POWERTRAIN CONTROL MODULE PIN IDENTIFICATION & VOLTAGE CHARTS > AXIOM 3.5L, PASSPORT, RODEO & RODEO SPORT 3.2L

Size: px
Start display at page:

Download "POWERTRAIN CONTROL MODULE PIN IDENTIFICATION & VOLTAGE CHARTS > AXIOM 3.5L, PASSPORT, RODEO & RODEO SPORT 3.2L"

Transcription

1 ENGINE CONTROLS - PIN VOLTAGE CHARTS INTRODUCTION 2002 Isuzu Axiom 3.5L Eng Base Pin voltage (value) charts are used for diagnosing intermittent symptoms and faults that are unable to be resolved during self-diagnostics. Pin voltage tests ensure Powertrain Control Module (PCM) is receiving and transmitting proper voltage and other signals. Before performing tests, ensure engine mechanical condition has been thoroughly inspected and self-diagnostics have been attempted. Available Technical Service Bulletins (TSBs) may also be helpful in correcting a hard to diagnose problem. POWERTRAIN CONTROL MODULE PIN IDENTIFICATION & VOLTAGE CHARTS CAUTION: When battery is disconnected, vehicle computer and memory systems may lose memory data. Driveability problems may exist until computer systems have completed a relearn cycle. See COMPUTER RELEARN PROCEDURES article in GENERAL INFORMATION before disconnecting battery. NOTE: Unless stated otherwise in testing procedures, preform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance. Carefully backprobe PCM harness connector using Wiring Harness Tester Set (J35616-A/BT-8637) to avoid connector damage. Voltage readings may vary slightly due to battery condition or charging rate. NOTE: PCM may also be referred to as ECM. Generator may also be referred to as alternator. POWERTRAIN CONTROL MODULE PIN IDENTIFICATION & VOLTAGE CHARTS > AXIOM 3.5L, PASSPORT, RODEO & RODEO SPORT 3.2L NOTE: For Axiom, Passport and Rodeo PCM harness connector and terminal identification, see Fig 1 -Fig /17

2 Fig 1: Identifying Blue Powertrain Control Module Harness Connector E-34 Terminals & Pins No (Axiom, Passport, Rodeo & Rodeo Sport 3.2L) 2/17

3 Fig 2: Identifying Blue Powertrain Control Module Harness Connector E-34 Terminals & Pins No (Axiom, Passport, Rodeo & Rodeo Sport 3.2L) 3/17

4 Fig 3: Identifying Blue Powertrain Control Module Harness Connector E-34 Terminals & Pins No (Axiom, Passport, Rodeo & Rodeo Sport 3.2L) 4/17

5 Fig 4: Identifying Blue Powertrain Control Module Harness Connector E-34 Terminals & Pins No (Axiom, Passport, Rodeo & Rodeo Sport 3.2L) 5/17

6 Fig 5: Identifying Red Powertrain Control Module Harness Connector E-35 Terminals & Pins No (Axiom, Passport, Rodeo & Rodeo Sport 3.2L) 6/17

7 Fig 6: Identifying Red Powertrain Control Module Harness Connector E-35 Terminals & Pins No (Axiom, Passport, Rodeo & Rodeo Sport 3.2L) 7/17

8 Fig 7: Identifying Red Powertrain Control Module Harness Connector E-35 Terminals & Pins No (Axiom, Passport, Rodeo & Rodeo Sport 3.2L) 8/17

9 Fig 8: Identifying Red Powertrain Control Module Harness Connector E-35 Terminals & Pins No (Axiom, Passport, Rodeo & Rodeo Sport 3.2L) TYPICAL SCAN TOOL VALUES > TEST CONDITIONS NOTE: While limited diagnostic information is 9/17

10 available, vehicle manufacturer does not support diagnostic information using aftermarket scan tools. To properly diagnose vehicle, it is recommended to use TECH 2 scan tool. Ensure that scan tool is functioning properly. A scan tool that displays faulty data will lead to improper diagnosis, and unnecessary replacement of parts. Use typical scan tool values only after On-Board-II Diagnostic (OBD-II) system check has been performed, ensure no DTCs were stored in memory and it has been determined that on-board diagnostics are functioning properly. Typical scan tool values represent values found on a normally running vehicle, and can aid in diagnosing vehicle with poor engine performance. If after performing OBD-II system check, verify scan tool data. If no problem is found with scan tool data and symptom persists repair by symptom. See TROUBLE SHOOTING - NO CODES article. The following conditions must be met before testing: Engine at normal operating temperature. Engine at idle (closed throttle). Transmission in Park or Neutral. Accessories off. A/C system off. Closed-loop operation. TYPICAL SCAN TOOL VALUES > SCAN TOOL DATA VALUES > AXIOM 3.5L 10/17

