ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.
|
|
- Millicent Campbell
- 5 years ago
- Views:
Transcription
1 ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times.
2 ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical products for OEMs. 2 EATON S CROUSE-HINDS BUSINESS
3 ECP Series Explosionproof Enclosures Featuring an optimized design and fast lead times for OEMs, ECP Enclosures are available in 40 standard sizes with optional conduit and device drilling and tapping. Certifications and Compliances: Class I, Division 1 & 2, Groups B, C, D Class II, Division 1 & 2, Groups E, F, G Class III UL Standard 1203 cul to CSA C22.2 No. 30, No. 25 NEMA Type 3, 3R, 4, 7BCD, 9EFG Enclosure Type 4X (requires selecting 4X option) Standard Materials: Body and cover - Copper free aluminum Gasket - Neoprene Cover bolts - Steel Hinges - Aluminum Options (add to end of catalog number): PLT - Flat aluminum plate cover MP - Aluminum mounting plate installed S752 - Epoxy powder coat finish on exterior only S753 - Epoxy powder coat finish on interior and exterior S391 - Stainless steel cover bolts and hinges S756V - Breather and drain 4X - Stainless steel cover bolts, hinges, and external epoxy powder coat Available for sizes 12x12 and larger See your Crouse-Hinds representative for a full list of available options. Cover Devices: Pilot Lights Push Buttons Selector Switches Circuit Breaker Handles PLT Cover Allows for Window ECP Size (W x L) Max. No. of Cover Devices 04 x x 2 04 x x 5 06 x x 3 06 x x 4 08 x x 3 08 x x 3 08 x x 4 10 x x 3 12 x x 4 12 x x 4 14 x x 5 16 x x 6 16 x x 6 18 x x 6 24 x x 9 24 x x 9 Device Layout EATON S CROUSE-HINDS BUSINESS 3
4 ECP Features and Benefits Standard Aluminum Hinge Aluminum hinges standard on sizes and larger, and available on sizes through by adding S598. Stainless cover bolts and hinges are available by adding S Stroke-sanded Finish Stroke-sanding creates smooth surface for installation of push button / pilot light operators. Optional epoxy coat finish available for NEMA 4X requirements. Standard Internal Mounting Pads Factory drilled and tapped, internal mounting pads enable the installer to add a mounting plate in the field. Standard on all sizes. 3 4 Bolt-on / Tap-in Mounting Feet Allows for easy fieldreplacement 5 Standard Neoprene Gasket Comes standard in all sizes. in case mounting Provides NEMA 4 rating for feet are damaged or broken. enclosure. Entries Up To 3 In Diameter Factory-machined, drilled and tapped entries up to 3 in diameter. UL / cul certified for field addition of drilled and tapped entries on sides, top, bottom, or back of the enclosure. Optional Aluminum Plate Cover Provides greater surface area for installation of push button / pilot light operators. Allows for installation of windows in plate cover. Strong, durable, non-porous material. 4 EATON S CROUSE-HINDS BUSINESS
5 Enclosure Ordering Information and Dimensions Inside Nominal Dimensions Overall Dimensions Mounting Catalog Number W L D Usable Depth* A B C E F Weight Weight Mounting [LB] [KG] Plate ECP /8 8-11/ /32 6-1/ / MP0406 ECP /8 8-1/2 20-1/2 6-5/ / MP0416 ECP / / /32 6-3/ / MP0608 ECP / / /32 8-3/ / MP0608 ECP /8 10-1/2 16-1/2 6-3/ / MP0612 ECP / / /32 8-7/ / MP0808 ECP / / /32 8-9/ / MP0810 ECP /8 12-1/2 16-1/2 6-3/ / MP0812 ECP / / /2 8-9/ / MP0812 ECP /8 12-1/2 16-1/2 10-3/ / MP0812 ECP / / /32 8-9/ / MP1010 ECP / / / / / MP1010 ECP / / / / / MP1014 ECP / / /64 7-3/ / MP1212 ECP / /32 9-1/ / MP1212 ECP / / / / MP1212 ECP / /8 23-1/8 8-31/ / MP1218 