Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision: 12/06
|
|
- Lily Harper
- 5 years ago
- Views:
Transcription
1 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe Revision: 12/06 Copyright Campbell Scientific, Inc.
2 Warranty and Assistance The CS512 OXYGUARD TYPE III DISSOLVED OXYGEN PROBE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and workmanship under normal use and service for twelve (12) months from date of shipment unless specified otherwise. Batteries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this warranty is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. The customer shall assume all costs of removing, reinstalling, and shipping defective products to CAMPBELL SCIENTIFIC, INC. CAMPBELL SCIENTIFIC, INC. will return such products by surface carrier prepaid. This warranty shall not apply to any CAMPBELL SCIENTIFIC, INC. products which have been subjected to modification, misuse, neglect, accidents of nature, or shipping damage. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability or fitness for a particular purpose. CAMPBELL SCIENTIFIC, INC. is not liable for special, indirect, incidental, or consequential damages. Products may not be returned without prior authorization. The following contact information is for US and International customers residing in countries served by Campbell Scientific, Inc. directly. Affiliate companies handle repairs for customers within their territories. Please visit to determine which Campbell Scientific company serves your country. To obtain a Returned Materials Authorization (RMA), contact CAMPBELL SCIENTIFIC, INC., phone (435) After an applications engineer determines the nature of the problem, an RMA number will be issued. Please write this number clearly on the outside of the shipping container. CAMPBELL SCIENTIFIC's shipping address is: CAMPBELL SCIENTIFIC, INC. RMA# 815 West 1800 North Logan, Utah CAMPBELL SCIENTIFIC, INC. does not accept collect calls.
3 CS512 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat bookmarks tab for links to specific sections. 1. General Information Specifications Optional Probe Accessories Optional Agitator Application Information Wiring Programming Calibration Maintenance Agitator Control...7 Appendix A. Dissolved Oxygen in Fresh Water Table... A-1 Figures Table 1-1. CS Preventing Bio-fouling of the CS CS512 with PT4 Agitator Agitator Wiring Sensor Wiring...4 i
4 CS512 Table of Contents Examples 1. Sample Program using P Sample Program using P Sample Program using VoltSE Sample Program using VoltDiff Sample Program using VoltSE Sample Program using P Sample Program using Expression Sample Program using P86 and P22 Instructions Sample Program using Portset Sample Program using Portset... 8 ii
5 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe An accurate and reliable sensor is a critical element in any measurement system. The Oxyguard Stationary Probe meets these criteria for the measurement of dissolved oxygen. 1. General Information The Oxyguard Stationary Probe is a galvanic probe which produces a millivolt signal proportional to the amount of oxygen present in the measured medium. Oxygen diffuses through the membrane onto the cathode, reacts chemically, and combines with the anode. An electrical current is produced by this chemical reaction which is converted from microamps to millivolts by an in-line resistor. An in-line thermistor also conditions the signal providing automatic temperature compensation. With these features, the probe produces a millivolt output proportional to the oxygen present in the medium in which it is placed. The probe consists of two parts, an upper part with cathode, anode and cable, and a lower part comprising a screw on membrane cap with fitted membrane. The cap is filled with electrolyte and simply screwed onto the top component. The probe is self-polarizing and requires no external power source. There are two wires to connect. Because the probe's output is linear, it is possible to connect it directly to a data acquisition system capable of handling the small millivolt signal. The probe's robust construction and simple design make maintenance and servicing it straightforward. There is no need to send the probe back to the factory for servicing. It utilizes a strong, easy-to-clean and easy-to-change membrane in a screw-on membrane cap. Regular servicing is not required. When necessary the probe can be fully overhauled in five minutes. FIGURE 1-1. CS512 1
6 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 2. Specifications Principle of Measurement: Membrane covered galvanic oxygen probe Output Signal: 2.5 to 5 mv per mg 1-1 Repeatability: Output Impedance: Response Time: Materials of Construction: Probe body: O-rings: Membrane: Dimensions and Weight: Cable: Operating Conditions: Temperature Pressure: Minimum Submersion Depth: Minimum Water Flow: Calibration: Temperature Compensation: Range of Dissolved Oxygen: Ships with: Better than ±0.2 mg/l calibration temperature equals measuring temperature ±5 C 1 kohm After equilibration, 1 minute for 95% of final value Delrin Membrane O-ring = Buna N Body Seal O-ring = Viton 0.05 mm (2 mil) Teflon 2.28 diameter x 2.3 height 15.9 oz. standard length 7 m (23 ft); other lengths available upon request 2-wire 22 awg shielded, PVC jacketed 0 to 40 C (32 to 122 F) 0 to 29 psig 60 mm (2 ½ in) 1 cm/s (.39 in/sec) across membrane In air or in air saturated water Automatic from 4-40 C ( F) 0-20 mg/l, 0-200% Sat 5 spare membranes with O-rings 50 ml electrolyte cathode cleaning pad 2
