Materials : Brass body dezincification-resistant up to DN1 1/4

Size: px
Start display at page:

Download "Materials : Brass body dezincification-resistant up to DN1 1/4"

Transcription

1 Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2" Male, Male BSP + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass body dezincification-resistant up to DN1 1/4 Controlable With male union Materials : Brass body dezincification-resistant up to DN1 1/4 *the installation defects and wear defects are not covered by the guarantee Page 1 sur 13

2 SPECIFICATIONS : Respect the flow direction indicated by an arrow on the body Horizontal position Male / Male BSP Controlable Low head loss With male union With ball valves 1/4 BSP 10 years manufacture warranty (the installation defects and wear defects are not covered by the guarantee) USE : Water distribution Min Temperature Ts : + 5 C Max Temperature Ts :+ 65 C Max Pressure PN : 10 bars HEAD LOSS GRAPH : FLOW Page 2 sur 13

3 HEAD LOSS GRAPH ( SUITE ) : FLOW FLOW Page 3 sur 13

4 OPERATING PRINCIPLE : The controllable reduced pressure zone backflow preventer is comprised of: a body with an inspection cover, an upstream check valve (1), a downstream check valve (2), a discharge device (3).The two check valves divide three different zones, each of which at a different pressure: an upstream or inlet zone (A); an intermediate zone, also known as the reduced pressure zone (B); a downstream or outlet zone (C). Each of these has a test port for measuring pressure. A discharge device (3), is located in the lower part of the intermediate zone. The obturator of the discharge device is connected via the valve stem (4) to the diaphragm (5).This mobile unit is pushed upwards by the spring (6). The diaphragm (5) marks the limit of the top chamber (D), which is connected to the upstream zone by the channel (7). Normal flow conditions : Under conditions of normal flow, both check valves are open, while the pressure in the intermediate chamber (B) is always lower that the inlet pressure by at least 140 mbar due to the pressure loss caused by the check valve (1).In the top chamber (D), however, the pressure is the same as in the inlet zone.in this situation, the mobile unit consisting of the diaphragm (5), the valve stem (4) and the valve obturator (3) is pushed down by the push created by the difference in pressure acting on the diaphragm which is greater than that of the spring(6) acting in the opposite direction.the discharge valve is therefore held in the closed position. No flow conditions : The check valves (1) and (2) are now closed. Since the pressure in the upstream zone and therefore also in the top chamber (D), is still at least 140 mbar higher than the pressure in the intermediate chamber (B), the discharge valve remains closed. Page 4 sur 13

5 OPERATING PRINCIPLE ( SUITE ) : Upstream pressure loss : Both check valves close as the pressure upstream drops. The discharge valve (3) opens when the difference in pressure P,between the upstream and the intermediate zones falls, drops below 140 mbar.under these conditions the action exerted by the pressure difference P on the diaphragm (5), becomes weaker than that exerted by the spring (6), and the discharge valve (3) opens as aresult. Discharge then occurs until the body of the backflowpreventer is empty. When the situation returns to normal (pressure upstream greater than pressure downstream), the discharge valve closes and the backflow preventer is again ready to operate. Downstream back pressure : If the pressure in the downstream zone increases until it is greater than the upstream pressure, the check valve (2) closes and therefore prevents water already delivered from returning back into the mains system. If the seal of the check valve (2), is slightly defective or in general terms there is any other type of fault in the backflow preventer, the device always interrupts (disconnects) the connection between the mains system and the receiving system. The backflow preventer has been designed with all construction details required for a properly functioning positive action device; the best possible safety conditions are therefore ensured under all conditions. RANGE : Male - Male threaded BSP ends with male union from DN 1/2 to DN 2 Ref.950 Page 5 sur 13

6 MATERIALS : Item Designation Materials DN 1/2 1 1/4 Materials DN 1 1/2 2 1 Body Brass dezincification-resistant CW602N according to EN Bronze 2 Bonnet Brass dezincification-resistant CW602N according to EN Bronze 3 Stem Stainless steel Stainless steel 4 Check valve Brass Brass 5 Spring Stainless steel Stainless steel 6 Diaphragm EPDM EPDM 7 Gasket NBR NBR 8 Evacuation Support Plastic Brass Page 6 sur 13

