52202/52203 Tipping Bucket Raingauge

Size: px
Start display at page:

Download "52202/52203 Tipping Bucket Raingauge"

Transcription

1 52202/52203 Tipping Bucket Raingauge User Manual Issued Copyright Campbell Scientific Ltd. CSL 382

2

3 Guarantee This equipment is guaranteed against defects in materials and workmanship. This guarantee applies for twelve months from date of delivery. We will repair or replace products which prove to be defective during the guarantee period provided they are returned to us prepaid. The guarantee will not apply to: Equipment which has been modified or altered in any way without the written permission of Campbell Scientific Batteries Any product which has been subjected to misuse, neglect, acts of God or damage in transit. Campbell Scientific will return guaranteed equipment by surface carrier prepaid. Campbell Scientific will not reimburse the claimant for costs incurred in removing and/or reinstalling equipment. This guarantee and the Company s obligation thereunder is in lieu of all other guarantees, expressed or implied, including those of suitability and fitness for a particular purpose. Campbell Scientific is not liable for consequential damage. Please inform us before returning equipment and obtain a Repair Reference Number whether the repair is under guarantee or not. Please state the faults as clearly as possible, and if the product is out of the guarantee period it should be accompanied by a purchase order. Quotations for repairs can be given on request. It is the policy of Campbell Scientific to protect the health of its employees and provide a safe working environment, in support of this policy a Declaration of Hazardous Material and Decontamination form will be issued for completion. When returning equipment, the Repair Reference Number must be clearly marked on the outside of the package. Complete the Declaration of Hazardous Material and Decontamination form and ensure a completed copy is returned with your goods. Please note your Repair may not be processed if you do not include a copy of this form and Campbell Scientific Ltd reserves the right to return goods at the customers expense. Note that goods sent air freight are subject to Customs clearance fees which Campbell Scientific will charge to customers. In many cases, these charges are greater than the cost of the repair. Campbell Scientific Ltd, Campbell Park, 80 Hathern Road, Shepshed, Loughborough, LE12 9GX, UK Tel: +44 (0) Fax: +44 (0) support@campbellsci.co.uk

4

5 PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell Scientific Inc. primarily for the North American market. Some spellings, weights and measures may reflect this origin. Some useful conversion factors: Area: 1 in 2 (square inch) = 645 mm 2 Length: 1 in. (inch) = 25.4 mm 1 ft (foot) = mm 1 yard = m 1 mile = km Mass: Pressure: Volume: 1 oz. (ounce) = g 1 lb (pound weight) = kg 1 psi (lb/in 2 ) = mb 1 UK pint = ml 1 UK gallon = litres 1 US gallon = litres In addition, while most of the information in the manual is correct for all countries, certain information is specific to the North American market and so may not be applicable to European users. Differences include the U.S standard external power supply details where some information (for example the AC transformer input voltage) will not be applicable for British/European use. Please note, however, that when a power supply adapter is ordered it will be suitable for use in your country. Reference to some radio transmitters, digital cell phones and aerials may also not be applicable according to your locality. Some brackets, shields and enclosure options, including wiring, are not sold as standard items in the European market; in some cases alternatives are offered. Details of the alternatives will be covered in separate manuals. Part numbers prefixed with a # symbol are special order parts for use with non-eu variants or for special installations. Please quote the full part number with the # when ordering. Recycling information At the end of this product s life it should not be put in commercial or domestic refuse but sent for recycling. Any batteries contained within the product or used during the products life should be removed from the product and also be sent to an appropriate recycling facility. Campbell Scientific Ltd can advise on the recycling of the equipment and in some cases arrange collection and the correct disposal of it, although charges may apply for some items or territories. For further advice or support, please contact Campbell Scientific Ltd, or your local agent. Campbell Scientific Ltd, Campbell Park, 80 Hathern Road, Shepshed, Loughborough, LE12 9GX, UK Tel: +44 (0) Fax: +44 (0) support@campbellsci.co.uk

6

7 Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat bookmarks tab for links to specific sections. 1. Description Specifications Installation and Siting Choice of Site Installation Unpacking Mounting Levelling Wiring Wiring to a Pulse Channel Wiring to a Control Port Model Raingauge with Heater Datalogger Programming Pulse Channel Example Programs CR1000 Example Program CR200(X) Series Example Program CR10X Example Program Control Port Example CR1000 Example Program CR10X Example Program Maintenance Calibration Advantages and Limitations of a Tipping Bucket Raingauge Figures 1. Dimensions of 52202/52203 Tipping Bucket Raingauge Wiring Diagram for 52202/ Tables 4-1. Wiring for Pulse Channel Input Wiring for Control Port Input Multipliers... 6 i

8

9 52202/52203 Tipping Bucket Raingauges The 522 range consists of two well-designed tipping bucket raingauges, manufactured by R M Young, which meet the specifications of the WMO and combine durable construction with very reasonable cost. The gauge construction makes extensive use of thermoplastic components to give maximum performance with good resistance to corrosion. The incorporates a heater for year-round use in all climates, while the is an unheated version of the same gauge. The gauges can be mounted on a flat level surface or mounted on a 34 mm diameter pole. 1. Description Extensive use is made of thermoplastic components in the manufacture of the gauges which helps to ensure maximum performance and value with minimal maintenance. The gauges have built-in bullseye levelling devices for easy and precise adjustment. 2. Specifications The design uses a proven tipping-bucket mechanism for simple and effective rainfall measurement. The bucket geometry and material are specially selected for maximum water release, thereby reducing contamination and errors. Measured precipitation is discharged through a collection tube (which can then be collected if required) for verification of total rainfall. The heated version should be used in climates where snow and ice are expected. Gauge Catchment Area: 200 cm 2 Resolution: Accuracy: Output: Contact Rating; Operating Temperature: Heater (52202): Power Req. (52202): 0.1 mm per tip 2% up to 25 mm/hour 3% up to 50 mm/hour Magnetic reed switch 24V AC/DC, 500 ma max. -20 C to +50 C (for heated version) Rated 24V AC 18-24V AC, 0.75A min. 1

