ACCREDITED. Technical specifications series
|
|
- Bartholomew Pearson
- 6 years ago
- Views:
Transcription
1 nti-pollution check valves series REITE ISO 0 FM LEFFI 000/ G replaces dp 000/0G Function The anti-pollution check valve is a protective plumbing device capable of preventing the backflow of polluted water into the mains water system. This may occur due to changes in pressure in the distribution network that cause water to flow backwards. The check valve, which is fitted between the mains and the user system in water distribution systems, prevents any contact between the water in the two systems, as it closes automatically whenever backflow conditions occur. The 0 and 0 series of anti-pollution check valves are certified as being compliant with the performance specifications set out in European standard EN 99. Product range 0 series ontrollable check valve, E type sizes /, /,, /, /, ode 00 ompact controllable check valve, E type size / 0 series ontrollable check valve, E type sizes /,, /, /, 0 series ngled controllable check valve, E type sizes /, 0 series Non-controllable check valve, E type sizes /, /, 0 series ontrollable double check valve sizes /, / ode 00 ontrollable ball valve with approved built-in check valve size / ode 0 ontrollable check valve, E type size / Technical specifications series Materials ody: brass EN WN brass EN WN heck valve: POM POM Springs: stainless steel stainless steel O-Ring seals: EPM, NR EPM, NR Union seal: 0 series: non-asbestos fibre NR 0 series: non-asbestos fibre NR Knob: - 0 series: EN WN all: - 0 series: EN WN, chrome-plated all control stem: - 0 series: EN WN all seal seat: - 0 series: PTFE Test port cap: 0/0 series PG0; 0/0 series: PG0 code 00: brass EN WN Performance Medium: drinking water drinking water Maximum working pressure: 0 bar 0 bar Min. opening pressure for check valve: 0, kpa 0, kpa Maximum working temperature: onnections 0 series: / F (N 0) 0 series: / F (N ) (internal check valve N) code 00: / F with union for M (N ) 0 series: /, / F (N, ) 0 series: / F with union for M (N 0) 0 series: / F with union for M (N ) code 0: / F with captive nut for M (N ) code 0: F with captive nut for M (N ) code 0: / F with captive nut for M (N ) Test port connections / F; code 00: / F 0/0 series: / F
2 imensions ode /" /" " /" /" " 0 0,,, 0 0 0, 0, 0,0 0,, 0 0 ode /" " /" /" " 0,,, 0 0, 0, 0,0,0,0 0 ode 00 /" 0, 0 E 0,0 ode /" /" " 0, 0, ode /" /" 0, 0,,, * Internal check valve N o ode 00 /" 0,, 9 E F G 0, 0, ode 0 0 /" " 0, 0, /" " ode 0 /", E 0,
3 ackflow Potable water, flowing in the mains supply network, may suffer from hazardous pollution mainly caused by the return of contaminated medium from downstream systems directly connected to the main supply. This phenomenon, termed backflow, occurs when: a) the pressure in the mains system is lower than the pressure in the downstream hydraulic circuit (back siphonage). This situation may occur when there is a pipe breaking in the mains system or when demand on the mains supply network by consumers is very heavy. b) the pressure in the downstream circuit rises (counter pressure/downstream overpressure) due, for example, to the inlet of water pumped from a well. ack siphonage Use of type E - E anti-pollution check valves European reference standards EN and EN 99 The use of E and E type anti-pollution check valve is regulated by the new European standards relating to the prevention of pollution caused by backflow. The reference standard is EN : 00 Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow. This standard classifies the water in the systems according to the level of risk it represents for human health. ategory : Water to be used for human consumption coming directly from a potable water distribution system. ategory : Fluid presenting no human health hazard, as per, the quality of which can have undergone a change in taste, odour, colour or temperature. ategory : Fluid representing some human health hazard due to the presence of one or more harmful substances. ategory : Fluid presenting a human health hazard due to the presence of one or more toxic or very toxic substances or one or more radioactive, mutagenic or carcinogenic substances. ownstream overpressure * positive action Risk assessment Given the potential danger of the phenomenon and the requirements of current regulations, the risk of pollution by backflow must be assessed on the basis of the type of system and the characteristic of the medium that flows in it. n appropriate backflow prevention device must be selected on the basis of that assessment performed by the system designer and the mains supply ompany. The device must be located along the supply line at those points at risk of backflow which would be hazardous to human health. ategory : Fluid presenting a human health hazard due to the presence of microbiological or viral elements. ccording to this classification, suitable backflow prevention devices must be fitted in water distribution circuits. E and E type anti-pollution check valves can be used to offer protection against the risk of water contamination up to category. For category water, it is necessary to use a type backflow preventer. The table below, called the Protection matrix, associates the various types of system with the related fluid categories, and was created based on the indications provided in European standard EN and in Local Regulations. The table is not comprehensive, and checks should conducted at the time of application to ensure compliance with any local standards or regulations. The European standard EN 99 nti-pollution check valves from N to N 0. Family E, type,, and. defines the functional, dimensional and mechanical requirements of anti-pollution check valves. Protection matrix System type at. medium General Hot and cold water mixing devices in domestic water systems * Water cooling devices for air conditioning units, without additives * Filling of heating systems, without additives * omestic water softeners regenerated with common salt * ommercial water softeners (only regenerated with common salt) * Water in sinks, baths and showers * omestic dishwashers and washing machines * omestic, residential or commercial gardens Hand-held fertiliser sprayers for use in domestic gardens * atering utomatic dispensers without injection of ingredients or O * Ice-making machines * Large kitchen machines with automatic filling systems * Medical omestic dialysis machines *
