IECEx Certificate of Conformity Annexe

Size: px
Start display at page:

Download "IECEx Certificate of Conformity Annexe"

Transcription

1 for Certificate No.: IECEx TSA X Issue No.: 1 Equipment description pertaining to Issue 0 of this Certificate: A range of electrical power distribution, control, protection and monitoring equipment that is intended for application to underground coal mining operations and is designated as the AFE00 Series. Detail of the enclosure constructions and the enclosed equipment is described by the manufacturer s design documents. The rating of the enclosed electrical equipment is up to 000 V and up to 150 A. The equipment consists of up to ten types of welded steel plate flameproof enclosures designated as the types AFE01, AFE0, AFE03, AFE04, AFE05, AFE06, AFE07, AFE30, AF E40, AFE90 and AFE47. These types of enclosures differ in their overall dimensions (hence volume) and may be fabricated as separate standalone enclosures or an assembly of enclosures in series sharing internal walls with common top, bottom and rear plates. The enclosure AFE47 is provided for cable protection and situated behind the enclosure. The enclosure AFE47 does not have any terminals and it may produce negligible heat, hence that enclosure is not considered as ex protected enclosure. AFE47 may vary in length depending upon site requirement and numbers of enclosures fed through cables. The enclosures may be fabricated from mild steel (minimum of 50 grade) or stainless steel or a combination of both. Assembly of an enclosure may be mirror imaged to the certification drawings. Access to the interior of an enclosure, or compartment within an enclosure, is via a bolted hinged door or panel. Position of hinges and door openings may vary to suit site requirements. The following are options for the assembly of the equipment: The enclosures, or parts thereof, may be manufactured from mild steel grade 50 or stainless steel of superior grade to mild steel grade 50. Inclusion of any of the certified components to the enclosure as listed in Schedule 1. Inclusion of any of the components that are assessed together with the equipment as listed in Schedule. Addition of a rectangular trunking piece to an end wall of an enclosure may be fitted as per detail in Schedule Provision of electrical and/or mechanical interlocks to doors. Use of nonmetallic components as detailed in Schedule 3. Arrangement of entries to the enclosures in accordance with Schedule 4. Equipment construction and use restrictions in accordance with Schedule 5. Design criteria for enclosure series, and options therein, as detailed in drawings AFE001. Typical electrical circuit diagram is detailed in drawing AFE100, and may vary to suit site/client requirements. Fitting of an Oring gasket on each door, attachment or cover of an enclosure for ingress protection IP66. Provision of vertical panels or horizontal trays for the mounting of internal components, or in the case of large components fitted directly to bottom plate. Provision of threaded blind holes for the attachment of auxiliary items, as shown in drawing AFE 003. Provision of plain blind holes on the outside surfaces for fitment of drive screws, as shown in drawing AFE003. Page 1 of 1

2 for Certificate No.: IECEx TSA X Issue No.: 1 Schedule 1. Types of separately IECEx certified components (certified components) that may be incorporated into the AFE00 Series enclosures. Component type Certificate number or certification Push / rotary / switchgear operator AFC001 Receptacle / adaptor blanking plate AFC060 Conversion assemblies AFC070. See Note 1. Plugs and reducers AFC040 Compression type cable glands Multi conductor socket / bushing for IS circuits. Typically fitted to an exterior wall of an enclosure. Cable coupling devices such as receptacles and coupler adaptors. See Note. IECEx TSA U Interface as included in this report Plain cylindrical or threaded aperture in enclosure IECEx TSA U Bolted flange joint with optional threaded aperture IECEx TSA U IECEx TSA or other equipment certified component having identical threaded joint to AFC040 IECEx equipment certified to IEC / IECEx PTB U or other equipment certified component having identical threaded joint to AFC040 IECEx TSA U or other equipment certified component having identical flanged joint to AFC040 Bolted flange joint Threaded joint Threaded joint A type of bushing. Compound filled body with threaded joint attachment identical to AFC040 Bolted flange joint to blanking plate AFC060 dimensions Note 1. Conversion assemblies refers to a component that adapts varying sizes of flange mountings and essentially consists of two flange plates joined by a short tube section that may be filled with sealing compound. Conversion assemblies are used for mounting configurations. Note. The cable coupling device, typically a receptacle or adaptor, must have a flange interface (mounting pad detail) that provides the same attachment and flamepath provision as the range of blanking plates AFC060. The bushing of any such receptacle or adaptor that completes the enclosure must comply with the requirements of IEC and IEC for nonmetallic materials. Items used for test and assessment were coupler devices covered by TestSafe report 8684 applied here according to Ex TAG DS 004/006. National differences for Australia would include the use of receptacles and adaptors complying with the Australian Standards 199 and 1300, but only where these are also IECEx certified as complying with IEC and IEC Schedule. Assessment of components, not separately certified, is based on review of test results and assessments contained in TestSafe report Page of 1

