1 Δ! WARNING Δ! WARNING FOR STOP-SWITCH/EMERGENCY-STOP AND FAILSAFE CIRCUIT REQUIREMENTS, REFER TO OSHA 29 CFR, AND CMAA SPECIFICATIONS 70 AND 74. PB-14 SUPERSEDES PB-10 c Copyright 2014 by Duct-O-Wire Co PRINTED IN U.SA.
2
3
4
5 RP Series Pendant Station - Rubber Enclosures One-Speed and Two-Speed Control plus Accessories With Standard Cord Grip RP-4 RP-3 Dimensions and Weights Accommodates Enclosure Dimension-Inches Weight Cable Diameter Size Width Depth Length Lbs. (Inches*) Two-Button 3 2-1/2 5-3/4 1-3/ Four-Button 3 2-1/ / Six-Button 3 2-1/2 12-3/8 3-1/ Eight-Button 3 2-5/8 15-3/4 4-1/ * Specify Cable Diameter when the Cable Used is not within the Range Listed. RPB Series Pushbutton Pendant Stations feature steel reinforced rubber construction with a tongue and groove cover plate to protect buttons from many elements. The RPB Series support a number of applications with single and two speed operation, momentary and maintained switches, and a variety of accessory and replacement parts. Wire mesh grips for added strain relief are available. Nitrile Rubber Construction NEMA 1, 3, 4 and 12 UL Listed and CSA Approved Enclosures Each complete enclosure includes a standard package of legend plates, cord grip and strain relief bracket. RP-1 RP-2 RP-3 RP-4 RP-2 Two-Button Four-Button Six-Button Eight-Button RP-1 Front Covers Only (including Legend Plate Package) RP-1F Two-Button RP-2F Four-Button RP-3F Six-Button RP-4F Eight-Button Pictures are for illustration purposes and may not represent actual product. Duct-O-Wire recommends installation of an Emergency Stop on all Pendants. Duct-O-Wire 5
6 Dimensions and Weights Enclosure Catalog Dimensions - Inches Weight Accommodates Cable Diameter Number Width Depth Length Lbs. (Inches) PSW /8 17-1/2 4-1/
7
8 SINGLE SPEED INSERTS PSW Sq D **NEMA Ref Catalog No. Description - Contacts J L RPB RPS SKYP RATING A SP-1 One Speed-2 N.O. X 2 4X A SP-1-S One Speed-2 N.O. 2 N.C. X 2 4X B RB-1 One Speed-2 N.O. 2 N.C. X 1 4 C PB-1A One Speed-2 N.O. X X 12 C PB-1B One Speed-2 N.O. X 2 X 2 12 D 9001SKRU1 One Speed-2 N.O. X 2 4X PSW Sq D **NEMA Ref Catalog No. Description - Contacts J L RPB RPS SKYP RATING A SP-2 Two Speed-4 N.O. X 2 4X A SP-2-S Two Speed-4 N.O. 4 N.C. X 2 4X B RB-2A Two Speed-2 N.O. X 1 4 D 9001SKRU2 Two Speed-4 N.O. X 2 4X X 1 X 2 = = Requires 2 each per motion Mechanical Interlocking *For Normal 2 Speed Switch Insert use PB-3A and PB-3B and Wire for Two Speed Operation. X 1 X 2 TWO SPEED INSERTS = Requires 2 each per motion = Mechanical Interlocking THREE AND FIVE SPEED INSERTS PSW Sq D **NEMA Ref Catalog No. Description - Contacts J L RPB RPS SKYP RATING A SP-3 Three Speed-6 N.O. 2 N.C. X 2 4X C PB-3A Three Speed-6 N.O. X X 12 C PB-3B Three Speed-6 N.O. X 2 X 2 12 C PB-5A Five Speed-10 N.O. X X 12 C PB-5B Five Speed-10 N.O. X 2 X 2 12 D 9001SKRU3 Three Speed-6 N.O. X 2 4X D 9001SKRU5 Five Speed-10 N.O. X 2 4X X 2 = Mechanical Interlocking
