Effective September, 2005 Copyright 2005 PAGE
|
|
- Dale Goodman
- 5 years ago
- Views:
Transcription
1 -42 DTX Junction Boxes: Dust-Ignitionproof, Watertight Cast iron box and cover for surface mounting. Cast aluminum box and cover for surface mounting. Applications DTX dust tight and watertight boxes are specially designed and constructed for hazardous locations where ignitable dusts, fibers or flyings are present. These dust tight and watertight boxes are specially designed and constructed for use in hazardous locations under the classifications shown below. For use in grain elevators or other grain storage areas. Tissue paper mills, coal storage facilities, textile factories and any other areas where ignitable dusts, fibers or flyings are present. Features Cast iron box and cover. Mounting lugs. Mechanically attached vellumoid gaskets. Stainless steel cover bolts. Standard Materials Bodies and covers: cast iron. Gasket: vellumoid. Cover bolts: stainless steel. Standard Finish Hot dip galvanized finish (cast iron only). Optional Materials Cast aluminum box and cover. Add suffix - A. Compliances UL Listed - Standard 886 NEMA 4, 9EFG. PAGE 42
2 Class II, Div. 1 and 2 Groups E,F,G Class III NEMA 4,9EFG DTX Junction Boxes: Dust-Ignitionproof, Watertight Cast iron box and cover for surface mounting. Cast aluminum box and cover for surface mounting. -43 Approx. Max.* Thick Conduit Inside Dim. Iron Alum. Side Size (Inches) Wt. Wt. Catalog Walls (In.) (In.-NPT) L x W x D (lbs.) (lbs.) Number 1/4 3/4 4 x 4 x DTX /4 3/4 4 x 4 x DTX /4 3/4 5 x 5 x DTX /4 3/4 6 x 4 x DTX /4 3/4 6 x 4 x DTX /4 3/4 6 x 6 x DTX /4 3/4 6 x 6 x DTX /4 3/4 6 x 6 x DTX /4 3/4 8 x 4 x DTX /4 3/4 8 x 4 x DTX /4 3/4 8 x 6 x DTX /4 3/4 8 x 6 x DTX /4 3/4 8 x 6 x DTX /4 3/4 8 x 8 x DTX /4 3/4 8 x 8 x DTX /4 3/4 8 x 8 x DTX /4 3/4 10 x 6 x DTX /4 3/4 10 x 6 x DTX /4 3/4 10 x 8 x DTX /4 3/4 10 x 8 x DTX /4 3/4 10 x 8 x DTX /4 3/4 10 x 10 x DTX /4 3/4 10 x 10 x DTX /4 3/4 10 x 10 x DTX /4 3/4 12 x 4 x DTX /4 3/4 12 x 6 x DTX /4 3/4 12 x 6 x DTX /4 3/4 12 x 8 x DTX /4 3/4 12 x 8 x DTX /4 3/4 12 x 8 x DTX /4 3/4 12 x 10 x DTX /4 3/4 12 x 10 x DTX /4 3/4 12 x 10 x DTX /4 3/4 12 x 12 x DTX /4 3/4 12 x 12 x DTX / x 12 x DTX / x 12 x DTX / x 12 x DTX / x 12 x DTX /4 3/4 14 x 8 x DTX /4 3/4 14 x 8 x DTX /4 3/4 14 x 8 x DTX / x 14 x DTX / x 14 x DTX Approx. Max.* Thick Conduit Inside Dim. Iron Alum. Side Size (Inches) Wt. Wt. Catalog Walls (In.) (In.