2 FACTS ON DEBs LEGFLOW RX/OTW PACLITAXEL RELEASING PTA BALLOON DILATATION CATHETER. WITH UNIQUE SAFEPAX DRUG COATING TECHNOLOGY

3 SUCCESSFUL PREVENTION AND TREATMENT OF RESTENOSIS AFTER PERIPHERAL INTERVENTION. 02

4 LEGFLOW RX/OTW Paclitaxel Releasing Peripheral Balloon Dilatation Catheter THE LEGFLOW BALLOON DRUG COATING QUALITY IS A MAJOR STEP BEYOND CONTEMPORARY FIRST AND SECOND GENERATION DEB COATINGS. Effective DEB PTX drug-transfer LEGFLOW SAFETY: Only the smallest PTX crystals appear safe enough to bear no risk of adverse embolic or thrombotic effects or obstructing the smaller distal vasculature. LEGFLOW ensures a high patient safety by non-visible 0.1µm smallest PTX particles leapfrogging ahead of µm large Paclitaxel crystals on most other DEBs. THE UNIQUE LEGFLOW INNOVATION: The step beyond contemporary first and second generation DEB coatings which had to compromise on vulnerable balloon coating mixtures out of a high water soluble drug excipient with relatively large PTX crystals. LEGFLOW COATING INTEGRITY: The indestructible, structural balloon coating integrity, combined with a protective drug coating finesse, does not require the use of an extra insertion tool. LEGFLOW SAFEPAX PERFORMANCE: Consistent and predictable drug delivery to the artery lesion site results in a homogenous and maximized drug absorption into the arterial tissue. LEGFLOW PROTECTIVE BALLOON COATING: The LEGFLOW Paclitaxel balloon surface coating cannot be wiped or fall off the balloon during catheter preparation, insertion or manipulation. LEGFLOW prevents endangerment of cathlab personnel, and guarantees a safe and predictable drug delivery to the target lesion site. 03

5 LEGFLOW RX/OTW 0.1µm UNSURPASSED INVISIBLY SMALL TRANSLUCENT PTX PARTICLES. Paclitaxel transfer into the vessel wall for clinically effective antiproliferative restenosisprevention. Paclitaxel inhibits SMC proliferation and significantly reduces neointimal hyperplasia. The LEGFLOW RX/OTW is indicated for the treatment of: critical limb ischemia (CLI) de-novo and restenotic lesions of the SFA popliteal artery and BTK (Below-The-Knee) artery lesions 04

6 The Paclitaxel particle size matters! DEB SAFETY FIRST! MINIMIZING THE RISK OF MICRO EMBOLIZATION. Minimizing the risk of thrombotic effect LEGFLOW SAFEPAX technology utilizes the clinically important, nanocrystalline PTX particles. Even if PTX particles would broke free they would be too small to cause any embolic or thrombotic effect. When invisibility equals safety! 1. LEGFLOW PTX coating of 0.1µm appears translucent under light reflection. 2. Other DEB`s with unstable and brittle balloon coatings, consisting of large (visible) PTX particles, bear a risk for physicians and patients. 1 2 Microscopy of the LEGFLOW balloon surface showing no visible PTX particles Stable vs. unstable DEB PTX coating 05

7 More than patients successfully treated. NO DRUG COATING PITFALLS BUT ONLY HIGH PERFORMANCE. SUPERIOR PATIENT RESULTS. For the safest SFA & BTK revascularization therapy. 06 NO Paclitaxel debonding from the LEGFLOW balloon surface before or during catheter DEB manipulation. NO PTX breaks from a brittle coating during balloon inflation. The LEGFLOW PTX coating translates into a stable, smooth and elastic, balloon surface. NO thrombotic or embolic adverse effects caused by large PTX crystals of µm adhering to the vessel wall or caused by washed off PTX embolization. LEGFLOW s SAFEPAX technology is based on invisible nano crystalline PTX particles of only 0.1µm. NO risk of PTX contamination of the cathlab environment and personnel by detached and free PTX crystals as LEGFLOW provides a stable PTX balloon coating. NO PTX-associated adverse effect potential LEGFLOW s SAFEPAX coating controls the PTX particle dimension, distribution and release. NO hidden risk from the drug-release matrix: LEG- FLOW SAFEPAX consists of a novel and innovative Shellolic Ammonium salt composition. NO uncontrolled and unpredictable drug wash-off effect during balloon inflation and manipulation as LEGFLOW s moderate hydrophobic drug coating limits PTX wash-off and ensures sufficient reproducible drug delivery to the lesion site.

8 LEGFLOW RX/OTW PROVEN! OPTIMAL THERAPEUTIC DRUG- IN-TISSUE BIOAVAILABILITY RESULTING IN MAXIMAL CLINICAL EFFICACY. Paclitaxel in tissue concentration ng/mg Hours post dilatation * LEGFLOW reliable performance even in long and occluded lesions. Preliminary results of the randomized RAPID trial (LEGFLOW vs. POBA) reveal: LEGFLOW shows greatest effectiveness in reducing neo-intimal hyperplasia also in high-risk patients with challenging lesions. The randomized European multi-center RAPID clinical trial compares LEGFLOW Paclitaxel releasing PTA balloon dilatation catheter with stent placement vs. POBA with stent placement in the treatment of extraordinary-long superficial femoral artery (SFA) lesions of > 15 cm up to 25 cm length and a total occlusion rate of 80%. (Data on file at Cardionovum GmbH) LEGFLOW: No signs of vessel toxicity were found. No other safety concerns were noted in animals studied for up to 90 days.* A short-term balloon-to-vessel wall contact time of sec. is sufficient to inhibit SMC proliferation sustainably for up to 150 hours. Pre-clinical results confirm no noticeable embolization results similar to POBA. Pre-clinical study results confirm a most effective drug delivery into the vascular tissue, showing a sustained drug effect of up to 28 days. Cardionovum s DEB shows great effectiveness in neo-intimal growth reduction in diseased vessels. *Source: Report on pre-clinical studies performed at CV-PATH Institute (R. Virmani MD), Gaithersburg USA 07

9 LEGFLOW RX/OTW PRELIMINARY RAPID STUDY RESULTS. Extraordinary SFA lesion length >15-25cm at high 80% occlusion rate results in 95% patency and freedom of TLR. (Data on file at Cardionovum GmbH) More patient case reports and LEGFLOW presentations at LINC (Leipzig Interventional Course) + Veith Symposium New York, USA available on file at Cardionovum GmbH. Case 1: Pre-dilatation SFA lesion 15 cm long with a 12 cm occlusion. Severe calcification. 08 Case 1: Final result Single shot of LEGFLOW balloon inflated at 16 atm.

