E3G-L1/L3. Effectively Cuts the Influence of Workpiece Characteristics, Such as Gloss, Incline, and Color. Distance-setting Photoelectric Sensor

Size: px
Start display at page:

Download "E3G-L1/L3. Effectively Cuts the Influence of Workpiece Characteristics, Such as Gloss, Incline, and Color. Distance-setting Photoelectric Sensor"

Transcription

1 Distance-setting Photoelectric EG-L/L CSM_EG-L_L_DS_E Effectively Cuts the Influence of Workpiece Characteristics, Such as Gloss, Incline, and Color. Be sure to read Safety Precautions on page. Features A -mm-dia. Pin-point Beam Allows Detection of Minute Objects Smallest in the Industry EG-L OMR's unique Hyper LED achieves a pinpoint light source only /7 the size of conventional light sources, with uniform light-intensity distribution. The Hyper LED achieves stable detection of small objects by eliminating the dead band that results from the drop-out that commonly occurs at the center of conventional LEDs. The clearly visible spot makes it easy to check the optical axis adjustment and sensing position. Stable Detection Based Not Only on Object Color, But Also on and Glossiness The EG-L is. times more stable than previous models with inclination characteristics. The use of the shine-proof optical system with conventional triangulation reduces the discrepancies in sensing distance due to object color, surface, and inclination. (The EG-L is. times more stable than previous models.) Shine-proof Optical System (EG-L, EG-L) First in the Industry Previous Distancesetting Models OK Distance fluctuation detected due to slight lifting. NG (Lifting of IC) Intensity Light source LED PSD A low-error distance signal is assured because an image is formed on the photosensing device (PSD), irrespective of the sensing distance. Detection is also stable with respect to the inclination of the object. Error Center of gravity Intensity Light source LED PSD At some distances, images cannot be formed on the photosensing device (PSD). The spot diameter is large, distance errors occur due to displacement of the center of gravity, and detection is unstable with respect to the inclination of the object.

2 EG-L/L Simple Detection of Glossy, Uneven Objects Normal Mode Threshold (light) Conveyor (background) (dark) Triangulation with hysteresis of % or less (EG-L) is used, so objects beyond the set distance are not detected. At a set distance of mm, steps that are. mm high can be detected. Selectable IP7 Waterproofing CE Marking (dark) Threshold (light) Threshold First in the Industry Zone Mode Conveyor (background) (dark, when dark is set for ) Glossy, uneven objects are reliably detected because (light) status occurs only when the conveyor is detected, and (dark) status occurs when an object is present. The meets the European EMC Directive, allowing it to be mounted in export devices with confidence. Optimal and Conveyor Teaching. Double-bar Display Shows Excess Gain at a Glance. The features onetouch teaching settings. After the workpiece, background, and conveyor teaching are complete, fine adjustment of the sensitivity can be made in levels for Normal Mode or levels for Zone Mode. The excess gain in distance or detecting of small steps can be easily set. A Lineup of M8 Connectors Easy to disconnect, making maintenance simple. The operation indicator turns when the light incident level exceeds a certain threshold. Excess gain can also be checked at a glance. Straight L-shaped Meets the Needs of All Industries, Including Semiconductors, Electronic Components, Food, and Packaging Normal Mode EG-L (-mm Models) Detecting minute electronic components in a tray Detecting thin or uneven objects EG-L (-mm Models) Detecting objects on a production line with a glossy background IC No packaging Zone Mode EG-L (-mm Models) Detecting packaged candies Detecting tiles on a conveyor EG-L (-mm Models) Detecting packaged confectionery on a conveyor Glossy wrapping Glossy wrapping

3 Ordering Information s Appearance Connection method Sensing/Setting range Operation mode Red light EG-L/L Infrared light Model NPN output PNP output Pre-wired mm mm mm mm Min.setting Setting range: Max. setting to mm EG-L EG-L Connector (M8) Sensing range: to mm Light Dark EG-L EG-L Pre-wired mm mm mm mm (selectable) Setting range: Min.setting to mm for white EG-L EG-L Connector (M8) Sensing range: EG-L EG-L to mm for white Accessories (Order Separately) Mounting Brackets Max.setting Appearance Model Quantity Remarks E9-L9 Provided with the EG-L@/-L@ E9-L Provided with the EG-L@/-L@ I/O Connectors (M8) Cable specifications Appearance Cable type Model Straight m XSF-M--A Standard Cable m Four-wire XSF-M--A L-shaped m type XSF-M--A m XSF-M--A

4 Ratings and Specifications EG-L/L Item Sensing method Model Sensing range Setting range NPN output PNP output Distance-setting EG-L EG-L EG-L EG-L EG-L EG-L EG-L EG-L to mm ( mm white, setting distance: mm) to mm ( mm white, black ) to mm ( mm white, setting distance: mm) to mm ( mm black, setting distance: mm) to mm ( mm white ) to mm ( mm black ) Differential travel % max. of setting distance % max. of setting distance (typical) Reflectivity characteristics (black/white error) Light source (wavelength) % max. of setting distance Red LED (7 nm) % max. of setting distance (at to -mm setting distance) Infrared LED (8 nm) Spot size -mm dia. max. (at 8-mm sensing distance) -mm dia. max. (at -mm sensing distance) Power supply voltage to VDC including % (p-p) ripple Current consumption ma max. ma max. Control output Protection circuit Load power supply voltage: VDC max., Load current: ma max. (Residual voltage: NPN output:. V max., PNP output:. V max.) Open collector output (NPN/PNP, depends on the model) Light /Dark selectable Power supply reverse polarity protection, Load short-circuit protection, Mutual interference prevention Response time Operate or reset:. ms max. Operate or reset:. ms max. Distance setting Indications Ambient illumination (Receiver side) Ambient temperature Ambient humidity Insulation resistance Dielectric strength Vibration resistance (destruction) Shock resistance (destruction) Degree of protection Connection method Teaching (in NORMAL or ZE mode) Manual fine threshold adjustment (NORMAL mode: levels, ZE mode: levels) Operation indicator, Distance indicator (green: 8 levels), Threshold indicator (red, NORMAL mode: levels, ZE mode: levels) Incandescent lamp:, lx max., Sunlight:, lx max. Operating: C to C, Storage: C to 7 C (with no icing or condensation) Operating: % to 8%, Storage: % to 9% (with no condensation) MΩ min. at VDC, VAC, /Hz for min to Hz,.-mm double amplitude for hours each in X, Y, and Z directions m/s times each in X, Y, and Z directions IEC IP7 (with protective cover) Pre-wired (Standard length: m) Connector (M8) Pre-wired (Standard length: m) Connector (M8) Weight (packed state) Approx. g Approx. g Approx. g Approx. g Case PBT (polybutylene terephthalate) Fine distance adjustment Cover Accessories Mounting Bracket Methacrylic resin Stainless steel (SUS) Mounting Bracket (with screws), Instruction sheet