-NPT) L x W x D (lbs.) (lbs.) Number 5/ x 14 x DTX /32 3/4 16 x 12 x DTX /32 3/4 16 x 12 x DTX /32 3/4 16 x 12 x DTX / x 16 x DTX /32 3/4 18 x 6 x DTX /32 3/4 18 x 8 x DTX /32 3/4 18 x 8 x DTX /4 3/4 18 x 12 x DTX /32 3/4 18 x 12 x DTX / x 12 x DTX / x 12 x DTX / x 12 x DTX / x 12 x DTX / x 18 x DTX / x 18 x DTX / x 18 x DTX / x 18 x DTX / x 12 x DTX / x 12 x DTX / x 12 x DTX / x 18 x DTX / x 18 x DTX / x 18 x DTX / x 18 x DTX / x 24 x DTX / x 24 x DTX / x 24 x DTX / x 24 x DTX / x 12 x DTX / x 12 x DTX / x 24 x DTX / x 24 x DTX / x 24 x DTX / x 24 x DTX / x 18 x DTX / x 18 x DTX / x 18 x DTX / x 18 x DTX / x 24 x DTX / x 36 x DTX / x 36 x DTX / x 36 x DTX *Type DTX boxes must have a minimum of 3-1/2 full threads at all conduit entrances. The Max. Conduit Size listed herein indicates the maximum drilled and tapped conduit entrance which can be machined into the four unbossed sides of a given box to provide these 3-1/2 full threads. If larger conduit openings than those listed herein are required, bosses can be supplied by us at an additional cost to provide the minimum 3-1/2 full thread requirement. In addition to the minimum 3-1/2 full thread requirement, the length of thread at conduit entrances must also be at least 1/4. A 3/8 conduit entrance therefore requires a minimum of a 1/4 wall thickness. For aluminum box and cover, add suffix A. PAGE 43
3 -44 DTX Series: Dimensions Outside Flange Dimensional Data A E-MTG C D M Useable Conduit Area P S Opening Useable Conduit Area M X X B F MTG Front View G Dia. Side View L/2 L T Opening Front View Less Cover J N/2 N End View P Y Section View Z Mounting Mtg Clear Wall Overall Enclosure Enclosure Thk Depth Conduit Area Opening Thickness Catalog A B C D E F G J L M N P S T X Y Z Number 5-9/16 5-9/ /32 3-5/32 5-9/16 3 5/16 1/ /2 2-5/16 3-1/2 7/ /32 3/16 5/32 DTX /16 5-9/ /32 4-5/32 5-9/16 4 5/16 1/ /2 2-5/16 3-1/2 7/ /32 3/16 5/32 DTX / /16 4-3/8 4-3/16 6-1/2 4 5/16 1/ /2 3-5/16 3-1/2 7/ /16 3/16 3/16 DTX /16 7-9/ /32 3-5/32 5-3/8 5 5/16 1/ /2 2-5/16 3-1/2 7/ /32 3/16 5/32 DTX /16 7-9/ /32 4-5/32 5-3/8 5 5/16 1/ /2 3-5/16 3-1/2 7/ /32 3/16 5/32 DTX / /16 3-3/8 3-3/16 7-1/2 4 3/8 1/ /2 2-1/4 5-1/2 7/ /16 3/16 3/16 DTX / / /32 4-7/32 7-1/2 4 3/8 1/ /2 3-1/4 5-1/2 7/ /32 3/16 7/32 DTX / / /32 6-7/32 7-1/2 4 3/8 1/ /2 6-1/4 5-1/2 7/ /16 3/16 3/16 DTX / /16 3-7/16 3-3/16 5-1/2 5 3/8 1/ /2 2-1/4 3-1/2 7/ /16 1/4 3/16 DTX / /16 4-7/16 4-3/16 5-1/2 5 3/8 1/ /2 3-1/4 3-1/2 7/ /16 1/4 3/16 DTX / / /32 3-7/32 7-5/8 5 3/8 1/ /2 2-1/4 5-1/2 1/ /32 1/4 7/32 DTX / / /32 4-7/32 7-5/8 5 3/8 1/ /2 3-1/4 5-1/2 1/ /32 1/4 7/32 DTX / / /32 6-7/32 7-5/8 5 3/8 1/ /2 5-1/4 5-1/2 1/ /32 1/4 7/32 DTX / / /32 4-7/32 9-5/8 5 3/8 1/ /2 3-1/4 7-1/2 1/ /32 1/4 7/32 DTX / / /32 6-7/32 9-5/8 5 3/8 1/ /2 5-1/4 7-1/2 1/ /32 1/4 7/32 DTX / / /32 8-7/32 9-5/8 5 3/8 1/ /8 7-1/4 7-3/8 1/ /32 1/4 7/32 DTX / / /32 4-7/32 7-5/8 7 3/8 1/ /2 3-1/4 5-1/2 1/ /32 1/4 7/32 DTX / / /32 6-7/32 7-5/8 7 3/8 