10 52202/52203 Tipping Bucket Raingauges 3. Installation and Siting 3.1 Choice of Site Site the gauge carefully, avoiding obvious sources of error such as nearby trees or buildings. A useful rule of thumb is that the distance between the gauge and any obstruction should be at least as great as twice the height of the obstruction above the ground. For standard meteorological sites in the UK, the Meteorological Office specify the height at which the rim of a raingauge should be above a short grass surface, and the 52202/52203 should be exposed similarly if measurements are required for comparison with those from agrometeorological or synoptic sites. In some countries it is common practice for the gauge to be mounted above the ground for example with the lip at a height of 1 metre. A suitable 34 mm diameter pole can be used to achieve this requirement. NOTE No two raingauge designs are ever likely to produce identical results, and identical raingauges can give slightly different catches even when sited within a metre of each other. While the 52202/52203 raingauges have been designed for pole mounting, research has shown that a raingauge obstructs the flow of air and that the flow accelerates and turbulence increases over the top of the funnel. This can cause less rain to be collected in the funnel than otherwise would have fallen on the ground. In most cases, this phenomenon is ignored but it may be corrected for arithmetically, or overcome physically either using special wind deflection screens around the gauge or by placing the gauge in a pit so that the rim of the funnel is level with the ground. The pit is covered by a grating to simulate the aerodynamic roughness of the ground surface while preventing any splash into the funnel. There are obvious advantages with this method, but it is not always practical (for example in sites subject to significant snowfall). Further details on the exposure of raingauges are given in HMSO (1956, 1982) and by Rodda (1967). Another useful text on exposure and associated errors is Painter (1976). The gauge should also be sited to avoid possible contamination by falling leaves, dirt or other debris. 3.2 Installation Unpacking Mounting Unpack the raingauge carefully. The model 52202/52203 is fully calibrated by the manufacturer before despatch. The moveable bucket is fitted with a retainer to prevent damage during shipping, and this retainer must be removed during installation, as indicated below. The and raingauges are specifically designed for mounting on a pole or tube of 34 mm outside diameter see Figure 1, below. If required, the pole mounting assembly can be removed and the gauge can be mounted directly to a flat surface using appropriate securing bolts. The base mounting flange is provided with three holes on a 160 mm pitch circle diameter for bolting purposes. The raingauge is a light-weight instrument and it must therefore be bolted down securely. 2

11 User Manual If you need to mount the gauge on concrete, we recommend the use of Rawlbolts. Alternatively, a concrete paving slab may be more convenient as a base, in which case through-bolts or screws are suitable. Whichever is chosen, we recommend the use of large washers to spread the load more evenly around the mounting holes in the plastic base. You will also need to make provision to safely route the cable from its exit beneath the raingauge to the datalogger/enclosure. The raingauge should be mounted on your prepared site as follows: 1. Loosen the three screws that retain the housing to the base assembly, and carefully lift the housing free of the base. 2. Remove the shipping retainer from the bucket and verify that the bucket tips freely. 3a. If you are mounting the gauge on a pole, loosen the retaining clip and slide the base assembly onto the pole. When in the required position tighten the clip to secure the gauge. 3b. If you are mounting the gauge to a flat surface, remove the pole mounting assembly to reveal the flat mounting base. Mount the gauge to the required surface using three appropriate sized bolts. 4. When the gauge is securely mounted adjust the levelling screws until the bulls-eye levelling device is centred. 5. Replace the housing and retighten the screws. NOTE If you are installing the heated version of the gauge, attach an appropriate power supply (rated 0.75A min. at 18-24V) to terminals C & D before the housing is fitted. Figure 1 Dimensions of 52202/52203 Tipping Bucket Raingauge 3

12 52202/52203 Tipping Bucket Raingauges Levelling 4. Wiring NOTE If the raingauge is tilted by more than a few degrees, the bucket mechanism may be thrown out of balance, significantly affecting its calibration. Furthermore, during wind-driven rain the response of a gauge with a tilted funnel collector will vary with wind direction. Check that the raingauge is level frequently see the following sections on maintenance and calibration. The raingauge is supplied with a 6m 4-wire cable, which may be extended if required using screened cable. For most applications the raingauge may be connected directly to a pulse counting input on the datalogger as shown in Figure 2. The red and black wires are only used for the heated gauge. For a very long cable, a significant capacitance can exist between the conductors, which discharges across the reed switch as it closes. As well as shortening the life of the switch, a voltage transient may be induced in any other wires which run close to the raingauge cable each time the gauge tips. If you intend to use a long cable (greater than 30 metres) you should fit a 100Ω series resistor in the cable as close to the gauge as possible as shown in Figure 2, below, in order to protect the reed switch from arcing and to prevent transients. It is best to fit this resistor inside the raingauge to protect it from any possible contamination from rain or snow. Figure 2 Wiring Diagram for 52202/

13 User Manual 4.1 Wiring to a Pulse Channel NOTE When Short Cut software is used to generate the datalogger program, the sensor should be wired to the channels shown on the wiring diagram created by Short Cut. The is typically wired to a datalogger s pulse channel (see Table 4-1). Table 4-1. Wiring for Pulse Channel Input CR800 Colour Description CR1000 CR3000 CR5000 CR500 CR510 CR10X Green Signal Pulse Pulse Channel Channel White Signal G Return Clear Shield G 21X CR7 CR23X Pulse Channel CR200(X) Series P_SW 4.2 Wiring to a Control Port Dataloggers listed in Table 4-2 have the capability of counting switch closures on some of their control ports. When a control port is used, the return from the rain gauge switch must be connected to +5 volts on the datalogger. Table 4-2. Wiring for Control Port Input CR800 Colour Description CR1000 CR3000 CR500 CR510 CR10X CR23X Green Signal Control Port C2/P3 Control Port Control Port White Signal 5 V 5 V 5 V 5 V Return Clear Shield G The CR10 does not support the use of control port inputs with the Pulse Count instruction. 4.3 Model Raingauge with Heater Model has a built-in heater to enable the raingauge to be used all year round in cold climates. The heater can be powered from any 18-24V AC supply. Connect the red wire to the positive and the black wire to the negative terminal. The heater consumes up to 0.75 amps. NOTE The heater is not guaranteed to melt heavy ice concentrations or snow which has filled the bucket area. 5