10 HIGH CLINICAL EFFICACY. OUTSTANDING CLINICAL PERFORMANCE AND EXCELLENT LONG-TERM PATIENT RESULTS. Case 2: Pre-dilatation Case 2: Final result SFA lesion 15 cm long with a 6 cm occlusion length. After LEGFLOW pre-dilatation optimal stenting result without residual stenosis. 09

11 THE WIDEST SELECTION OF BALLOON SIZES. LEGFLOW OTW Technical data Shaft material Polyamide Balloon material Polyamide Usable catheter length 135 cm or 80 cm (S) Max. recommended guidewire 0.035" Tip length 5.0 mm Rated burst pressure Introducer sheath size Paclitaxel coating S - ordersymbol 16 bar for Ø 4.0 Ø mm (length 60 mm) 14 bar for Ø mm (length > 60 mm) Ø mm (length 60 mm) 12 bar for Ø mm (length > 60 mm) Ø mm 5 F Ø 4.0 (length 60 mm) 6 F Ø 4.0 (length > 60 mm) 6 F Ø 5.0 to 6.0 mm 7 F Ø 7.0 to 10.0 mm 3.0µg/mm² 80 cm catheter length LEGFLOW OTW Order information Balloon length (mm) Balloon Ø (mm) OTW Catheter length 800mm (LS) or 1350mm (L) 4.0 mm 5.0 mm 6.0 mm 7.0 mm 8.0 mm 9.0 mm 10.0 mm 20 mm L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW 40 mm L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW 60 mm L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW 80 mm L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW mm L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW mm L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW mm L OTW LS OTW L OTW LS OTW L OTW LS OTW L OTW LS OTW

12 LEGFLOW RX/OTW Technical data OTW RX Shaft material Polyamide Stainless steel Balloon material Polyamide Polyamide Usable catheter length 150 cm 140 cm Max. recommended guidewire 0.014" Tip length 3.5 mm 3.5 mm Rated burst pressure 16 bar for Ø mm 14 bar for Ø mm 16 bar for Ø mm (length 40 mm) Ø 4.0 mm (length 20 mm) 14 bar for Ø mm (length > 40 mm) Ø 4.0 mm (length > 20 mm) Introducer sheath size 4 F 4 F Ø mm, 5 F Ø 4.0 mm Paclitaxel coating 3.0µg/mm² 3.0µg/mm² LEGFLOW RX/OTW Order information Balloon length (mm) Balloon Ø (mm) OTW Catheter length 1500 mm, RX Catheter length 1400 mm 2.0 mm 2.5 mm 3.0 mm 3.5 mm 4.0 mm 20 mm L RX L OTW L RX L OTW L RX L OTW L RX L OTW L RX L OTW 40 mm L RX L OTW L RX L OTW L RX L OTW L RX L OTW L RX 60 mm L RX L RX L RX L RX - 80 mm L RX L OTW L RX L OTW L RX L OTW L RX L OTW L RX 100 mm L RX L RX L RX L RX mm L RX L OTW L RX L OTW L RX L OTW L RX L OTW L RX 150 mm L RX L OTW L RX L OTW L RX L OTW L RX L OTW mm L RX L RX

Drug eluting balloon catheter

Drug eluting balloon catheter E x p a n d y o u r t h e r a p y o p t i o n s Drug eluting balloon catheter Only innovations based on scientific evidence create the level of confidence required to transfer optimal treatment methods

More information

SeQuent Please NEO. Clinically proven Polymer-free Drug Coated Balloon Catheter. Vascular Systems

SeQuent Please NEO. Clinically proven Polymer-free Drug Coated Balloon Catheter. Vascular Systems SeQuent Please NEO Clinically proven Polymer-free Drug Coated Balloon Catheter Vascular Systems 1 SeQuent Please NEO The Drug Coated Balloon with Clinical Evidence Polymer-Free Drug Delivery Moving forward

More information

BALLOON. 1. PTA Balloon Catheter 1.1 ALLUNGA Description Technical Data Materials used Compliance Chart

BALLOON. 1. PTA Balloon Catheter 1.1 ALLUNGA Description Technical Data Materials used Compliance Chart BALLOON 1. PTA Balloon Catheter 1.1 ALLUNGA 1.1.1. Description 1.1.2. Technical Data 1.1.3. Materials used 1.1.4. Compliance Chart 1.1.5. Graph 1.1.6. Side by Side Comparison amg International GmbH Löhnfeld

More information

ASAHI Neurovascular Guide Wire

ASAHI Neurovascular Guide Wire ASAHI Neurovascular Guide Wire AMK-DT244 Ver.1.00 / 11TS073 Legal manufacturer Consult instructions for use Do not use if package is damaged RX ONLY Caution: Federal (USA) Law restricts this device to

More information

Sprinter Family. balloon dilatation catheters. Sprinter Legend OTW Sprinter Legend RX Sprinter OTW

