DESIGN ENVELOPE 6800 G 1 DUTY PUMP

Size: px
Start display at page:

Download "DESIGN ENVELOPE 6800 G 1 DUTY PUMP"

Transcription

1 DESIGN ENVELOPE 68 G 1 DUTY PUMP AND 1 STANDBY, DOMESTIC WATER BOOSTER WIT STANDBY N122s N192s SUBMITTAL File No: Date: june 27, 217 Supersedes: new Date: new Job: Representative: Engineer: Contractor: Order by: Submitted by: Approved by: Date: Date: Date: pump design data motor design data No. of pumps: Tag: p: rpm: 6 Total package capacity: USgpm (L/s) Frame size: Enclosure: odp tefc Pump capacity: USgpm (L/s) ead: ft (m) Volts: ertz: 6 z Pase: Liquid: Viscosity: Efficiency: nema premium Temperature: f ( c) Specific gravity: note: Test tolerance according to iso 996 Grade 2b ±8% on measured flow and ±5% on measured ead optional eader flange connections Suction ansi 125/15 Discarge ansi 125/15 ansi 25/ connection orientation Suction Rigt Left Discarge Rigt Left drive data Enclosure: ul type 12 emi/rfi control: Integrated filter designed to meet en618- armonic suppression: Integrated dc link reactors Cooling: Fan-cooled troug back cannel Ambient temperature: -1 c to +45 c up to 1 meters above sea level (-14 f to +11 f, 28 ft) control panel specifications nema type enclosure: r (opt) 4 (opt) 12 (std) Low suction sutdown and auto re-start Main disconnect wit interlock Fused motor protection Fused control circuit transformer Power on indication Motor run indication Virtual -o-a for eac pump No-flow sutdown and automatic alternation Soft fill mode Pressure setback mode ul or csa labeled Field adjustable set points, alarms and timers Flas memory storage No-flow pressure optimization optional equipment

2 submittal n122s - n192s Design envelope 68 g 2 design envelope capability data envelope curve max flow max ead best eff % eac motor frame size pump number usgpm (L/s) ft (m) point (bep) motor p odp tefc N122S VMS-12B 75.4 (4.76) 97.6 (29.7) 67.6% 2 56C N12S VMS-1B 75.6 (4.77) 147. (44.9) 67.6% 182TC N142S VMS-14BE 7.2 (4.4) (59.9) 67.6% 184TC N152S VMS-15B 75.6 (4.77) (74.8) 67.6% 5 184TC N162S VMS-16B 74.2 (4.68) (89.8) 67.6% 5 184TC N192S VMS-19B 74.4 (4.69) (15.5) 67.6% TC N1122S VMS-112B 57. (.62) (18.6) 67.6% 1 215TC N1162S VMS-116B 48.8 (.8) 79.1 (24.8) 67.6% TC N1512S VMS (11.7) 86.9 (26.5) 68.7% 5 184TC N15222S VMS (11.7) (45.4) 68.7% TC N1522S VMS (11.7) 27. (72.2) 68.7% 1 215TC N1542S VMS (11.7) 14.6 (95.9) 68.7% TC N1552S VMS (15) (17.1) 68.7% 2 256TC N1562S VMS (11.69) (166.5) 68.7% TSC N1612S VMS-451E (17.5) (5.6) 8.1% TC N16212S VMS (17.66) 2.4 (61.1) 8.1% TC N162S VMS (17.81) 62.8 (11.6) 8.% TSC N1622S VMS (17.81) 29.2 (88.5) 8.1% 2 256TC N16412S VMS (17.81) 445. (15.6) 8.1% 286TSC N1712S VMS-641E 92.6 (24.77) 12.2 (7.6) 84.7% 1 215TC N1722S VMS (25.6) (76.7) 84.7% TSC N17212S VMS (25.6) (69.1) 84.7% 2 256TC N1722S VMS (25.6) 29.2 (1.) 84.7% 286TSC N1812S VMS-151B (7.7) 62.6 (19.1) 72.5% 2 56C N1822S VMS-152B (7.9) (8.) 72.5% 5 184TC N182S VMS-15BE (7.42) (57.9) 72.5% 5 184TC N1842S VMS-154BE (7.42) 25.1 (77.1) 72.5% TC N1852S VMS-155B (7.8) 16.4 (96.4) 72.5% 1 215TC N1872S VMS-157B (7.42) (15.) 72.5% TC N1812S VMS-151B (7.46) 69.9 (195.) 72.5% 2 256TC N18122S VMS-1512B (7.46) (24.1) 72.5% TSC N1912S VMS-21B 1.7 (8.44) 71.8 (21.9) 7.% 182TC N1922S VMS-22B 11. (8.28) 14.5 (4.7) 7.% 5 184TC N192S VMS-2B 11. (8.28) (66.) 7.% TC Notes: 1 nsf 61 and nsf 72 certified complete package assembly. 2 Standard rigt and connection orientation illustrated, please indicate alternate connection orientation, if required. All pumps are equal. 4 Standard grooved eader connections. Optional flanged ansi 15# or # connections available. 5 Optional tank sipped loose, installed by oters.