4 LEFFI F N Operating principle The anti-pollution check valve consists of a valve body (), a check valve () and, if necessary, one or more inspection points () for operation checking and system draining procedures. The check valve () separates two different zones: one upstream or at the inlet (), and one downstream or at the outlet (). orrect flow conditions In correct flow conditions, the check valve () opens automatically when the pressure in the flow direction upstream () is greater than the downstream value (). onstruction details Hydraulic seal devices When the flow stops, the check valve rests on a lip-shaped EPM seal () which guarantees watertightness, even in the absence of counter pressure. In the event of strong back pressure, the obturator () alters the shape of the seal and rests on the actual end point. This solution guarantees optimal device durability. UPSTREM NORML OPERTION OWNSTREM No flow conditions The check valve () closes in advance under the action of the force exerted by the spring when the pressure downstream () begins to equal the value upstream (), after the flow has stopped. Elastomers complying with food regulations The elastomers used for the hydraulic seals have been approved by the ertifying uthorities in accordance with the most recent provisions regarding compatibility for use with drinking water. Versions with adjustable nut These versions are designed specifically for installation downstream of the water meter. The adjustable nut should be mounted directly over the body of the meter. UPSTREM NO FLOW ONITION OWNSTREM ouble check valve, 0 series The range of products also includes the double check version () and (), with inspection point (). Upstream pressure loss The check valve () remains closed, preventing water which has already been sent to the user from flowing back towards the mains water system. UPSTREM OWNSTREM UPSTREM PRESSURE LOSS ownstream pressure increase If the pressure in the downstream zone () increases until it exceeds the upstream pressure value (), the check valve () remains closed, thus preventing water that has already been sent to the user from flowing back towards the public network. The double check valve may be used, where permitted by current local legislation, as an alternative to the backflow preventer, whenever the water distribution mains has low inlet pressure. The sealing-tightness of the check valve, furthermore, can be tested using the pressure test port in the valve body. ertification The anti-pollution check valves in the 0 and 0 series have been certified as compliant with specific national and European product standards laid down by the following bodies: NF - ELGQU - S. The 0, 0 and 0 series are S-certified.
5 N F N F LEFFI Hydraulic characteristics p (m w.g.) 0 9,,,,,,, 0,9 0. 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, Series* NF LEFFI LEFFI LEFFI LEFFI 0, 0, 0, 0, 0, 0,9 LEFFI N,,,,, N 0,, 9 0 N N 0 N N N p (kpa) ,,, 00 G (m /h) p (m w.g.) 0 9,,,,,,, 0,9 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, NF LEFFI 0, 0, 0, 0, 0, 0, 0, 0, 0,9,,,,, N,, N 9 p (kpa) ,,, 0 Series** Internal check valve N Kv (m /h),0,0 ** double check valve G (m /h) Internal check valve N Kv (m /h) * single check valve Installation and operation checking procedure E E TYPE Installation efore installation, make sure that the device is suitable for protecting the supply system, in relation to the type of fluid used in the system. The controllable check valve should be installed in an accessible position downstream of a shut-off valve. efore installing the backflow preventer flush the pipe with a high capacity WTER MINS Upstream shut-off valve SYSTEM flow rate: the lack of cleaning can easily result in impaired operation of the product. Inspection and maintenance (operation check) procedures should be carried out at least once a year, in accordance with EN 0-. Inspection heck whether the installation standards still require the application of the same device for the type of fluid used in the system. Make sure that the hazard level of the fluid inside the system has not altered over time. heck that the surrounding environment is clean, the valve is accessible and that there are no leaks, corrosion or deterioration. Maintenance (operation check) To test the seal of the check valve, check that the valve closes each time the pressure in the upstream water supply so as to prevent water from the installation flowing back into the supply system: a) to maintain pressure in the installation in the absence of flow, close all shut-off valves or users downstream of the valve. Using the downstream test port (), check that the pressure is greater than 0, bar. b) close the shut-off valve upstream () and open the test port () of the check valve. The flow should stop once the upstream section of pipe has emptied; c) if not, check the sealing-tightness of the upstream shut-off valve (): if this valve is sealing correctly but the flow from the test port () continues, replace the check valve, as the flow can only be caused by imperfect sealing of the valve; d) test port () (if present) can be used with a pressure gauge to test system pressure downstream of the check valve. NF LEFFI ontrollable check valve - Pressure test ports E TYPE Installation The E check valve installation procedure is the same as that for the E valve. Inspection and maintenance (operation check) Inspection and operation check procedures should be carried out at least once a year, in accordance with EN 0-. Inspection The E check valve inspection procedure is the same as that for the E valve. Maintenance (operation check) Replace the valve every 0 years.