Sprinter Family. balloon dilatation catheters. Sprinter Legend OTW Sprinter Legend RX Sprinter OTW Sprinter Family balloon dilatation catheters Sprinter Legend OTW Sprinter Legend RX Sprinter OTW NC Sprinter RX Sprinter Family Medtronic offers you an extensive family of high-performing balloon dilatation

More information

The Art of. Flow Restoration. Raiden3. Non-Compliant PTCA Balloon

The Art of. Flow Restoration. Raiden3. Non-Compliant PTCA Balloon The Art of Flow Restoration Raiden3 Japan s Recognized PCI Technology Raiden3 For Both Everyday and Complex Cases Manufactured by Kaneka Corporation, one of Japan s leading providers of interventional

More information

PRODUCT CATALOGUE OF

PRODUCT CATALOGUE OF PRODUCT CATALOGUE OF INTERVENTIONAL CARDIOLOGY AND GENERAL MEDICAL DISPOSABLES Table of Contents INFLATION DEVICE... 4 GUIDE WIRE (PTFE)... 5 MANIFOLD... 6 PTCA Y Connector... 7 INTRODUCER SHEATH (Femoral/

More information

TrapLiner Catheter. Guide Extension Plus Wire Trapping

TrapLiner Catheter. Guide Extension Plus Wire Trapping TrapLiner Catheter Guide Extension Plus Wire Trapping 2-in-1 Device Guide Extension Catheter With Trapping Capabilities The TrapLiner Catheter is a rapid exchange guide extension catheter that combines

More information

INTERVENTIONAL CARDIOLOGY

INTERVENTIONAL CARDIOLOGY Y-Connector Newtech Y connector it is easy, fast and accurate single handed intra vascular device insertion. Perfect insertion device respecting the integrity of the coated surface with Combination of

More information

WE CARE ACCURATELY. ACCURA Medizintechnik GmbH Max-Planck-Straße Karben / Germany Tel:

WE CARE ACCURATELY. ACCURA Medizintechnik GmbH Max-Planck-Straße Karben / Germany Tel: WE CARE ACCURATELY ACCURA Medizintechnik GmbH Max-Planck-Straße 33-61184 Karben / Germany Tel: +49 6039 92010 Email: info@accuramed.de WELCOME TO ACCURA About ACCURA ACCURA Medizintechnik GmbH supplies

More information

Crosser CTO Recanalization Catheter High Frequency Mechanical Recanalization System

Crosser CTO Recanalization Catheter High Frequency Mechanical Recanalization System Crosser CTO Recanalization Catheter High Frequency Mechanical Recanalization System Instructions for Use Crosser Catheters 14P, 14S, 18, and S6 Warning! Carefully read all instructions prior to use. Observe

More information

Huber needle EZ Huber JetCan. Quality and Experience

Huber needle EZ Huber JetCan. Quality and Experience Quality and Experience Port systems TitaJet light II Contrast Jet Port Plus II Contrast DualPort Contrast TitaJet light Low Profile Contrast T-Port Contrast T-Port Low Profile Contrast TitaJet light Jet

More information

Bielefeld. Balloon Catheter The new treatment for chronic tube malfunction. Innovations by Spiggle & Theis

Bielefeld. Balloon Catheter The new treatment for chronic tube malfunction. Innovations by Spiggle & Theis C2 C3 C4 C1 Bielefeld Balloon Catheter The new treatment for chronic tube malfunction Innovations by Spiggle & Theis A new therapy concept for the treatment of chronic tube dysfunction Obstructive tube

More information

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides

NEXUS TKO. Specialty Neonatal/Pediatric. Safety Infusion Sets. Blood Reflux Protection 24/7! Anti-Reflux Technology Provides Specialty Neonatal/Pediatric Safety Infusion Sets Anti-Reflux Technology Provides Blood Reflux Protection 24/7! NEXUS TKO TECHNOLOGY THAT NEVER SLEEPS! Nexus TKO Neonatal Safety Catheter Nexus Tri-Seal

More information

Characterization and formulation of cocrystals

Characterization and formulation of cocrystals Characterization and formulation of cocrystals Cocrystals can deliver unique physical properties, but taking full advantage of these improved properties requires a new approach to cocrystal formulation

More information

CGuard MicroNet-Covered Embolic Prevention Stent System A Game Changer in Carotid Revascularization

CGuard MicroNet-Covered Embolic Prevention Stent System A Game Changer in Carotid Revascularization CARENET J Am Coll Cardiol 2015;66:B33 CGuard MicroNet-Covered Embolic Prevention Stent System A Game Changer in Carotid Revascularization Piotr Musialek, MD DPhil FESC Jagiellonian University Dept. of

More information

The Crosser CTO Recanalization Device (Bard

The Crosser CTO Recanalization Device (Bard Clinical dept headline Use of dept headline Crosser dept headline the CTO Recanalization Catheter dept deck DEPT YLINE n interventionist s perspective on the mechanism of action of the Crosser Catheter

More information

Never operate the Peripheral RotaLink Plus with the Rotablator

Never operate the Peripheral RotaLink Plus with the Rotablator 91119961-01 Rotablator Rotational Atherectomy System ONLY Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician. WARNING Contents supplied STERILE using an ethylene

More information

*

* Email: * cheekong@krdl.org.sg 336 X. Ma et al. procedures such as stent placement. Commercially available devices are based on the original mechanical design of the Gruentzig s device. Physicians have

More information

interventional neuroradiology products catalogue

interventional neuroradiology products catalogue interventional neuroradiology products catalogue about balt Globally supporting healthcare professionals with integrity for over 40 years by designing cutting-edge technology and manufacturing reliable

More information

Endotracheal Tubes - VentiSeal (High Volume Low Pressure)

Endotracheal Tubes - VentiSeal (High Volume Low Pressure) Endotracheal Tubes - VentiSeal (High Volume Low Pressure) VentiSeal reduces the risk of vocal cord injury and tracheal necrosis through an optimal volume cuff with ideal pressure distribution and effective