3 Design envelope 68 g submittal n122s - n192s booster model N122S N12S N142S N152S N162S N192S N1122S N1162S N1512S N15222S N1522S N1542S N1552S N1562S N1612S N16212S N162S N1622S N16412S N1712S N1722S N17212S N1722S N1812S N1822S N182S N1842S N1852S N1872S N1812S N18122S N1912S N1922S N192S a b c max d e f g j j1 max working pressure weigt inces (mm) psi (bar) lbs (kg) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 562 (255) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 61 (272) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 66 (275) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 68 (276) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 61 (278) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 764 (47) (175) (78) (156) (157) (11) (424) (5) (55) (191) (21) 6 (25) 95 (41) (175) (78) (156) (157) (11) (424) (5) (55) (191) (21) 6 (25) 12 (46) (1228) (148) (156) (172) (11) (574) (5) (55) (229) (229) 22 (16) 91 (41) (1228) (148) (156) (172) (11) (574) (5) (55) (229) (229) 22 (16) 12 (464) (1228) (148) (156) (172) (11) (574) (5) (55) (229) (229) 22 (16) 1285 (58) (1228) (148) (156) (172) (11) (574) (5) (55) (229) (229) 22 (16) 112 (595) (1228) (148) (156) (172) (11) (574) (5) (55) (229) (254) 6 (25) 1566 (71) (1228) (148) (1578) (172) (11) (574) (5) (55) (229) (254) 6 (25) 1984 (9) (15) (1155) (156) (27) (11) (574) (5) (55) (279) (279) 22 (16) 1162 (527) (15) (1155) (156) (27) (11) (574) (5) (55) (279) (279) 22 (16) 147 (652) (15) (1155) (156) (27) (11) (574) (5) (55) (279) (279) 22 (16) 29 (948) (15) (1155) (156) (27) (11) (574) (5) (55) (279) (279) 22 (16) 1685 (764) (15) (1155) (1624) (27) (11) (574) (5) (55) (279) (18) 6 (25) 2157 (978) (15) (1246) (156) (27) (11) (574) (5) (55) (279) (279) 22 (16) 1645 (746) (15) (1246) (156) (27) (11) (574) (5) (55) (279) (279) 22 (16) 26 (146) (15) (1246) (156) (27) (11) (574) (5) (55) (279) (279) 22 (16) 192 (86) (15) (1246) (156) (27) (11) (574) (5) (55) (279) (279) 22 (16) 241 (162) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 551 (25) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 587 (266) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 627 (285) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 77 (4) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 911 (41) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 981 (445) (175) (78) (156) (157) (11) (424) (5) (55) (191) (21) 6 (25) 1215 (551) (175) (78) (156) (157) (11) (424) (5) (55) (191) (21) 6 (25) 162 (74) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 586 (266) (175) (78) (156) (157) (11) (424) (5) (55) (191) (191) 22 (16) 587 (266) 42.4 (175).7 (78) (156) 6.19 (157) 4.1 (11) (424) 1.97 (5) (55) 7.5 (191) Note: All dimensions are inces (mm), tolerances are (+/-) ½" (12 mm) unless oterwise specified. 7.5 (191) 22 (16) 71 (1)