3 for Certificate No.: IECEx TSA X Issue No.: 1 Component type Drawing reference Interface Polycarbonate window(s) AFC050 Cemented to machined area around opening and clamped by bolted frame. Trunking plate. Plain (blanking) or machined for up to 4 power bushings or receptacle / adaptor mountings and up to 6 (M3 max) threaded entries) AFC090 (Bushing) AFE005 (Trunking flange) AFE004 (cable Coupling devices) Bolted flange joint. See Note 1. Trunking, various sizes AFE005 Welded or bolted flanged joint. See Note. Power / insulator terminal bushing(s). See Note 3. AFC090 Cemented flange joint. Note 1. When used to mount high power bushings this plate would be welded or bolted to a transformer enclosure having a type of protection Ex p. The component is included in this report to assess the effectiveness of the flamepath on the Ex d enclosure side of the plate and the cemented joint of the bushing attachment. Note. This trunking has a machined flange which is for a bolted connection to a flange plate of a separate enclosure or for attachment of a plate that has provision for restrained receptacles, adaptors, high current bushings or threaded entries. Note 3. Power (terminal) bushings are high current bulkhead electrical feed through devices with solid epoxy, glass or ceramic insulation and with stud or bolted conductor connection. The generic type for this application has a 4fastener flange forming a cemented joint with a plate or enclosure wall. This test report relates only to the enclosure interface joint of the bushing and not to a specific type of bushing, which is outside the scope of this report. Schedule 3. Nonmetallic parts (introduced by use of components, etc). Component Drawing reference Nonmetallic part Polycarbonate window(s) AFC050 Lexan MR10 polycarbonate material and Silastic RTV 1080 cement Cable terminating device; Receptacle or coupler adaptor Multi contact socket with threaded attachment Power terminal bushing (Solid epoxy, glass or ceramic bushing with stud or bolted conductor) Conductor bushing with threaded attachment AFE001 Phase and pilot conductor pin bushing / insulation AFE001 A3 T9 N/A (IECEx equipment certified to IEC / ) Insulation (bushing) compound of sockets Solid epoxy, glass or ceramic insulator Solid epoxy bushing with through conductors (typical) Page 3 of 1

4 for Certificate No.: IECEx TSA X Issue No.: 1 Schedule 4. Type and number of apertures for components walls / door panel. (Refer to next page) Note 1. Note. Note 3. Note 4. Note 5. Note 6. Note 7. A greater number of windows may be provided if the total area of metal removed is the same or less than the area shown in parentheses. Maximum number of entries (without windows) of M5 or M3 (threaded joint) or 17 mm or 0 mm nominal (plain joint), for attachment of operators. When windows are fitted, the number of entries is reduced by the number of entries as per Table of drawing AFE00_1 for the specific window type. For threaded entries, the total permitted is based on them all being M63. A greater number of entries may be provided if the total area of all threaded entries in a wall or panel is equal to or less than the area of the maximum permitted M63 threaded entries. For plain entries, the total is based on them all being 90 mm diameter. A greater number of entries may be provided if the total area of all plain entries in a wall or panel is equal to or less than the area of the maximum permitted 90 mm plain entries. Where there are mixed types of entries in a particular panel, the total area of metal removed from that panel must not exceed the limit shown (mm ) in parentheses for that fitment. Provision of a welded or bolted trunking to a flange plate of a separate enclosure or for attachment of a plate that has provision for restrained receptacles, adaptors, high current bushings or threaded entries (refer drawings AFE005 and AFC090). Two threaded entries as per Note 3 may be provided with a trunking facility on the same wall. Refer to note 7 of drawing AFE00_1 Page 4 of 1

5 for Certificate No.: IECEx TSA X Issue No.: 1 Enclosure AFE00 Series Type and Number of Aperture for components Fitment Windows in front Door Panel / Panel Up to 00 mm x 80 mm (16,000 mm ) Up to 50 mm x 180 mm (45,000 mm ) Up to 330 mm x 00 mm (66,000 mm ) Threaded or plain entries in door panel / panel without window, as above. Note 1 & Window openings in front flange up to 00 mm x 80 mm Comp A & 07 Enclosures Type 04 & Comp A Front Rear Front Rear (3,000 mm ) (3,000 mm ) 1 (16,000 mm ) Page 5 of 1

6 for Certificate No.: IECEx TSA X Issue No.: 1 Fitment Windows in front Door Panel / Panel Threaded or plain entries in front flange. Note 1 Threaded entries in end or common walls. Note 3 & 5 Flange mounted components to end walls (Cable coupling devices, blanking plates). Note 4 & 5 Trunking (end Panel). Note 6 & 7 Comp A & 07 Enclosures Type 04 & Comp A Front Rear Front Rear (1,000 mm ) 1 (1,000 mm ) 30 mm ) 14 mm ) 3 mm ) mm ) 3 mm ) mm ) 3 mm ) mm ) 30 mm ) 14 mm ) 13 (41,000 mm ) 6 (41,000 mm ) 9 (30,300 mm ) 4 (30,300 mm ) 3 mm ) mm ) (4,300 mm ) 3 (4,300 mm ) Note: For detailed information on the above Table refer to Notes 1 to 7 in Schedule 4. Page 6 of 1

7 for Certificate No.: IECEx TSA X Issue No.: 1 Equipment construction and use restrictions. Schedule 5. Documentation supplied with each AFE00 Series enclosure or assembly of enclosures shall: o Identify the position, size and type of each cable entry. Where these are threaded entries, the type of thread is to be specified. o Provide an instruction manual, customised to the specific application. Ex certified components shall be installed in accordance with their respective conditions/limitations of certification. Internal components are to be assembled so as to provide adequate space between components, and between components and sidewalls, to reduce the possibility of hot spots. The selection and positioning within the enclosure of heat dissipating components shall prevent the temperature of the enclosure, or parts of the enclosure, exceeding the maximum service temperature of any surface or other component that completes the enclosure. In general: o o o o 150 ºC for the external surfaces of the enclosure generally; 75 ºC for the mounting point of any restrained receptacle or adaptor; 75 ºC for the mounting point of any cable gland; and 75 ºC for the mounting surround of any polycarbonate window or the lens itself. The selection, rating and positioning within the enclosure of heat dissipating components shall prevent the rated ambient conditions of Ex equipment (eg Ex barrier, Ex associated equipment, etc.) being exceeded. The enclosures shall not contain a general battery derived supply. Installed equipment may include cells or batteries but only those certified as Intrinsically Safe and suitable for use in this kind of enclosure and not intended to be charged in the Ex d enclosure. Use of these batteries is limited for memory back up only. Internal equipment and mounting plates shall be arranged in such a manner that at least 0% of each plane crosssection area is free to permit unimpeded gas flow, to preclude pressure piling. This area may be a summation of areas with a minimum dimension of 1.5 mm in any direction. Where fitted, bushing type sockets shall have a threaded connection equivalent to the stopping plugs covered by certificate IECEx TSA U and shall contain only circuits that comply with IEC External, nonwelded, joints of enclosure parts that are potentially in parallel, or form part of earth circuits, (such as adaptor or receptacle flanges) must be crossbonded. Each enclosure shall be subjected to a routine overpressure test, with a minimum test pressure as shown in below table and duration of application of overpressure minimum of 10 seconds and not exceeding 60 seconds. The enclosure may be tested empty, but must include all fitted components that are not themselves exempt from routine testing. Page 7 of 1