5 Engineering Data (Typical) EG-L/L Operating Range Spot Diameter vs. Sensing Distance (in NORMAL Mode) (in ZE Mode) Operating range Y (mm) Setting distance: mm, mm, mm Sensing object: White, mm mm Operating range Y (mm) Setting distance: mm mm mm mm mm Spot diameter (mm). mm X Y. mm mm. Distance X (mm) Distance X (mm) EG-L@ (in NORMAL Mode) EG-L@ (in ZE Mode) EG-L@ Operating range Y (mm) Setting distance: mm, mm, mm Sensing object: White, mm mm X Y Operating position Y (mm) Setting distance: mm, mm, mm mm Spot diameter (mm) Distance (mm) 8 mm mm mm mm Angle Characteristics Distance X (mm) Distance X (mm) EG-L@ (Vertical) EG-L@ (Horizontal) EG-L@ Sensing object: White, mm Sensing distance: mm Vertical +θ θ Sensing object Center line (θ) Sensing object: White, mm Sensing distance: mm Vertical +θ θ Sensing object Center line (θ) EG-L@ (Vertical) EG-L@ (Horizontal) EG-L@ Sensing object: White, mm Sensing distance: mm Sensing object: White, mm Sensing distance: mm 8 8 Distance (mm) Sensing Object Size vs. Setting Distance Min. sensing object dia. (mm) Min. sensing object dia. (mm)..... Sensing object: Stainless steel rod Setting distance: white, mm Distance (mm). Sensing object: Stainless steel rod Setting distance: white, mm. (Vertical) Sensing object Center line (θ) (Horizontal) +θ θ Sensing object Center line (θ). 8 8 Distance (mm)

6 EG-L/L Angle Characteristics Close-range Characteristics (Vertical) (Horizontal) 8 Sensing object: White, mm Sensing distance: mm Vertical +θ θ 8 Sensing object Center line (θ) 8 Sensing object: White, mm Sensing distance: mm Horizontal +θ θ 8 Sensing object Center line (θ) EG-L@ (Vertical) EG-L@ (Horizontal) EG-L@ 8 Sensing object: White, mm Sensing distance: mm Sensing object Center line Vertical (θ) Sensing object: White, mm 8 Sensing distance: mm mm White White Sensing Distance vs. Sensing Object EG-L@ (at -mm Setting Distance) EG-L@ (at -mm Setting Distance) EG-L@ (at -mm Setting Distance) Horizontal +θ θ 8 Sensing object Center line (θ) Setting distance: mm Setting distance: mm mm mm 8 mm mm mm mm mm Setting distance: mm Setting distance: mm mm 78 mm mm 8. mm 8. mm 9 mm mm White White mm White Veneer Fiberboard rubber Mirror White Veneer Fiberboard rubber Mirror White Veneer Fiberboard rubber Mirror EG-L@ (at -mm Setting Distance) EG-L@ (at -mm Setting Distance) EG-L@ (at -mm Setting Distance) White Veneer Fiberboard rubber Mirror White Veneer Fiberboard rubber Mirror White Veneer Fiberboard rubber Mirror

7 I/O Circuit Diagrams EG-L/L NPN Output Model Operation mode Timing charts Mode selector switch Output circuit EG-L EG-L EG-L EG-L Light- Dark- Incident light No incident light Operation indicator Output transistor Load Operate (e.g., relay) Reset (Between brown and black) Incident light No incident light Operation indicator Output transistor Load Operate (e.g., relay) Reset (Between brown and black) L- (LIGHT ) D- (DARK ) 8-level -level distance threshold indicator indicator (green) (red) Operation indicator Photoelectric main circuit Brown to VDC NPN output transistor Load Control ma output max. ZD Blue Connector Pin Arrangement V Note: Pin is not used. PNP Output Model Operation mode Timing charts Mode selector switch Output circuit EG-L EG-L EG-L EG-L Light- Dark- Incident light No incident light Operation indicator Output transistor Load (e.g., relay) Operate Incident light No incident light Operation indicator Output transistor Load (e.g., relay) Reset (Between blue and black) Operate Reset (Between blue and black) L- (LIGHT ) D- (DARK ) 8-level -level distance threshold indicator indicator (green) (red) Operation indicator Photoelectric main circuit Connector Pin Arrangement ZD PNP output transistor Brown to VDC Blue ma max. Control output Load V Note: Pin is not used. Plugs ( I/O Connectors) Pin No. XSF-M--A XSF-M--A XSF-M--A XSF-M--A Wire colors Blown White Blue Classification Wire color Connector pin No. Application Blown Power supply (+ V) DC White --- Blue Power supply ( V) Output Note: Pin is not used. Nomenclature UP/DOWN selector switch Selects the switching direction at threshold. Operation indicator Lit when output is. Distance indicator (green) Displays the distance relative to the threshold. Threshold indicator (red) Indicates threshold level. SET button Used for teaching or for threshold adjustment. ZE D Operation mode selector switch Selects L- or D-. NORMAL/ZE selector switch Selects the detection mode. Mode selector switch Selects the mode. 7