7 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 3. Optional Probe Accessories 4. Optional Agitator PT4-L Agitator for stagnant conditions DO electrolyte, 1 liter Membrane kit, 10 membranes The PT4 Agitator is a reliable and robust agitator for use in conjunction with probes subjected to bio-fouling in ponds and stagnant water conditions. O 2 probes require a minimum water velocity across their membranes to function properly. Therefore, to measure DO in stagnant water conditions, it is necessary to move the water past the membrane to get accurate and reliable DO measurements. In many instances the water also has a high bio-loading and the probes become fouled resulting in inaccurate DO measurements. FIGURE 4-1. Preventing Bio-fouling of the CS512 The PT4 Agitator overcomes these problems. The device is designed so that a soft bristle brush sweeps across the probe membrane or sensor tip. This sweeping action of the brush provides the required water velocity as well as prevents the membrane from becoming bio-fouled. The optimum sweeping frequency depends upon the design of probe and type of membrane used and water conditions. An ON-time of 0.25 seconds and OFF-time of 5 seconds is suitable in most circumstances. Agitator s overall size: 7-1/8" x 3-1/4" diameter, 1-1/4 lb. (180mm x 83mm, 0.6 kg) Supplied with 10 ft. (3 meters) cable. Power required: 10.5 to 18 VDC at the agitator, 1.1 amps. Maximum ON-time is 3 seconds. 3
8 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe FIGURE 4-2. CS512 with PT4 Agitator 5. Application Information Optional Repeat Cycle Timer for Agitators: Reciprocating action may be controlled by the optional solid state Repeat Cycle Timer. It sends 12 VDC pulses to the agitator coil. The ON-time is 0.25 sec. The OFF-time is adjustable from 3 to 12 sec.; requires supply voltage 10 to 17 VDC; housed in watertight cylinder 6.6" x 2" diameter (170 mm X 50 mm). NOTE SCWin users: This manual was written primarily for those whose needs are not met by SCWin. Your procedure is much simpler: just add the CS512 probe (it s in the water folder), save your program, and follow the wiring shown in Step 2 of SCWIN. 6. Wiring The CS512 probe can use one differential channel or one single-ended channel. Differential wiring is better at rejecting electrical noise and ground loop error. Colo r Whit e Functio n Signal + TABLE 6-1. Sensor Wiring CR510, CR10X, CR800, CR850, CR23X, CR1000, CR3000 Differential High, or Single-Ended Channel CR200 Series Single-Ended Channel Blue Signal - Differential Low or AG Ground 4
9 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 7. Programming In the CR510, CR10X, and CR23X datalogger, Instruction P1 or P2 can be used. Example 1 uses a single-ended measurement for the CS512 probe; example 2 uses a differential measurement. The example measurement instructions that follow do not store data to final storage. Additional instructions (typically P92, P77, and output processing instructions such as P70) are required to store data permanently. EXAMPLE 1. Sample Program using P1 1: Volt (SE) (P1) 1: 1 Reps 2: mv 60 Hz Rejection Range ; code 23 used for CR23X 3: 1 SE Channel 4: 1 Loc [ DOmV ] 5: 1.0 Multiplier *See Calibration* 6: 0.0 Offset EXAMPLE 2. Sample Program using P2 1: Volt (Diff) (P2) 1: 1 Reps 2: mv 60 Hz Rejection Range ; code 23 used for CR23X 3: 1 DIFF Channel 4: 1 Loc [ DOmV ] 5: 1.0 Multiplier *See Calibration* 6: 0.0 Offset In the CR1000, CR800, CR850, and CR3000 dataloggers, instruction VoltDiff or VoltSE is used to measure the CS512 probe. EXAMPLE 3. Sample Program using VoltSE VoltSE (DOmV,1,mV250,1,1,0,_60Hz,1.0,0) EXAMPLE 4. Sample Program using VoltDiff VoltDiff (DOmV,1,mV250,1,True,0,_60Hz,1.0,0) VoltSE (DOmV,1,1,1.0,0) In the CR200 series dataloggers, only the instruction VoltSE is used to measure the CS512 probe. EXAMPLE 5. Sample Program using VoltSE. 5
10 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 8. Calibration The multiplier is used to calibrate the CS512 probe. To calculate the multiplier: 1) Program the datalogger using a multiplier of one. 2) Place the OxyGuard probe in the air, shaded from the sun. Wait for readings to stabilize. This may take 15 minutes or more. 3) Determine the air temperature and barometric pressure. 4) Using a calibration chart such as that provided in the probe s manual, determine the oxygen concentration of the air. 5) Use the following equation to calculate the multiplier: M = P/R M = Multiplier P = Concentration in PPM of the air (from the calibration chart in Appendix A) R = The signal output of the OxyGuard probe when using a multiplier of one 6) Change the multiplier in the datalogger program from one to the calculated number. A more common way to enter the multiplier is to insert a separate instruction in the program. This will allow a new multiplier to be added to the program without rewriting, compiling, and downloading the program to the data logger. In the CR510, CR10X, and CR23X, use Instruction P36. The multiplier is entered into an input location called DOmult using the numeric display in PC200W, PC208W, LoggerNet, PC400, PConnect, PConnectCE, or the CR10KD. 57: Z=X*Y (P36) 1: 1 X Loc [ DOmV ] 2: 2 Y Loc [ DOmult ] 3: 3 Z Loc [ DOppm ] DOppm = DOMult * DOmV EXAMPLE 6. Sample Program using P36 In all dataloggers that use CRBasic, an expression is written. The multiplier value is entered into the expression through the Public Table using the numeric display in PC200W, LoggerNet, PC400, PConnect, and PConnectCE. EXAMPLE 7. Sample Program using Expression 6