14 52202/52203 Tipping Bucket Raingauges 5. Datalogger Programming NOTE This section is for users who write their own programs. A datalogger program to measure this sensor can be generated using Campbell Scientific s Short Cut Program Builder software. You do not need to read this section to use Short Cut. Precipitation is measured using a Pulse Count with a switch closure configuration code. The multiplier used in the Pulse Count instruction determines the units in which rainfall is reported (see Table 5-1). Table 5-1. Multipliers Rain Gauge 0.01 in. 1 in. 0.1 mm 1 mm Pulse Channel Example Programs The following example programs use a pulse channel to read the output from the precipitation gauge. The CR1000 example will also work with the CR800, CR850, CR3000, and CR5000. CR9000(X) programming is similar to the CR1000 except it has an additional parameter in the PulseCount instruction to specify the pulse module s slot. The CR10X program will also work with the CR500, CR510, CR10, 21X or CR23X. CR7 programming is similar to the CR10X but has an additional parameter in the PulseCount instruction to specify the slot that the Pulse Card is in CR1000 Example Program 'CR1000 'RM_Young Tipping Blk > P1 ' Wht > ground 'Cabling for heater goes to 24VAC power supply Public Rain_mm Units Rain_mm=mm DataTable(Rain,True,-1) DataInterval(0,60,Min,0) Totalize(1,Rain_mm,FP2,0) EndTable BeginProg Scan(1,Sec,1,0) PulseCount(Rain_mm,1,1,2,0,0.1,0) CallTable(Rain) NextScan EndProg 6

15 User Manual CR200(X) Series Example Program 'CR200(X) Series 'RM_Young Tipping Blk > P_SW ' Wht > ground 'Cabling for heater goes to 24VAC power supply 'Declare Variables and Units Public Rain_mm Units Rain_mm=mm 'Define Data Tables DataTable(Rain,True,-1) DataInterval(0,60,Min) Totalize(1,Rain_mm,0) EndTable 'Main Program BeginProg Scan(1,Sec) '52202 Rain Gauge measurement Rain_mm: PulseCount(Rain_mm,P_SW,2,0,0.1,0) 'Call Data Tables and Store Data CallTable(Rain) NextScan EndProg 7

16 52202/52203 Tipping Bucket Raingauges CR10X Example Program ;{CR10X} *Table 1 Program 01: Execution Interval (seconds) 1: Pulse (P3) 1: 1 Reps 2: 1 Pulse Channel 1 3: 2 Switch Closure, All Counts 4: 3 Loc [ Rain_mm ] 5: 0.1 Multiplier 6: 0 Offset 2: If time is (P92) 1: 0 Minutes (Seconds --) into a 2: 60 Interval (same units as above) 3: 10 Set Output Flag High (Flag 0) 3: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 101 Array ID 4: Real Time (P77) 1: 1220 Year,Day,Hour/Minute (midnight = 2400) 5: Totalize (P72) 1: 1 Reps 2: 3 Loc [ Rain_mm ] *Table 2 Program 01: 0 Execution Interval (seconds) *Table 3 Subroutines End Program 5.2 Control Port Example The following example programs use a control port to read the output from the precipitation gauge. The CR1000 example will also work with the CR800, CR850, and CR3000. The CR10X program will also work with the CR500, CR510, or CR23X. 8

17 User Manual CR1000 Example Program 'CR1000 'RM_Young Tipping Blk > C4 ' Wht > 5v 'Cabling for heater goes to 24VAC power supply 'Declare Variables and Units Public BattV Public Rain_mm Units BattV = Volts Units Rain_mm = mm DataTable(OneMin,True,-1) DataInterval(0,1,Min,10) Totalize (1,Rain_mm,FP2,False) EndTable 'Define Data Tables DataTable(OneDay,True,-1) DataInterval(0,1440,Min,10) Minimum(1,BattV,FP2,False,False) Totalize (1,Rain_mm,FP2,False) EndTable 'RM Young tipping bucket 'Main Program BeginProg Scan(5,Sec,1,0) 'Default Datalogger Battery Voltage measurement BattV PanelTemp (PTemp,_50Hz) Battery(BattV) 'RM Young Heated Rain Gauge measurement Rain_mm PulseCount(Rain_mm,1,14,2,0,0.1,0) 'Call Data Tables and Store Data CallTable(OneMin) CallTable(OneDay) NextScan EndProg 9

18 52202/52203 Tipping Bucket Raingauges CR10X Example Program ;{CR10X} ; *Table 1 Program 01: 1 Execution Interval (seconds) 1: Pulse (P3) 1: 1 Reps 2: 8 Control Port 8 (switch closure only) ;Black wire connect to C8 3: 2 Switch Closure, All Counts 4: 1 Loc [ Rain_mm ] Multiplier 6: 0 Offset 2: If time is (P92) 1: 0 Minutes (Seconds --) into a 2: 60 Interval (same units as above) 3: 10 Set Output Flag High (Flag 0) 3: Set Active Storage Area (P80) 1: 1 Final Storage Area 1 2: 101 Array ID 4: Real Time (P77) 1: 1220 Year,Day,Hour/Minute (midnight = 2400) 5: Totalize (P72) 1: 1 Reps 2: 1 Loc [ Rain_mm ] *Table 2 Program 02: Execution Interval (seconds) *Table 3 Subroutines End Program Output Instruction 72, Totalize, is used in the output section of the program to output the total rainfall over the output interval. This section should be executed every scan and not placed in a subroutine or conditional statement. 6. Maintenance To ensure reliable and accurate measurements, we recommend that the following checks be carried out every month if possible: 1. Inspect the funnel for any damage or blockage and check the integrity of the connecting cable. At certain times of the year, leaves may accumulate in the bottom of the funnel, clogging the filter and preventing the flow to the buckets beneath, or reducing the flow rate to a slow drip. The obstruction is best cleared by inverting the funnel (after removal from the base) and pouring water back through from the spout beneath the collecting surface. 2. Check that the gauge is still level. It is surprisingly easy for an apparently immovable gauge to become tilted as a result of small ground movements, vandalism or just inquisitive fingers. 10