ECP / /8 23-1/8 11-1/ / MP1218 ECP / /4 29-1/4 11-5/ / MP1224 ECP / /4 29-1/4 13-5/ / MP1224 ECP / / / / MP1236 ECP /8 18-7/8 9-3/ / MP1414 ECP /8 18-7/8 11-3/ / MP1414 ECP /8 18-7/8 13-3/ / MP1414 ECP / / / / / MP1616 ECP / / / / / MP1616 ECP /8 20-7/8 28-7/ / MP1624 ECP /8 22-7/8 22-7/8 10-7/ / MP1818 ECP /4 22-7/8 22-7/8 12-7/ / MP1818 ECP / /8 22-7/8 14-7/ / MP1818 ECP / / / / / MP1824 ECP / / / / / MP1824 ECP / / MP1830 ECP / / / / / MP1836 ECP / / / / / MP1836 ECP / / / / / MP2424 ECP / / / / / MP2424 ECP / / MP2430 ECP / / / / / MP2436 ECP / / / / MP2436 *Usable depth is reduced by 1/2 when adding a mounting plate. ECP Series Enclosures are furnished with or without drilled and tapped openings. Drilling and tapping of conduit openings and device openings in the cover and body are subject to the limitations of maximum size and number of openings as well as spacings. All machining must be done prior to installation. Drilling and Tapping for Entries The location, quantity, and maximum sizes must be in accordance with the following tables: Drilled and Tapped Conduit Openings Minimum Center-to-Center Distance (In.) Conduit Size 1/2 3/ /4 1-1/ /2 3 1/2 1-1/2 3/4 1-5/8 1-3/ /4 1-7/ / /8 2-1/4 2-1/2 1-1/2 2-1/8 2-1/4 2-3/8 2-5/8 2-3/ /8 2-1/2 2-5/8 2-7/ /4 2-1/2 2-3/4 2-7/8 3-1/8 3-1/4 3-3/8 3-5/8 3-7/ /8 3-1/4 3-3/8 3-1/2 3-5/ /4 4-5/8 Minimum clearance for unions only. Metric Equivalents NPT Conduit Size Metric Opening 1/2 M16 X 1.5 3/4 M20 X M25 X /4 M32 X /2 M40 X M50 X /2 M63 X M75 X 1.5 EATON S CROUSE-HINDS BUSINESS 5
6 Defined Area Dimensions - Sidewall and Backwall The number of entries is limited by the total removed area of the entries. To calculate, add up all individual entry areas and cross-check with the total removed area allowed in the tables below. Defined Area - Sidewall Defined Area - Backwall Catalog Number A B C X Y Z L M ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP N/A N/A ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP Total Removed Area Per Enclosure Allowed Allowable Area to Remove Long Short Catalog Side Side Back Number Inch 2 Inch 2 Inch 2 ECP N/A ECP N/A ECP N/A ECP N/A ECP N/A ECP N/A ECP N/A ECP N/A ECP N/A ECP N/A ECP N/A ECP N/A ECP N/A ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP ECP X Y Top and Bottom (Long Side) Defined Area Removed Area Per Threaded Entry Size Minimum Surface Area Removed - (Inch 2 ) Conduit Size 1 Hole 2 Holes 3 Holes 4 Holes 1/ / / / / Defined Area Z X Sides (Short Side) 6 EATON S CROUSE-HINDS BUSINESS
7 Defined Area Dimensions and Removal Rules - Cover The number of entries is limited by the total removed area of the entries. To calculate, add up all individual entry areas and cross-check with the total removed area allowed in the tables below. Catalog Number Cover Style Defined Area - Cover Mounting Feet A B ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Rounded Bolt-on ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in ECP Square Tap-in Surface Area Removed Per Threaded Operator (In 2 ) Thread Size and Type Area Removed Per Device 3/4-14 NPSM /4-20 NEF /8-20 NEF /8-18 UNF Example: A quantity of 22, 3/4-14 NPSM devices would utilize inches 2, meaning the ECP1212 would not accommodate this number of operators. Allowable Area to Remove - Cover (In 2 ) ROUNDED SQUARE 3D Models Available! 3D models for ECP enclosures are now available online for direct integration into your design software. EATON S CROUSE-HINDS BUSINESS 7
ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.
ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical
More informationXCE: Explosionproof Control Enclosures
XCE SERIES XCE: Explosionproof Control Enclosures FEATURES 64 standard sizes available Pre-drilled for hinges (hinges optional) Pre-drilled for sub-panel (sub-panel optional) One-piece, NEMA 4 water-tight
More informationEffective September, 2005 Copyright 2005 PAGE
-42 DTX Junction Boxes: Dust-Ignitionproof, Watertight Cast iron box and cover for surface mounting. Cast aluminum box and cover for surface mounting. Applications DTX dust tight and watertight boxes are
More informationDie Cast Aluminum Conduit Outlet Bodies, Covers & Gaskets
Covers & s die cast copper-free aluminum conduit bodies, covers and gaskets are available for use with rigid or EMT conduit (with set screw). Conduit bodies are available in trade sizes /2 to 4, in the
More informationSingle-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA
62-10 Single-Phase Pad-Mounted Distribution Catolog Transformers Section Howard Industries, Inc. Certifi ed to ISO 9001:2015 62-10 Single-Phase Pad-Mounted Distribution Transformers 5-500 KVA 10002179
More informationIECEx Certificate of Conformity Annexe
for Certificate No.: IECEx TSA 09.004X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment
More informationNominal Wall Thickness Steel Only in. (mm) Outside Diameter With PVC in. (mm)
PVC-Coated Conduit The ultimate in corrosion protection! OCAL-BLUE Conduit Hot-dip galvanized steel or aluminum conduit. Nominal.00 ( mils) blue urethane coating on interior. Hot-dipped galvanized threads
More informationGalvanized Rigid Conduit
Galvanized Rigid Conduit Conforms To: C80.1 - UL 6 ANSI C-80.1 UL Min. WGT. Per 100 Feet in LBS. INCL. CP. O.D. I.D. Thickness Threads Per Inch Feet Per Lift Color Code Thread Protector 1/2" 79.840.632.104
More informationFoundation Products. Poured In Ground Anchor Bolts E1 - E4. Structural Foundations E5 - E12. Copyright 2016 s Industry Inc. SIE-RA-CMP EN
Foundation Products Poured In Ground Anchor Bolts E1 - E4 Structural Foundations E5 - E12 EA EB Poured in Ground Anchor Bolts Layout SIEMENS Anchor Bolts 131702-4X shown for reference purposes only! Actual
More informationVertical and Horizontal Bladder Tanks
DATA SHEET Vertical and Horizontal Tanks Application The ANSUL bladder tank is one component in a balanced pressure proportioning system. Its operation requires no external power other than a pressurized
More informationFIK In-Tank Filters FIK. Max Flow: 170 gpm (643 lpm) Working Pressures to: Rated Static Burst to: Flow Range to:
LOW PRESSURE FILTERS Max Flow: gpm ( lpm) In-Tank Filters Working Pressures to: Rated Static Burst to: psi kpa bar psi kpa bar Flow Range to: gpm lpm Features STYLE C STYLE D STYLE E in-tank filters are
More informationVG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators
VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 1, 01 VGG VGD0 VGD0 Description Only when assembled to Series SKP actuators
More informationDEADBOLT SETS, MECHANICAL FEATURES
, MECHANICAL FEATURES 8000 SERIES LOW PROFILE CYLINDER DEADBOLT FOR 1 5 8 (41mm) DOOR PREP All deadbolts feature a ½ low-profile cylinder projection. CASE: Deadbolt case is formed of heavy gauge steel
More informationSV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT. SV/614 Series SV-DLE/614 Series
SV - Safety Shutoff Valve with Proof of Closure 1/2" NPT - 2" NPT SV/614 Series SV-DLE/614 Series Normally closed automatic shutoff valve with proof of closure and the following approvals. CSA Certified
More informationCUSTOM ENCLOSURE CUTOUTS
www.factorymation.com/enclosures ENCLOSURES 147 WWW.FACTORYMATION.COM/ENCLO- CUSTOM ENCLOSURE CUTOUTS We ll cut the holes to your specifications so the enclosure arrives... READY FOR YOUR ASSEMBLY! Enclosure
More informationTapped Hole (.375) Tapped hole 15 (.594) (.391±.004) Frame 19±0.2 (.750±.008) 12.7±0.2 (.500±.008) 19±0.2 (.750±.008) R S 4 x Ø 5.4 (.
434 Lift-off In-line Zinc can also be 31.5 19.1 (.750) For Lift-Off For on Lift-Off 1300 (300 lbf) 2200 (500 lbf) 56 T.P.I. (2.21) 31.5 19.1 (.750) Tapped hole Ø 9.5 (.375) ultimate 3300 (750 lbf) 9300
More informationVG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators
VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP
More informationMUELLER. A Wall Type. Indicator Post. Reliable Connections. General Information 2. Technical Data/ Dimensions 3. Installation 4-5.