11 Fig 1: Typical Scan Tool Values (Axiom 3.5L - 1 Of 7) 11/17

12 Fig 2: Typical Scan Tool Values (Axiom 3.5L - 2 Of 7) 12/17

13 Fig 3: Typical Scan Tool Values (Axiom 3.5L - 3 Of 7) 13/17

14 Fig 4: Typical Scan Tool Values (Axiom 3.5L - 4 Of 7) 14/17

15 Fig 5: Typical Scan Tool Values (Axiom 3.5L - 5 Of 7) 15/17

16 Fig 6: Typical Scan Tool Values (Axiom 3.5L - 6 Of 7) 16/17

17 Fig 7: Typical Scan Tool Values (Axiom 3.5L - 7 Of 7) 17/17

Evaporative Emissions (EVAP) system, checking

Evaporative Emissions (EVAP) system, checking Page 1 of 12 24-136 Evaporative Emissions (EVAP) system, checking CAUTION! Whenever carrying out work on the fuel supply and/or fuel injection systems, read and carefully follow the Cautions, Warnings,

More information

https://w05.dealerconnect.chrysler.com/service/mds2002/serviceinfo/en_us/81689ac0.htm... *ACTUATOR CIRCUIT TEST DIAGNOSTICS (DUAL-ZONE)

https://w05.dealerconnect.chrysler.com/service/mds2002/serviceinfo/en_us/81689ac0.htm... *ACTUATOR CIRCUIT TEST DIAGNOSTICS (DUAL-ZONE) Page 1 of 14 *ACTUATOR CIRCUIT TEST DIAGNOSTICS (DUAL-ZONE) Page 2 of 14 For a complete wiring diagram Refer to Section 8W. Theory of Operation By running the Actuator Circuit Test, the A/C Heater Control

More information

Technical Service BULLETIN

Technical Service BULLETIN Technical Service BULLETIN November 12, 2004 Title: Models: 03 04 4Runner & Tundra, 04 Camry, Highlander, Sienna & Solara EG048-04 ENGINE TSB REVISION NOTICE: January 6, 2005: A change has been made to

More information

HOW TO PROCEED WITH TROUBLESHOOTING

HOW TO PROCEED WITH TROUBLESHOOTING 01 24 INTRODUCTI HOW TO PROCEED WITH TROUBLESHOOTING Carry out troubleshooting in accordance with the procedure on the following page. Here, only the basic procedure is shown. Details are provided in the

More information

DTC P0441 Evaporative Emission Control System Incorrect. DTC P0446 Evaporative Emission Control System Vent Control Malfunction

DTC P0441 Evaporative Emission Control System Incorrect. DTC P0446 Evaporative Emission Control System Vent Control Malfunction DI90 IN (2RZF, 3RZF) DI17A04 DTC P0441 vaporative mission Control System Incorrect Purge Flow DTC P0446 vaporative mission Control System Vent Control Malfunction CIRCUIT DSCRIPTI The vapor pressure sensor

More information

Procedure Troubleshooting the Interconnect Cables

Procedure Troubleshooting the Interconnect Cables Procedure 6.1 - Troubleshooting the Interconnect Cables Troubleshooting the upper interconnect cable 1. Remove the display housing per Procedure 7.13. Disconnect the upper interconnect cable from the upper

More information

Gas Network Craftsperson

Gas Network Craftsperson Gas Network Craftsperson Unit EIAU016 Carrying out Fault Diagnosis on Electrical Equipment and Circuits This assessment specification has been developed as part of the network maintenance craftsperson

More information

Diagnostic Report. Confirmed trouble codes have been detected Number of incomplete tests exceeds the maximum number allowed

Diagnostic Report. Confirmed trouble codes have been detected Number of incomplete tests exceeds the maximum number allowed Diagnostic Report Created by OBDLink - OBD Solutions www.obdsoftware.net Date: 9/6/2017 9:06:33 PM VIN: t Available Monitor Status Report Name Continuous Available Complete Misfire Fuel System Components

