1 MM-70 McDonnell & Miller Replacement Parts Catalog For Residential, Commercial and Industrial Applications

2 What you don t know about boiler controls... but should. Keep your customers safe, your reputation intact and your business strong by regularly inspecting and replacing boiler controls. Whether it s changing entire controls, or replacing heads or blow down valves, boiler control inspections and replacements aren t just good habits. They re essential to the safety and well-being of your customers. Homeowners rely on you as the heating professional who can help keep their boilers operating efficiently and safely. Replace old controls with genuine ITT McDonnell & Miller controls and replacement heads. You are assured of system compatibility, warranty coverage and product reliability. By following a recommended schedule for inspection and replacement of boiler controls, you can give your customers peace of mind and position yourself as the professional heating contractor they can trust. For more information on recommended replacement and inspection intervals, contact ITT McDonnell & Miller today. We ll show you how to safeguard your customers and your reputation. In 995, low water conditions and operator error/improper maintenance accounted for 8 percent of all boiler accidents, according to National Board Incident Reports N. Spaulding Avenue Chicago, Illinois 6068 tel: fax:

3 REPLACEMENT PARTS CATALOG ITT McDonnell & Miller the industry leader. Delivering reliable performance and safety in boiler and level control products for over 70 years. Whether it s ease of serviceability, continuous improvement, product enhancements or interchangeability, ITT McDonnell & Miller is continually doing more to give you the best performing residential, commercial and industrial liquid level and flow control products found anywhere. FLOW SWITCHES LIQUID LEVEL CONTROLS ITT MCDONNELL & MILLER IS AN INTERNATIONALLY CERTIFIED ISO 900 ORGANIZATION ITT McDonnell & Miller is the recipient of the highly coveted ISO 900 Certification. Recognized by more than 40 countries, these worldwide standards provide a uniform measure of quality procedures in manufacturing and service organizations. Participation in the rigid and demanding ISO 9000 Certification process is one of our most important activities. We want our customers and competitors both in the United States and abroad to know that we are dedicated to designing, producing and marketing the very highest quality products available anywhere. HOW TO USE THIS CATALOG This guide will assist you in your tour of the McDonnell & Miller Replacement Parts Catalog. The information contained in the catalog is organized into 4 key categories: Products Warranty & Return Policy Discontinued Parts List Maintenance & Replacement Interval Guidelines Easy to identify symbols and product icons will help you specify and select the replacement parts that meet your requirements. PRODUCTS the complete McDonnell & Miller product line, divided into 3 primary groups: Just check the CONTENTS pages for the associated product icons to quickly find the control you need replacement parts for. FLOW SWITCHES LIQUID LEVEL CONTROLS WARRANTY & RETURN POLICY gives you all the information regarding McDonnell & Miller warranty and return policies. INDEX helps you find the information by part number or catalog number. DISCONTINUED PARTS LIST easy locator to see if your part or product is no longer available. Discontinued Parts Cross Reference Part Number Model Number Description Replacement Part Number 005 M-SBV M switch for SBV No Replacement M-SBV 5M switch for SBV No Replacement M-HD-SBV 50M head for SBV No Replacement 3009 FS-4 Gasket, 6 pack C- Pin C-35 Lock nut F-6 Gasket, 6 pack MAINTENANCE & REPLACEMENT INTERVAL GUIDELINES the easy to read guides will help keep you on track with suggested product 369, 469 maintenance and replacement intervals. Recommended Replacement Intervals Recommended Replacement Recommended Interval Product Series Maintenance (Maximum) 50, 57, 58, 59, Blow down and test daily 5 years 50S, 57, 58S, 59S inspect annually. 69, 69, 69, Inspect and test annually. 0 years 67, 767 Blow down weekly. Inspect and 0 years 70, 70-B test annually. 6, 63, Blow down weekly. Inspect and 0 years 64, 764 test annually. Low Water Cut-Offs 4 down daily. Inspect Blow and 0 years test annually.

4 CONTENTS GENERAL INFORMATION LIQUID LEVEL CONTROLS FLOW SWITCHES Replacement Parts for: Boiler Controls Liquid Level Controls Flow Switches LOW WATER CUT-OFFS For Hot Water Boilers Replacement Probes For Steam Boilers BOILER CONTROL REPLACEMENT PARTS PS Series RB Series Series /70B 9 General Information Discontinued Parts List Part Number Cross Reference Index Warranty & Return Policy Maintenance & Replacement Interval Guidelines FOR SERIES PAGE LOW WATER CUT-OFFS FOR SERIES PAGE For Steam Boilers PS-800 Series Series 6 Combination Low Water Cut-Off/ Pump Controllers for Steam Boilers 4/4A 0 4S/4S-A 93/ / / S/57S 30 50E/57E 34

5 CONTENTS BOILER CONTROL REPLACEMENT PARTS (continued) WATER FEEDERS FOR SERIES PAGE WATER FEEDERS FOR SERIES PAGE Electric Uni-Match 35 WF 0-A 36 Mechanical 47/ / / S/5-S- 5 53/53-54 Make-Up 37 VALVES 5-A S S Test-N-Check TC-4 56 FLOW SWITCHES LIQUID LEVEL CONTROLS GENERAL INFORMATION 3

6 CONTENTS LIQUID LEVEL CONTROL PRODUCTS GENERAL INFORMATION LIQUID LEVEL CONTROLS FLOW SWITCHES CONDUCTANCE ACTUATED (PROBE TYPE) PNEUMATIC ACTUATED LIQUID FLOW General Purpose FS High Sensitivity FS 69 FOR SERIES PAGE FLOAT ACTUATED FOR SERIES PAGE LPC PCH 57 PCL 57 PFC 58 FLOW SWITCH PRODUCTS FOR SERIES PAGE FS4-3-T 66 FS5 67 FS8-W 68 FS-W 69 FS6 70 FS6-W 70 LIQUID FLOW AIR FLOW VFS 59 E W FOR SERIES PAGE Industrial FS7-4 7 FS7-4E 7 FS7-4W 7 AF 73 AFE- 74 AF 75 AF3 76 4

7 Replacement Probes PA-800 For Repl. Probe Part Weight Model Model No. Number Description lbs. (kg) PS-80-0 PA Probe 0.5 (.3) PS-85-0 PS-80-4 Dimensions, in. (mm) 3 /4 (0) NPT PS-85-4 RS--LP PS-85-M-0 PS-85-M-4.3 (33).56 (40).3 (54) PS-80-M-0 PS-80-M-4 PA-800-U For Repl. Probe Part Weight Model Model No. Number Description lbs. (kg) PS-80-U-0 PA-800-U 3544 Probe 0.5 (.3) PS-80-U-4 Dimensions, in. (mm) PS-85-M-U-0 3/4 (0) NPT PS-85-U-0 PS-80-M-U-4 PS-80-M-U-0.3 (33) 3.06 (78).56 (40) 5

8 Replacement Probes PA-800-RX For Repl. Probe Part Weight Model Model No. Number Description lbs. (kg) PS-80-RX-4 PA-800-RX Probe 0.5 (.3) PS-80-RX-4 Dimensions, in. (mm) PS-85-RX-0 / (5) NPT.3 (33) PA-RB-0 For Repl. Probe Part Weight Model Model No. Number Description lbs. (kg).56 (40).3 (54) PS-85-SP-0 PA-RB Probe 0.5 (.3) PS-85-SP-4 Dimensions, in. (mm) RB-0 3 /4 (0) NPT PS-85-M-SP-0 PS-85-M-SP-4.3 (33).56 (40).63 (4) PA-RB- For Repl. Probe Part Weight Model Model No. Number Description lbs. (kg) RB- PA-RB Probe 0.5 (.3) RS--LP-S Dimensions, in. (mm) 3 /4 (0) NPT.3 (33).56 (40).3 (4) 6

9 Low Water Cut-Offs Float Type For Steam Boilers Series 6 Low Water Cut-Offs Series 6 Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) 6-HD Head mechanism 3.5 (.6) 6 or Head mechanism.5 (0.7) Head mechanisms include a gasket and bolts. Part Catalog Weight Key Number Number Description lbs. (kg) Model 6-HD CO- Head Gasket 0. (0.5) Gasket 0. (0.5) SA67- Float & Bellows Assembly 0.3 (.4) Switch 0.5 (.3) M Switch w/manual Reset 0.5 (.3) MV Switch for Millivolt Service 0.5 (.3) Model

10 Low Water Cut-Offs Float Type For Hot Water Boilers Series 63 Low Water Cut-Offs Series 63 Replacement Head Mechanisms For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) B 63-BM 63-M 63-HD 4600 Head mechanism 7.0 (3.) w/ No. switch 63-M-HD HD w/manual reset 7.0 (3.) Model 63-HD Head mechanisms include a gasket and bolts. Model 63-M-HD (shown on page 9) Item Part Model Weight Number Number Number Description lbs. (kg) 0000 Switch.0 (0.5) 000 -M Switch w/manual reset.0 (0.5) SA63-5 Bellows assembly.5 (7.3) CO- Gasket 0. (.05) SA63-30 Float.0 (0.5) CO- Head gasket 0. (.05) CO-06 Cam 0. (.05) 8

11 Low Water Cut-Offs Float Type For Hot Water Boilers Series 63 (continued) Low Water Cut-Offs

12 Low Water Cut-Offs Float Type For Hot Water Boilers Series 64 Low Water Cut-Offs Series 64 Model 64-A Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) HD Head mechanism 4.0 (.8) 64-A Head mechanisms include a gasket and bolts. (shown on page ) Item Part Model Weight Number Number Number Description lbs. (kg) Model 64-HD SA64-30 Float assembly.0 (0.5) CO- Head gasket 0. (.05) SA64- Bellows assembly 0.3 (.4) (includes item ) Gasket 0. (.05) Switch 0.5 (.3) M No. w/manual reset 0.5 (.3) MV No. for Millivolt service 0.5 (.3) 8* MA-59 Quick hook-up fittings 4.5 (.0) (includes item 8, 9, 0) 9* SA59-4 Upper quick hook-up.7 (.77) 0* SA59-4 Lower quick hook-up.7 (.77) * SA59-7 Black Y assembly.3 (.0) *Available for 64-A models only 0