More information

BA SK ET A SSIST ED STONE EXTRACTION

BA SK ET A SSIST ED STONE EXTRACTION BA SK ET A SSIST ED STONE EXTRACTION OVERVIEW, PROCEDURAL TECHNIQUE AND CASE REPORT Presented by: Adam Elfant, MD Associate Head of Gastroenterology and Liver Disease Director of Therapeutic Endoscopy

More information

Nexus Detachable Coils

Nexus Detachable Coils Micro Therapeutics, Inc. Irvine, California 92618 USA Phone: +1 949-837-3700 Phone: +1 949-837-2044 www.1mti.com Authorized Representative in EU: MediMark Europe BP 2332 38033 Grenoble Cedex 2 France Nexus

More information

PERFORMANCE ZONES

PERFORMANCE ZONES A H E A D O F T H E C U R V E PERFORMANCE ZONES Each aspect of the graft is designed to optimize conformability and seal, with optimal radial force precisely where you need it. A PRIMARY SEAL AND FIXATION

More information

CoreValve in degenerated CoreValve 1st Re do CoreValve

CoreValve in degenerated CoreValve 1st Re do CoreValve TAVI summit 2012 Seoul, Sep 7, 2012 CoreValve in degenerated CoreValve 1st Re do CoreValve Eberhard Grube MD FACC, FSCAI Universitätsklinik ität ik Bonn, Medizinische i i Klinik ik und Poliklinik II, Bonn,

More information

Update on Acute Stroke Management

Update on Acute Stroke Management Update on Acute Stroke Management ACC Rockies, Banff March 2014 Brian Buck, MD MSc FRCPC Division of Neurology, Department of Medicine University of Alberta Disclosures None relevant to contents of presentation

More information

Emboli Protection Device

Emboli Protection Device General Information... 99 ANGIOGUARD RX components... 100 Ordering information... 101 Emboli Protection Device Emboli Protection Device Emboli Protection Device ANGIOGUARD RX ANGIOGUARD RX with its Rapid

More information

Bella Strong JOBST. OptiFit. New dimensions in effectiveness and comfort True confidence for patients with lymphedema and edema

Bella Strong JOBST. OptiFit. New dimensions in effectiveness and comfort True confidence for patients with lymphedema and edema JOBST Bella Strong Ready-to-Wear Armsleeve and Gauntlet Exceptional fit coverage OptiFit Improved quality of life New dimensions in effectiveness and comfort True confidence for patients with lymphedema

More information

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works:

The NAMIC Dream Kit. Single Operator Control. Reduce Contrast Waste. Less Force to Inject. Compensator * Manifold. How the Compensator Manifold Works: Dream Kit The NAMIC Dream Kit Single Operator Control. Reduce Contrast Waste. Less Force to Inject. For more than 40 years, NAMIC * Fluid Management products have been providing cardiologists, technicians

More information

Your Life. Your Adventure. Triton Family of Products

Your Life. Your Adventure. Triton Family of Products Your Life. Your Adventure. Triton Family of Products Ready for any challenge The search is over! Now your high-mobility patients can choose from a variety of superb options to fit their active lifestyles.

More information

A complete family of Pediatric Perfusion Systems

A complete family of Pediatric Perfusion Systems LEADING THE FIELD OF PEDIATRIC PERFUSION FOR OVER 25 YEARS A complete family of Pediatric Perfusion Systems Perfusion systems designed for the broadest range of pediatric patients Small, sensitive neonatal

More information

RADAR. User Manual EASYCLIK MODEL Vascular. Compression. Device.

RADAR. User Manual EASYCLIK MODEL Vascular. Compression. Device. RADAR EASYCLIK MODEL 4180 Vascular Compression Device User Manual www.compressar.com RADAR User Manual The single-use RadAR EasyClik Vascular Compression Device is indicated for use by medical professionals

More information

Pitfalls & Practical Tips

Pitfalls & Practical Tips Pitfalls & Practical Tips Pitfalls & Practical Tips Transducer Height and AO Pressure Equalization Guidewire Introducer Needles Guide Catheter (wedging, damping & side holes) PressureWire Drift Artifacts

More information

THE ULTIMATE COMBINATION DESIGNED FOR COMFORT + ENGINEERED FOR HEALING

THE ULTIMATE COMBINATION DESIGNED FOR COMFORT + ENGINEERED FOR HEALING THE ULTIMATE COMBINATION DESIGNED FOR COMFORT + ENGINEERED FOR HEALING THE ULTIMATE COMBINATION DESIGNED FOR COMFORT + ENGINEERED FOR HEALING AirSelect puts comfort, control and healing in the hands of

More information

THE ULTIMATE COMBINATION DESIGNED FOR COMFORT + ENGINEERED FOR HEALING

THE ULTIMATE COMBINATION DESIGNED FOR COMFORT + ENGINEERED FOR HEALING THE ULTIMATE COMBINATION DESIGNED FOR COMFORT + ENGINEERED FOR HEALING THE ULTIMATE COMBINATION DESIGNED FOR COMFORT + ENGINEERED FOR HEALING AirSelect puts comfort, control and healing in the hands of

More information

Elements for a Public Summary. Overview of disease epidemiology

Elements for a Public Summary. Overview of disease epidemiology VI.2 VI.2.1 Elements for a Public Summary Overview of disease epidemiology Benign prostatic hyperplasia (BPH) (an increase in size of the prostate that is not cancerous) is the most prevalent of all diseases

More information

Inspire rpap REVOLUTION FROM THE FIRST BREATH

Inspire rpap REVOLUTION FROM THE FIRST BREATH Inspire rpap TM REVOLUTION FROM THE FIRST BREATH The Inspire rpap The Inspire rpap is a revolutionary, non-invasive system for the initial stabilisation and resuscitation of infants. TM Its innovative,