4 submittal n122s - n192s Design envelope 68 g 4 performance curve - vms 1b q [l/min] p [psi] [ft] vms 116/15 p vms 1b - 6 z - 45 rpm [m] 8 vms 115/15 p 24 vms 114/15 p vms 112/1 p vms 111/1 p vms 11/1 p vms 19/7.5 p vms 18/7.5 p vms 17/7.5 p vms 16/5 p vms 15/5 p 8 2 vms 14/5 p 58 1 vms 1/ p vms 12/2 p 4 vms 11/1 p p 2 [p] % Single Impeller p q [m /] 8 6 [%] 4 [ft] [m] note: Pump curves are sown for information purpose only and sould not be used for selection. Individual pump curves don t represent te performance of a complete package as tey ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong s website for a detailed performance envelope for te specific booster model.

5 Design envelope 68 g submittal n122s - n192s 5 performance curve - vms 15b q [l/min] p [psi] vms 1512b/25p [ft] vms 15b - 6 z - 5 rpm [m] 8 vms 1511b/25p vms 151b/2p vms 159b/2p 2 6 vms 158b/2p 22 5 vms 157b/15p vms 156b/15p 12 vms 155b/1p 116 vms 154b/1p 8 2 vms 15b/7.5p 58 1 vms 152b/5p vms 151b/2p 4 p 2 [p] [ft] % Single impeller p q [m /] [%] [m] note: Pump curves are sown for information purpose only and sould not be used for selection. Individual pump curves don t represent te performance of a complete package as tey ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong s website for a detailed performance envelope for te specific booster model.

6 submittal n122s - n192s Design envelope 68 g 6 performance curve - vms 2b q [l/min] p [psi] 48 9 [ft] vms 21/25 p vms 2b - 6 z - 45 rpm 28 [m] vms 29/25 p vms 28/2 p vms 27/2 p vms 26/15 p vms 25/15 p vms 24/1 p vms 2/7.5 p vms 22/5 p vms 21/ p 4 p 2 [p] [ft] % Single Impeller p 4q [m /] [%] [m] note: Pump curves are sown for information purpose only and sould not be used for selection. Individual pump curves don t represent te performance of a complete package as tey ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong s website for a detailed performance envelope for te specific booster model.

7 Design envelope 68 g submittal n122s - n192s 7 performance curve - vms 2 5 (m) 4 11 (ft) 1 vms 21-1 min. flow vms 2-6 z - 5 rpm vms vms vms vms vms vms vms vms 2-2 vms nsp(ft) nsp(m) 1 vms eff.% q m / note: Pump curves are sown for information purpose only and sould not be used for selection. Individual pump curves don t represent te performance of a complete package as tey ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong s website for a detailed performance envelope for te specific booster model.

8 submittal n122s - n192s Design envelope 68 g 8 performance curve - vms (m) (ft) 8 vms min. flow vms 45-6 z - 5 rpm vms vms vms vms vms vms vms 451 vms nsp(ft) nsp(m) q m / eff.% note: Pump curves are sown for information purpose only and sould not be used for selection. Individual pump curves don t represent te performance of a complete package as tey ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong s website for a detailed performance envelope for te specific booster model.

9 Design envelope 68 g submittal n122s - n192s 9 performance curve - vms (m) 6 (ft) vms 644 min. flow vms 64-6 z - 5 rpm vms vms 64 vms vms 642 vms vms vms nsp(ft) nsp(m) eff.% q m / note: Pump curves are sown for information purpose only and sould not be used for selection. Individual pump curves don t represent te performance of a complete package as tey ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong s website for a detailed performance envelope for te specific booster model.