13 Low Water Cut-Offs Float Type For Hot Water Boilers Series 64 (continued) Low Water Cut-Offs

14 Low Water Cut-Offs Float Type For Hot Water Boilers Series 764 Low Water Cut-Offs Series 764 Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) HD Head mechanism 4.0 (.8) Head mechanisms include a gasket and bolts. Model 64-HD (shown on page 3) Item Part Model Weight Number Number Number Description lbs. (kg) SA64-30 Float assembly.0 (0.5) CO- Head gasket 0. (.05) SA64- Bellows assembly 0.3 (.4) (includes item ) Gasket 0. (.05) Switch 0.5 (.3) M No. w/manual reset 0.5 (.3) MV No. for Millivolt service 0.5 (.3)

15 Low Water Cut-Offs Float Type For Hot Water Boilers Series 764 (continued) Low Water Cut-Offs

16 Low Water Cut-Offs Float Type For Steam Boilers Series 67 Low Water Cut-Offs Series 67 Model 67-LQHU (without quick hook-up fittings) Replacement Head Mechanisms For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) LQHU Head mechanism.5 (0.7) 67-G 6667MV for Millivolt.5 (0.7) service Model 6667 (shown on page 5) Item Part Model Weight Number Number Number Description lbs. (kg) SA66-35 Upper tube assembly.0 (0.5) Model 6667MV MA559 Quick hook-up fittings.5 (.) Gasket 0. (.05) SA67- Float and bellows assembly.0 (0.5) Switch 0.5 (.3) M Switch w/manual reset 0.5 (.3) MV No. for Millivolt service 0.5 (.3) B Blow-down valve 0.5 (.3) Blow-down valve gasket 0. (.05) 4

17 Low Water Cut-Offs Float Type For Steam Boilers Series 67 (continued) Low Water Cut-Offs Model

18 Low Water Cut-Offs Float Type For Steam Boilers Series 767 Low Water Cut-Offs Series 767 Replacement Head Mechanisms For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) Head mechanism.5 (0.7) Model 6667 (shown on page 7) Item Part Model Weight Number Number Number Description lbs. (kg) Gasket 0. (.05) SA67- Float and bellows assembly.0 (0.5) Switch 0.5 (.3) M Switch w/manual reset 0.5 (.3) MV No. w/millivolt service 0.5 (.3) B Blow-down valve 0.5 (.3) Blow-down valve gasket 0. (.05) 6

19 Low Water Cut-Offs Float Type For Steam Boilers Series 767 (continued) Low Water Cut-Offs Model

20 Low Water Cut-Offs Float Type For Steam Boilers Series 69 Low Water Cut-Offs Replacement Head Mechanisms For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) J Series Head mechanism.5 (0.7) MV-P 6667-MV w/millivolt service.5 (0.7) Model 6667 Item Part Model Weight Number Number Number Description lbs. (kg) SA69-04 Shield assembly 0.5 (.3) Gasket 0. (.05) O-ring.0 (.004) O-ring.0 (.004) Gasket 0. (.05) Model 6667MV Switch 0.5 (.3) M Switch w/manual Reset 0.5 (.3) MV Switch for Millivolt Service 0.5 (.3) SA67- Float & Bellows Assembly 0. (.05)

21 Low Water Cut-Offs Float Type For Steam Boilers Series 70 Low Water Cut-Offs Replacement Head Mechanisms For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) Head mechanism.5 (0.7) Series 70 Model 70-B Item Part Model Weight Number Number Number Description lbs. (kg) B Blow-down valve.5 (0.7) Gasket 0. (.05) Model Gasket 0. (.05) Gasket 0. (.05) Switch 0.5 (.3) M Switch w/manual Reset 0.5 (.3) MV Switch for Millivolt Service 0.5 (.3) SA67- Float & Bellows Assembly 0. (.05) Head Mechanism.5 (0.7) MV Head Mechanism (Millivolt).5 (0.7)

22 Combination Low Water Cut-Off/Pump Controllers For Steam Boilers Series 4 Low Water Cut-Off/Pump Controllers Series 4 Model 4-A Replacement Head Mechanisms For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) 4 4-A 4-HD 9500 Head mechanism 7.5 (3.4) Model 4-HD (shown on page ) Item Part Model Weight Number Number Number Description lbs. (kg) SA50-5 Switch, wire 0.3 (.4) SA4-5 Switch, wire 0.3 (.4) CO- Head gasket 0. (.05) 4* MA-59 Quick hook-up fittings 6.0 (.7) (includes items 5, 6, 7) 5* SA59-4 Upper quick hook-up fittings.7 (.77) 6* SA59-4 Lower quick hook-up fittings.7 (.77) 7* SA59-7 Black Y assembly 3.0 (.4) * Available for 4-A models only. 0

23 Combination Low Water Cut-Off/Pump Controllers For Steam Boilers Series 4 (continued) Low Water Cut-Off/Pump Controllers

24 Combination Low Water Cut-Off/Pump Controllers For Steam Boilers Series 4S Low Water Cut-Off/Pump Controllers Replacement Head Mechanisms Series 4S For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) Model 4S-A 4S 4S-HD 950 Head mechanism 7.5 (3.4) Head mechanisms include a gasket and bolts. (shown on page 3) Item Part Model Weight Number Number Number Description lbs. (kg) Model 4S-HD CO- Head gasket 0. (.05) * MA-59 Quick hook-up fittings 6.0 (.7) (includes items 4, 5, 6) 3* SA59-4 Upper quick hook-up fittings.7 (.77) 4* SA59-4 Lower quick hook-up fittings.7 (.77) 5* SA59-7 Black Y assembly 3.0 (.4) * Available for 4S-A models only. Replacement Switch Information IMPORTANT: Snap switches must be replaced as an assembly. We recommend complete head replacement to eliminate the need for field replacement of the switch assembly. Series 4 & 4S Replacement Switch Assemblies are not interchangeable and must be selected and ordered for the specific control model(s) on which they will be installed. Replacement Switch Assemblies For Series 4S For Repl. Switch Part Weight Model Model No. Number Description lbs. (kg) 4S SWA-4S Snap-action 0.5 (.3) switch assembly Model SWA-4S

25 Combination Low Water Cut-Off/Pump Controllers For Steam Boilers Series 4S (continued) Low Water Cut-Off/Pump Controllers

26 Combination Low Water Cut-Off/Pump Controllers For Steam Boilers Series 93 & 93 Low Water Cut-Off/Pump Controllers Replacement Head Mechanisms For Repl. Head Weight Model Model No. Description lbs. (kg) 93, HD Head mechanism 6 (7.5) 93-7B-HD Head mechanism with 7B switch 6 (7.5) 93-M-HD Head mechanism, manual reset 6 (7.5) 93-7B-M-HD Head mechanism with 7B switch, 6 (7.5) manual reset (shown on page 5) Item Part Model Weight Number Number Number Description lbs. (kg) Series 93-HD HDLS Head w/o switch 5.0 (6.8) SA9-60 Float (includes item 3) 0.7 (.3) Gasket 0. (.05) Electric switch 3.5 (.6) M No. 5 w/manual reset 3.5 (.6) B Electric switch/ 4.0 (.8) proportioning control Series B-M No. 7B w/manual reset 4.0 (.8) #5 Switch SA9-30B Burner Switch 0. (.05) Contact Assembly (Red dot on terminal panel) (Includes A terminal panel) SA9-30P Pump Switch 0. (.05) Contact Assembly (Blue dot on terminal panel) (Includes A terminal panel) #7B Switch SA9-30B Burner Switch 0. (.05) Contact Assembly (Red dot on terminal panel) (Includes A terminal panel) B-R Resistor/Slide 0. (.05) Wire Assembly SA7-30 Terminal Panel 0.5 (.3) Series 93 4

27 Combination Low Water Cut-Off/ Pump Controllers For Steam Boilers Series 93 & 93 (continued) Low Water Cut-Off/Pump Controllers A 3 3 7B Switch A A 5 Switch 5

28 Combination Low Water Cut-Off/Pump Controllers For Steam Boilers Series 94 & 94 Low Water Cut-Off/Pump Controllers Replacement Head Mechanisms For Repl. Head Weight Model Model No. Description lbs. (kg) 94, HD Head mechanism (9.5) 94-M-HD Head mechanism, manual reset (9.5) 94-7B-HD Head mechanism with 7B switch (9.5) 94-7B-M-HD Head mechanism with 7B switch, (9.5) manual reset Series 94-HD (shown on page 7) Item Part Model Weight Number Number Number Description lbs. (kg) HDLS Head w/o switch 5.0 (6.8) SA9-60 Float (includes item 3) 0.7 (.3) Gasket 0. (.05) Electric switch 3.5 (.6) M No. 5 w/manual reset 3.5 (.6) Series B Electric switch/ 4.0 (.8) proportioning control B-M No. 7B w/manual reset 4.0 (.8) #5 Switch SA9-30B Burner Switch 0. (.05) Contact Assembly (Red dot on terminal panel) (Includes A terminal panel) SA9-30P Pump Switch 0. (.05) Contact Assembly (Blue dot on terminal panel) (Includes A terminal panel) #7B Switch SA9-30B Burner Switch 0. (.05) Contact Assembly (Red dot on terminal panel) (Includes A terminal panel) B-R Resistor/Slide 0. (.05) Wire Assembly SA7-30 Terminal Panel 0.5 (.3) Series 94 6