7 SIZE ( in mm ) : DN 1/2" DN 3/4" 1 DN 1"1/4 DN 1"1/2 2 DN 1/2"-2 (without fittings) Ref. DN 1/2" 3/4" 1 1 1/4 1 1/2 2 DN1 3/4" 1 1/4 1 1/4 1 1/2 2 1/2 2 1/2 L L H H H Ø D Weight ( Kg ) Page 7 sur 13

8 STANDARDS : Fabrication according to ISO 9001 : 2008 DIRECTIVE 97/23/CE : Products excluded from directive ( Article ) French water agreement A.C.S. N 09 ACC LY 090 Approval Belgian certificate BELGAQUA N 11/026/BA Approval Holland certificate KIWA N K 6382/05 Approval Swiss certificate SVGW N Approval Swedish certificate SITAC N SC Approval Australian certificate WATERMARK N WMKA01764 for DN1 1/4 to 2 Approval English certificate WRAS N Designing according to NF P and EN Safety device according to NF045 doc 3 and EN Acoustic Group I up to DN 1 1/4 NF No pollution certificate N /1 completed by : o NF EN o NF EN 1717 Threaded male BSP cylindrical ends according to ISO for DN 1/2 Threaded male BSP conical ends according to ISO 7-1 R from DN 3/4 to DN 2 ADVICE : Our opinion and our advice are not guaranteed and SFERACO shall not be liable for the consequences of damages. The customer must check the right choice of the products with the real service conditions. Page 8 sur 13

9 BACKFLOW : Potable water fed from the mains supply may suffer from hazardous pollution caused mainly by contaminated fluids from plumbing systems flowing back directly into the mains supply. This phenomenon, termed backflow occurs when: a) the pressure in the mains system is less that in the plumbing circuit receiving the supply (back syphonage). This situation may occur when there is a pipe breaking in the mains system or when demand on the mains supply from consumers is very heavy. b) the pressure in the plumbing circuit receiving the supply rises (back pressure) due, for example, to water being pumped from a well. Risk assessment. Given the potential dangers of the phenomenon and the requirements of current regulations, the risk of pollution from backflow must be assessed on the basis of the type of system and the characteristic of the fluid that flows in it. An appropriate backflow prevention device must be selected on the basis of that assessment performed by the system designer and the mains supplier. The device must be located along the supply line at those points at risk of backflow which would be hazardous to human health. The protection can be provided by inserting a backflow preventer at critical points in the circuit at the inlet from the mains supply or in the internal plumbing system. This will prevent polluted water from flowing back in all systems for which direct connection to the mains or an internal supply is considered hazardous. Page 9 sur 13

10 BACKFLOW PREVENTER USE, BA TYPE ( According to EN 1717 and EN ) : Page 10 sur 13

11 INSTALLATION : Backflow preventers must be installed by qualified personnel in accordance with current norms and regulations. They must be installed downstream from a shut-off valve and from a strainer with a discharge that can be inspected and another shut-off valve must be fitted downstream from it. The unit must be installed in an accessible position, appropriately located to avoid possible immersion due to accidental flooding (see diagram). The device must be fitted horizontally. The discharge tundish must comply with standard EN 1717 and be connected to the sewage piping. Before installing the backflow preventer and the strainer, the pipework must be flushed with a large flow rate. When used to protect the mains supply, backflow preventers must be installed downstream from the water meter, whereas when used to protect the potable water supply system for internal usage, they are installed at the limit of the zone where pollution might occur, e.g. central heating systems, garden irrigation systems, etc. Annual maintenance must be done once per year by a professional If these operations are not done, the product can t be guaranteed. Page 11 sur 13