9 MOMENTARY START / STOP INSERTS AND SWITCHES PSW Sq D **NEMA Ref Catalog No. Description-Contacts J L RPB RPS SKYP RATING A SP-A Two Button-1 N.O. 1 N.C. (2 hole) X 4X D LS-MS One Button-1 N.O. (1 hole) X X 4 X X 3 4X D LS-MS-LED-x One Button-1 N.O. "x" = color (1 hole) X X 4 X X 3 4X F LS-H One Button-1 N.O. X 3 X 3 X 3 X 3 12 H K-1A One Button-1 N.O. (1 hole) X 4 J PB-1-S One Button-1 N.O. 1 N.C. (1 hole) X X X 4X C PB-ST Two Button-1 N.O. 1 N.C. (2 hole) X X 12 K PB-STA Two Button-1 N.O. 1 N.C. (1 hole) X 3 X 3 X 3 12 P PB-STB Two Button-1 N.O. 1 N.C. (1 hole) X 3 X 3 X 3 4X Q RPS-MS One Button-1 N.O. X 3 X 3 X 3 1 X 3 X 4 = Accessory area only = Requires Deep Back Enclosure MAINTAINED START / STOP INSERTS AND SWITCHES PSW Sq D **NEMA Ref Catalog No. Description-Contacts J L RPB RPS SKYP RATING A SP-M Two Button-1 N.O. 1 N.C. (2 hole) X 4X D LS-6A One Button-1 N.O. (1 hole) X 3 X 4 X 3 X 3 4X F LS-6A1 One Button-1 N.O. X 3 X 3 X 3 X 3 12 H RPB-6A1 One Button-1 N.O. "x" = color (1 hole) X 4 M PB-STM Two Button-1 N.O. (2 hole) X 3 X 3 X 4X M PB-STM-2 Two Button-1 N.O. (2 hole) X 3 X 3 X 4X K PB-STMA Two Button-1 N.O. 1 N.C. (1 hole) X 3 X 3 X 3 12 P PB-STMB Two Button-1 N.O. 1 N.C. (1 hole) X 3 X 3 X 3 4X X 3 X 4 = Accessory area only = Requires Deep Back Enclosure PSW Sq D **NEMA Ref Catalog No. Description-Contacts J L RPB RPS SKYP RATING T LS-STMM E-Stop-1 N.C. (1 hole) X 3 X 4 X 3 X 3 4X T LS-STMM-A E-Stop-1 N.C. 1 N.O.* (1 hole) X 3 X 4 X 3 X 3 4X W PB-STMM E-Stop-1 N.C. (1 hole) X X X 12 *With Built-in Momentary Start / Stop EMERGENCY STOPS X 3 X 4 = Accessory area only = Requires Deep Back Enclosure
10
11
12
13
14 Basic Figure 8 Systems Heated Conductor Systems Side Contact Systems Totally Enclosed Systems 8-Bar Systems HD-500 HD-1000 HD-1500 Duct-O-Wire 14
15 Duct-O-Wire 15
16 U.S.A W. Second Street Oconomowoc, Wisconsin U.S.A. 345 Adams Circle Corona, California U.S.A. Distributed by Tri-State Equipment Company Inc. Web: PH: FAX:
SBN Pendant Pushbutton Station. Technical Manual. Part Number: R2 January Magnetek Material Handling
SBN Pendant Pushbutton Station Technical Manual Part Number: 126-11176 R2 2016 Magnetek Material Handling Table of Contents Service Contact Information... 3 Preface and Safety... 4 Product Safety Information...
More informationIndustrial Grade Portable Outlet Boxes, Wire Mesh Grips & Coverplates
Product Bulletin Industrial Grade Portable Outlet Boxes, Wire Mesh Grips & Coverplates Portable Electrical Outlet Boxes from Leviton are the perfect solution for creating OSHA and NEC Compliant portable
More informationECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.
ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical
More informationwill not support combustion
Strain Relief Grips Operating Temperatures Material Temperature Range Aluminum 40 C to +149 C ( 40 F to +300 F) Aluminum deluxe cord grips 34 C to +115 C ( 30 F to +240 F) Non-metallic deluxe cord grips
More informationAMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS
AMTEC SUPPORT GRIPS STANDARD, HEAVY DUTY & CONDUIT GRIPS DESIGNED TO HOLD THE WEIGHT FOR ELECTRICAL CABLE AS IT HANGS IN VERTICAL, SLOPING OR HORIZONTAL POSITIONS. EASILY INSTALLED AND REMOVED USING NO
More informationPushbuttons, Indicating Light, and Rotary Switch Stations Series 4975
Series 4975 Series 4975 Pushbutton Stations are designed for shipboard control applications requiring heavy duty watertight master switches. Stations are available with one, two or three elements equipped
More informationF series Foot Switches
F series Foot Switches ITC presents a complete line of foot switches from Bernstein, designed to respond to the most stringent requirements for machine control and safety applications. The F series includes
More informationCUSTOM ENCLOSURE CUTOUTS
www.factorymation.com/enclosures ENCLOSURES 147 WWW.FACTORYMATION.COM/ENCLO- CUSTOM ENCLOSURE CUTOUTS We ll cut the holes to your specifications so the enclosure arrives... READY FOR YOUR ASSEMBLY! Enclosure
More informationJunction Boxes Series 8118
> Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature
More informationProduct Specifications Specialty Junction Boxes
NOVA Energy & Automation Product Specifications Specialty Junction Boxes Model JB 03 January 2012 Product Description 1. Specialty Junction Boxes Nova Junction Boxes are custom manufactured by size, material,
More informationOEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE
OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right
More informationECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.
ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical
More informationSI-F971A. 9-speed super narrow chain such as CN-7700 / CN-HG92 8- / 7- / 6-speed narrow chain such as CN-HG50 / CN-IG51
SERVICE INSTRUCTIONS SI-F971A Front Drive System Before use, read these instructions carefully, and follow them for correct use. WARNING Use neutral detergent to clean the chain. Do not use alkali-based
More informationTECHNICAL INFORMATION
TECHNICAL INFORMATION Model No. Description RP2300FC, RP2301FC Router CONCEPT AND MAIN APPLICATIONS Models RP2300FC and RP2301FC are upgraded sister tools of our current plunge-type electronic router Model
More informationSingle-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA
62-10 Single-Phase Pad-Mounted Distribution Catolog Transformers Section Howard Industries, Inc. Certifi ed to ISO 9001:2015 62-10 Single-Phase Pad-Mounted Distribution Transformers 5-500 KVA 10002179
More informationReferences 6 k thermal overload relays, adjustable from 0.11 to 16 A
s 6 k thermal overload relays, adjustable from 0.11 to 16 A 3-pole relays with screw clamp terminals These overload relays are designed for the protection of motors. They are compensated and phase failure
More informationNCR SelfServ 38 ATM. Site Preparation B D
TM NCR SelfServ 38 ATM Site Preparation B006-6592-D000 0909 ATM DIMENSIONS ATM without Air Conditioning Unit The illustration below shows the dimensions for an ATM without the optional air conditioning
More informationenclosed product catalogue 2010 isolating switches main/emergency off switches changeover switches insulated stainless steel mild steel
enclosed product catalogue 2010 isolating switches main/emergency off switches changeover switches insulated stainless steel mild steel kraus & Naimer enclosed switch catalogue Contents This catalogue
More informationDescriptions INCLUDES (2) 1500WC WIRE CLIP; WITH 1/2 INCH, 3/4 INCH CONCENTRIC KNOCKOUT ON BASE