6 SPEIFITION SUMMRY 0 series ontrollable check valve. E type. / threaded connections (from / to ) F, internal check valve N (from N to N 0). ertification to EN 99. rass body. POM check valve. Stainless steel spring. EPM and NR O-Ring seals. Medium drinking water. Maximum working pressure 0 bar. Minimum opening pressure for check valve 0, kpa. Maximum working temperature. Test port caps in PG0, / F connections. ode 00 ontrollable check valve. E type. Threaded / F union connections for M, internal check valve N. ertification to standard EN 99. rass body. POM check valve. Stainless steel spring. EPM and NR O-Ring seals. Non-asbestos fibre NR union seal. Medium drinking water. Maximum working pressure 0 bar. Minimum opening pressure for check valve 0, kpa. Maximum working temperature. Test port caps in brass, / F connections. 0 series ontrollable check valve. E type. Threaded / F union connections for M (from / to ) F, internal check valve N (from N to N 0). ertification to EN 99. rass body. POM check valve. Stainless steel spring. EPM and NR O-Ring seals. Non-asbestos fibre NR union seal. Medium drinking water. Maximum working pressure 0 bar. Minimum opening pressure for check valve 0, kpa. Maximum working temperature. Test port caps in PG0, / F connections. ode 0-0 ontrollable check valve with angled connections. E type. / (and ) F threaded connections with captive nut for M, internal check valve N (and N ). ertification to EN 99. rass body. POM check valve. Stainless steel spring. EPM and NR O-Ring seals. Non-asbestos fibre NR union seal. Medium drinking water. Maximum working pressure 0 bar. Minimum opening pressure for check valve 0, kpa. Maximum working temperature. Test port caps in PG0, / F connections. ode 0 ontrollable check valve. E type. / F threaded connections with captive nut for M, internal check valve N. ertification to standard EN 99. rass body. POM check valve. Stainless steel spring. EPM and NR O-Ring seals. Non-asbestos fibre NR union seal. Medium drinking water. Maximum working pressure 0 bar. Minimum opening pressure for check valve 0, kpa. Maximum working temperature. Test port caps in PG0, / F connections. 0 series Non-controllable check valve. E type. / threaded connections (from / to ) F, internal check valve N (from N to N ). rass body. POM check valve. Stainless steel spring. EPM O-Ring seals. Medium drinking water. Maximum working pressure 0 bar. Minimum opening pressure for check valve 0, kpa. Maximum working temperature. 0 series ontrollable double check valve. / (and / ) F threaded connections, internal check valve N (and N ). rass body. POM check valve. Stainless steel spring. EPM and NR O-Ring seals. Medium drinking water. Maximum working pressure 0 bar. Minimum opening pressure for check valve 0, kpa. Maximum working temperature. Test port cap in PG0, / F connection. ode 00 ontrollable ball valve with approved built-in check valve. Threaded / F union connections for M, internal check valve N. rass body. POM check valve. Stainless steel spring. EPM and NR O-Ring seals. Non-asbestos fibre NR union seal. rass knob. rass ball, chrome plated. rass ball control stem. PTFE ball seal seat. Medium drinking water. Maximum working pressure 0 bar. Minimum opening pressure for check valve 0, kpa. Maximum working temperature. Test port caps in PG0, / F connections. We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. aleffi S.p.. S.R. 9 no. 00 Fontaneto d gogna (Novara) Italy Tel Fax +9 0 info@caleffi.com opyright aleffi
CALEFFI. Reduced pressure zone backflow preventer. 574 series 01022/18 NA D E C F B D E. Function
Reduced pressure zone backflow preventer series LEFFI 01022/18 N REITE ISO 9001 FM 216 ISO 9001 No. 000 Function The backflow preventer can be used in all plumbing systems where there is danger of the
More informationACCREDITED H series Inclined pressure reducing valve sizes DN 15 (1/2 ) and DN 20 (3/4 )
Inclined pressure reducing valves 533..H series RIT ISO 91 FM LFFI /17 G replaces / G Function Pressure reducing valves are installed in residential water systems to reduce and stabilise inlet pressure
More informationCALEFFI. Inclined pressure reducing valves series 01024/17 GB. replaces 01024/14 GB
Inclined pressure reducing valves 533 series RIT ISO 91 FM 15 LFFI /17 G replaces /1 G Function Pressure reducing valves are installed in residential water system to reduce and stabilise inlet pressure
More informationACCREDITED. Function. series 5360/
Pressure reducing valves series 360-36 - 36-366 RIT ISO 900 FM 6 LFFI 06/7 G replaces dp 06/0 G Function Pressure reducing valves are devices which, when installed on a private plumbing system, reduce
More informationMaterials : Brass body dezincification-resistant
Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 3/4" Female female BSP + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass body dezincification-resistant Non Controlable With female
More informationInstallation, commissioning and servicing instructions
