Gas Furnaces 95AF. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited. 95% AFUE 44,000 to 110,000 Btuh Input 2 to 5 Tons Add-On Cooling
|
|
- Bryan Atkinson
- 5 years ago
- Views:
Transcription
1 PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel tapered design primary heat exchanger with crimped construction for long life Stainless steel secondary heat exchanger Flue Condensate Trap furnished 95% AFUE 44,000 to 0,000 Btuh Input 2 to 5 Tons Add-On Cooling Upflow / Horizontal BURNERS Aluminized steel inshot burners for smooth combustion CABINET CONSTRUCTION Unitized construction for cabinet integrity Bottom or side return air Baked on pre-painted steel cabinet finish Left or right side gas and electric entry BLOWER Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency Counterflow CONTROLS Single stage gas valve Integrated ignition and fan control board features self diagnostics Hot surface ignitor VENTING One or two pipe venting ready Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited
2 Model Number Identification 95 = AFUE AF = Aire-Flo = -Stage UH = Upflow / Horizontal DF = Counterflow Heat Input 045 = 45,000 Btuh 070 = 70,000 Btuh 090 = 90,000 Btuh 0 = 0,000 Btuh 95 AF UH 045 P 08 B Cabinet Width B = 7-/2 in. C = 2 in Nominal Airflow 08 = 800 cfm 2 = 200 cfm 6 = 600 cfm 20 = 2000 cfm P = PSC Direct Drive Blower Motor Specifications UH045P08B UH070P2B UH090P2C UH090P6C UH0P20C Upflow / Horiz. Upflow / Horiz. Upflow / Horiz. Upflow / Horiz. Upflow / Horiz. Input Btuh 44,000 66,000 88,000 88,000 0,000 Output Btuh 4,000 64,000 85,000 85,000 06,000 AFUE (Isolated Comb. System) 95.0% 95.0% 95.0% 95.0% 95.0% Temperature Rise ( F) Gas Pipe Size (in.) /2 /2 /2 /2 /2 Inlet/Vent Connection in. (diameter) Condensate Drain Trap (PVC) - i.d. Volts/Hertz/Phase 20/60/ 20/60/ 20/60/ 20/60/ 20/60/ Blower Motor Horsepower /5 /3 /3 /2 Add-On Cooling (tons) Circuit Breaker or Fuse Full Load Amps Blower Wheel Size (Dia. x Width) 0 x 8 0 x 8 0 x 8 0 x 0 ½ x 0 Shipping Weight (lbs.) DF045P2B DF070P2B DF090P20C Counterflow Counterflow Counterflow Input Btuh 44,000 66,000 88,000 Output Btuh 43,000 64,000 86,000 AFUE (Isolated Comb. System) 95.0% 95.0% 95.0% Temperature Rise ( F) Gas Pipe Size (in.) /2 /2 /2 Inlet/Vent Connection in. (diameter) Condensate Drain Trap (PVC) - i.d. Volts/Hertz/Phase 20/60/ 20/60/ 20/60/ Blower Motor Horsepower /3 /3 /2 Add-On Cooling (tons) Circuit Breaker or Fuse Full Load Amps Blower Wheel Size (Dia. x Width) 0 x 8 0 x 8 0 x 0 Shipping Weight (lbs.)
3 Accessories UH045P08B UH070P2B UH090P2C UH090P6C UH0P20C Gas Furnaces DF045P2B DF070P2B DF090P20C Upflow / Horiz. Upflow / Horiz. Counterflow Counterflow CABINET Combustible Flooring Base (Counterflow) M60 M6 Horizontal Suspension Kit (Horizontal) 5W0 5W Return Air Base (Upflow) 50W98 50W DRAIN KIT Condensate Drain Heat Cable 6 ft. 26K68 26K68 26K68 26K68 24 ft. 26K69 26K69 26K69 26K69 50 ft. 26K70 26K70 26K70 26K70 Heat Cable Tape Fiberglass ½ in. x 66 ft. 36G53 36G53 36G53 36G53 Alum. Foil 2 in. x 60 ft. 6P89 6P89 6P89 6P89 Crawlspace Vent Drain Kit 5W8 5W8 5W8 5W8 FILTER KITS Air Filter and Horizontal (end) 87L96 (8 x 25 x ) 87L97 (20 x 25 x ) Rack Kit (Upflow/ Side Single 44J22 44J Horizontal Return 0-pack 66K63 66K (Upflow) Size 6 x 25 x 6 x 25 x Air Filter and Rack Kit (Counterflow) W07 (2) 20 x 20 x 5W08 (2) 20 x 20 x GAS HEATING Natural to LP Conversion Kit ft. 69W73 69W73 69W73 69W73 LP to Natural Conversion Kit ft. 73W8 73W8 73W8 73W8 High Altitude Pressure No change (045) 93W92 (090) No change (045) ft. Switch Kit 93W93 (070) 93W93 (0) 93W93 (070) 93W92 (090) 750-0,000 ft. 93W87 (045) 93W87 (045) 93W86 93W86 (070) 93W86 (070) 93W86 Natural Gas High Altitude Orifice Kit 750-0,000 ft. 73W37 73W37 73W37 73W37 LP High Altitude Orifice Kit 750-0,000 ft. 68W68 68W68 68W68 68W K Derate Kit (Natural Gas) 0-0,000 ft. 0K55 (045) K55 (045) NIGHT SERVICE KIT Night Service Kit 68W80 68W80 68W80 68W80 VENTING Concentric Vent Kit 2 in. (US) 7M80 69M29 7M80 69M29 3 in. (US) L L46 2 in. (Canada) 44W92 44W92 44W92 44W92 3 in. (Canada) W W93 Flush Mount 2, 2-/2 or 3 in. (US) 5W 5W 5W 5W 2, 2-/2 or 3 in. (Canada) 5W2 5W2 5W2 5W2 Wall - Close 2 in. (US) 22G G Couple 3 in. (US) 44J40 44J40 44J40 44J40 Wall - Close Couple WTK 2 in. (Canada) 30G G in. (Canada) 8J20 8J20 8J20 8J20 Roof 2 in. 5F75 5F75 5F75 5F75 Wall Ring Kit 2 in. 5F74 3 5F74 5F74 3 5F74 3 Flashing Kit 2 in. 44J4 44J4 44J4 44J4 Cleanable polyurethane frame type filter. 2 NOTE - 36K Derate Kit information - Reduced Input is 36,000 Btuh, output is 34,200 Btuh. 3 Kits contain enough parts for two, non-direct vent installations. 4 Non-direct vent only. NOTE - Termination Kits 44W92, 44W93, 30G28, 5W2, 8J20 are certified to ULC S636 standard for use in Canada only.
4 Blower Data UH045P08B (Upflow / Horizontal) UH070P2B (Upflow / Horizontal) UH090P2C (Upflow / Horizontal) UH090P6C (Upflow / Horizontal) UH0P20C (Upflow / Horizontal) Single Side Return Air - Air volumes in bold require field fabricated transition to accommodate 20 x 25 x in. air filter in order to maintain proper air velocity. Bottom Return Air, Side Return Air with Optional Return Air Base, Return Air from Both Sides or Return Air from Bottom and One Side. DF045P2B (Counterflow) DF070P2B (Counterflow) DF090P20C (Counterflow) Blower Speed External Static Pressure - in w.c. Less Filter High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low High Med/High Med/Low Low Notes: Maximum approved external static pressure is 0.50 in. w.c.
5 Clearance to Combustibles (in.) Sides 0 Rear 0 Top/Plenum Front 0 Front (service/alcove) 24 Floor 2 Combustible NOTE Air for combustion must conform to the methods outlined in the National Fuel Gas Code (NFPA 54/ANSI-Z223.) or the National Standard of Canada CAN/CSA-B49. Natural Gas and Propane Installation Code. NOTE In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFPA 54/ ANSI-Z223.) or applicable provisions of local building codes. In Canada flue sizing must conform to the methods outlined in National Standard of Canada CAN/CSA-B49.. Allow proper clearances to accommodate condensate trap and vent pipe installation. 2 Do not install the furnace directly on carpeting, tile, or other combustible materials other than wood flooring.