More information

DESIGNING THE FUTURE OF TAVI

DESIGNING THE FUTURE OF TAVI DESIGNING THE FUTURE OF TAVI Meets the most critical needs in TAVI DESIGNED TO REDUCE PATIENT COMPLICATIONS Building on the proven benefits of the SAPIEN valve family, the SAPIEN 3 valve fulfills a promise

More information

Inspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to:

Inspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to: A H E A D O F T H E C U R V E C R A F T E D F O R P R E C I S I O N Inspired by the challenge to create a better solution for the thoracic aorta, RelayPlus was specifically designed to: Respect the thoracic

More information

Eustachian Tube Dysfunction Patient Questionnaire (ETDQ-7) Collection, Training and Utility

Eustachian Tube Dysfunction Patient Questionnaire (ETDQ-7) Collection, Training and Utility Eustachian Tube Dysfunction Patient Questionnaire (ETDQ-7) Collection, Training and Utility 2017 Acclarent, Inc. All rights reserved. 070561-170405 1 ETDQ-7: What is it? The ETDQ-7 is a disease-specific

More information

Consistency in Excellence.

Consistency in Excellence. Consistency in Excellence. The Round Gel Implant Family Cohesive I and Cohesive II Not for distribution in the U.S. All cohesive, all the time. More styles. More choices. Round Low wide base lower profile

More information

CLEAN ROOM Innovation applied to sterilizable devices

CLEAN ROOM Innovation applied to sterilizable devices CLEAN ROOM Innovation applied to sterilizable devices CLEAN ROOM Innovation applied to sterilizable devices A clean room is an environment subject to a contamination control, commonly used in the pharmaceutical,

More information

SCANNING ELECTRON MICROSCOPY ANALYSIS OF ELASTOMERIC O-RINGS AND SPRING SEALS FRACTURED DURING RAPID GAS DECOMPRESSION.

SCANNING ELECTRON MICROSCOPY ANALYSIS OF ELASTOMERIC O-RINGS AND SPRING SEALS FRACTURED DURING RAPID GAS DECOMPRESSION. SCANNING ELECTRON MICROSCOPY ANALYSIS OF ELASTOMERIC O-RINGS AND SPRING SEALS FRACTURED DURING RAPID GAS DECOMPRESSION. T. Mbwadzawo* and A. Hodzic Composite Systems Innovation Centre, Department of Mechanical

More information

The SAG type flat, rubber-steel, balance ropes

The SAG type flat, rubber-steel, balance ropes ROPES The SAG type flat, rubber-steel, balance ropes Application of the SAG ropes: The SAG type, flat, rubber-steel balance ropes, further on called the SAG ropes, are used for shaft transport at mines

More information

Flexible Containment Solutions Guide

Flexible Containment Solutions Guide Flexible Containment Solutions Guide FCSG 06 Contained Blending Flexible Enclosure Technology OVERVIEW Two methods of containing blenders have been demonstrated. Included here are the use of flexible enclosures

More information

(12) Patent Application Publication (10) Pub. No.: US 2008/ A1

(12) Patent Application Publication (10) Pub. No.: US 2008/ A1 (19) United States US 20080086110A1 (12) Patent Application Publication (10) Pub. No.: US 2008/0086110 A1 Galdonik et al. (43) Pub. Date: (54) EXTENDABLE DEVICE ON AN ASPIRATION CATHETER (76) Inventors:

More information

Lead Extraction Overview

Lead Extraction Overview Lead Extraction Overview Haitham Badran, MD, FESC Lecturer of Cardiology Ain Shams University DO WE NEED IT Indications for Extraction Infection (sepsis) Damaged leads (arrhythmias, venous trauma)

More information

MEROCEL HEMOX SPONGES

MEROCEL HEMOX SPONGES MEROCEL HEMOX SPONGES Now with oxidized cellulose, a clinically proven hemostatic agent G. H. I. A. B. C. D. E. F. Post-op sinus dressings Merocel hemox is constructed of high-density, micropore Merocel

More information

CS CANNULATION. Step-by-Step Guide. This guide contains recommendations as provided by Dr. Seth Worley, MD POWERED BY

CS CANNULATION. Step-by-Step Guide. This guide contains recommendations as provided by Dr. Seth Worley, MD POWERED BY This guide contains recommendations as provided by Dr. Seth Worley, MD POWERED BY 1 Advance dilator and CSG over 0.035 wire until dilator tip reaches the SVC. 2 Holding dilator stationary, advance CSG

More information

y 103 Fluid (12) Patent Application Publication (10) Pub. No.: US 2010/ A1 (19) United States Axi:X

y 103 Fluid (12) Patent Application Publication (10) Pub. No.: US 2010/ A1 (19) United States Axi:X (19) United States US 2010.0069900A1 (12) Patent Application Publication (10) Pub. No.: US 2010/0069900 A1 Shirley et al. (43) Pub. Date: Mar. 18, 2010 (54) DUAL BALLOON CATHETER ASSEMBLY (75) Inventors:

More information

PreludeSYNC. Radial Compression Device INSTRUCTIONS FOR USE

PreludeSYNC. Radial Compression Device INSTRUCTIONS FOR USE PreludeSYNC Radial Compression Device INSTRUCTIONS FOR USE PreludeSYNC Radial Compression Device English INSTRUCTIONS FOR USE PRODUCT DESCRIPTION The Prelude Sync Radial Compression Device is a sterile,

More information

A Trusted Path to Outstanding Outcomes

A Trusted Path to Outstanding Outcomes A Trusted Path to Outstanding Outcomes Deep skin resurfacing Courtesy of Suzanne L. Kilmer, MD Periorbital skin resurfacing Courtesy of J. Kevin Duplechain, MD Scar revision Courtesy of Jill S. Waibel,

More information

Natural Hair Transplant Medical Center, Inc Dove Street, Suite #250, Newport Beach, CA Phone