11 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 9. Maintenance The CS512 probe needs little maintenance. Regular cleaning of the membrane is all that is required. The membrane is very durable and can be cleaned with a cloth or soft paper. Do not scratch it clean with your fingernail. 10. Agitator Control In low flow conditions (less than about 5 cm/sec), it may be necessary to add an agitator to the CS512 probe. Campbell Scientific ships the agitator with a repeat cycle timer. Using the repeat cycle timer requires no datalogger programming. However, some users choose to use a solid state relay and have the datalogger agitate the water on the probe face either periodically throughout the day or just before measurement. Agitating just before the measurement saves on power and causes less wear and tear on the agitator and probe membrane. The wiring for the agitator as controlled by this example program would be as follows: Ground/G Datalogger 4 1 #7321 Relay Crydom D1D07 BLACK Agitator Port C1 3 2 WHITE V Battery FIGURE Agitator Wiring The following instructions would trigger the agitator as discussed in the agitator manual. In the CR510, CR10X, and CR23X, use instruction P86 and P22. 7
12 Campbell Scientific CS512 Oxyguard Type III Dissolved Oxygen Probe 45: Do (P86) 1: 41 Set Port 1 High EXAMPLE 8. Sample Program using P86 and P22 Instructions 46: Excitation with Delay (P22) 1: 1 Ex Channel 2: 20 Delay W/Ex (units = 0.01 sec) 3: 0 Delay After Ex (units = 0.01 sec) 4: 0 mv Excitation 47: Do (P86) 1: 51 Set Port 1 Low 48: End (P95) Portset (1,1) Delay(500,msec) Portset(1,0) Portset (1,1) Delay (1,500,msec) Portset (1,0) In the CR200 series dataloggers, use the Portset instruction. EXAMPLE 9. Sample Program using Portset In the CR1000, CR800, CR850, and CR3000 dataloggers, use the Portset instruction. EXAMPLE 10. Sample Program using Portset The above example is not as power efficient as possible and would require AC power to maintain a sufficient battery charge. If it is necessary to operate an agitator without AC power available, write the program so that the agitator is only operated for a short period of time just before the measurement is to be taken. 8
13 Appendix A. Dissolved Oxygen in Fresh Water Table A-1
14 Appendix A. Dissolved Oxygen in Fresh Water Table A-2
15 This is a blank page.
16 Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah UNITED STATES Campbell Scientific Africa Pty. Ltd. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA Campbell Scientific Australia Pty. Ltd. (CSA) PO Box 444 Thuringowa Central QLD 4812 AUSTRALIA Campbell Scientific do Brazil Ltda. (CSB) Rua Luisa Crapsi Orsi, 15 Butantã CEP: São Paulo SP BRAZIL Campbell Scientific Canada Corp. (CSC) th Street NW Edmonton, Alberta T5M 1W7 CANADA Campbell Scientific Ltd. (CSL) Campbell Park 80 Hathern Road Shepshed, Loughborough LE12 9GX UNITED KINGDOM Campbell Scientific Ltd. (France) Miniparc du Verger - Bat. H 1, rue de Terre Neuve - Les Ulis COURTABOEUF CEDEX FRANCE campbell.scientific@wanadoo.fr Campbell Scientific Spain, S. L. Psg. Font 14, local Barcelona SPAIN info@campbellsci.es Please visit to obtain contact information for your local US or International representative.
Campbell Scientific CS511-L Sensorex Dissolved Oxygen Probe Revision: 6/12
Campbell Scientific CS511-L Sensorex Dissolved Oxygen Probe Revision: 6/12 Copyright 2001-2012 Campbell Scientific, Inc. Warranty PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell
More informationINSTRUCTION MANUAL. CS115 Barometric Pressure Sensor 3/03. Copyright (c) Campbell Scientific, Inc.
INSTRUCTION MANUAL CS115 Barometric Pressure Sensor 3/03 Copyright (c) 2002-2003 Campbell Scientific, Inc. Warranty and Assistance The CS115 BAROMETRIC PRESSURE SENSOR is warranted by CAMPBELL SCIENTIFIC,
More informationINSTRUCTION MANUAL. Using the CS400/CS405 (KPSI Series 169/173) Submersible Pressure Transducer with Campbell Scientific Dataloggers.
INSTRUCTION MANUAL Using the CS400/CS405 (KPSI Series 169/173) Submersible Pressure Transducer with Campbell Scientific Dataloggers Revision: 11/02 Copyright (c) 2000-2002 Campbell Scientific, Inc. The
More informationCS431 Submersible Pressure Transducer Revision: 3/09
CS431 Submersible Pressure Transducer Revision: 3/09 Copyright 2008-2009 Campbell Scientific, Inc. Warranty and Assistance The CS431 SUBMERSIBLE PRESSURE TRANSDUCER is warranted by CAMPBELL SCIENTIFIC,
More informationPWC100 Present Weather Sensor Calibrator Revision: 3/12
PWC100 Present Weather Sensor Calibrator Revision: 3/12 Copyright 2008-2012 Campbell Scientific, Inc. PLEASE READ FIRST About this manual Please note that this manual was originally produced by Campbell
More informationCS511. Dissolved Oxygen Sensor. Revision: 5/18 Copyright Campbell Scientific, Inc.