12 Page 12 sur 13

13 INSTALLATION INSTRUCTIONS GENERAL GUIDELINES : Ensure that the check valves to be used are appropriate for the conditions of the installation (type of fluid,pressure and temperature). Be sure to have enough valves to be able to isolate the sections of piping as well as the appropriate equipment for maintenance and repair. Ensure that the valves to be installed are of correct strenght to be able to support the capacity of their usage. INSTALLATION INSTRUCTIONS : Before installing the check valves, clean and remove any objects from the pipes (in particular bits of sealing and metal) which could obstruct and block the valves. Ensure that both connecting pipes either side of the check valve (upstream and downstream) are aligned (if they re not,the valves may not work correctly). Make sure that the two sections of the pipe (upstream and downstream) match, the check valve unit will not absorb any gaps.any distortions in the pipes may affect the thightness of the connection,the working of the check valve and can even cause a rupture.to be sure,place the kit in position to ensure the assembling will work. Before starting the fitting, ensure that the threads and tapping are clean. If sections of piping do not have their final support in place,they should be temporarily fixed.this is to avoid unnecessary strain on the check valve. The theoretical lenghts given by ISO/R7 for the tapping are typically longer than required,the lenght of the thread should be limited, and check that the end of the tube does not press right up to the head of the thread. For the sealing assembly check valve piping, it is essential to use products that are compatible with the requirements of the French water agreement ACS : plumbers hemp proscribed. If mounting on an air conditioning with PER tubing and hoses,it is necessary to support the tubes and hoses with the fixing to avoid strain on the check valve. When screwing the check valve, ensure that you only rotate on screwed side by the 6 ended side.use an open ended spanner or an adjustable spanner and not a monkey wrench. Never use a vice to tighten the fixings of the check valve. Do not over tighten the check valve.do not block with any extensions as it may cause a rupture or weakening of the casing. In general,for all check valves used in buildings and heating,do not tighten above a torque of 30 Nm. If there is a direction changing or if there s another material, it s better to take away the check valve so that it is outside the turbulence area ( between 3 and 5 times the ND before and after ). After a pump please refer to norm NF CR to install the check valve. Page 13 sur 13

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2

DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2 Size : Ends: Min Temperature : Max Temperature : DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2 Materials : Bronze body

More information

Materials : Brass body dezincification-resistant

Materials : Brass body dezincification-resistant Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 3/4" Female female BSP + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass body dezincification-resistant Non Controlable With female

More information

DN 1/4" to 3" Female BSP - 10 C C Max Pressure : 25 Bars ( up to DN 1 ) Specifications : Anti blow-out stem With PTFE packing Full bore

DN 1/4 to 3 Female BSP - 10 C C Max Pressure : 25 Bars ( up to DN 1 ) Specifications : Anti blow-out stem With PTFE packing Full bore Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 3" Female BSP - 10 C + 120 C Max Pressure : 25 Bars ( up to DN 1 ) Specifications : Anti blow-out stem With PTFE packing Full bore Materials

More information

Materials : Stainless steel ASTM A351 CF8M

Materials : Stainless steel ASTM A351 CF8M Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 3/4" Male, hose coupling - 10 C + 150 C Max Pressure : 16 Bars Specifications : Anti blow-out stem Locking device With hose coupling Materials

More information

DN 1/2" to 2" Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore

DN 1/2 to 2 Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2" Female / Female BSP - 5 C + 60 C Max Pressure : 5 Bars Specifications : Anti blow-out stem Double o ring NBR on stem Full bore Materials

More information

DN 3/8" to 4" Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female

DN 3/8 to 4 Female BSP - 10 C C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female Size : Ends : Min Temperature : Max Temperature : DN 3/8" to 4" Female BSP - 10 C + 120 C Max Pressure : 16 Bars up to DN 2 Specifications : Removable stainless steel filter Female / Female Materials :

More information

DN 1/2" to 2 Female - Female BSP - 20 C C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore

DN 1/2 to 2 Female - Female BSP - 20 C C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2 Female - Female BSP - 20 C + 180 C Max Pressure : 16 Bars Specifications : Rotating non rising stem Inside screw stem Full bore Materials

More information

DN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve

DN 1/2 to 2 Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2" Female BSP + 0 C + 120 C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve Materials

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Ends : Min Temperature : Max Temperature : DN 40 to DN 300 Flanges R.F. PN10/16-10 C + 80 C Max Pressure : 16 Bars up to DN200 Specifications : Removable stainless steel filter Bolted bonnet with

More information

Materials : Forged carbon steel A105N

Materials : Forged carbon steel A105N Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 1/4" to 2 Female - Female BSP or NPT, Socket Welding - 29 C + 425 C Max Pressure : 136 Bars (Class 800) Specifications : With draining

