IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

Size: px
Start display at page:

Download "IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For"

Transcription

1 IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Hongli Zhihui Group Co.,Ltd. No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou, China Report Type: 9000 Hours Test Report Product Type: LED Package Test Engineer: Daniel Duan Report Number: RSZ M2 Test Date: to Report Date: Reviewed By: Revised Note: Prepared By: Jeanne Han /EE Manager The previous report RSZ M1 is replaced by this report on Bay Area Compliance Laboratories Corp. (Dongguan). No.69,Pulongcun,Puxinhu Industrial Area, Tangxia, Dongguan, Guangdong, China. Tel: Fax: Note: The test data was only valid for the test sample(s). This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report is valid only with a valid digital signature. The digital signature may be available only under the Adobe software above version 7.0.

2 TABLE OF CONTENTS 1 - GENERAL INFORMATION DESCRIPTION OF LED LIGHT SOURCES STANDARDS USED: TEST FACILITY DESCRIPTION OF AUXILIARY EQUIPMENT OPERATING CYCLE AMBIENT CONDITIONS PHOTOMETRY MEASUREMENT UNCERTAINTY SAMPLE SET SUMMARY OF TEST RESULT TEST DATA DATA SET 1, 55 C, 60MA (LUMEN MAINTENANCE) DATA SET 1, 55 C, 60MA (CHROMATICITY SHIFT) DATA SET 2, 85 C, 60MA (LUMEN MAINTENANCE) DATA SET 2, 85 C, 60MA (CHROMATICITY SHIFT) DATA SET 3, 105 C, 60MA (LUMEN MAINTENANCE) DATA SET 3, 105 C, 60MA (CHROMATICITY SHIFT) APPENDIX A EUT PHOTO A.1 MECHANICAL DIMENSIONS (TA = 25 C) A.2 EUT PHOTO Report No. RSZ M2 Page 2 of 16 IESNA LM Test Report

3 1 - GENERAL INFORMATION 1.1 Description of LED Light Sources Devices tested Part Number: HL-A-2835HW-S1-08-HR3 Part Type: LED Package Nominal CCT: 2700K Power: 0.2W Current Density per LED die: 372mA/mm 2 Power Density per LED die: 1.24W/mm 2 CRI: 80 Die Spacing: N/A Family products covered by this report: According to ENERGY STAR Requirements for the Use of LM-80 Data, the following products can be covered by this report base on the information and declaration provided by manufacturer. The information of these models shows that the covered products meet all section 4 requirements of ENERGY STAR Requirements for the Use of LM-80 Data (September 28, 2017) This report covers the following models: Differences Items Testing Products Multiple Models Details HL-A-2835HW-S1-08-HR3(R9) HL-A-PU2835HW-S1-08-HR3 HL-A-PU2835HW-S1-08-HR3(R9) HL-A-2835HW-S1-08-PCT-HR3 HL-A-2835HW-S1-08-PCT-HR3(R9) Model Name HL-A- 2835HW- S1-08- HR3 HL-A-PU2835HW-S1-08-PCT-HR3 HL-A-PU2835HW-S1-08-PCT-HR3(R9) HL-AS-2835HW-S1-08-PCT-HR3 Only different Model name for different market HL-AS-2835HW-S1-08-PCT-HR3(R9) HL-AS-PU2835HW-S1-08-PCT-HR3 HL-AS-PU2835HW-S1-08-PCT- HR3(R9) HL-A-2835HW-S1-08L-HR3 HL-A-2835HW-S1-08HL-HR3 Report No. RSZ M2 Page 3 of 16 IESNA LM Test Report

4 Differences Items Testing Products Multiple Models Details HL-A-2835HW-S1-08L-HR3(R9) HL-A-2835HW-S1-08HL-HR3(R9) HL-A-PU2835HW-S1-08L-HR3 HL-A-PU2835HW-S1-08HL-HR3 HL-A-PU2835HW-S1-08L-HR3(R9) HL-A-PU2835HW-S1-08HL-HR3(R9) HL-A-2835HW-S1-08L-PCT-HR3 HL-A-2835HW-S1-08L-PCT-HR3(R9) HL-A-PU2835HW-S1-08L-PCT-HR3 HL-A-PU2835HW-S1-08L-PCT- HR3(R9) HL-AS-2835HW-S1-08L-PCT-HR3 HL-AS-2835HW-S1-08L-PCT-HR3(R9) HL-AS-PU2835HW-S1-08L-PCT-HR3 HL-AS-PU2835HW-S1-08L-PCT- HR3(R9) SL-*B2835FAB-11CA* SL-*B2835FAA-11CA* SL-*B2835FTA-11CA* Only different Model name for different market SL-*B2835FAB-11CA*H SL-*B2835FAA-11CA*H SL-*B2835FTA-11CA*H The first *is a letter I, N, W which stand for CCT: I means Below 3700K; N means K; W means More than 4700K SL-*B2835FAB-11CA*/* SL-*B2835FAA-11CA*/* SL-*B2835FTA-11CA*/* The second * is a different product solution (Color coordinate and applications and special solution etc ). SL-*B2835FAB-11CA*-* SL-*B2835FAA-11CA*-* The third * is different version numbers, Use Or ABC.... expression. SL-*B2835FTA-11CA*-* Report No. RSZ M2 Page 4 of 16 IESNA LM Test Report

