References, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)

Size: px
Start display at page:

Download "References, characteristics. References (1) Complementary characteristics not shown under general characteristics (page 30395/3)"

Transcription

1 References, characteristics Electromechanical pressure switches For power circuits, type XMP. IP degree of protection Size (87 psi). Adjustable differential, for regulation between thresholds Switches with -pole N/C or -pole N/C contact Fluid connection G / (BSP female) Adjustable range of switching point (PH) () (. 87 psi) Type of contact -pole N/C -pole N/C References () Bare case XMP-AB XMP-AC Case with reset knob XMP-BB Case with On/Off knob XMP-CB XMP-CC Weight (kg).. Switches with straight decompression valve, instant connection Bare case XMP-DB XMP-DC Case with On/Off knob XMP-EB XMP-EC Weight (kg).. Complementary characteristics not shown under general characteristics (page 9/) Possible Min. at low setting.8 (. psi) differential (subtract from Min. at high setting. (7. psi) PH to give PB) Max. at high setting. (.9 psi) Destruction pressure Mechanical durability ( psi) million operating cycles Cable entry entries tapped for n cable gland, conforming to NF C 8- (DIN Pg.) Pressure switch type Operating curves Pressure PH PB,,8,8 Maximum differential Minimum differential Time Adjustable value Accessories : page 99/ Dimensions : page 99/ 9_Ver.-EN.fm/

2 x G / (BSP female) G /8 (BSP female) (. 87 psi) -pole N/C -pole N/C -pole N/C -pole N/C XMP-AB XMP-AC XMP-BB XMP-CB XMP-CC.. Switches with straight decompression valve, instant connection XMP-DB XMP-DC XMP-EB XMP-EC XMP-EB XMP-EC (. psi). (7. psi). (.9 psi) ( psi) million operating cycles entries incorporating n plastic cable gland (DIN Pg.) entries tapped for n cable gland, conforming to NF C 8- (DIN Pg.) Clamping capacity : Ø 9 to mm Terminal connections XMP-///B//// XMP-///C//// () References for individually packaged switches. Also available packaged in lots of, to order : add the suffix C to the reference selected from above. Example : reference for lot of XMP-AB pressure switches in one package becomes XMP-ABC. Other versions Pressure switches not listed above, comprising the equipment proposed for the choice of reference. Please consult your Regional Sales Office. 9_Ver.-EN.fm/

3 References, characteristics Electromechanical pressure switches For power circuits, type XMP. IP degree of protection Size (7 psi). Adjustable differential, for regulation between thresholds Switches with -pole N/C or -pole N/C contact Fluid connection G / (BSP female) Adjustable range of switching point (PH) (). (8.8 7 psi) Type of contact -pole N/C -pole N/C References () Bare case XMP-AB XMP-AC Case with reset knob XMP-BB Case with On/Off knob XMP-CB XMP-CC Weight (kg).. Switches with straight decompression valve, instant connection Bare case XMP-DB XMP-DC Case with On/Off knob XMP-EB XMP-EC Weight (kg).. Case with On/Off knob XMP-RB XMP-RC Weight (kg).. Complementary characteristics not shown under general characteristics (page 9/) Possible Min. at low setting (. psi) differential (subtract from Min. at high setting.7 (. psi) PH to give PB) Max. at high setting 8. (.8 psi) Destruction pressure Mechanical durability ( psi) million operating cycles Cable entry entries tapped for n cable gland, conforming to NF C 8- (DIN Pg.) Pressure switch type Operating curves 8 Pressure PH PB, Maximum differential Minimum differential,, 8, Time Adjustable value Accessories : page 99/ Dimensions : page 99/ 9_Ver.-EN.fm/

4 x G / (BSP female) G /8 (BSP female). (8.8 7 psi) -pole N/C -pole N/C -pole N/C -pole N/C XMP-AB XMP-AC XMP-BB XMP-CB XMP-CC.. Switches with straight decompression valve, instant connection XMP-DB XMP-DC XMP-EB XMP-EC XMP-CB XMP-CC.... (. psi).7 (. psi) 8. (.8 psi) ( psi) million operating cycles entries incorporating n plastic cable gland (DIN Pg.) entries tapped for n cable gland, conforming to NF C 8- (DIN Pg.) Clamping capacity : Ø 9 to mm Terminal connections XMP-///B//// XMP-///C//// () References for individually packaged switches. Also available packaged in lots of, to order : add the suffix C to the reference selected from above. Example : reference for lot of XMP-AB pressure switches in one package becomes XMP-ABC. Other versions Pressure switches not listed above, comprising the equipment proposed for the choice of reference. Please consult your Regional Sales Office. 9_Ver.-EN.fm/