CS511 Dissolved Oxygen Sensor Revision: 5/18 Copyright 2001 2018 Campbell Scientific, Inc. Guarantee This equipment is guaranteed against defects in materials and workmanship. We will repair or replace
More informationCSBUOY-DT INSTRUCTION MANUAL
CSBUOY-DT INSTRUCTION MANUAL 5/02 COPYRIGHT (c) 2002 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC (CANADA) CORP. ( CSC ) to
More informationPWC100 Present Weather Sensor Calibrator
PWC100 Present Weather Sensor Calibrator User Guide Issued 6.2.12 Copyright 2008-2012 Campbell Scientific Ltd. CSL 801 Guarantee This equipment is guaranteed against defects in materials and workmanship.
More informationTGA200 Trace Gas Analyzer Overview 9/11
TGA200 Trace Gas Analyzer Overview 9/11 C o p y r i g h t 2 0 1 1 C a m p b e l l S c i e n t i f i c, I n c. Warranty PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific,
More informationCS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL
CS115 BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL 3/03 COPYRIGHT (c) 2002-2003 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC
More informationUser's Manual. Heavy Duty Dissolved Oxygen Meter. Model
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
More informationUSING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL
USING THE CS400/CS405 (KPSI SERIES 169/173) SUBMERSIBLE PRESSURE TRANSDUCER WITH CAMPBELL SCIENTIFIC DATALOGGERS INSTRUCTION MANUAL REVISION: 11/02 COPYRIGHT (c) 2000-2002 CAMPBELL SCIENTIFIC, INC. This
More information52202/52203 Tipping Bucket Raingauge
52202/52203 Tipping Bucket Raingauge User Manual Issued 30.11.10 Copyright 1998-2010 Campbell Scientific Ltd. CSL 382 Guarantee This equipment is guaranteed against defects in materials and workmanship.
More informationINSTRUCTION MANUAL. 840 Transmitter. Loop Powered Dissolved Oxygen Transmitter
INSTRUCTION MANUAL Loop Powered Dissolved Oxygen Transmitter Contents Contents...2 Introduction...3 Range and Display Settings...4 Installation...5 Electrical Installation...6 Calibration...7 EasyCal...8
More informationCS470/CS471 Compact Bubbler System Revision: 7/11
CS470/CS471 Compact Bubbler System Revision: 7/11 Copyright 2009-2011 Campbell Scientific, Inc. Warranty and Assistance PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific,
More informationMini-Pro CO2 Sensor User s Manual - ANALOG MODEL -
Mini-Pro CO2 Sensor User s Manual - ANALOG MODEL - Table of Contents 1. Introduction 3 2. Instrument Setup 4 2.1 Instrument Checklist 4 2.2 Optional Accessories 4 2.3 Gas Concentration Ranges Available
More informationInstruction Manual HI Portable Waterproof Dissolved Oxygen Meter.
Instruction Manual HI 9142 Portable Waterproof Dissolved Oxygen Meter www.hannainst.com 1 Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully
More informationInstruction Manual HI Portable Dissolved Oxygen Meter. DO meter HI 8043 STB C OFF O 2 ZERO SLOPE C. ins rum n s
Instruction Manual HI 8043 Portable Dissolved Oxygen Meter DO meter HI 8043 ZERO SLOPE C ins rum n s This Instrument is in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna
More informationAqua-DP. Aqua-DP Waterproof Dissolved Oxygen - ph -mv Temperature Meter. TPS Australia - Quality hand-made instruments since 1968.
TPS Australia - Quality hand-made instruments since 1968. Waterproof Dissolved Oxygen - ph -mv Temperature Meter Dual readout of Dissolved Oxygen and ph/mv Waterproof to IP65 Easy to use One-touch calibration
More informationThe Oxygen Sensor can be connected to all types of einstein Tablets, einstein LabMate, and einstein LabMate +.
The Oxygen sensor is a maintenance- free galvanic oxygen electrode capable of measuring Oxygen in solutions. With built-in temperature compensation, this sensor provides an easy way for students to receive
More information12mm Dissolved Oxygen Sensor Care and Use Instructions
12mm Dissolved Oxygen Sensor Care and Use Instructions How Dissolved Oxygen Sensors Work Your Dissolved Oxygen (DO) Probe is a galvanic electrochemistry device; i.e. it does not require power from your
More information210 Series Transmitter with External Electrochemical Sensor
210 Series Transmitter with External Electrochemical Sensor INSTRUCTIONS Installation and Operation of the AMC-210 Series Transmitter with External Electrochemical Sensor IMPORTANT: Please read these installation
More informationUnisense In Situ UniAmp Connector System
Unisense In Situ UniAmp Connector System Overview The Unisense In Situ UniAmp Connector system is designed for easy replacement of sensors. Unisense In Situ UniAmp Connector system is a dedicated system
More informationDeep Submersible Level Transducer Series 300DS
KPSI Transducers Deep Submersible Level Transducer Series 300DS FEATURES! Custom Level Ranges up to 4614 ft (1408 m) H 2 O! Accuracy of ±0.5% FS! Analog Outputs of 4-20 ma or 0-5 VDC! Welded 316 SS Construction!
