OptiAir CA09 Pneumaticfluidizing

Similar documents
Pneumatic-fluidizing unit OptiAir CA12

PH300 Fresh powder hopper

OptiSpray AP01.1 Application Pump

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

MoveRoll Conveyor Operating and Maintenance Manual

Pressure maintenance valve SDV-P / SDV-P-E

Type 0404 / /2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation

Squeegee Unit for MRS Multi-Recovery System

Type Operating Instructions. 2/2-way solenoid valve 2/2-Wege Magnetventil Electrovanne 2/2 voies.

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 09.14

Waste Oil Extraction Unit

Installation & Maintenance Instructions TEC-11N TIMER. Analogue electronic timer 02/09

DIRECTIONS FOR USE / ASSEMBLING

TECHNICAL MANUAL HEAVY DUTY HORIZONTAL MICRO-COMPRESSOR Reference: RCMPH

Safety instructions and operating manual

Operating and maintenance manual Filter and reducing station Series / 1.0

Model 130M Pneumatic Controller

STAGE, STADIUM & X-TREME SHOT.

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

TEST BENCH SAFETY VALVES ¼ - 5 DN10 DN125

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

neska High-Speed Handpiece P320

Instruction Manual BA90 Precision Barometer

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

Safety Powder Spray Systems

Type 3709 Pneumatic Lock-up Valve. Translation of original instructions. Mounting and Operating Instructions EB 8391 EN

DIRECTIONS FOR USE / ASSEMBLING

Product Manual (Revision C) Original Instructions. Overspeed Dump Valve. Operation Manual

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

NHR Powder Feed Hopper

Pneumatic proportional controller Types M Types FM Function tested for use of the float in Ex-zone 0

Pneumatic spool valve islands

Instruction manual. for. high purity gas pigtails 200 bar / 300 bar

Pneumatic switch module 3/2-way valve (On/Off) Types P Types FP Function tested for use of the float in Ex-zone 0

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Encore PE 50-lb Feed Hopper

Table of Contents Documentation for PIT TROLLEY A4

Standard and Low-Flow Metric Powder Feed Pumps

Air Purge Unit. Series: LSP-compact Type: EJG 2-2. (Controlled with DigiFlow 515) Installation & Operation Manual 11/2014

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

INSTALLATION & MAINTENANCE INSTRUCTIONS

MECAIR CSN RAINTIGHT ENCLOSURE CLEAN AIR SOLUTIONS PRODUCT LEAFLET

For parts and technical support, call your nearest Finishing Customer Support Centre. Find your nearest centre at

DP Spare parts list. Demolition pulverizer. DP 2800 s/n DEQ Construction Tools GmbH No

Contents. Operating instructions. Pressure switch, heavy-duty version Model PSM-520

Pneumatic Target Transfer System Model PT01

Norrsken Family Booklet

NHR-X-X Encore Feed Hoppers

RTD Temperature sensor TH11

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Siphon vessel / Priming aid

Operation Manual. Hand tool for AMP DUOPLUG Customer Manual PN: en (Translation of the original German version)

CONDITIONS OF SALE AND WARRANTY

Metric Porcelain Enamel Powder Pump

MAGICFX CONFETTIPISTOL USER AND INSTALLATION MANUAL

Operation Manual Air Saver Unit ASV5000 Series

Installation and commissioning instructions 255 series and 256 series

HAMA H V compressor

PRAHER PLC-MP AQUASTAR MANAUL 2009

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Flow controller Type ED/CCB311 Instruction manual

3G Operating instructions. Digital Purge Gas Valve 3G Type: Document no.: D0001 Version: 01. July 2011/Rev.