More information

LENNOX SLP98UHV DIAGNOSTIC CODES

LENNOX SLP98UHV DIAGNOSTIC CODES Code Status of Equipment Action required to clear and recover - Idle mode (Decimal blinks at 1 Hertz -- 0.5 second ON, 0.5 second OFF) A Cubic feet per minute (cfm) setting for indoor blower (1 second

More information

GDC 2 Wire Control System

GDC 2 Wire Control System Golf Irrigation GDC 2 Wire Control System GDC 2 Wire System, Best Practices GDC Best Practices Wiring GDC Best Practices Not So Best Wiring GDC Best Practices Not So Best Wiring GDC Best Practices Not

More information

Additions, Revisions, or Updates

Additions, Revisions, or Updates 1 3 01-12 SUBJECT DATE SPN 4334/FMI 2, 3, 4, 7 and SPN 4375/FMI 6 February 2012 Additions, Revisions, or Updates Publication Number / Title Platform Section Title Change SPN 4334/FMI 2 DDC-SVC-MAN-0084

More information

Driveability: What is normal?

Driveability: What is normal? Southern Illinois University Carbondale OpenSIUC Presentations Department of Automotive Technology Fall 2009 Driveability: What is normal? Matt Dixon Southern Illinois University Carbondale, dixonm@siu.edu

More information

A u t o m o t i v e E l e c t r i c a l S y s t e m s ( 1 2 A )

A u t o m o t i v e E l e c t r i c a l S y s t e m s ( 1 2 A ) 8 7 0 0 A u t o m o t i v e E l e c t r i c a l S y s t e m s ( 1 2 A ) 40S/40E/40M An Automotive Technology Course 8 7 0 0 : A u t o m o t i v e E l e c t r i c a l S y s t e m s ( 1 2 A ) 4 0 S / 4

More information

Additions, Revisions, or Updates

Additions, Revisions, or Updates 1 2 06-11 SUBJECT DATE SPN 4375/FMI 6 DEF Pump Supply Current High February 2011 Additions, Revisions, or Updates Publication Number / Title Platform Section Title Change DDC-SVC-MAN-0084 EPA10 DD SPN

More information

DTC P0442 EVAPORATIVE EMISSION CONTROL SYSTEM LEAK DETECTED (SMALL LEAK) DTC P0455 EVAPORATIVE EMISSION CONTROL SYSTEM LEAK DETECTED (GROSS LEAK)

DTC P0442 EVAPORATIVE EMISSION CONTROL SYSTEM LEAK DETECTED (SMALL LEAK) DTC P0455 EVAPORATIVE EMISSION CONTROL SYSTEM LEAK DETECTED (GROSS LEAK) DTC P0442 EVAPORATIVE EMISSION CONTROL SYSTEM LEAK DETECTED (SMALL LEAK) 05563 05MOQ01 DTC P0455 EVAPORATIVE EMISSION CONTROL SYSTEM LEAK DETECTED (GROSS LEAK) DTC P0456 EVAPORATIVE EMISSION CONTROL SYSTEM

More information

Service Installation: 48 V Power Supply September 27, 2018 SI Written by BTA

Service Installation: 48 V Power Supply September 27, 2018 SI Written by BTA Service Installation: 48 V Power Supply September 27, 2018 SI-92718 Written by BTA 48 Volt Power Supply Installation Guide PROCEDURE: Parts Needed: 48V Power Supply Kit Tools Needed: Standard screwdriver,

More information

Some Furnace Questions I received an from a podcast listener with some furnace related questions. Based on the nature of the questions I figured

Some Furnace Questions I received an  from a podcast listener with some furnace related questions. Based on the nature of the questions I figured Some Furnace Questions I received an email from a podcast listener with some furnace related questions. Based on the nature of the questions I figured it would be better to ask an experienced furnace tech.