8 for Certificate No.: IECEx TSA X Issue No.: 1 Enclosure type Minimum test pressure (kpa) 01A* 1075 kpa 01B** 1075 kpa kpa kpa kpa kpa kpa kpa 30A* 30B** 1075 kpa 1075 kpa kpa kpa Note: * Denotes Auxiliary Chamber and ** denotes Main Chamber Drawings pertaining to Issue 0 of this Certificate: Drawing / Document No.: Page/s: Title: Revision Level: Date: (yyyymmdd) AFE00_1 1 Ampcontrol Series AFE00 Flameproof Enclosures Fitting and Machining Details AFE00_ 1 Ampcontrol Series AFE00 Flameproof Enclosures Fitting and Machining Details AFE00_3 1 Ampcontrol Series AFE00 Flameproof Enclosures Fitting and Machining Details AFE00_4 1 Ampcontrol Series AFE00 Flameproof Enclosures Fitting and Machining Details G C A AFE001 1 Design Brief for Flameproof Enclosures AFE00 1 Flameproof Enclosure Door / Flange Flamepath Details AFE003 1 Flameproof Enclosure Drilling Detail AFE004 1 Flameproof Enclosure Cable Coupling Devices Mounting Details AFE005 1 Flameproof Enclosure Transformer Trunking Flange Page 8 of 1

9 for Certificate No.: IECEx TSA X Issue No.: 1 Drawing / Document No.: Page/s: Title: AFE100 1 AFE000 series Control, Monitoring and Distribution Typical components & Single Line Revision Level: Date: (yyyymmdd) AFC014 1 Interlocking Arrangement Options AFC050 1 Flameproof Windows F AFC080 1 Typical FLP Tags & Identification Label H AFC090 1 AFE100 Series transformer bushing/ plate Conditions of Certification pertaining to Issue 0 of this Certificate: 1. It is special condition of safe use that, the precautions necessary to avoid the risk from electrostatic discharge from any polycarbonate window fitted to an enclosure shall be applied in accordance with the manufacturer s instructions for the equipment. It is specific condition of safe use that, for any IECEx certified Ex component fitted to the enclosure, the original manufacturer of the Ex component shall be contacted for information relating to the dimensions of flameproof joints. Variations pertaining to Issue 1 of this Certificate: Schedule of Variations 1. Option to weld ATF Series 170 enclosure to the external wall or door of the AFExxx Series enclosures.. Option to include mounting bosses through wall of enclosure. 3. Maximum aperture dimensions for cable coupling devices aligned with AS/NZS 199:009 and AS/NZS 1300: Increased number of threaded entries that may be provided with a trunking facility. 5. Increased number of threaded or plain entries in door panel without windows (0, 03, 07, 04, 06, 40, 90 enclosures). 6. Increased number of threaded or plain entries in front flange (03 enclosure). 7. Addition of new enclosure AFE Addition of new manufacturing location of Ampcontrol UK Ltd. 9. Minor editioral changes to some drawings. Schedule 6. Type and number of apertures for components walls / door panel. (Refer to next page) Page 9 of 1

10 for Certificate No.: IECEx TSA X Issue No.: 1 Enclosure AFE00 Series Type and Number of Aperture for components Fitment Windows in front Door Panel / Panel Up to 00 mm x 80 mm (16,000 mm ) Up to 50 mm x 180 mm (45,000 mm ) Up to 330 mm x 00 mm (66,000 mm ) Threaded or plain entries in door / panel without window, as above. Note 1 & Window openings in front flange up to 00 mm x 80 mm Threaded or plain entries in front flange. Note 1 Threaded entries in end or common walls. Note 3 & 5 Flange mounted components to end walls (Cable coupling devices, blanking plates). Note 4 & 5 Trunking (end Panel). Note 6 & 7 Comp A Note: For detailed information on the above Table refer to Notes 1 to 7 in Schedule 4. Enclosure Type Front Rear Front Rear (3,000 mm ) (3,000 mm ) (3,000 mm ) (3,000 mm ) (3,000 mm ) (3,000 mm ) 1 (16,000 mm ) (1,000 mm ) 1 (1,000 mm ) 30 mm ) 14 mm ) 3 mm ) mm ) 3 mm ) mm ) 3 mm ) mm ) 3 mm ) mm ) 30 mm ) 14 mm ) 3 mm ) mm ) 3 mm ) mm ) 13 (41,000 mm ) 6 (41,000 mm ) 9 (30,300 mm ) 4 (30,300 mm ) 3 mm ) mm ) (4,300 mm ) 3 (4,300 mm ) Page 10 of 1