10 submittal n122s - n192s Design envelope 68 g 1 4 j discarge connection grooved standard c max b f 5 d g 1 e j 1 a suction connection grooved standard Models N122S - N192S toronto buffalo birmingam +44 () item description 1 Stainless steel suction eader 2 Stainless steel discarge eader Pump wit integrated ivs controls 4 Control panel wit plc 5 Suction isolation valve 6 Grooved connection 7 Pressure gauge 8 Pressure transducer 9 Pressure gauge isolation valve 1 Stainless steel base and panel support 11 Plug pipe 12 Flo-Trex valve mancester +44 () bangalore +91 () sangai são paulo armstrong fluid tecnology establised 194 armstrongfluidtecnology.com

E.2 Series. High efficiency circulator. Technical overview

E.2 Series. High efficiency circulator. Technical overview E.2 Series High efficiency Technical File No:.165 Date: june 05, 2017 Supersedes:.165 Date: october 08, 2015 contents Motor data 4 Technical data 4 Materials of construction 4 Dimensions and weights 5

More information

Design Envelope Booster. Sequence of operation

Design Envelope Booster. Sequence of operation Design Envelope Booster Sequence of operation File No: 62.835 Date: february 11, 2015 Supersedes: 62.835 Date: july 11, 2014 sequence of operation Design Envelope Booster 2 general The packaged domestic

More information

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Air Technology Systems, Inc. Table of Contents Section - 1 Table

More information

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz

GRUNDFOS DATA BOOKLET. Hydro Solo-E. Complete pressure boosting systems 50/60 Hz GRUNDFOS DATA BOOKLET Complete pressure boosting systems 5/6 z Contents Product data Performance range 3 Operating conditions Inlet pressure Type key Product range 5 Construction 5 Installation 5 Mechanical

More information

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers

Glycol Systems. Engineering Manual. 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Glycol Systems Engineering Manual 1/2 to 10 Hp Pumps 3 to 190 Tons Drycoolers (60 Hz Data) Pump Packages & Remote Outdoor Drycoolers Stulz Table of Contents Section - 1 Table of Contents... 1-1 Glycol

More information

KSB Delta Compact Type Series Booklet

KSB Delta Compact Type Series Booklet Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,

More information

SINGLE VALVE WITH LOW-FLOW BYPASS

SINGLE VALVE WITH LOW-FLOW BYPASS CONTROL VALVES Pressure Reducing Valve Sizing Guide Sizing pilot operated reducing valves is not a complicated process. It starts with determining requirements and following these guidelines in valve size

More information

Valve Proving System VDK 200 A S02

Valve Proving System VDK 200 A S02 Valve Proving System VDK 200 A S02 Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

Valve Proving System VDK 200 A S06*

Valve Proving System VDK 200 A S06* Valve Proving System VDK 200 A S06* Valve proving system with the following approvals. UL Recognized File # MH17004 CSA Certified File # 1637485 CSA Requirement No. 4-01 (USA) Technical Information Letter

More information

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10

VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES 10 / ED VPPL VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS FOR INTERMEDIATE PRESSURE SERIES OPERATING PRINCIPLE The VPPL are variable displacement axial-piston pumps with variable swash plate, suitable for applications

More information

KSB Delta Compact Type Series Booklet

KSB Delta Compact Type Series Booklet Pressure Booster System KSB Delta Compact Type Series Booklet Legal information/copyright Type Series Booklet KSB Delta Compact All rights reserved. The contents provided herein must neither be distributed,

More information

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA 62-10 Single-Phase Pad-Mounted Distribution Catolog Transformers Section Howard Industries, Inc. Certifi ed to ISO 9001:2015 62-10 Single-Phase Pad-Mounted Distribution Transformers 5-500 KVA 10002179

More information

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design

Variable Displacement Double Pump A20VO. Series 1, for open circuits Axial piston - swashplate design, Back to back - design Brueninghaus Hydromatik Series 1, for open circuits Axial piston - swashplate design, Back to back - design RE 93100/02.97 Sizes 60...260 Nominal Pressure up to 350 bar Peak Pressure up to 400 bar Preliminary

More information

Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty

Hazardous Duty Explosion Proof, Three Phase, Blue Chip Severe Duty Applications: Hazardous Duty Explosion Proof, Three Phase Class I Groups C & D, Class II Groups F & G, Rigid Base installed in hazardous environments as defined by the motor's explosion proof class and