19 User Manual 3. Check the movement of the tipping bucket and the functioning of the gauge. This can be done by slowly pouring a measured quantity of water (say 100 ml) through the gauge and counting the tips see calibration section below. It is worthwhile carrying this out at regular weekly intervals (for example, every Monday at 0900) while leaving the gauge connected to the datalogger. Providing a significant volume of water is used, these weekly checks can easily be identified in the logged measurements. This simple procedure confirms that the gauge is functioning, detects any marked change in the calibration and (if carried out punctually) introduces an independent time check into the records. 7. Calibration To check or recalibrate the raingauge, the following steps are suggested: 1. With the raingauge properly levelled, slowly drip a measured volume of water into the collection funnel at a rate of approximately 3.3 ml per minute. This is equivalent to a rainfall of 10 mm/hour, as recommended in BS7843 Section 2.1 for calibration of tipping bucket raingauges. 2. Carefully count how many times the bucket tips it should tip five times for each 10 ml of water. For example, if you use 100 ml of water the bucket should tip approximately 50 times. You can count the number of tips manually or with a datalogger connected to the raingauge. 3. If the count shows an error of more than 2%, adjust the calibrating screws to correct the error raise the screws if the count is low, lower the screws if the count is high. Always adjust both screws equally. This type of dynamic calibration gives repeatable results in a test environment, but it is not a true representation of the gauge s sensitivity to natural precipitation. When used in the UK useful results can be obtained by comparing the output from the 52202/52203 with the catches from a standard Snowdon pattern gauge (HMSO, 1956) sited nearby. If this comparison is carried out with care, a calibration factor for natural rainfall can be calculated from the slope of a graphical plot of (number of tips) against (catch from Snowdon gauge in mm). 8. Advantages and Limitations of a Tipping Bucket Raingauge Gauges which operate on the tipping bucket principle provide a digital output, which simplifies connection to a datalogger. The pulses returned during rainfall may be counted over any time interval desired allowing accurate determination of the rainfall rate (this variable, sometimes called intensity, is frequently used in soil erosion studies and is relevant to some aspects of crop pathology). A tipping bucket gauge responds to discrete quanta of rainfall, and the accuracy and reproducibility of this quantum are determined not only by factors such as friction in the bearings, etc. but also by the rate of fill of the buckets. When the rainfall rate is high, a bucket may start to tip when the necessary volume of water has been collected, but while the bucket is moving away from the funnel outlet, an extra volume will have been collected and lost through spillage. The resulting degradation in accuracy is of the order of 4% at rainfall rates of 25 mm/hr and 8% at 133 mm/hr for most gauges (Parkin et al, 1982). This is important when results from gauges of different designs are compared. These errors worsen when gauge sensitivity is increased. It follows that gauge design is always a compromise between the need for good resolution and good overall accuracy in rainfall totals. 11

20 52202/52203 Tipping Bucket Raingauges References HMSO (1956) Handbook of Meteorological Instruments, Part 1, Met HMSO (1982) Observers Handbook, Met Painter, R.D. (1976) in Methods of Plant Ecology pp Ed. by S.B.Chapman, Blackwell Scientific Press, Oxford Parkin, D.A., King, W.D. and Shaw, D.E. (1982) An automatic raingauge network for a cloud seeding experiment J.Appl.Meteorol. p 228. Rodda, J.C., (1967) The rainfall measurement problem Proc. IAHS Gen. Ass. Bern, IAHS Pub. No. 78,

21

22 CAMPBELL SCIENTIFIC COMPANIES Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah UNITED STATES Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444 Thuringowa Central QLD 4812 AUSTRALIA Campbell Scientific do Brazil Ltda. (CSB) Rua Luisa Crapsi Orsi, 15 Butantã CEP: São Paulo SP BRAZIL Campbell Scientific Canada Corp. (CSC) th Street NW Edmonton, Alberta T5M 1W7 CANADA Campbell Scientific Centro Caribe S.A. (CSCC) 300N Cementerio, Edificio Breller Santo Domingo, Heredia COSTA RICA Campbell Scientific Ltd. (CSL) Campbell Park 80 Hathern Road Shepshed, Loughborough LE12 9GX UNITED KINGDOM Campbell Scientific Ltd. (France) 3 Avenue de la Division Leclerc ANTONY FRANCE info@campbellsci.fr Campbell Scientific Spain, S. L. Avda. Pompeu Fabra 7-9 Local BARCELONA SPAIN info@campbellsci.es Campbell Scientific Ltd. (Germany) Fahrenheitstrasse13, D Bremen GERMANY info@campbellsci.de Please visit to obtain contact information for your local US or International representative.

INSTRUCTION MANUAL. Tipping Bucket Rain Gauge. Issued: Copyright 2017 Campbell Scientific Ltd. CSL 1194

INSTRUCTION MANUAL. Tipping Bucket Rain Gauge. Issued: Copyright 2017 Campbell Scientific Ltd. CSL 1194 INSTRUCTION MANUAL Kalyx-RG Tipping Bucket Rain Gauge Issued: 17.1.17 Copyright 2017 Campbell Scientific Ltd. CSL 1194 Guarantee This equipment is guaranteed against defects in materials and workmanship.

More information

PWC100 Present Weather Sensor Calibrator

PWC100 Present Weather Sensor Calibrator PWC100 Present Weather Sensor Calibrator User Guide Issued 6.2.12 Copyright 2008-2012 Campbell Scientific Ltd. CSL 801 Guarantee This equipment is guaranteed against defects in materials and workmanship.

More information

PWC100 Present Weather Sensor Calibrator Revision: 3/12

PWC100 Present Weather Sensor Calibrator Revision: 3/12 PWC100 Present Weather Sensor Calibrator Revision: 3/12 Copyright 2008-2012 Campbell Scientific, Inc. PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell

More information

INSTRUCTION MANUAL. CS115 Barometric Pressure Sensor 3/03. Copyright (c) Campbell Scientific, Inc.

INSTRUCTION MANUAL. CS115 Barometric Pressure Sensor 3/03. Copyright (c) Campbell Scientific, Inc. INSTRUCTION MANUAL CS115 Barometric Pressure Sensor 3/03 Copyright (c) 2002-2003 Campbell Scientific, Inc. Warranty and Assistance The CS115 BAROMETRIC PRESSURE SENSOR is warranted by CAMPBELL SCIENTIFIC,

More information

TGA200 Trace Gas Analyzer Overview 9/11

TGA200 Trace Gas Analyzer Overview 9/11 TGA200 Trace Gas Analyzer Overview 9/11 C o p y r i g h t 2 0 1 1 C a m p b e l l S c i e n t i f i c, I n c. Warranty PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific,

More information

INSTRUCTION MANUAL. Using the CS400/CS405 (KPSI Series 169/173) Submersible Pressure Transducer with Campbell Scientific Dataloggers.