More information

Materials : Forged carbon steel A350 LF2

Materials : Forged carbon steel A350 LF2 Size : Ends : Min Temperature : Max Temperature : DN 15 to 50 (NPS 1/2" to 2") Female - Female NPT, Socket Welding - 46 C + 425 C Max Pressure : 250 Bars (Class 1500) Specifications : Rising rotating stem

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Ends : Min Temperature : Max Temperature : DN 15 to DN 400 Flanges GN10/16-10 C + 120 C Max Pressure : 16 Bars up to DN 200 ( 10 bars over ) Specifications : Removable stainless steel filter Bolted

More information

Materials : Forged carbon steel A105N

Materials : Forged carbon steel A105N Size : Ends : Min Temperature : Max Temperature : DN 15 to 50 (NPS 1/2" to 2") Socket Welding -29 C + 425 C Max Pressure : 250 Bars (Class 1500) Specifications : Rising stem (OS&Y) Welded bonnet Full bore

More information

Forged stainless steel ASTM A182 F316

Forged stainless steel ASTM A182 F316 MADE OF STAINLESS... Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 8 to 25 (NPS 1/4" to 1") Female - Female NPT - 29 C + 538 C Max Pressure : 138 Bars (Class 800) Specifications

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 :

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron EN GJL 250 body. Reinforced lug for DN200 : Reinforced lug for DN200 : Size : Ends : Min Temperature : Max Temperature : DN 50 to 200 mm Between flanges ISO PN10/16 ( PN10 for DN200 ) - 10 C + 110 C Max Pressure : 10 Bars Specifications : Long neck

More information

Materials : Forged carbon steel A105N

Materials : Forged carbon steel A105N Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 15 to 50 (NPS 1/2" to 2") Flanges RF CLASS 150 (PN20) - 29 C + 425 C Max Pressure : 20 Bars Specifications : Rising non rotating stem

More information

Materials : Stainless steel ASTM A351 CF8M

Materials : Stainless steel ASTM A351 CF8M Certificat 3.1 Size: Ends : Min Temperature : Max Temperature : DN 15 to DN 200 PN16 Flanges R.F. - 20 C + 200 C Max Pressure : 16 Bars Specifiations : Removable stainless steel filter Bolted bonnet with

More information

Ref GAS WAFER BUTTERFLY VALVE. Model/Ref:

Ref GAS WAFER BUTTERFLY VALVE.  Model/Ref: Model/Ref: 1141 www.lauridsenindustri.com Size : Ends : Min Temperature : Max Temperature : DN 32/40 to 200 mm Between ISO PN10/16 and ANSI150 flanges - 20 C + 60 C Max Pressure : 5 Bars Specifications

More information

Materials : Carbon steel ASTM A216 WCB

Materials : Carbon steel ASTM A216 WCB Certificate 3.1 Size : Ends : Min Temperature : Max Temperature : DN 50 to DN 400 ( NPS 2" to 16" ) Flanges R.F. Class 150 (PN20) - 29 C + 425 C Max Pressure : 20 Bars Specifications : Removable stainless

More information

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function

CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function Reduced pressure zone backflow preventer series LEFFI 01022/18 N REITE ISO 9001 FM 216 ISO 9001 No. 000 Function The backflow preventer can be used in all plumbing systems where there is danger of the

More information

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body

Size : Connection Ends : Min Temperature : Max Temperature : Materials : Cast iron body Size : Connection Ends : Min Temperature : Max Temperature : DN 50 to 200 Flanged ISO PN 10/16 ( ISO PN16 for DN200 ) 0 C + 50 C Max Pressure : 16 Bars Specifications : Tangential type Dry dial Magnetic

More information

High Performance BSP Dial Up Pattern Pressure Reducing Valve

High Performance BSP Dial Up Pattern Pressure Reducing Valve See our full range online at: www.vip-ltd.co.uk High Performance BSP Dial Up Pattern Pressure Reducing Valve VIP Product Code 31/0103 FUNCTION Pressure reducing valves are devices which, when installed

More information

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E

Serie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions 488.03 www.reece.com.au Pressure reducing s Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet

More information

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection

Serie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection Flanged back flow preventer with controllable reduced pressure zone made in Application fields WATER FIRE FIGHTING DRINKING WATER 64 www.brandoni.it The ECO 3F flanged backflow preventers, which have a

More information

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series

Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Main features Designed for automatic filling of sealed heating systems and for protection of the water mains from risk of contamination.