5 References, characteristics Electromechanical pressure switches For power circuits, type XMP. IP degree of protection Size (. psi). Adjustable differential, for regulation between thresholds Switches with -pole N/C or -pole N/C contact Fluid connection G / (BSP female) Adjustable range of switching point (PH) () Type of contact. (.7. psi) -pole N/C References () Bare case Case with reset knob Case with On/Off knob XMP-AB XMP-BB XMP-CB Weight (kg). Case with On/Off knob XMP-RB Weight (kg).7 Complementary characteristics not shown under general characteristics (page 9/) Possible Min. at low setting. (9. psi) differential (subtract from Min. at high setting. (. psi) PH to give PB) Max. at high setting (9 psi) Destruction pressure Mechanical durability ( psi) million operating cycles Cable entry entries tapped for n cable gland, conforming to NF C 8- (DIN Pg.) Pressure switch type Operating curves Pressure PH PB, Maximum differential Minimum differential,, Time Adjustable value Accessories : page 99/ Dimensions : page 99/ 9_Ver.-EN.fm/

6 G / (BSP female). (.7. psi) -pole N/C XMP-AC XMP-CC. XMP-RC.7. (9. psi). (. psi) (9 psi) ( psi) million operating cycles entries tapped for n cable gland, conforming to NF C 8- (DIN Pg.) Terminal connections XMP-///B//// XMP-///C//// () References for individually packaged switches. Also available packaged in lots of, to order : add the suffix C to the reference selected from above. Example : reference for lot of XMP-AB pressure switches in one package becomes XMP-ABC. Other versions Pressure switches not listed above, comprising the equipment proposed for the choice of reference. Please consult your Regional Sales Office. 9_Ver.-EN.fm/7

7 References, characteristics Electromechanical pressure switches For power circuits, type XMP. IP degree of protection Sizes to (87 to. psi). Adjustable differential, for regulation between thresholds. Switches with -pole N/C or -pole N/C contact Fluid connection G / (BSP female) Adjustable range of switching point (PH) () (. 87 psi). (8.8 7 psi). (.7. psi) Type of contact -pole N/C -pole N/C -pole N/C -pole N/C -pole N/C -pole N/C References () Case with On/Off knob XMP-RB XMP-RC XMP-RB XMP-RC XMP-RB XMP-RC Weight (kg) Complementary characteristics not shown under general characteristics (page 9/) Possible Min. at low setting.8 (. psi) (. psi). (9. psi) differential (subtract from Min. at high setting. (7. psi).7 (. psi). (. psi) PH to give PB) Max. at high setting. (.9 psi) 8. (.8 psi) (9 psi) Destruction pressure ( psi) ( psi) ( psi) Mechanical durability million operating cycles Cable entry entries tapped for n cable gland, conforming to NF C 8- (DIN Pg.) Adjustment of high setting point (PH) By screw-nut Pressure switch type Operating curves XMP-R///// XMP-R///// XMP-R///// 8 Pressure PH PB,,8,8,,, 8,,,, Time Adjustable value Maximum differential Minimum differential Maximum differential Minimum differential Maximum differential Minimum differential Accessories : page 99/ Dimensions : page 99/ 9_Ver.-EN.fm/8

8 x G / (BSP female) (. 87 psi). (8.8 7 psi). (.7. psi) -pole N/C -pole N/C -pole N/C -pole N/C -pole N/C -pole N/C XMP-RB XMP-RC XMP-RB XMP-RC XMP-RB XMP-RC (. psi) (. psi). (9. psi). (7. psi).7 (. psi). (. psi). (.9 psi) 8. (.8 psi) (9 psi) ( psi) ( psi) ( psi) million operating cycles entries tapped for n cable gland, conforming to NF C 8- (DIN Pg.) By screw-nut Terminal connections XMP-///B//// XMP-///C//// () References for individually packaged switches. Also available packaged in lots of, to order : add the suffix C to the reference selected from above. Example : reference for lot of XMP-RB pressure switches in one package becomes XMP-RBC. Other versions Pressure switches not listed above, comprising the equipment proposed for the choice of reference. Please consult your Regional Sales Office. 9_Ver.-EN.fm/9