11 for Certificate No.: IECEx TSA X Issue No.: 1 Schedule 7. For equipment construction and use restrictions Schedule 5 applies, except as varied in the following table. Enclosure type AFE Enclosure empty volume (L) Minimum test pressure (kpa) 01A* B** A* B** Note: * Denotes Auxiliary Chamber and ** denotes Main Chamber Drawings pertaining to Issue 1 of this Certificate: Drawing/Document No.: Page/s: Title: Revision Level: Date: (yyyymmdd) AFC080 1 Typical FLP Tags and Identification Label I AFE001 1 Design Brief for Flameproof Enclosures (Referred to as General Notes) AFE003 1 Flameproof Enclosure Drilling Detail 0049 AFE004 1 Flameproof Enclosure Cable Coupling Devices Mounting Details AFE006 1 ATF170 Enclosure Welded to AFExxx Series Enclosure AFE00_1 1 Ampcontrol Series AFE00 Flameproof Enclosures Fitting & Machining Details AFE00_4 1 Ampcontrol Series AFE00 Flameproof Enclosure Fitting & Machining Details I A Page of 1

12 for Certificate No.: IECEx TSA X Issue No.: 1 Conditions of Certification pertaining to Issue 1 of this Certificate: All previous conditions still apply. Page 1 of 1

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 10.0014 Issue No.: 2 Equipment: The Series 1200 range of blanking plugs, reducers and conversions are manufactured from mild steel, stainless steel or brass alloy and are

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx CML 14.0034X Issue No:

More information

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No

ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR U SERIAL No ABTQ-110 rev 00 (Last review: 28 Aug 12) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH S RANGE ENCLOSURES IECEx SIR 05.0046U SERIAL No 20 TYPE SX Ex e II C Gb Ex tb IIIC Db IP6* IECEx SIR

More information

Operating Instructions

Operating Instructions Operating Instructions Light-metal Ex d enclosures / flameproof enclosure > 8265/0 Empty enclosure > 8265/4 Control panel, integrated in Ex e enclosure > 8265/5 Control panel Table of Contents 1 Table

More information

Conductor Bushings Series 8174

Conductor Bushings Series 8174 > Current lead-in for Ex d enclosures > 1 to 72 conductors combined in one current lead-in > Series screw-in plug-in > For voltages up to max. 1 V > For size conductor up to 7 mm 2 www.stahl.de 3163E The

More information

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS Government Approved Test Laboratory (Previously AIA) Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS ZEST

More information

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME)

INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) INTERNATIONAL ELECTROTECHNICAL COMMISSION (IEC) SCHEME FOR CERTIFICATION TO STANDARDS RELATING TO EQUIPMENT FOR EXPLOSIVE ATMOSPHERES (IECEx SCHEME) Title: Report from ExMC Working Group 2 - TGDs To: Members

More information

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical

More information

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT

METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES IEC COMPLIANT IEC 649 COMPLIANT METROSIL CURRENT TRANSFORMER PROTECTION UNIT (CTPU) ENCLOSURES INTRODUCTION Current transformer open circuit protection with reliability, flexibility and expertise built-in. Current Transformer

More information

Infrared Linescanners

Infrared Linescanners Thermal Imaging and Temperature Profiles for Continuous Process Monitoring and Quality Control HD Infrared Linescanners PROCESS & ANALYTICAL INSTRUMENTS Mountings and Accessories LSPHD Mountings and Accessories

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

Junction Boxes Series 8118

Junction Boxes Series 8118 > Enclosure in glass fibre reinforced polyester resin > 3 different sizes available with 4, 5 or as a junction box with integrated miniature fuse: 3 terminals and 1 miniature fuse 7 terminals and 1 miniature

More information

Operating Instructions

Operating Instructions Operating Instructions Ex d Enclosures in Light Metal / Flameproof Encapsulation > 8265/0 Empty Enclosure > 8265/4 controller, installed in Ex e enclosure > 8265/5 controller Contents 1 Contents 1 Contents...2

More information

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1.

E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10 E10. Cable gland Series 8161/7, 8161/8. Installation Equipment and Accessories E10/1. > Explosion protection type "Increased safety" > Degree of protection IP68 > Ex e and Ex i versions > Integrated blind plug (accessory) for closing unused cable glands > Cable diameter ranges from 1 to

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017

PTB Ex PT Scheme. Procedure Instruction of program Explosion Pressure - Test Round 2017 Procedure Instruction of program Explosion Pressure - Test Round 2017 Content 1 General Performance... 2 2 Measurand / Characteristic of interest... 2 3 Test Item and Configurations... 2 3.1 Components...

More information

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE

CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE CABLE ENTRIES IN HAZARDOUS AREAS CORRECT SELECTION, INSTALLATION AND MAINTENANCE Compiled by: Arthur Cameron NOT SO CORRECT SELECTION AND INSTALLATION OF CABLE GLANDS AND JUNCTION BOXES IN HAZARDOUS AREAS

More information

Certificate of Conformity

Certificate of Conformity Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocols:

More information

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA

Single-Phase Pad-Mounted Distribution. Single-Phase Pad-Mounted Distribution Transformers KVA 62-10 Single-Phase Pad-Mounted Distribution Catolog Transformers Section Howard Industries, Inc. Certifi ed to ISO 9001:2015 62-10 Single-Phase Pad-Mounted Distribution Transformers 5-500 KVA 10002179

More information

Further technical information is available on

Further technical information is available on 1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,

More information

Check with local zoning official for property line distance requirements.