5 Differences Items Testing Products Multiple Models Details SL-*B2835FAB-11CA*H/* SL-*B2835FAA-11CA*H/* SL-*B2835FTA-11CA*H/* SL-**B2835FTA-11CA***C-APH*** Only different Model name for different market. First **-designates nominal CCT (22=2200K,27=2700K,30=3000K, 35=3500K,40=4000K,50=5000K, 57=5700K,65=6500K) SL-**B2835FAA-11CA***C-APH*** Middle *** -designates nominal Different solution (Color coordinate and applications and special solution etc ) SL-**B2835FAB-11CA***C-APH*** Last *** -designates version numbers, Use expression. 1.2 Standards Used: IESNA LM-80-08: IES Approved Method for Measuring Lumen Maintenance of LED Light Sources. CIE 127:2007: Measurement of LEDs (This standard was not accredited by IAS) ENERGY STAR Requirements for the Use of LM-80 Data (This standard was not accredited by IAS) 1.3 Test Facility The testing facility used by Bay Area Compliance Laboratories Corp. (Dongguan). is located at No.69,Pulongcun,Puxinhu Industrial Area, Tangxia, Dongguan, Guangdong, China. 1.4 Description of Auxiliary Equipment Device Manufacture Model No Serial No Calibration date Calibration due date Integral Sphere EVERFINE Diameter 0.3m Programmable Test Power for LEDs High accuracy array spectroradiometer EVERFINE LED300E EVERFINE HAAS T Report No. RSZ M2 Page 5 of 16 IESNA LM Test Report

6 Device Manufacture Model No Serial No Calibration date Calibration due date Standard Light Source Precision digital stabilized DC power supply Multilayer aging machine Digital CC&CV DC Power Supply Digital CC&CV DC Power Supply Digital CC&CV DC Power Supply EVERFINE D EVERFINE WY605 G115987CJ BACL B EVERFINE WY EVERFINE WY EVERFINE WY Operating Cycle Samples are driven with a constant direct current (DC) 1.6 Ambient Conditions For lumen maintenance test, samples were operated in thermal chambers with minimal ambient airflow. For long term reliability test, the case temperature was controlled by mounting several thermocouples on a sample reliability stress board at the designated thermal measurement point, as shown in APPENDIX. The ambient temperature T A was measured by several thermocouples at a distance of 5 mm above the reliability test board. The relative humidity within chamber was less than 65%. For photometry measurement, temperature was set to 25 C ± 2 C, RH <65%. 1.7 Photometry Measurement Uncertainty The uncertainty of the light output measurements is U=1.59% (K=2), at the 95% confidence level. The uncertainty of the correlated color temperature measurements is U=21K (K=2), at the 95% confidence level. This calibration results traceable to the NATIONAL INSTITUTE OF METROLOGY (NIM). Report No. RSZ M2 Page 6 of 16 IESNA LM Test Report

7 1.8 Sample Set Sampling Method: LED samples for IESNA LM-80 testing consist of units built from a minimum of three manufacturing lots with each manufacturing lot built from different wafer lots built on non-consecutive days. These manufacturing lots are picked to represent a wide parametric distribution. Sample Size: Total 75Pcs; Each Ts test condition 25Pcs The samples tested at TS 55 C, TS 85 C and TS 105 C were received at and tested during to The samples were numbered from 1to 25, 26 to 50 and 51 to 75 Data Set 1: 55 C, 60mA Part Number: Number of Units: 25 Actual Case Temperature(T S): Actual Ambient Temperature(T A): Life Test Drive Current: Measurement Current: Data Set 2: 85 C,60mA Part Number: Number of Units: 25 Actual Case Temperature(T S): Actual Ambient Temperature(T A): Life Test Drive Current: Measurement Current: Data Set 3: 105 C, 60mA Part Number: Number of Units: 25 Actual Case Temperature(T S): Actual Ambient Temperature(T A): Life Test Drive Current: Measurement Current: HL-A-2835HW-S1-08-HR3 T S =54.1 C T A =51.9 C I F = 60mA I F = 60mA HL-A-2835HW-S1-08-HR3 T S =84.3 C T A =82.7 C I F =60mA I F = 60mA HL-A-2835HW-S1-08-HR3 T S =104.2 C T A =103.4 C I F = 60mA I F = 60mA Report No. RSZ M2 Page 7 of 16 IESNA LM Test Report

8 2 - SUMMARY OF TEST RESULT Data Set: Data Set 1, 55 C, 60mA Number of Units: 25 Failures Observed: 0 Test Interval and Test Duration: Average. Lumen Maintenance at 6000 hours: 97.47% Average Chromaticity Shift at 6000 hours ( u v ): Average. Lumen Maintenance at 9000 hours: 95.72% Average Chromaticity Shift at 9000 hours ( u v ): h,1000h,2000h,3000h,4000h,5000h,6000h, 7000h,8000h,9000h Reported TM-21 L 70 Lifetime: >54,000 hours Data Set: Data Set 2, 85 C, 60mA Number of Units: 25 Failures Observed: 0 Test Interval and Test Duration: Average. Lumen Maintenance at 6000 hours: 96.90% Average Chromaticity Shift at 6000 hours( u v ): Average. Lumen Maintenance at 9000 hours: 95.06% Average Chromaticity Shift at 9000 hours ( u v ): h,1000h,2000h,3000h,4000h,5000h,6000h, 7000h,8000h,9000h Reported TM-21 L 70 Lifetime: >54,000 hours Data Set: Data Set 3, 105 C, 60mA Number of Units: 25 Failures Observed: 0 Test Interval and Test Duration: Average. Lumen Maintenance at 6000 hours: 96.39% Average Chromaticity Shift at 6000 hours( u v ): Average. Lumen Maintenance at 9000 hours: 94.32% Average Chromaticity Shift at 9000 hours ( u v ): h,1000h,2000h,3000h,4000h,5000h,6000h, 7000h,8000h,9000h Reported TM-21 L 70 Lifetime: 53,000 hours Report No. RSZ M2 Page 8 of 16 IESNA LM Test Report