USER S MANUAL BASIC HORIZONTAL OIL-LUBRICATED MICROCOMPRESSOR Reference: RCMPBH

Type 2000 INOX. Quickstart. English Deutsch Français. 2/2-way angle seat valve 2/2-Wege Schrägsitzventil Vanne à siège incliné 2/2 voies

INSTALLATION & MAINTENANCE INSTRUCTIONS DESCRIPTION SPECIFICATIONS. CE (EMC) Compliant

* * Data Sheet and Operating Manual. Digital manometer ME01 ## # 87 # HL S#### Dust explosion protection Zone 22.

Operating instructions and Assembly instructions (according to directive 2006/42/EC Annex VI) (ID-No ) Stud feeder HFN-6,5, FN-6,5

GAS FUEL VALVE FORM AGV5 OM 8-03

WIKA INSTRUMENT CORPORATION

Version-E E100930

Constant Pressure Inlet (CCN) Operator Manual

Operating Instructions in accordance with the Machines Directive 2006/42/EC

A17W49_MASEM_F_EN MANUAL

User Manual. Quantos Automated Dosing Liquid Module

Safety. Operating instructions Solenoid valve for gas VG 10/15 VG 65 DANGER. Contents WARNING CAUTION. Changes to edition 11.14

GRUNDFOS alldos product information. Vaccuperm 111 / 113. Vacuum gas dosing systems for chlorine gas, ammonia, sulphur dioxide and carbon dioxide

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Vibration isolation system 1VIS10W. User manual

Test and Adjustment Instructions Compressed Air Processing System Air Processing Unit (APU)

Instruction Manual Contact Pressure Vacuum Gauge

Instruction Manual Differential Pressure Transmitter

Model 6812C Dual Lane Scoreboard Owner s Manual

KEG PUMP. Range of Electric Keg Pumps

Instruction Manual EMA 84 Digital Pressure Gauge

original operating manual Operating manual TankQuick 100 F2 Translation of the Item-No.:

EVO Solid Downtube. Operators Manual for Downtubes fitted with zinc plated springs June 2004

INSTRUCTION MANUAL FOR MODEL 7360V VERTICAL CURING CHAMBER Revision E May

Type BBS-03, BBS-05, BBS-06, BBS-25

Semi-bulk packaging for fine-particle SIPERNAT products. Technical Information 1321

Animal Bed Rat Cryo. User Manual. Innovation with Integrity. Version MRI

LMU100/200 Series. Standard Specifications

[Instruments for vacuum measurement, checking and adjustment] 3

Composite Pistol-Type Air Needle Scaler OWNER S MANUAL

LC-SPE. Organizer 3.0 User Manual. Innovation with Integrity. Version 001 NMR

AUTOMATIC FILM APPLICATOR MICROPROCESSOR CONTROLLED. Operating Instructions for the

PNEUMATIC STOPPERS OPERATING MANUAL. Type F G H - FOG

OPERATION MANUAL NTF-15

Operating Instructions Temperature Measuring System MF420-5T-100

Transcription:

En Operating instructions and spare parts list OptiAir CA09 Pneumaticfluidizing unit Translation of the original operating instructions

Documentation OptiAir CA09 Pneumatic-fluidizing unit Copyright 2006 Gema Switzerland GmbH All rights reserved. This publication is protected by copyright. Unauthorized copying is prohibited by law. No part of this publication may be reproduced, photocopied, translated, stored on a retrieval system or transmitted in any form or by any means for any purpose, neither as a whole nor partially, without the express written consent of Gema Switzerland GmbH. MagicCompact, MagicCylinder, MagicPlus, MagicControl, OptiFlex, OptiControl, OptiGun, OptiSelect, OptiStar and SuperCorona are registered trademarks of Gema Switzerland GmbH. OptiFlow, OptiCenter, OptiMove, OptiSpeeder, OptiFeed, OptiSpray, OptiSieve, OptiAir, OptiPlus, OptiMaster, MultiTronic, EquiFlow, Precise Charge Control (PCC), Smart Inline Technology (SIT) and Digital Valve Control (DVC) are trademarks of Gema Switzerland GmbH. All other product names are trademarks or registered trademarks of their respective holders. Reference is made in this manual to different trademarks or registered trademarks. Such references do not mean that the manufacturers concerned approve of or are bound in any form by this manual. We have endeavored to retain the preferred spelling of the trademarks, and registered trademarks of the copyright holders. To the best of our knowledge and belief, the information contained in this publication was correct and valid on the date of publication. Gema Switzerland GmbH makes no representations or warranties with respect to the contents or use of this publication, and reserves the right to revise this publication and make changes to its content without prior notice. For the latest information about Gema products, visit www.gemapowdercoating.com. For patent information, see www.gemapowdercoating.com/patents or www.gemapowdercoating.us/patents. Printed in Switzerland Gema Switzerland GmbH Mövenstrasse 17 9015 St.Gallen Switzerland Phone: +41-71-313 83 00 Fax.: +41-71-313 83 83 E-Mail: info@gema.eu.com