Check with local zoning official for property line distance requirements. RESIDENTIAL POOL PLAN SUBMITTAL GUIDELINES The following guidelines are intended to assist municipal residents with the permit acquisition process with regard to pools, spas and hot tubs for single family

More information

@h..p. lntertek. IECEx Certificate of Conformity

@h..p. lntertek. IECEx Certificate of Conformity ECEx Certificate of Conformity NTERNATONAL ELECTROTECHNCAL COMMSSON EC Certification Scheme for Explosive Atmospheres for rules and details of the ECElC Scheme visit www.iecex.com Certificate No.: { ECclC

More information

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) Stainless steel and plastic enclosures for use in potentially explosive environments R Rittal system partners Perfect

More information

Magnetic level switch type MR783 Instruction Manual

Magnetic level switch type MR783 Instruction Manual Magnetic level switch Magnetic level switch type MR783 1. DESCRIPTION page 3 1.1 Operation page 3 1.2 Application page 3 1.3 Description page 3 2. SPECIFICATIONS page 3 2.1 Service Conditions page 4 2.2

More information

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031)

IEC April Authorized Sole Agent : PT. Wisma Niagatama Perkasa. Phone : (031) Fax. : (031) IEC 62271-200 April 2004 Authorized Sole Agent : PT. Wisma Niagatama Perkasa Phone : (031) 5041242 Fax. : (031) 5044580 IEC 62271-200 Introduction Scope This standard specifies requirements for factory-assembled

More information

CATALOGUE // The Fort Vale Range of Equipment to suit Hydrogen Peroxide Tank Specification. Fort Vale Engineering Ltd. 2009

CATALOGUE // The Fort Vale Range of Equipment to suit Hydrogen Peroxide Tank Specification. Fort Vale Engineering Ltd. 2009 CATALOGUE // 20 19 18 16 17 The Fort Vale Range of Equipment to suit Hydrogen Peroxide Tank Specification 15 14 Fort Vale Engineering Ltd. 2009 THIS PAGE IS INTENTIONALLY BLANK HYDROGEN PEROXIDE EQUIPMENT

More information

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review) Certificate Number: MASC MS/11-127X Issue: 09 October 2017 Expire: 09 October 2020 Page: 1 of 5 IA CERTIFICATE (Annual review required by MASC covered by an additional letter) (Revision 2- Review & Review)

More information

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6

2-1- Shipping Receiving Lifting Location on Site Installation Stages 6 NEUTRAL GROUNDING RESISTORS INSTALLATION, OPERATION & MAINTENANCE MANUAL Contents 1- SAFETY INSTRUCTIONS... 3 1-1- Compliance with Instructions in this Manual. 3 1-2- Guidance Notes Installation.... 3

More information

L230 LED 40 Watt Searchlight

L230 LED 40 Watt Searchlight User Instruction & Installation Manual L230 LED 40 Watt Searchlight Product Reference Number: A6158 12/24v DECK A6159 12/24v CABIN Manufacturer s details: Francis Searchlights Ltd Union Road, Bolton Lancashire,

More information

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15

Project: Consultant : MEP Contractor: PREPARED BY: DORMAN SMITH SWITCHGEAR - DUBAI REVIEWED BY CONSULTANT : Page 1 of 15 PRCEDURES FR RUTINE TESTING F CAPACITR BANKS Consultant : MEP Contractor: Project: PREPARED BY: DRMAN SMITH SWITCHGEAR - DUBAI NAME: REVIEWED BY CNSULTANT : NAME: SIGNATURE: SIGNATURE: Page 1 of 15 Table

More information

Manual Power relay SR853

Manual Power relay SR853 Manual Power relay SR853 Rev. 0 SR853 manual page2 Safety Guidelines for explosion proof devices Application and Standards This instruction manual applies to explosion protected control systems of protection

More information

Arran LED Floodlight Luminaire

Arran LED Floodlight Luminaire Arran LED Floodlight Luminaire INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Important: Please read these instructions carefully before installing or maintaining this equipment. Good electrical

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A

More information

The evolution of the Ex-proof flame path

The evolution of the Ex-proof flame path April 2017 The evolution of the Ex-proof flame path As written in previous dissertation, the most critical part of a flameproof enclosure 'Ex d' is the flame path. Although the Standards are divided into

More information

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times.

ECP Series Explosionproof Enclosures for OEM Applications. Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures for OEM Applications Optimized design, extensive sizes, and fast lead times. ECP Series Explosionproof Enclosures, the latest addition to our portfolio of electrical

More information

3M InCa Individual Cross-Connection Cabinets

3M InCa Individual Cross-Connection Cabinets 3M InCa Individual Cross-Connection Cabinets InCa 7/14 InCa 7/12 InCa 7/10 InCa 7/8 InCa 8/14 InCa 8/12 InCa 8/10 InCa 8/8 InCa 10/14 InCa 10/12 InCa 10/10 InCa 10/8 Series 7 Series 8 Series 10 87 The

More information

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE

OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE OEM Manual MODEL 2305 ECONOMICAL DIGITAL SINGLE CYLINDER SCALE 1 These instructions generally describe the installation, operation, and maintenance of subject equipment. The manufacturer reserves the right

More information

Certificate of Conformity

Certificate of Conformity Certificate of Conformity Certificate Holder: CCG Cable Terminations (PTY) LTD 33 37 Forge Road Spartan Industrial Area, Kempton Park 1619 SOUTH AFRICA Electrical Apparatus: A2F, A2FX, and A2FCG Cable