More information

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL

MOYNO FLUID DETECTION CONTROL SERVICE MANUAL. Section: ACCESSORIES. Page: 1 of 8 Date: May 1, 1998 GENERAL MOYNO Section: ACCESSORIES Page: 1 of 8 Date: May 1, 1998 SERVICE MANUAL FLUID DETECTION CONTROL GENERAL The Moyno Fluid Detection Control prevents unnecessary loss of production time or repair costs to

More information

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm

E 328 E 498 Tank top mounting Connection up to G1½ / -24 SAE and SAE 2 Nominal flow rate up to 600 l/min / gpm Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ / - SE and SE Nominal flow rate up to 6 l/min / 8. gpm Description pplication For operation in units with hydrostatic drives, when

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized

More information

BUBBLER CONTROL SYSTEM

BUBBLER CONTROL SYSTEM BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air

More information

Automatic Control Unit. Controlmatic E. Type Series Booklet

Automatic Control Unit. Controlmatic E. Type Series Booklet Automatic Control Unit Controlmatic E Type Series Booklet Legal information/copyright Type Series Booklet Controlmatic E All rights reserved. The contents provided herein must neither be distributed, copied,

More information

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof

More information

T Y P E V S A B M S E W A G E P U M P

T Y P E V S A B M S E W A G E P U M P Pe r fo r m a n ce C h a r t s 11 1 D R Y P I T S B U L L E T I N 2 3 9 8 7 6 5 4 3 2 1 12 11 1 / 4 1 1 / 2 9 3 / 4 9 5% 3 HP 5 HP 7 1/2 HP 1 HP 76% 5% C u r v e P a g e V S A B M - 4 1 1 5 R P M M O D

More information

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series

Safety Shutoff Valves MVD/6 Series MVDLE/6 Series Safety Shutoff Valves /6 Series /6 Series Normally closed safety shutoff valve with the following approvals. UL Listed UL 49 File # MH16 CSA Certified ANSI Z1.1 CSA 6. Marked C/I File # LR 111 FM Approved

More information

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series

Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure DMV-D/604L Series DMV-DLE/604L Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Listed

More information

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series

Dual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked

More information

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA

More information

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor.

On-Off switch. Selectable manual control for commissioning. Remote start input for control via an irrigation controller, or external sensor. SPEEDMAN VARIABLE SPEED PUMP SET VARIABLE SPEED PUMP SET PRODUCT DESCRIPTION Variable speed / constant pressure system consisting of a Davey VM vertical multistage pump with Speedman controller, VSD unit,

More information

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI

All technical data may be changed MADE IN ITALY BY NARDI COMPRESSORI PACIFIC MX NITROX BREATHING AIR according to DIN EN 12021 MAX OXYGEN 40% DELIVERY l/min 600 m 3 h 36 PRESSURE BAR 225 PSI 3250 Quality system certified to iso 9001 BREATHING AIR is a product line that

More information

FOAM TANK (1/2) DATA SHEET

FOAM TANK (1/2) DATA SHEET FIRE FIGHTING EQUIPMENT DATA SHEET FOAM TANK (1/) DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER : ITEM NO. : 0 PROJECT : QUANTITY : 0 LOCATION : SERVICE : FOAM SYSTEM 0 05 CODE & STANDARDS

More information

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Master Control Systems, Inc. Variable Speed Fire Pump Controllers Master Control Systems, Inc. Variable Speed Fire Pump Controllers Meets NFPA 20-2013 UL/FM Listed and Approved for fire protections 1 Why Variable Speed? Huge Sprinkler System and Standpipe Cost Savings

More information

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP

OPERATING INSTRUCTIONS MANUAL FOR QACV PNEUMATIC DOSING PUMP This operating instructions contains safety information that if ignored can endanger life or result in serious injury. They are indicated by this icon. Use of this pump with radioactive chemicals is forbidden!