3838.10 www.caleffi.com Inclined pressure reducing s opyright 2018 aleffi 33 series Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water
More informationCALEFFI. Pre-adjustable pressure reducing valves with self-contained cartridge series 01085/17 GB. replaces 01085/14 GB
Pre-adjustable pressure reducing valves with self-contained cartridge - series CCREDITED ISO 9 FM CLEFFI /7 GB replaces / GB Function Pressure reducing valves are devices which, when installed on private
More informationPressure reducing valves
Pressure reducing valves series 60-6 - 6-66 cert. n 000 ISO 9001 06/01 G Replaces 06/97 G Function Pressure reducers are devices which, when installed on a water system, reduce and stabilise the pressure
More informationFunction. Code Automatic filling units with pressure gauge connection Size 1/2 Code Automatic filling units with pressure gauge Size 1/2
utomatic filling units series 55 cert. n ISO 9 5/5 G Replaces 5/ G unction he automatic filling unit is a device consisting of a pressure reducing valve with compensating seat, an inlet strainer, a shut-off
More informationCALEFFI. Ball zone valves. series /03 GB
all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the
More informationPressure independent control valve (PICV) FLOWMATIC
Pressure independent control valve (PICV) FLOWMATIC 145 series FM 21654 003 01262/19 GB replaces dp 01262/17 GB Function The pressure independent control valve is a device composed of an automatic flow
More informationPre-adjustable pressure reducing valves with self-contained cartridge
Pre-adjustable pressure reducing valves with self-contained cartridge 535..H series ACCREDITED ISO 91 FM 15 15/17 GB replaces 15/1GB Function Pressure reducing valves are devices which, when installed
More informationCALEFFI. DISCAL deaerator. 551 series 01060/17 GB. replaces dp 01060/14 GB
ISL deaerator series RI ISO 900 M 654 LI 0060/7 G replaces dp 0060/4 G unction eaerators are used to continuously remove the air contained in the hydraulic circuits of heating and cooling systems. he air
More informationSerie ECO 3T. Threaded end back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection E U R O P E
Serie ECO T Threaded end back flow preventer with controllable reduced pressure zone BRANDONI made in E U R O P E Application fields WATER FIRE FIGHTING DRINKING WATER 74 www.brandoni.it Serie ECO T The
More informationDN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2
Size : Ends: Min Temperature : Max Temperature : DN 65 to 100 R.F. PN10 flanges + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass check valve Controlable With valves DN1/2 Materials : Bronze body
More informationSerie ECO 3F. Flanged back flow preventer with controllable reduced pressure zone. made in. Application fields. Protection
Flanged back flow preventer with controllable reduced pressure zone made in Application fields WATER FIRE FIGHTING DRINKING WATER 64 www.brandoni.it The ECO 3F flanged backflow preventers, which have a
More informationFunction. brass EN CW617N brass EN CW617N brass EN CW614N. brass EN CW614N brass EN CW617N EPDM
Balancing valves series - cert. n 000 ISO 900 ALEFFI 0/0 GB Function Balancing valves are hydraulic devices that can precisely regulate the flow rate of the fluid that supplies a system s emitters. Hydraulic
More informationCALEFFI. Flow rate metering device. 683 series 01040/10 GB. Function
low rate metering device 683 series CCRI 040/ GB ISO 900 M 64 ISO 900 No. 0003 unction he flow rate metering device is used to measure the flow rate within a circuit. When used for central heating purposes,
More informationMaterials : Brass body dezincification-resistant up to DN1 1/4
Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2" Male, Male BSP + 5 C + 65 C Max Pressure : 10 Bars Specifications : Brass body dezincification-resistant up to DN1 1/4 Controlable With male
More informationTECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS
TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS THE COMPANY ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and
More informationTECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS
TECHNICAL CATALOGUE PRESSURE REDUCING VALVES EUROPRESS ITAP SpA, founded in Lumezzane (Brescia) in 1972, is currently one of the leading production companies in Italy of valves, fittings and distribution
More informationHigh Performance BSP Dial Up Pattern Pressure Reducing Valve
See our full range online at: www.vip-ltd.co.uk High Performance BSP Dial Up Pattern Pressure Reducing Valve VIP Product Code 31/0103 FUNCTION Pressure reducing valves are devices which, when installed
More informationCALEFFI. Motorised temperature regulating unit for heating systems. 167 series 01239/15 GB. replaces dp 01239/13 GB. Function
Motorised temperature regulating unit for heating systems 67 series CCREDITED ISO 9 FM 65 CLEFFI 9/5 G replaces dp 9/ G Function The motorised temperature regulating unit is configured for use with an
More information553 Series.