More information

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008

INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008 INSTALLATION INSTRUCTIONS PUSH BAR PULLMAN PANIC BOLT DEVICE TO EN 1125 : 2008 0376/448/00 ISSUE 01 EMERGENCY PUSH PAD PULLMAN BOLT DEVICE TO EN 179 : 2008 1000mm MAXIMUM CLEAR OPENING HEIGHT WITH PUSH

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets)

enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) lri030784900.eps lri031083400.eps enclosures to ATEX and enclosures for special custom design (EEx p and NEMA cabinets) fri040466500.eps Stainless steel and plastic enclosures for use in potentially explosive

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design technical informations Material - Hinge body: self-extinguish high-rigidity SUPER-technopolymer, black colour. Resistant to solvents,

More information

GV Standard X-Vent. Setup, Commissioning & Installation Guide

GV Standard X-Vent. Setup, Commissioning & Installation Guide GV Standard X-Vent Setup, Commissioning & Installation Guide Technical experts in the design, manufacture and supply of precision engineered, architectural rooflights for residential and commercial buildings.

More information

44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES

44 CE RANGE WATERTIGHT SURFACE-MOUNTING JUNCTION BOXES WALL BOXES IN GWPLAST 75 - GWT 650 C GWT 650 C TP 85 C WALLS WITH CABLE GLAND - IP44 AND IP55 GW44001 JUNCTION BOXES WITH PLAIN PRESS-ON LID - IP44 - GREY RAL 7035 LxHxD (mm) No. holes / Ø GW 44 001 Ø

More information

NEW TYPE M PRESSURE RELIEF DEVICE

NEW TYPE M PRESSURE RELIEF DEVICE NEW TYPE M PRESSURE RELIEF DEVICE M PRESSURE RELIEF DEVICE ACCORDING TO EN 50216-5/A2 PATENTED 2 PRESSURE RELIEF DEVICE TYPE 50 M Section A-A 170 139 Transformer tank F 41.5 3 ø48.3 ø166 A P.R.D. TAG A

More information

Baying and lifting. Whitepaper

Baying and lifting. Whitepaper Baying and lifting Whitepaper Table of contents Introduction... 4 Enclosures baying... 6 Floor standing enclosures... 8 Side to side baying... 8 Internal baying brackets CCI06... 8 External baying brackets

More information

Residential Swimming pools

Residential Swimming pools City of Republic Community Development Department Residential Swimming pools REVISION DATE: JANUARY 2017 Swimming Pool Safety Definitions: Barrier Requirements: A) Application All swimming pools over 24

More information

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection SPOOL VALVES pilot operated single/dual solenoid (mono/bistable function) ISO 07-8 mm - pad mounting body M connection x/ - / - / Series 0 ISO 07- (8 mm) FEATURES M connection on top of valve: reduces

More information

WHEATLEY Series 500 Swing Check Valve

WHEATLEY Series 500 Swing Check Valve Document Number: TC003001-13 Revision: 02 WHEATLEY Series 500 Swing Check Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS...3 SCOPE...5 INSTALLATION AND OPERATION

More information

Continental Industries STEEL SERVICE TEES or FAX Visit

Continental Industries STEEL SERVICE TEES or FAX Visit Continental Industries STEEL SERVICE TEES 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

Engineering Data Sheet

Engineering Data Sheet Page 1 of 6 CE MARKING AND THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC Valves must be installed into a well designed system and it is recommended that the system be inspected in accordance with the appropriate

More information

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................

More information

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E

User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] IM 01C25A00-12E User s Manual EJX/EJA-E Series NEPSI Certification [Option code: /NF2, /NS21, /NS24 and /NS25] 12th Edition 1 1. Introduction Thank you for purchasing the DPharp electronic pressure transmitter. This manual

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

EXH. Specifications. Descriptions. Min. working pressure MPa

EXH. Specifications. Descriptions. Min. working pressure MPa Functional explanation Primary pressure flowed from passes through check valve on side, and flows in chamber A and B. Primary pressure also passes through pressure adjustment section and switching valve,

More information

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and

Bulletin Swimming pool, hot tub and spa installations Rules , , , , , and Bulletin 68-7-11 Swimming pool, hot tub and spa installations Rules 68-000, 68-056, 68-058, 68-064, 68-068, 68-302 and 68-404 Scope (1) Swimming pools - general (2) Grounding & bonding (a) Bonding for

More information

UHrasonic Sensor VEGASON60 type series SN6*.CI**H***

UHrasonic Sensor VEGASON60 type series SN6*.CI**H*** Certificate No.: IECEx PTa 06.0099X Issue No.: 0 Status: Current Date of Issue: 2006-12-27 Page 1 of 3 Applicant: VEGA Grieshaber KG Am Hohenstein 113 77761 Schiltach Germany Electrical Apparatus: Optional

More information

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS

GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS GAS DISTRIBUTION PRODUCTS TRANSITION FITTINGS CONTINENTAL INDUSTRIES, INC. The Ultimate Connection CONTINENTAL INDUSTRIES, INC. ABOUT US THE ULTIMATE CONNECTION Our Company Continental Industries, Inc.,

More information

M2 Antenna Systems, Inc. Model No: VLP16

M2 Antenna Systems, Inc. Model No: VLP16 M2 Antenna Systems, Inc. Model No: 100-600VLP16 SPECIFICATIONS: Model... 100-600VLP16 Frequency Range... 100-600 MHz Cont. *Gain... 9.64 dbi Front to back... 12 db Typical Beamwidth... E=64 / H=70 Feed

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS IAPMO GUIDE CRITERIA FOR WATER HEATER SUPPLY SHUTOFF VALVE WITH A / THERMAL EXPANSION CONTROL VALVE IGC 128-2006a8 1. PURPOSE 1.1 The purpose