More information

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series

Dual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA

More information

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Differential pressure switch / Lube oil protection control MP 54 and MP 55 Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors

More information

NGP-250/500 Nitrogen Generator Quick Start Guide

NGP-250/500 Nitrogen Generator Quick Start Guide NGP-250/500 Nitrogen Generator Quick Start Guide Version: A July 2013 Potter Electric Signal Company, LLC 5757 Phantom Dr., Suite 125 P. O. Box 42037 Hazelwood, MO 63042 Phone: (314) 595-6900 Document

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA

O.K. Safety first. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA CDN USA HPSV 10020/604 High Pressure Safety Shutoff Valve Installation Instructions USA CDN Table of Contents Table of Contents...Page 1 Approvals...Page 1 Attention...Page 1 Specification...Page 2 Installation

More information

SyncroFlo Municipal University and Hydraulic Institute, Pump Systems Optimization

SyncroFlo Municipal University and Hydraulic Institute, Pump Systems Optimization SyncroFlo Municipal University and Hydraulic Institute, Pump Systems Optimization COURSE SYLLABUS September 16 th 18 th, 2013 9/16/13 Day One Hydraulic Institute Workshop (8:30am) PUMP SYSTEMS OPTIMIZATION:

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min

E 328 E 498 Tank top mounting Connection up to G1½ and SAE 2 Nominal flow rate up to 600 l/min Return-Suction Filters E 8 E 98 Tank top mounting Connection up to G½ and SE Nominal flow rate up to 6 l/min Description pplication For operation in units with hydrostatic drives, when the return flow

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

Automatic Control Unit. Controlmatic E.2. Type Series Booklet

Automatic Control Unit. Controlmatic E.2. Type Series Booklet Automatic Control Unit Controlmatic E.2 Type Series Booklet Legal information/copyright Type Series Booklet Controlmatic E.2 All rights reserved. The contents provided herein must neither be distributed,

More information

Goulds 3296 EZMAG. Chemical Process Pump

Goulds 3296 EZMAG. Chemical Process Pump Goulds 3296 EZMAG Chemical Process Pump 3296 EZMAG Chemical Process Pump Capacities to 700 gpm (160 m3/h) Heads to 620 ft (189 m) Temperatures to 535 F (280 C) Pressures to 275 PSIG Performance Features

More information

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve.

BERMAD Irrigation. IR-100 hyflow Basic Valve. Basic Valve. Basic Valve IR- Yflow Basic Valve Te BERMAD basic Model IR- Yflow diapragm actuated, ydraulically operated valve is at te leading edge of control valve design. It combines simple and reliable construction

More information

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

V311. Venta. Three-way Plug Valve, Flanged PN 16

V311. Venta. Three-way Plug Valve, Flanged PN 16 1 Three-way Plug Valve, Flanged PN 16 can be used in a wide range of applications, such as heating, cooling, air handling and domestic hot water systems. Soft EPDM seals provide tight shut off. The valve

More information

Installation and commissioning instructions 255 series and 256 series

Installation and commissioning instructions 255 series and 256 series Installation and commissioning instructions 255 series and 256 series Table of contents 1 General information... 3 1.1 About these instructions... 3 1.2 About this product... 3 1.3 Appropriate usage...

More information

2 I All-Flo Pump Co.

2 I All-Flo Pump Co. 2 I All-Flo Pump Co. 3I All-Flo Pump Co. Model Designation Matrix PRODUCT SERIES PUMP SIZE FLUID CONNECTI INTERM INNER CHAM ON TYPE FLUID C HAMBER MANIFOLDS EDI A TE/ BER O-RINGS VAL VE SEAT VALVE/BAL

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.