Installation Instructions manual MUELLER table of contents PAGE A-20814 Wall Type General Information 2 Technical Data/ Dimensions Installation 4-5 Maintenance 6 Parts 7 Indicator Post! WARNING: 1. Read
More informationEPOXY FITTINGS DIMENSIONS
Bulletin No. A150 May 1, 2004 EPOXY FITTINGS DIMENSIONS 2"-16" GREEN THREAD fittings may be used with GREEN THREAD and RED THREAD II piping. Refer to Chemical Resistance Guide, Bulletin No. E5615, for
More informationTapped exhaust port. Sturdy, simple, reliable design. Easy to add on Feedback. High gain pilot valve. Simple calibration, external zero adjustment
Electropneumatic Positioner Sturdy, simple, reliable design High gain pilot valve Built in gauge ports Tapped exhaust port Easy to add on Feedback Unit F5 Simple calibration, external zero adjustment Bright
More informationHYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6
INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6 QUALITY SYSTEM ISO:9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)
More informationCheck Valves. Pilot Operated Check Valves. Vickers. 4CG-10, 20 Series 4CS-03, 20 Series 4CT-06/10, 20 Series. Basic Characteristics.
Vickers heck Valves Operated heck Valves 4G-10, 20 Series, 20 Series 4T-06/10, 20 Series Typical Section 4T1-06-D*-20-U, illustrating external drain and decompression features asic haracteristics Maximum
More informationStandard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT
NOR-LAKE, INCORPORATED 800-955-5253 727 Second Street 715-386-2323 P.O. Box 248 866-961-5253 Parts Hudson, Wisconsin 54016 800-388-5253 Service 715-386-4290 FAX www.norlake.com Kold locker WalK-Ins Standard
More informationSpeciÞcations. Engine Dimensions Dimensions in millimeters. Inch equivalents shown in [].
SpeciÞcations Engine Dimensions Dimensions in millimeters. Inch equivalents shown in []. Ê ßÔ Ê ÛÝ Ñ Ê Û ÎÊ Û É 5 ENGINE IDENTIFICATION NUMBERS Kohler engine identiþcation numbers (model, speciþcation
More informationGAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS
GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS CONTINENTAL INDUSTRIES, INC. The Ultimate Connection CONTINENTAL INDUSTRIES, INC. ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, Inc.,
More informationPipe Thread Connection 1/2 inch NPT. Friction Loss Refer to Figure 3
Worldwide Contacts www.tyco-fire.com Model B-1 Pipe Line Strainer General Description The Model B-1 Pipe Line Strainers (Ref. Figures 1 and 2) are designed for installation in the water supply connection
More informationDifferential pressure switch / Lube oil protection control MP 54 and MP 55
Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors
More informationLighting Contactors. 4.1 UL Rated AC Contactors
Electrically Held Lighting Contactors.1 Product Description....................................... Application Description.................................... Standards and Certifications................................
More informationWARNING Δ! WARNING PB-14 SUPERSEDES PB-10. Copyright 2014 by Duct-O-Wire Co PRINTED IN U.SA.