More informationSTERILIZABLE DISSOLVED OXYGEN SENSORS
STERILIZABLE DISSOLVED OXYGEN SENSORS USER MANUAL Table of Contents 1. Introduction 2. Operation 3. Calibration 4. Electrode Verification 5. Mounting 6. Maintenance 7. Storage 8. Instructions for Exchange
More informationUSER MANUAL. CS106 Barometric Pressure Sensor. Issued:
USER MANUAL CS106 Barometric Pressure Sensor Issued: 12.12.17 Copyright 1995-2017 Campbell Scientific, Inc. Printed under licence by Campbell Scientific Ltd. CSL 713 Guarantee This equipment is guaranteed
More informationOxymax H COS21. Technical Information. Sensor with long-term stability for frequent sterilization and autoclaving
Technical Information Oxymax H COS21 Sensor with long-term stability for frequent sterilization and autoclaving Application Process control in enzyme production Control of culture growth Biotechnological
More informationOxymax W COS41. Technical Information. Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications
Technical Information Oxymax W COS41 Potentiostatic amperometric two-electrode sensor Long-term stable sensor for water and wastewater applications Application The continuous measurement of the dissolved
More informationD-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA
D-Opto Dissolved Oxygen Sensor Operation Manual for the D-Opto 4-20mA Software version 2.6 Table of contents 1 Introduction...3 1.1 Optical Sensor Technology...3 1.2 Installation...4 1.3 Operation...5
More informationOxygen Sensor with Electrode
imagine explore learn Oxygen Sensor with Electrode Product Number: ENOXY-A222 Overview The Oxygen sensor is a maintenance-free galvanic oxygen electrode, capable of measuring Oxygen both in the air and
More informationINSTRUCTION MANUAL. CS106 Barometric Pressure Sensor Revision: 4/17. Copyright Campbell Scientific, Inc.
INSTRUCTION MANUAL CS106 Barometric Pressure Sensor Revision: 4/17 Copyright 1995-2 017 Campbell Scientific, Inc. Assistance Products may not be returned without prior authorization. The following contact
More informationSS32L Dissolved O 2 Probe
BIOPAC WWW.biopac.com Systems, Inc. Application Note PH-185 SS32L Dissolved O 2 Probe SS32L Dissolved O 2 Probe BIOPAC Software SS32L Specifications BSL PRO v. 3.6.6 BIOPAC Hardware SS32L Dissolved O 2
More informationBI-680 Online Dissolved Oxygen Controller Instruction Manual
BI-680 Online Dissolved Oxygen Controller Instruction Manual BANTE INSTRUMENTS CO., LTD BI-680 Online Dissolved Oxygen Controller 1 Introduction Thank you for selecting the BI-680 online dissolved oxygen
More informationINSTRUCTION MANUAL. CS106 Barometric Pressure Sensor Revision: 4/17. Copyright Campbell Scientific, Inc.
INSTRUCTION MANUAL CS106 Barometric Pressure Sensor Revision: 4/17 Copyright 1995-2 017 Campbell Scientific, Inc. Limited Warranty The CS106 Barometric Pressure Sensor is warranted for three (3) years
More informationT EK-SUB 4800C 19 mm Submersible Level Transmitter
Technology Solutions T EK-SUB 4800C 19 mm Submersible Level Transmitter Instruction Manual Document Number: IM-4800C www.tek-trol.com Table of Contents 1 Safety Instructions... 2 1.1 Intended Use... 2
More informationDissolved Oxygen Sensor
Instruction Manual 499ADO and 499ADO-VP LIQ_MAN_ABR_499ADO May 2014 Dissolved Oxygen Sensor CAUTION For additional information, please visit our website at www.rosemountanalytical.com SENSOR/PROCESS APPLICATION
More informationUSER MANUAL. CRS451/CRS456 Submersible Water-Level Recording Sensor. Issued:
USER MANUAL CRS451/CRS456 Submersible Water-Level Recording Sensor Issued: 3.11.15 Copyright 2013-2015 Campbell Scientific, Inc. Printed under licence by Campbell Scientific Ltd. CSL 996 Guarantee This
More informationIntelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter
Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)
More informationNEULOG OXYGEN LOGGER SENSOR GUIDE
NeuLog oxygen logger sensor NUL-205 The oxygen sensor can be used for any science experiment or activity where oxygen levels, dissolved or gaseous, are required. Some fields of study include Chemistry,
More informationDMM600 DUFF MOISTURE METER INSTRUCTION MANUAL
DMM600 DUFF MOISTURE METER INSTRUCTION MANUAL 5/02 COPYRIGHT (c) 2002 CAMPBELL SCIENTIFIC, INC. This is a blank page. WARRANTY AND ASSISTANCE This equipment is warranted by CAMPBELL SCIENTIFIC (CANADA)
More informationBante810 Benchtop Dissolved Oxygen Meter Instruction Manual
Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante810 Benchtop Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante810 benchtop dissolved oxygen
More informationASIC-Based Small Bore Submersible Level Transducer
ASIC-Based Small Bore Submersible Level Transducer KPSI Transducers Series 340 FEATURES Custom Level Ranges up to 230 ft (70 m) H 2 O Unparalleled Performance - Static Accuracy: ±0.05% FS - Total Error
More informationSPECIFICATIONS APCEPH1
APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable 4.5 8.5 ph Weight < 1 lbs Dimensions 3" x
More informationHLM-2000-TX Gas Transmitter User Manual
HLM-2000-TX Gas Transmitter User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay Engineering Ltd. Oakville,
More informationD-OptoLogger Dissolved Oxygen Logger Operation Manual
D-OptoLogger Dissolved Oxygen Logger Operation Manual Software version 3.4 Contents 1. Introduction..... 1 Optical Sensor Technology.....1 Features...... 1 2. D-OptoLogger Specifications.2 Specifications...