More information

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications

Dual displacement motor A10VM Plug-in dual displacement motor A10VE for open and closed circuit applications Replaces: 04.95 Dual displacement motor 10VM Plug-in dual displacement motor 10VE for open and closed circuit applications Size 28-60 Series 5 Nominal pressure 280 bar Peak pressure 350 bar 10VM Contents

More information

BACK PRESSURE / SUSTAINING

BACK PRESSURE / SUSTAINING SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series

More information

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18

Simple Set Max. Pressure Independent Control Valves 2 Way 2-1/ /09/18 The Bray Simple Set Max is a flanged pressure independent control (PIC) valve designed for a wide variety of hot water and chilled water control applications. The SSM Series combines high rangeability

More information

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series

Dual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each

More information

Required Indoor Draft Hood. Optional Outdoor Vent Cap

Required Indoor Draft Hood. Optional Outdoor Vent Cap Pump-Mounted Water Heaters B4 - Copper Brute Water Heater Convertible Sizes 175,000-399,000 BTU/hr Indoor/Outdoor Sizes 500,000-1,825,000 BTU/hr Up to 82% Thermal Efficiency The unit will be designed and

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low noise

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid

More information

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25

More information

Axial piston pumps type PVC

Axial piston pumps type PVC www.atos.com Table TA16SK-1/E Axial piston pumps type PV variable displacement, by a full line of mechanical controls PV are variable displacement axial piston pumps for medium pressure operation, low

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11

Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I

More information

ScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m

ScanFoam. Cleaning Equipment ApS. w w w. s c a n f o a m. c o m ScanFoam Cleaning Equipment ApS w w w. s c a n f o a m. c o m Units List of Equipment 2015-06A ScanFoam ApS Skanderborg Denmark Phone: +45 86 57 25 99 Fax: +45 86 57 20 86 E-mail: anders.christensen@scanfoam.com

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

2-port seat valves PN25 with externally threaded connections

2-port seat valves PN25 with externally threaded connections 4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with

More information

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.

More information

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series

Dual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized

More information

take a deep breath... Dependable high quality breathing air compressors

take a deep breath... Dependable high quality breathing air compressors take a deep breath... Dependable high quality breathing air compressors IN THE LEAGUE OF ITS OWN... SEACOMAIR manufacture a dependable high quality breathing air compressors, designed for continuous duty

More information

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15

MLS Series Liquid Level Switches. Installation and Operations Manual Section 15 MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right

More information

For Multi-Parameter Meters see mvx

For Multi-Parameter Meters see mvx VORTEX IN-LINE FLOW METERS Design Features For Multi-Parameter Meters see mvx Principles of Operation VX No moving parts to wear or fail. Electronics can be remotely mounted up to 30.5 m (0 ft). No fluid

More information

FILTER BYPASS CONTROL

FILTER BYPASS CONTROL Differential Control Valve Series 110 The Series 110 Differential Control Valve is designed to accurately control the pressure difference between any two points. In some systems this means the valve remains

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following:

PART 1 GENERAL..2 Components of the gas chlorination system include, but are not limited to the following: PART 1 GENERAL 1.1 DESCRIPTION.1 This section includes the supply, delivery and installation, testing and placement into operation of a gas chlorination system, and appurtenances as specified herein and

More information

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series

Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates

More information

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42

Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 Data sheet Electric regulating valves Type CCMT 2 - CCMT 8 / CCMT 16 - CCMT 42 The CCMT is an electrically operated valve designed specifically for operation in CO 2 systems. The CCMT valve concept is

More information

Raising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings

Raising the bar. Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings Raising the bar Philips Advance Optanium high efficiency instant start T8 ballasts have set new standards for maximizing energy savings Philips Advance Optanium high-efficiency electronic ballasts are

More information

Master Control Systems, Inc. Variable Speed Fire Pump Controllers

Master Control Systems, Inc. Variable Speed Fire Pump Controllers Master Control Systems, Inc. Variable Speed Fire Pump Controllers Meets NFPA 20-2019 UL/FM Listed and Approved for fire protections * Pressure Limiting Control * Suction Limiting Control Why Variable Speed?