INSTRUCTION MANUAL. Using the CS400/CS405 (KPSI Series 169/173) Submersible Pressure Transducer with Campbell Scientific Dataloggers. INSTRUCTION MANUAL Using the CS400/CS405 (KPSI Series 169/173) Submersible Pressure Transducer with Campbell Scientific Dataloggers Revision: 11/02 Copyright (c) 2000-2002 Campbell Scientific, Inc. The

More information

AERODYNAMIC RAIN GAUGE ARG100

AERODYNAMIC RAIN GAUGE ARG100 Streamline Measurement Ltd ARG100 Users Manual AERODYNAMIC RAIN GAUGE ARG100 Streamline Measurement Ltd, 01457-864334, sales@streamlinemeasurement.co.uk, www.streamlinemeasurement.co.uk ARG100 : AERODYNAMIC

More information

Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision: 12/06

Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision: 12/06 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision: 12/06 Copyright 2001-2006 Campbell Scientific, Inc. Warranty and Assistance The CS512 OXYGUARD TYPE III DISSOLVED OXYGEN PROBE

More information

Campbell Scientific CS511-L Sensorex Dissolved Oxygen Probe Revision: 6/12

Campbell Scientific CS511-L Sensorex Dissolved Oxygen Probe Revision: 6/12 Campbell Scientific CS511-L Sensorex Dissolved Oxygen Probe Revision: 6/12 Copyright 2001-2012 Campbell Scientific, Inc. Warranty PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell

More information

aerodynamic rain gauge

aerodynamic rain gauge aerodynamic rain gauge Contents On these operating instructions... 2 1. General description... 2 1.1 Description of the raingauge... 2 1.2 Choosing a site... 2 2. Installation of the raingauge... 3 2.1

More information

ARG 100 Raingauge. SKYE INSTRUMENTS LIMITED 21, Ddole Enterprise Park Llandrindod Wells Powys, LD1 6DF UK TEL: FAX:

ARG 100 Raingauge. SKYE INSTRUMENTS LIMITED 21, Ddole Enterprise Park Llandrindod Wells Powys, LD1 6DF UK TEL: FAX: ARG 100 Raingauge SKYE INSTRUMENTS LIMITED 21, Ddole Enterprise Park Llandrindod Wells Powys, LD1 6DF UK TEL: +44 1597 824811 FAX: +44 1597 824812 General Email: skyemail@skyeinstruments.com Technical

More information

CS511. Dissolved Oxygen Sensor. Revision: 5/18 Copyright Campbell Scientific, Inc.

CS511. Dissolved Oxygen Sensor. Revision: 5/18 Copyright Campbell Scientific, Inc. CS511 Dissolved Oxygen Sensor Revision: 5/18 Copyright 2001 2018 Campbell Scientific, Inc. Guarantee This equipment is guaranteed against defects in materials and workmanship. We will repair or replace

More information

USER MANUAL. CRS451/CRS456 Submersible Water-Level Recording Sensor. Issued:

USER MANUAL. CRS451/CRS456 Submersible Water-Level Recording Sensor. Issued: USER MANUAL CRS451/CRS456 Submersible Water-Level Recording Sensor Issued: 3.11.15 Copyright 2013-2015 Campbell Scientific, Inc. Printed under licence by Campbell Scientific Ltd. CSL 996 Guarantee This

More information

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB305-1MM

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB305-1MM HYDROLOGICAL SEVICES PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB305-1MM QUALITY SYSTEM ISO 9001 2008 CERTIFIED HYDROLOGICAL SERVICES PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA

More information

CS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

CS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL CS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL 3/03 COPYRIGHT (c) 2002-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC

More information

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6 INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB6 QUALITY SYSTEM ISO:9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.)

More information

CS431 Submersible Pressure Transducer Revision: 3/09

CS431 Submersible Pressure Transducer Revision: 3/09 CS431 Submersible Pressure Transducer Revision: 3/09 Copyright 2008-2009 Campbell Scientific, Inc. Warranty and Assistance The CS431 SUBMERSIBLE PRESSURE TRANSDUCER is warranted by CAMPBELL SCIENTIFIC,

More information

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 260-2595 RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL REVISION DATE: August 2018 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify NovaLynx

More information

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB3

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB3 INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB3 QUALITY SYSTEM ISO:9001 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.) 612

More information

INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE. MODEL TB3/0.1mm

INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE. MODEL TB3/0.1mm INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB3/0.1mm QUALITY SYSTEM ISO 9001 2008 CERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax:

More information

USER MANUAL. CS106 Barometric Pressure Sensor. Issued:

USER MANUAL. CS106 Barometric Pressure Sensor. Issued: USER MANUAL CS106 Barometric Pressure Sensor Issued: 12.12.17 Copyright 1995-2017 Campbell Scientific, Inc. Printed under licence by Campbell Scientific Ltd. CSL 713 Guarantee This equipment is guaranteed

More information

DPC-30 DPC-100. Reference Manual

DPC-30 DPC-100. Reference Manual DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,

More information

CS470/CS471 Compact Bubbler System Revision: 7/11

CS470/CS471 Compact Bubbler System Revision: 7/11 CS470/CS471 Compact Bubbler System Revision: 7/11 Copyright 2009-2011 Campbell Scientific, Inc. Warranty and Assistance PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific,

More information

INSTRUCTION MANUAL TIPPING BUCKET RAINGUAGE MODEL TB3

INSTRUCTION MANUAL TIPPING BUCKET RAINGUAGE MODEL TB3 HYDROLOGICAL SEVICES INSTRUCTION MANUAL TIPPING BUCKET RAINGUAGE MODEL TB3 QUALITY SYSTEM ISO 9001 2000 CERTIFIED HYDROLOGICAL SERVICES PTY LTD PO BOX 332, LIVERPOOL B.C NSW 1871, AUSTRALIA Phone:(Int.)

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0545 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB6

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB6 INSTRUTION MANUAL TIPPING BUKET RAINGAUGE MODEL TB6 QUALITY SYSTEM ISO:9001 ERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B. NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.) 612 9602

More information

INSTRUCTION MANUAL. CS106 Barometric Pressure Sensor Revision: 4/17. Copyright Campbell Scientific, Inc.