More informationD-Opto Dissolved Oxygen Sensor Operation Manual
D-Opto Dissolved Oxygen Sensor Operation Manual Software version 2.6 Contents 1. Introduction..... 1 Optical Sensor Technology.... 1 Features...... 1 2. D-Opto Specifications. 2 Specifications... 2 3.
More informationHeavy Duty Dissolved Oxygen Meter
User's Manual Heavy Duty Dissolved Oxygen Meter Model 407510 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 FAX 781.665.0780 - TestEquipmentDepot.com Introduction Congratulations
More informationOptical Dissolved Oxygen Meter
Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital, weighted probe No membranes No electrolytes No oxygen consumption No flow dependence
More informationOxymax W COS51D. Technical Information. Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor
Technical Information Oxymax W COS51D Digital sensor for measuring dissolved oxygen Membrane-covered amperometric sensor Application The continuous measurement of the concentration of dissolved oxygen
More informationHI 9143, HI 9143M HI 9145
SAMPLE Instruction Manual HI 9143, HI 9143M HI 9145 Portable Waterproof Microprocessor Dissolved Oxygen Meters ppm C HI 9143 Microprocessor Auto Cal Dissolved Oxygen Meter ON/OFF CAL RANGE HOLD FACTOR
More informationBante820 Portable Dissolved Oxygen Meter Instruction Manual
Bante820 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante820 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante820 portable dissolved oxygen
More informationTD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual
Relied on Worldwide in the Most Extreme Conditions TD-106-5D TD-106-5D-A Wind Direction Sensor User s Manual Texas Electronics, Inc. Dallas, TX 75237 Fax.214.631.4218 4230 Shilling Way Tel.214-631-2490
More informationDPC-30 DPC-100. Reference Manual
DPC-30 DPC-100 Reference Manual 1. Introduction 1.1 Description The Martel DPC Digital Pneumatic Calibrator improves upon traditional dial gauge pneumatic calibrators. The Martel DPC improves accuracy,
More informationDISSOLVED OXYGEN SENSOR BT34i
DISSOLVED OXYGEN SENSOR BT34i USER S GUIDE CENTRE FOR MICROCOMPUTER APPLICATIONS http://www.cma-science.nl Short description The CMA Dissolved Oxygen (DO) sensor BT34i measures the concentration of dissolved
More informationD-Opto. Dissolved Oxygen Sensor. Operation Manual (Software Version 1.0)
D-Opto Dissolved Oxygen Sensor Operation Manual (Software Version 1.0) Table of contents 1 Introduction...3 1.1 Optical Sensor Technology...3 2 Software...4 2.1 Installation...4 2.2 Operation...4 3 Operation...9
More informationURC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports
URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT 2013 Universal Remote Control, Inc. The information in this Owner s Manual is copyright protected.