38467.03 www.caleffi.com Pre-adjustable filling units Copyright 01 Caleffi 3 Series Function The automatic filling valve is a device consisting of a pressure reducing valve with compensating seat, visual
More informationFilling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series
Filling valves AL, ALM Series Automatic filling units ALOMDIW, ALOMDNW Series Main features Designed for automatic filling of sealed heating systems and for protection of the water mains from risk of contamination.
More informationPre-adjustable pressure reducing valves
Pre-adjustable pressure reducing valves H series CCREDITED ISO 9 FM / N Replaces / N Function Pressure reducing valves are devices which, when installed on water systems, reduce and stabilize the pressure
More informationRTG 25. Introduction
Introduction RTG 25 pressure regulator is included within the direct acting and balanced valve regulator class. These regulators have a large range of applications both in industrial and domestic installations.
More informationOverview of types. Technical data. Safety notes
Technical data sheet R2..-S.. Open-close ball valves, 2-way, with internal thread For open and closed cold and warm water systems For shut-off functions on the water side and 2-point controls in U and
More informationInstallation, commissioning and servicing instructions
48323 www.caleffi.com Pre-adjustable pressure reducing valve with self-contained cartridge Copyright 2015 Caleffi 5350..H AUS series Installation, commissioning and servicing instructions Function Pressure
More informationTechnical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3
Technical data sheet R2.. Open-close ball valves, 2-way, with internal thread for open and closed cold and warm water systems for shut-off functions on the water side and 2-point controls in air-handling
More informationInstallation, commissioning and servicing instructions
488.03 www.reece.com.au Pressure reducing s Installation, commissioning and servicing instructions Function Pressure reducing s are installed in residential water systems to reduce and stabilise inlet
More informationPressure regulator for water
Pressure regulator for water rass version with VGW and international drinking water approvals Stainless steel version with VGW approval Compact plastic version Manometer port at pressure output The water
More information2-port and 3-port valves PN 16
OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port
More informationdifferential pressure regulating valve - threaded
140-142 differential pressure regulating valve - threaded Introduction Differential pressure regulating valves (DPRV) maintain the differential pressure across a circuit or sub-branch at a set differential
More informationDIFFERENTIAL PRESSURE ADJUSTMENT Partner valve
alancing part 7 TENIL FOUS DIFFERENTIL PRESSURE DJUSTMENT Partner valve The use of the ΔP regulators to keep the differential constant at the ends of a secondary circuit is usually accompanied by the installation
More informationDUAL CHECK VALVES 2NV20-20F PRODUCT CODES OPERATION LOW HAZARD RATING. 20mm FEATURES APPLICATION SPECIFICATION STATEMENT DESCRIPTION
BACKF PREVENTION DEVICES DUAL CHECK VALVES PRODUCT CODES 20mm FxF Dual Check Valve 20mm FEATURES Protects against back pressure and back siphonage Suitable for low hazard applications Compact and light
More information3-port seat valves with externally threaded connection, PN 16
4 463 Acvatix 3-port seat valves with externally threaded connection, PN 16 VXG41.. ronze CuSn5Zn5Pb2 valve body DN 15 50 k vs 1.6 40 m 3 /h Flat sealing connections with external thread G to ISO 228-1
More informationProducts no longer available
Technical data sheet R2.. Characterized control valves, 2-way, with internal thread for open and closed cold and warm water systems for modulating control on the water side of air-handling and heating
More informationEC 49.0xx.226. Control port. Applications
Solenoid valves Ctrol valves Special valves and systems GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany Tel.: +49(0)211-7391-0 Fax: +49(0)211-7391-281 e-mail: info@akmueller.de Internet: www.akmueller.de
More informationCash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified
Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot
More informationOverview of types. Technical data
Technical data sheet R2..xx-S.. Characterised control valves, 2-way, with internal thread For open and closed cold and warm water systems For modulating water-side control of U and heating systems ir bubble
More informationVG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS
VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal
More informationVG3000. Globe Valves Series for Terminal Units. Product Bulletin. 2-way PDTC (NO) with 6 bar close off pressure. Extend range of K VS
VG3000 Globe Valves Series for Terminal Units Product ulletin The VG3000 brass valve series is primarily designed to regulate the flow of water in response to the demand of a controller in zone and terminal
More informationSYSTEM REGULATING VALVES PRESSURE RELIEF VALVE - SRV BRASS & S/STEEL ADJUSTABLE
SYSTEM REGULATING VALVES PRESSURE RELIEF VALVE - SRV BRASS & S/STEEL ADJUSTABLE This piston style pressure relief valve with conical shaped needle seat for accurate adjustment is available up to 3 in size.
