter Regulator 1. Attach a safety device if damage or malfunction of equipment and devices on the outlet side may result from the output pressure exceeding the set pressure. 2. Residual pressure release (outlet pressure release) is not complete by releasing the inlet pressure. To release residual pressure, select a model with a back-flow mechanism. Using a model without a back-flow mechanism may cause unstable residual pressure release (i.e., residual pressure may or may not be released) depending on the operating conditions. 3. Please contact SMC if air will not be consumed in the system for long periods of time or if the outlet side will be used with a sealed circuit and a balanced circuit, since this may cause the set pressure of the outlet side to fluctuate. 4. Set the outlet pressure range for the regulator at 85% or less of the inlet pressure. If set above 85%, the inlet pressure will be easily affected by fluctuations in the flow rate and inlet pressure, and will become unstable. 5. Since a safety margin is calculated into the maximum regulating pressure value of the set pressure range appearing in the catalog s specification table, the set pressure may exceed the range. 6. Please contact SMC when a circuit requires the use of a regulator having relief sensitivity with high precision and setting accuracy. 1. Air consumption is 0.1 L/min. (ANR) or less under standard operation specifications. Please consult with SMC if this value is not allowable. 1. When adjusting the pressure, unlock the knob first, and relock it after the pressure is set. Adjustment 1. Set the regulator while confirming the displayed values of the inlet and outlet pressure gauges. Turning the knob excessively can cause damage to the internal parts. 2. Do not use a tool on the pressure regulator knob, as this can cause damage. It must be operated by hand. 49 Regulator/Filter Regulator Adjustment 1. Check the inlet pressure before setting. 2. The pressure gauge included with products for 0.02 to 0.2 MPa setting is for up to 0.4 MPa only. Do not apply pressure exceeding 0.4 MPa. It can damage the pressure gauge. 3. To set the pressure using the knob, turn the knob in the direction that increases pressure and lock the knob after the pressure is set. If this is done in the direction that decreases pressure, the pressure may drop from the original set pressure. Turning the knob clockwise increases the outlet pressure, and turning it counterclockwise reduces the pressure. Lubricator 1. Select a lubricator with a fixed throttle when the lubricator is used in high-frequency operations, such as in a press machine. When selecting a model, it is necessary to select the passage area of the fixed throttle, so please consult with SMC. 2. Lubrication cannot be properly performed if the operating flow rate is too low. Select an appropriately sized lubricator by referring to the minimum dripping flow rate provided in the catalog. 3. Mount a pressure relief 3-port valve on the inlet side, and avoid the use of a lubricator that causes backflow, as this may cause damage to the internal parts. 4. Use a check valve (AKM series) to prevent the backflow of lubricant when the piping is branched at the inlet side. 1. Avoid riser piping and branch lines on the outlet side to prevent inferior lubrication. 1. Use class 1 turbine oil (without additives) ISO VG32. Using other lubricant can cause damage to devices or result in malfunction. 2. For the AL10, 20 type, supply the lubricant after releasing the inlet pressure, since the lubricant cannot be applied under pressurized conditions. 1. Check the usage rate once a day. If the lubricant is not normally consumed, problems may occur to the lubricated objects.

Precautions 5 Mist Separator/Micro Mist Separator 1. Design the system so that a mist separator and a micro mist separator are installed where a pulsation is not likely to be generated. The pressure difference between the internal and external pressure inside the element should be kept within 0.1 MPa, since exceeding this value can cause damage. 1. To prevent damage to the filter element, replace it every 2 years or when the pressure drop becomes 0.1 MPa, whichever comes first. 2. Release the accumulated condensation inside air filter bowls periodically and before the accumulation reaches the maximum capacity. If accumulated condensation flows out to the outlet side, it Air Filter 1. To prevent damage to the element, replace the element every 2 years or when the pressure drop becomes 0.1 MPa, whichever comes first. 2. Release the accumulated condensation inside air filter bowls periodically and before the accumulation reaches the maximum capacity. If accumulated condensation flows out to the outlet side, it Air Combination 1. When using a 2-unit combination, such as the AC 0A, AC 0B, or AC 0D, secure the top and bottom of the bracket. For a 3-unit, securing the bottom side of the bracket is recommended. 2. The bracket position varies depending on the attachment (T-spacer or pressure switch) mounting. 3. The standard mounting position for a bracket is on the OUT side of each component (the AF, AR, AL, AW, and AFM). For the standard mounting position dimensions for brackets for mounting attachments, refer to Best Pneumatics No. 6. 4. A bracket cannot be mounted on both sides of a T-spacer or a pressure switch. 5. Please contact SMC if you wish to change the bracket mounting position. Float Type Auto Drain 1. Use an auto drain under the following conditions to avoid malfunction. <N.O. type> Operating compressor: 0.75 kw (100 L/min. (ANR)) or more When using 2 or more auto drains, multiply the above value by the number of auto drains to find the minimum capacity of the required compressors. Selecting a model with a minimum or larger required capacity is recommended. For example, when using 2 auto drains, a compressor capacity of at least 1.5 kw (200 L/min. (ANR)) is required. Operating pressure: 0.1 MPa or more <N.C. type> Operating pressure for AD17/27: 0.1 MPa or more Operating pressure for AD37/47: 0.15 MPa or more 1. Float type auto drain Drain piping should be performed under the following conditions to avoid malfunction. <N.O. type> Use piping whose I.D. is ø6.5 or larger, and whose length is 5 m or less. Avoid riser piping. <N.C. type> AD17/27: Use piping with an I.D. of ø2.5 or larger. AD37/47: Use piping with an I.D. of ø4 or larger. Length is 5 m or less. Avoid riser piping. 1. Turn the knob counterclockwise to release the drainage manually. Avoid applying excessive torque to the knob, such as by using a tool, as this can damage the auto drain. After releasing the condensation, turn the knob clockwise until it stops. 2. Air leakage or other performance malfunctions can occur if premature clogging of the element or pressure drop causes the pressure inside the bowl to deviate from the specified pressure range parameters. Check the pressure whenever such an irregularity occurs. When using a hexagon socket head cap screw to wall mount an air combination, we recommend using a ballpoint screwdriver. 50 A