More informationMODEL CALIBRATION GAS DELIVERY SYSTEM
MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM Sierra Monitor Corporation 1991 Tarob Court, Milpitas, CA 95035 (408) 262-6611 MODEL 1200-26 CALIBRATION GAS DELIVERY SYSTEM APPLICABILITY & EFFECTIVITY This
More informationFTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL
FTS SUBMERSIBLE PRESSURE TRANSMITTER USER S MANUAL TABLE OF CONTENTS PRODUCT OVERVIEW 2 I - USE AND CARE: 3 II - INSTALLATION: 5 III - GENERAL MAINTENANCE TIPS: 5 IV - APPENDIX: A-1 2-WIRE CURRENT LOOP
More informationMODEL GT820 OXYGEN SENSOR
INSTRUCTION MANUAL MODEL GT820 OXYGEN SENSOR 70046 The information and technical data disclosed by this document may be used and disseminated only for the purposes and to the extent specifically authorized
More informationTV-114 TV-114-A Wind Speed Sensor User s Manual
Relied on Worldwide in the Most Extreme Conditions TV-114 TV-114-A Wind Speed Sensor User s Manual Texas Electronics, Inc. Dallas, TX 75237 Fax.214.631.4218 4230 Shilling Way Tel.214-631-2490 www.texaselectronics.com
More informationGas Pressure Probe. Information Sheet. Total Dissolved Gas
Total Dissolved Gas Information Sheet T900 Total Dissolved Gas Pressure Probe Description The In-Situ Inc. T900 probe is a specially adapted submersible pressure transducer designed to monitor Total Dissolved
More informationModel B Wire Wet Oxidant Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park
Model B12-69 2-Wire Wet Oxidant Gas Transmitter Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph
More informationAdvanced Test Equipment Rentals ATEC (2832)
WARRANTY CLAUSE METROSONICS warrants each new cl-304 manufactured and sold to be free from defects in material, workmanship and construction, except for batteries which may be contained therein, and that
More informationHLM-2000-TX Gas Transmitter User Manual
HLM-2000-TX Gas Transmitter User Manual Technical Support Continental North America Toll Free 1-(800) 387-9487 Ph: +1 (905) 829-2418 Fx: +1 (905) 829-4701 A Product of Arjay Engineering Ltd. Oakville,
More informationBante821 Portable Dissolved Oxygen Meter Instruction Manual
Bante821 Portable Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante821 Portable Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante821 portable dissolved oxygen
More informationOxygen Measurement Systems High Reliability and Wide Application Coverage
Introduction High Process Efficiency Under Any Condition Oxygen Measurement Systems High Reliability and Wide Application Coverage METTLER TOLEDO provides sensors to measure dissolved oxygen (DO) in demanding
More informationColumbus Instruments
0215-003M Portable O 2 /CO 2 /CH 4 Meter User s Manual Columbus Instruments 950 NORTH HAGUE AVENUE TEL:(614) 276-0861 COLUMBUS, OHIO 43204, USA FAX:(614) 276-0529 1 www.colinst.com TOLL FREE 1-800-669-5011
More informationQuick Start Guide LIQ-QSG-499AOZ, Rev M July Rosemount 499AOZ. Dissolved Ozone Sensor
Quick Start Guide LIQ-QSG-499AOZ, Rev M July 2017 Rosemount 499AOZ Dissolved Ozone Sensor Safety information CAUTION! SENSOR/PROCESS APPLICATION COMPATIBILITY The wetted sensor material may not be compatible
More informationCalibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.
Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up
More informationDOscan10 Pocket Dissolved Oxygen Tester Instruction Manual
DOscan10 Pocket Dissolved Oxygen Tester Instruction Manual BANTE INSTRUMENTS CO., LTD DOscan10 Pocket Dissolved Oxygen Tester 1 Thank you for selecting the DOscan10 pocket dissolved oxygen tester. This
More informationPRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)
Instruction Sheet for the PASCO Model CI-6532A PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa) 012-06859B 10/98 $1.00 polyurethane tubing syringe cable with DIN s to computer interface quick release s (4) pressure
More informationHigh-performance submersible pressure transmitter For level measurement Model LH-10
Electronic pressure measurement High-performance submersible pressure transmitter For level measurement Model LH-10 WIKA data sheet PE 81.09 Applications Level measurement in rivers and lakes Deep well
More informationIn Vivo Scientific, LLC INSTRUCTION MANUAL
CO 2 Controller In Vivo Scientific, LLC INSTRUCTION MANUAL CONTENTS CONTENTS...1 ABOUT THIS MANUAL...2 INTRODUCTION...2 Cautions and Warnings...2 Parts List...2 Unpacking...2 INSTRUMENT DESCRIPTION...3
More informationLUDLUM MODEL 239-1F FLOOR MONITOR. Revised December 2010
LUDLUM MODEL 239-1F FLOOR MONITOR Revised LUDLUM MEASUREMENTS, INC. 501 OAK ST., P.O. BOX 810 SWEETWATER, TX 79556 325/235-5494 FAX: 325/235-4672 STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants
More informationCSA Sample Draw Aspirator Adapter Operator s Manual
30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating
More informationOxyScan Graphic. Operating Instructions. UMS Micro-oxygen sensor 501. Microprocessor instrument
OxyScan Graphic Operating Instructions UMS Micro-oxygen sensor 501 Microprocessor instrument Introduction Thank you for choosing the UMS Micro Oxygen Sensor 501 - a highly advanced product! Please read
More informationResearch Grade Blood Pressure Transducer User's Manual
Research Grade Blood Pressure Transducer User's Manual Research Grade Blood Pressure Transducer, 110 VAC/60 Hz MA1 60-3002 Research Grade Blood Pressure Transducer, 220 VAC/50 Hz MA1 60-3003 WEEE/RoHS
More informationDissolved Oxygen Guide
Educat i onser i es Di ssol vedoxygengui de Dissolved Oxygen Guide Introduction Dissolved oxygen probes provide a convenient approach to essentially direct measurement of molecular oxygen. The membrane
More information_ pressure transducers. User Manual
_ pressure transducers User Manual summary introduction DescriPTION preliminary checks Installation taking measurements data management Troubleshooting maintenance Appendix 1 Page 4 Page 5 Page 6 Page
More informationOptical Dissolved Oxygen Meter
Optical Dissolved Oxygen Meter HI764113 Rugged Optical Dissolved Oxygen Probe for Fresh and Saltwater Applications Digital probe Fast and stable readings No membranes Not affected by sunlight No electrolytes
More informationSTEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE
STEAM STERILIZABLE POLAROGRAPHIC OXYGEN ELECTRODE GENERAL INFORMATION This family of dissolved oxygen electrodes is of the steam sterilizable polarographic type, designed to be interchangeable with NBS
More informationRGC-IR Remote Gas Calibrator for IR400
Remote Gas Calibrator for IR400 The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by
More informationInstruction Sheet. Important Note: Information that requires special emphasis. Note: Information that supplements points in the main text.