1/ /2 5-1/4 5-1/2 1/ /32 1/4 7/32 DTX / / /32 4-1/4 9-3/4 7 3/8 1/ /2 3-1/4 7-1/2 1/ /4 9/32 1/4 DTX / / /32 6-1/4 9-3/4 7 3/8 1/ /2 5-1/4 7-1/2 1/ /4 9/32 1/4 DTX / / /32 8-1/4 9-3/4 7 3/8 1/ /8 7-1/4 7-3/8 1/ /4 9/32 1/4 DTX / / /32 4-1/4 11-5/8 7 3/8 1/ /2 3-1/4 9-1/2 1/ /4 9/32 1/4 DTX / / /32 6-1/4 11-5/8 7 3/8 1/ /2 5-1/4 9-1/2 1/ /4 9/32 1/4 DTX / / /32 8-1/4 11-5/8 7 3/8 1/ /8 7-1/4 9-3/8 1/ /4 9/32 1/4 DTX / /16 4-1/2 4-1/4 5-3/8 8 3/8 1/ /2 3-1/4 3-1/2 1/ /4 1/4 1/4 DTX / / /32 4-1/4 8-3/8 8 7/16 3/ /2 3-1/4 5-1/2 1/ /4 9/32 1/4 DTX / / /32 6-1/4 8-3/8 8 7/16 3/ /2 5-1/4 5-1/2 1/ /4 9/32 1/4 DTX Note: All dimensions are in inches. PAGE 44
4 DTX Series: Dimensions -45 Outside Flange Dimensional Data Mounting Mtg Clear Wall Overall Enclosure Enclosure Thk Depth Conduit Area Opening Thickness Catalog A B C D E F G J L M N P S T X Y Z Number 10-1/ / /32 4-1/4 10-3/8 8 7/16 3/ /2 3-1/4 7-1/2 1/ /4 9/32 1/4 DTX / / /32 6-1/4 10 3/8 8 7/16 3/ /2 5-1/4 7-1/2 1/ /4 9/32 1/4 DTX / / /32 8-1/4 10-3/8 8 7/16 3/ /8 7-1/4 7-3/8 1/ /4 9/32 1/4 DTX / / /32 4-1/4 12-3/8 8 7/16 3/ /2 3-1/4 9-1/2 1/ /4 9/32 1/4 DTX / / /32 6-1/4 12-3/8 8 7/16 3/ /2 5-1/4 9-1/2 1/ /4 9/32 1/4 DTX / / /32 8-1/4 12-3/8 8 7/16 3/ /2 7-1/4 9-3/8 1/ /4 9/32 1/4 DTX / /16 4-9/16 4-1/4 14-3/8 8 7/16 3/ /8 3-3/ /2 1/ /4 5/16 1/4 DTX / /16 6-9/16 6-1/4 14-3/8 8 7/16 3/ /2 5-3/ /2 1/ /4 5/16 1/4 DTX / /16 7-5/8 7-5/ /8 8 7/16 3/ /8 6-3/ /8 9/ /16 5/16 5/16 DTX / /16 8-5/8 8-5/ /8 8 7/16 3/ /8 7-3/ /8 9/ /16 5/16 5/16 DTX / / /8 10-5/ /8 8 7/16 3/ /4 9-3/ /4 9/ /16 5/16 5/16 DTX / / /8 12-5/ /8 8 7/16 3/ /4 11-3/ /4 9/ /16 5/16 5/16 DTX / / /32 4-1/4 10-3/8 10 7/16 3/ / /4 5/ /4 9/32 1/4 DTX / / /32 6-1/4 10-3/8 10 7/16 3/ / /4 5/ /4 9/32 1/4 DTX / / /32 8-1/4 10-3/8 10 7/16 3/ / /8 5/ /4 9/32 1/4 DTX /8 16-5/8 6-19/32 6-9/ /2 10 7/16 3/ /4 4-15/ /4 11/ /32 5/16 9/32 DTX /8 16-5/8 8-19/32 8-9/ /2 10 7/16 3/ /4 6-16/ /4 11/ /32 5/16 9/32 DTX /8 16-5/ / / /2 10 7/16 3/ / / /32 5/16 9/32 DTX /8 18-5/8 4-19/32 4-9/ /2 12 7/16 3/ /4 2-15/ /4 11/ /32 5/16 9/32 DTX /8 18-5/8 6-19/32 6-9/ /2 12 7/16 3/ /4 4-15/ /4 11/ /32 5/16 9/32 DTX /8 18-5/8 8-19/32 8-9/ /2 12 7/16 3/ / / /32 5/16 9/32 DTX /8 18-5/8 6-5/8 6-5/ /2 12 7/16 3/ / /4 11/ /16 5/16 5/16 DTX / / /32 6-9/32 8-1/2 13 7/16 3/ /4 4-15/16 5-1/4 11/ /32 5/16 9/32 DTX / / /32 4-9/ /2 13 7/16 3/ /4 2-15/16 7-1/4 11/ /32 5/16 9/32 DTX / / /32 6-9/ /2 13 7/16 3/ /4 4-15/16 7-1/4 11/ /32 5/16 9/32 DTX /8 20-5/8 4-9/16 4-1/4 14-3/8 13 7/16 3/ /4 2-15/ /4 5/ /4 5/16 1/4 DTX /8 20-5/8 6-19/32 6-9/ /8 13 7/16 3/ /4 4-15/ /4 11/ /32 5/16 9/32 DTX /8 20-5/8 8-5/8 8-5/ /8 13 7/16 3/ / / /16 5/16 5/16 DTX /8 20-5/8 10-5/8 10-5/ /8 13 7/16 3/ / / /16 