Electromechanical pressure switches

Electromechanical pressure switches Presentation Electromechanical pressure switches OsiSense XM For power circuits, type XMP Presentation Pressure switches type XMP are switches for power circuits (direct switching), with an adjustable

More information

Electromechanical pressure switches

Electromechanical pressure switches References : pages / and / page /5 Presentation Functions Pressure switches type XMX and XMA are switches for control circuits, with an adjustable differential. They are used to control the pressure of

More information

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type

XMPA12B2142 pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Characteristics pressure sensor XMP - 12 bar - G 1/4 female - 2 NC - without control type Main Range of product Pressure sensor type Pressure sensor name Pressure sensor size OsiSense XM Electromechanical

More information

Limit switches OsiSense XC Special For material handling applications, type XC1 AC

Limit switches OsiSense XC Special For material handling applications, type XC1 AC Presentation For material handling applications, type XC C b XC C with slow break contacts v With head for linear movement () 00_ 00_ 000_ Page / 00_ 00_ XCC XCC Page / XCC XCC / General characteristics

More information

XML Electromechanical Pressure Switches

XML Electromechanical Pressure Switches Selection Guide Industrial Switches Type of installation ontrol circuits Applications Media controlled Type of operation Air, water, hydraulic oils, corrosive fluids, viscous products Fixed differential:

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure SITRANS P measuring instruments for pressure Z series for gage pressure Siemens AG 008 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and

More information

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure

2 Overview. SITRANS P measuring instruments for pressure. Transmitters for gage and absolute pressure. Z series for gage pressure Z series for gage pressure Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Pressure Switch for gas and air GGAO-A4

Pressure Switch for gas and air GGAO-A4 Pressure Switch for gas and air GGAO-A4 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 Commonwealth of Massachusetts Approved Product Approval code G3-0106-191 Gas pressure switch Codes

More information

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure

1 Overview. Pressure Measurement Transmitters for basic requirements. 1/16 Siemens FI SITRANS P220 for gauge pressure Siemens AG 204 Overview The pressure transmitter SITRANS P220 measures the gauge pressure of liquids, gases and vapors. Stainless steel measuring cell, fully welded Measuring ranges 2.5 to 600 bar (36.3

More information

Pressure Measurement Single-range transmitters for general applications

Pressure Measurement Single-range transmitters for general applications Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/16 Siemens FI US Edition Siemens AG 206 Overview Design Device structure without explosion protection The pressure transmitter consists of a piezoresistive measuring cell with a diaphragm installed in a stainless steel enclosure.

More information

Pressure switch and Thermostat CAS

Pressure switch and Thermostat CAS Data sheet Pressure switch and Thermostat CAS The CAS Series consists of a series of pressure controlled switches and temperature controlled switches. In this series, special attention has been given to

More information

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview

Pressure Measurement. Transmitters for basic requirements SITRANS P Z for gauge pressure. 2/4 Siemens FI Overview f gauge pressure Siemens AG 010 Overview Design The main components of the pressure transmitter are: Brass housing with silicon measuring cell and electronics plate Process connection Electrical connection

More information

Pressure controls, differential pressure controls type RT

Pressure controls, differential pressure controls type RT Data sheet Pressure controls, differential pressure controls type RT Introduction Features An RT pressure control contains a pressure operated single-pole changeover contact, the position of which depends

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. Supplied with an electric input signal of 4 to 20

More information

Prewired position switches FA series

Prewired position switches FA series 2 Prewired position switches FA series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 51 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. 13 and No. 0 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR

TANDEM MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR SIT Group 836-837 TANDEM MULTIFUNCTIONAL GAS CONTROL MODULATOR FOR OUTLET GAS FLOW: STEPPED (836 TANDEM) - CONTINUOUS (837 TANDEM) SERVO-CONTROLLED PRESSURE REGULATOR ALL ADJUSTMENTS ACCESSIBLE FROM ABOVE

More information

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119

Data sheet Pressure switch type CS December 2001 DKACT.PD.P10.A B1119 Pressure switch type CS December 2001 DKACT.PD.P10.A2.02 520B1119 Introduction Pressure switch type CS is part of the Danfoss pressure control range. All CS pressure switches have a built-in pressure-operated,

More information

Differential pressure switch MP 54, MP 55 and MP 55A

Differential pressure switch MP 54, MP 55 and MP 55A Data sheet Differential pressure switch MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors against low lubricating