More information

Installation, commissioning and servicing instructions

Installation, commissioning and servicing instructions 48323 www.caleffi.com Pre-adjustable pressure reducing valve with self-contained cartridge Copyright 2015 Caleffi 5350..H AUS series Installation, commissioning and servicing instructions Function Pressure

More information

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections

Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections Features General application The RP03 provides protection from both backsiphonage and backpressure

More information

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03 Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure

More information

Materials : Electro galvanized steel flanges

Materials : Electro galvanized steel flanges Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications : Absorb vibrations and noises

More information

553 Series.

553 Series. 38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual

More information

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE

STAINLESS STEEL LOW PRESSURE REDUCING VALVE LPRV ELITE MAIN CHARACTERISTICS The stainless steel LPRV elite low pressure reducer is intended for the pressure reduction of the fluids such as water, air, clear liquids not in charge of and the compatible gases

More information

Materials : Galvanized steel flanges

Materials : Galvanized steel flanges Size : Ends : Min Temperature : Max Temperature : DN 32 to 200 Flanges PN10/16-10 C + 80 C Max Pressure : 16 Bars Specifications : Absorb vibrations and noises Linear and angular compansion Single NBR

More information

C 10 Pressure Reducing Valve

C 10 Pressure Reducing Valve C 10 Pressure Reducing Valve C 10 Direct Acting Pressure Reducing Valve The C10 balanced pressure reducing valve range is designed for use on water/air (gas) applications and for installations which have

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges

Size : Ends : Min Temperature : Max Temperature : Materials : Galvanized steel flanges Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges ISO PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications : Absorb vibrations and noises

More information

AVP-F. p setting range (bar) Code No. 003H6200

AVP-F. p setting range (bar) Code No. 003H6200 Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator

More information

differential pressure regulating valve - threaded

differential pressure regulating valve - threaded 140-142 differential pressure regulating valve - threaded Introduction Differential pressure regulating valves (DPRV) maintain the differential pressure across a circuit or sub-branch at a set differential

More information

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in

More information

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2

Mounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2 Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting

More information

Materials : Dichromate zinc plated steel flanges or AISI 316

Materials : Dichromate zinc plated steel flanges or AISI 316 Size : Ends : Min Temperature : Max Temperature : DN 25 to 300 Flanges PN10/16-35 C + 90 C Max Pressure : 16 Bars (10 bars at 90 C) Specifications : Absorb vibrations and noise Linear and angular compansion

More information

ELKHART BRASS MANUFACTURING COMPANY

ELKHART BRASS MANUFACTURING COMPANY ELKHART BRASS MANUFACTURING COMPANY INSTALLATION and OPERATING INSTRUCTIONS for MODEL UP PRESSURE RESTRICTING HOSE VALVES I. Models and Sizes Covered: UP-20, 1-1/2" size UP-25, 1-1/2" size UP-20, 2-1/2"

More information

STAINLESS STEEL OVERFLOW VALVE TYPE 417

STAINLESS STEEL OVERFLOW VALVE TYPE 417 MAIN CHARACTERISTICS The 417 valve is intended for the discharge of fluids overflow when an upstream limitation of pressure is looked for, for example downstream to a pump. This valve also works in presence

More information

ACCREDITED. Technical specifications series

ACCREDITED. Technical specifications series nti-pollution check valves 0-0-0-0-0 series REITE ISO 0 FM LEFFI 000/ G replaces dp 000/0G Function The anti-pollution check valve is a protective plumbing device capable of preventing the backflow of

More information

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Description AVP(-F) is a self-acting differential pressure controller primarily for use in district heating systems.