Natural Hair Transplant Medical Center, Inc Dove Street, Suite #250, Newport Beach, CA Phone Natural Hair Transplant Medical Center, Inc. 1000 Dove Street, Suite #250, Newport Beach, CA 92660 Phone-949-622-6969 Finasteride (PROPECIA ) Acknowledgement Finasteride is an oral medication, manufactured

More information

HEALIX ADVANCE TM KNOTLESS Anchor Fixation Strength vs. Arthrex SwiveLock & PushLock

HEALIX ADVANCE TM KNOTLESS Anchor Fixation Strength vs. Arthrex SwiveLock & PushLock HEALIX ADVANCE TM KNOTLESS Anchor Fixation Strength vs. Arthrex SwiveLock & PushLock Introduction The HEALIX ADVANCE KNOTLESS Anchors are the latest addition to the already successful HEALIX ADVANCE family

More information

BTL-6000 LYMPHASTIM BTL PRESSO-THERAPY SYSTEM FOR MEDICAL AND AESTHETIC PRACTICES

BTL-6000 LYMPHASTIM BTL PRESSO-THERAPY SYSTEM FOR MEDICAL AND AESTHETIC PRACTICES BTL-6000 LYMPHASTIM BTL PRESSO-THERAPY SYSTEM FOR MEDICAL AND AESTHETIC PRACTICES TECHNOLOGY The human lymphatic system is responsible for removing interstitial fluid from tissues. It absorbs and transports

More information

LFE OEM TCD - Thermal Conductivity Detector

LFE OEM TCD - Thermal Conductivity Detector LFE OEM TCD - Thermal Conductivity Detector Key features Quick response - T90 3 sec Extremely suppressed ranges High corrosion resistance High temperature capability up to 180 C Infallible containment

More information

ICE & TEE Monitoring in the Cath Lab TEE for ASD/PFO Closure

ICE & TEE Monitoring in the Cath Lab TEE for ASD/PFO Closure ICE & TEE Monitoring in the Cath Lab TEE for ASD/PFO Closure Craig E Fleishman, MD FACC FASE Director, Non-invaseive Cardiac Imaging The Heart Center at Arnold Palmer Hospital for Children, Orlando SCAI

More information

GUNDERSEN HEALTH SYSTEM ULTRASOUND DEPARTMENT POLICY AND PROCEDURE MANUAL

GUNDERSEN HEALTH SYSTEM ULTRASOUND DEPARTMENT POLICY AND PROCEDURE MANUAL GUNDERSEN HEALTH SYSTEM ULTRASOUND DEPARTMENT POLICY AND PROCEDURE MANUAL SUBJECT: Venous Insufficiency (Reflux) Ultrasound SECTION: Vascular Ultrasound ORIGINATOR: Kraig Schuster REVISED DATE: February

More information

of the Skin of Extremities

of the Skin of Extremities III. Oxygen Tension of Tissues by the Polarographic Method The Effect of Local Heat on the Oxygen Tension of the Skin of Extremities By ORVILLE HoRWITz, MI)., GEORGE PEIRCE, M.S., AND HUGH MONTGOMERY,

More information

INSPIRE Min.I. Redefining minimally invasive approach to perfusion. Expand your choices with INSPIRE Min.I.

INSPIRE Min.I. Redefining minimally invasive approach to perfusion. Expand your choices with INSPIRE Min.I. INSPIRE Min.I. TM Redefining minimally invasive approach to perfusion Expand your choices with INSPIRE Min.I. TM MINIMALLY INVASIVE PERFUSION versatile system configurations air system management low hemodilution

More information

MEDAP-MOBILE GAS SUPPLY

MEDAP-MOBILE GAS SUPPLY MEDAP-MOBILE GAS SUPPLY This document is intended to provide information to an international audience outside of the US. MOBILE GAS SUPPLY 3 MOBILE GAS SUPPLY FOR TRANSPORTATION AND WARD PRESSURE REGULATORS,

More information

ADVANCED CORE DECOMPRESSION SYSTEM X-REAM. Percutaneous Expandable Reamer PRO-DENSE. Core Decompression Procedure Kit SURGICAL TECHNIQUE

ADVANCED CORE DECOMPRESSION SYSTEM X-REAM. Percutaneous Expandable Reamer PRO-DENSE. Core Decompression Procedure Kit SURGICAL TECHNIQUE ADVANCED CORE DECOMPRESSION SYSTEM X-REAM Percutaneous Expandable Reamer PRO-DENSE Core Decompression Procedure Kit SURGICAL TECHNIQUE Advanced Core Decompression System Indications PRO-DENSE resultant

More information

DCS CPG: H02.01C TRANSCUTANEOUS PO2 (PtcO2) INTERPRETATION

DCS CPG: H02.01C TRANSCUTANEOUS PO2 (PtcO2) INTERPRETATION PtcO 2 Ordered te - 1 (A) Baseline reading performed at 15 minutes (Baseline with patient supine or semi-recumbent te 1: Indicators Lower extremity wound Diabetes History c/w risk for PVD Physical findings

More information

Instructions/Procedure for Use of the Speaking Valve

Instructions/Procedure for Use of the Speaking Valve Instructions/Procedure for Use of the Speaking Valve Notes on the use of the speaking valve for ventilator-dependent and non-ventilator dependent patients The speaking valve is a one-way valve that allows

More information

TubaVent The first causative therapy for tube dysfunction

TubaVent The first causative therapy for tube dysfunction The first causative therapy for tube dysfunction 2 New therapy concept in the treatment of chronic tube ventilation disorders Obstructive tube dysfunction is, a common chronic disorder, in which the usual

More information

Effective protection thanks to the latest technology

Effective protection thanks to the latest technology Effective protection thanks to the latest technology Fire protection is a top priority for any company, institution or public space. An accident of this type can irreparably affect the building, property

More information

Unity Sleeveless Elevated Vacuum System

Unity Sleeveless Elevated Vacuum System Unity Sleeveless Elevated Vacuum System 14/03/201 4 Form 8 Vacuum Advantages of vacuum suspension Very firm suspension providing excellent security and improved proprioception Elevated vacuum tends to

More information

(12) Patent Application Publication (10) Pub. No.: US 2003/ A1

(12) Patent Application Publication (10) Pub. No.: US 2003/ A1 (19) United States US 2003.0125721A1 (12) Patent Application Publication (10) Pub. No.: US 2003/0125721 A1 Yon et al. (43) Pub. Date: (54) METHOD AND DEVICE FOR PERFORMING COOLING OR CRYO-THERAPIES, FOR,

More information

For optimal strength and durability, we use a co-extrusion process of 3 different PVCs in the manufacturing of our pool cover slats.