More information

IP65 Air Differential Pressure Switch

IP65 Air Differential Pressure Switch Page 1 of 5 PA-DPS-9x IP65 Air Differential Pressure Switch Features: Benefits: Close switching differential IP65 Housing Duct fixing kit included Switching point easily adjusted with scale in One screw

More information

Pressure switch for gas and air

Pressure switch for gas and air Pressure switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF GXX_A4

More information

Types and approvals. Page 1/6. Data Sheet

Types and approvals. Page 1/6. Data Sheet Page 1/6 Panel-mounting Thermostats EM Series as: Protection temperature monitor STW (STB) Protection temperature limiter STB tested to DIN 3440 and Pressure Equipment Directive 97/23/EC Brief description

More information

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS

Electropneumatic Positioner and Pneumatic Positioner Type 3760 JIS Electropneumatic Positioner and Pneumatic Positioner Type 3760 Application Single-acting positioners for direct attachment to pneumatic control valves. An electric standardized signal of 4 to 20 ma or

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Pressure Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL File # MH 668 CSA Certified CSA C. No. LR File # 07 FM Approved Class 0, 0 File # J.I. Y9A9.AF Commonwealth of Massachusetts

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

Measurement of Low GAS & Liquid Flows

Measurement of Low GAS & Liquid Flows Measurement of Low GAS & Liquid Flows The Measurement Measurement with a float in a tapered borosilicate glass tube. Series 2100 with a 100 mm flow tube Series 2150 with a 150 mm flow tube Series 2300

More information

Pneumatic spool valve islands

Pneumatic spool valve islands Pneumatic spool valve islands P7.GB.R MEGA SPOOL VALVE ISLANDS MEGA pneumatic spool valve islands offer maximum performance along with flexibility, easy installation and simple operation. Due to their

More information

Differential pressure controls, Type MP 54, 55 and 55A

Differential pressure controls, Type MP 54, 55 and 55A MAKING MODERN LIVING POSSIBLE Technical brochure Differential pressure controls, Type MP 54, 55 and 55A MP 54 and oil pressure controls are used as safety switches to protect refrigeration compressors

More information

Pressure Switch for gas and air

Pressure Switch for gas and air Switch for gas and air GAO-A4 GMH-A4 GML-A4 UL Listed UL 353 File # MH 16628 CSA Certified CSA C22.2 No. LR 53222 Certification file # 201527 FM Approved Class 3510, 3530 File # J.I. 1Y919.AF Commonwealth

More information

Emergency Stop Devices/Rope Pull Switches

Emergency Stop Devices/Rope Pull Switches Rope pull switch with pulltoreset button for emergency stop device Metal housing Emergency stop device with detent mechanism according to EN ISO 13850 and EN 602041 Clamping head for pull rope Indication

More information

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C

Pressure decay sensor Pressure decay sensor Flow at 90 psi (6 bars) Tripping point at 90 psi (6 bar) supply Connection Mechanical life Relay C Position Detectors Order/Technical Support Tel: (800) 6773 / FAX: (800) 677386 / www.crouzetusa.com / Pressure decay sensor Pressure decay sensor 8 04 02 Flow at 90 psi (6 bars) Tripping point at 90 psi

More information

Two-port valves, male threaded, PN25

Two-port valves, male threaded, PN25 4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

Pneumatic pressure switch 20DD

Pneumatic pressure switch 20DD Sensor system: stainless steel 0,2 to 6 bar Microswitch with gold plated contacts (suitable for intrinsically safe operation) High accuracy (max. scattering < 1,5%) Excellent sealing properties (better

More information

Pressure controls for hydro carbons, zone II applications, Type KPE

Pressure controls for hydro carbons, zone II applications, Type KPE MAKING MODERN LIVING POSSIBLE Technical brochure Pressure controls for hydro carbons, zone II applications, Type KPE KPE pressure controls for use in refrigeration and air conditioning systems with hydrocarbons

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic

More information

Differential Pressure Control Types MP 54, MP 55 and MP 55A

Differential Pressure Control Types MP 54, MP 55 and MP 55A MAKING MODERN LIVING POSSIBLE Data sheet Differential Pressure Control Types MP 54, MP 55 and MP 55A MP 54 and MP 55 oil differential pressure controls are used as safety switches to protect refrigeration