3804 South Street 75964-7263, TX acogdoches Phone: 936-569-7941 Fax: 936-560-4685 1542D STL Junction Box 1500 Wiremold/Legrand Catalog umber Manufacturer Description Weight per unit Product Category Features
More informationA28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure
Master Catalog 125 Temperature Controls Section A Product Bulletin A28 Issue Date 0618 A28 Series Two-Stage Temperature Controls with NEMA 1 Enclosure Application These two-stage controls are designed
More informationConductor Bushings Series 8174
> Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The
More informationTECHNICAL DATA. Trimpac 257a. September 16, 2013
September 16, 2013 Trimpac 257a 1. DESCrIpTION DESCRIPTION The Viking Double SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-2 and D-2B used with either a Model E or F Deluge Valve (A.1), a Viking
More informationenclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)
enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) Stainless steel and plastic enclosures for use in potentially explosive environments R Rittal system partners Perfect
More informationTECHNICAL DATA. Trimpac 256a. October 31, 2013
October 31, 2013 Trimpac 256a 1. DESCRIPTION The Viking SUREFIRE SIngle Interlock Preaction TRIMPAC Model D-1 and D- 1B used with either a Model E or F Deluge Valve (A.1), a Viking Easy Riser check valve
More informationLifeJacket saves lives when hydraulic pressure fails
Adams Safety Products LifeJacket Hydro Safety LifeJacket saves lives when hydraulic pressure fails Proactive safety solution stands guard 24 hours a day Detects sudden loss of hydraulic pressure Locks
More informationRear Drive System SERVICE INSTRUCTION. Specifications SI-R670B
- SERVICE INSTRUCTION SI-R670B t Rear Drive System Before use, read these instructions carefully, and follow them for correct use. In order to realize the best performance, we recommend that the following
More informationSocket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11
Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double
More informationXCE: Explosionproof Control Enclosures
XCE SERIES XCE: Explosionproof Control Enclosures FEATURES 64 standard sizes available Pre-drilled for hinges (hinges optional) Pre-drilled for sub-panel (sub-panel optional) One-piece, NEMA 4 water-tight
More informationPosition switches FP series
A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever
More informationMaxSB - Low Voltage Switchboard
BU 3101 Low Voltage Systems, March 2009 Low Voltage Systems MaxSB - Low Voltage Switchboard May 5, 2009 Slide 1 MaxSB Product Overview Description Value Rated Main bus current 1600A, 2000A, 3000A, 3200A,
More informationDual Modular Safety Shutoff Valve with NEMA 4x Enclosure. DMV-D/604L Series DMV-DLE/604L Series
Dual Modular Safety Shutoff Valve with NEMA 4x Enclosure DMV-D/604L Series DMV-DLE/604L Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Listed
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationenclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)
lri030784900.eps lri031083400.eps enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) fri040466500.eps Stainless steel and plastic enclosures for use in potentially explosive
More informationIntroduction. Description. Series P48 Pressure Controls for Steam, Air or (hot) Water. Feature and Benefits
PSC9626 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin Series Pressure Controls for Steam, Air or (hot) Water Introduction The series pressure controls are designed as operating
More informationDifferential pressure switch / Lube oil protection control MP 54 and MP 55
Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors
More informationInfrared Linescanners
Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories
More informationPuller. Operation Service Parts SHERMAN & REILLY, INC.