More information

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS THE COMPANY ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and

More information

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS

TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution

More information

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB

CALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM CLEFFI /7 GB replaces / GB Function Pressure reducing valves are devices which, when installed on private

More information

CAST IRON SAFETY VALVE TYPE 6301

CAST IRON SAFETY VALVE TYPE 6301 CHARACTERISTICS The 6301 safety valve is dedicated to protect the equipment from potential overpressure. This is an automatic device that closes when the pressure conditions are back to normal. It is a

More information

2-port seat valves PN25 with externally threaded connections

2-port seat valves PN25 with externally threaded connections 4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with

More information

Materials : Dichromate zinc plated steel flanges

Materials : Dichromate zinc plated steel flanges Size : Ends : Min Temperature : Max Temperature : DN 25 to 300 Flanges PN10/16-35 C + 130 C Max Pressure : 16 Bars up to DN150, 10 bars over Specifications : Absorb vibrations and noise Linear and angular

More information

WE SAY: CLEANLY SEPARATED SYSTEMS = ELKO-MAT EDER!

WE SAY: CLEANLY SEPARATED SYSTEMS = ELKO-MAT EDER! elko-mat BACKFLOW PREVENTER WE SAY: CLEANLY SEPARATED SYSTEMS = ELKO-MAT EDER! Technical datasheet Ver.02/2017-en 1. Safety guidelines Follow the installation instructions Use the appliance according to

More information

Engineering Data Sheet

Engineering Data Sheet Page 1 of 6 CE MARKING AND THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC Valves must be installed into a well designed system and it is recommended that the system be inspected in accordance with the appropriate

More information

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions Ballorex Delta Description The Ballorex Delta is a differential pressure control valve used in hydronic heating or cooling systems. By ensuring a constant differential pressure across motorized or static

More information

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION

TECHNICAL DATA ANTI-FLOOD DEVICE MODEL B-1 1. DESCRIPTION Page 1 of 6 1. DESCRIPTION The Model B-1 Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET condition,

More information

Pre-adjustable pressure reducing valves with self-contained cartridge

Pre-adjustable pressure reducing valves with self-contained cartridge Pre-adjustable pressure reducing valves with self-contained cartridge 535..H series ACCREDITED ISO 91 FM 15 15/17 GB replaces 15/1GB Function Pressure reducing valves are devices which, when installed

More information

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves STAD-D Balancing valves Balancing valve for domestic water systems, DN 15-50 Balancing valves IMI TA / Balancing valves / STAD-D STAD-D The STAD-D balancing valve delivers accurate hydronic performance

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

GUMMIKOMPENSATOR GKF8000 / GKF8130

GUMMIKOMPENSATOR GKF8000 / GKF8130 GUMMIKOMPENSATOR GKF8000 / GKF8 Size : Ends : Min Temperature : Max Temperature : DN 32 to 600 Flanges PN10/16-10 C + 100 C for EPDM and + 80 C for NBR Max Pressure : 16 Bars up to DN 300 Specifications

More information

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914

Installation, Operating and Maintenance Instructions. V914 Cast Iron Flanged Swing Check Valve V914 Installation, Operating and Maintenance Instructions V914 Cast Iron Flanged Swing Check Valve V914 THE PRESSURE EQUIPMENT DIRECTIVE 97/23/EC and CE MARKING The Pressure Equipment Regulations 1999 (SI 1999/2001)

More information

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN

Differential Pressure Regulator Type Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Differential Pressure Regulator Type 45-6 Type 45-6 (0.1 to 1 bar, DN 15) Mounting and Operating Instructions EB 3226 EN Edition March 2008 Contents Contents Page 1 Design and principle of operation...................

More information

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level.

Description. Functions. Technical data. Applications. Tests. On-Off 2 levels float control valve, closing at high level and opening at low level. DN 0 to 1000 - Serie K3 0 On-Off levels float control valve, closing at high level and opening at low level. Functions Prevents overflowing and closes at a constant and adjustable high level. Remains closed

More information

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

BTV. Internally threaded 2-way control valve. Flow characteristics. Function Internally threaded 2-way control valve The valves are designed for control of hot, cold or glycol-mixed water in heating and ventilation systems. They are pressure balanced (from DN20-50, not DN15) and

More information

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve Self-operated Pressure Regulators Type 41-23 Universal Pressure Reducing Valve JIS version Application Pressure regulators for set points from 5 to 2800 kpa/0.05 to 28 bar Valve sizes ½B/15A to 4B/100A

More information

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03

VALVCHEQ BACKFLOW PREVENTERS FIGURE RP03 Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

GUKO FDA. einfach. gut. beraten.