For optimal strength and durability, we use a co-extrusion process of 3 different PVCs in the manufacturing of our pool cover slats. 2.1. Covrex Classic Covrex Classic Slats With ISO standard 1183 certification, Covrex pool covers have undergone an extensive series of tests including: Thermal coefficient of expansion testing; Elasticity

More information

AnastoClip GC Closure System

AnastoClip GC Closure System AnastoClip GC Closure System English Instructions for Use AnastoClip GC Closure System AnastoClip GC Closure System (Model Numbers 4008-06, 4008-07, 4008-08, 4010-01, 4010-02, 4010-03) IMPORTANT! This

More information

1C11 Terion K2. Confidence with every step. Information for Practitioners

1C11 Terion K2. Confidence with every step. Information for Practitioners 1C11 Terion K2 Confidence with every step Information for Practitioners Confidence with every step For prosthesis users who need a high level of stability With the 1C11 Terion K2, Ottobock has developed

More information

SIDE 16 Sidemount System User Manual

SIDE 16 Sidemount System User Manual SIDE 16 Sidemount System User Manual Version 1.1, April 15, 2014 Disclaimer This document is proprietary to Scubatech Sp. z o. o. ("Scubatech") and no ownership rights are hereby transferred. No part of

More information

GRYPHON BR Suture Anchor

GRYPHON BR Suture Anchor GRYPHON BR Suture Anchor Key Features & Benefits GRYPHON T GRYPHON P GRYPHON BR is the newest and smallest shoulder instability anchor in the DePuy Mitek portfolio. This suture anchor, despite being small

More information

Using the Pressure Products SafeSheath Worley Telescopic Lateral Vein Introducers to Optimize LV Lead Placement

Using the Pressure Products SafeSheath Worley Telescopic Lateral Vein Introducers to Optimize LV Lead Placement Using the Pressure Products Lateral Introducers to Optimize LV Lead Placement vein is acutely angulated The STD is a long standard 9F sheath (11F OD/9F ID) shaped to rest in the coronary sinus without

More information

Making Life Easier Easypump II

Making Life Easier Easypump II Making Life Easier Easypump II The elastomeric pump system for short- and long-term infusion therapy Elastomeric Infusion Systems Technical Guide Easypump II Disposable Elastomeric Infusion Pump System

More information

Diacan and Diacan S. The safe and gentle vascular access for dialysis

Diacan and Diacan S. The safe and gentle vascular access for dialysis Diacan and Diacan S The safe and gentle vascular access for dialysis Diacan Design meets function For patients & users Transparent, deformation-resistant Luer-Lock connection with optimised grip design

More information

The Peritrochanteric Space The Next Frontier in Hip Repair

The Peritrochanteric Space The Next Frontier in Hip Repair The Peritrochanteric Space The Next Frontier in Hip Repair The Peritrochanteric Space Explore the next frontier with technology-leading solutions Advance your techniques in arthroscopic hip repair with

More information

trufreeze Spray Kit CO CO Instructions for Use

trufreeze Spray Kit CO CO Instructions for Use CO8407030500 CO8407030501 trufreeze Spray Kit Instructions for Use CSA Medical, Inc. 91 Hartwell Avenue Lexington, MA 02421 USA 2015 CSA Medical, All Rights Reserved. CSA Medical and trufreeze are registered

More information

Injector system for implantation of 1stQ foldable intraocular lenses

Injector system for implantation of 1stQ foldable intraocular lenses Instruction For Use 1st Inject Instrument Injector system for implantation of 1stQ foldable intraocular lenses The IFU is available electronically on our website: www.1stq.eu Content: The package contains

More information

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM

DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DIAPHRAGM PUMPS WITH KNF STABILIZATION SYSTEM DATA SHEET E 037 N 940.5 APE as AC version in IP 54 N 940.5 APE-W with multi-voltage power supply input (As an option adjustable with potentiometer or by external

More information

Fiberoptic Intubation Made Easi(er) Know Your Scope. Indications. Christine Whitten MD Department of Anesthesia Kaiser Permanente San Diego

Fiberoptic Intubation Made Easi(er) Know Your Scope. Indications. Christine Whitten MD Department of Anesthesia Kaiser Permanente San Diego Fiberoptic Intubation Made Easi(er) Christine Whitten MD Department of Anesthesia Kaiser Permanente San Diego Know Your Scope Check before use: if it won t work during check out, it won t work during intubation

More information

STAP. Differential pressure controller DN 15-50

STAP. Differential pressure controller DN 15-50 Differential pressure controller 15-50 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE is a high-performing differential pressure controller that keeps the

More information

AUTOMATIC BOLLARDS APPLICATIONS. 4 Commercial premises 4Education 4Pedestrian areas 4 City centres

AUTOMATIC BOLLARDS APPLICATIONS. 4 Commercial premises 4Education 4Pedestrian areas 4 City centres BOLLARDS Jacksons provide a host of bollards to suit all of your needs. Each type of bollard has its own unique advantages from our static security bollards to automatic security bollards for your home

More information

MaxIMuM PRECISION. V-Posil. IN up TO 30% less CHaIR TIME. OPTIMal WORKING TIME SHORT SETTING TIME TIME OPTIMIZED HIGH PRECISION VPS IMPRESSION SYSTEM

MaxIMuM PRECISION. V-Posil. IN up TO 30% less CHaIR TIME. OPTIMal WORKING TIME SHORT SETTING TIME TIME OPTIMIZED HIGH PRECISION VPS IMPRESSION SYSTEM IN up TO 30% less CHaIR TIME OPTIMal WORKING TIME SHORT SETTING TIME TIME OPTIMIZED HIGH PRECISION VPS IMPRESSION SYSTEM MaxIMuM PRECISION FaSTER and HIGHER PRECISION with MORE FlExIbIlITY Today there

More information

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders.