8 Adjustments EG-L/L Adjustment Procedure Step Operation Install, wire, and turn the. Perform distance setting (teaching). Refer to Distance Setting (Teaching), below. Make a fine adjustment of the threshold, if necessary. Refer to Manual Teaching (Fine Distance Setting). Page Check that the mode selector switch is set to. Distance Setting (Teaching) Select the most appropriate teaching method in reference to the following descriptions. Application Teaching without sensing objects (i.e., teaching the background). Detection of slight differences in surface level. Setting a threshold in the middle between the background and sensing object for operation. Detection of glossy objects in front of the background. Teaching Normal one-point teaching Normal two-point teaching Zone one-point teaching Setting method TEACH Press the background object. button with the TEACH Press the button with the background object and with the sensing object. TEACH Press the button with the background object (conveyor, etc.). Object Set threshold Threshold (a) is set immediately in front of the background. Threshold (a) is set approximately in the middle between the background and sensing object. A pair of thresholds, (a) and (b), are set. The output is between the and La. The output is between the and La. The output is between La and Lb. EG-L EG-L D- L- EG-L Output range Threshold a (La) Threshold a (La) Threshold a (La) Threshold b (Lb) La: Distance equivalent to threshold (a) Lb: Distance equivalent to threshold (b) The following settings are also possible: Setting the maximum sensing distance of the : Maximum distance setting. Setting the minimum differential travel of the : Minimum distance setting. Distance from to background must not exceed the values shown below during normal one-point or zone one-point teaching. Model EG-L@ EG-L@ Distance from to background mm min. mm min. Maximum sensing distance of the EG-L@ may differ depending on the color of the sensing object when setting distance is more than mm. Confirm the operation of the before actual operation. 8

9 EG-L/L Normal One-point Teaching EG-L Threshold a (La) Step Operation Panel status Set the mode selector switch to TEACH. Set the NORMAL/ZE mode selector switch to NORMAL. Press the SET button with the background. ZE D The threshold indicator (red) will turn. Threshold indicator (red) turns. Set the mode selector switch to. Set to L- or D- mode with the operation mode selector switch. L-: Output between background and. D-: Output between background and. Press Application Example Adjusting the differential travel to the minimum distance. Set the mode selector switch to TEACH. Set the NORMAL/ZE mode selector switch to NORMAL. Set the UP/DOWN selector switch to DOWN. Press the SET button for at least s. The threshold indicator (red) will turn. The distance indicator (green) will turn. This means that teaching is successful. Set the mode selector switch to to complete the teaching operation. ZE D Press Press the SET button for s or more. Set the mode selector switch to. Set to L- or D- mode with the operation mode selector switch. (Refer to Normal One-point Teaching) Threshold indicator (red) turns. Distance indicator (green) turns. Application Example Setting the to the maximum distance. Set the mode selector switch to TEACH. Set the NORMAL/ZE mode selector switch to NORMAL. Set the UP/DOWN selector switch to UP. Press the SET button for s or more. The threshold indicator (red) will turn. The distance indicator (green) will turn. This means that teaching is successful. Set the mode selector switch to to complete the teaching operation. ZE D Press Press the SET button for s or more. Set the mode selector switch to. Set to L- or D- mode with the operation mode selector switch. (Refer to Normal One-point Teaching) La: Distance equivalent to threshold (a) Threshold indicator (red) turns. Distance indicator (green) turns. 9

10 EG-L/L Normal Two-point Teaching EG-L Object Object Threshold a (La) Step Operation Panel status Set the mode selector switch to TEACH. Object Set the NORMAL/ZE mode selector switch to NORMAL. Press the SET button with a sensing object located at sensing position. The threshold indicator (red) will turn. Move the sensing object and press the SET button with the background. If the teaching is successful, the distance indicator (green) will turn. If the teaching is not successful, the threshold indicator (red) will start to flash. If the teaching is successful, set the mode selector switch to to complete the teaching operation. If the teaching is not successful, change the position of the object and setting distance that have been set and repeat from the above step. Set to L- or D- mode with the operation mode selector switch. ZE D Press ZE D OK NG Threshold indicator (red) turns. Distance indicator (green) turns. Threshold indicator (red) starts to flash. Press La: Distance equivalent to threshold (a) Zone One-point Teaching EG-L Threshold a (La) Threshold b (Lb) Step Operation Panel status Set the mode selector switch to TEACH. Set the NORMAL/ZE mode selector switch to ZE. Press the SET button with the background. All threshold indicators (red) will turn OK while the SET button is pressed. When the SET button is released: ZE D If the teaching is successful, the distance indicator (green) will turn. If the teaching is not successful, the threshold indicator (red) will start to flash. Set the mode selector switch to. Set to L- or D- mode with the operation mode selector switch. L-: Output with the background. D-: Output with the background. La: Distance equivalent to threshold (a) Press NG Distance indicator (green) turns. Threshold indicator (red) starts to flash.

11 EG-L/L Manual Teaching (Fine Distance Setting) Step Operation Panel status Fine adjustment of the threshold is possible after teaching. Set the mode selector switch to. Set the adjustment direction in the mode with the UP/DOWN selector switch. The threshold changes each time the SET button is pressed. The setting can be made in up to levels (for normal one-point or two-point teaching). After the adjustment is complete, set the mode selector switch to. ZE D Press SET pressed with UP/ DOWN selector switch set to UP. SET pressed with UP/ DOWN selector switch set to DOWN. Threshold increases. Threshold decreases. Threshold Indicator Display during Distance Adjustment Max. adjustment levels for normal teaching. Level Threshold indicators Five adjustment levels for zone teaching. Threshold indicators Level Threshold and Distance Indicator Displays Display for Distance Setting with Normal One-point or Two-point Teaching The distance indicators show the distance level. The distance indicators show distances relative to the threshold. The threshold can be shifted using the UP/DOWN selector and SET button. The differential travel cannot be changed. Display for Distance Setting with Zone Teaching The distance indicators show the current distance band. The distance indicators show distances relative to the threshold. The range can be shifted using the UP/DOWN selector and SET button. The differential travel cannot be changed. UP UP Control output: UP UP Control output: DOWN DOWN DOWN (No change) Control output:

12 Safety Precautions WANINNG This product is not designed or rated for ensuring safety of persons. Do not use it for such purpose. Precautions for Correct Use Do not use the product in atmospheres or environment that exceed product ratings. Wiring Cable The bending radius of the cable must be no smaller than mm. Avoiding Malfunctions If using the Photoelectric with an inverter or servomotor, be sure to ground the FG (frame ground) and G (ground) terminals, otherwise the may malfunction. Mounting Mounting Conditions If s are mounted face-to-face, make sure that no optical axes cross each other. Otherwise, mutual interference may result. Be sure to install the carefully so that the directional range of the will not be directly exposed to intensive light, such as sunlight, fluorescent light, or incandescent light. Do not strike the Photoelectric with a hammer or any other tool during the installation of the, or the will loose its water-resistant properties. Use M screws to mount the. When mounting the case, make sure that the tightening torque applied to each screw does not exceed. N m. M8 Connector Always turn the before connecting or disconnecting the M8 connector. Be sure to hold the connector cover when connecting or disconnecting the M8 connector. Secure the M8 connector by hand. Do not use any pliers, otherwise the connector may be damaged. If the M8 connector is not connected securely, the M8 connector may be disconnected by vibration or the proper degree of protection of the may not be maintained. Mounting Directions Make sure that the sensing side of the is parallel with the surface of each sensing object. Do not incline the towards the sensing object. If the sensing object has a glossy surface, incline the by to as shown below, provided that the is not influenced by any background objects. Sensing side Surface of sensing object EG-L/L If there is a mirror-like object below the, the may not be in stable operation. Therefore, incline the or keep the a distance away from the mirrorlike object as shown below. Make sure not to install the in the incorrect direction. Refer to the following. Sensing object Sensing object Moving direction Mirror-like object Sensing object Moving direction Install the as shown in the following if each sensing object greatly differs in color or material. Moving direction Sensing object Moving direction Moving direction Adjustments If the is not in stable operation due to color differences, make a fine adjustment of the threshold level and confirm that operation is stable. Refer to Manual Teaching (Fine Distance Setting) Page Maintenance and Inspection Cleaning Paint thinner will damage the casing of the. Do not use paint thinner to clean the. Others EEPROM Writing Error If a teaching data error occurs with the operation indicator flashing due to a power failure or static noise, perform the teaching operation of the again. Water Resistivity To ensure the water resistivity of the, tighten the screws of the operation panel cover to a torque of. to. N m. Glossy object

13 EG-L/L Dimensions s (Unit: mm) Unless otherwise specified, the tolerance class IT is used for dimensions in this data sheet. Pre-wired Models EG-L/L EG-L/L With Mounting Bracket Attached. *A Two, R. Two, M. Distance indicators (green) Operation indicator 8 Threshold indicators (red) M. 7. * Mounting Bracket can be attached to side A Two, M Mounting Holes Two, 8-dia. lens Emitter 8. A* 7 Two, M through holes. Six, R. Optical axis Receiver B*. Two,. dia.. dia. -dia. (8/. dia.) vinyl-insulated round cable with three conductors, Standard length: m. 9. * Model A B EG-L@..88 EG-L@. Connector Models EG-L/L EG-L/L With Mounting Bracket Attached *A Two, M Two, R. 9.. Mounting Holes Distance indicators (green) Operation indicator 8 Threshold indicators (red) M.. * Mounting Bracket can be attached to side A Two, M Two, 8 -dia. lens Emitter 8. 7 Two, M through holes Six, R. A*. Two,. dia. 7. Optical axis Receiver B* dia. M8 Connector. * Model A B EG-L@..88 EG-L@. Accessories (Order Separately) Mounting Brackets In the interest of product improvement, specifications are subject to change without notice.

14 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMR representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMR's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMR. OMR MAKES NO WARRANTY OR REPRESENTATI, EXPRESS OR IMPLIED, REGARDING N-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMR DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIS OF LIABILITY OMR SHALL NOT BE RESPSIBLE FOR SPECIAL, INDIRECT, OR CSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED CTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMR for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMR BE RESPSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMR'S ANALYSIS CFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CTAMINATI, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATI OR REPAIR. Application Considerations SUITABILITY FOR USE OMR shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMR will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATI INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITH ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMR PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMR shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMR representative at any time to confirm actual specifications of purchased products. DIMENSIS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMR s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMR Warranty and Limitations of Liability. ERRORS AND OMISSIS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMR Corporation Industrial Automation Company In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMR Corporation 8 All Right Reserved.

15 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: E9-L9 E9-L EG-L

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm)

E8AA. Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications. Pressure Sensor (Stainless Steel Diaphragm) Pressure Sensor (Stainless Steel Diaphragm) CSM DS_E_3_1 Pressure Sensor of Stainless Steel Construction Is Ideal for a Wide Range of Applications Incorporates double diaphragms consisting of SUS316L stainless

More information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information Liquid Level EK-L CSM_EK-L_DS_E 3 Liquid Level That Is Unaffected by the Color of the or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to mm or to mm Built-in Amplifiers to save space.

More information

onlinecomponents.com

onlinecomponents.com Mounting Brackets E-L/F-L Slits/Reflectors E-S/E-R CSM_E-L_F-L_E-S_E-R_DS_E Mounting Brackets [Refer to Dimensions on page.] Model Fitting materials Count E-L Iron, zinc plating Accessories Applicable

More information

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073

Operating instructions Safety Rope Emergency Stop Switches ZB0052 / ZB0053 ZB0072 / ZB0073 Operating instructions Safety Rope Emergency Stop Switches UK ZB0052 / ZB0053 ZB0072 / ZB0073 7390878 / 02 03 / 2011 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4

More information

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure

The Limit Switch with Better Seal, Shock Resistance, and Strength. General-purpose Limit Switch. Model Number Structure General-purpose Limit Switch CSM_DA-_N_DS_E The Limit Switch with Better Seal, Shock Resistance, and Strength A double seal on the head, a complete gasket cover, and other features ensure a better seal

More information

Norrsken Family Booklet

Norrsken Family Booklet Section 1: Introduction Low Energy Designs produce efficient and effective LED based lighting products for commercial, retail and industry purposes. Each product may contain specific details on its operation