Puller Operation Service Parts SHERMAN & REILLY, INC. P.O. Box 11267 400 West 33rd Street Chattanooga, TN 37401 USA Phone 423 756 5300 Fax No. 423 756 2948 Toll-Free 800 251 7780 Web Site www.sherman-reilly.com
More informationZelio Relays RSL Slim Interface Plug-In Relays
Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3
More informationDifferential pressure controls, Type MP 54, 55 and 55A
MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors
More informationCORPORATE SAFETY MANUAL
CORPORATE SAFETY MANUAL Procedure No. 32-0 Revision: Date: May 2005 Total Pages: 10 PURPOSE To provide general guidelines for the inspection of all ropes, chains, cables, slings, etc. used for personnel
More informationB104ZN BLTD 4H 90 L Bracket. Features. Material, Color, and Finish. Dimensions and Weight. Long Description
B104 BLTD 4H 90 L Bracket Cooper B-Line/Cable Tray Catalog Number Manufacturer Description Weight per unit Product Category Features Material Material, Color, and Finish Finish Dimensions and Weight Size
More informationREMKE STYLE PowR-TECK CONNECTORS
REMKE STYLE PowR-TECK CONNECTORS CONNECTORS FOR JACKETED TECK CABLE Your LEAD BRAND in the changing market EXPERIENCE THE POWR OF A ONE PIECE DESIGN COMPRESSION RING Downward pressure ensures uniform compression
More informationDual Modular Safety Shutoff Valves. DMV-D/602 Series DMV-DLE/602 Series
Dual Modular Safety Shutoff Valves DMV-D/602 Series DMV-DLE/602 Series Two normally closed safety shutoff valves in one housing; each with the following approvals. UL Recognized UL 429 File # MH16727 CSA
More informationDual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604
Dual Modular Safety Shutoff Valves with NEMA 4x Enclosure DMV-D 704/604 DMV-DLE 704/604 Two normally closed safety shutoff valves in one housing; each with the following approval. CSA Certified ANSI Z21.21
More informationSPEED SHORE MANUFACTURER S TABULATED DATA "MHS" MODELS. STEEL MANHOLE SHIELDS 4 Single Wall 4 Double Wall 4 Double Wall with Cut-Outs
SPEED SHORE MANUFACTURER S TABULATED DATA "MHS" MODELS STEEL MANHOLE SHIELDS 4 Single Wall 4 Double Wall 4 Double Wall with Cut-Outs January 01, 2005 3330 S. SAM HOUSTON PKWY E. HOUSTON, TEXAS 77047 Tel:
More informationDual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series
Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof
More informationFoundation Products. Poured In Ground Anchor Bolts E1 - E4. Structural Foundations E5 - E12. Copyright 2016 s Industry Inc. SIE-RA-CMP EN
Foundation Products Poured In Ground Anchor Bolts E1 - E4 Structural Foundations E5 - E12 EA EB Poured in Ground Anchor Bolts Layout SIEMENS Anchor Bolts 131702-4X shown for reference purposes only! Actual
More informationSwimming Pool Requirements
Swimming Pool Requirements 8040 S. 6th Street Oak Creek, WI 53154 (414) 766-7000 www.oakcreekwi.org Revised: August 8. 2017 PERMITS A permit from the Inspection Department is required prior to putting
More informationDual Modular Safety Shutoff Valves with Proof of Closure. DMV-D/622 Series DMV-DLE/622 Series
Dual Modular Safety Shutoff Valves with Proof of Closure DMV-D/622 Series DMV-DLE/622 Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof of closure. Each
More informationPool / Hot Tub Permit
Application Date: Pool / Hot Tub Permit Lower Southampton Township 1500 Desire Avenue, Feasterville, Pa 19053 215-357-7300 Permit Number: Permit Fee: Fee includes required fencing permit and bonding fee.
More informationE3F2 Series DC Cylindrical M18 Photoelectric Sensors to be Discontinued March 2014; Replace with E3FA or E3FB
NO: PH-177 PRODUCT: E3F2 DC Photoelectric Sensors DATE: May 2013 TYPE: Partial Discontinuation Notice E3F2 Series DC Cylindrical M18 Photoelectric Sensors to be Discontinued March 2014; Replace with E3FA
More informationCheck with local zoning official for property line distance requirements.
RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More informationMartin V-Plow HD. Go to Martin V-Plow HD web page. Operator s Manual M3201
Martin V-Plow HD Go to Martin V-Plow HD web page Operator s Manual M3201 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION OF THE MATERIAL; USER S FAILURE TO
More informationOEM Manual. MODEL ½ Digit DRUM SCALE
OEM Manual MODEL 4020-3 ½ Digit DRUM SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA & Canada) Phone:
More informationDual Modular Safety Shutoff Valves with Two-stage operation. DMV-ZRD/602 Series DMV-ZRDLE/602 Series
Dual Modular Safety Shutoff Valves with Two-stage operation DMV-ZRD/602 Series DMV-ZRDLE/602 Series Two normally closed automatic shutoff valves in one housing; each with the following approvals. UL Recognized
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI
Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More informationDESIGN ENVELOPE 6800 G 1 DUTY PUMP
DESIGN ENVELOPE 68 G 1 DUTY PUMP AND 1 STANDBY, DOMESTIC WATER BOOSTER WIT STANDBY N122s N192s SUBMITTAL File No: 1.615 Date: june 27, 217 Supersedes: new Date: new Job: Representative: Engineer: Contractor:
More informationNorth American Pressure Switches
Combustion North American Pressure Switches Bulletin 8757 Pressure switches are used with Automatic Shutoff Valves or Solenoid Valves to interrupt fuel flow in the event of fuel or air failure. They are
More informationSTANDARD TYPE 1 ENCLOSURE WITH KEYED LOCK
STANDARD TYPE 1 ENCLOSURE WITH KEYED LOCK Industry Standards UL 50, Type 1 Nema Type 1 UL File E235575 X BUTT HINGES H 1/4 TURN LATCH 1-3/8" KNOCKOUT ON ALL SIDES W PANEL (ORDER SEPARATELY) STIFFENER DETAIL
More informationINSTRUCTION MANUAL. January 23, 2003, Revision 0
INSTRUCTION MANUAL Model 810A In-Vitro Test Apparatus for 310B Muscle Lever January 23, 2003, Revision 0 Copyright 2003 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora,
More informationCABLE GLANDS. Connector~Tech Providing Harsh Environment Connector SOLUTIONS
Connector~Tech www.connectortech.com.au Providing arsh Environment Connector SOLUTIONS CABLE ANDS Connector~Tech is a Division of: Colourview Electronics (QLD) Pty Ltd (ABN 99 065 191 424) Unit 2, 8 Colebard
More informationValves, manually operated
Valves, manually operated Valves, manually operated Key features VHEM-P K/O-3-PK-3 H-3-¼-B KH/O-3-PK3 TH/O-3-PK3 F-3-¼-B Innovative Versatile Reliable Easy to mount Small and compact for a wide range of
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationAnchors that can be used for a lifeline in a grain bin. or Ladder do not make good anchors!
Anchors that can be used for a lifeline in a grain bin. or Ladder do not make good anchors! Definitions: Carabiner 1 Webbing attachment hardware with double locking action rated at 4,000 pounds 8 mm Accessory
More informationDifferential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING. Technical leafl et
Differential pressure controls/ Lube oil protection controls MP 54 and MP 55 REFRIGERATION AND AIR CONDITIONING Technical leafl et Contents Page Introduction... 3 Features... 3 Approvals... 3 Materials
More informationGT21 String Trimmer UT Page 1 of 16 Accessories
GT21 String Trimmer UT-26038 Page 1 of 16 Accessories GT21 String Trimmer UT-26038 Page 2 of 16 Accessories Ref # Part Number Qty S/P/F Description 1 PS01443 1 TOOL KIT 2 DG07819 1 /P STRAP 3 G07830 1
More informationSEAL Enclosure Installation Instructions