6 Vent Lengths - Feet - Upflow / Horizontal NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must be same pipe size. STANDARD TERMINATION AT ELEVATION ft. Pipe Size 2 in. 2-/2 in. 3 in. Input N/A No. of N/A N/A elbows N/A used N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A STANDARD TERMINATION AT ELEVATION 450-0,00 ft. Pipe Size 2 in. 2-/2 in. 3 in. Input N/A N/A N/A No. of N/A N/A elbows N/A used N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CONCENTRIC TERMINATION ELEVATION ft. Pipe Size 2 in. 2-/2 in. 3 in. Input N/A No. of N/A N/A elbows N/A N/A used N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CONCENTRIC TERMINATION ELEVATION ,000 ft. Pipe Size 2 in. 2-/2 in. 3 in. Input No. of 90 elbows used N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
7 Vent Lengths - Feet - Counterflow NOTE - Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and Exhaust must be same pipe size. STANDARD TERMINATION AT ELEVATION 0-0,000 ft. Pipe Size 2 in. 2-/2 in. 3 in. Input N/A N/A N/A N/A N/A N/A N/A No. of N/A N/A N/A N/A N/A N/A elbows N/A N/A N/A used 7 26 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A CONCENTRIC TERMINATION ELEVATION 0-0,000 ft. Pipe Size 2 in. 2-/2 in. 3 in. Input No. of 90 elbows used N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
8 Dimensions - inches (mm) Upflow NOTE - 20C size units that require air volumes over 800 cfm must have one of the following:. Single side return air with transition, to accommodate 20 x 25 x in. cleanable air filter. Required to maintain proper air velocity. 2. Single side return air with Optional Return Air Base 3. Bottom return air. 4. Return air from both sides. 5. Bottom and one side return air. See Blower Performance Tables for additional information. 2 Optional Side Return Air Filter Kit is not for use with the Optional Return Air Base. 2 (5) D COMBUSTION INTAKE 3-3/8 (86) 2-7/8 (73) EXHAUST OUTLET SUPPLY OPENING Flue Condensate Trap Assembly Furnished for external field installation on either side of unit. (See installation instructions for additional information.) 7 (78) 2 OPTIONAL SIDE RETURN FILTER KIT 23- (603) 25 (635) TOP VIEW A B Front Panel 27- (705) 9-7/6 (494) 2 OPTIONAL SIDE RETURN FILTER KIT 4- (375) 6 (406) 33 (838) 6- (67) Left 9 (229) Right 2-5/8 (32) ELECTRICAL INLET 2 (5) GAS PIPING INLET CONDENSATE TRAP CONNECTION 6-/2 (65) 23 (584) Side Return Air Opening 4 (356) -/2 (38) FLOW -5/6 (49) C Bottom Return Air Opening 5/8 (6) 3-/4 (83) 23-/2 (597) Bottom Return Air Opening FRONT VIEW SIDE VIEW UH045P08B UH070P2B UH090P2C UH090P6C UH0P20C A B C D in. mm in. mm in. mm in. mm 7-/ / / / / /8 238
9 Dimensions - inches (mm) Horizontal LEFT-HAND DISCHARGE 6-/2 (65) Bottom 2-5/8 (32) Bottom 6- (67) Top 9 (229) Bottom CONDENSATE TRAP CONNECTION (Bottom) FLOW ELECTRICAL INLET (Top or Bottom) 27- (705) 2 (5) Top or Bottom COMBUSTION INTAKE TOP VIEW 33 (838) GAS PIPING INLET (Top or Bottom) 27- (705) B 9-7/6 (494) SUPPLY OPENING 2-7/8 (73) D A FLOW 3-/4 (95) A C 23-/2 (59) RETURN OPENING EXHAUST OUTLET END VIEW 3-3/8 (86) 2 (5) FRONT VIEW RIGHT-HAND DISCHARGE END VIEW Front Panel CONDENSATE TRAP CONNECTION (Bottom) FLOW 6-/2 (65) Bottom 2-5/8 (32) Bottom 9 (229) Top 6- (67) Bottom 2 (5) Top or Bottom 27- (705) ELECTRICAL INLET (Top or Bottom) TOP VIEW 33 (838) GAS PIPING INLET (Top or Bottom) EXHAUST OUTLET 2 (5) 3-3/8 (86) 27- (705) 23-/2 (59) RETURN OPENING C 3-/4 (95) A FLOW A D 2-7/8 (73) 9-7/6 (494) SUPPLY OPENING B END VIEW FRONT VIEW COMBUSTION INTAKE END VIEW UH045P08B UH070P2B UH090P2C UH090P6C UH0P20C A B C D in. mm in. mm in. mm in. mm 7-/ / / / / /8 238
10 Dimensions - in. (mm) Counterflow Flue Condensate Trap Assembly Furnished for external field installation on either side of unit. (See installation instructions for additional information.) 7 (78) COMBUSTION INTAKE EXHAUST OUTLET 2-/6 (52) B RETURN OPENING 5 (27) 2-/4 (57) TOP VIEW A B FLOW Front Panel 27- (705) 9-7/6 (494) 33 (838) 2 (5) Either Side GAS PIPING INLET ELECTRICAL INLET CONDENSATE TRAP CONNECTION 9-/8 (232) Right 6- (67) Left 6-7/6 (63) Either Side 9 (229) Either Side C Supply Air 9-/4 (489) Supply Air FRONT VIEW SIDE VIEW DF045P2B DF070P2B A B C in. mm in. mm in. mm 7-/ / DF090P20C / /2 495
11
12 Revisions Sections Accessories/Gas Heating Description of Change Added 36K Derate Kit (05/3) Aire-Flo Heating and Cooling, 203
Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited
PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel primary heat exchanger with crimped non-welded construction Stainless steel
More informationRuud Achiever Series Highboy & Lowboy Oil Furnaces with ECM/Variable Speed Motors
THIS MODEL 80.0% 78% 82% 88% 97% Oil Furnaces Ruud Achiever Series Highboy & Lowboy Oil Furnaces with ECM/Variable Speed Motors ROCA-***E: Highboy Series ROLA-***E: Lowboy Series Input Ratio from 84,000
More informationThe conversion of new certified central heating gas appliances must conform to directions outlined in this instruction.
ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION MID-EFFICIENCY SINGLE-STAGE INDUCED COMBUSTION FURNACES MODELS: P*HU/G8T-UH/L8T-UH/FL8 UPFLOW / HORIZONTAL P*DN/G8T-DN/L8T-DN
More informationYour safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT ALPKT57- INSTALLATION INSTRUCTIONS PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements... Table of Contents INSTALLATION
More informationFMU4X, FMC4X FMU4P, FMC4P
ENVIRONMENTALLY SOUND REFRIGERANT FMU4X, FMC4X FMU4P, FMC4P Product Specifications HORIZONTAL FAN COILS FMU4P and FMC4P 1 1/2, 2, 2 1/2, and 3 Tons FMU4X and FMC4X 1 1/2, 2 and 2 1/2 Tons ALL MODELS Horizontal
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS 1NP0680 - PROPANE CONVERSION FOR USE WITH MODELS: PM8, PC8, PM9, PC9, FL9M, FL9C, FC9M, FC9C This conversion kit is to be installed by a qualified service agency
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW, DOWNFLOW, UPFLOW/HORIZONTAL & HORIZONTAL ONLY INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0501 FOR USE WITH 95% MODELS: TG9S, GG9S (130,000 BTU ONLY) FOR USE WITH 80% MODELS: TG(8,L)S, GG(8,L)S (130,000
More informationNatural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet)
Natural Gas High-Altitude Conversion Kit For Installations in the United States (2,001 10,000 Feet) INSTALLATION INSTRUCTIONS For R7 Series Light Commercial Packaged Gas Electric Units IIMPORTANT: Please
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS HIGH ALTITUDE APPLICATION CONVERSION INSTRUCTION HIGH EFFICIENCY GAS FURNACES 1PS0306 / 1PS0307 / 1PS0308 / 1PS0309 / 1PS0901 / 1PS0902 / 1PS0903 FOR USE WITH MODELS:
More informationRequired Indoor Draft Hood. Optional Outdoor Vent Cap
Pump-Mounted Water Heaters B4 - Copper Brute Water Heater Convertible Sizes 175,000-399,000 BTU/hr Indoor/Outdoor Sizes 500,000-1,825,000 BTU/hr Up to 82% Thermal Efficiency The unit will be designed and
More informationInstallation Instructions
48011HW NATURAL GAS TO PROPANE CONVERSION KIT 58HDX, 359AAV, PG9YAB, PG9YAA Installation Instructions SAFETY REQUIREMENTS Installing and servicing heating equipment can be hazardous due to gas and electrical
More informationGAS SUPPLY APPLICATION GUIDE
GAS SUPPLY APPLICATION GUIDE Natural Gas or Propane Modulating & Condensing Boilers and Water Heaters This document applies to the following models: Boilers AM 399B AM 500B AM 750B AM 1000B Gas-Fired Boilers
More informationGAS SUPPLY DESIGN GUIDE
GAS SUPPLY DESIGN GUIDE Natural Gas, Propane Gas, or Dual Fuel Fired Modulating, Condensing Boilers BENCHMARK Series Gas-Fired Boilers For models: BMK750 to BMK6000 Last Update: 06/20/2014 PR1 06/20/14
More informationNatural Gas to L.P. Gas Conversion Kit
Natural Gas to L.P. Gas Conversion Kit For Bosch 80% AFUE Gas Furnace, BGS80 Model Installation Instructions 3124627 2 Natural Gas to L.P. Gas Conversion Kit Installation Instructions Data subject to change
More informationAIR CONDITIONERS WA14**W SERIES
FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationNatural Gas to L.P. Gas Conversion Kit
Natural Gas to L.P. Gas Conversion Kit For Bosch 96% AFUE Gas Furnace, BGH96 Model Installation Instructions 3124627 2 Natural Gas to L.P. Gas Conversion Kit Installation Instructions Data subject to change
More informationWARNING: Installation Instructions. Natural Gas High Altitude Conversion Kit United States Installations Only
Natural Gas High Altitude Conversion Kit United States Installations Only Installation Instructions Light Commercial Packaged Gas Electric Units R7TQ Series 6, - 7 1/2, & 10 Ton (2,001 FT - 10,000 FT)
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Propane Gas Conversion Kit WGCK-1 Instructions for 0-6,000 Feet Elevation Installations This propane gas conversion kit is to be used only when converting the following furnace
More informationinstallation instructions
installation instructions GAS CONVERSION KIT PROPANE-TO-NATURAL P/N 315572-71201 4GAD 6GAD Cancels: IIK 4G-50-4 IIK 4G-50-5 7/15/91 NOTE: Read the entire instructions before starting the installation.