More information

E2B PROXIMITY SENSORS

E2B PROXIMITY SENSORS E2B PROXIMITY SENSORS Enjoy innovation and reliability today» Time and cost savings» Perfect fit for standard environments» New LITE inductive sensor 2 3 Quality, reliability and value-for-money We asked

More information

General-purpose Relays and Power Relays Sockets

General-purpose Relays and Power Relays Sockets General-purpose Relays and Power Relays Sockets Relay Type Track Mount Sockets Back Connecting Sockets Solder terminals PCB terminals G2R-1-S P2RF-05 P2RF-05-E P2RF-05-S P2R-05A P2R-05P G2R-2-S P2RF-08

More information

QPL... Pressure Switches. Siemens Building Technologies HVAC Products

QPL... Pressure Switches. Siemens Building Technologies HVAC Products 7 221 Pressure Switches QPL... The pressure switches are used for monitoring gas or air pressures. When the pressure falls below the switching point, the associated electrical circuit will open or switch

More information

User Manual V14.1 IP68 LED FLEX NEON

User Manual V14.1 IP68 LED FLEX NEON User Manual V14.1 IP68 LED FLEX NEON PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION LEAVE A COPY FOR THE END USER/MAINTENANCE ENGINEER FOR FUTURE REFERENCE 1/11 PRODUCT SPECIFICATION 1. Operating

More information

E3F2 Series DC Cylindrical M18 Photoelectric Sensors to be Discontinued March 2014; Replace with E3FA or E3FB

E3F2 Series DC Cylindrical M18 Photoelectric Sensors to be Discontinued March 2014; Replace with E3FA or E3FB NO: PH-177 PRODUCT: E3F2 DC Photoelectric Sensors DATE: May 2013 TYPE: Partial Discontinuation Notice E3F2 Series DC Cylindrical M18 Photoelectric Sensors to be Discontinued March 2014; Replace with E3FA

More information

DPS-400 SERIES DPH-100 SERIES

DPS-400 SERIES DPH-100 SERIES 745 Dual Display Digital Pressure Sensor For Gas DPS-400 SERIES SERIES General terms and conditions... F- guide... P.699~ Related Information Glossary of terms... P.156~ General precautions... P.1566 PHOTO

More information

PyroCouple Series Operators Guide

PyroCouple Series Operators Guide PyroCouple Series Operators Guide english PyroCouple, non-contact infrared sensors measure temperatures from -20 C to 500 C and provide either a linear 4 to 20mA output, a voltage output or a thermocouple

More information

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions

PLAQUE MFM0680 UNDERWATER LIGHT. Operating Instructions PLAQUE MFM0680 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM0680... 4 Power Supply Unit MPS021000

More information

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions

METEOR LSR36500 LIGHTING UNDERWATER POOL LIGHT. Operating Instructions METEOR LSR36500 UNDERWATER POOL LIGHT Operating Instructions LIGHTING CONTENTS Preface...3 Features...3 Precautions...3 Components and Connectors...4 Installation...5 Controls...7 Appearance...8 Technical

More information

M-5071/1111. Electronic Pressure Switch PSW14 series

M-5071/1111. Electronic Pressure Switch PSW14 series M-507/ Electronic Pressure Switch PSW4 series S TABLE OF CONTENTS Electronic Pressure Switch PSW4 Series Intended Applications... Safety Instructions... 3 Standards... 4 Warranty/Guaranty... 5 Installation/Commissioning...

More information

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL TFS SERIES FLOW METER INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS PLEASE READ THE FOLLOWING INFORMATION PRIOR TO INSTALLING AND USING HAYWARD TFS SERIES FLOW METERS. FAILURE

More information

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG36KTL-M Quick Installation Guide. 1 Unpacking and Inspection SG36KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG36KTL-M. In no case shall this guide substitute for the user manual or related notes on

More information

INSTRUCTION MANUAL Pressure Relief Device LPT

INSTRUCTION MANUAL Pressure Relief Device LPT INSTRUCTION MANUAL Pressure Relief Device LPT 5COV475800 LPT REV00 CONTENT: 1 SAFETY 1.1 Safety instructions 2 1.2 Specified applications 2 1.3 Safety notes on the equipment operation 2 2 PRESSURE RELIEF

More information

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor 2-Color Display High-Precision Digital Pressure Switch Series ZSEA(F)/EA ZSE E RoHS New IP65 ZSE E ZSE0 E0 M8 connector type E70 ZSE E E Applicable Air, Non-corrosive gas, Non-flammable gas fluid Can copy

More information

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection

SG33KTL-M Quick Installation Guide. 1 Unpacking and Inspection SG33KTL-M Quick Installation Guide This guide provides a general instruction of the installation procedures of SG33KTL-M. In no case shall this guide substitute for the user manual or related notes on

More information

MANUAL KPS Pressure Control Valve

MANUAL KPS Pressure Control Valve TetraTec Instruments GmbH Gewerbestrasse 8 71144 Steinenbronn Deutschland E-Mail: info@tetratec.de Tel.: 07157/5387-0 Fax: 07157/5387-10 MANUAL Pressure Control Valve *** VERSION 1.0 *** Update: 17.11.2006

More information

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr

INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr INSTRUCTION MANUAL MP4AR Remote Convection Gauge Range: 1 x 10-3 Torr to 1 x 10+3 Torr A DIVISION OF THE FREDERICKS COMPANY 2400 PHILMONT AVE. HUNTINGDONVALLEY, PA 19006 PARTS LIST 1 3 4 2 # QTY ITEM DESCRIPTION

More information

Digital Melting Point Apparatus

Digital Melting Point Apparatus Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature

More information

Digital Flow Switch. Series PFM7

Digital Flow Switch. Series PFM7 Compatible with rgon (r), Carbon Dioxide (CO) and the Mixed Gas (r+co) Digital Flow witch eries PFM7 Flow adjustment valve Fluid r, CO r + CO RoH -color display ee abnormal values at a glance. llows flow