Specialty gases in small cylinders. Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders. Specialty gases in small cylinders Combine flexibility and safety with lightweight portability. Specialty gases in small cylinders. 02 Specialty gases in small cylinders Our specialty gases guarantee precision.

More information

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New

Calibrated or locked versions available. TREATMENT > Series MD regulators GENERAL DATA. New > Series MD regulators Series MD pressure regulators New Ports with interchangeable cartridges: threaded (1/8, 1/4, /8) or integrated with super-rapid fitting for tube with Ø 6, 8 and 10 mm Versions: single,

More information

2) an acute situation in which hypoxemia is suspected.

2) an acute situation in which hypoxemia is suspected. I. Subject: Oxygen Therapy II. Policy: Oxygen therapy shall be initiated upon a physician's order by health care professionals trained in the set-up and principles of safe oxygen administration. Oxygen

More information

UNCLASSIFIED. RDT&E BUDGET ITEM JUSTIFICATION SHEET (R-2 Exhibit) COST (Dollars in Millions) FY03 FY04 FY05 FY06 FY07 FY08 FY09 Cost to Complete

UNCLASSIFIED. RDT&E BUDGET ITEM JUSTIFICATION SHEET (R-2 Exhibit) COST (Dollars in Millions) FY03 FY04 FY05 FY06 FY07 FY08 FY09 Cost to Complete RDT&E BUDGET ITEM JUSTIFICATION SHEET (R-2 Exhibit) DATE FEBRUARY 2004 APPROPRIATION / BUDGET ACTIVITY RDT&E, DEFENSE-WIDE / 2 R-1 ITEM NOMENCLATURE / PROJECT NO. PE 1160407BB Special Operations Forces

More information

Instruments. Like gold to your eyes, difference in your hands!

Instruments. Like gold to your eyes, difference in your hands! Instruments Like gold to your eyes, difference in your hands! 2 3 Like gold to your eyes, difference in your hands! PANDOR is a new black&gold range of "surface engineered" surgical instruments combining

More information

Our Company. Sail with us into calm waters! -

Our Company. Sail with us into calm waters! - Rudder Systems Our Company The company MM-Offshore GmbH is one of the major designing and producing ship s equipment supplier in the international shipbuilding market. With our experience of more than

More information

Deep groove ball bearings L12DDU. Polyolefin is used for packaging food in supermarkets, replacing dioxin-generating vinyl chloride.

Deep groove ball bearings L12DDU. Polyolefin is used for packaging food in supermarkets, replacing dioxin-generating vinyl chloride. Bearings Environmentally friendly Bearings offer high performance in water- and dust-contaminated environments. Enhanced strength makes these ever-evolving bearings ideal for high-speed. Bearings 22311L12CAM

More information

Physiological Considerations for Compression Bandaging

Physiological Considerations for Compression Bandaging Physiological Considerations for Compression Bandaging Harvey N. Mayrovitz, Ph.D. Professor of Physiology College of Medical Sciences Nova Southeastern University mayrovit@nsu.nova.edu At the completion

More information

Case Iatrogenic venous air embolism

Case Iatrogenic venous air embolism Case 10857 Iatrogenic venous air embolism La Pietra P, Sommario M, Marchini N, Venturi P Ospedale Bentivoglio, Asl Bologna, Dipartimento servizi; Via Marconi 40121 Bentivoglio, Italy; Email:plapietra@tin.it

More information

APRV: Moving beyond ARDSnet

APRV: Moving beyond ARDSnet APRV: Moving beyond ARDSnet Matthew Lissauer, MD Associate Professor of Surgery Medical Director, Surgical Critical Care Rutgers, The State University of New Jersey What is APRV? APRV is different from

More information

Our Company. Sail with us into calm waters! -

Our Company. Sail with us into calm waters! - Rudder Systems Our Company The company MM-Offshore GmbH is one of the major designing and producing ship s equipment supplier in the international shipbuilding market. With our experience of more than

More information

GAS SYSTEM HYDRA GS. The gas installation system that sets new standards. Witzenmann GmbH

GAS SYSTEM HYDRA GS. The gas installation system that sets new standards. Witzenmann GmbH GAS SYSTEM The gas installation system that sets new standards. Witzenmann GmbH Östliche Karl-Friedrich-Str. 134 75175 Pforzheim, Germany Phone +49 7231 581-0 Fax +49 7231 581-820 wi@witzenmann.com www.witzenmann.com

More information

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management. AT4 Tourniquet System. Introduction.

Tourniquet System. Ideal for single or bi-lateral orthopaedic surgery and pain management. AT4 Tourniquet System. Introduction. Tourniquet System Ideal for single or bi-lateral orthopaedic surgery and pain management Innovative technology practically applied Renowned for innovation and high quality, Anetic Aid listens to customers

More information

deltaflowc deltaflowc Venturi or Probe

deltaflowc deltaflowc Venturi or Probe deltaflowc Mass Flowmeter for Gases - Multivariable with ultra fast dp, p and T-sensors - Compact, accurate and user-friendly - Ideal for OEMs deltaflowc Venturi or Probe Precise mass flow metering deltaflowc