More informationLENNOX SLP98UHV DIAGNOSTIC CODES
Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second
More informationMAINLINE MLA14 AIR CONDITIONERS
FORM NO. AML-220 Supersedes Form No. PTZ-789 MAINLINE AIR CONDITIONERS Efficiencies up to 16 /13 Nominal Sizes 1.5-5 Ton [5.28 TO 17.6 KW] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7 kw] Manufactured
More informationWARNING: Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings FOR YOUR SAFETY
Form CP-UD-GC Obsoletes I-UD-GC (Version E) Gas Conversion Kit Instructions Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters General and Warnings All gas conversion must be done by a qualified
More informationAIR CONDITIONERS WA14 SERIES
FORM NO. A66-220 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS PROPANE TO NATURAL GAS CONVERSION KIT NAHA00801NG or PART NO. 1183389 TABLE OF CONTENTS Safety Considerations... 1 Introduction... 1 Description and Usage... 2 Induced Combustion,
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-220 Supersedes Form No.
FORM NO. AFJ-220 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*14C SERIES Efficiencies up to 16 S/13 Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to 17.7
More informationINSTALLATION GUIDE Gas Rangetops
INSTALLATION GUIDE Gas Rangetops Contents Wolf Gas Rangetops........................... 3 Safety Instructions............................ 4 Gas Rangetop Specifications.................... 5 Gas Rangetop
More informationKC Series Gas Components and Supply Design Guide
Technical Bulletin KC Series Gas Components and Supply Design Guide GF-1030 General AERCO KC Series gas fired potable water heaters and boilers are modulating input devices that require an adequate volume
More informationPropane Conversion Kit Instruction
Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates Logamax plus GB62-80 kw 270,000 btu/hr Logamax plus GB62-00 kw 35,000 btu/hr This kit and instructions are for converting the
More informationModulating Valves for Atmospheric, Infrared, and Direct Fired Burners
BULLETIN MT2035-07/05 Modulating Valves for Atmospheric, Infrared, and Direct Fired Burners M/MR Series M411, M511, M611 M420, M520, M620, MR410, MR510, MR610 MR212D, MR212E, MR212G and MR212J (Flanged),
More informationField Installed Options: * Louvered or non-louvered ceiling access panels. * Time delay relay.
Description: The High Efficiency Series air handlers are engineered to achieve or exceed today s demanding energy rating requirements. Specifically designed for horizontal mounting into a furred down ceiling.
More informationACCESSORY KIT INSTALLATION MANUAL
ACCESSORY KIT INSTALLATION MANUAL LP (PROPANE) CONVERSION KIT 1NP0366 FOR USE WITH MODELS: G8C & GF8 This conversion kit shall be installed by a qualified service agency in accordance with these instructions
More informationTWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3
TWC Services, Inc. Structured On-The-Job Training for JT- 1, 2, 3 The following tasks parallel the Jr. Tech (JT-1, 2, 3) description and development plan and use the Refrigeration and Air conditioning
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationNorth American Orifice Metering System
Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual
More informationM/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners
M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...
More informationIf you want to offer a more professional look to your
Model RT366 Model RT364C Low profile island trim 11" (279) griddle (optional) Porcelain coated cast iron top grates Dual brass burners 36" GAS RANGETOPS Model RT364G Stainless steel exterior finish Large
More informationGAS KITS & ACCESSORIES 504,986M 11/2004 HIGH ALTITUDE KIT
LENND 2004 Lennox Industries Inc. DaItas, Texas, USA GAS KITS & ACCESSORIES Litho U.S.A. 504,986M 11/2004 HIGH ALTITUDE KIT INSTALLATION INSTRUCTIONS FOR HIGH ALTITUDE KIT (83M75) USED WITH G43UF & G51MP
More informationINSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1*
INSTRUCTIONS FOR CONVERTING CONDENSING GAS MOBILE HOME FURNACES MODEL SERIES: CMA3*, CMC1*, VMA3*, VMC1* THIS KIT CONTAINS: AOPS7741 (NATURAL TO PROPANE CONVERSION PARTS FOR MODEL SIZE, 50) AOPS7742(NATURAL
More informationInstallation Operation Maintenance
682 Seal Cooler New generation seal cooler to meet and exceed the seal cooler requirements stated in the 4th Edition of API Standard 682 Installation Operation Maintenance Experience In Motion Description
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-222 Supersedes Form No.