Table of contents General safety regulations 3 Safety symbols (pictograms)... 3 Proper use... 3 Product-specific safety measures... 4 OptiAir CA09 Pneumatic-fluidizing unit... 4 About this manual 5 General information... 5 Function description 7 Field of application... 7 Structure... 8 Overview... 8 Technical data 9 OptiAir CA09 Pneumatic-fluidizing unit... 9 Pneumatic data... 9 Electrical data... 9 Dimensions... 9 Start-up and operation 11 Setting the fluidization... 11 Connect the powder hopper Airmover... 11 Spare parts list 13 Ordering spare parts... 13 OptiAir CA09 Pneumatic-fluidizing unit - spare parts... 14 OptiAir CA09 Pneumatic-fluidizing unit - spare parts... 15 Hose connections... 16 OptiAir CA09 Table of contents 1

General safety regulations Safety symbols (pictograms) This chapter sets out the fundamental safety regulations that must be followed by the user and third parties using the OptiAir CA09 Pneumaticfluidizing unit. These safety regulations must be read and understood before the OptiAir CA09 is put into operation. The following warnings with their meanings can be found in the Gema Switzerland operating instructions. The general safety precautions must also be followed as well as the regulations in the operating instructions. DANGER! Danger due to electrically live or moving parts. Possible consequences: death or serious injury WARNING! Improper use of the equipment could damage the machine or cause it to malfunction. Possible consequences: minor injuries or damage to equipment INFORMATION! Useful tips and other information Proper use 1. The OptiAir CA09 Pneumatic-fluidizing unit is built to the latest specification and conforms to the recognized technical safety regulations and is designed for the normal application of powder coating. 2. Any other use is considered non-compliant. The manufacturer shall not be liable for damage resulting from such use; the user bears sole responsibility for such actions. Gema Switzerland GmbH must be consulted prior to any use of the OptiAir CA09 for any purposes or substances other than those indicated in our guidelines. OptiAir CA09 General safety regulations 3

3. Observance of the operating, service and maintenance instructions specified by the manufacturer is also part of conformity of use. The OptiAir CA09 should only be used, maintained and started up by trained personnel informed about and familiar with the possible hazards involved. 4. Start-up (i.e. the execution of a particular operation) is forbidden until it has been established that the OptiAir CA09 Pneumaticfluidizing unit has been set up and wired according to the guidelines for machinery (2006/42 EG). EN 60204-1 (machine safety) must also be observed. 5. Unauthorized modifications to the OptiAir CA09 exempt the manufacturer from any liability from resulting damage. 6. The relevant accident prevention regulations, as well as other generally recognized safety regulations, occupational health and structural regulations are to be observed. 7. Furthermore, the country-specific safety regulations also must be observed. Explosion protection Protection type Temperature class II 3D IP54 T4 (Zone 22) Product-specific safety measures OptiAir CA09 Pneumatic-fluidizing unit The OptiAir CA09 pneumatic/fluidizing unit is a constituent part of the system and is thus integrated into the safety system of the plant. If it is to be used in a manner outside the scope of the safety concept, then corresponding measures must be taken. NOTE: For further information, see the more detailed Gema safety regulations! 4 General safety regulations OptiAir CA09