More information

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC #

E X R A D I N Spherical Ion Chambers A3. A4 REF DOC # E X R A D I N Spherical Ion Chambers A3. A4 REF 92717. 92715 R DOC #80360-00 E X R A D I N Spherical Ion Chambers A3. A4 REF 92717. 92715 STANDARD IMAGING INC. 7601 Murphy Drive Middleton, WI 53562 TEL

More information

NO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice

NO: REL-149 PRODUCT: G8P Series PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice NO: REL-149 PRODUCT: PCB Power Relay DATE: November 2014 TYPE: Discontinuation Notice G8P PCB Power Relays to be DISCONTINUED April 30, 2015 Due to a diminishing global demand for the G8P series PCB Power

More information

Verdi G-Series Family

Verdi G-Series Family Verdi G-Series Family High-Power Pumps for Ti:Sapphire Lasers and Amplifiers Applications such as ultrafast spectroscopy, multiphoton microscopy, terahertz imaging, and Optical Coherence Tomography (OCT)

More information

GasSense NDIR User Manual

GasSense NDIR User Manual INDEX INDEX... 1 1. OVERVIEW... 2 2. TECHNICAL DATA... 3 3. SPECIFICATIONS... 4 4. PRODUCT DESCRIPTION... 5 4.1 Mechanical details... 5 4.2 Piping... 7 4.3 Connections... 7 5. INSTALLATION... 10 6. CALIBRATION

More information

Dual Solenoid Gas Valve Installation

Dual Solenoid Gas Valve Installation Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing FLYNN Gas Products. Carefully follow all instructions in this bulletin and all instructions

More information

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide

OSAT Series. Intrinsically Safe Infrared Temperature Sensor Operator's Guide OSAT Series Intrinsically Safe Infrared Temperature Sensor Operator's Guide Issue L Jan 2017 Introduction OSAT Series intrinsically safe non-contact infrared temperature sensors measure the temperature

More information

MODELS (2 foot Version) (4 foot Version)

MODELS (2 foot Version) (4 foot Version) INSTALLATION AND MAINTENANCE MANUAL DUROSITE LED LINEAR FIXTURE Document No: 9100-127-2571-99 Rev A April, 2016 MODELS (2 foot Version) (4 foot Version) ALL LAE ALL LBE These instructions contain important

More information

Compact Pressure Switch

Compact Pressure Switch Compact Pressure Switch Series 2 (For Vacuum)/ 2 (For Positive Pressure) For General Pneumatics Can be integrated with ZX or ZR ejector system. A Easy and simple wiring Connector type 77 Compact Pressure

More information

Further technical information is available on

Further technical information is available on 1 of 5 Manufacture address : Bartec Technor AS Dusavikveien 39 4007 Stavanger Norway Further technical information is available on www.bartec-technor.no Note on instructions When working in hazardous areas,

More information

USER MANUAL. JET TST and JET TST S.

USER MANUAL. JET TST and JET TST S. USER MANUAL JET TST and JET TST S www.sisteven.com Types of Jet fans: JET TST UNI: Impulse axial fan single direction JET TST S UNI: Impulse axial fan single direction (short case) JET TST REV: Impulse

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES

Verdi G-Series. High-Power Pumps for Ti:Sapphire Lasers and Amplifiers FEATURES Verdi G-Series High-Power Pumps for Ti:Sapphire Lasers and Amplifiers The Verdi G is a high performance CW laser providing up to 20W at 532 nm, ideal for pumping Ti:Sapphire lasers and amplifiers, for

More information

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars.

better measurement Simply a question of SCHMIDT Flow Sensor SS The cost-effective alternative in pressurised systems up to 10 bars. Simply a question of better measurement SCHMIDT Flow Sensor SS 20.261 The cost-effective alternative in pressurised systems up to 10 bars. Compressed air technology Industrial processes A cost analysis

More information

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e

Mounting instructions. Strain transducer SLB-700A. B 26.SLB700A.10 e Mounting instructions Strain transducer SLB-700A B 26.SLB700A.10 e SLB700A 3 Contents Page Safety instructions.............................................. 4 1 Applications..................................................

More information

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions

PLAQUE MFM18240 UNDERWATER LIGHT. Operating Instructions PLAQUE MFM18240 UNDERWATER LIGHT Operating Instructions CONTENTS Preface... 3 Features... 3 Precautions... 3 Controls and Connectors... 4 Underwater Light PLAQUE MFM18240... 4 Power Supply Unit MPS061000

More information

SPECIFICATIONS ATTENTION

SPECIFICATIONS ATTENTION VPS 504 S06 Installation Manual - P/N 80122 - Ed. 01/09 VPS 504 S06 and S05 Valve Proving System Installation Instructions VPS 1 6 Gases Natural gas, air and other inert gases. NOT suitable for butane

More information

Technical Data. Dimensions

Technical Data. Dimensions 00 Model Number Features mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

Instruction Manual BA90 Precision Barometer

Instruction Manual BA90 Precision Barometer Instruction Manual BA90 Precision Barometer halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Germany Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

DIRECTIONS FOR USE / ASSEMBLING

DIRECTIONS FOR USE / ASSEMBLING ELECTRIC HEIGHT ADJUSTABLE DESK ConSet - MODEL 01-2/27/29/2, -LEG (PAT. PENDING) DIRECTIONS FOR USE / ASSEMBLING EN WARNING WARNING: FAILURE TO COMPLY WITH OR OBSERVE ALL ASSEMBLY, SAFETY AND OPERATION

More information

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual

Sensor for Air Bubble Detection at Liquid Filled Tubes. SONOCHECK Type ABD06.xx. Operating Manual Sensor for Air Bubble Detection at Liquid Filled Tubes SONOCHECK Type ABD06.xx Operating Manual Manufacturer: Model: Type: SONOTEC Ultraschallsensorik Halle GmbH Air Bubble Detector ABD06.xx SONOTEC Ultraschallsensorik

More information

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. General specifications. Rated operating distance s n 5 mm 0102 Model Number Features 5 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-18 Quick mounting bracket with dead stop BF 18 Mounting flange, 18 mm Technical Data specifications Switching

More information

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:

INSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel: PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual 1194 Oak Valley Drive, Suite 20, Ann Arbor, MI 48108 800-959-0573 734-769-1888 Content Page For your Safety 3 General Description 3 Detection Principle 4 Operation 4