More informationProducts no longer available
Technical data sheet R3 / R3G Change-over ball valve, 3-way, with internal thread for closed cold and warm water systems for switching functions on the water side and 2-point controls in air-handling and
More informationTHE BP-301 SERIES. Operating and Service Manual. Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv)
THE BP-301 SERIES Operating and Service Manual Series includes all variants of BP-301 (LF 0.1Cv / MF 0.5Cv) Issue B October 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation...
More informationTHE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301
THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...
More informationSEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER
SEQUENTIAL SHOWER VALVE INSTRUCTION MANUAL PLEASE LEAVE THIS MANUAL WITH THE END USER CONTENTS 1. INTRODUCTION & SAFETY 1 2. DIMENSIONS 2 3. TECHNICAL DATA 3 4. OPERATION 4 5. COMPONENTS 5 6. SITE INSTALLATION
More informationSelf-operated Pressure Regulators for special applications
Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic
More informationIP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators
L ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification
More informationSRV66 Sanitary Pressure Reducing Valve
1866350/4 IM-P186-09 CH Issue 4 SRV66 Sanitary Pressure Reducing Valve Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Commissioning
More information2-port and 3-port seat valves, PN16
s 4 47 VVI47 VXI47 CVTIX 2-port and 3-port seat valves, PN6 with internally threaded connections VVI47.. VXI47.. ronze valve body CC49K (Rg5) DN 5...5 k vs 2.5...4 m 3 /h Internally threaded connections
More informationReduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections
Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections Features General application The RP03 provides protection from both backsiphonage and backpressure
More informationRS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.
RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to
More informationTHERMOSTATIC MIXING VALVES
THERMOSTATIC MIXING VALVES D1088 & D1089 INTRODUCTION Are self-acting Thermostatic Mixing Valves designed to blend hot and cold water, to ensure a constant, safe outlet temperature and prevent scalding.
More informationFig. Art. 515 121 Pressure reducing valve DVGW approved pressure: max. 25 bar (362,50 psi) Outlet pressure adjustable between 1,5 bar (21,8 psi) and 6 bar (87 psi) Factory pre-set to 4 bar ( psi) Temperature
More informationTHE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401
THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special
More information130400A 1/2 NPT Female A 3/4 NPT Female A 1 NPT Female A 1 1/4 NPT Female A 1 1/2 NPT Female A 2 NPT Female
88.0A www.caleffi.com Venturi Style Balancing Valve Copyright 0 Caleffi 0 Series Function Product Range Balancing valves are hydraulic devices that can precisely control the flow rate of the fluid that
More informationOverview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)
Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating
More informationREDUCED PRESSURE ZONE DEVICES SERIES PRODUCT CODES OPERATION HIGH HAZARD RATING. 15mm - 50mm FEATURES APPLICATION DESCRIPTION
PRODUCT CODES RPZ15DO RPZ20DO RPZ25DO RPZ32DO RPZ40DO RPZ50DO RPZ15 RPZ20 RPZ25 RPZ32 RPZ40 RPZ50 15mm RPZD Device Only 20mm RPZD Device Only 25mm RPZD Device Only 32mm RPZD Device Only 40mm RPZD Device
More informationDN 1/2" to 2" Female BSP + 0 C C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve
Size : Ends : Min Temperature : Max Temperature : DN 1/2" to 2" Female BSP + 0 C + 120 C Max Pressure : 16 Bars Specifications : Stainless steel removable filter Female / Female With draining valve Materials
More informationProduct Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment
Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces
More informationvalves Total Control.