9 3 - Test Data 3.1 Data Set 1, 55 C, 60mA (Lumen Maintenance) No. VF(V) Φ(lm) Lumen Maintenance (%) 0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000h 8000h 9000h Ave Med st dev Min Max TM-21 Projection: Test Duration: 9000 hours Failures Observed: 0 α: 5.361E-06 β: Reported L70: >54,000hours Report No. RSZ M2 Page 9 of 16 IESNA LM Test Report

10 % Luminous Flux Company: Hongli Zhihui Group Co.,Ltd. 3.2 Data Set 1, 55 C, 60mA (Chromaticity Shift) No. u v CCT(K) Chromaticity Shift ( u v ) 0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000h 8000h 9000h Ave Med st dev Min Max % 105% 100% 95% 90% 85% 80% 75% 70% Flux u'v' Time (hours) Chromaticity Shift (Du'v') Report No. RSZ M2 Page 10 of 16 IESNA LM Test Report

11 3.3 Data Set 2, 85 C, 60mA (Lumen Maintenance) No. VF(V) Φ(lm) Lumen Maintenance (%) 0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000h 8000h 9000h Ave Med st dev Min Max TM-21 Projection: Test Duration: 9000 hours Failures Observed: 0 α: 5.756E-06 β: Reported L70: >54,000hours Report No. RSZ M2 Page 11 of 16 IESNA LM Test Report

12 % Luminous Flux Company: Hongli Zhihui Group Co.,Ltd. 3.4 Data Set 2, 85 C, 60mA (Chromaticity Shift) No. u v CCT(K) Chromaticity Shift ( u v ) 0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000h 8000h 9000h Ave Med st dev Min Max % 105% 100% 95% 90% 85% 80% 75% 70% Flux u'v' Time (hours) Chromaticity Shift (Du'v') Report No. RSZ M2 Page 12 of 16 IESNA LM Test Report

13 3.5 Data Set 3, 105 C, 60mA (Lumen Maintenance) VF(V) Φ(lm) Lumen Maintenance (%) No. 0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000h 8000h 9000h Ave Med st dev Min Max TM-21 Projection: Test Duration: 9000 hours Failures Observed: 0 α: 6.740E-06 β: Reported L70: 53,000 hours Report No. RSZ M2 Page 13 of 16 IESNA LM Test Report

14 % Luminous Flux Company: Hongli Zhihui Group Co.,Ltd. 3.6 Data Set 3, 105 C, 60mA (Chromaticity Shift) No. u v CCT(K) Chromaticity Shift ( u v ) 0hr(Initial) 1000hrs 2000hrs 3000hrs 4000hrs 5000hrs 6000hrs 7000h 8000h 9000h Ave Med st dev Min Max % 105% 100% 95% 90% 85% 80% 75% 70% Flux u'v' Time (hours) Chromaticity Shift (Du'v') Report No. RSZ M2 Page 14 of 16 IESNA LM Test Report

15 Appendix A EUT PHOTO A.1 Mechanical Dimensions (Ta = 25 C) TMP LED All dimensions are in millimeter A.2 EUT Photo Report No. RSZ M2 Page 15 of 16 IESNA LM Test Report

16 Report Revision Report Number Report Date Contents RSZ Original report. RSZ M Update the company name of Applicant. Update the Description of LED Light Sources in page 3. Add the Family Declaration in page 3 to page 5. RSZ M Update the Family Cover Model in page 3 to page 5. ***********END OF REPORT*********** Report No. RSZ M2 Page 16 of 16 IESNA LM Test Report

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For Guangzhou Hongli Opto-Electronic Co., Ltd. No.1, Xianke Yi Road, Huadong Town, Huadu District, Guangzhou,

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES. For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES. For. EiKO Global, LLC W 84th Street, Shawnee, KS 66227 IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For EiKO Global, LLC 23220 W 84th Street, Shawnee, KS 66227 Report Type: 9000 Hours Test Report Product Type:

More information

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For

IESNA LM MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT. For IESNA LM-80-2008 MEASURING LUMEN MAINTENANCE OF LED LIGHT SOURCES MEASUREMENT AND TEST REPORT For AUTLED GmbH zh Robert Sever,Resselstrasse 3,2120 Obersdorf,Austria Model:AUTLED 2835 CRI 90+ Report Type:

More information

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea

TEST REPORT. ACCORDING TO IES LM For. Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea TEST REPORT ACCORDING TO IES LM-80-2015 For Samsung Electronics Co., LTD. 1,Samsung-Ro,Giheung-Gu,Yongin-City,Gyeonggi-Do 17113, Korea Model: SPMWH1228xxxxxxxxx Report Type: 9000 Hours Test Report Product

More information

LM LUMEN MAINTENANCE TEST REPORT

LM LUMEN MAINTENANCE TEST REPORT Version: B LM-80-08 LUMEN MAINTENANCE TEST REPORT Company :UNISTARS Corporation Ltd. Sample Name :VENUS 3535 Sample Received :May 29 2012 Sample Tested :Feb 14 2013 TESTING LABORATORY IS ACCREDITED BY:

More information

OPTO Laboratory Testing Report

OPTO Laboratory Testing Report OPTO Laboratory Testing Report Report date: August 12, 2013 Edison Opto Laboratory Report Authorized Dept. : Authorized address: Testing sample: Edison Opto RD Department 4F, NO.800, Chung-Cheng Rd., Chung-Ho

More information

Photometric Test Report

Photometric Test Report Photometric Test Report Relevant Standards IES LM-79-2008 ANSI C82.77-10-2014 UL1598-2008 Prepared For Revolution Lighting Technologies, Inc 2280 Ward Ave. Simi Valley, CA. 93065 Roman Sukharev, (877)

More information

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide

UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide ABB MEASUREMENT & ANALYTICS PRODUCT GUIDE PG/SMD140 EN REV. B UKAS calibration laboratory 8809 Temperature, pressure and electrical signals calibration guide Measurement made easy UKAS calibration laboratory

More information

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0

HUMOR 20. High Accuracy Humidity Calibrator. Water T, p1 HUMOR 20 V1.0 High Accuracy Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated.