5/16 5/16 DTX /8 20-5/8 12-5/8 12-5/ /8 13 7/16 3/ / / /8 11/ /16 5/16 5/16 DTX /8 20-5/ / / /8 13 7/16 3/ / / /4 3/ /32 5/16 11/32 DTX / /16 6-5/8 6-5/ /8 13 9/16 3/ /4 4-15/ /4 11/ /16 5/16 5/16 DTX / /16 8-5/8 8-5/ /8 13 9/16 3/ /4 6-15/ /4 11/ /16 5/16 5/16 DTX / / /8 12-5/ /8 13 9/16 3/ / / /16 5/16 5/16 DTX / /16 1-5/8 12-5/ /8 13 9/16 3/ / / /16 5/16 5/16 DTX / /16 6-5/8 6-5/ /8 19 9/16 3/ /4 4-15/ /4 11/ /16 5/16 5/16 DTX / /16 8-5/8 8-5/ /8 19 9/16 3/ /4 6-15/ /4 11/ /16 5/16 5/16 DTX / / /8 12-5/ /8 19 9/16 3/ / / /16 5/16 5/16 DTX / / / / /8 19 9/16 3/ /4 4-7/8 17-1/4 3/ /32 3/8 11/32 DTX / / / / /8 19 9/16 3/ /4 6-7/8 17-1/4 3/ /32 3/8 11/32 DTX / / / / /8 19 9/16 3/ /8 17 3/ /32 3/8 11/32 DTX / / / / /8 19 9/16 3/ /8 17 3/ /32 3/8 11/32 DTX / / / / /8 19 9/16 3/ /8 17 3/ /32 3/8 11/32 DTX / / / / /8 19 9/16 3/ /4 4-7/8 23-1/4 3/ /32 3/8 11/32 DTX / / / / /8 19 9/16 3/ /4 6-7/8 23-1/4 3/ /32 3/8 11/32 DTX / / /4 10-3/8 26-7/8 19 9/16 3/ /8 23 3/ /8 3/8 3/8 DTX / /16 1-3/4 12-3/8 26-7/8 19 9/16 3/ /8 23 3/ /8 3/8 3/8 DTX / / / / /4 22 9/16 3/ /8 11 3/ /32 11/32 11/32 DTX / / / / /4 22 9/16 3/ /8 11 3/ /32 11/32 11/32 DTX /4 33-1/4 8-3/4 8-3/8 26-7/8 24 9/16 3/ /4 8-7/8 23-1/4 3/ /8 3/8 3/8 DTX /4 33-1/4 10-3/4 10-3/8 26-7/8 24 9/16 3/ /4 8-7/8 23-1/4 3/ /8 3/8 3/8 DTX /4 33-1/4 12-3/4 12-3/8 26-7/8 24 9/16 3/ /4 10-7/8 23-1/4 3/ /8 3/8 3/8 DTX /4 33-1/4 18-3/4 18-3/8 26-7/8 24 9/16 3/ /8 23 3/ /8 3/8 3/8 DTX /4 39-1/4 6-3/4 6-3/8 20-7/8 30 9/16 3/ /4 4-7/8 17-1/4 3/ /8 3/8 3/8 DTX /4 39-1/4 8-3/4 8-3/8 20-7/8 30 9/16 3/ /4 6-7/8 17-1/4 3/ /8 3/8 3/8 DTX /4 39-1/4 12-3/4 12-3/8 20-7/8 30 9/16 3/ /8 17 3/ /8 3/8 3/8 DTX /4 39-1/4 18-3/4 18-3/8 20-7/8 30 9/16 3/ /8 17 3/ /8 3/8 3/8 DTX /8 8-7/8 38-7/8 30 9/16 3/ / / /16 7/16 7/16 DTX /8 10-7/8 38-7/8 30 9/16 3/ / / /16 7/16 7/16 DTX /8 12-7/8 38-7/8 30 9/16 3/ / / /16 7/16 7/16 DTX /8 18-7/8 38-7/8 30 9/16 3/ /8 16-3/4 34-7/8 13/ /16 7/16 7/16 DTX Note: All dimensions are in inches. PAGE 45
5 -46 EXB and DTX Series: Drill and Tap Schedule Ordering Information: ARE INDICATED CON- DUIT SIZES WITHIN THE CATALOG PUBLISHED MAXIMUM ON PAGES - 40 AND -43? CHEC FOR MINIMUM SPACING BETWEEN CONDUIT OPENINGS PER CONDUIT SPACING TABLE, ON PAGE -41. ENCLOSURE PAGE 46
XCE: Explosionproof Control Enclosures
XCE SERIES XCE: Explosionproof Control Enclosures FEATURES 64 standard sizes available Pre-drilled for hinges (hinges optional) Pre-drilled for sub-panel (sub-panel optional) One-piece, NEMA 4 water-tight
More informationECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.
ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical
More informationECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.
ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical
More informationDie Cast Aluminum Conduit Outlet Bodies, Covers & Gaskets
Covers & s die cast copper-free aluminum conduit bodies, covers and gaskets are available for use with rigid or EMT conduit (with set screw). Conduit bodies are available in trade sizes /2 to 4, in the
More informationGalvanized Rigid Conduit
Galvanized Rigid Conduit Conforms To: C80.1 - UL 6 ANSI C-80.1 UL Min. WGT. Per 100 Feet in LBS. INCL. CP. O.D. I.D. Thickness Threads Per Inch Feet Per Lift Color Code Thread Protector 1/2" 79.840.632.104
More informationAMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS
AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS DESIGNED TO HOLD THE WEIGHT FOR ELECTRICAL CABLE AS IT HANGS IN VERTICAL, SLOPING OR HORIZONTAL POSITIONS. EASILY INSTALLED AND REMOVED USING NO
More informationBoxes & Mounting Accessories 10-1
Boxes & Mounting Accessories 10-1 ROUND BOXES & ROUND COVERS 3-1/2 ROUND BOXES 4 Hole and 6 Hole Body Side Back Cover Mtg. Pipe holes hole hole Lugs Plugs Thread Size 29 4 1 1 4 27 4 1 1 2 4 27 75 4 ROUND
More informationWELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD
WELL COMPLETION & PROTECTION MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD www..com WELL COMPLETION & PROTECTION TABLE OF CONTENTS TABLE OF CONTENTS (FLUSHMOUNTS)... 2-5 MONITORING
More informationPipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3
Worldwide Contacts www.tyco-fire.com Model B-1 Pipe Line Strainer General Description The Model B-1 Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply connection
More informationVAREC 180 SERIES PRESSURE REGULATORS
Double port regulators with a variety of model options for upstream and downstream pressure control FETURES Large diaphragm and a unique double port design achieve a sensitivity of less than 5%. Set pressure
More informationSLEEVED PLUG VALVES 2-WAY
Specialty Valves 2-WAY ANSI/ASME CLASS 150 LBS Dimensions to ANSI B16.5 & B16.10 1 Six (6) top holes * 2 1/2 valves are made from 3 casting, but flanges are machined to 2 1/2 dimensions 1/2 4.25 108.00
More informationSLEEVED PLUG VALVES 2-WAY
Specialty Valves 2-WAY ANSI/ASME CLASS 150 LBS Dimensions to ANSI B16.5 & B16.10 1 Six (6) top holes * 2 1/2 valves are made from 3 casting, but flanges are machined to 2 1/2 dimensions 1/2 4.25 108.00
More informationFoundation Products. Poured In Ground Anchor Bolts E1 - E4. Structural Foundations E5 - E12. Copyright 2016 s Industry Inc. SIE-RA-CMP EN
Foundation Products Poured In Ground Anchor Bolts E1 - E4 Structural Foundations E5 - E12 EA EB Poured in Ground Anchor Bolts Layout SIEMENS Anchor Bolts 131702-4X shown for reference purposes only! Actual
More informationFord Service Saddles and Tapping Sleeves
Section AA 5/2001 Ford Service Saddles and Tapping Sleeves The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487
More informationSV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series
SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified
More informationVG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators
VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 1, 01 VGG VGD0 VGD0 Description Only when assembled to Series SKP actuators
More informationVG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators
VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP
More informationSafidDampers. Class 1A & Class 1 Low Leakage Volume Control Damper ( Flange Type ) SPK Standard Construction. Description SPK
( Flange Type ) SPK 30 400 Standard Construction FRAME: 60mm x 30mm x.5mm (6 Ga.) galvanized steel formed channel for flange connection. BLADES: 00mm, 5mm and 50mm wide airfoil shaped blades extruded aluminum.
More informationNorth American Simplex Basket Strainers for Gas and Oil
Combustion North American Simplex Basket Strainers for Gas and Oil A mesh lining (304 stainless standard or 316 stainless or monel special), either 20, 40 or 100 mesh, can be provided, depending on the
More informationCLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS IN GAS UTILITY AREAS. Gerry Pickens
CLASSIFICATION OF LOCATIONS FOR ELECTRICAL INSTALLATIONS IN GAS UTILITY AREAS Gerry Pickens Atmos Energy 810 Crescent Centre Drive Franklin, TN 37067 The National Electrical Code (NEC) defines hazardous
More informationBASIC NATIONAL ELECTRIC CODE APPLICABLE TO MEASUREMENT. Gerry Pickens. Atmos Energy 810 Crescent Centre Drive Franklin, TN 37067
BASIC NATIONAL ELECTRIC CODE APPLICABLE TO MEASUREMENT The National Electrical Code (NEC) defines hazardous locations as those areas "where fire or explosion hazards may exist due to flammable gases or
More informationMUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.
Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read
More informationAWWA C504 COMPLIANT VALVES FROM 3 THRU 108
AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly
More informationNorth American Orifice Metering System
Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual
More informationZ, Y, and X PURGE INDICATORS / CONTROLLERS
PurgEx XXXXXX Z, Y, and X PURGE INDICATORS / CONTROLLERS PURGE / PRESSURIZATION PURGE / PRESSURIZATION XXXXX XXXXXXXXX 8626 SERIES Globally Certified Z,Y,X Purge Indicators / Controllers and Accessories
More informationEnd Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A
Worldwide Contacts www.tyco-fire.com Model RV-1 Pressure Relief Valve, Pilot-Operated, Globe and Angle Body Styles General Description Valves, through inch (DN50 through DN00), are factory assembled and
More informationWeatherproof Products
Red ot Iberville arlon Weatherproof Products S oxes and overs pplications : S boxes are S approved for wet locations S device boxes are installed in applications that require a rugged unit to accept wiring
More informationBUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-
BUTTERFLY VALVES 1. General HyrdoWer is a globally recognized manufacturer of power unit accessories. They have become specialists in the design of Butterfly Valves and Hydraulic Compensators. The shut
More information44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES
WALL BOXES IN GWPLAST 75 - GWT 650 C GWT 650 C TP 85 C WALLS WITH CABLE GLAND - IP44 AND IP55 GW44001 JUNCTION BOXES WITH PLAIN PRESS-ON LID - IP44 - GREY RAL 7035 LxHxD (mm) No. holes / Ø GW 44 001 Ø
More informationMLS Series Liquid Level Switches. Installation and Operations Manual Section 15
MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right
More informationOHIO GEAR REDUCERS DESIGN FEATURES
REDUCERS Cast Iron NEMA C Flange with machined fits for precision alignment for motor and bearings. Seal Guard on quill-input styles protects input seals from damage during motor installation. Oversized
More informationNorth American 7337A/B/C-4 High Pressure Gas Regulators
Combustion North American A/B/C-4 High Pressure Gas Regulators Bulletin A/B/C-4 A-4, B-4 and C-4 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the
More informationHoist Ring Forged Hoist Ring Machined Hoist Ring (Metric) Hoist Ring Swivel Shoulder Eyebolts JD Weld-On Alloy Lifting
Hoist Ring Forged........................... 94 Hoist Ring Machined........................ 95 Hoist Ring (Metric).......................... 96 Hoist Ring Swivel........................... 97 Shoulder
More informationTYPE: LSF - LIFTING STUD FOOT ANCHOR DESCRIPTION: The design of the anchor means no additional reinforcement is required as the forces are transferred into the concrete from the design of the foot of the
More information300lb MALLEABLE FITTINGS
NIPPLES & FITTINGS MLLEBLE FITTINGS MLLEBLE FITTINGS MLLEBLE FITTINGS ISO 9002 - CERTIFICTE OF QULITY - UL/ LISTED ND PPROVED T 300 PSI Our quality fittings are made with care and attention to detail.