More information

Position switches FP series

Position switches FP series A Position switches FP series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere adjustable lever safety adjustable lever

More information

Sensoric 4-20 ma Transmitter Board Operation Manual

Sensoric 4-20 ma Transmitter Board Operation Manual Sensoric 4-20 ma Transmitter Board Operation Manual 1 Content Features Operation Manual Technical Data Mechanical Dimensions Remarks & Contact information 2 Features Soldered sensor cell (non replaceable)

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

ASDX Series Silicon Pressure Sensors

ASDX Series Silicon Pressure Sensors ASDX Series Silicon Pressure Sensors DESCRIPTION The ASDX Series is a Silicon Pressure Sensor offering a ratiometric analog interface for reading pressure over the specified full scale pressure span and

More information

Digital electro-pneumatic regulators Series ER100

Digital electro-pneumatic regulators Series ER100 CATALOGUE > Release 8.2 Digital electro-pneumatic regulators Series ER100 TREATMENT > Digital electro-pneumatic regulators Series ER100 Port G1/4» Compact design» Digital display» Analog and digital input»

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm

Technical Data. General specifications Switching element function Rated operating distance s n 2 mm 0102 Model Number Features 2 mm flush Usable up to SIL 2 acc. to IEC 61508 Accessories EXG-12 Quick mounting bracket with dead stop BF 12 Mounting flange, 12 mm Technical Data specifications Switching

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operation Manual WIKA FLR-SBDF / BLR-SBDF Magnetic Level Transmitter (Please retain for future usage) Contact: Gayesco-WIKA USA, L.P. 229 Beltway Green Boulevard Pasadena, TX 77503 www.wika.com

More information

Pressure Sensor PSE53#

Pressure Sensor PSE53# PRODUCT NAME Pressure Sensor MODEL / Series / Product Number PSE53# Table of Contents Safety Instructions 2 Model Identification and how to order 8 Definition and terminology 8 Mounting and Installation

More information

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor

Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor Instruction Manual AD 1000 / BA 1000 Absolute Pressure Sensor halstrup-walcher GmbH Stegener Straße 10 D-79199 Kirchzarten Phone: +49 (0) 76 61/39 63 0 Fax: +49 (0) 76 61/39 63 99 E-Mail: info@halstrup-walcher.com

More information

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS

OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS OPERATION AND INSTRUCTION MANUAL Flat Roof Anchor Model: FRA250L-10X-CTS (Patent Pending) WARNING: ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS. FAILURE TO DO SO MAY RESULT

More information

Manual Leveling Control Installation/Operation

Manual Leveling Control Installation/Operation ELECTROMECHANICAL TRIM TAB SYSTEMS Manual Leveling Control Installation/Operation Linear Devices Corporation dba Lectrotab 11126 Air Park Road, Suite G Ashland, VA 23005 www.lectrotab.com Phone: 804-368-8428

More information

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Dimensions. Technical Data General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm Dimensions 65 GW2 40 35 9 5 GW1 14 11 9 5.4 M20 x 1.5 0102 Model Number S M12 x 1.5 Features 77.5 LED V Direct mounting on standard actuators Compact and stable housing with terminal compartment connection

More information

A4s Operation Manual

A4s Operation Manual A4s Operation Manual Safety Instruction Please read this manual carefully, also with related manual for the machinery before use the controller. For installing and operating the controller properly and

More information

Precision pressure sensor Basic version Model CPT6020

Precision pressure sensor Basic version Model CPT6020 Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications

More information

Product Information. Gripper for small components MPC

Product Information. Gripper for small components MPC Product Information MPC MPC Easy. Economical. Cost-effective. MPC Easily built up 2-finger parallel gripper with good price-performance ratio Field of application Gripping of small to mid-sized workpieces

More information

VACUUM REGULATORS CONTENTS

VACUUM REGULATORS CONTENTS CAD drawing data catalog is available. ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Small Regulators Features 759 Specifications, Order Codes, Flow Rate

More information

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983

Product information. Capacitive. Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69. Document ID: 29983 Product information Level detection in liquid VEGACAP 62 VEGACAP 63 VEGACAP 64 VEGACAP 66 VEGACAP 69 Document ID: 29983 Contents Contents 1 Description of the measuring principle... 3 2 Type overview...

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

RTD Temperature sensor TH11

RTD Temperature sensor TH11 RTD Temperature sensor TH11 Compact Instructions Measuring System General purpose RTD with connection head TH11 for process and laboratory applications. The single element RTD is specifi cally designed

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions

HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions For the following Models: 40A00-1 HAI 15A Relay Switch (referred to as HAI UPB Wall Switch, in this document), and

More information

RPS900W Redundant Power Supply. Installation Guide.

RPS900W Redundant Power Supply. Installation Guide. RPS900W Redundant Power Supply Installation Guide www.edge-core.com Installation Guide RPS900W Redundant Power Supply Single DC Output Port with Dual Output Voltages RPS900W E10013-CS-R01 1500000081A

More information

REFERENCE SPECIFICATION

REFERENCE SPECIFICATION 1 / 8 1. Notification Items 1.1 Law and the regulation which are applied 1 Ozone depleting substances specified by Montreal Protocol have not been used in the manufacturing process of the material used

More information

Pre-filter for Brushless Blower Instruction Manual

Pre-filter for Brushless Blower Instruction Manual Pre-filter for Brushless Blower 781-70-702 Instruction Manual Minebea Co., Ltd. Industrial Machinery Business Unit 251-8531 1-1-1 Katase,Fujisawa,kanagawa Contact Us Industrial Machinery Product Sales

More information

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm 00 Model Number Features 5 mm flush Usable up to SIL acc. to IEC 6508 Accessories V-G Female connector, M, -pin, field attachable V-W Female connector, M, -pin, field attachable V-G-N-M-PUR Female cordset,

More information

CFSW. Hinges with built-in safety multiple switch

CFSW. Hinges with built-in safety multiple switch CFSW. Hinges with built-in safety multiple switch ELESA Original design Elesa Standards Main dimensions Fitting Weight Code Description L B f ±0.2 f 1 ±0.2 H h 1 h 2 d 3 d 4 C [Nm]# g 426601 CFSW.110-6-2NO+2NC-C-A

More information

Operating Instructions

Operating Instructions LPL Series LED Pendant Lighting Operating Instructions IM0102 COOPER Electronic Technologies (Shanghai) Co., Ltd. No. 955 Shengli Road, East Area of Zhangjiang High-Tech Park, Shanghai 201201 China 1.