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Pressure Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL File # MH 668 CSA Certified CSA C. No. LR File # 07 FM Approved Class 0, 0 File # J.I. Y9A9.AF Commonwealth of Massachusetts

More information

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm

E 084 Tank top mounting Connection up to G1 / -16 SAE Nominal flow rate up to 80 l/min / 21.1 gpm Return-Suction Filters E 08 Tank top mounting Connection up to G / -6 SE Nominal flow rate up to 80 l/min /. gpm Description pplication For operation in units with hydrostatic drives, when the return flow

More information

VSD03M DIRECTIONAL CONTROL VALVES

VSD03M DIRECTIONAL CONTROL VALVES NFPA SIZE D03 TYPICAL PERFORMANCE SPECIFICATIONS Performance is measured on a four-way circuit (full circuit). Performance may e reduced from that shown if a three-way circuit (half circuit) is used, i.e.

More information

DEWATERING PUMP SOLUTIONS. Pneumatic pumps

DEWATERING PUMP SOLUTIONS. Pneumatic pumps DEWATERING PUMP SOLUTIONS Pneumatic pumps PUMP UP YOUR BUSINESS A pneumatic pump is a great choice when failure is not an option. They re easy to use, safe and can handle almost anything you throw at them.

More information

Residential Pressure Booster Systems

Residential Pressure Booster Systems Residential Pressure Booster Systems HOW IT WORKS When the pressure available is insuffi cient it is necessary to install a boosting system. FLUX BOOSTING SYSTEM starts and stops according to the user

More information

Model 130M Pneumatic Controller

Model 130M Pneumatic Controller Instruction MI 017-450 May 1978 Model 130M Pneumatic Controller Installation and Operation Manual Control Unit Controller Model 130M Controller is a pneumatic, shelf-mounted instrument with a separate

More information

3-way control valves VK 3

3-way control valves VK 3 Data sheet 3-way control valves VK 3 Description / Application VK 3 valves are a range of 3 port high specification flanged valves for chilled water, LPHW, MPHW, HPHW (low, medium or high pressure hot

More information

Pressure Switch for gas and air GGAO-A4

Pressure Switch for gas and air GGAO-A4 Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Model MTB-ASME Horizontal Bladder Tanks

Model MTB-ASME Horizontal Bladder Tanks DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump

PTF4 Pivotrol Pump (patented) version Dual Mechanism - Pressure Powered Pump Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

AIR CONDITIONERS WA14**W SERIES

AIR CONDITIONERS WA14**W SERIES FORM NO. A66-225 REV. 3 AIR CONDITIONERS Features Outdoor air conditioner designed for ground level or rooftop installations. These units offer comfort and dependability for single, multi-family and light

More information

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604

Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21

More information

PAINTBALL

PAINTBALL 02012 www.nuvair.com PAINTBALL Table of Contents Ordering Ordering...3 High Pressure Compressors Coltri/Nuvair Portable... Coltri/Nuvair Compact Portable...5 Coltri/Nuvair Standard Electric...6 Coltri/Nuvair

More information

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited

Gas Furnaces 95AF2V. Warranty Heat Exchanger - 20 Year Limited Parts - 5 Year Limited PRODUCT SPECIFICATIONS INSTALLATION OPTIONS Available in Upflow/Horizontal and Counterflow models HEAT EXCHANGER Aluminized steel primary heat exchanger with crimped non-welded construction Stainless steel

More information

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.

More information

Review of the Hall B Gas System Hardware. George Jacobs

Review of the Hall B Gas System Hardware. George Jacobs of the Hardware George Jacobs DSG Staff 2 Hall B Gas Utilities for detectors Drift Chamber (DC) Low Threshold Cherenkov Counter (LTCC) Micromegas Vertex Tracker (MVT) Forward Tagger (FT) Ring Imaging Cherenkov

More information

Model MTB-ASME Vertical Bladder Tanks

Model MTB-ASME Vertical Bladder Tanks DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

Liquid Level Controllers

Liquid Level Controllers Liquid Level Controllers ALL PUMPS LLC-2Y For both pump up and down control. Variable On/Off set points. NDP-15/20/25/32, DP-10/15 & *NDP-40/50/80 LLC-1 Pump up and down versions available. 6 to 12 differential

More information

Phuel Portable Control Units

Phuel Portable Control Units Phuel Portable PCE Control Unit Pressure Test Unit c/w Chart Recorder Triple Wireline BOP The Phuel range of Air Driven Portable provide all the control functions required for well intervention operations

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information