29 Combination Low Water Cut-Off/ Pump Controllers For Steam Boilers Series 94 & 94 (continued) Low Water Cut-Off/Pump Controllers A 3 3 7B Switch A A 5 Switch 7

30 Low Water Cut-Offs Float Type For Steam Boilers Series 50 & 57 Low Water Cut-Offs Consider our new Mercury Free Series 50S Replacement Head Mechanisms for an environmentally friendly alternative Series 50 Series 57 Replacement Head Mechanisms For Series 50 and 57 For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) HD Head mechanism w/ mercury switch 0.5 (4.8) or 50S-HD Head mechanism w/ snap switch.0 (5.4) or 50-M-HD HD w/manual reset.0 (5.4) or 50S-M-HD S-HD w/manual reset.0 (5.0) Model 57-RB-P 50-MD-HD HD w/maximum differential.0 (5.0) or 50S-MD-HD S-HD w/maximum differential.0 (5.0) 50 (MD) or 57 (MD) 50-M-MD-HD HD w/manual reset and.0 (5.0) 57-RB-P maximum differential or 50S-M-MD-HD S-HD w/manual reset and.0 (5.0) maximum differential 58-HD Head mechanism w/mercury switch.5 (5.7) or 58S-HD 7860 Head mechanism w/snap switch.5 (5.7) 58 or 58-M-HD HD w/manual reset.5 (5.7) or 58S-M-HD S-HD w/manual reset.5 (5.7) Series 50-HD 59-HD Head mechanism w/mercury switch.0 (5.4) 59 or 59S-HD 7890 Head mechanism w/snap switch.0 (5.4) Head mechanisms have a raised face flange and include a gasket and bolts. (S) in model number indicates snap switch. 8

31 Low Water Cut-Offs Float Type For Steam Boilers Series 50 & 57 (continued) Low Water Cut-Offs Item Part Model Weight Number Number Number Description lbs. (kg) Series 50 Head Gasket and Casting SA50-5 Mercury switch, wire 0.3 (.4) SA50-4 Mercury switch, 3 wire.4 (.06) SA50M-4 Mercury switch, 3 wire 0.3 (.4) (manual reset) SA50-06R Bellows assembly 0.4 (.8) SA50- Float & rod.0 (0.5) H Head gasket 0.5 (.3) (for raised face head flange, 8 holes) EA-57-S Short electrode for 57-RBP 0.5 (.3) EA-57-L Long electrode for 57-RBP 0.5 (.3) PCH-G-A- Probe level control.7 (.) SA50M-436 Cover for mercury switch,.435 (.9) manual reset only SA Cover for all other models.435 (.9) RAISED FLANGE GASKET CATALOGUE NO. 50-4H P.N This new gasket, specifically designed for the Raised Flange Heads, may be used. FLAT FLANGE GASKET CATALOGUE NO P.N RAISED FLANGE FLAT FLANGE This gasket must be used on the Flat Flange Heads Model PCH-G-A- Probe Type Low Water Cut-off 6 Series 50 & 57 Model 57-RBP Model PCH-G-A- 9

32 Low Water Cut-Off/Pump Controllers Series 50S & 57S Low Water Cut-Off/Pump Controllers with MERCURY FREE Snap-Action Switches Series 50S Series 57S Model 57S-RB-P Replacement Head Mechanisms For Series 50, 50S, 57, 57S For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) 50 50S-HD Head mechanism.0 (5.0) or 50S 50S-M-HD S-HD w/manual reset.0 (5.0) 57 57S Series 50S-HD 50 (MD) 50S (MD) 57 (MD) 50S-MD-HD S-HD w/maximum differential.0(5.0) 57S (MD) 50S-M-MD-HD S-HD w/manual reset and.0(5.0) 57-RB-P maximum differential 57S-RB-P 58 58S-HD 7860 Head mechanism.5 (5.7) or 58S 58S-M-HD S-HD w/manual reset.5 (5.7) 59 59S 59S-HD 7890 Head mechanism.0 (5.7) 30 Head mechanisms include a gasket and bolts. (S) in model number indicates snap switch.

33 Low Water Cut-Off/Pump Controllers Series 50S & 57S (continued) Low Water Cut-Off/Pump Controllers IMPORTANT: Snap switches must be replaced as an assembly. We recommend complete head replacement to eliminate the need for field adjustment of the switch assembly. Series 50S and 57S Replacement Switch Assemblies are not interchangeable with Series 50 and 57 mercury switch controls. Model SWA-50S Model SWA-50S-MD Replacement Switch Assemblies For Series 50S and 57S For Repl. Switch Part Weight Model Model No. Number Description lbs. (kg) 50S 50S-B 57S SWA-50S 3046 Snap-action 0.5 (.3) 57S-A switch assembly 57S-P 57S-R 57S-RL 50S-B-M 50S-BM-MD 50S-M-MD 50S-M 57S-A-M 57S-M 57S-M-MD 57S-M-RB-P-MD SWA-50S-M Snap-action 0.5 (.3) 57S-RB-M switch assembly 57S-RL-M w/manual reset 57S-R-M 50S-B-MD 50S-MD 57S-MD 57S-P-MD SWA-50S-MD Snap-action 0.5 (.3) 57S-R-MD switch assembly 57S-RB-MD for maximum 57S-RB-P-MD differential models 57S-RD-MD 57S-RLS-MD 58S SWA-58S Snap-action 0.5 (.3) switch assembly for Model 58S 58S-M SWA-58S-M SWA-58S 0.5 (.3) with manual reset Model SWA-50S-M Model SWA-58S Model SWA-58S-M Model SWA-59S 59S SWA-59S Snap-action 0.5 (.3) switch assembly Switch assemblies include a mounting bracket and color-coded terminal connection wires. 3

34 Low Water Cut-Off/ Pump Controllers Series 50S & 57S (continued) Low Water Cut-Off/Pump Controllers Item Part Model Weight Number Number Number Description lbs. (kg) Series 50 Head Gasket and Casting SA50-06R Bellows assembly 0.4 (.8) SA50- Float & rod.0 (0.5) H Head gasket for raised 0.5 (.3) face flange head, 8 holes EA-57-S Short electrode for 57S-RBP 0.5 (.3) EA-57-L Long electrode for 57S-RBP 0.5 (.3) PCH-G-A- Probe level control.7 (.) RAISED FLANGE GASKET CATALOGUE NO. 50-4H P.N RAISED FLANGE This new gasket, specifically designed for the Raised Flange Heads, may be used Cover.435 (.9) FLAT FLANGE GASKET CATALOGUE NO P.N FLAT FLANGE This gasket must be used on the Flat Flange Heads. 3

35 Low Water Cut-Off/ Pump Controllers Series 50S & 57S (continued) Low Water Cut-Off/Pump Controllers 7 Refer to page 3 for Switch Assemblies Series 50S Model 57S-RBP 6 Model PCH-G-A- Probe Type Low Water Cut-off Model PCH-G-A- 33

36 Low Water Cut-Offs Probe Type For Steam Boilers Series 50E & 57E Low Water Cut-Offs Replacement Head Mechanisms Series 50E For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) 50E E-HD Head, automatic reset 7.45 ( 3.48) 57E Series 57E Item Part Model Weight Number Number Number Description lbs. (kg) Series 57E-HD E-PF Flange/Probe assembly 5.38 (.5) E-CU Control unit, automatic reset.07 (.96) Series 50E and 57E 34

37 Water Feeders Electric Series WF Uni-Match Electric Water Feeders Item Part Model Weight Number Number Number Description lbs. (kg) Uni-Match STR-WF Strainer/orifice kit 0. (.05) 35

38 Water Feeders Electric Series 0-A Electric Water Feeders Item Part Model Weight Number Number Number Description lbs. (kg) Series 0-A CTRD-0 Cartridge & strainer kit 0.8 (.36) Tetraseal O-ring 0. (.05) V-48 Transformer (4V) 3.5 (.6) SA-0-38 Strainer (includes item ) 0.7 (.3) 3 4 Round Port Pilot Action Style Before August 995 Hex Port Cartridge Style After August

39 Water Feeders Make-Up Series Make-Up Water Feeders Item Part Model Weight Number Number Number Description lbs. (kg) Float.7 (.77) Gasket 0. (.05) Gasket 0. (.05) Series Gasket 0. (.05) SA-6 Valve assembly 3.0 (.4) (includes items, 3, 4 & 6) Gasket 0. (.05) SA5-9R Strainer assembly 3.0 (.4) SA-38R Strainer basket.0 (0.5) Tetraseal O-ring 0. (.05) Connector 0. (.05)

40 Water Feeders Make-Up Series 5-A Make-Up Water Feeders Series 5-A Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) 5-A 5A-HD 700 Head mechanism 0 (9.) Model 5-A-HD (shown on page 39) Item Part Model Weight Number Number Number Description lbs. (kg) F-6 Gasket 0. (.05) Float.5 (0.7) SA7T-75 Diaphragm seal assembly 0. (.05) (includes item ) SA5-5 Arm assembly 0. (.05) Gasket 0. (.05) Gasket 0. (.05) SA5-9R Strainer assembly 3.0 (.4) (includes item 7) Tetraseal O-ring 0. (.05) SA-38R Strainer basket.0 (0.5) SA5A-6 Valve assembly 3.0 (.4) SA5A-5 Stem & disc assembly 0.3 (.4) ` (includes item 7) T-9 Float Rod 0. (.05) 38