More information

SAAB EVAP Update & ORVR Workbook 1

SAAB EVAP Update & ORVR Workbook 1 SAAB EVAP Update & ORVR Workbook 1 Instructions for this Interactive Training course: 1. Read the objectives of this self study course on the next page. This will give you a good idea of what you can expect

More information

Document How to Set Single Stage Press Pressures

Document How to Set Single Stage Press Pressures Published Document Number: IIFUUC01 Specified Date: 20040701 As-of Date: 20040701 Access Date: 20040701 Depth: detail Applicability: not used Language Code: ENG01, Purpose: publication, Format: 1colA Document

More information

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES 1990 Nissan 240SX 1983-90 AIR CONDITIONING & HEAT General Servicing Diagnostic Procedures All Import Makes & Models Diagnosis is an important first step in A/C

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

AE R1 February 2015

AE R1 February 2015 February 2015 CoreSense Diagnostics for Copeland Scroll UltraTech Air Conditioning Compressors TABLE OF CONTENTS Safety Safety Instructions... 2 Safety Icon Explanation... 2 Instructions Pertaining to

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

12V MINI AIR COMPRESSOR

12V MINI AIR COMPRESSOR 12V MINI AIR COMPRESSOR STOCK No.65958 PART No.DA12/250A INSTRUCTIONS IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS TOOL. 08/2001 GENERAL INFORMATION

More information

APPS-160 Gen 2 User Manual

APPS-160 Gen 2 User Manual APPS-160 Gen 2 User Manual Applicable Products: PN 11914406 - APPS-160 10 to 50 PSIG operating pressure PN 11918618 - APPS-160 40 to 85 PSIG operating pressure Rev 9/16/2004 Chart Ind. www-chart-ind.com

More information

Stand-Alone Bubble Detection System

Stand-Alone Bubble Detection System Instruction Sheet P/N Stand-Alone Bubble Detection System 1. Introduction The Bubble Detection system is designed to detect air-bubble induced gaps in a bead of material as it is being dispensed. When

More information

12V Mini Air Compressor

12V Mini Air Compressor INSTRUCTIONS FOR 12V Mini Air Compressor Stock No.80999 Part No.DA12/250B IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY TO ENSURE THE SAFE AND EFFECTIVE USE OF THIS PRODUCT. GENERAL INFORMATION This

More information

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES

BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP SERIES BRILLIANT WONDERS LED BUBBLERS INSTALLATION INSTRUCTIONS & PRODUCT MANUAL CMP 25503 SERIES TABLE OF CONTENTS A. PRODUCT OVERVIEW A.1 SPECIFICATIONS A. PRODUCT OVERVIEW... 3 A.1 Specifications A.2 Packing

More information

TECH TIPS TZ34/20 & TZ50/30. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench.

TECH TIPS TZ34/20 & TZ50/30. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench. Service Call: Machine will not automatically level. Tools Needed: Multi Meter Jumper wire 7/16 Combination wrench Model: TZ34/20 & TZ50/30 Tech Tips Safety Rules Danger Failure to obey the instructions

More information

MARATHON SENSORS INC. TROUBLESHOOTING A CARBON PROBE

MARATHON SENSORS INC. TROUBLESHOOTING A CARBON PROBE When there is a problem making consistent product in a carborizing furnace you must consider all the possibilities before replacing the oxygen sensor. In many cases using the sensor and the control instrument

More information

A/C SYSTEM DIAGNOSIS

A/C SYSTEM DIAGNOSIS A/C SYSTEM DIAGNOSIS 1988 Jeep Cherokee 1988 AIR CONDITIONING & HEAT A/C General Servicing Diagnostic Procedures Jeep; All Models DIAGNOSTIC PROCEDURES Diagnosis is an important first step in A/C system

More information

Sedan Range. Evaporative Loss System Check Clarified Procedure

Sedan Range. Evaporative Loss System Check Clarified Procedure SERVICE Sedan Range DATE 3/98 TECHNICAL BULLETIN Evaporative Loss System Check Clarified Procedure 05.1-29 MODEL 1996-97 MY Sedan (4.0L) Range VIN 772231-812255 SWB 776271-812255 LWB ISSUE: A mandatory

More information

Technical Service Bulletin

Technical Service Bulletin Technical Service Bulletin IMPORTANT GROUP DATE NUMBER CAMPAIGN 15-01-023 MAY 2015 F UE L FEED TUBE REPLA C EMENT (SERVICE CAMPAIGN 937) MODEL(S) VELOSTER (FS) *** Retail Vehicles Only *** Dealers must

More information

Wildcat LB Winch Kit. Operator s Manual Installation Instructions Replacement Parts List. With Wireless Control System.