GUKO FDA. einfach. gut. beraten. GUKO FDA Size : Ends : Min Temperature : Max Temperature : DN 25 to 300 Flanges PN10/16-25 C + 90 C Max Pressure : 16 Bars Specifications : Absorb vibrations and noise Linear and angular compansion Inner

More information

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28

Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) Type Type 42-28 Series 42 Self-operated Regulators Differential Pressure Regulators with Type 2424/Type 2428 Actuator (closing) and balanced Type 2422 Valve Type 42-24 Type 42-28 Application Differential pressure regulators

More information

KTM 50 (DN ) Installation, maintenance and operating instructions

KTM 50 (DN ) Installation, maintenance and operating instructions 52 762-306 09.2014 KTM 50 (DN 100-200) Installation, maintenance and operating instructions General High-performing and compact, these pressure-independent control valves for variable flow heating and

More information

2-port and 3-port valves PN 16

2-port and 3-port valves PN 16 OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port

More information

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections

Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections VALVCHEQ Backflow Preventers Reduce pressure zone device suitable for high and medium hazard rated applications Flanged end connections Features General application The RP03 provides protection from both

More information

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE

MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE SIT Group SIT -3- SIGMA MULTIFUNCTIONAL CONTROL FOR GAS BURNING APPLIANCE 9.955. Subject to change without notice Application Domestic gas appliances: central heating boilers, combi boilers, instantaneous

More information

Anti-flood device Model B-1

Anti-flood device Model B-1 December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET

More information

Y-Pattern Strainer Valves Range

Y-Pattern Strainer Valves Range Y-Pattern Strainer Valves Range Conex Bänninger Y-Pattern Strainer Valves During installation and subsequent operation, debris and scale flowing through the system can cause considerable damage to pipeline

More information

Mainsboost Installation, Operation & Maintenance Instructions

Mainsboost Installation, Operation & Maintenance Instructions mainsboost Mainsboost Installation, Operation & Maintenance Instructions Please leave this instruction booklet with the home owner as it contains important guarantee, maintenance and safety information

More information

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer

book : t95575.fm Seite 1 Mittwoch, September 20, :10 AM. Avensys. Exposed Single Lever Mixer 955751.book : t95575.fm Seite 1 Mittwoch, September 20, 2000 10:10 AM Avensys Exposed Single Lever Mixer 33 389 33 396 Installation Instructions and Operating Guide Please leave this document with the

More information

CAST IRON VALVES FLOAT VALVE

CAST IRON VALVES FLOAT VALVE CAST IRON VALVES FLOAT VALVE NETAFIM CAST IRON VALVES FLOAT VALVE INLINE 25-400MM ANGLE 50-100MM SPECIFICATIONS Manufactured to ISO 9001 Available Valve sizes INLINE Flanged 50mm to 600mm & Threaded 19mm

More information

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting Data sheet Differential pressure controller (PN 16) AHP - return mounting, adjustable setting Description DN 15-40 DN 50 DN 65-100 AHP is a self-acting differential pressure controller primarily for use

More information

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref:

G type DUCTED EXHAUST SAFETY VALVE 2871 AND 288X SERIES. Model/Ref: Model/Ref: 28713 www.lauridsenindustri.com CHARACTERISTICS The G type safety valves are dedicated to protect the equipment from potential overpressure. They are automatic and close when the pressure conditions

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0

More information

Art PRESSURE REDUCER

Art PRESSURE REDUCER FUNCTION ICMA pressure reducers are devices that reduce and stabilize the incoming pressure from the water supply. Pressure reducers allow correct use on domestic systems, reducing malfunctions due to

More information

Expansion Vessels for Potable Installations

Expansion Vessels for Potable Installations 4. Expansion Vessels for Potable Installations Domestic installations lose millions of litres of potable water due to expansion water leaking from the vent and expansion pipe. Flamco s Airfix diaphragm