Hach LDO Sensor Instruction Sheet 00745589 Safety Precautions Please read this entire instruction sheet before operating this sensor. Pay particular attention to all danger and caution statements. Failure
More informationGG-VL2-NH3 AMMONIA VENT LINE SENSOR. Installation and Operation Manual
GG-VL2-NH3 AMMONIA VENT LINE SENSOR Installation and Operation Manual 2 GG-VL2-NH3 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified
More informationVinmetrica Dissolved Oxygen System User Manual
Vinmetrica Dissolved Oxygen System User Manual The Vinmetrica dissolved Oxygen system provides a simple, accurate and affordable way to determine oxygen concentrations in wine and other samples. Materials
More informationE X R A D I N Spherical Ion Chambers A3. A4 REF DOC #
E X R A D I N Spherical Ion Chambers A3. A4 REF 92717. 92715 R DOC #80360-00 E X R A D I N Spherical Ion Chambers A3. A4 REF 92717. 92715 STANDARD IMAGING INC. 7601 Murphy Drive Middleton, WI 53562 TEL
More informationASDX Series Silicon Pressure Sensors
ASDX Series Silicon Pressure Sensors DESCRIPTION The ASDX Series is a Silicon Pressure Sensor offering a ratiometric analog interface for reading pressure over the specified full scale pressure span and
More informationDEEPSEA POWER & LIGHT. Operator s Manual. SeaLite Six. Original Instruction Ruffin Road San Diego, CA USA
SeaLite Six DEEPSEA POWER & LIGHT Record product serial number below as it appears on the nameplate. Serial # Pin-out Postive = Pin Negative = Pin Ground = Pin Dimming (if applicable) = Pin T: (858) 576-1261
More informationPortable Gas Monitor GX User Maintenance Manual (H4-0050)
H4E-0050 Portable Gas Monitor GX-8000 User Maintenance Manual (H4-0050) Need of Maintenance and Servicing This gas monitor must be maintained in a normal state at all times to prevent accidents due to
More informationOxymax H COS21D. Technical Information
Technical Information Digital sensor for measuring dissolved oxygen Sensor with long-term stability for frequent sterilization and autoclaving Application Process control in enzyme production Control of
More informationRK LEL Sample Draw Aspirator Adapter Operator s Manual
30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment
More informationLDO II AQ 2/2014, Edition 1.5
9623800 LDO II AQ 2/2014, Edition 1.5 USER MANUAL Table of Contents Specifications on page 2 General information on page 3 Product overview on page 4 Installation on page 5 Operation on page 7 Maintenance
More informationDeltaSpan Pressure Transmitters LD10 Series Owner s Manual
Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 10500 Humbolt Street Los Alamitos, CA 90720. If
More informationExpert Hydrostatic Level Transmitters
Expert Hydrostatic s General Features MJK Expert hydrostatic level transmitters are designed for level measurement by submerging the transmitter in open channels, drains and tanks. Expert hydrostatic level
More informationINSTRUCTION MANUAL. CRS451/CRS456 Submersible Water-Level Recording Sensor Revision: 12/15. Copyright Campbell Scientific, Inc.
INSTRUCTION MANUAL CRS451/CRS456 Submersible Water-Level Recording Sensor Revision: 12/15 Copyright 2013-2015 Campbell Scientific, Inc. Limited Warranty Products manufactured by CSI are warranted by CSI
More informationOxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems
Oxygen Concentrator Installation and Operation Manual ClearWater Tech, LLC. Integrated Ozone Systems 850-E Capitolio Way, San Luis Obispo, Ca 93401 805-549-9724 Fax: 805-549-0306 E-mail: service@cwtozone.com
More informationBUYER S GUIDE AQUAlogger 530WTD
OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 530WTD Wireless Temperature and Depth Logger AQUAlogger 530WTD The AQUAlogger 530WTD has an innovative design that includes the ability to transfer stored
More information! Unique Cable Seal System! Fully Temperature Compensated! Datalogger Compatible
FEATURES! High Static Accuracy & Repeatability! Welded 316 SS or Titanium Construction! Small Rugged Package! User-Specified Pressure Ranges Available! 1% Computer-Tested, Calibrated and Serialized! Unique
More informationAerobic Respiration. Evaluation copy
Aerobic Respiration Computer 17 Aerobic cellular respiration is the process of converting the chemical energy of organic molecules into a form immediately usable by organisms. Glucose may be oxidized completely
More informationGASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL
GASGUARD VENT LINE3 Ammonia Sensor OPERATING & INSTALLATION MANUAL Operating and Installation Manual Warning Use this product only in the manner described in this manual. If the equipment is used in a
More information