About this manual General information This operating manual contains all the important information you require for the working with the OptiAir CA09 Pneumatic-fluidizing unit. It will safely guide you through the start-up process and give you references and tips for the optimal use of your new powder coating system. Information about the functionality of the individual system components - booth, gun control unit, manual gun or powder injector - should be referenced to their enclosed corresponding documents. DANGER: Working without operating instructions Working without operating instructions or with individual pages from the operating instructions may result in damage to property and personal injury if relevant safety information is not observed. Before working with the device, organize the required documents and read the section "Safety regulations". Work should only be carried out in accordance with the instructions of the relevant documents. Always work with the complete original document. OptiAir CA09 About this manual 5

Function description Field of application The OptiAir CA09 Pneumatic-fluidizing unit regulates the fluidizing air and Airmover pressure. The fluidization operates directly by connecting the OptiAir CA09 Pneumatic-fluidizing unit to the compressed air. When using the OptiAir CA09 Pneumatic-fluidizing unit, the fluidizing air and the air to the Airmover will be regulated separately. The prefluidization is controlled automatically by the inserted solenoid valve (the signal comes from the PLC, OptiControl CM22 etc.). The exact prefluidization pressure can be set with the pressure regulator in the OptiAir CA09 Pneumatic-fluidizing housing. The prefluidization starts immediately by switching on the interlocking control unit. The OptiAir CA09 control unit is suitable particularly in combination with the Gema OptiMatic 2 series. OptiAir CA09 Function description 7

Structure Overview 2 4 1 3 1 Pressure regulator for fluidizing air 3 Pressure regulator for Airmover 2 Pressure indicator for fluidizing air 4 Pressure indicator for Airmover OptiAir CA09 Pneumatic-fluidizing unit - structure 8 Function description OptiAir CA09

Technical data OptiAir CA09 Pneumatic-fluidizing unit Pneumatic data OptiAir CA09 Input pressure Compressed air consumption Water vapor content Oil content Electrical data OptiAir CA09 Input voltage (according to the valve coil) Dimensions OptiAir CA09 Width Height Depth Weight 6-8 bar depending on the powder hopper size max. 1.3 g/m³ max. 0.1 mg/m³ 24 VDC 24 VAC / 50/60Hz 230 VAC / 50/60Hz 173 mm 177 mm 290 mm 3.4 kg OptiAir CA09 Technical data 9

Start-up and operation Setting the fluidization The powder fluidization depends on the powder type, the air humidity and the ambient temperature. The OptiAir CA09 Pneumatic-fluidizing unit contains pressure regulators and manometers for fluidizing air and Airmover. The OptiAir CA09 Pneumatic-fluidizing unit is connected to a 6-8 bar compressed air circuit. The fluidization is set as follows: 1. Connect the main compressed air supply and open it. The compressed air flows now through the OptiAir CA09 Pneumaticfluidizing unit. The fluidization operates immediately when connecting the OptiAir CA09 Pneumatic-fluidizing unit to the compressed air 2. Adjust the compressed air to 6 bar on the pressure reducing valve 3. Check the powder fluidization in the powder hopper. The compressed air of the prefluidization will "loosen up" the powder. This compressed air is controlled externally. If the powder begins to "boil", adjust the fluidizing air with the corresponding pressure regulator in such a way that the "boiling" spreads evenly on the powder surface. The fluidizing air pressure is monitored on the pressure gauge Connect the powder hopper Airmover The fluidizing air produces an overpressure in the powder hopper. This overpressure prevents the powder supply and must be eliminated. For this purpose an Airmover is installed on the powder hopper, which extracts, similarly as an injector, the overpressure and the powder mixed with air. Therefore, the Airmover produces a depression in the powder hopper. The air volume, which can be extracted by the Airmover, depends on the powder hopper size and the fluidizing air volume. The Airmover air is to be set, when a powder cloud rises over the powder surface and flows out through the powder hopper openings. The Airmover pressure is set with the corresponding adjusting button and monitored on the manometer. The pressure will be increased so far, until no more powder flows out of the powder hopper. OptiAir CA09 Start-up and operation 11