Wildcat LB Winch Kit. Operator s Manual Installation Instructions Replacement Parts List. With Wireless Control System. p/n 2259-560 Wildcat 4000 LB Winch Kit With Wireless Control System Operator s Manual Installation Instructions Replacement Parts List 2012 Arctic Cat Inc. Trademarks of Arctic Cat Inc. Thief River Falls,

More information

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE

WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE PACIFIC LIQUID & AIR SYSTEMS WPB 5 / 7 / 10 INSTALLATION, OPERATION, & MAINTENANCE IN THE BEGINNING Before installing or operating this system, familiarize yourself with these instructions. You should

More information

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL NUMBER: P PORTABLE COMPRESSOR MODEL NUMBER: 30033-300P PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product.

More information

frequently asked questions

frequently asked questions Hydra Pilot Fault Codes What do the fault codes for the Hydra Pilot mean? Fault Cause FAULT 100 FAULT 101 FAULT 102 FAULT 103 FAULT 104 FAULT 105 FAULT 106 FAULT 108 FAULT 109 FAULT 110 FAULT 111 FAULT

More information

ES18 Security Theory/Regulations Answer Schedule

ES18 Security Theory/Regulations Answer Schedule ES18 Security Theory/Regulations Answer Schedule Notes:1. means that the preceding statement/answer earns 1 mark. 2. This schedule sets out the expected answers to the examination questions. The marker

More information

Instruction and Practice Manual

Instruction and Practice Manual Instruction and Practice Manual Axiom Sports Manufacturing A Division of Fitec International 3525 Ridge Meadow Parkway Memphis, TN 38175 (901) 366-9144 www.axiomsports.com 1 Thank you for purchasing the

More information

Victoreen B. Operators Manual. Image Intensifier Ion Chamber

Victoreen B. Operators Manual. Image Intensifier Ion Chamber Victoreen 6000-530B Image Intensifier Ion Chamber Operators Manual March 2005 Manual No 6000-530B-1 Rev. 4 2004, 2005 Fluke Corporation, All rights reserved. All product names are trademarks of their respective

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

Manual Leveling Control Installation/Operation

Manual Leveling Control Installation/Operation ELECTROMECHANICAL TRIM TAB SYSTEMS Manual Leveling Control Installation/Operation Linear Devices Corporation dba Lectrotab 11126 Air Park Road, Suite G Ashland, VA 23005 www.lectrotab.com Phone: 804-368-8428

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17

Operation Manual. O2 Quickstick. Oxygen Analyzer 08.17 Operation Manual O2 Quickstick Oxygen Analyzer 08.17 If you have any questions on this equipment please contact Technical Support at: Nuvair 1600 Beacon Place Oxnard, CA 93033 Phone: 805-815-4044 FAX:

More information

SEMEMI SQA Unit Code H2AP 04 Carrying out fault location on electrical equipment and circuits

SEMEMI SQA Unit Code H2AP 04 Carrying out fault location on electrical equipment and circuits Carrying out fault location on electrical equipment and circuits Overview This unit identifies the competences you need to locate faults on electrical equipment and circuits, in accordance with approved

More information

T EK-SUB 4800C 19 mm Submersible Level Transmitter

T EK-SUB 4800C 19 mm Submersible Level Transmitter Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2

More information

PS Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions

PS Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions PS07569 201412 Plasma 375 Plasma Cutter Kit Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation

More information

! Warning, refer to accompanying documents.

! Warning, refer to accompanying documents. About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

SAFETY IN THE SHOP MPO NOA Reference:

SAFETY IN THE SHOP MPO NOA Reference: MPO-0100 SAFETY IN THE SHOP NOA Reference: The material covered satisfies in whole or in part, the requirements of the National Occupational Analysis for the Automotive Service Technician task 1. Description:

More information

Troubleshooting Guide How to Properly Diagnose a Water Valve: Single, Triple, and Quadruple Solenoid Valves

Troubleshooting Guide How to Properly Diagnose a Water Valve: Single, Triple, and Quadruple Solenoid Valves How to Properly Diagse a Water Valve: Single, Triple, and Quadruple Soleid Valves When water is t supplied to the water dispenser or ice maker, the water valve is frequently suspected to be defective.