Vaisala Pressure, RH & Temp. Transmitter. The instrument was operational upon receipt. The instrument was adjusted and calibrated. Asset #: 123 Calibration - Certificate No: 2083.01 Customer: Condition: Action Taken: Sample Inc. 123 Sample Rd. Sample, MA 01234 The instrument was operational upon receipt. The instrument was adjusted

More information

QTi DALI/DIM / QTi GII / QTP5

QTi DALI/DIM / QTi GII / QTP5 osram.com T5 HO High Lumen Output T5 HO QTi DALI/DIM / QTi GII / QTP5 TECHNICAL INFORMATION 01 Benefits Impressive luminous flux High efficiency Very good luminous flux maintenance throughout the life

More information

LUMILUX T5 HO CONSTANT

LUMILUX T5 HO CONSTANT osram.com LUMILUX Constant Light output over a wider temperature range LUMILUX QTi DALI/DIM / QTi GII / QTP5 TECHNICAL INFORMATION 01 Benefits Impressive luminous flux at high and low ambient temperature

More information

PrevaLED Linear Slim 2

PrevaLED Linear Slim 2 www.osram.com/prevaled-linear PrevaLED Linear Slim 2 630lm, 1100lm, 2000lm on 280mm 2200lm, 4000lm on 560mm Dimension (l x w x h): 280mm x 20mm x 6mm 560mm x 20mm x 6mm Benefits LED module can be operated

More information

Table of Contents. Version 5.1. Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10

Table of Contents. Version 5.1. Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10 Version 5.1 Table of Contents Specifications 2-4 Technical Specs 2 Colors 3 Physical Specifications 4 Mounting Hardware 9-10 Aluminum 9 Plastic 9 Plastic & Aluminum 10 Part Number Naming Convention 5 Packaging

More information

QTi DALI/DIM / QTi GII / QTP5

QTi DALI/DIM / QTi GII / QTP5 osram.com T5 HE Good light output, efficiency and economy T5 HE QTi DALI/DIM / QTi GII / QTP5 TECHNICAL INFORMATION 01 Benefits Good economy and efficiency Up to 20% more efficient than Standard T8 Minimum

More information

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1

HUMOR 20 HUMOR 20. High-precision Humidity Calibrator. Water T, p1 High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

Light Lab. Reliable Measurements through Regular Calibration. DAkkS

Light Lab. Reliable Measurements through Regular Calibration. DAkkS Light Lab Reliable Measurements through Regular Calibration QM DAkkS ARS 85 EYREIENCEG QM EXP Benefits of Calibration PERFECTION THROUGH CALIBRATION RIN EASU HT M OLOGY IG L IN ECHN T LEGAL CERTAINTY Avoidance

More information

QT-FIT8 2X58-70/ VS20

QT-FIT8 2X58-70/ VS20 www.osram.com OSRAM DE LUXE lamps meet high demands in terms of color rendering Ideal for all applications in which color rendering plays an important role T8 DE LUXE QT-FIT8 2X58-70/220-240 VS20 1 Benefits

More information

2014 Programme of Training Courses in Measurement & Calibration

2014 Programme of Training Courses in Measurement & Calibration 2014 Programme of Training Courses in Measurement & Calibration NSAI National Metrology Laboratory offers public courses to help individuals gain the skills that they require in the field of Measurement

More information

FPG8601 Force Balanced Piston Gauge

FPG8601 Force Balanced Piston Gauge FPG8601 Force Balanced Piston Gauge Reference Level Calibration System for very low pressure Pressure range: 0 to 15 kpa gauge, absolute and absolute differential Standard resolution: 0.010 Pa, high resolution

More information

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

IDL01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05 IDL0 Battery Powered Precision Digital Gauge for Leak Testing Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger

More information

1224SUBC/C470/S400-A4

1224SUBC/C470/S400-A4 Features Choice of various viewing angles Available on tape and reel. Reliable and robust The product itself will remain within RoHS compliant version. Compliance with EU REACH Compliance Halogen Free.(Br

More information

Coda cx1 Thermal Cycle Test Procedure

Coda cx1 Thermal Cycle Test Procedure Coda cx1 Thermal Cycle Test Procedure CDL 1-TP07-0200:0209 MIT Ref. 85-01050.04 Revision 2.0 8 th June 2004 CDL 1-TP07-0200:0209 Contents 1 Introduction... 1 1.1 Activity Description... 1 2 Requirements...