More information

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50

Operation manual Level sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50 Operation Manual Level Sensor DC-LS-50 Rev.02 (2014.06) OL Page 1 of 8 Table of contents I. STRUCTURE OF THE MANUAL / CLARIFICATION... 3 II. SAFETY AND HEALTH CONCERNS... 4 1 INTRODUCTION... 5 1.1 Use

More information

Zelio Relays RSL Slim Interface Plug-In Relays

Zelio Relays RSL Slim Interface Plug-In Relays Zelio Relays RSL Slim Interface Plug-In Relays Catalog 8501CT0901 2009 Class 8501 CONTENTS Description............................................. Page Introduction.................................................3

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

User s Guide Temperature Sensor Converter TSC-599

User s Guide Temperature Sensor Converter TSC-599 User s Guide Temperature Sensor Converter TSC-599 ILX Lightwave Corporation 31950 Frontage Road Bozeman, MT, U.S.A. 59715 U.S. & Canada: 1-800-459-9459 International Inquiries: 406-556-2481 Fax 406-586-9405

More information

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11

Socket P2RF-05-S P2RF-08-S Clip & Release Lever Nameplate R99-11 Screwless Clamp Terminal Socket P2RF@@S Screwless clamping greatly contributes to reducing wiring time. No over or under tightening of cable connection so better contact reliability is achieved. Double

More information

2000 lb manual winch

2000 lb manual winch 2000 lb manual winch Model 41694 Operation Instructions Due to continuing improvements, actual product may differ slightly from the product described herein. 3491 Mission Oaks Blvd., Camarillo, CA 93011

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES

CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES I N S T R U C T I O N - M A N U A L CONDUCTIVITY POINT/S LEVEL SWITCH JAYCEEAQUA 4000 SERIES FUNCTION: Conductivity level limit switches are based on the principle of measuring level through the electrical

More information

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING

PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING PULSAR 5000 SERIES OPERATING & INSTALLATION INSTRUCTIONS SERIES 5000 PLEASE READ CAREFULLY BEFORE INSTALLING Please Note: Ranges above 500mbar are designed and manufactured in accordance with sound engineering

More information

AutoChanger Installation & User Guide Issue 2

AutoChanger Installation & User Guide Issue 2 1 INDEX Page 1. Introduction... 3 2. AutoChanger Components Guide 4 3. Installation. 5-11 a) Installation Guidelines.. 5 b) Installation Retrofit... 6-11 c) Installation New... 11 4. AutoChanger User Guide

More information

Transmitter CS 21 Operation Manual

Transmitter CS 21 Operation Manual Transmitter CS 21 Operation Manual Content Page For your Safety 3 General Description 3 Detection Principle 4 Operational Notes 4 Design 4 Mounting Position of CS21 5 Mounting 6 Installation of Electrical

More information

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A

New Product. Air Consumption 70% Down. Precision Regulator Air Saving Type. RPE Series PRECISION REGULATOR RPE SERIES CC-1072A Air Consumption 70% Down New Product Precision Regulator Air Saving Type RPE Series PRECISION REGULATOR RPE SERIES Large Air Saving CC-1072A Air Consumption 70% Down. New Type Eco-friendly Precision Regulator

More information

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc.

LTB013EN. Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. LTB013EN Operating Instruction Trimod Besta Level Switch types XA 5, XB 5 for use in potentially explosive atmospheres acc. to IECEx scheme Subject to technical modification Bachofen AG Ackerstrasse 42

More information

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor

For Air Pressure. AP-30 Series. Digital Display & Digital Control. EASY-TO-SEE 2-color display. Two-color digital display pressure sensor Cat No AP3-KA-C Two-color digital display pressure sensor AP-3 Series Digital Display & Digital Control For Air Pressure EASY-TO-SEE 2-color display Green and red two-color LED display clearly shows abnormal

More information

! Warning, refer to accompanying documents.

! Warning, refer to accompanying documents. About this Manual To the best of our knowledge and at the time written, the information contained in this document is technically correct and the procedures accurate and adequate to operate this instrument

More information

Technical Specifications

Technical Specifications No. : PS##-OMG0006 Technical Specifications PSE560 series Contents Safety.P2 Model Indication Method.P6 Specification.P7 Full View with Dimensions.P8 Installation.P9 Examples of Internal Circuit and Wiring.P10-1

More information

Electronic relative and differential pressure switch type 616

Electronic relative and differential pressure switch type 616 Electronic relative and differential pressure switch type 616 Pressure range 0... 0.1 25 bar The switching points of the pressure switch type 616 can be potentiometer adjusted by the customer, or set in

More information

Cocoa Patio Pond with Lit Spillway

Cocoa Patio Pond with Lit Spillway Cocoa Patio Pond with Lit Spillway REMINDER CALL 1-888-755-5641 BEFORE RETURNING TO STORE. PACKAGE CONTENTS ITEM # GQSPPB/GQSPPW Questions, problems, missing parts? Before returning to your retailer, call

More information

2/ Port G1/4

2/ Port G1/4 CATALOGUE > Release 8.8 > Series ER100 digital electro-pneumatic regulators Series ER100 digital electro-pneumatic regulators Port G1/4 Compact design Digital display Analog and digital input Programmable

More information

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 MPS-1100 User Manual Mega Pool Saver Ltd PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 For further up to date instructions on how to install Mega Pool Saver MPS 1100, please

More information

Technical Data. Dimensions

Technical Data. Dimensions 0102 Model Number Features Comfort series 15 mm non-flush Stainless steel housing Accessories BF 30 Mounting flange, 30 mm Technical Data specifications Switching element function NAMUR, NC Rated operating

More information