If these settings are once fixed, they can be left also when work interruptions take place. A reset of the adjusted values is thereby not necessary. The main switch of the OptiFlex A2 Control system can be switched on now, and the guns can be set and/or operated (see therefore the powder gun and gun control unit manuals). 4 5 3 1 2 1 Compressed air connection 4 Pressure regulator 2 Fluidizing air connection to the 5 Booster powder hopper 3 Output to the Airmover OptiAir CA09 - Airmover connection (rear view) 12 Start-up and operation OptiAir CA09

Spare parts list Ordering spare parts When ordering spare parts for powder coating equipment, please indicate the following specifications: - Type and serial number of your powder coating equipment - Order number, quantity and description of each spare part Example: - Type OptiAir CA09 Pneumatic-fluidizing unit Serial number 1234 5678 - Order no. 203 386, 1 piece, Clamp - Ø 18/15 mm When ordering cable or hose material, the required length must also be given. The spare part numbers of this bulk stock is always marked with an *. Wearing parts are always marked with a #. All dimensions of plastic hoses are specified with the external and internal diameter: Example: Ø 8/6 mm, 8 mm outside diameter (o/d) / 6 mm inside diameter (i/d) WARNING! Only original Gema spare parts should be used, because the explosion protection will also be preserved that way. The use of spare parts from other manufacturers will invalidate the Gema guarantee conditions! OptiAir CA09 Spare parts list 13

OptiAir CA09 Pneumatic-fluidizing unit - spare parts OptiAir CA09 Pneumatic-fluidizing unit - complete 1009 110 3 Front frame - complete 1007 048 4 Pressure regulator 0.1-4 bar, G1/4" 1009 101 5 Plug cap - 1/8"a 258 687 6 Elbow joint - 1/4"a, Ø 6 mm 265 691 7 Pressure gauge - 0-6 bar, 1/8"a 1003 300 8 Connection sleeve - 1/8"i, Ø 6 mm 233 412 9 Connection fitting - 3/8"a-3/8"a 202 975 10 Booster - 0-8 bar (without valve coil) 1007 561 10.1 Valve coil (for pos. 10) - 24 VDC (for the control by CM22, PLC etc.) (not shown) 257 990 Valve coil (for pos. 10) - 230 VAC, 50/60 Hz (not shown) 258 016 10.2 Connecting cable for pos. 10.1-5 m (not shown) 371 173 12 Screw-in nipple - 3/8"a, Ø 10 mm 242 268 13 Double nipple - 1/8"a-1/8"a 202 258 14 Pressure regulator - 0-8 bar, 1/8" 239 623 15 Elbow joint - 1/8"a, Ø 6 mm 254 061 16 Connection sleeve - 3/8"i, Ø 10 mm 259 349 17 Lead-through connection - Ø 6 mm, Rapid 241 792 Nut with kink protection for pos. 17 (not shown) 201 316 Plastic tube - Ø 8/6 mm, for pos. 17 (not shown) 103 756* * Please indicate length 14 Spare parts list OptiAir CA09

OptiAir CA09 Pneumatic-fluidizing unit - spare parts 10 15 15 13 14 15 17 12 9 8 7 6 16 3 5 4 15 6 OptiAir CA09 Pneumatic-fluidizing unit - spare parts OptiAir CA09 Spare parts list 15

Hose connections 1 Plastic hose - Ø 6/4 mm, black 103 144* 2 Plastic hose - Ø 10/8 mm, black 103 250* * Please indicate length OptiAir CA09 Pneumatic-fluidizing unit - hose connections 16 Spare parts list OptiAir CA09

OptiAir CA09 Spare parts list 17