41 Water Feeders Make-Up Series 5-A (continued) Make-Up Water Feeders

42 Water Feeders Make-Up Series Make-Up Water Feeders Item Part Model Weight Number Number Number Description lbs. (kg) Float.7 (.77) F-6 Gasket 0. (.05) Gasket 0. (.05) Series Gasket 0. (.05) SA-6 Valve assembly 3.0 (.4) (includes,3,4,6) Gasket 0. (.05) SA5-9R Strainer assembly 3.0 (.4) SA-38R Strainer basket.0 (0.5) Tetraseal O-ring 0. (.05) Connector 0. (.05)

43 Water Feeders Make-Up Series 55-S Make-Up Water Feeders Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) 55-S 55S-HD Head mechanism 5.7 (.7) Item Part Model Weight Number Number Number Description lbs. (kg) Series 55-S * FLT-5 Float (includes item ).5 (.) F-6 Gasket 0. (.05) 3* BA-55 Bellows bracket assembly.5 (0.7) Gasket 0. (.05) 5** SA55S-0-0 Valve & strainer kit 4.0 (.8) Tetraseal o-ring 0. (.05) Series 55-S-HD SA0-38 Strainer basket 0.7 (.3) (includes item 6 and bolts) CTRD-5 Cartridge kit 0.8 (.36) Bellows Bracket Assembly for Series 5, 5S, 53, 355, and 55S 4 4 April 999 or Before 3 Round Boss Pilot Action Style Pre August 995 Hex Boss Cartridge Style After August 995 ** Units manufactured prior to August 995 have a round port pilot valve and a strainer assembly. These valve and strainer assemblies can be replaced with the current hex port cartridge valve and strainer assembly May 999 and After *One time float and bellows replacement is required when replacing bellows or float assemblies with date codes before May

44 Water Feeders Make-Up Series 847 Make-Up Water Feeders Item Part Model Weight Number Number Number Description lbs. (kg) A-30 Float (includes item ).0 (0.9) Gasket 0. (.05) SA847-4 Bellows bracket assembly.5 (0.7) (includes item and 4) Series Gasket 0. (.05) 5* SA Valve & strainer kit 3.0 (.4) Tetraseal O-ring 0. (.05) SA0-38 Strainer basket 0.7 (.3) (includes item 6 and bolts) CTRD-0 Cartridge & strainer kit 0.8 (.36) Switch.0 (0.5) Round Boss Pilot Action Style Pre August 995 Hex Boss Cartridge Style After August 995 * Units manufactured prior to August 995 have a round port pilot valve and a strainer assembly. These valve and strainer assemblies can be replaced with the current hex port cartridge valve and strainer assembly

45 Water Feeders Make-Up Series 85 Make-Up Water Feeders Item Part Model Weight Number Number Number Description lbs. (kg) A-30 Float (includes item ).0 (0.9) Gasket 0. (.05) SA85-4 Bellows bracket assembly.5 (0.7) Series Gasket 0. (.05) 5* SA5-0-0 Valve & strainer kit 3.0 (.4) Tetraseal O-ring 0. (.05) SA0-38 Strainer basket 0.7 (.3) (includes item 6 and bolts) CTRD-5 Cartridge & strainer kit 0.8 (.36) Float rod 0.3 (.4) Switch.0 (.05) Round Boss Pilot Action Style Pre August 995 Hex Boss Cartridge Style After August * Units manufactured prior to August 995 have a round port pilot valve and a strainer assembly. These valve and strainer assemblies can be replaced with the current hex port cartridge valve and strainer assembly. 43

46 Water Feeders Make-Up Series 85-S Make-Up Water Feeders Item Part Model Weight Number Number Number Description lbs. (kg) A-30 Float (includes item ).0 (.9) Gasket 0. (.05) SA85-4 Bellows bracket assembly.5 (.7) (includes item 4) Series 85-S Gasket 0. (.05) SA5S-6 Valve assembly 3.0 (.4) S-4 Valve seat 0. (.05) Gasket 0. (.05) Tetraseal O-ring 0. (.05) SA37-38 Strainer basket 0.7 (.3) (includes item 8 and bolts) SA5-9 Strainer assembly 3.0 (.4) S-05 Float rod 0.3 (.4) 0000 Switch.0 (0.5)

47 Water Feeders Make-Up Series 355 Make-Up Water Feeders Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) HD Head mechanism 5.7 (.7) Item Part Model Weight Number Number Number Description lbs. (kg) Series 355 * FLT-5 Float (includes item ).5 (.) F-6 Gasket 0. (.05) 3* BA-355 Bellows assembly.5 (.7) (includes item 4) Gasket 0. (.05) Gasket 0. (.05) Model 355-HD Gasket 0. (.05) Gasket 0. (.05) SA355-6 Valve assembly 3.0 (.4) 5 4 Bellows Bracket Assembly for Series 5, 5S, 53, 355, and 55S April 999 or Before May 999 and After 7 *One time float and bellows replacement is required when replacing bellows or float assemblies with date codes before May

48 Combination Mechanical Water Feeder/ Low Water Cut-Offs Series 47/47- Mechanical Water Feeder/Low Water Cut-Offs (shown on page 47) Item Part Model Weight Number Number Number Description lbs. (kg) CTRD-0 Cartridge and strainer kit.35 (.6) Series 47 * SA Valve, cartridge & strainer 3.0 (.4) assembly kit Tetraseal o-ring 0. (.05) SA0-38 Strainer for hex port valves 0. (.09) (includes item 3 and bolts) SA47-4 Bellows and bracket assembly.5 (0.7) (includes item 5) Gasket 0. (.05) CO-06 Cam assembly 0. (.05) Switch.0 (0.5) M Switch with manual reset.0 (0.5) MA-59 Quick hook-up fittings 4.5 (.0) (includes item,, 3) SA59-7 Black Y assembly.3 (.0) SA59-4 Upper quick hook-up fittings.7 (.77) SA59-4 Lower quick hook-up fittings.7 (.77) SA37-30 Float assembly.0 (0.9) Gasket 0. (.05) B Blow-down valve.5 (0.7) (includes item 7) Blow-down valve gasket.0 (0.5) Series 47- Round Port Pilot Action Style Before August 995 Hex Port Cartridge Style After August 995 * Units manufactured prior to August 995 have a round port pilot valve and a strainer assembly. These valve and strainer assemblies can be replaced with the current hex port cartridge valve and strainer assembly. 46

49 Combination Mechanical Water Feeder/ Low Water Cut-Offs Series 47/47- (continued) Mechanical Water Feeder/Low Water Cut-Offs

50 Combination Mechanical Water Feeder/ Low Water Cut-Offs Series 47/47- Mechanical Water Feeder/Low Water Cut-Offs (shown on page 49) Item Part Model Weight Number Number Number Description lbs. (kg) CTRD-0 Cartridge & strainer kit.35 (.6) * SA Valve, cartridge & strainer 3.0 (.4) assembly kit Tetraseal o-ring 0. (.05) SA0-38 Strainer for hex port valves 0. (.09) (includes item 3 and bolts) SA47-04 Bellows & bracket assembly.5 (0.7) (includes item ) Gasket 0. (.05) CO-06 Cam assembly 0. (.05) Switch.0 (0.5) M Switch w/manual reset.0 (0.5) SA37-30 Float assembly.0 (0.9) (includes item ) Gasket 0. (.05) Series 47 Series 47- Round Boss Pilot Action Style Pre August 995 Hex Boss Cartridge Style After August 995 * Units manufactured prior to August 995 have a round port pilot valve and a strainer assembly. These valve and strainer assemblies can be replaced with the current hex port cartridge valve and strainer assembly. 48

51 Combination Mechanical Water Feeder/ Low Water Cut-Offs Series 47/47- (continued) Mechanical Water Feeder/Low Water Cut-Offs

52 Combination Mechanical Water Feeder/ Low Water Cut-Offs Series 5/5- Water Feeder/Low Water Cut-Offs Series 5 Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) 5--HD 3500 Head mechanism w/ No. switch 8.3 (8.3) 5- or 5-M-HD HD w/manual reset 6.0 (.8) Series 5- (shown on page 5) Item Part Model 0000 Low water cut-off switch.0 (0.5) Model 5--HD 000 -M No. w/manual reset.0 (0.5) 3* FLT-5 Float.5 (.) F-6 Gasket 0. (.05) Gasket 0. (.05) CO-06 Cam assembly 0. (.05) 7* 3048 BA-5 Bellows bracket assembly.5 (0.7) (includes item 4) 8** SA5-0-0 Valve & strainer kit 3.0 (.4) CTRD-5 Cartridge & strainer kit 0.8 (.36) Tetraseal O-ring 0. (.05) SA0-38 Strainer basket 0.7 (.3) (includes item 0 and bolts) 50

53 Combination Mechanical Water Feeder/ Low Water Cut-Offs Series 5/5- (continued) Water Feeder/Low Water Cut-Offs Round Boss Pilot Action Style Pre August 995 Hex Boss Cartridge Style After August ** Units manufactured prior to August 995 have a round port pilot valve and a strainer assembly. These valve and strainer assemblies can be replaced with the current hex port cartridge valve and strainer assembly. Bellows Bracket Assembly for Series 5, 5S, 53, 355, and 55S April 999 or Before May 999 and After *One time float and bellows replacement is required when replacing bellows or float assemblies with date codes before May