INSTRUCTION MANUAL. CS106 Barometric Pressure Sensor Revision: 4/17. Copyright Campbell Scientific, Inc. INSTRUCTION MANUAL CS106 Barometric Pressure Sensor Revision: 4/17 Copyright 1995-2 017 Campbell Scientific, Inc. Assistance Products may not be returned without prior authorization. The following contact

More information

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual

TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual Relied on Worldwide in the Most Extreme Conditions TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual Texas Electronics, Inc. Dallas, TX 75237 Fax.214.631.4218 4230 Shilling Way Tel.214-631-2490

More information

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a

USER GUIDE. Fog Generator. ATMOSPHERE APS TM Series Haze Generator. MAX APS TM Series. No: , Revision A/a ATMOSPHERE APS TM Series Haze Generator MAX APS TM Series Fog Generator USER GUIDE No: 120815, Revision A/a MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard Ltée / Fog Generators Ltd 10301

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual WIKA FLR-SBDF / BLR-SBDF Magnetic Level Transmitter (Please retain for future usage) Contact: Gayesco-WIKA USA, L.P. 229 Beltway Green Boulevard Pasadena, TX 77503 www.wika.com

More information

INSTRUCTION MANUAL. CS106 Barometric Pressure Sensor Revision: 4/17. Copyright Campbell Scientific, Inc.

INSTRUCTION MANUAL. CS106 Barometric Pressure Sensor Revision: 4/17. Copyright Campbell Scientific, Inc. INSTRUCTION MANUAL CS106 Barometric Pressure Sensor Revision: 4/17 Copyright 1995-2 017 Campbell Scientific, Inc. Limited Warranty The CS106 Barometric Pressure Sensor is warranted for three (3) years

More information

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT 2013 Universal Remote Control, Inc. The information in this Owner s Manual is copyright protected.

More information

Operating Instructions Part No

Operating Instructions Part No DIGITAL AUTOMATIC TYRE INFLATOR Operating Instructions Part No. 11.0578 Thank you for selecting this Jamec Pem Automatic Tyre Inflator. Please read this manual before carrying out any installation or service

More information

INSTRUCTION MANUAL. CRS451/CRS456 Submersible Water-Level Recording Sensor Revision: 12/15. Copyright Campbell Scientific, Inc.

INSTRUCTION MANUAL. CRS451/CRS456 Submersible Water-Level Recording Sensor Revision: 12/15. Copyright Campbell Scientific, Inc. INSTRUCTION MANUAL CRS451/CRS456 Submersible Water-Level Recording Sensor Revision: 12/15 Copyright 2013-2015 Campbell Scientific, Inc. Limited Warranty Products manufactured by CSI are warranted by CSI

More information

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB4

HYQUEST SOLUTIONS PTY LTD INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL TB4 INSTRUTION MANUAL TIPPING BUKET RAIN GAUGE MODEL TB4 QUALITY SYSTEM ISO:9001 ERTIFIED HYQUEST SOLUTIONS PTY LTD PO BOX 332, LIVERPOOL B. NSW 1871, AUSTRALIA Phone:(Int.) 612 9601 2022 Fax: :(Int.) 612

More information

Agilent 1220 Infinity II LC Mobile Upgrade Kit

Agilent 1220 Infinity II LC Mobile Upgrade Kit Agilent 1220 Infinity II LC Mobile Upgrade Kit Note 1220 Infinity II LC Mobile Upgrade Kit This note describes the procedures to install an Mobile Upgrade kit to an existing Agilent 1220 Infinity II LC.

More information

TV-114 TV-114-A Wind Speed Sensor User s Manual

TV-114 TV-114-A Wind Speed Sensor User s Manual Relied on Worldwide in the Most Extreme Conditions TV-114 TV-114-A Wind Speed Sensor User s Manual Texas Electronics, Inc. Dallas, TX 75237 Fax.214.631.4218 4230 Shilling Way Tel.214-631-2490 www.texaselectronics.com

More information

210 Series Transmitter with External Electrochemical Sensor

210 Series Transmitter with External Electrochemical Sensor 210 Series Transmitter with External Electrochemical Sensor INSTRUCTIONS Installation and Operation of the AMC-210 Series Transmitter with External Electrochemical Sensor IMPORTANT: Please read these installation

More information

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d

USER GUIDE. Fog Generator. ATMOSPHERE APS Series Haze Generator. MAX APS Series. No: , Revision A/d ATMOSPHERE APS Series Haze Generator MAX APS Series Fog Generator USER GUIDE No: 120815, Revision A/d MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard Ltée / Fog Generators Ltd 10301 avenue

More information

RADROVER REAR RACK INSTALLATION MANUAL

RADROVER REAR RACK INSTALLATION MANUAL RADROVER REAR RACK INSTALLATION MANUAL WWW.RADPOWERBIKES.COM We are here to help! Please contact us at SUPPORT@RADPOWERBIKES.COM or 1-800-939-0310 if you have questions. REV022216 Welcome Thanks you for

More information

AA GWR Water Retention Meter for Accurate Measurement of Water Retention

AA GWR Water Retention Meter for Accurate Measurement of Water Retention AA GWR Water Retention Meter for Accurate Measurement of Water Retention Principle of Measurement: Coating color is poured into a test cell and separated from a blotting paper with a filter. The cell is

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document N0. 1800-03 Copyright 2010 Terra Universal Inc. All rights reserved. Revised Sept. 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data

Model B-1 Pipe Line Strainer 3, 4, 6 & 8 Inch (DN80, DN100, DN150 & DN200) 175 psi (12,1 bar) General Description. Technical Data Technical Services: Tel: (800) 381-312 / Fax: (800) 71-5500 Customer Service/Sales: Tel: (215) 362-0700 / (800) 523-6512 Fax: (215) 362-5385 Model B-1 Pipe Line Strainer 3,, 6 & 8 Inch (DN80, DN100, DN150

More information

Installation, operating and maintenance Instructions for Seemag bypass level indicator

Installation, operating and maintenance Instructions for Seemag bypass level indicator Issue: S Date: 05-09-14 Type G35 General information The Seetru bypass magnetic level indicator, abbreviate SEEMAG, serves to show the filling level of fluids in tanks, basins, tubes etc. The Seemag operates

More information

CSBUOY-DT INSTRUCTION MANUAL

CSBUOY-DT INSTRUCTION MANUAL CSBUOY-DT INSTRUCTION MANUAL 5/02 COPYRIGHT (c) 2002 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC (CANADA) CORP. ( CSC ) to