More information

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO 400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

BUTTERFLY VALVES Series 800

BUTTERFLY VALVES Series 800 BUTTERFLY VALVES Series 800 WARNING Before proceeding read ALL instructions and become familiar with the equipment and associated drawings. Follow ALL applicable safety regulations and codes for pressurized

More information

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations

C&G Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations C&G 2395-01 Level 3 Award in the Periodic Inspection, Testing and Certification of Electrical Installations Test instruments and recommended testing sequence 1 Outcomes of this Session describe the different

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

GAS FUEL VALVE FORM AGV5 OM 8-03

GAS FUEL VALVE FORM AGV5 OM 8-03 ALTRONIC AGV5 OPERATING MANUAL GAS FUEL VALVE FORM AGV5 OM 8-03 WARNING: DEVIATION FROM THESE INSTALLATION INSTRUCTIONS MAY LEAD TO IMPROPER ENGINE OPERATION WHICH COULD CAUSE PERSONAL INJURY TO OPERATORS

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option

MANUAL DIRECT PURGE OPTION. UNION Instruments GmbH CWD2005 PLUS. General information, safety standards and regulations for direct purge option MANUAL DIRECT PURGE OPTION UNION Instruments GmbH CWD2005 PLUS General information, safety standards and regulations for direct purge option Version: V1.00 Stand: 24.03.2010 Union Instruments GmbH Zeppelinstr.

More information

TOYOTA TACOMA 2005 TOW HITCH Preparation. Part Number: PT

TOYOTA TACOMA 2005 TOW HITCH Preparation. Part Number: PT Preparation Part Number: PT791 04050 Kit Contents 1 1 Hitch Center Section 2 1 LH Frame bracket 1 RH Frame Bracket 4 2 Auxiliary Bracket Hardware Bag Contents 1 6 Hex Head Bolt, M12 x 1.2 (black) 2 6 Nut,

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

Aqua Control, Inc. 60Hz. BOTTOM CIRCULATOR INSTRUCTION MANUAL TABLE OF CONTENTS

Aqua Control, Inc. 60Hz. BOTTOM CIRCULATOR INSTRUCTION MANUAL TABLE OF CONTENTS Aqua Control, Inc. 60Hz. BOTTOM CIRCULATOR INSTRUCTION MANUAL TABLE OF CONTENTS PAGE PAGE Safety 1 Anchoring Anchoring Instructions 6 Installation / Launching Floating of the Bottom Circulator 2 Sinking

More information

unconventional-airsoft.com

unconventional-airsoft.com unconventional-airsoft.com Congratulations on your new digital fire control computer! This unit will change the way you use and look at your electric gun. With this short document, you will know all you

More information

Installation Instructions Air Compressor Part # 2780, 2781

Installation Instructions Air Compressor Part # 2780, 2781 Note: It is essential that the operator of this product read and understand the contents of this manual before installing and using this product. Parts Included Qty Parts Included Qty Compressor 1 Coil

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Repair availability chart updated. Work instructions updated to reflect data matrix code on the new inflators.

Repair availability chart updated. Work instructions updated to reflect data matrix code on the new inflators. Safety Recall Code: 69R6 Revision Subject Revision Summary Driver Frontal Airbag Inflator (Takata) Repair availability chart updated. Work instructions updated to reflect data matrix code on the new inflators.

More information

Operation Manual. O2 Quickstick. Oxygen Analyzer

Operation Manual. O2 Quickstick. Oxygen Analyzer Operation Manual O2 Quickstick Oxygen Analyzer 01.11 www.nuvair.com If you have any questions on this equipment please contact Technical Support at: Nuvair 2949 West 5 th St. Oxnard, CA 93030 Phone: 805-815-4044

More information

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout)

DuPage County Environmental, Safety, Health & Property Loss Control Program Hazardous Energy Control (Lockout/Tagout) Purpose: To provide the minimum requirements for the lockout or tagout of energy isolating devices whenever work is performed or servicing is done on County of DuPage machinery, equipment, vehicles and

More information

COOPER POWER SERIES. Series winding ratio test procedure instructions. Voltage Regulators MN225060EN. 120 Vac VOLTMETER