54 Combination Mechanical Water Feeder/ Low Water Cut-Offs Series 5-S/5-S- Water Feeder/Low Water Cut-Offs Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) 5-S--HD 3600 Head mechanism w/ No. switch 0.5 (9.3) 5-S or 5-S-M-HD S--HD w/manual reset.7 (9.8) Series 5-S (shown on page 53) Item Part Model Weight Number Number Number Description lbs. (kg) 0000 Low water cut-off switch.0 (0.5) 000 -M No. w/manual reset.0 (0.5) 3* FLT-5 Float.5 (.) F-6 Gasket 0. (.05) Gasket 0. (.05) CO-06 Cam assembly 0. (.05) 7* 3048 BA-5 Bellows bracket assembly.0. (0.7) (includes item 4) SA5S-6 Valve assembly 3.0 (.4) S-4 Valve seat 0.8 (.36) SA5-9 Strainer assembly 0. (.05) Gasket 0. (.05) Tetraseal O-ring 0. (.05) SA37-38 Strainer basket 0.7 (.3) (includes item ) Series 5-S- Model 5-S--HD Model 5-S-M-HD 5

55 Combination Mechanical Water Feeder/ Low Water Cut-Offs Series 5-S/5-S- (continued) Water Feeder/Low Water Cut-Offs Bellows Bracket Assembly for Series 5, 5S, 53, 355, and 55S 0 April 999 or Before May 999 and After 3 *One time float and bellows replacement is required when replacing bellows or float assemblies with date codes before May

56 Combination Mechanical Water Feeder/ Low Water Cut-Offs Series 53/53- Water Feeder/Low Water Cut-Offs Series 53 Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) 53--HD Head mechanism w/ No. switch 0.5 (9.3) 53 or 53-M-HD HD w/manual reset 0.5 (9.3) Series 53- (shown on page 55) Item Part Model Weight Number Number Number Description lbs. (kg) 0000 Low water cut-off switch.0 (0.5) Model 53--HD 000 -M No. w/manual reset.0 (0.5) F-6 Gasket 0. (.05) 4* 3048 FLT-53 Float 4.0 (.8) CO-06 Cam assembly 0. (.05) Gasket 0. (.05) 7* BA-53 Bellows bracket assembly.5 (0.7) (includes item 3) SA53-6 Valve assembly 3.0 (.4) Model 53-M-HD Gasket 0. (.05) Tetraseal O-ring 0. (.05) SA37-38 Strainer basket 0.7 (.3) 54

57 Combination Mechanical Water Feeder/ Low Water Cut-Offs Series 53/53- (continued) Water Feeder/Low Water Cut-Offs Bellows Bracket Assembly for Series 5, 5S, 53, 355, and 55S 0 April 999 or Before May 999 and After *One time float and bellows replacement is required when replacing bellows or float assemblies with date codes before May

58 Valves Series TC-4 Test-N-Check Valves Item Part Model Weight Number Number Number Description lbs. (kg) Series TC-4 Upper Valve TC-V Vacuum breaker w/gasket 0.3 (.4) TC-U Upper valve (includes item ).7 (.) TC-L Lower valve.7 (.) Series TC-4 Lower Valve 3 56

59 BOILER LIQUID LEVEL CONTROL CONTROL REPLACEMENT REPLACEMENT PARTS PARTS Probe Type Remote Sensors for Remote Sensors Series PCH & PCL Control Unit For Item Part Model Weight Model Number Number Number Description lbs. (kg) Series LPC-000 Control Unit RS--BR GSKT-RS- Cover gasket 0.3 (.4) EA-RS Electrode 0.5 (.3) RS--LP PA-800 Probe 0.5 (.3) RS--BR- RS 3 RS 4 RS GSKT-RS- Cover gasket 0.3 (.4) EA-RS Electrode 0.5 (.3) Series LPC-000-W Control Unit 4 Remote Sensor Model RS--BR- LIQUID LEVEL CONTROLS 5 Remote Sensor Model RS--LP 3 Series RS Model RS--LP Model RS--BR- Remote Sensor Series RS 57

60 LIQUID LEVEL CONTROL REPLACEMENT PARTS Pneumatic Actuated Series PFC Liquid Level Controls Item Part Model Weight Number Number Number Description lbs. (kg) 3047 SWA-PFC-D Valve assembly-da.0 (0.9) 3047 SWA-PFC-R Valve assembly-ra.0 (0.9) G-PFC-S Supply gauge 0.3 (.4) Series PFC G-PFC-O Output gauge 0.3 (.4) FLT-PFC Float (includes item 6) 0.5 (.3) GSKT-PFC Gasket 0. (.09) LIQUID LEVEL CONTROLS

61 BOILER LIQUID LEVEL CONTROL CONTROL REPLACEMENT PARTS PARTS Float Actuated Series VFS Liquid Level Controls Item Part Model Weight Number Number Number Description lbs. (kg) GSKT-VFS- Cover gasket for vapor 0. (.09) proof models ( V designated) SWA-VFS SPDT switch module 0.5 (.3) Series VFS FLT-PFC Float 0.5 (.3) GSKT-PFC Gasket 0. (.09) LIQUID LEVEL CONTROLS

62 LIQUID LEVEL CONTROL REPLACEMENT PARTS Float Actuated For Fuel Oil Series E-8 Liquid Level Controls Series E-8 Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) E-8 80-HD 5800 Head mechanism.5 (0.7) Model 80-HD LIQUID LEVEL CONTROLS Item Part Model Weight Number Number Number Description lbs. (kg) O-ring 0. (.05) O-ring 0. (.05) 60

63 LIQUID LEVEL CONTROL REPLACEMENT PARTS Float Actuated Series 7-W Liquid Level Controls Item Part Model Weight Number Number Number Description lbs. (kg) Series 7-W Float.5 (0.7) Gasket 0. (.05) SA7W-6 Valve assembly 3.5 (.6) (includes item ) LIQUID LEVEL CONTROLS 3 6

64 LIQUID LEVEL CONTROL REPLACEMENT PARTS Float Actuated For Liquid Series 65 Liquid Level Controls Replacement Head Mechanisms For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) 65-HD Head mechanism 9.3 (8.8) 65 or 65-R-HD HD w/reverse action 9.3 (8.8) Series 65 Item Part Model Weight Number Number Number Description lbs. (kg) CO- Gasket 0. (.05) SA60-30 Float (includes item ).0 (0.5) SA65-5 Direct action switch 0.3 (.4) Model 65-HD SA65-5 Reverse action switch 0.3 (.4) LIQUID LEVEL CONTROLS Model 65-R-HD 3 4 6

65 LIQUID LEVEL CONTROL REPLACEMENT PARTS Float Actuated For Fuel Oil Series 80 Liquid Level Controls Series 80 Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) HD 5800 Head mechanism.5 (0.7) Model 80-HD Item Part Model Weight Number Number Number Description lbs. (kg) Gasket 0. (.05) LIQUID LEVEL CONTROLS 63

66 LIQUID LEVEL CONTROL REPLACEMENT PARTS Float Actuated For Liquid Series 65 Liquid Level Controls Replacement Head Mechanisms For Repl. Head Part Weight Model Model No. Number Description lbs. (kg) 65-HD 4700 Head mechanism 9.3 (8.8) 65 or 65-R-HD HD w/reverse action 9.3 (8.8) Series 65 Item Part Model Weight Number Number Number Description lbs. (kg) CO- Gasket 0. (.05) SA60-30 Float (includes item ).0 (0.5) SA65-5 Direct action switch 0.3 (.4) Model 65-HD SA65-5 Reverse action switch 0.3 (.4) G-39 Gasket 0. (.05) LIQUID LEVEL CONTROLS 5 Model 65-R-HD

67 FLOW SWITCH REPLACEMENT PARTS Flow Switches Liquid Series FS4-3 General Purpose Liquid Flow Switches For Item Part Model Weight Model Number Number Number Description lbs. (kg) All models FS4-5 Monel paddle kit 0. (.05) (except those below) 3045 FS4-5SS Stainless steel paddle kit 0. (.05) Series FS FS4-33 SPDT switch 0.3 (.4) FS4-3RP FS4-5RP Monel paddle kit 0.08 (.36) FS4-3F FS4-5F Paddle kit 0. (.05) FS4-3D FS4-3D-7 SPDT switch 0.3 (.4) FS-7 SPDT switch (next to 0.3 (.4) adjustment screw) FLOW SWITCHES Note: Paddle kits include screws and washers. " " 3" 6" (5mm) (5mm) (76mm) 6 NORM NORM OPEN CLOSED NORM CLOSED COMMON OPEN COMMON NORM 7 (5mm) " 6" 3 (5mm) 4 FLOW (5mm) " " 5 (5mm) (5mm) Series FS4-3 Series FS4-3D Paddle Kits 65

68 FLOW SWITCH REPLACEMENT PARTS Flow Switches Liquid Series FS4-3T General Purpose Liquid Flow Switches Item Part Model Weight Number Number Number Description lbs. (kg) FS4-33 SPDT switch 0.3 (.4) FS4-3T-5 Paddle kit 0. (.05) (includes O-ring) Note: Paddle kits include screws and washers. Series FS4-3T FLOW SWITCHES FLOW " " /" (5mm) For Model FS4-3T FS4-3T FS4-3T3 (5mm) For Model FS4-3T3 (5mm) For Model FS4-3T 66

69 FLOW BOILERSWITCH CONTROL REPLACEMENT PARTS PARTS Flow Switches Liquid Series FS5 General Purpose Liquid Flow Switches Item Part Model Weight Number Number Number Description lbs. (kg) FS-7 Switch 0.3 (.4) Series FS5 FLOW SWITCHES Series FS5 67

70 FLOW SWITCH REPLACEMENT PARTS Series FS8-W General Purpose Liquid Flow Switches Item Part Model Weight Number Number Number Description lbs. (kg) GSKT-FS8W O-ring 0. (.05) FS-7 Switch 0.3 (.4) FS4-5 Monel Paddle kit 0. (.05) Series FS8-W FS4-5SS Stainless steel paddle kit 0. (.05) FS4-5RP Stainless steel paddle kit.08 (0.4) FLOW SWITCHES Note: Paddle kits include screws and washers. " " 3" 6" (5mm) (5mm) (76mm) 3 (5mm) " 6" (5mm) 4 (5mm) Series FS8-W Paddle Kits 68