More information

QTi DALI/DIM / QTi GII / QTP5

QTi DALI/DIM / QTi GII / QTP5 osram.com Reduce up to 10% of Energy usage even in existing systems QTi DALI/DIM / QTi GII / QTP5 TECHNICAL INFORMATION 01 Benefits Energy savings up to 10% compared to standard lamps Excellent economy

More information

DeFelsko PosiTector Dew Point Meter DPM & DPMD Probes

DeFelsko PosiTector Dew Point Meter DPM & DPMD Probes Management Procedure 2581 Revision: D Date Issued: November 9, 2007 Date Revised: April 19, 2017 Calibration Procedure DeFelsko PosiTector Dew Point Meter DPM & DPMD Probes Table of Contents 1 Introduction

More information

Beamex. Calibration White Paper. Weighing scale calibration - How to calibrate weighing instruments

Beamex. Calibration White Paper.  Weighing scale calibration - How to calibrate weighing instruments Beamex Calibration White Paper info@beamex.com Weighing scale calibration - How to calibrate weighing instruments Weighing scale calibration - How to calibrate weighing instruments Weighing scales, weighing

More information

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation

HUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according

More information

204-10SDRD/S530-A3 LAMP. Features. Description. Applications. Revision 1. LifecyclePhase: Expired Period: Forever. Choice of various viewing angles

204-10SDRD/S530-A3 LAMP. Features. Description. Applications. Revision 1. LifecyclePhase: Expired Period: Forever. Choice of various viewing angles Features Choice of various viewing angles Available on tape and reel. Reliable and robust Pb free The product itself will remain within RoHS compliant version. Description The series is specially designed

More information

DULUX L LUMILUX DE LUXE

DULUX L LUMILUX DE LUXE www.osram.com EXCELLENT COLOR RENDERING LUMILUX QTP - DL 2x55/220-240 GII 1 Benefits Impressive quality of light Extremly economical Excellent luminous flux Improved lumen maintenance Long service life

More information

LAMP 336SURSYGWS530-A3

LAMP 336SURSYGWS530-A3 Features Two chips are matched for uniform light output, wide viewing angle Long life-solid state reliability I.C. compatible/low power consumption The product itself will remain within RoHS compliant

More information

High-speed pressure sensor Model CPT6140

High-speed pressure sensor Model CPT6140 Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications

More information

DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC TECHNICAL INFORMATION 1.

DULUX L LUMILUX IMPROVED LIFETIME & SYSTEM GUARANTEE. DULUX L LUMILUX & QUICKTRONIC  TECHNICAL INFORMATION 1. www.osram.com IMPROVED LIFETIME & SYSTEM GUARANTEE QTP-M 1x26-42 TECHNICAL INFORMATION 1 Benefits Extremly economical Good quality of light Excellent luminous flux Improved lumen maintenance Long service

More information

TR Test Report Complementary Testing RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22)

TR Test Report Complementary Testing RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22) RKN e1 Container (+5 C) Protection by Insulation Version: 01 Page: 2 (22) Document History Version Date of issue Revision(s) Issued by 01 16OCT2012 N/A (First version of document) David Graaf, Envirotainer

More information

QT-FIT8 2X58-70/ VS20

QT-FIT8 2X58-70/ VS20 www.osram.com systems offer excellent lumen maintenance, high efficiency and impressive economy QT-FI 2X58-70/220-240 VS20 1 Benefits Up to 18% higher luminous efficacy than conventional BASIC lamps Good

More information

LED Modules. Fortimo LED Line High Flux PR. 2ft 4000lm 1R NA

LED Modules. Fortimo LED Line High Flux PR. 2ft 4000lm 1R NA LED Modules Fortimo LED Line High Flux PR 2ft 4000lm 1R NA Fortimo LED Line high flux performance (PR) is designed to provide top performance for high lumen and high temperature applications such as high-bay

More information

LAMP SUGC/S400-A5

LAMP SUGC/S400-A5 Features Choice of various viewing angles Available on tape and reel. Reliable and robust Pb free The product itself will remain within RoHS compliant version. Compliance with EU REACH Compliance Halogen

More information

333-2SURC/H3/S530-A4 LAMP. Features. Description. Applications. 1 Ver.:2 Release Date:12/13/2016 狀態 :Approved( 正式發行 )

333-2SURC/H3/S530-A4 LAMP. Features. Description. Applications. 1 Ver.:2 Release Date:12/13/2016 狀態 :Approved( 正式發行 ) Features Choice of various viewing angles Available on tape and reel. Reliable and robust Pb free The product itself will remain within RoHS compliant version. Description The series is specially designed

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instruction and Maintenance Manual GRYF OXY ZM 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 www.gryf.eu ver.: 11.2.2015 OEM module

More information

LED Down Light (8 ) Dimension:

LED Down Light (8 ) Dimension: LED Down Light (8 ) Dimension: Specification Model No. LOR-DLC218R24F8-8 LOR-DLN218R24F8-8 LOR-DLW218R24F8-8 Input Voltage AC100-240V Rated Power 24W 24W 24W Luminous Flux 2040lm 1920lm 1800lm Luminous

More information

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing Ø

More information

EALP05RDBRA0 LAMP. Features. Description. Applications. Choice of various viewing angles. Available on tape and reel. Reliable and robust

EALP05RDBRA0 LAMP. Features. Description. Applications. Choice of various viewing angles. Available on tape and reel. Reliable and robust Features Choice of various viewing angles Available on tape and reel. Reliable and robust The product itself will remain within RoHS compliant version. Compliance with EU REACH Compliance Halogen free.

More information

DM01. Please visit our website: Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

DM01. Please visit our website:  Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05 DM0 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 00 mbar up to 0... 00 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

ChromaLit Extruded Linear

ChromaLit Extruded Linear ChromaLit Extruded Linear CL-XXX-LIN0-PC0 Series Product Overview Intematix Remote Phosphor light source will change the way you approach solid-state lighting design. ChromaLit offers beautiful light quality

More information

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. Type: ETd 04. class 0.05

ETd 04. Battery Powered Precision Digital Gauge. Stainless Steel Sensor.  Type: ETd 04. class 0.05 Battery Powered Stainless Steel Sensor class 0.05 Nominal pressure from 0 100 mbar up to 0... 400 bar Special characteristics modular sensor concept data logger graphic display stainless steel housing

More information

COSMO INSTRUMENTS CO., LTD.