Δ! WARNING Δ! WARNING FOR STOP-SWITCH/EMERGENCY-STOP AND FAILSAFE CIRCUIT REQUIREMENTS, REFER TO OSHA 29 CFR, 1910.6 AND CMAA SPECIFICATIONS 70 AND 74. PB-14 SUPERSEDES PB-10 c Copyright 2014 by Duct-O-Wire
More informationWHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual
WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE
More informationHorizontal Bladder Tanks
DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationBUTTERFLY VALVES. Toll Free (877) - ICFLUID -2-
BUTTERFLY VALVES 1. General HyrdoWer is a globally recognized manufacturer of power unit accessories. They have become specialists in the design of Butterfly Valves and Hydraulic Compensators. The shut
More informationJ21K Series DIFFERENTIAL PRESSURE SWITCH. features
DIFFERENTIAL PRESSURE SWITCH J21K Series features Sealed Metal Bellows Sensors Welded 316 Stainless Steel Sensors Gasketed Die-Cast Aluminum Enclosure with Epoxy Coating Single Switch Output Adjustable
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationVertical Bladder Tanks
DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationAutocalibration Systems For In Situ Oxygen Analyzers
Product Data Sheet PDS 106-340AC SPS 4000, IMPS 4000, and MPS 3000 January, 1999 Autocalibration Systems For In Situ Oxygen Analyzers Cost-effective autocalibration systems for installations ranging from
More informationDual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationOUTER RACE SHIM SPACERS METRIC OUTER RACE SHIM SPACERS. All Dimensions in Millimeters. Material:300 Series Stainless Steel
OUTER RACE SHIM SPACERS Material:300 Series Stainless Steel METRIC OUTER RACE SHIM SPACERS All Dimensions in Millimeters Material:300 Series Stainless Steel 6-16 INNER RACE SHAFT SPACERS 3 /32" To 1 /2"
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationWELL COMPLETION & PROTECTION. www. .com MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD
WELL COMPLETION & PROTECTION MINERAL EXPLORATION ENVIRONMENTAL GEOTECHNICAL GEOTHERMAL ROTARY SONIC HDD www..com WELL COMPLETION & PROTECTION TABLE OF CONTENTS TABLE OF CONTENTS (FLUSHMOUNTS)... 2-5 MONITORING
More informationNorth American Orifice Metering System
Combustion North American Orifice Metering System 8697 and M8697 Metering Orifices accurately measure gas flows to industrial burners. They are compact, inexpensive, and can be installed in individual
More informationSKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Technical Instructions Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25
More informationNO LAKE. Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT
NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 dinecompany.com 800-955-5253 715-386-2323 800-388-5253 Parts 715-386-4291 FAX www.norlake.com NO LAKE KOLD LOCKER WALK-INS
More informationNOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016
NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-6149 FAX www.norlake.com Kold Locker Walk-ins Standard Model Coolers
More informationD. ACCESSORIES ADAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANDLES & LIFT CORDS GALVANIC PROTECTION KITS MUSHROOM STRAINER
. ACCESSORIES AAPTER KITS IMPELLER & SEAL INSTALLATION TOOLS CARRYING HANLES & LIFT CORS GALVANIC PROTECTION KITS MUSHROOM STRAINER SLUGE STRAINERS NEMA 4 WATERTIGHT CONTROL & UAL LEVEL CONTROL (Replaces
More informationDual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634
Dual Modular Safety shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.
More informationDiaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860
PROCESS Diaphragm Vacuum Pumps and Compressors with Group C & D Explosion-Proof Motors Types: UN026, UN726, UN035, UN860 Single & Twin-Head Designs OEM Installation Models UN860FTI EX UN726.3STI EX UN726.3FTI
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationModel MTB-ASME Horizontal Bladder Tanks
DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure
More informationModel MTB-ASME Vertical Bladder Tanks
DATA SHEET Model MTB-ASME Vertical Bladder Tanks Features n UL Listed for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure (design pressure)
More informationEvaporator (DX) Freon Applications 1 12 Tons MHF
Evaporator (DX) Freon Applications 1 12 Tons > > Used For small to medium freon applications The Global Leader In Heat Exchange Technology With seven decades of experience and commitment to total client
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationBull s-eye Levels and Screw-On Levels
Bull s-eye Levels and Screw-On Levels Technical information Definition of terms A spirit level is a hollow body filled with a fluid and a gas bubble which is used to check the horizontal position of an
More informationdumont Minute Man Broaches
Catalog K dumont Minute Man Broaches Standard and Special Broaches Keyway Broaches and Sets Internal Hole and Surface Broaches The dumont Company, Greenfield, Massachusetts www.dumont.com The dumont Company
More informationContinental Industries TRANSITION FITTINGS or FAX Visit
Continental Industries TRANSITION FITTINGS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and
More informationWHEATLEY Series 500 Swing Check Valve
Document Number: TC003001-13 Revision: 02 WHEATLEY Series 500 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...5 INSTALLATION AND OPERATION
More informationNOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016
NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-6149 FAX www.norlake.com Kold Locker Walk-ins Standard Model Coolers
More informationMAKE BOLLARD IMPACT RESISTANT PROTECT FOUNDATIONS RE-USE BOLLARD
\\ PROTECT FOUNDATIONS In-ground or surface mount Impact Recovery System protects foundations from damage when bollards are impacted, need replacing or upgrading. Surface mount version uses Impact resistant
More informationSub-Base Assembly For Type-ML 32 & VR-1 Step Voltage Regulator Single-Phase Liquid-Filled Part # GEK 35171
Transformer Business Department Regulator & Inductive Products Sub-Base Assembly For Type-ML 32 & VR-1 Step Voltage Regulator Single-Phase Liquid-Filled Part # GEK 35171 Last Update 11-19-2013 Tom Dauzat,
More informationINSTRUCTIONS 360 Y-DROP HAGIE STS 2015
INSTRUCTIONS 60 Y-DROP HAGIE STS 05 INSTRUCTIONS 60 Y-DROP HAGIE STS 05 INTRODUCTION Before beginning, it s important to know where each mounting bracket fits relative to the row spacing involved. The
More informationDual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604
Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21
More informationIntroduction. P r otective Seals Panel seal for One Hole Mounting (OHM) O-Ring seals for panel mounting Switch boots
SECTION F Introduction ACCESSORIES Switch Guar d s Prevent accidental operation of switches Switch operation limited to selected functions Adaptable to one, two and four pole config u r a t i o n s One
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationModels EXN and OLG. General Description. Features and Benefits. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations
Models EXN and OLG Certified. Not Modified. Pressurizer for Vertical Air Conditioners Increased Safety for Hazardous Locations General Description Industrial Climate Engineering s (ICE) EXN and OLG pressurization
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationFor Multi-Parameter Meters see mvx
Design Features VORTEX IN-LINE FLOW METERS For Multi-Parameter Meters see m Principles of Operation n No moving parts to wear or fail. n Electronics can be remotely mounted up to 30.5 m (0 ft). n No fluid
More informationDifferential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et
Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING Technical leafl et Contents Page Introduction... 3 Features... 3 Approvals... 3 Materials
More informationSection GATE VALVES
Section 02521 PART 1 GENERAL 1.01 SUMMARY This Section includes the furnishing and installation of gate valves for isolation and dead-end service as shown on Plans and as specified herein. 1.02 MEASUREMENT
More informationENGINE/ PUMP ADAPTERS
ENGINE/ PUMP PTERS Hayes Manufacturing, Inc. Fife Lake, MI 9633 Phone: 23-879-3372 Fax: 23-879-330 TRNSMISSION PROUTS Fife Lake, MI 9633 Phone: 23-879-3372 Fax: 23-879-330 Table Of ontents Engine/ Mount
More informationSLEEVED PLUG VALVES 2-WAY
Specialty Valves 2-WAY ANSI/ASME CLASS 150 LBS Dimensions to ANSI B16.5 & B16.10 1 Six (6) top holes * 2 1/2 valves are made from 3 casting, but flanges are machined to 2 1/2 dimensions 1/2 4.25 108.00
More informationSLEEVED PLUG VALVES 2-WAY
Specialty Valves 2-WAY ANSI/ASME CLASS 150 LBS Dimensions to ANSI B16.5 & B16.10 1 Six (6) top holes * 2 1/2 valves are made from 3 casting, but flanges are machined to 2 1/2 dimensions 1/2 4.25 108.00
More informationPressure Switch for gas and air
Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth
More informationAMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS
AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS DESIGNED TO HOLD THE WEIGHT FOR ELECTRICAL CABLE AS IT HANGS IN VERTICAL, SLOPING OR HORIZONTAL POSITIONS. EASILY INSTALLED AND REMOVED USING NO
More informationBasic & Controlled Atmosphere Glove Boxes
I N T R O D U C T I O N Precise Basic and Controlled Atmosphere Glove Boxes provide a leak-tight environment for work with contamination-sensitive materials. Precise Basic Glove Boxes are simple, economical
More informationVERTICAL TURBINE PUMPS Right Angle Gears. Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts
Peerless Pump Company Indianapolis, IN 46207-7026 VERTICAL TURBINE PUMPS Right Angle Gears SECTION 110 Page 1 January 2, 2007 Shaft Guarding for Horizontal Mounted Spicer Universal Joint Drive Shafts A
More informationHomestead Series 820 AWWA Butterfly Valves
Homestead Series 820 AWWA Butterfly Valves Dependable Valves for Water & Wastewater Service BODY: The ductile iron body meets or exceeds the design strength requirements of the AWWA C504 standards. Flange
More informationHEAVY DUTY PNEUMATIC
HEAVY DUTY PNEUMATIC Series A4 MEDIUM DUTY HYDRAULIC Series H4 PERMANENTLY LUBRICATED HEAVY DUTY PNEUMATIC Series L4 586.778.7680 SERIES A4/L4/H4 39 A4/L4/H4 FEATURES 1 1 9 9 12 8 7 5 12 3 13 4 10 2 11
More informationFord Service Saddles and Tapping Sleeves
Section AA 5/2001 Ford Service Saddles and Tapping Sleeves The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 219/563-3171 FAX: 1-800-826-3487
More informationAWWA C504 COMPLIANT VALVES FROM 3 THRU 108
AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly
More informationASYBCO 90 O ELBOW LONG RADIUS O.D. I.D.