valves Total Control. Contents Tempering Valves 2 Thermostatic Mixing Valves 4 Non-Return Isolating Valves 5 Pressure Reducing Valves 6 Pressure Limiting Valves 8 ackflow Prevention Valves 9 Pressure
More informationDynamic Valve Type RA-DV Pressure Independent Radiator Valve
Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Application RA-DV straight version RA-DV is a series of pressure independent radiator valves, designed for use in 2-pipe heating systems together
More informationVALVCHEQ BACKFLOW PREVENTERS FIGURE RP03
Reduce pressure zone device suitable for high and medium hazard rated applications BSP screwed connections FEATURES GENERAL APPLICATION The RP03 provides protection from both backsiphonage and backpressure
More informationSTAINLESS STEEL OVERFLOW VALVE TYPE 417
MAIN CHARACTERISTICS The 417 valve is intended for the discharge of fluids overflow when an upstream limitation of pressure is looked for, for example downstream to a pump. This valve also works in presence
More informationGREIG FILTERS, INC. OPERATION MANUAL
GREIG FILTERS, INC. OPERATION MANUAL MODEL DCFH 3P 15/3 100 S4 DOE/222 DUAL CARTRIDGE FILTER HOUSING TABLE OF CONTENTS I. INTRODUCTION II. CARTRIDGE FILTER HOUSING UNIT A. OPERATION B. INSTALLATION C.
More informationVersions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions
Ballorex Delta Description The Ballorex Delta is a differential pressure control valve used in hydronic heating or cooling systems. By ensuring a constant differential pressure across motorized or static
More informationPressure Relief Valve DHV 718
Advantages frictionless components low maintenance low pressure increase up to fully opened valve constant low vibration controlling hermetically sealed by diaphragm for oscillating pumps for viscous media
More information6-way characterised control valves DN15 / DN 20 / DN 25
6-way characterised control valves DN15 / DN 20 / DN 25 Table of contents Introduction 2 Project planning 2 Structure of the 6-way characterised control valves 2 Range of use 2 Characteristic curve 3 Flow
More informationAirfix. Flamco. Flamco. Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX D AIRFIX D-E
AIRFIX EXPANSION VESSELS Flamco Airfix Pressure expansion vessels for sanitary appliances and potable water systems AIRFIX A AIRFIX AIRFIX -E Flamco Edition 2005 / EXP Flamco Flamco offers you a wide choice
More information61 Series Pilots for Pilot-Operated Pressure Reducing Regulators
61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally
More informationMark 608. Gas Pressure Regulators. Pressure Regulators Mark 608 Gas Pressure Regulators SPECIFICATIONS (3/4-1-1/4 ) FEATURES 3/4-1-1/4
Mark Gas Pressure Regulators 3/4-1-1/4 The MK Gas Pressure Regulator is the ideal valve for low pressure gas regulation. The self-contained low pressure gas regulator is for use on tank blanketing, gas
More informationInstallation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve
Installation Instructions and User Guide 15mm & 22mm Thermostatic Mixing Valve TMV3 / TMV2 Combined Valve C85079 C85081 C85080 C85082 It is important that these guidance notes are read and fully understood
More informationTwin & Triple Control Concealed Thermostatic Shower Valve
Twin & Triple Control Concealed Thermostatic Shower Valve Installation & Operating Guide Please leave this installation & user guide with the end user CONTENTS: 1. Introduction & Safety 1 2. Dimensions
More informationPressure reducing valves Series DRV/DRVM - DRVN/DRVMN
Pressure reducing valves Series DRV/DRVM - DRVN/DRVMN Main features Pressure reducing valves serve to reduce the pressure of the fluid downstream and to keep it at a constant level by varying its pressure
More informationMODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL
MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL Index 1. List of components / General arrangement 2. Description 3. Handling 4. Installation 5. Actuators / Operation 6. Maintenance a. Changing
More informationshutoff valves 900 Series psig Manual Shutoff Valves
0 6000 psig Manual Shutoff Valves Features Zero leakage Protected o-ring Full flow passages Freedom from wire drawing Panel mount standard Hand wheel or toggle handle How it Works Closed O-ring seal on
More informationRB 4000 Commercial & Industrial Regulator
R 4000 ommercial & Industrial Regulator The R 4000 pressure regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants and all installations where accurate
More informationFILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS
FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.