FORM NO. AFJ-222 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*16C SERIES Efficiencies up to 16 SEER/13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7 to
More informationPropane Conversion Kit Instruction
Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates GB142-24 84,800 btu/hr GB142-30 106,000 btu/hr GB142-45 160,900 btu/hr GB142-60 214,800 btu/hr This kit and instructions are
More informationPropane Conversion Kit Instruction
Propane Conversion Kit Instruction Condensing gas boiler Required Input Rates GB42-24 84,800 btu/hr Tab. GB42-30 06,000 btu/hr GB42-45 49,000 btu/hr GB42-60 24,800 btu/hr This kit and instructions are
More informationIf you want to offer a more professional look to your
Infrared griddle (optional) Porcelain-coated cast iron top grates Model RT366 Low-profile island trim Dual brass burners Model RT364C Location of rating plate Model RT364G Stainless steel exterior finish
More informationAIR CONDITIONERS. Features. Manufactured for Fujitsu General America, Inc. Fairfield, NJ. FORM NO. AFJ-221 Supersedes Form No.
FORM NO. AFJ-221 Supersedes Form No. PTZ-789 AIR CONDITIONERS FO*13C SERIES Efficiencies 13-15.5 SEER/11.5-13 EER Nominal Sizes 1 1 /2 to 5 Ton [5.28 to 17.6 kw] Cooling Capacities 17.3 to 60.5 kbtu [5.7
More informationPumpAgents.com - Click here for Pricing/Ordering Nominal psi (bar) Cut-In Cut-Out
PumpAgents.com - Click here for Pricing/Ordering Model 31670-Series Dual Max 7.5 GPM (28 LPM) AUTOMATIC TWO STAGE WATER SYSTEM WITH ACCUMULATOR TANK AND PUMPGARD STRAINER IDEAL FOR PLEASURE AND COMMERCIAL
More informationGas Appliance Venting Products
Gas Appliance Venting Products Natural or Propane Gas fired appliances only Appliance Category tells us what venting products you are allowed to use Appliance Category can be found on label and in the
More informationProduct Data. FA4A FB4A FC4B Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest
Product Data FA4A FB4A Direct Expansion Fan Coil Sizes 018 thru 070 Air Handling Technology At Its Finest Carrier s FA4A, FB4A, and direct expansion multipoise fan coils are designed to cover a wide range
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347
ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,
More informationUser s Information Manual
48HC with EnergyX R System Factory Installed Energy Recovery Single---Package Rooftop Unit (RTU) Gas Heating/Electric Cooling Units 15 to 25 Nominal Tons with Puronr (R---410A) Refrigerant User s Information
More informationFXT. FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS
FXT FXT Cooling Tower RIGGING & ASSEMBLY INSTRUCTIONS FXT Cooling Towers should be rigged and assembled as outlined in this bulletin. These procedures should be thoroughly reviewed prior to the actual
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationTECHNICAL DATA. Trimpac 244a. September 16, 2013
September 16, 2013 Trimpac 244a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-1 and B-1B is a factory-assembled trim package with an electric release module in a metal enclosure. The standard trim normally
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS
ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,
More informationInstallation Instructions For Natural Gas Conversion
Installation Instructions For Natural Gas Conversion (Kit Part No. 1175405) This kit is designed to convert PGX4 and PX4 Two -Stage Gas units for use with Natural Gas. Table 1 Heating Value at Altitude
More informationMAXON M-PAKT ULTRA LOW NOx BURNERS
ULTRA LOW NOx BURNERS TECHNICAL CATALOG 3M-0007-0 TABLE OF CONTENTS Product description... 3 Features and benefits... 3 Typical emissions... 3 Model Numbers... Specifications of M-PAKT Burners... Materials
More informationINSTALLATION INSTRUCTIONS
INSTALLATI INSTRUCTIS For Natural Gas to Propane Conversion Kit Model No: NAHA001LP or Part No. (1172958) CVERT Series BTUH N8MPN/L B 50, 75, 100, 125 *8MPN/L B 50, 75, 100, 125 *8MPN B 150 *8DNL B 50,
More informationTECHNICAL DATA. TRIMPAC Model B-5 & B-5B
September 16, 2013 Trimpac 250a 1. DESCRIPTION DEsCRIPTIoN is a factory assembled trim package for a ed an electric/pneumatic release module in a metal enclosure. The standard trim normally required on
More informationRemeha Quinta Cascade guide
Technical information Remeha Quinta Cascade guide Cascade guide Cascade systems 2 Remeha Quinta Cascade guide TABLE OF CONTENTS FOREWORD 4 1 GENERAL DESCRIPTION OF CASCADE SYSTEMS 4 1.1 Optimum number
More informationACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347
ACCESSORY KIT INSTALLATION INSTRUCTIONS PROPANE CONVERSION - INDUCED COMBUSTION FURNACES 1NP0347 FOR USE WITH 90% + MODELS: GF9S, GY9S, GM9S, PS9, FL9S, FC9S, PT9, FL9T, FC9T, GM9T, PV9, FL9V, FC9V, GM9V,
More informationLaars Combi Heat PV Gas Water Heater
RESIDENTIAL GAS REPLACEMENT PARTS LIST Laars Combi Heat PV Gas Water Heater Document 11040 Effective: September, 2006 ECO 6885 NOTE: BOTH MODEL AND SERIAL NUMBERS ARE REQUIRED FOR ORDERING REPLACEMENTS
More informationRPS900W Redundant Power Supply. Installation Guide.
RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A
More informationVR8205S,T Direct Ignition Combination Gas Controls
VR805S,T Direct Ignition Combination Gas Controls INSTALLATION INSTRUCTIONS APPLICATION TheVR805S,T Direct Ignition Combination Gas Controls are used in gas-fired appliances with up to 70 ft 3 /hr capacity
More informationTECHNICAL DATA. Trimpac 251a. Spetember 16, 2013
Spetember 16, 2013 Trimpac 251a 1. DEsCrIpTION DESCRIPTION TRIMPAC Model B-6 and B-6B is a factory assembled trim package for a double interlocked preaction system with an electric/pneu-lectric release
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS For Burner Kit replacement of 553010021 Burners in GUI, GDI & GNI Gas Furnaces Using Natural Gas Please read these instructions completely before attempting installation. SAFETY
More informationModel MTB-ASME Horizontal Bladder Tanks
DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure
More informationHorizontal Bladder Tanks
DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationProduct Data CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW DESIGN FEATURES
CAPVP, CARVP, CAPVU, CARVU EVAPORATOR COIL A COIL - CASED AND UNCASED UPFLOW, DOWNFLOW Product Data CAPVP / CARVP A06001 A06002 CAPVU / CARVU The CAPVP, CARVP, CAPVU, and CARVU evaporator coils incorporate
More informationFA4B FB4B FC4C DIRECT EXPANSION FAN COIL. Sizes 018 thru 070. Form No. PDS FA4B Air Handling Technology At Its Finest
DIRECT EXPANSION FAN COIL FA4B FB4B Sizes 018 thru 070 Air Handling Technology At Its Finest The FA4B, FB4B, and direct expansion fan coils are designed to cover a wide range of air handling requirements.
More informationELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS AIR CONDITIONERS EL16XC1 ELITE Series R-410A Bulletin 210758 November 2017 Supersedes August 2017 SEER up to 17.90 1.5 to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh MODEL NUMBER
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More information/2004 US/CA
630 9765 0/004 US/CA For the contractor Propane Conversion Kit Instructions Sealed Combustion Gas Boiler Logano GA44 This kit and instructions are for converting the GA44 model boilers from Natural Gas
More informationTECHNICAL DATA. Trimpac 257a. September 16, 2013
September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking
More informationInstallation Instructions For Propane Gas Conversion (Kit Part No ) This kit is designed for conversion to Propane Gas
Installation Instructions For Propane Gas Conversion (Kit Part No. 1173859) This kit is designed for conversion to Propane Gas Table 1 LP Gas Orifice Kits and Sizes Elevation Above Sea Level 0 to 2000
More informationTECHNICAL DATA. Trimpac 256a. October 31, 2013
October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve
More informationFeatures. Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes
Bulletin 357 Rev. E Model DDX-LP Dry Pipe Valve System 4 (100mm), 6 (150mm) & 165mm Sizes Bulletin 357 Rev. E Features 1. 2. 3. 4. 5. 6. 7. 8. 9. Differential-type valve, lightweight, dependable construction.
More informationTurbo Blowers. Combustion Excellence Since Features. Benefits
Turbo Blowers Features Integral molded scroll design Turbine bladed impeller Steel inlet guard Precisely balanced impellers eliminate vibration Complete line of available accessories for adapting to any
More informationGM Series Dual-Block Multi-Function Gas Control Valves
Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series
More informationProduct Data CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE CAPMP / CARMP CAPMP / CARMP (3619, 4823, 6025)
CAPMP, CARMP EVAPORATOR COIL A COIL - CASED MULTIPOISE Product Data (3619, 4823, 6025) A06009 A07904 The CAPMP and CARMP evaporator coils incorporate proven standards for reliable system operation and
More informationAir Operated Hydraulic Pumping Systems to 50,000 psi
High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air
More informationNorth American 7337A/B/C-4 High Pressure Gas Regulators
Combustion North American A/B/C-4 High Pressure Gas Regulators Bulletin A/B/C-4 A-4, B-4 and C-4 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the
More informationTECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1
Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a
More informationSpeciÞcations. Engine Dimensions Dimensions in millimeters. Inch equivalents shown in [].