More information

Level switches Series LD Vibrating fork level switch for liquids and solids

Level switches Series LD Vibrating fork level switch for liquids and solids Level switches Series LD Vibrating fork level switch for liquids and solids Robust and compact Suitable for liquids (model LD61) and solids (model LD60) No moving parts, low maintenance Corrosion resistant

More information

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

QPL... Pressure Switches. Siemens Building Technologies HVAC Products 7 221 Pressure Switches QPL... The pressure switches are used for monitoring gas or air pressures. When the pressure falls below the switching point, the associated electrical circuit will open or switch

More information

Compact pressure switches for gas and air

Compact pressure switches for gas and air Compact pressure es for gas and air / 5.0 Printed in Germany Edition 0.8 Nr. 9 544 6 Technical description The pressure is an adjustable compact pressure according to EN 854 for combustion plants. The

More information

Compact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min

Compact Ejectors. Compact Ejectors SCPi / SMPi Suction rate from 75 l/min to 185 l/min Compact Ejectors Suitability for Industry-Specific Applications Applications Handling of air-tight as well as porous workpieces supply and vacuum monitoring in automated systems For use in sheet metal

More information

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP

compact ejector, Series ECM with Adjustable release pulse with silencer With filter vacuum switch: electronic 2 x PNP 00134428 Type Miniature compact injector Ambient temperature min./max. +0 C / +0 C Medium temperature min./max. +0 C / +0 C Working pressure min./max. 2. bar / 6 bar Medium Compressed air Max. particle

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800

Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 800 KROHNE 1/22 7.236.22. GR Miniature flowmeters DK 46, DKR 46 DK 47, DK 48, DK 8 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters

More information

Gas Pressure Switch for DMV safety shutoff valves

Gas Pressure Switch for DMV safety shutoff valves Gas Switch for DMV safety shutoff valves GAO-A GMH-A GML-A UL Listed UL 353 File # MH 1668 CSA Certified CSA C. No. LR 53 File # 0157 FM Approved Class 3510, 3530 File # J.I. 1Y9A9.AF Commonwealth of Massachusetts

More information

SOLENOID VALVES AND PNEUMATIC VALVES

SOLENOID VALVES AND PNEUMATIC VALVES 9 S E R I E S Electropneumatically and pneumatically operated valves Series 9 Assembly with sub-base (ISO 5599/1 Standards) Sizes 1, 2 and 3 The Series 9 electropneumatically or pneumatically operated

More information

2-port seat valves PN25 with externally threaded connections

2-port seat valves PN25 with externally threaded connections 4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with

More information

Flamco Flamco-Fill STA Flamco-Fill STM

Flamco Flamco-Fill STA Flamco-Fill STM STA STM Typ STA 5936 Typ STM 5937 GB Installation and operating instructions 1999, 2 Contents GB UK Limited P.O. Box 9, Washway Lane, St. Helens, Merseyside WA10 6FE United Kingdom Telephone: 01744 744744

More information

Pressure switches for air and water CS

Pressure switches for air and water CS Data sheet Pressure switches for air and water CS CS pressure switches have a built-in pressure operated, three-pole switch. The contact position of which depends on the pressure in the connector and the

More information

Proportional pressure regulators VPPE

Proportional pressure regulators VPPE Proportional pressure regulators VPPE Proportional pressure regulators VPPE Product range overview Function Version Pneumatic connection Proportional pressure regulator Nominal size for pressurisation/

More information

Differential pressure switch / Lube oil protection control MP 54 and MP 55

Differential pressure switch / Lube oil protection control MP 54 and MP 55 Data sheet Differential pressure switch / Lube oil protection control MP 54 and MP 55 MP 54 and MP 55 oil differential pressure switches are used as safety switches to protect refrigeration compressors

More information

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH.