More informationBERMAD Waterworks. Level Control Valve with Bi-Level Vertical Float. 700 Series Model B. Features and Benefits. Major Additional Features
Level ontrol Valve with i-level Vertical Float Reservoir filling Very low supply-pressure Low noise generation Energy cost-critical systems Systems with poor water quality Reservoir outlet Distribution
More informationBackflow What is it? City Water. Boiler. Make-Up Water Line
Backflow What is it? Backflow? You may have heard of it, and you may understand some of what it involves. This booklet will help you to understand it better; exactly what it is, and how to prevent it.
More information64 Series Pressure Reducing Regulators
Instruction Manual Form 1245 64 Series March 2006 64 Series Pressure Reducing Regulators W1943 Figure 1. 64 Series Regulator Introduction Scope of Manual This manual provides instructions for the installation,
More informationBACK PRESSURE / SUSTAINING
In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series of the OCV control valves.
More informationTECHNICAL DATA. Q = C v P S
Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler
More information1805 Series Relief Valves
October 2011 1805 Series Relief Valves P1026 1805G Type 1805-2 Type 1805-4 Figure 1. Typical 1805 Relief Valves Introduction The 1805 Series relief valves are designed for use in farm tap applications
More informationAnti-flood device Model B-1
December 4, 2009 Dry Systems 123a 1. DESCRIPTION The Anti-flood Device is required when Viking accelerators are installed on dry systems according to Viking Model E-1 Accelerator Trim Charts. In the SET
More informationContents. 1. General information BROEN BALLOMAX Steel Ball Valves Approvals Quality Management...2
Contents 1. General information...2 1.1 BROEN BALLOMAX Steel Ball Valves...2 1.2 Approvals...2 1.3 Quality Management...2 2. Preoperational Instructions and Precautions...2 3. Plates...3 4. Transport and
More informationMounting and operating instructions EB 2530 EN. Self-operated Pressure Regulator. Pressure Reducing Valve Type M 44-2
Self-operated Pressure Regulator Pressure Reducing Valve Type M 44-2 Type M 44-2, connection G 1 4, K VS = 0.15 Type M 44-2, connection G 1, K VS = 6 Fig. 1 Type M 44-2 Pressure Reducing Valve Mounting
More information1200 Series Pressure Regulators
SEE MORE AT SORInc.com Request Quote 1200 Series Pressure SOR pressure regulators are durable, high performing instruments that are designed to provide reliable control of pressure in various stages of
More informationPULSAR4 Pressure regulating valve (Unloader)
Ultimo aggiornamento: 20/04/18 PULSAR4 Pressure regulating valve (Unloader) At gun closure, the waterflow is discharged in bypass reducing the pressure in the system upstream of the valve. Technical manual:
More informationPressure relief valve DHV 716 set range: 0,5-10,0 bar
Pressure relief valve DHV 7 set range: 0,5-0,0 bar Advantage pressure setting possible at any time, also during operation optimum monitoring valves high reproducibility of the set pressure high level of
More informationBACK PRESSURE / SUSTAINING
SPECIFICATIONS DIMENSIONS In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. This is the function of the 108 Pressure Relief / Back Pressure Series
More informationFULL FLOW GAS BALL VALVES: LONDON EN 331 APPROVED. GAS BALL VALVES
FULL FLOW GAS BALL VALVES: EN 331 APPROVED. GAS BALL VALVES 066 BALL VALVE, FULL FLOW SIZE PRESSURE CODE PACKING 1/4" (DN 8) 5bar/72,5psi 066B014 12/192 3/8" (DN ) 5bar/72,5psi 066B038 12/192 1/2" (DN
More informationTECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY
Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More informationBASIN AND WALL MIXER INSTALLATION INSTRUCTIONS
BASIN AND WALL MIXER INSTALLATION INSTRUCTIONS IMPORTANT INFORMATION IMPORTANT All tapware and showers to be installed by a licensed plumber and to Australian Standards. Fit tempering and pressure reduction
More informationPressure relief valve DHV 712 DN 65-80: 0,5-10 bar, DN : 0,3-4 bar, DN 100: 0,5-6 bar
Pressure relief valve DHV 7 DN 5-80: 0,5-0 bar, DN 5-00: 0, - bar, DN 00: 0,5 - bar Advantage for high pressure stability reliable reduction of pressure peaks and pulsations pressure setting possible at
More informationTECHNICAL DATA. Q= Cv S
Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry
More information2-port seat valves PN25 with externally threaded connections
4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with
More informationBERMAD Waterworks. Combination Air Valve. Air Valves Series. Typical Applications. Features & Benefits. Additional Features.
BERMA Waterworks Combination Air Valve Model C7 BERMA C7 is a high quality combination air valve for a variety of water networks and operating conditions. It evacuates air during pipeline filling, allows
More information