More information

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator. RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge

More information

Installation and operating instructions KEMPER Backflow Preventer BA Figure 361

Installation and operating instructions KEMPER Backflow Preventer BA Figure 361 Installation and operating instructions KEMPER Backflow Preventer BA Figure 361 1. Prerequisites for installation Install the backflow preventer in frost-free areas only! DIN EN 1717, DIN 1988 Comply with

More information

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Overview of types.   T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2) Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating

More information

Scald Protection Three-Way Thermostatic Mixing Valve

Scald Protection Three-Way Thermostatic Mixing Valve CALEFFI www.caleffi.com 383.04 Scald Protection Three-Way Thermostatic Mixing Valve Copyright 00 Caleffi 3 Series Installation, commissioning and servicing instructions Function Scald Protection Three-Way

More information

Pressure Relief Valve DHV 718

Pressure Relief Valve DHV 718 Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media

More information

Two-port valves, male threaded, PN25

Two-port valves, male threaded, PN25 4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...

More information

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators

Mounting and Operating Instructions EB 3017 EN. Self-operated Regulators Self-operated Regulars Flow and Differential Pressure Regular Type 42-37 Flow and Differential Pressure or Flow and Pressure Regular Type 42-39 Type 42-37 Type 42-39 Fig. 1 Flow and differential pressure

More information

CLASS TLP Pressure Reducing Valve

CLASS TLP Pressure Reducing Valve CLASS TLP Pressure Reducing Valve CLASS TLP Direct Acting Pressure Reducing Valve The Class TLP balanced direct acting pressure regulator is designed for use on installations that have varying inlet pressures

More information

Installation, operation & maintenance manual - original version

Installation, operation & maintenance manual - original version Installation, operation & maintenance manual - original version AVK gate valves for water and wastewater Series 01, 02, 06, 12, 15, 18, 20, 26, 32, 33, 36, 38, 50, 55 and 636 COPYRIGHT AVK GROUP A/S 2018

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

DS06D,G Dial Set Pressure Regulating Valve

DS06D,G Dial Set Pressure Regulating Valve DS06D,G Dial Set Pressure Regulating Valve PRODUCT DATA FEATURES APPLICATION Built-in, factory-calibrated outlet pressure adjustment dial. Noncorroding unitized cartridge contains all working parts and

More information

PRESSURE REDUCING VALVE EUROBRASS 143 FF

PRESSURE REDUCING VALVE EUROBRASS 143 FF Scheda prodotto Eurobrass 143 ENG Rev. 5 09/2012 PRESSURE REDUCING VALVE EUROBRASS 143 FF Direct acting brass pressure reducing valve; PN 25; Adjustable outlet pressure between 0,5 and 6 bar; Brass diaphragm

More information

SEries 29 Hydrant valves installation, operation & maintenance manual

SEries 29 Hydrant valves installation, operation & maintenance manual Instruction for use Thank you for selecting an AVK product. With correct use, it will give long and reliable service. This manual has been prepared to assist you install, operate and maintain the valve

More information

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity

Mounting and Operating Instructions EB EN. Type Supply Pressure Regulator. with increased air capacity Type 4708-45 Supply Pressure Regulator with increased air capacity Translation of original instructions Mounting and Operating Instructions EB 8546-1 EN Edition March 2016 Note on these mounting and operating

More information

FIREFIGHTING EQUIPMENT

FIREFIGHTING EQUIPMENT FIREFIGHTING EQUIPMENT User Manual DEBIKA-INOX Diffuser with adjustable flow & stream settings DOC 1964 En Rev.A - 23/10/13 Identification Product Type Product DESIGNATION Product Reference concerned by

More information

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable!

FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable! FITTINGS AND VALVES Düker Plunger Valve RKV Type 7015 Professional control of flow rates, reservoir levels and pressures Safe, hygienic and durable! 1 The New Düker Plunger Valve Type 7015 St Plunger valves

More information

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator

Mounting and Operating Instructions EB 2558 EN. Self-operated Pressure Regulators. Type Pressure Build-up Regulator Self-operated Pressure Regulators Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Type 2357-31 with non-return unit at port C Ports A and B with soldering

More information