90 O ELBOW LONG RADIUS Standard weight Extra strong Schedule 160 Double extra strong ASTM A-234 ASME / ANSI B16.9 Carbon and ferritic alloy steel Produced from X-rayed, stress-relieve welded pipe. Welds
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure. DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationK16.10 EDGE DOOR HANDLES K16 DOORS
K16 DOORS K16.10 01.03.2018 Waregemstraat 5-9870 Zulte - Belgium - T. +32 9 388 88 81 - F. +32 9 388 88 21 - commercial@sobinco.com - www.sobinco.com CONTENTS 1. General characteristics... K16.10.03 1.1.
More informationMEDICAL EQUIPMENT CATALOG
THE MOST TRUSTED MEDICAL EQUIPMENT IN NORTH AMERICA MEDICAL EQUIPMENT CATALOG Total Components Including Bulk Oxygen Supply, Back up and Delivery Equipment Designs for High Pressure, Liquid or Bulk Applications
More informationNorth American Simplex Basket Strainers for Gas and Oil
Combustion North American Simplex Basket Strainers for Gas and Oil A mesh lining (304 stainless standard or 316 stainless or monel special), either 20, 40 or 100 mesh, can be provided, depending on the
More informationDual Modular Safety Shutoff Valves. DMV-D/11 Series DMV-DLE/11 Series
Dual Modular Safety Shutoff Valves DMV-D/11 Series DMV-DLE/11 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked
More informationPRODUCTS CATALOG
2017-2018 PRODUCTS CATALOG THE BROADEST LINE OF QUALITY ELECTRICAL FITTINGS & TUBULAR PRODUCTS PLUS THE BEST PERFORMANCE GUARANTEE IN THE INDUSTRY ABOUT US Electroline is committed to manufacturing quality
More informationMLS Series Liquid Level Switches. Installation and Operations Manual Section 15
MLS Series Liquid Level Switches Installation and Operations Manual 00-02-0730 2012-11-11 Section 15 In order to consistently bring you the highest quality full featured products, we reserve the right
More information1200 Series Pressure Regulators
SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of
More informationThe Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure
General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal
More information500 SERIES. Standard-Duty Grade 3 Surface Applied Closers. Standard Features. 3 hours fire rated. door openings. closing speeds
500 SERIES Standard-Duty Grade 3 Surface Applied Closers Standard Features n Performance Complies with ANSI A156.4, Grade 3, 500,000 cycles, UL/ULC listed up to 3 hours fire rated n Chassis/Closer Cast
More informationGas Pressure Switch for DMV safety shutoff valves
Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts
More informationPressure Switch for gas and air GGAO-A4
Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes
More informationSafety switch renewal parts
Renewal Parts RP00801001E Supersedes July 2002 Safety switch renewal parts Contents Description Page Heavy-duty switch....2 Line shield....3 Operating mechanism....3 Operating handle....3 Fusible switching
More informationDual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series
Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure DMV-D/604L Series DMV-DLE/604L Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Listed
More informationSuperstrut. Metal Framing. Surface Raceway and Lighting Systems
Material Superstrut electrical raceway, fixture hanging channel, closure strip and accessories are manufactured from hot rolled strip steel. Standard finish for the accessories is GoldGalv. Design Data
More informationPTC INSTRUMENTS 2301 Federal Ave Los Angeles CA Phone: Model 500 Automatic Operating Stand Type 3
The Model 500 automatic operating stand provides constant load, controlled rate-of-descent, and application velocity, through a geared electric motor and braking mechanism that alternately lowers the durometer
More informationNorth American Pressure Switches
Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are
More informationSECTION BUTTERFLY VALVES
SECTION 15112 BUTTERFLY VALVES PART 1 GENERAL 1.01 SUMMARY A. All butterfly valves shall be of the tight closing, rubber seated type and fully comply with the latest revision of AWWA Standard C504, Class
More information