SEL Enclosure Installation Instructions WeRackYourWorld.com 1-866-TRY-GLCC (879-4522) PREFCE This manual is provided to prevent service personnel from committing an act that results in the risk of fire,
More informationValves, manually operated
Valves, manually operated Valves, manually operated Key features VHEM-P K/O-3-PK-3 H-3-¼-B KH/O-3-PK3 TH/O-3-PK3 VHEM-L F-3-¼-B Innovative Versatile Reliable Easy to mount Small and compact for a wide
More informationSWIMMING POOL REQUIREMENTS
PERMITS A permit from the Inspection Department is required prior to putting up a permanent pool. A permit is required for permanent pools, such as the following: SWIMMING POOL REQUIREMENTS The pool is
More informationDifferential pressure switch MP 54, MP 55 and MP 55A
Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating
More informationSPECIFICATIONS ATTENTION
VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane
More informationRESIDENTIAL SWIMMING POOL
MAIL PICK-UP A. SWIMMING POOL PERMIT TYPE ABOVE-GROUND POOL B. IDENTIFICATION PROJECT LOCATION (ADDRESS): NORTH WHITEHALL TOWNSHIP 3256 LEVANS ROAD, COPLAY, PA 18037 610-799-3411 610-799-9629 FAX www.northwhitehall.org
More informationIndustrial Grade Portable Outlet Boxes and Coverplates
Product Bulletin for Portable Outlet Boxes Industrial Grade Portable Outlet Boxes and Coverplates Leviton s line of temporary power solutions now includes industrial grade portable outlet boxes and coverplates.
More informationDual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11
Dual Modular Safety Shutoff Valves DMV-D 525/11 DMV-DLE 525/11 Two normally closed safety shutoff valves in one housing; each with the following approvals. CSA Certified ANSI Z21.21 CSA 6.5 Marked C/I
More informationOriginal Date of Issue: 04/09
POLICIES AND PROCEDURES DEPARTMENT: Environmental Health and Safety SUBJECT: Electrical Safety Program Original Date of Issue: 04/09 Reviewed 12/2011 Revised 12/2011 BACKGROUND ELECTRIC SHOCK It is well
More informationXMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type
Characteristics pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Main Range of product Pressure sensor type Pressure sensor name Pressure sensor size OsiSense XM Electromechanical
More information(1) Minimum Required. At least one entrance of sufficient area shall be provided to
(B) Clear Spaces. Working space required by this section shall not be used for storage. When normally enclosed live parts are exposed for inspection or servicing, the working space, if in a passageway
More informationSecurity and confidence at height.
A Security and confidence at height. Vertical Systems DISTRIBUTED BY M DBI-SALA Vertical Systems are designed to complement your ability to work while meeting all applicable OSHA and ANSI standards. Vertical
More informationPVC Electrical Fittings & Accessories Price List
PVC Electrical Fittings & Accessories Price List Effective August 26, 2002 Electrical Products PVC Electrical Fittings & Accessories Price List PVC Electrical Standards 2 Schedule 40 Fittings: Couplings,
More informationTechnical Data. Dimensions
0102 Model Number Features Comfort series 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories BF 18 Mounting flange, 18 mm EXG-18 Quick mounting bracket with dead stop Technical Data specifications
More informationRIX COMPRESSORS. MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230. November 21, 2002 APPLICABILITY [ A]
RIX COMPRESSORS MICROBOOST Owner s Manual CONFIGURATION A MB-115 MB-230 November 21, 2002 APPLICABILITY [ A] INTRODUCTION Safety This electromechanical equipment is designed to produce high pressure gas.