More informationCFC2. Float Control For Closed Tanks MODEL. Specifications. Dimensions (In Inches) Reservoir Connection 1" NPT (Typ. Both Ends 2 Places)
MODEL Float Control For Closed Tanks Accurate Liquid Level Control Fully Hydraulic Operation Simple Design, Easy Maintenance No Lubrication Necessary No Gears, No Mechanical Linkage Between Valve and Control
More informationHEAVY DUTY PNEUMATIC
HEAVY DUTY PNEUMATIC Series A4 MEDIUM DUTY HYDRAULIC Series H4 PERMANENTLY LUBRICATED HEAVY DUTY PNEUMATIC Series L4 586.778.7680 SERIES A4/L4/H4 39 A4/L4/H4 FEATURES 1 1 9 9 12 8 7 5 12 3 13 4 10 2 11
More informationSae 4 Bolt Flange Port Dimensions
We have made it easy for you to find a PDF Ebooks without any digging. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with sae 4 bolt flange port
More informationHANGERS & SUPPORTS CLIP-IT CLIP-IT STUD STRAPS BAR JOIST CLIP CONDUIT HANGERS CLIP-IT
62 hangers & supports Innovation. It s what Madison is all about. Check out our Madison Strap, the product that started it all. Invented in 1929 by our founder Earl Adkinson, Madison has been on the cutting
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationNominal Wall Thickness Steel Only in. (mm) Outside Diameter With PVC in. (mm)
PVC-Coated Conduit The ultimate in corrosion protection! OCAL-BLUE Conduit Hot-dip galvanized steel or aluminum conduit. Nominal.00 ( mils) blue urethane coating on interior. Hot-dipped galvanized threads
More informationAWWA Pipe Flanges. AWWA C Standard Steel Hub Flanges Class D AWWA C Standard Steel Hub Flanges Class E AWWA C Flange Manufacturer
WW Pipe Flanges WW Flanges are commonly used in waterworks, wastewater, slurry, plant piping or other light duty applications generally requiring pressures of less than 300 psi. Pressure ratings for WW
More informationSTANDARD TYPE 1 ENCLOSURE WITH KEYED LOCK
STANDARD TYPE 1 ENCLOSURE WITH KEYED LOCK Industry Standards UL 50, Type 1 Nema Type 1 UL File E235575 X BUTT HINGES H 1/4 TURN LATCH 1-3/8" KNOCKOUT ON ALL SIDES W PANEL (ORDER SEPARATELY) STIFFENER DETAIL
More informationWater. VAG DUOJET Automatic Air Valve Single-chamber type PN 10/16/25/40 - DN KAT-A 1912
Water VAG DUOJET Automatic Air Valve Single-chamber type Product characteristics and benefits Resilient seated With flange end acc. to EN 1092-2 Single chamber air valve in compact design Very high discharge
More informationDUPLEX TECHNICAL INFORMATION FABRICATED DUPLEX STRAINERS
DUPLEX STRAINER TECHNICAL INFORMATION - 119 - SCREEN OPENINGS 100 Mesh - 30% O.A. 0.006 Openings 80 Mesh - 36% O.A. 0.008 Openings 60 Mesh - 38% O.A. 0.010 Openings 40 Mesh - 41% O.A. 0.016 Openings 30
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationEPOXY FITTINGS DIMENSIONS
Bulletin No. A150 May 1, 2004 EPOXY FITTINGS DIMENSIONS 2"-16" GREEN THREAD fittings may be used with GREEN THREAD and RED THREAD II piping. Refer to Chemical Resistance Guide, Bulletin No. E5615, for
More informationFor Multi-Parameter Meters see mvx
Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid
More informationHorizontal Bladder Tanks
DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationVertical Bladder Tanks
DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationMUELLER. A A Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.