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

Flow controller Type ED/CCB311 Instruction manual

Flow controller Type ED/CCB311 Instruction manual Flow measurement Flow controller Type ED/CCB311 1. GENERAL DESCRIPTION page 4 2. DETAILED DESCRIPTION page 4 3. PIPE - EXPLOITATION page 5 4. PREVENTIVE MAINTENANCE page 5 5. REPLACEMENT OF THE CONTACT

More information

PART I. GENERAL REQUIREMENTS FOR PERMANENTLY INSTALLED POOLS, STORABLE POOLS, OUTDOOR SPAS, OUTDOOR HOT TUBS, OR FOUNTAINS

PART I. GENERAL REQUIREMENTS FOR PERMANENTLY INSTALLED POOLS, STORABLE POOLS, OUTDOOR SPAS, OUTDOOR HOT TUBS, OR FOUNTAINS The overriding concern of Article 680 is to keep people and electricity separated. Some ways in which Article 680 accomplishes this include: References to other articles. Equipment Requirements. Any equipment

More information

EX-RECESSED CEILING LIGHT FITTINGS

EX-RECESSED CEILING LIGHT FITTINGS EX-RECESSED CEILING LIGHT FITTINGS RLF/RLF-INOX 250 18-58 W / RLF/RLF-INOX 250... N 18-36 W Metallic design for Zone 1 and Zone 21 The RLF... explosion-protected recessed ceiling light fittings with electronic

More information

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations.

C&G 2395 Exam Paper June Section A-All questions carry equal marks. Answer all three questions. Show all calculations. C&G 2395 Exam Paper June 2013 Section A-All questions carry equal marks. Answer all three questions. Show all calculations. 1. The electrical installation in an industrial unit is scheduled for a periodic

More information

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry

Operating Instructions for Intrinsically Safe Pressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Operating Instructions for Intrinsically Safe ressure Transmitters Series DMG/******** for Hazardous Application in Coal Mining Industry Contents 1. Introduction 2. Abbreviations, symbols 3. Important

More information

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS

ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS Annex 3, page 2 ANNEX AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE) CHAPTER 15 INERT GAS SYSTEMS The text of existing chapter 15 is replaced by the following: "1 Application This

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

THIS DOCUMENT SHOULD STAY WITH THE PUMP UNIT AT ALL TIMES!

THIS DOCUMENT SHOULD STAY WITH THE PUMP UNIT AT ALL TIMES! VERDERMAG Global PC 160L/M/H Maintenance Manual THIS DOCUMENT SHOULD STAY WITH THE PUMP UNIT AT ALL TIMES! TO BE READ IN CONJUNCTION WITH MAINTENACE MANUAL Page 1 of 16 Index 1.0 DOCUMENTATION 1.1 Type

More information

Gas density monitor With integrated transmitter Model GDM-100-TI

Gas density monitor With integrated transmitter Model GDM-100-TI SF 6 gas solutions Gas density monitor With integrated transmitter Model GDM-100-TI grid Products WIKA data sheet SP 60.05 for further approvals see page 5 Applications Gas density monitoring of closed

More information

AWWA Pipe Flanges. AWWA C Standard Steel Hub Flanges Class D AWWA C Standard Steel Hub Flanges Class E AWWA C Flange Manufacturer

AWWA Pipe Flanges. AWWA C Standard Steel Hub Flanges Class D AWWA C Standard Steel Hub Flanges Class E AWWA C Flange Manufacturer WW Pipe Flanges WW Flanges are commonly used in waterworks, wastewater, slurry, plant piping or other light duty applications generally requiring pressures of less than 300 psi. Pressure ratings for WW

More information

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual

WHEATLEY WHEATLEY SERIES 500 SWING CHECK VALVE. Installation, Operation and Maintenance Manual WHEATLEY SERIES 500 SWING CHECK VALVE STANDARD INTEGRAL SEAT & OPTIONAL REMOVABLE SEAT 2" FP - 6" FP 150# - 1500# 8" FP - 12" FP 150# - 900# API 6D and B16.34 2" FP - 4" FP 5000# DRILLING PRODUCTION VALVE

More information

Digital Melting Point Apparatus

Digital Melting Point Apparatus Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature

More information

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85

Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 XA01537F-A/00/EN/01.16 71333275 Products Solutions Services Safety Instructions Liquiphant FailSafe FTL80, FTL81, FTL85 0Ex ia IIC T6 Ga X Ga/Gb Ex ia IIC T6 X Document: XA01537F-A Safety instructions

More information

RTD temperature probes

RTD temperature probes RTD temperature probes Ex i for use in areas with an explosion hazard (Ex areas) Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel Operating

More information

Extra wide viewing angle from single indicator lamp. Lenses made from polycarbonate and hardened glass. 10mm Panel Hole.

Extra wide viewing angle from single indicator lamp. Lenses made from polycarbonate and hardened glass. 10mm Panel Hole. NORDIC N5 Headlamp The N5 integrates head light, indicator and park light in one assembly. This heavy duty light incorporates an adaptable single bolt mount featuring over 1 o of adjustment. ADR compliant

More information

XCE: Explosionproof Control Enclosures

XCE: Explosionproof Control Enclosures XCE SERIES XCE: Explosionproof Control Enclosures FEATURES 64 standard sizes available Pre-drilled for hinges (hinges optional) Pre-drilled for sub-panel (sub-panel optional) One-piece, NEMA 4 water-tight

More information

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108

AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 AWWA C504 COMPLIANT VALVES FROM 3 THRU 108 PO Box 411 Berwick PA 18603 800-247-VALV www.crispinvalve.com 500 SERIES: Sizes 3-20 Available The K-Flo 500 Series is a heavy-duty resilient seated butterfly

More information

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD.