Note: the lock-out circuit must be in accordance with Section 8.7 of DIN/VDE Twin thermostats ATH.-SW-2020 ATH.-SW-2070 ATH. M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 3603 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-60 E-mail: mail@jumo.net Internet: www.jumo.net

More information

TECHNICAL CHARACTERSTICS

TECHNICAL CHARACTERSTICS and solenoid valves spool version GM - GL series Type of valves with dorsal consumption: GM-...series with integrated connections GL-...series without connections TECHNICAL CHARACTERSTICS Ambient temperature:

More information

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998

Auxiliary valve QDS6 Sequence valve, 3-way. Catalogue (GB) (US) October 1998 Auxiliary valve Sequence valve, 3-way Catalogue 9129 8542-02 (GB) 9129 8542-06 (US) October 1998 Sequence valve, 3-way Applications The sequence valve is designed to open or close a hydraulic pilot signal

More information

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in

More information

Pressure switch Type BCP

Pressure switch Type BCP Data sheet Pressure switch Type BCP The BCP type is a series of dedicated switches for safety and monitoring of steam and hot water boilers. The BCP incorporates a single-pole changeover microswitch where

More information

Pressure switches and thermostats, type KPS

Pressure switches and thermostats, type KPS Description KPS units are pressure-controlled switches. The position of the contacts depends on the pressure in the inlet connection and the set scale value. In this series, special attention has been

More information

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1

ATH 500 M. Pumping speed ATH 500 M. 3.1 Vacuum generation / Turbopumps / Magnetically levitated / ATH 500 M. Page 398 / Part 3.1 ATH 500 M Compact integrated drive Installation in any orientation Water or air cooled CE marked and ROHS compliant Heated version (MT) available for corrosive applicaitons. Pumping speed N 2 He H 2 Ar

More information

Air Differentail Pressure Switch

Air Differentail Pressure Switch Page 1 of 5 PA-DPS-8x Air Differentail Pressure Switch Features: Benefits: Close switching differential Duct fixing kit included Switching point easily adjusted with scale in Pascals Conduit entry can

More information

Infrared Linescanners

Infrared Linescanners Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Pneumatic valve islands

Pneumatic valve islands Pneumatic valve islands The MEGA solenoid air operated spool valve JOUCOMATIC offers a concept of solenoid air operated spool valves which can be fitted together to form islands. Due to its new patented

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

Tightness controls TC 1 3 and TC 4

Tightness controls TC 1 3 and TC 4 Tightness controls TC 1 3 and TC 4 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted to different systems

More information

Pressure switch KP-E. Data sheet

Pressure switch KP-E. Data sheet Data sheet Pressure switch KP-E KP-E pressure switches for use in refrigeration and air conditioning systems are equipped with SPDT gold plated contacts and stainless steel bellows. The high pressure switches

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

Pressure switch, Differential pressure switch and Thermostat RT-E

Pressure switch, Differential pressure switch and Thermostat RT-E Data sheet Pressure switch, Differential pressure switch and Thermostat RT-E The RT-E series consist of pressure and differential pressure switches as well as thermostats. The units are designed for industrial

More information

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.

DMK 458. Pressure Transmitter for Marine and Offshore. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.25 % FSO option: 0. Pressure Transmitter for Marine and Offshore Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0. % FSO Nominal pressure from 0... 40 mbar up to 0... 0 bar Output signals -wire:

More information

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES

PRESSURE REGULATORS AND FLOWMETERS, ALL MEDICAL GASES PRESSURE REGULATORS ALL MEDICAL GASES In this section we propose our pressure regulators (FM series, MU and MERCURY ) and our Rs flowmeters for applications other than oxygen therapy (presented in the

More information

Pressure independent control valve (PICV) FLOWMATIC

Pressure independent control valve (PICV) FLOWMATIC Pressure independent control valve (PICV) FLOWMATIC 145 series FM 21654 003 01262/19 GB replaces dp 01262/17 GB Function The pressure independent control valve is a device composed of an automatic flow

More information

Pilot valves for pilot operated servo valves

Pilot valves for pilot operated servo valves Data sheet Pilot valves for pilot operated servo valves The range of pilot valves consists of: Constant-pressure pilot valve, type CVP (LP) and CVP (HP) Differential-pressure pilot valve, type CVPP (LP)

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

R84G - Excelon Plus Modular System Pressure regulators

R84G - Excelon Plus Modular System Pressure regulators > Port size: 3/8... 3/4 (ISO G/PTF) > Excelon Plus design allows in-line installation or modular installation with other Excelon Plus products > Easy to read flush mounted integrated pressure gauge as

More information

TeSys protection components

TeSys protection components Presentation, description -pole thermal overload relays TeSys D Presentation TeSys D thermal overload relays are designed to protect a.c. circuits and motors against: b overloads, b phase failure, b excessively

More information

Prewired position switches FA series

Prewired position switches FA series Prewired position switches Technical data Housing Made of metal, coated with baked epoxy powder 2 m wired cable with 5x0,5 mm 2 wires marked SEV and IMQ Protection degree: IP6 General data Ambient temperature:

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI US Edition Siemens AG 07 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

Pressure switch and Thermostat Type KPS

Pressure switch and Thermostat Type KPS MAKING MODERN LIVING POSSIBLE Data sheet Pressure switch and Thermostat Type KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has

More information

Climatic Independent Level Sensor LAR

Climatic Independent Level Sensor LAR 1 Product Information LAR-361 LAR-761 Climatic Independent Level Sensor LAR Application / Specified usage Authorizations Hydrostatic level measurement in humid ambiance Special applicable for exterior

More information

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type

1 LS unloading (control valve, orifice, none) 2 LS max pressure relief. 3 Spool type Flow Control Valve Series LVM.. high flow rates (8 l/min) flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports proportional flow-sharing

More information

Solenoid valve type EVR for Hydrocarbons

Solenoid valve type EVR for Hydrocarbons MAKING MODERN LIVING POSSIBLE Technical brochure Solenoid valve type EVR for Hydrocarbons EVR for Hydrocarbons is a direct or servo operated solenoid valve especially designed for liquid, suction, and

More information

Residential Pressure Booster Systems

Residential Pressure Booster Systems Residential Pressure Booster Systems HOW IT WORKS When the pressure available is insuffi cient it is necessary to install a boosting system. FLUX BOOSTING SYSTEM starts and stops according to the user

More information

Pressure switch and Thermostat KPS

Pressure switch and Thermostat KPS Data sheet Pressure switch and Thermostat KPS The KPS Series consists of a series of pressure and temperature controlled switches. In this series, special attention has been given to meeting demands for

More information

Data sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782

Data sheet. Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E B0782 Data sheet Pressure switches and thermostats Type KPS 10/2003 DKACT.PD.P10.E2.02 520B0782 Survey Type KPS pressure switches 1. Standard pressure switches Range Further -1 0 10 20 30 40 50 60 bar P e Type

More information

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54)

Series P48. Pressure Controls for Steam, Air or (hot) Water. Product Bulletin. Generous wiring space provided. Splash-proof enclosure (IP54) Series P48 Pressure Controls for Steam, Air or (hot) Water Product Bulletin The series P48 pressure controls are designed as operating or high/low cut-out control on steam, air or (hot) water applications.

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads

TBV-CM. Combined control & balancing valves for small terminal units For modulating control NPT threads TBV-CM Combined control & balancing valves for small terminal units For modulating control NPT threads IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling

More information

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3

More information

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

F05MSV-N* CONTINENTAL HYDRAULICS FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK CONTINENTAL HYDRAULICS F05MSV-N* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F05MSV-N* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400

More information

F series Foot Switches

F series Foot Switches F series Foot Switches ITC presents a complete line of foot switches from Bernstein, designed to respond to the most stringent requirements for machine control and safety applications. The F series includes

More information

PROVENGAS AUTOMATIC PROVING SYSTEMS FOR GAS INSTALLATION

PROVENGAS AUTOMATIC PROVING SYSTEMS FOR GAS INSTALLATION PROVENGAS AUTOMATIC PROVING SYSTEMS FOR GAS INSTALLATION Provengas Labsafe PGLS001 Provengas Cooksafe PGCS003 2 Provengas Labsafe has been designed as a gas pressure proving system for use in schools and

More information

OPTIBAR P 1010 C Technical Datasheet

OPTIBAR P 1010 C Technical Datasheet Technical Datasheet Pressure transmitter with recessed diaphragm for general applications Wide variety thanks to modular design Measuring ranges up to 250 bar / 3750 psi High overload and temperature stability

More information

Mechanical pressure switches Liquids and gases. Negative pressure switches (vacuum switches)

Mechanical pressure switches Liquids and gases. Negative pressure switches (vacuum switches) 44 Liquids and gases VCM/VNM Negative pressure switches (vacuum switches) FEMA negative pressure switches detect the pressure difference relative to atmospheric pressure. All data relating to the switching

More information

3.1. Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and according to EN : 2012

3.1. Ex-e/i Cable Glands Plastic version for Zone 1, 2, 21 and according to EN : 2012 .1 x-e/i Cable Glands Plastic version for Zone 1, 2, 21 and 22 1 - according to N 60079-0: 2012 Conform with latest standards Cable glands with metric screwin threads are now standard and had replace the

More information