Installation Instructions manual MUELLER table of contents PAGE A-20806 A-20807 Adjustable General Information 2 Technical Data 3 Dimensions 4 Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator
More informationThe cost-efficient fixing for flexible use in non-cracked concrete VERSIONS. zinc-plated steel stainless steel hot-dip galvanised steel
The cost-efficient fixing for flexible use in non-cracked concrete VERSIONS APPROVALS zinc-plated steel stainless steel hot-dip galvanised steel BUILDING MATERIALS Approved for: Concrete C20/25 to C50/60,
More informationINTERLOCKED METAL HOSE
INTERLOCKED METAL HOSE HOSE FUNDAMENTALS Penflex interlocked metal hoses are made for a variety of specialized industrial applications and are available in a wide range of metals, styles and sizes. Interlocked
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationFLAME ARRESTOR MODEL L76C-UF
FLAME ARRESTOR MODEL L76C-UF Model L76C-UF The L76C-UF model is designed to inhibit flame propagation in gas piping systems and to protect low pressure tanks containing flammable liquids. Arrestors protect
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationFlow and Energy Measurement F-5400 THERMAL MASS FLOW METER
THERMAL MASS FLOW METER s Series Thermal Mass Flow Meters provide accurate and reliable flow measurement for natural gas, compressed air, and other industrial gas applications. Natural Gas Compressed Air
More informationNorth American Pressure Switches
Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are
More informationDual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
More informationMUELLER A A Non-Adjustable. Vertical Indicator Posts. Reliable Connections. General Information 2. Technical Data 3.
Installation Instructions manual MUELLER table of contents PAGE A-20808 General Information 2 Technical Data 3 Dimensions 4 A-20809 Non-Adjustable Installation 5-6 Parts 7 Maintenance 8 Vertical Indicator
More informationGas Pressure. Regulators Catalog. For Industrial Engines and Generator Sets. 2011, Maxitrol Company. All Rights Reserved.
Gas Pressure Regulators Catalog For Industrial Engines and Generator Sets 1 GAS PRESSURE REGULATORS For Industrial Engines and Generator Sets Service and or installation must be performed by a trained,
More informationCopper Bonded Ground Rod / Grounding Rods / Copper Bonded Earth Rod / Earthing rods
Copper Bonded Ground Rod / Grounding Rods / Copper Bonded Earth Rod / Earthing rods Copper bonded earth rods are made from low carbon Steel. Earth Rods are molecularly bonded with 99.9% pure electrolytic
More informationT Y P E V S A B M S E W A G E P U M P
Pe r fo r m a n ce C h a r t s 11 1 D R Y P I T S B U L L E T I N 2 3 9 8 7 6 5 4 3 2 1 12 11 1 / 4 1 1 / 2 9 3 / 4 9 5% 3 HP 5 HP 7 1/2 HP 1 HP 76% 5% C u r v e P a g e V S A B M - 4 1 1 5 R P M M O D
More informationMicro Motion H-Series Hygienic Coriolis Flow and Density Meters
Product Data Sheet PS-00599, Rev. E July 2009 Micro Motion H-Series Hygienic Coriolis Flow and Density Meters Micro Motion H-Series Coriolis meters offer highly accurate flow and density measurement for
More informationDorsey Standard Bore Gages
Dorsey Standard Bore Gages A time proven design made better by Dorsey This design of rugged production line bore gages has been an industry standard for more than 75 years. Dorsey offers precise replacement
More informationOUTER RACE SHIM SPACERS METRIC OUTER RACE SHIM SPACERS. All Dimensions in Millimeters. Material:300 Series Stainless Steel
OUTER RACE SHIM SPACERS Material:300 Series Stainless Steel METRIC OUTER RACE SHIM SPACERS All Dimensions in Millimeters Material:300 Series Stainless Steel 6-16 INNER RACE SHAFT SPACERS 3 /32" To 1 /2"
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationSKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25
More informationThread Gages Tolerances
Class X Thread Gage s on Half-Angle of Thread ± N NN' on Major or Minor Diameter on Pitch Diameter Above Above /2 Dia. 4 Dia. Through Through 4 Dia. 8 Dia. s Above 8 Dia. Through 2 Dia. Threads per Inch
More informationFIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:
LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are
More informationVRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators
VRD Series VRD40.xxxUx Double Valves for use with SKP... electro-hydraulic actuators Document No. 7649 VRD40.xxxUx ISO 9001 and 14001 REGISTERED FIRM Only with series SKPxx.xxxUx actuators Description
More informationVertical and Horizontal Bladder Tanks
DATA SHEET Vertical and Horizontal Tanks Application The ANSUL bladder tank is one component in a balanced pressure proportioning system. Its operation requires no external power other than a pressurized
More informationFeatures. Description
Features Fast response flow meter ideal for inert gas and liquid mass flow measurement applications Smart electronics permit field adjustment of critical flow meter settings Field validation of flow meter
More informationPRESSURE SWITCHES Bulletin 8757
PRESSURE SWITCHES Bulletin 8757 September 2013 Pressure switches are used with Automatic Shutoff Valves or solenoid valves to interrupt fuel fl ow in the event of fuel or air failure. They are also used
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationDual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series
Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure DMV-D/604L Series DMV-DLE/604L Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Listed
More informationModel MTB-ASME Horizontal Bladder Tanks
DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationFluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS
Fluid Dispensing Systems H O S E R E E L S H O S E S HOSE REELS HOSE REELS SIGNATURE SERIES H O S E S R E E L S FEATURES & BENEFITS Eight position locking precision die cast latch mechanism, with secure
More information-Proline Polypropylene Single Wall Piping
EFFECTIVE: 6/01/11 Industrial Piping Systems Dimensional Guide #PDIM Proline Super Proline Single Chemical Wall Grade Piping PVDF System -Proline Single Wall Piping s 3 r z s www.asahi-america.com Dimensions
More informationAutocalibration Systems For In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from
More informationType 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls
Type 1098-EGR and Type 1098H-EGR VL1000 FIELDVUE Pilot-Operated Valve Link Regulators Fisher Controls January 1982 Bulletin The Type 1098-EGR and Type 1098H-EGR regulators (figure 1) provide economical
More informationHUPF Series DESCRIPTION APPLICATION INSTRUCTION SHEET GAS PRESSURE REGULATOR WITH INCORPORATED FILTER EN1C-0003NL05 R1205.