71 FLOW BOILERSWITCH CONTROL REPLACEMENT PARTS PARTS Flow Switches Liquid Series FS & FS-W High Sensitivity Liquid Flow Switches Item Part Model Weight Number Number Number Description lbs. (kg) 3003 GSKT-FS/6W O-ring 0.3 (.4) FS-7 Switch 0. (.05) Series FS FLOW SWITCHES Series FS-W Series FS Series FS-W 69

72 FLOW SWITCH REPLACEMENT PARTS Flow Switches Liquid Series FS6 & FS6-W High Sensitivity Liquid Flow Switches Item Part Model Weight Number Number Number Description lbs. (kg) 3003 GSKT-FS/6W O-ring 0. (.05) FS-7 Switch 0.3 (.4) Series FS6 FLOW SWITCHES Series FS6-W Series FS6 Series FS6-W 70

73 FLOW BOILERSWITCH CONTROL REPLACEMENT PARTS PARTS Flow Switches Liquid Series FS7-4, FS7-4L & FS7-4S Industrial Liquid Flow Switches For Item Part Model Weight Series Number Number Number Description lbs. (kg) FS7-4 FS7-4S FS7-3 SPDT switch 0.3 (.4) FS7-4L Series FS7-4 FS FS7S-4R-4 Paddle arm 0.5 (.3) FS7-4S FS FS7-8 Bronze paddle kit 0. (.05) FS7-4S FS7-8S Stainless steel paddle kit 0. (.05) FLOW SWITCHES FS7-4L 5* FS7-8L Bronze paddle kit 0. (.05) FS7-4L 6* FS7-VL-4R-4 Paddle arm 0.5 (.3) Series FS7-4L Note: Paddle kits include screws and washers. * Available on L models only " 6" (5mm) 6 Series FS7-4, FS7-4L & FS7-4S (5mm) Series FS7-4 & FS7-4S Paddle Kit " (305mm) Series FS7-4L Paddle Kit 7

74 FLOW SWITCH REPLACEMENT PARTS Flow Switches Liquid Series FS7-4E & FS7-4W Industrial Liquid Flow Switches For Item Part Model Weight Series Number Number Number Description lbs. (kg) All models FS7-4E FS7-4W FS7-3 SPDT switch 0.3 (.4) FS7S-4R-4 Paddle arm 0.4 (.8) FS7-8 Bronze paddle kit 0. (.05) Series FS7-4E & FS7-4W FLOW SWITCHES FS7-4SE FS7-4SW FS7-4W FS7-4SW FS7-8S Stainless steel paddle kit 0. (.05) FS7-W-43 Gasket 0. (.05) Note: Paddle kits include screws and washers " 6" (5mm) (5mm) Series FS7-4E Series FS7-4W Paddle Kits 7

75 FLOW SWITCH REPLACEMENT PARTS Flow Switches Air Series AF Air Flow Switches Item Part Model Weight Number Number Number Description lbs. (kg) FS7-3 SPDT switch 0.3 (.4) 3000 AF- Gasket 0. (.05) AF- Paddle kit for model AF & AF-J 0. (.05) (includes item ) Series AF AF-S- Paddle kit for model AF-S 0. (.05) (includes item ) Note: Paddle kits include screws and washers. FLOW SWITCHES

76 FLOW SWITCH REPLACEMENT PARTS Flow Switches Air Series AFE- Air Flow Switches Item Part Model Weight Number Number Number Description lbs. (kg) FS-7 SPDT switch 0.3 (.4) AFE-- Paddle kit 0. (.05) (includes item 3) Series AFE AFE-- Gasket 0. (.05) FLOW SWITCHES Note: Paddle kits include screws and washers. 3 74

77 FLOW SWITCH REPLACEMENT PARTS Flow Switches Air Series AF Air Flow Switches Item Part Model Weight Number Number Number Description lbs. (kg) FS7-3 SPDT switch 0.3 (.4) 3000 AF- Gasket 0. (.05) AF- Paddle kit 0. (.05) (includes item ) Series AF Note: Paddle kits include screws and washers. FLOW SWITCHES 3 75

78 FLOW SWITCH REPLACEMENT PARTS Flow Switches Air Series AF3 Air Flow Switches Item Part Model Weight Number Number Number Description lbs. (kg) FS7-3 SPDT switch 0.3 (.4) 3000 AF- Gasket 0. (.05) AF3- Paddle kit 0. (.05) (includes item ) Series AF3 Note: Paddle kits include screws and washers. FLOW SWITCHES 3 76

79 NOTES GENERAL INFORMATION 77

80 DISCONTINUED PARTS CROSS REFERENCE This list enables you to quickly determine which parts are no longer available. Suitable replacement parts/kits are listed. DISCONTINUED PARTS Part Number Catalog Number Description Replacement/Where to Find Switch Level 5 Switch M Switch Level Man. Reset 5M Switch A Make-Up Water Feeder Series 8 or 8LF Make-Up Water Feeder Series 8 or 8LF Probe Level Control Series PS C Probe Level Control Series PS M Probe Level Control Series PS85-M Probe Level Control Series RB M Probe Level Control Series PS85-M M Probe Level Control Series PS85-M PS-80-4 Probe Control LWCO Series PS PS-80-U-4 Probe Control LWCO Series PS-80-U PS-80-M-4 Probe Control LWCO Series PS-80-M PS-85-4 Probe Control LWCO Series PS PS-85-M-4 Probe Control LWCO Series PS-85-M PS-80-RX-4 Probe Control LWCO Series PS-80-RX High Pressure Level Control Series HD Head Mechanism 93-HD HD Head Mechanism 94-HDLS and 5 Switch 8000 VFC-M-G Float Level Control Series VFS 800 VFC-A-G Float Level Control Series VFS 800 VFC-M-V Float Level Control Series VFS 8030 VFC-A-V Float Level Control Series VFS 8040 VFC-M-G Float Level Control Series VFS 8050 VFC-A-G Float Level Control Series VFS 8060 VFC-M-V Float Level Control Series VFS 8070 VFC-A-V Float Level Control Series VFS 8080 VFC-3M-G Float Level Control Series VFS 8090 VFC-3A-G Float Level Control Series VFS 8000 VFC-3M-V Float Level Control Series VFS 800 VFC-3A-V Float Level Control Series VFS 800 VFS-M-G Float Level Control Series VFS-V 8030 VFS-A-G Float Level Control Series VFS-V 8060 VFS-M-G Float Level Control Series VFS-V 8070 VFS-A-G Float Level Control Series VFS-V VFS-3M-G Float Level Control Series VFS-V 8030 VFS-3A-G Float Level Control Series VFS-V 8080 PDC--GS Pneumatic Displr Control Series PFC or LPC PDC--GR Pneumatic Displr Control Series PFC or LPC C-35 Lock Nut CO CO-8 Adjusting Screw CO FS4-5 Replacement Paddle in. FS4-5 Paddle Kit FS4-6 Replacement Paddle in. FS4-5 Paddle Kit FS4-7 Replacement Paddle 3 in. FS4-5 Paddle Kit FS4-5 Replacement Paddle FS4-3T-5 Paddle Kit FS4-37 Replacement Paddle 6 IN FS4-5 Paddle Kit FS4T-40 Replacement Paddle FS4-3T-5 Paddle Kit FS4T-4 Replacement Seal FS4-3T-5 Paddle Kit FS7-8 Replacement Paddle FS7-8 Paddle Kit FS7-7 Replacement Paddle FS7-8S Paddle Kit FS7S-7 Replacement Spring Series FS, FS6 & FS XF-36 Screw Replacement 3/8-6 x Hex Steel Cap Screw Replacement Washer Series Replacement Washer Series Replacement Nut Series Replacement Washer Series SA4-5 Bellows Assembly Series 4 or 4-HD Isolation Gasket SA-50-06R Brass Nipple / x 3-/ MA Brass Nipple /x-/4 MA Screw 4/Box 5/6-8 x 3/4 Fillister Head Machine Screw Valve Bracket Replacement Bellows Pin CO MA-59 Union Tail SA MA-59 Nipple SA Valve Seat SA-6 or SA MA-59 Washer SA MA-59 Tube SA MA-59 Packing SA / Brass Tee MA559 78

Boiler Control Replacement Parts

Boiler Control Replacement Parts Low Water Cut-Offs Float Type Series 6 Low Water Cut-Offs Series 6 Replacement Head Mechanisms For Repl. Head Part Weight Series Model No. Number Description lbs. (kg) 6-HD 40300 Head mechanism 3.5 (.6)

More information

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)

CFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1 NPT (Typ. Both Ends 2 Places) MODEL Float Control For Closed Tanks Accurate Liquid Level Control Fully Hydraulic Operation Simple Design, Easy Maintenance No Lubrication Necessary No Gears, No Mechanical Linkage Between Valve and Control

More information

V43 Pressure Actuated Water Regulating Valve

V43 Pressure Actuated Water Regulating Valve FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled

More information

Series Way Ball Valve Threaded. SERIES 38 3-Way. Easy to Automate! See automated data sheets for pre-sized assemblies 38-TH-0025-XXX-T

Series Way Ball Valve Threaded. SERIES 38 3-Way. Easy to Automate! See automated data sheets for pre-sized assemblies 38-TH-0025-XXX-T This investment cast 3-way valve can be an economical option for flow patterns that normally require multiple 2-way valves. Available in L or T port configurations, this valve is excellent for diverting

More information

Rate of Flow Valve Series 120

Rate of Flow Valve Series 120 SPECIFICATIONS Rate of Flow Valve Series DIMENSIONS The OCV Series 120 Rate of Flow control valve is designed to control or limit flow to a predetermined rate, regardless offl uctuations in downstream

More information

Float Operated Level Controllers

Float Operated Level Controllers CONTENTS Float Operated Level Controllers IM0015 Nov. 2014 PAGE Introduction 1 Scope 1 Description 1 Specification 1 Control Installation 2 INTRODUCTION Side Mount Back Mount Prior to installing, the instructions

More information

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT

PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT PILOT OPERATED RELIEF VALVE SAFETY PRODUCTS THAT PROTECT EQUIPMENT, LIVES & THE ENVIRONMENT Model Number Model Description Page # Pilot operated Relief Valves Pilot Operated Relief Valves 3-27 Operation

More information

Spare parts list ( ) Spare parts list HDS 990

Spare parts list ( ) Spare parts list HDS 990 Spare parts list (5.952-855.0) Spare parts list HDS 990 13.10.2014 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list HDS 990 (5.952-855.0)... 6 10 Individual parts... 7 49 Spare

More information

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK

V5197A. Firing Rate Gas Valve APPLICATION FEATURES PRODUCT HANDBOOK V5197A Firing Rate Gas Valve PRODUCT HANDBOOK APPLICATION The V5197A are firing rate valves used to provide variable flow control of air, natural gas, liquefied petroleum (LP), and manufactured gases.