More informationGT22 Trimmer/Brushcutter UT Page 1 of 16 Accessories
GT22 Trimmer/Brushcutter UT-26039 Page 1 of 16 Accessories GT22 Trimmer/Brushcutter UT-26039 Page 2 of 16 Accessories Ref # Part Number Qty S/P/F Description 1 UP00578 1 TOOL KIT 2 DG07819 1 /P STRAP 3
More information1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition
Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure
More information3M Telecommunications Solutions for Networks. Quante QSA (= LSA plus) System Catalogue. Innovation
3M Telecommunications Solutions for Networks Quante QSA (= LSA plus) System Catalogue Innovation IDC Modules Overview 3M Quante Cross Connect System QSA QSA Series 1 Connection modules for screw fixing
More informationBulletin Swimming pool, hot tub and spa installations Rules , , , , , and
Bulletin 68-7-11 Swimming pool, hot tub and spa installations Rules 68-000, 68-056, 68-058, 68-064, 68-068, 68-302 and 68-404 Scope (1) Swimming pools - general (2) Grounding & bonding (a) Bonding for
More informationibridge and ibridge Ultra
2.00 mm Board to Cable Connectors ED. 06 10.2016 Catalog EA IB001 erni.com erni.cn TABLE OF CONTENTS OVERVIEW General 03 Technical Details 04 Features 05 Electrical and Mechanical Characteristics 10 Ordering
More informationAutoDrill s OUTSTANDING FEATURES
PRODUCTION DRILLING & TAPPING SOLUTIONS Reduce Your Costs and Increase Your Production The Affordable, Powerful, Compact Solution AutoDrill s OUTSTANDING FEATURES Self Feeding with Air or Oil Thrust Capacity
More informationReferences, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)
References, characteristics Electromechanical pressure switches For power circuits, type XMP. IP degree of protection Size (87 psi). Adjustable differential, for regulation between thresholds Switches
More informationDual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series
Dual Modular Safety Shutoff Valves with Two-stage operation and Proof of Closure DMV-ZRD/612 Series DMV-ZRDLE/612 Series Two normally closed automatic shutoff valves in one housing. Valve 1 (V1) incorporates
More informationSunbrite LTC Large Underwater Pool Lights
Sunbrite LTC Large Underwater Pool Lights O W N E R S M A N U A L 3050 0997 ASB INSTALLATION, OPERATION & PARTS This manual should be furnished to the end user of this light; its use will reduce service
More informationRTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.
Introduction RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class. The regulator is used for reducing and regulating the pressure of natural gases and LPG,
More informationPneumatic Gripping Modules. Pneumatic 2-Finger Radial Grippers
Pneumatic Gripping Modules Pneumatic 2-Finger Radial Grippers Pneumatic Gripping Modules Pneumatic 2-Finger Radial Grippers 2-FINGER RADIAL GRIPPERS Series Size Page Universal Grippers GWB 676 GWB 34 680
More informationModel MTB-ASME Horizontal Bladder Tanks
DATA SHEET Model MTB-ASME Horizontal Bladder Tanks Features n UL Listed and FM Approved for use with various proportioners and foam concentrates n 175 psi (12.1 bar) maximum allowable working pressure
More informationSeries P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)
Series P48 Pressure Controls for Steam, Air or (hot) Water Product Bulletin The series P48 pressure controls are designed as operating or high/low cut-out control on steam, air or (hot) water applications.
More informationC437D,E,F,G,H,J,K and C637B Gas Pressure Switches
C437D,E,F,G,H,J,K and C637B Gas Pressure Switches FEATURES PRODUCT DATA GENERAL The C437 and C637 Gas Pressure Switches are pressureactuated switching devices used in industrial gas system applications
More informationSTEEL TRENCH SHIELDS DW MODELS
STEEL TRENCH SHIELDS DW MODELS 3330 S. SAM HOUSTON PKWY E. HOUSTON, TEXAS 77047 Phone: 713.943.0750 Toll Free: 800.231.6662 Fax: 713. 943.8483 COPYRIGHT, U.S.A., SPEED SHORE CORPORATION, 2009 April 16,
More informationFlexfence Swaging Unit. Product Manual. Release 02/16.
Product Manual www.ingalcivil.com.au 1.0 Safety Precautions 1.1 Personal Protection While operating this equipment it is recommended that the following personal protective equipment be worn; Long sleeve
More informationTechnical Data. General specifications Switching element function Rated operating distance s n 5 mm
00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,
More information