COOPER POWER SERIES. Series winding ratio test procedure instructions. Voltage Regulators MN225060EN. 120 Vac VOLTMETER Voltage Regulators MN225060EN Effective February 2017 Supersedes January 2012 (S225-60-2) Series winding ratio test procedure instructions COOPER POWER SERIES 120 Vac VOLTMETER S L SL DISCLAIMER OF WARRANTIES

More information

Macro-Infusion Guide

Macro-Infusion Guide 115v and 12v System Macro-Infusion Guide Macro-Infusion rapidly introduces a large volume of solution directly into a tree s vascular system. Macro-infusion delivers complete and even distribution of solution

More information

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions

222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions 222 Schwinn Recumbent Exercise Bike Parts List Full Size Hardware Chart Product Illustration Assembly Instructions FITNESS SAFEGUARDS AND WARNINGS Before starting any exercise program, consult with your

More information

TECHNICAL DATA BROCHURE - ZTR 428 & 429

TECHNICAL DATA BROCHURE - ZTR 428 & 429 TECHNICAL DATA BROCHURE - ZTR 428 & 429 DATE 8/89 (Rev.) MPORTANT -- READ OPERATOR S MANUAL BEFORE OPERATING OR MAKING ADJUSTMENTS. Deluxe Seat Adjustment Easy hand lever action allows forward and backward

More information

AUTO PUMP STATUS CENTER

AUTO PUMP STATUS CENTER INSTRUCTION MANUAL AUTO PUMP STATUS CENTER PRESSURE ONLY MODEL #: 091-198-12-AP File: IM_091-198-12-AP_revD.indd Rev: D, pg 3 WD Revised By: PSS Date: 2-01-2016 3 YEAR WARRANTY INTRODUCTION The Auto Pump

More information

Nicheless LED Lighted Bubbler

Nicheless LED Lighted Bubbler OWNER S MANUAL ENGLISH FRANÇAIS ESPAÑOL Jandy Pro Series Nicheless LED Lighted Bubbler WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

Inflatable Restraint Steering Wheel Module Replacement

Inflatable Restraint Steering Wheel Module Replacement Document ID# 804636 2001 Chevrolet/Geo Chevy C Silverado - 2WD Inflatable Restraint Steering Wheel Module Replacement Removal Procedure This vehicle is equipped with a Supplemental Inflatable Restraint

More information

Installation, Operation & Maintenance Instructions

Installation, Operation & Maintenance Instructions Installation, Operation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information Read this manual carefully

More information

DEEPSEA. Sealite Sphere 6500 POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA

DEEPSEA. Sealite Sphere 6500 POWER & LIGHT. Operator s Manual. Original Instruction Ruffin Road San Diego, CA USA DEEPSEA POWER & LIGHT Sealite Sphere 6500 Record product serial number below as it appears on the nameplate. Serial # Pin-outs Positive = Pin Negative = Pin Ground = Pin Dimming (if applicable) = Pin T:

More information

R E D I C O N T R O L S

R E D I C O N T R O L S R E D I C O N T R O L S Operation & Maintenance Manual Portable Service Purger for Low Pressure Chillers Model: PSP-LP-1B For Refrigerants R-11, R-113, R-114 & R-123 & Other Similar Refrigerants File Literature

More information

VX Series Salt Chlorinator T Model

VX Series Salt Chlorinator T Model VX Series Salt Chlorinator T Model OPERATING INSTRUCTIONS www.hurlcon.com.au email: service@hurlcon.com.au Information and specifications subject to change without notice. Melbourne: Ph: (03) 9765 9700

More information

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection

TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection Model no. 009-5032-6 TWIN CYLINDER RAPID INFLATOR With Direct Battery Connection IMPORTANT: Questions, problems, missing parts or for technical service? Before returning to your retailer, call our customer

More information

GM Series Dual-Block Multi-Function Gas Control Valves

GM Series Dual-Block Multi-Function Gas Control Valves Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin GM Issue Date 0297 GM Series Dual-Block Multi-Function Gas Control Valves Figure 1: GM Series

More information

GATE 2 Part No

GATE 2 Part No PAGE 1 GATE 2 Part No. 23001125 SWING GATE CTROLLER INSTALLATI GUIDE Page 2 GATE 2 Code No. 23001125 Electronic Control Board for use with SEA Hydraulic or Electro-mechanical swing gate operators (without