COSMO INSTRUMENTS CO., LTD. Specification Sheet COSMO AIR LEAK TESTER ModelLS-1861 Meets SI Unit Requirement Improved accuracy with the new Master-Preset compensation feature Compensates for environmental changes Improves cycle time

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

Specification for Approval

Specification for Approval Specification for Approval ( Version 1.0 ) Part No. : LWH1036N comments LUXPIA Co., Ltd. Designed by Checked by Approved by Approved by Approved by Approved by / / / / / / Date :... Date :... LUXPIA CO.,LTD.

More information

UNDERSTANDING, ACCELERATED

UNDERSTANDING, ACCELERATED UNDERSTANDING, ACCELERATED MEASURE FLOW, PRESSURE, AND TEMPERATURE ALL IN ONE INSTRUMENT! Designed for Performance TSI thermal mass flowmeters incorporate a proprietary platinum film sensor design for

More information

LAMP 339-9SUGSURSUBC/S1174

LAMP 339-9SUGSURSUBC/S1174 Features High efficiency. Selected minimum intensities. Available on tape and reel. The product itself will remain within RoHS compliant version Compliance with EU REACH Compliance Halogen free. (Br

More information

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities

Specific Accreditation Criteria Calibration ISO IEC Annex. Mass and related quantities Specific Accreditation Criteria Calibration ISO IEC 17025 Annex Mass and related quantities January 2018 Copyright National Association of Testing Authorities, Australia 2014 This publication is protected

More information

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration

CTAG:b9927e36a4b3f34a9138ce0bb2426b22 Certificate of Calibration CTAG:b997e6abfa98cebb6b Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 79 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8

More information

Instruction and Maintenance Manual

Instruction and Maintenance Manual Instruction and Maintenance Manual GRYF OXY Z 02/100/2 E Contact GRYF HB, spol. s r.o. Cechova 314 Havlickuv Brod 580 01 tel.: +420 569 426 627 fax: +420 569 426 627 Czech Republic www.gryf.eu Technical

More information

Supplementary Certificate of Approval. No S433

Supplementary Certificate of Approval. No S433 12 Lyonpark Road, North Ryde NSW 2113 Australia Supplementary Certificate of Approval No S433 Issued under Regulation 60 of the National Measurement Regulations 1999 This is to certify that an approval

More information

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy.

Supersedes: The copy of this document located on Measurement Canada s website is considered to be the controlled copy. Bulletin Category: GAS Bulletin: G-23 Page: 1 of 7 The copy of this document located on Measurement Canada s website is considered to be the controlled copy. Recognition of data from specialty gas suppliers

More information

广东锐陆光电科技有限公司 GUANG DONG ELITE PHOTOELECTRIC TECHNOLOGY CO.,LTD. Product Specification

广东锐陆光电科技有限公司 GUANG DONG ELITE PHOTOELECTRIC TECHNOLOGY CO.,LTD. Product Specification Product Specification MODEL : 5050A Product Description : EMC5050 5W 36V Address:Guanhuang North road Hu anwei Gaobu Town Tel: 0769-89080660 Fax: 0769-89080658 Page 1 of 8 Feature Viewing angle:120 deg

More information

FL200 Monochromatic Architectural Spot and Floodlight

FL200 Monochromatic Architectural Spot and Floodlight DATE: TYPE: COMPANY: PROJECT: 360 375mm 14.7in 463mm 18.2in 269mm 10.7in 421mm 16.6in 77mm 3.0in *SM bracket mounting option shown. See page 2 for more mounting options. FEATURES: OPTIONS: Over 16,500

More information

POWERSTAR HQI -TM 600 and 1000W POWERBALL HCI -TM 250 and 400W

POWERSTAR HQI -TM 600 and 1000W POWERBALL HCI -TM 250 and 400W POWERSTAR HQI -TM 600 and 1000W POWERBALL HCI -TM 250 and 400W OSRAM POWERSTAR HQI-TM 1000W/960 D On stock on request HQI-TM 1000W/960 D OSRAM HQI-TM 1000W/ 960 D OSRAM HQI-TM 1000W/ 960 D HR Luminous

More information

Total Ionization Dose (TID) Test Results of the RH117H Positive Adjustable Low Dose Rate (LDR) LDR = 10 mrads(si)/s

Total Ionization Dose (TID) Test Results of the RH117H Positive Adjustable Low Dose Rate (LDR) LDR = 10 mrads(si)/s Total Ionization Dose (TID) Test Results of the RH117H Positive Adjustable Regulator @ Low Dose Rate (LDR) LDR = 10 mrads(si)/s 18 December 2014 Duc Nguyen, Sana Rezgui Acknowledgements The authors would

More information

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007

Requirements and Methods for Calibration of Equipment in Clinical Laboratories. NK Chan (HKRCBTS) 24 August 2007 Requirements and Methods for Calibration of Equipment in Clinical Laboratories NK Chan (HKRCBTS) 24 August 2007 1 Contents Basic Requirements of Equipment Calibration Calibration of Electronic Balance

More information

Total Ionization Dose (TID) Test Results of the RH1021BMH-10 Precision 10V Low Dose Rate (LDR) LDR = 10 mrads(si)/s

Total Ionization Dose (TID) Test Results of the RH1021BMH-10 Precision 10V Low Dose Rate (LDR) LDR = 10 mrads(si)/s Total Ionization Dose (TID) Test Results of the RH1021BMH-10 Precision 10V Reference @ Low Dose Rate (LDR) LDR = 10 mrads(si)/s 22 September 2014 Duc Nguyen, Sana Rezgui Acknowledgements The authors would