More information

USING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL

USING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL USING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL REVISION: 11/02 COPYRIGHT (c) 2000-2002 CAMPBELL SCIENTIFIC, INC. This

More information

WBEA Standard Operating Procedure

WBEA Standard Operating Procedure Page 1 WBEA Standard Operating Procedure SOP Title Temperature and Relative Humidity Author Gary Cross Implementation date March 2, 2013 Revision History Revision # Date Description Author Page 2 Table

More information

NOVALYNX CORPORATION MODEL BAROMETRIC PRESSURE SENSOR PCB MODEL BAROMETRIC PRESSURE SENSOR IN NEMA ENCLOSURE INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL BAROMETRIC PRESSURE SENSOR PCB MODEL BAROMETRIC PRESSURE SENSOR IN NEMA ENCLOSURE INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 230-600 BAROMETRIC PRESSURE SENSOR PCB MODEL 230-601 BAROMETRIC PRESSURE SENSOR IN NEMA ENCLOSURE INSTRUCTION MANUAL REVISION DATE: 11/15/2006 Receiving and Unpacking Carefully

More information

Model 130M Pneumatic Controller

Model 130M Pneumatic Controller Instruction MI 017-450 May 1978 Model 130M Pneumatic Controller Installation and Operation Manual Control Unit Controller Model 130M Controller is a pneumatic, shelf-mounted instrument with a separate

More information

Marschalk Model # 94000

Marschalk Model # 94000 Marschalk Model # 94000 12-volt DC Portable oil-less Air Compressor Operation Manual 27250006 REV 1 9/13/05 Table of Contents CHAPTER 1: SYSTEM DESCRIPTION... 5 FUNCTION AND THEORY... 5 SYSTEM COMPONENTS...

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230

Instruction Manual. Digital Thermocouple Gauge Control Units Models DTC & DTC Models DTC-06M-115 & DTC-06M-230 Instruction Manual Digital Thermocouple Gauge Control Units Models DTC-531-115 & DTC-531-230 Models DTC-06M-115 & DTC-06M-230 Copyright 1998 by Duniway Stockroom Corp. 021315lh 1 of 7 Table of Contents

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual 1194 Oak Valley Drive, Suite 20, Ann Arbor, MI 48108 800-959-0573 734-769-1888 Content Page For your Safety 3 General Description 3 Detection Principle 4 Operation 4

More information

RGC-IR Remote Gas Calibrator for IR400

RGC-IR Remote Gas Calibrator for IR400 Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) WARRANTY CLAUSE METROSONICS warrants each new cl-304 manufactured and sold to be free from defects in material, workmanship and construction, except for batteries which may be contained therein, and that

More information

The Univentor 1250 Anaesthesia Unit

The Univentor 1250 Anaesthesia Unit THE UNIVENTOR 1200/1250 ANAESTHESIA UNIT The Univentor 1250 Anaesthesia Unit TABLE OF CONTENTS EDITION 1 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

HLM-2000-TX Gas Transmitter User Manual

HLM-2000-TX Gas Transmitter User Manual HLM-2000-TX Gas Transmitter User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay Engineering Ltd. Oakville,

More information

STARLOG. Capacitive Water Depth Probe

STARLOG. Capacitive Water Depth Probe STARLOG Capacitive Water Depth Probe Model 6521 User Manual Supplement 6219 Revision D July 10. 1998 Copyright Notice Copyright Unidata Australia 1998. All rights reserved. No part of this publication

More information

WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES

WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES Christophe ALEXANDROPOULOS and Muriel LACOMBE Météo-France, Direction des Systèmes d Observation, BP 202-78195 Trappes France christophe.alexandropoulos@meteo.fr

More information

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS

Hot Tapping Machine. OPERATIONS MANUAL and OPERATING INSTRUCTIONS 262-2040 Hot Tapping Machine For performing 1/4 6 Hot taps 285 psi or less. Municipal Water, Sewage, & Building Services Use OPERATIONS MANUAL and OPERATING INSTRUCTIONS WARNING: These instructions are

More information

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures MINT-0289-XX TABLE OF CONTENTS Limited Warranty... 3 User Responsibility... 3-4 General Service... 4 Safety Precautions.... 5 Physical Dimensions..

More information

6 digital caliper with case

6 digital caliper with case 6 digital caliper with case Model 98563 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly

More information

Low Wind High Yields Series

Low Wind High Yields Series Low Wind High Yields Series Wind Turbines USER S MANUAL Introduction Low Wind High Yields Series rotor blades apply the latest advanced thermoplastic engineering and are manufactured by precision injection

More information

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Portable Gas Monitor GX User Maintenance Manual (H4-0050) H4E-0050 Portable Gas Monitor GX-8000 User Maintenance Manual (H4-0050) Need of Maintenance and Servicing This gas monitor must be maintained in a normal state at all times to prevent accidents due to

More information

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide

CP-D/CP-M Circular Polarizer for Phoroptor. User s Guide CP-D/CP-M Circular Polarizer for Phoroptor User s Guide 2016 AMETEK, Inc. Reichert, Reichert Technologies, Auto Phoroptor RS and Phoroptor are registered trademarks of Reichert, Inc. Ultramatic RX Master

More information

OWNER S MANUAL FOR THE FOAM MARKER FM24. In-Ex PO Box Harts Road, Tiritea Palmerston North Ph: Fax:

OWNER S MANUAL FOR THE FOAM MARKER FM24. In-Ex PO Box Harts Road, Tiritea Palmerston North Ph: Fax: OWNER S MANUAL FOR THE FOAM MARKER FM24 In-Ex PO Box 1010 145 Harts Road, Tiritea Palmerston North Ph: 06 354 6060 Fax: 06 355 3199 1 SAFETY PRECAUTIONS Warnings are mandatory instructions to prevent serious

More information

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO 400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand

More information

OEM Manual. MODEL ½ Digit DRUM SCALE

OEM Manual. MODEL ½ Digit DRUM SCALE OEM Manual MODEL 4020-3 ½ Digit DRUM SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA & Canada) Phone:

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

HYDROLOGICAL SERVICES INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB4

HYDROLOGICAL SERVICES INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL TB4 HYDROLOGIAL SERVIES INSTRUTION MANUAL TIPPING BUKET RAINGAUGE MODEL TB4 QUALITY SYSTEM ISO 9001 2008 ERTIFIED HYDROLOGIAL SERVIES PTY LTD PO BOX 332, LIVERPOOL B. NSW 1871, AUSTRALIA Phone:(Int.) 612 9601