VERSION 1 SUMP PUMP PIT UNIT KAWAMOTO PUMP ASIA CO.,LTD. SUMP PUMP PIT UNIT FEATURES All needed parts are assembled and united as a sump pit and easy to install for short period. Sump tank is made of SUS with epoxy coating and pipe is integrated by stainless

More information

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

INSTALLATION, OPERATION AND MAINTENANCE GUIDE INSTALLATION, OPERATION AND Placement in Pipeline System When installing Process Development & Control s ElastoTITE Elastomer-Hinged Check Valves in a pipeline, a minimum of five pipe diameters should

More information

PART 3 HULL INTEGRITY AND ARRANGEMENT

PART 3 HULL INTEGRITY AND ARRANGEMENT PART 3 HULL INTEGRITY AND ARRANGEMENT PART 3 HULL INTEGRITY AND ARRANGEMENT SECTION SUBJECT 3.1 General 3.2 Doors, hatchways and covers 3.3 Air pipes 3.4 Ventilators 3.5 Side scuttles (portholes) and

More information

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9

BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 BA307C & BA308C Intrinsically safe loop-powered 3½ digit panel mounting indicators issue 9 Issue: 9 22 nd March 2013 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate

More information

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No.

IECEx Cert f cate of Gonform ty. IECEX SIR ' X issue No.:1 9-e j{ca!ells_tgryi _ lssue No. 1 ( ) lssue No. IECEx Cert f cate of Gonform ty INTERNATIONAL ELECTROTECHNIGAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.tecex.com Certificate No.

More information

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY

GOST R CERTIFICATION SYSTEM FEDERAL AGENCY OF TECHNICAL REGULATION AND METROLOGY CERTIFICATE OF CONFORMITY CERTIFICATE OF CONFORMITY No. ROSS US.GB05.V03061 Valid from 8/12/2010 through 8/12/2013 No. 0422555 CERTIFICATION AGENCY ROSS RU.0001.11GB05 NONPROFIT INDEPENDENT RESEARCH ORGANIZATION (), CERTIFICATION

More information

Horizontal Bladder Tanks

Horizontal Bladder Tanks DATA SHEET Horizontal Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection SG33KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG33KTL-M. In no case shall this guide substitute for the user manual or related notes on

More information

Torque Tube TB300 Digital Transmitters

Torque Tube TB300 Digital Transmitters Page 1 of 7 7E.300-E Issue 4-2009 Description Series TB300 torque tube liquid level instruments utilize the buoyancy exerted on a displacer when immersed in a liquid. The buoyancy on the displacer is proportional

More information

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42

More information

Mini-Mac Applicator Specification Sheet Part No (Replaces )

Mini-Mac Applicator Specification Sheet Part No (Replaces ) Mini-Mac Applicator Specification Sheet Part No. 63801-2900 (Replaces 19814-1000) FEATURES ΠQuick set-up time; plus the crimp height, track and feed adjustments can be preset in applicator ΠConductor

More information

Continental Industries TRANSITION FITTINGS or FAX Visit

Continental Industries TRANSITION FITTINGS or FAX Visit Continental Industries TRANSITION FITTINGS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and

More information

4/2 way Pneumatic Solenoid Valve

4/2 way Pneumatic Solenoid Valve 4/2 way Pneumatic Solenoid Valve Compact design Push-over solenoid coil Exhaust air can be regulated Tube, threaded and sub-base connections Type combined with Seat valve version Type 2508 Type 2510/11

More information

Vertical Bladder Tanks

Vertical Bladder Tanks DATA SHEET Vertical Bladder Tanks Features UL Listed and FM Approved for use with various ANSUL proportioners and foam concentrates 175 psi (12.1 bar) maximum allowable working pressure (design pressure)

More information

VG5 Supplementary instructions

VG5 Supplementary instructions VG5 Supplementary instructions 2-wire / 10 GHz Radar (FMCW) Level Meter Supplementary Instructions for ATEX applications HYCONTROL CONTENTS VG5 1 General safety information 4 1.1 Scope of the document...

More information

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

KTM OM-2 SPLIT BODY FLOATING BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood SECTION 1 - STORAGE 1.1 Preparation and preservation for storage All valves should be properly packed in order to protect the parts

More information

GENERAL APPLICATION NOTES

GENERAL APPLICATION NOTES GENERAL APPLICATION NOTES There are common considerations when using our connectors. Additional considerations may apply based on the particular connector being used, the application, and conditions in

More information

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar)

Assembly instruction. Operating temperature range -60 C +85 C Protection. IP 66, 67, 68 (5 bar) Assembly instruction 1 2 3 4 5 6 7 1. Entry Component 2. Compound Sleeve 3. Interlocking Armour Cone 4. Armour Clamping Ring 5. Gland Body 6. Outer Sheath Sealing 7. Dome Nut 8. Compound 8 Operating temperature

More information

Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual

Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual Model 10E Enviro-Line Environmental Pressurization System Installation & Operation Manual Table of Contents Table of Contents Page 2 Purpose and Description Page 8 Dimensions Page 2 Page 3 Identifying

More information

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI

1 Overview. Pressure Measurement Single-range transmitters for general applications. 1/22 Siemens FI Siemens AG 06 SITRANS LH00 Transmitter for hydrostatic level Overview Function U const. p U I EM The pressure transmitter SITRANS LH00 is a submersible sensor for hydrostatic level measurement. The pressure

More information

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50

CA46S Austenitic Stainless Steel Air and Gas Trap DN40 and DN50 Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information