SpeciÞcations Engine Dimensions Dimensions in millimeters. Inch equivalents shown in []. Ê ßÔ Ê ÛÝ Ñ Ê Û ÎÊ Û É 5 ENGINE IDENTIFICATION NUMBERS Kohler engine identiþcation numbers (model, speciþcation
More informationWorkhorse-15 Oxygen Generator
11436 Sorrento Valley Road, San Diego CA 92121 USA 858-558-0202 Fax 858-558-1915 Workhorse-15 Oxygen Generator Model No. 5719, 5727, 5735 for Domestic and International Units Part number 1432 Revision
More informationStandard Operating and Maintenance Instructions for Pumping System Model PS-90
Standard Operating and Maintenance Instructions for Pumping System Model PS-90 High Pressure Equipment Company 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075
More informationGas Countertop Hot Plates
Gas Countertop Hot Plates This manual contains important information regarding your Patriot unit. Please read the manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply
More informationHORIZONTAL BLADDER TANK
Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure
More informationVertical Bladder Tanks
DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationC645A-E Pressure Switches
C645A-E Switches FEATURES PRODUCT DATA C645A,B,D,E GENERAL C645A,B with Window C645C The C645 pressure switches are safety devices used in positive-pressure or differential-pressure systems to sense gas
More informationModel DDX-LP Dry Pipe Valve System 8 (200mm) Features. Differential latching clapper-type, lighweight, dependable construction.
Bulletin 335 Model DDX-LP Dry Pipe Valve System 8 (200mm) Bulletin 335 Features 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. Differential latching clapper-type, lighweight, dependable construction. Low Air Pressurized
More informationProduct Data. FA4B FB4B FC4C Direct Expansion Fan Coil. Sizes 018 thru 070. Air Handling Technology At Its Finest
Product Data FA4B FB4B Direct Expansion Fan Coil Sizes 018 thru 070 A02305 Air Handling Technology At Its Finest Carrier s FA4B, FB4B, and direct expansion multipoise fan coils are designed to cover a
More informationCHECK-VALVES Automatically Position Themselves by the Natural Forces of the Conveying Air. A PNEUMATIC CONVEYING SYSTEM PATENT #: 5,160,222
PATENT #: 5,160,222 PHONE: (913)677-5777 FAX: (913)677-067 E-Mail : techair@techairinc.com www.techairinc.com CHECK-KLEEN DIVERTER A PNEUMATIC CONVEYING SYSTEM FLAP-CHECKS exposed to product air stream
More informationInstallation Instructions
LP and High Altitude LP Gas Conversion Kit For United States Installations Installation Instructions For Model Series *G6/PGF1 Furnaces, *L1/PGC1 Furnaces, and *R4/PPG1 Gas/Electric Appliances using Honeywell
More information4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM ENHANCED AIR CONDITIONING DESIGN COMPONENTS WARRANTY COMPRESSOR CABINET COILS
PRODUCT SPECIFICATIONS 16 S SPLIT SYSTEM ENHANCED AIR CONDITIONING FORM NO. -100 (06/2014) DESIGN Designed for ambients up to 125 F COMPONENTS Service valves positioned for quick installation and easy
More informationGAS VALVE RETROFIT KIT Pull Through Tube Heater Models
GAS VALVE RETROFIT KIT Pull Through Tube Heater Models DESCRIPTION: This kit is designed to replace existing Honeywell gas valves #VR8205P and #VR8205Q with White-Rodgers gas valves #36J23 and #36J58 respectively
More informationVR8305 Direct Ignition Combination Gas Control
Honeywell VR8305 Direct Ignition Combination Gas Control Application These direct ignition combination gas controls are used in gas-fired appliances with capacities up to 300 feet 3 /hour at inch wc pressure
More informationLP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957
LP GAS PRODUCTS HIGH QUALITY GAS PRODUCTS SINCE 1957 Enerco, based in Cleveland Ohio, has been at the forefront of infrared technology since 1957. This market leading technology has allowed Enerco to build
More informationINSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS
INSTALLER! PLEASE LEAVE WITH HOMEOWNER INSTALLATION AND OPERATING INSTRUCTIONS BIG TEX VENTED GAS LOGS by Please Note: It is important that you read instructions before installing or operating gas logs
More informationQuick Reference Technical Data
Bulletin 127C 2 Quick Reference Technical Data For over 100 years, The Spencer Turbine Company has specialized in innovative solutions to air and gas handling problems. Spencer's product line includes
More information