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

Electro-Pneumatic Converter YT-940 SERIES

Electro-Pneumatic Converter YT-940 SERIES Electro-Pneumatic Converter YT-940 SERIES PRODUCT MANUAL VERSION 1.00 Contents 1. Introduction 3 1.1 General information for the users. 3 1.2 Manufacturer Warranty 3 1.3 Explosion Proof Warning. 4 2. Product

More information

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL WEATHER STATION INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 100-1950 WEATHER STATION INSTRUCTION MANUAL Receiving and Unpacking Carefully unpack all components and compare to packing list. Notify NovaLynx Corporation immediately concerning

More information

PH01 Perfusion Cannula Manual

PH01 Perfusion Cannula Manual PH01 Perfusion Cannula Manual Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted without the express written permission of Multi

More information

ATOC Meteorological Tower (6 meter-4 level) Guide

ATOC Meteorological Tower (6 meter-4 level) Guide ATOC Meteorological Tower (6 meter-4 level) Guide SETUP Outline 1. Siting 2. Components 3. Transportation 4. The Tower 5. The Cables and Data Logger Siting Selecting an appropriate site for the weather

More information

Technical Information Conducal CLY421

Technical Information Conducal CLY421 TI00496C/07/EN/01.12 71142150 Products Solutions Services Technical Information Conducal CLY421 Conductivity calibration set for ultrapure water applications Factory calibrated measurement box Certified

More information

Sensoric 4-20 ma Transmitter Board Operation Manual

Sensoric 4-20 ma Transmitter Board Operation Manual Sensoric 4-20 ma Transmitter Board Operation Manual 1 Content Features Operation Manual Technical Data Mechanical Dimensions Remarks & Contact information 2 Features Soldered sensor cell (non replaceable)

More information

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027

Operating Instructions. Ball valve fitting according to ZB For pressure transmitter VEGABAR 82. Document ID: 50027 Operating Instructions Ball valve fitting according to ZB 2553 For pressure transmitter VEGABAR 82 Document ID: 50027 Contents Contents 1 About this document 1.1 Function... 3 1.2 Target group... 3 1.3

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

! Warning, refer to accompanying documents.

! Warning, refer to accompanying documents. About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions

L 100. Bubble-Tube Level System. Installation, Operation and Maintenance Instructions L 100 Bubble-Tube Level System Installation, Operation and Maintenance Instructions Figure 1 Contents Section Description Page 1.0 Introduction 2 2.0 Specifications 3 3.0 Installation 3 4.0 Warranty 6

More information

Inert Air (N2) Systems Manual

Inert Air (N2) Systems Manual INSTRUCTION MANUAL Inert Air (N2) Systems Manual N2-MANUAL 2.10 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. GENERAL INFORMATION Positive pressure nitrogen gas pressurizing

More information

Air Sensor. FCS Ex. Manual. AQ Elteknik AB

Air Sensor. FCS Ex. Manual. AQ Elteknik AB Air Sensor FCS Ex Manual AQ Elteknik AB Air Sensor Model FCS Ex Manual version 2.0 Oct 2010 AQ Elteknik AB AQ Elteknik AB Air Sensor Manual 2 Table of contents 1. Manufacturer information... 4 Manufacture

More information

2000 lb manual winch

2000 lb manual winch 2000 lb manual winch Model 41694 Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo, CA 93011

More information

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1)

JOLLY2. Installation user s manual. 6 different operating modes selectable. version 3.3. DATA TO BE FILLED OUT BY THE INSTALLER (Page 1) ENGLISH ENGLISH ENGLISH ENGLISH Installation user s manual Warning! electrical scheme modified JANUARY 2005 version 3.3 JOLLY2 DATA TO BE FILLED OUT BY THE INSTALLER (Page 1) 6 different operating modes

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

Rugged Powered Bin Lifter. Operating Manual

Rugged Powered Bin Lifter. Operating Manual Rugged Powered Bin Lifter Operating Manual Rugged Powered Bin Lifter Operating Manual OM0016E/2 This manual contains important safety, installation and operating instructions for this unit. Read this manual

More information

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6

COMBAT SWIM BOARD. RJE International, Inc. RJE International Feb 1, TAC-300 Revision 6 COMBAT SWIM BOARD RJE International, Inc. YOUR SOURCE FOR DIVER NAVIGATION AND UNDERWATER RELOCATION EQUIPMENT RJE International Feb 1, 2017 12 TAC-300 Revision 6 RJE International, Inc. 15375 Barranca

More information

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644

Model C Pipe Line Strainer 6, 8 & 10 Inch (DN150, DN200 & DN250) 250 psi (17,2) General Description. Technical Data. Page of 6 MAY, 2006 TFP1644 Technical Services: Tel: (00) 31-9312 / Fax: (00) 791-5500 Model C Pipe Line Strainer 6, & 10 Inch (150, & 250) 250 psi (17,2) General Description The welded steel body Model C Pipe Line Strainers (Ref.

More information

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 MPS-1100 User Manual Mega Pool Saver Ltd PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 For further up to date instructions on how to install Mega Pool Saver MPS 1100, please

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions

UBEC 1AT. AUTO TANK Fill System Installation, Operation, & Setup Instructions Document Number: XE-ATA5PM-R1A UBEC 1AT AUTO TANK Fill System 08899155 Installation, Operation, & Setup Instructions Rev170906-EB-FRC PHYSICAL: 1302 WEST BEARDSLEY AVE ELKHART, IN 46514 WWW.ELKHARTBRASS.COM

More information

SPECIFICATIONS APCEPH1

SPECIFICATIONS APCEPH1 APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable 4.5 8.5 ph Weight < 1 lbs Dimensions 3" x

More information

MODEL CALIBRATION GAS DELIVERY SYSTEM

MODEL CALIBRATION GAS DELIVERY SYSTEM MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM APPLICABILITY & EFFECTIVITY This

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

THE UNIVENTOR 400 ANAESTHESIA UNIT

THE UNIVENTOR 400 ANAESTHESIA UNIT THE UNIVENTOR 400 ANAESTHESIA UNIT TABLE OF CONTENTS EDITION 3 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2 - INTRODUCTION 2.1. INTRODUCTION 3 Section

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information