More information

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010

Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600. November 2010 Predicted Dispense Volume vs. Gravimetric Measurement for the MICROLAB 600 November 2010 Table of Contents ``Abstract...3 ``Introduction...4 ``Methods & Results...6 ``Data Analysis...9 ``Conclusion...12

More information

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience -

Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience - Certification of AMS acc. EN 15267, Part 3 - Overview and First Experience - Dr. Wolfgang Jockel, Martin Schneider, TÜV Rheinland Group, D-51105 Cologne / Germany 1. Introduction A new basis for the certification

More information

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE PRODUCT CONFORMITY CERTIFICATE This is to certify that the Endura AZ20 / AZ30 measuring system Manufactured by: ABB Ltd Oldends Lane Stonehouse Gloucestershire GL10 3TA has been assessed by Sira Certification

More information

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST

THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST THE PRESSURE SIGNAL CALIBRATION TECHNOLOGY OF THE COMPREHENSIVE TEST SYSTEM Yixiong Xu Mechatronic Engineering, Shanghai University of Engineering Science, Shanghai, China ABSTRACT The pressure signal

More information

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration

CTAG:e43bda4f8e48714fbb aefb192 Certificate of Calibration CTAG:ebdaf8e87fbb5996aefb9 Certificate of Calibration Data Type: FOUND-LEFT Certificate No: 6858 Instrument Description Manufacturer Model Serial Number Inventory Number CABLE ANALYZER FLUKE NETWORKS DTX-8

More information

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.

The HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc. The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is

More information

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.:

L (up to 25 m) Electronic part. working temp.: Ñ IP 66 / IP67. Mounting bracket ÐÑ. Sensor type. working temp.: Smart level probe type APC-2000ALW/L Programmable zero shift, range and damping ratio 4...20 ma output signal + HART protocol Accuracy 0,16% Local display Intrinsic safety certificate (ATEX, IECEx) II

More information

UniBloc technology and over 80 years of experience in precision weighing. Registered

UniBloc technology and over 80 years of experience in precision weighing.   Registered UniBloc technology and over 80 years of experience in precision weighing http://www.shimadzu.com/balance/ Registered AUW-D AUW AUX AUYSeries Shimadzu s UniBloc technology and over 80 years of experience

More information

Application Note AN-107

Application Note AN-107 SPEC Sensor TM Characterization & Calibration Considerations Scope This document is provided to describe the considerations needed to characterize, calibrate, verify and validate the measurement performance

More information

Gas mixtures. Individual solutions specifically for your application

Gas mixtures. Individual solutions specifically for your application Gas mixtures Individual solutions specifically for your application For many applications besides pure gases also defined gas mixtures are required. For many routine applications, from operating gases

More information

Total Ionization Dose (TID) Test Results of the RH1028MW Ultralow Noise Precision High Speed Operational Low Dose Rate (LDR)

Total Ionization Dose (TID) Test Results of the RH1028MW Ultralow Noise Precision High Speed Operational Low Dose Rate (LDR) Total Ionization Dose (TID) Test Results of the RH1028MW Ultralow Noise Precision High Speed Operational Amplifiers @ Low Dose Rate (LDR) LDR = 10 mrads(si)/s 20 February 2015 Duc Nguyen, Sana Rezgui Acknowledgements

More information

3M Steri-Vac Sterilizer/Aerator GSX Series. For Life Science Applications. Product. Profile

3M Steri-Vac Sterilizer/Aerator GSX Series. For Life Science Applications. Product. Profile M Steri-Vac Sterilizer/Aerator GSX Series Product Profile Product Profile M Steri-Vac Sterilizer/Aerator GSX Series ethylene oxide (EO) sterilizer/aerators are designed to be used with M Steri-Gas EO Gas

More information

Mass Flowmeters. Mass Flowmeters for Gases

Mass Flowmeters. Mass Flowmeters for Gases Mass Flowmeters Mass Flowmeters for Gases Fast, Accurate, Low Pressure Drop for critical measurement applications! Flow (Std l/min) Response to a step change in flowrate 300 200 100 4 Milliseconds 63%

More information

Online data sheet FLOWSIC30 GAS FLOW METERS

Online data sheet FLOWSIC30 GAS FLOW METERS Online data sheet A B C D E F H I J K L M N O P Q R S T Ordering information LTRASONIC GAS FLOW METER FOR CTION Type Part no. On request The exact device specifications and performance data of the product

More information

THE USE OF Z FACTORS IN GRAVIMETRIC VOLUME MEASUREMENTS

THE USE OF Z FACTORS IN GRAVIMETRIC VOLUME MEASUREMENTS THE USE OF Z FACTORS IN GRAVIMETRIC VOLUME MEASUREMENTS Author: T. Mautjana NMISA Private Bag X 34 Lynwood Ridge; 0040 Email: tmautjana@nmisa.org Phone: 012 841 4798; Fax: 012 841 2131 Abstract Using gravimetric

More information

DeFelsko PosiTector CMM IS Probe

DeFelsko PosiTector CMM IS Probe Management Procedure 2566 Revision: A Date Issued: January 23, 2018 Date Revised: Calibration Procedure DeFelsko PosiTector CMM IS Probe Table of Contents 1 Introduction and UUC Performance Requirements...

More information

5mm Infrared LED HIR7373B/L289

5mm Infrared LED HIR7373B/L289 5mm Infrared LED Features High reliability High radiant intensity Peak wavelength λp=850nm 2.54mm Lead spacing Low forward voltage Pb Free This product itself will remain within RoHS compliant version.