More information

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08

Parts Manual STRIKER Striker 2840 Parts List - PN Printed in USA 03/18/08 Parts Manual STRIKER 2840 Striker 2840 Parts List - PN 238155 - Printed in USA 03/18/08 Standard Parts Recommended General Wear Parts Ref No Part Description Qty Part No 1 Squeegee Hose Assembly

More information

Liquid Level Controls

Liquid Level Controls Series RS High Pressure Sensors & Probes For onductance ctuated ontrols Series RS Sensors Series-RS-X-BR-: NM 4X nclosure For sophisticated multi-level control in tanks, boilers and hydronic systems Remote

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

Series 8R HIGH PERFORMANCE

Series 8R HIGH PERFORMANCE Triac 8R Series s are the finest quality 3-piece valves on the market. The high quality investment castings feature a fully machined bore. The superior live-loaded packing system is accomplished with Belleville

More information

K Page 1 of 48 Air Intake - Pg. 17

K Page 1 of 48 Air Intake - Pg. 17 K532-53168 Page 1 of 48 Air Intake - Pg. 17 Ref # Part Number Qty Description 24 25 041 06-S 1 Gasket, elbow 25 48 054 09 1 Elbow, air cleaner Discontinued not available at Kohler Co. 35 277116-S 1 Brace,

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections Features General application The RP03 provides protection from both backsiphonage and backpressure

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.

More information

FILTER BYPASS CONTROL

FILTER BYPASS CONTROL Differential Control Valve Series 110 The Series 110 Differential Control Valve is designed to accurately control the pressure difference between any two points. In some systems this means the valve remains

More information

3" 24" 80A 600A DN80 DN600 Body size The largest size manufactured : 60" (1500A) Disc form Damper type Trim materials Trim treatment

3 24 80A 600A DN80 DN600 Body size The largest size manufactured : 60 (1500A) Disc form Damper type Trim materials Trim treatment STANDARD SPECIFICATION SS-CE-600B-A JUL. 2004 600B Disc Damper Type Butterfly Valve GENERAL 600B STANDARD SPECIFICATIONS BODY Series 600B This series 600B is a wafer type butterfly valve, designed to be

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.

MUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5. Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read

More information

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03 Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure

More information

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual

Welker Sampler. Model GSS-1. Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Sampler Model GSS-1 The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

LGB Series 1 & 2 Section And Base Assembly

LGB Series 1 & 2 Section And Base Assembly LGB Series 1 & 2 Section And Base Assembly Current Service Parts 263 LGB Series 1 & 2 Section And Base Assembly Fig. Part Size Description 383-300-405 Section replacement kit, Includes seals, rope and

More information

Water Safety Shut-off Valve HON 790

Water Safety Shut-off Valve HON 790 Water Safety Shut-off Valve HON 790 790.20 OPERATING AND MAINTENANCE INSTRUCTIONS/ SPARE PARTS EDITION 01/2017 Serving the Gas Industry Worldwide Contents Page 1. General information 3 1.1 Safety information

More information

Operation Manual. Diaphragm Sensed Gas Pressure Regulators

Operation Manual. Diaphragm Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Diaphragm Sensed Gas (AP/AZ/AK Models: 20, 100, 500, 1000, 1000T 10PA, 1100, 1200, 12PA, 1300, 1400T, 14PA,

More information

Avenger Model 33M Installation & Operation Instructions

Avenger Model 33M Installation & Operation Instructions Avenger Model 33M Installation & Operation Instructions Manufacturing Contact Information A+ Corporation, LLC Call for expert product application assistance: 41041 Black Bayou Rd. Gonzales, LA 70737 Phone:

More information

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified

Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES. ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified Cash Valve TYPE G-4 PILOT OPERATED PRESSURE REDUCING REGULATOR FOR STEAM, AIR AND GASES ISSUED - MARCH 2001 CAVMC-0512-US-0208 ISO 9001 Certified TYPE G-4 DESCRIPTION FIG 2042 - Bronze FIG 2043 - Bronze

More information

Technical Data. UL Listing is based on the following criteria:

Technical Data. UL Listing is based on the following criteria: Worldwide Contacts www.tyco-fire.com DV-5 Deluge Valve with Trim Inch and 6 Inch (DN and DN5) General Description The TYCO DV-5 Deluge Valve with Trim is a diaphragm-style valve that depends upon water

More information

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY

For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum WARNING: FOR OUTDOOR USE ONLY For use with select HPC Fire Pits ONLY- refer to product catalog or website. 100K BTU Maximum : FOR OUTDOOR USE ONLY Small Tank LP Kit (STLPK) Installation & Operation Instructions Installation We suggest

More information

Pressure Regulator B-95

Pressure Regulator B-95 Pressure Regulator B-95 TYPE B WATER & AIR TYPE B INTERIOR WATER & AIR B SERIES VALVES DESTRIPTION The Cash Valve Series B pressure reducing and regulating valves are single seated, spring loaded, direct

More information

The OCV Series 8000 float control valves are designed to maintain a SERIES FEATURES

The OCV Series 8000 float control valves are designed to maintain a SERIES FEATURES The OCV Series 8000 float control valves are designed to maintain a desired level in a tank or reservoir by opening for filling the tank when fluid is below the high level point and closing tightly when

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

REFRIGERATION SYSTEM COMPONENTS

REFRIGERATION SYSTEM COMPONENTS REFRIGERATION SYSTEM COMPONENTS henrytech.com Conventional Oil Separators The function of an Oil Separator is to remove oil from the discharge gas and return it to the Compressor either directly or through

More information

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660

PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660 PILOT OPERATED PRESSURE VACUUM RELIEF VALVE MODEL 1660 Patent Protected Premium Seat Tightness to Set Pressure Snap or Modulating Valve Action Provides Ability to Meet Clean Air Act Requirements 600 TYPICAL

More information

Series C8/CR Cryogenic

Series C8/CR Cryogenic Triac C8/CR Series 3-Piece Ball feature a direct mount automation pad. The high quality investment castings feature a fully machined bore. The superior live loaded packing system is accomplished with Belleville

More information

Knife Gate Valves Pricelist 2017

Knife Gate Valves Pricelist 2017 Knife Gate Valves list 2017 Range of Knife Gate Valves * Manual and Actuated Knife Gate Valves * Accessories * Stafsjo Knife Gate Valves Knife Gate Valves list 2017 About Us All Valves Online Ltd are a

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance

CVI Valve Line. Exceeds the industry s highest standards for reliability and performance CVI Valve Line Exceeds the industry s highest standards for reliability and performance Available in the most standard models with the shortest lead times in the industry Exceptional quality every CVI

More information

REPLACEMENT PARTS LIST FOR MODELS:

REPLACEMENT PARTS LIST FOR MODELS: Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. MAIL TO: P.O. BOX 16347

More information

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls Type 1098-EGR and Type 1098H-EGR VL1000 FIELDVUE Pilot-Operated Valve Link Regulators Fisher Controls January 1982 Bulletin The Type 1098-EGR and Type 1098H-EGR regulators (figure 1) provide economical

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

CLASS TLP Pressure Reducing Valve

CLASS TLP Pressure Reducing Valve CLASS TLP Pressure Reducing Valve CLASS TLP Direct Acting Pressure Reducing Valve The Class TLP balanced direct acting pressure regulator is designed for use on installations that have varying inlet pressures

More information

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL

SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL SERVICE MANUAL MODEL BA600AMST-S1 BREATHING AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the service manual enclosed with this device. 2/05 GENERAL

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012

299H Series. Introduction. P.E.D. Categories. Specifications. Installation. Warning. Installation Guide English September 2012 Installation Guide English September 2012 299H Series Introduction This Installation Guide provides instructions for installation, startup, and adjustment of 299H Series regulators. To receive a copy of

More information

PRESSURE REGULATORS UPSTREAM DIFFERENTIAL PRESSURE. APPLICATION: For maintaining a constant differential pressure across meter.

PRESSURE REGULATORS UPSTREAM DIFFERENTIAL PRESSURE. APPLICATION: For maintaining a constant differential pressure across meter. PRESSURE REGULATORS UPSTREAM DIFFERENTIAL PRESSURE APPLICATION: For maintaining a constant differential pressure across meter. PRESSURE RANGE: Steel: 10 psig to 300 psig CAPACITY: Refer to Table of Contents.