HUPF Series GAS PRESSURE REGULATOR WITH INCORPORATED FILTER INSTRUCTION SHEET DESCRIPTION Spring-loaded regulator with inlet pressure compensation and zero shut-off. The outlet pressure is kept constant
More informationABB Instrumentation. Specifications. MagMaster Plus MFF Series Electromagnetic Sensors. MagMaster Plus bringing unsurpassed flowmetering performance
Specifications MagMaster Plus MFF Series Electromagnetic Sensors Unrivalled, fully traceable flow performance 0.15% accuracy Operable flow range: 1500:1 insures more precise revenue measurement superior
More informationENGINE/ PUMP ADAPTERS
ENGINE/ PUMP PTERS Hayes Manufacturing, Inc. Fife Lake, MI 9633 Phone: 23-879-3372 Fax: 23-879-330 TRNSMISSION PROUTS Fife Lake, MI 9633 Phone: 23-879-3372 Fax: 23-879-330 Table Of ontents Engine/ Mount
More informationPRODUCTS CATALOG
2017-2018 PRODUCTS CATALOG THE BROADEST LINE OF QUALITY ELECTRICAL FITTINGS & TUBULAR PRODUCTS PLUS THE BEST PERFORMANCE GUARANTEE IN THE INDUSTRY ABOUT US Electroline is committed to manufacturing quality
More informationDual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationPressure Regulator B-95
Pressure Regulator B-95 TYPE B WATER & AIR TYPE B INTERIOR WATER & AIR B SERIES VALVES DESTRIPTION The Cash Valve Series B pressure reducing and regulating valves are single seated, spring loaded, direct
More informationLevel transmitter LT 100
KROHNE 09/2001 7.02363.21.00 GR/PRINTO Level transmitter LT 100 Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationType S301 & S302 Gas Regulators INTRODUCTION INSTALLATION. Scope of Manual. Description. Specifications. Type S301 and S302. Instruction Manual
Fisher Controls Instruction Manual Type S301 & S302 Gas Regulators October 1981 Form 5180 WARNING Fisher regulators must be installed, operated, and maintained in accordance with federal, state, and local
More informationDual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series
Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each
More informationSECTION BUTTERFLY VALVES
SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class
More informationRated to the New, Higher Pressure Classes in Latest Editions of AWWA C900 and C909. Joint Restraint Products INFORMATION FEATURES & ADVANTAGES
Pipe Restrainers series 1000G2 1000G2C Restrainers for AWWA CI OD C900/C909 PVC/PVCO Pipe with MJ or Ductile Iron Push-On Fittings (Formerly Series 9000) INFORMATION Second Generation (Gen 2) PVC Restrainers
More informationREULAND DIRECT ACTING MAGNETIC DISC BRAKE ONLY ONE MOVING PART SIMPLE / DIRECT ACTING / TROUBLE FREE OPERATION
REULAND DIRECT ACTING MAGNETIC DISC BRAKE ONLY ONE MOVING PART SIMPLE / DIRECT ACTING / TROUBLE FREE OPERATION THE WORLD S SECOND SIMPLEST BRAKE DESIGN Concept / Design / Reality SEVEN MAJOR PARTS, ONLY
More informationData Sheet B-Series Switches Pressure, Differential Pressure & Hydraulic
FEATURES Adjustable setpoints 15-100% of range Fixed or limited adjustable deadband Wide selection of switch elements Explosion proof enclosure provides uncompromising protection Special designs for NACE
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationPlumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE.
Plumbing Products FLOOR DRAIN CLEANOUT GATE VALVE BALL VALVE www.wilsontaylor.co INTRODUCTION Wilson Taylor Asia Pacific, headquartered in Singapore with a subsidiary based in Hong Kong and a representative
More information