More information

Product Specification Spring Finger

Product Specification Spring Finger Product Specification 108-115008-3 Spring Finger Restricted to Sony Ericsson Mobile Communications 1. SCOPE 1.1. Content This specification covers the requirements for product performance test methods

More information

HumiSys HF High Flow RH Generator

HumiSys HF High Flow RH Generator HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously

More information

Test Summary Report Giraffe 2.0 Hybrid Wind-Solar Power Station - for wind: according to IEC Annex M - for solar: measurement report

Test Summary Report Giraffe 2.0 Hybrid Wind-Solar Power Station - for wind: according to IEC Annex M - for solar: measurement report Contact person Tanja Tränkle 2016-06-29 4P05805-R01 rev. 1 1 (7) Safety +46 10 516 57 19 Tanja.Trankle@sp.se Innoventum AB Morgan Widung / Marcus Ulmefors Turning Torso office 275 Lilla Varvsgatan 14 211

More information

Wafer type. the product

Wafer type. the product . VFM5 Vortex Flow Meter Flanged type Wafer type Insertion type VFM5 is a powerful flow meter utilizing Karman vortex theory, which can meet the requirement of measuring the flow rate of various fluids

More information

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0

Rigel 601 CHECKBOX. Instruction Manual. 348A551 Issue 2.0. April Seaward Electronic Ltd. Issue 2.0 Rigel 601 CHECKBOX Instruction Manual 348A551 Issue 2.0 April 2006 2006 Seaward Electronic Ltd. Issue 2.0 Limited Warranty & Limitation of Liability Rigel Medical guarantees this product for a period of

More information

PC10 Piezoresistive Silicon Pressure Sensor

PC10 Piezoresistive Silicon Pressure Sensor PC10 Piezoresistive Silicon Pressure Sensor Features With constant current and constant voltage excitation options Imported highly reliable pressure die Wide temperature compensation Normalized output

More information

5mm Infrared LED,T-1 HIR323C

5mm Infrared LED,T-1 HIR323C ,T-1 Features High reliability High radiant intensity Peak wavelength λp=850nm 2.54mm Lead spacing Low forward voltage Pb Free This product itself will remain within RoHS compliant version. Compliance

More information

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

FTC130 Transmitter. Operating Manual

FTC130 Transmitter. Operating Manual Seite 1 von 11 FTC130 Transmitter Fast Thermal Conductivity Analyzer Operating Manual 1.09KD180724CWI1V05 Messkonzept GmbH Seite 2 von 11 1. Intended Use... 3 2. Description... 4 3. Measuring gases and

More information

KENYA ACCREDITATION SERVICE

KENYA ACCREDITATION SERVICE KENAS-GUD-016 01 16/03/2013 16 / 04/2013 GUD Page 1 of 18 Approval and Authorisation Completion of the following signature blocks signifies the review and approval of this Document. Name Job Title / Role

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc. has assessed the Laboratory of: 12100 West 6 th Avenue, Lakewood, CO 80225 (Hereinafter

More information

Specification for Approval

Specification for Approval Specification for Approval Part No : LWM1056N comments LUXPIA Co., Ltd. Designed by Checked by Approved by Approved by Approved by Approved by / / / / / / Date :... Date :... LUXPIA CO.,LTD. 948-1, Dunsan-Li

More information

MPG-plus. Application example. Pneumatic 2-Finger Parallel Gripper Gripper for small components. Gripping force 38 N 175 N. Sizes

MPG-plus. Application example. Pneumatic 2-Finger Parallel Gripper Gripper for small components. Gripping force 38 N 175 N. Sizes MPG-plus Sizes 25 40 Weight 0.06 kg 0.24 kg Gripping force 38 N 175 N Stroke per finger 3 mm 6 mm Workpiece weight 0.19 kg 0.7 kg Application example Pneumatically driven, dual-axis pick-and-place machine

More information

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters

Model NDA Differential pressure transmitter. Deltapi N Series A complete range of pneumatic pressure transmitters Data Sheet DS/NDA-EN Rev. H Model NDA Differential pressure transmitter Deltapi N Series A complete range of pneumatic pressure transmitters Introduction The blind type differential pressure transmitter

More information

Particulate Emission Monitor Correlation. Camden Power Station Stack No RSL152

Particulate Emission Monitor Correlation. Camden Power Station Stack No RSL152 Particulate Emission Monitor Correlation Camden Power Station Stack No. 3 2011 P.O. Box 2459 Noordheuwel ext 4 Krugersdorp 1756 Vat No. 4670254459 STACKLABS ENVIRONMENTAL SERVICES 10 Chisel Street Boltonia

More information

Differential Pressure Transmiter

Differential Pressure Transmiter Differential Pressure Transmiter Description The is an economical alternative to established differential pressure transmitters. It combines state of the art electronics and a high performance sensor;

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

EC214 EC215 - EC215R Bench Conductivity Meters

EC214 EC215 - EC215R Bench Conductivity Meters Instruction Manual EC214 EC215 - EC215R Bench Conductivity Meters http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments

More information

Integral type Differential pressure flowmeter VNT Series

Integral type Differential pressure flowmeter VNT Series Integral type Differential pressure flowmeter VNT Series OUTLINE VH series Wafer-Cone differential pressure flowmeter and high precision differential pressure transmitter are integrated into one flowmeter.

More information

Pneumatic high-pressure controller Model CPC7000

Pneumatic high-pressure controller Model CPC7000 Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter

More information

High Curent Inductor / MPSZ Type

High Curent Inductor / MPSZ Type .Features: 1. Shielded construction. 2. Frequency range up to 1.0 MHz. 3. Lowest DCR / μh, in this package size..applications: 1. Handles high transient current spikes without saturation. 2. Ultra low

More information