More information

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control

Cash Valve. Type G-4. Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases. Flow Control Cash Valve Type G-4 Pilot Operated Pressure Reducing Regulator for Steam, Air and Gases Issued - March 2001 CAVMC-0512-US-0609 ISO 9001 Certified Flow Control Description FIG 2042 - Bronze FIG 2043 - Bronze

More information

D05 Pressure Regulating Valves

D05 Pressure Regulating Valves D05 Pressure Regulating Valves FEATURES PRODUCT DATA Noncorroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass. Balanced seat construction

More information

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID

REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID PART REPAIR PART NUMBER NUMBER DESCRIPTION 0137 ELE 0136 ELE 12 VOLT SOLENOID 0203 WHL 0250 WHL WHEEL HUB 0251 WHL AXLE 0252 WHL DUST CAPS 0253 WHL TIRE - 210 SP 0204 WHL 0211 WHL TIRE & WHEEL - SP 0250

More information

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections VALVCHEQ Backflow Preventers Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections Features General application The RP03 provides protection from both

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

2-port seat valves PN25 with externally threaded connections

2-port seat valves PN25 with externally threaded connections 4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with

More information

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.

MUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3. Installation Instructions manual MUELLER table of contents PAGE A-20808 General Information 2 Technical Data 3 Dimensions 4 A-20809 Non-Adjustable Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator

More information

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03 Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure

More information

Chlorinator. MODEL C-731 (Floor Mounted)

Chlorinator. MODEL C-731 (Floor Mounted) Chlorinator MODEL C-731 (Floor Mounted) CHLOROTECH Model C-731 is the advance technology Chlorinator designed to feed chlorine gas at a controlled rate. The flow rate of gas is maintained by constant positive

More information

Pilot valves for pilot operated servo valves

Pilot valves for pilot operated servo valves Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)

More information

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B

! WARNING. Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls INSTRUCTION MANUAL MM-110B INSTRUCTION MANUAL MM-110B Model PFC-1-G (direct acting) PFC-1-GR (reverse acting) Modulating Pneumatic Liquid Level Controls APPLICATIONS: Use with other pneumatic devices, for liquid level sensing in

More information

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant). Fittings for CO 2 Pipe Threads Pipe thread references quoted in this catalogue conform with the requirements specified in the latest issue and amendments of the following ISO Standards: ISO 7-1 (BS21)

More information

D05T Compact Design Pressure Regulating Valves

D05T Compact Design Pressure Regulating Valves D05T Compact Design Pressure Regulating Valves FEATURES PRODUCT DATA Non-corroding unitized cartridge contains all working parts and is easily replaceable. Includes built-in strainer and thermal bypass.

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

Bushing Viton O-ring (Other material available) Anti-Static Device

Bushing Viton O-ring (Other material available) Anti-Static Device Triac Ball Valves feature a high quality investment cast body and end. They are available in sizes from 1/4 to 3. Superior leak protection is accomplished by using our patented Pyramidal stem seal system

More information

Installation Instructions

Installation Instructions Installation Instructions S65-135 (Circular) S65-136 (Semi-Circular) Air Valve Retrofit For Non-Sectional Classic Washfountain Table of Contents.......................2-6 Metering Air Valve Parts List....................6

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP

More information

Technical Data Sheet T 2025

Technical Data Sheet T 2025 Self-operated emperature Regulators emperature Regulator ype 4 Valve closes when the temperature rises. emperature Regulator ype 4u Valve opens when the temperature rises. Balanced single-seated globe

More information

Model 4000 Pressure Controller

Model 4000 Pressure Controller FEATURES Multiple Configurations The 4000 series pressure controller can be configured into either proportional only or proportional plus reset mode with a minimum of parts. Rugged Design Die cast aluminum

More information

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator INSTRUCTION MANUAL CVS P37 LP Gas Reducing Regulator The CVS Controls P37 Regulator is a non-relieving, pressure reducing regulator suitable for use in LP gas applications (Natural Gas and Propane). As

More information

1805 Series Relief Valves

1805 Series Relief Valves Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion

More information

CROSS REFERENCE PARTS LIST T & S

CROSS REFERENCE PARTS LIST T & S 002711-40 KL41-Y006-KT Cold Spindle Assembly 002712-40 KL41-Y007-KT Hot Spindle Assembly 004R K50-Y011 Finger Hook Assembly 005312-40 KL50-Y027 Pedal Valve Bonnet Assembly 006678-45 K30-1000 Dipperwell

More information

North American Simplex Basket Strainers for Gas and Oil

North American Simplex Basket Strainers for Gas and Oil Combustion North American Simplex Basket Strainers for Gas and Oil A mesh lining (304 stainless standard or 316 stainless or monel special), either 20, 40 or 100 mesh, can be provided, depending on the

More information

WHEATLEY Series 500 Swing Check Valve

WHEATLEY Series 500 Swing Check Valve Document Number: TC003001-13 Revision: 02 WHEATLEY Series 500 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...5 INSTALLATION AND OPERATION

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level

More information

Y:\Machine Manuals & Spare Parts Lists\PARTS BREAKDOWN\Commercial CW Gas\HD850WS Page 1

Y:\Machine Manuals & Spare Parts Lists\PARTS BREAKDOWN\Commercial CW Gas\HD850WS Page 1 1.0 PIECE PARTS - parts listing 1 5311-0710 Nut 1 2 5443-2820 Hose Stem 1 3 6362-3950 O-Ring Seal 14.0x1.78 1 4 6414-2820 Strainer 1 5 6313-0030 Spring 2 6 5321-1980 Handhold 1 7 5066-2120 Cover 1 8 5363-1350

More information

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28 Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

Liquid Level Controllers

Liquid Level Controllers Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential

More information

Float valves Types SV 4, SV 5 and SV 6

Float valves Types SV 4, SV 5 and SV 6 Data sheet Float valves Types SV 4, SV 5 and SV 6 SV 4-6 are for use on the low pressure side as modulating liquid level regulators in refrigeration, freezing and air conditioning systems with ammonia

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

2-port and 3-port valves PN 16

2-port and 3-port valves PN 16 OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port

More information

Description Supply pressure Pressure range Connection Device Page max. bar bar thread

Description Supply pressure Pressure range Connection Device Page max. bar bar thread Pressure Regulators Supply pressure Pressure range onnection Device Page max. bar bar thread Maxi -Series, robust, interlockable 1 0. 1.8 / 17 G¼ - G1 R0, R1.0 made of plastic, also for liquids 1,5 0 4

More information

RC 195 Receiver-Controller

RC 195 Receiver-Controller Document No. 129-082 RC 195 Receiver-Controller Product Description The POWERS RC 195 Receiver-Controller is a pneumatic instrument that receives one, two or three pneumatic inputs. It produces a pneumatic

More information

Required Indoor Draft Hood. Optional Outdoor Vent Cap

Required Indoor Draft Hood. Optional Outdoor Vent Cap Pump-Mounted Water Heaters B4 - Copper Brute Water Heater Convertible Sizes 175,000-399,000 BTU/hr Indoor/Outdoor Sizes 500,000-1,825,000 BTU/hr Up to 82% Thermal Efficiency The unit will be designed and

More information

FLOAT OPERATED LEVEL CONTROLLER

FLOAT OPERATED LEVEL CONTROLLER PNEUMATIC LEVEL SWITCH NO RELAY APPLICATION: Liquid level controller for oil and gas separators, water knockouts, gas scrubbers and accumulators. FEATURES: Push-button dump valve override standard Float

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 1, 01 VGG VGD0 VGD0 Description Only when assembled to Series SKP actuators

More information

Crest Heating Boilers FBN(L) Series &

Crest Heating Boilers FBN(L) Series & Replacement Parts List PARTS & SERVICE DEPARTMENT Nashville, Tennessee 877-554-5544 Fax: 615-882-2918 parts_team@lochinvar.com www.lochinvar.com Crest Heating Boilers FBN(L) 751-2001 Series 100-101 & 110-111

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

WaterSource Heat Pump Hose Kit Performance Specification-Summary

WaterSource Heat Pump Hose Kit Performance Specification-Summary WaterSource Heat Pump Hose Kit Performance Specification-Summary AUTOMATIC & MANUAL BALANCING HOSE KITS Contractor shall provide and install Hays Hose Kits. Each kit, shall include a Hays 2500 Series Mesurflo

More information

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM

More information

FLOAT OPERATED LEVEL CONTROLLER

FLOAT OPERATED LEVEL CONTROLLER PNEUMATIC LEVEL SWITCH APPLICATION: Liquid level controller for oil and gas separators, water knockouts, gas scrubbers and accumulators. FEATURES: Rated for 2000 psi working pressure Push-button dump valve

More information

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,

More information

Standard Specifications

Standard Specifications NARM, 2 Ways of Connection Small Size Pressure Gauge ø5mm Reverse flow function available on the standard model Space Saving -B2 NARM-6A-NG Standard Specifications Fluid Proof pressure psig (MPa) Max.

More information

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders

CLEAN AGENT FIRE EXTINGUISHING SYSTEM MX 1230 Extinguishing Agent Cylinders The technical data described herein is for components of the Minimax Fire Products MX 30 Clean Agent System. For design, installation, and operation instructions, refer to the latest edition of the original

More information

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts

Series V48. 3-Way Pressure Actuated Modulating Valves. Product Bulletin. Features. Pressure balanced design. Free movement of all parts Series V48 -Way Pressure Actuated Modulating Valves Product Bulletin These Water Valves are especially designed for condensing units cooled either by atmospheric or forced draft cooling towers. They may

More information

Related Products: Auto Drain Valve. Model/Specifications. Model

Related Products: Auto Drain Valve. Model/Specifications. Model Related Products: Auto Drain Valve /600 Drainage is automatically discharged in a reliable manner, without requiring human operators. Highly resistant to dust and corrosion, operates reliably, and a bowl

More information