More information

ELIMINATOR INSTRUCTIONS Table of Contents

ELIMINATOR INSTRUCTIONS Table of Contents ELIMINATOR INSTRUCTIONS Table of Contents 1. PRACTICE MODE A. Toggling from Full to Pro Tree B. Toggling from 1 to 2 Users C. Toggling from Auto to Manual Reset D. Setting the Delay Boxes E. Setting a

More information

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii

Misaligned Folds Paper Feed Problems Double Feeds Won t Feed FLYER Won t Run iii Operator s Manual Table of Contents Operator Safety... 1 Introduction... 2 Unpacking and Setup... 3 Unpacking... 3 Setup... 4 FLYER Overview... 5 FLYER Diagram... 5 Capabilities... 5 Control Panel... 6

More information

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA

DEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA SeaLite Six DEEPSEA POWER & LIGHT Record product serial number below as it appears on the nameplate. Serial # Pin-out Postive = Pin Negative = Pin Ground = Pin Dimming (if applicable) = Pin T: (858) 576-1261

More information

EVAP LEAK DTC DIAGNOSIS

EVAP LEAK DTC DIAGNOSIS Classification: Reference: Date: EC09-001d NTB09-020d vember 18, 2011 EVAP LEAK DTC DIAGNOSIS This bulletin has been amended. APPLIED VEHICLES and the REPAIR FLOW CHART have been amended. Please discard

More information

Aquavar SOLO 2 Frequently Asked Questions

Aquavar SOLO 2 Frequently Asked Questions Aquavar SOLO 2 Frequently Asked Questions How do I size the Aquavar SOLO 2 for the appropriate pump/motor combination? Can I use a 208 Volt motor? Can I run the Aquavar SOLO 2 up to 80HZ? What are the

More information

User Manual for Amron International Diving Supply, Inc.

User Manual for Amron International Diving Supply, Inc. User Manual for Amron International Diving Supply, Inc. Model 2810E and 2810E-1 One Diver Communicator S/N This manual and the information contained herein are provided for use as an operation and maintenance

More information

RPS900W Redundant Power Supply. Installation Guide.

RPS900W Redundant Power Supply. Installation Guide. RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A

More information

11/2/2017. Course Objectives. Overview

11/2/2017. Course Objectives. Overview Course Objectives The objective of this CBT module is to insure that personnel receive basic training in electrical safety. Every employee's work involves electricity. This may vary from typical electrical

More information

Safe Schools: A Health and Safety Check

Safe Schools: A Health and Safety Check Name of School: Optional Information Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Use of Electrical Equipment Self-Inspection Checklist Guidelines: This checklist covers

More information

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL NUMBER: P PORTABLE COMPRESSOR MODEL NUMBER: 44043-440P PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product.

More information

480C DUAL PERFORMANCE VALUE PACK

480C DUAL PERFORMANCE VALUE PACK (Pewter) PART NO. 48012 (Chrome) PART NO. 48032 (Stealth Black) PART NO. 48042 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions

AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP General User and Maintenance Instructions AMP Oil Free Manual AMP 50-8-TC AMP 50-6-D AMP 50-24 General User and Maintenance Instructions Silentaire Technology 8614 Veterans Memorial Dr. Houston, TX 77088 800-972-7668 Fax 832-327-0669 www.silentaire.com

More information

Operating Instructions

Operating Instructions Addingham Cricket Club, Leeds Operating Instructions Introduction Bespoke Scoreboards Operating Instructions The information displayed on your Scoreboard is changed using the Scoreboard controller. This

More information

MODEL 100 NITROGEN INFLATION CART

MODEL 100 NITROGEN INFLATION CART MODEL 100 NITROGEN INFLATION CART Installation & Operation Information Branick Industries, Inc. 4245 Main Avenue P.O. Box 1937 Fargo, North Dakota 58103 REV120106 P/N: 81-0113 TABLE OF CONTENTS SAFETY

More information

TR Electronic Pressure Regulator. User s Manual

TR Electronic Pressure Regulator. User s Manual TR Electronic Pressure Regulator Page 2 of 13 Table of Contents Warnings, Cautions & Notices... 3 Factory Default Setting... 4 Quick Start Procedure... 5 Configuration Tab... 8 Setup Tab... 9 Internal

More information

TECHNICAL DATA. Trimpac 257a. September 16, 2013

TECHNICAL DATA. Trimpac 257a. September 16, 2013 September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking

More information