Standard Pump SPFP30. Service & Operating Manual. 3" Food Processing. Original Instructions. SPFP30 Models SPFP30NPT SPFP30NPS SPFP30SSS SPFP30SST

Size: px
Start display at page:

Download "Standard Pump SPFP30. Service & Operating Manual. 3" Food Processing. Original Instructions. SPFP30 Models SPFP30NPT SPFP30NPS SPFP30SSS SPFP30SST"

Transcription

1 Standard Pump Service & Operating Manual Original Instructions 3" Food Processing SPFP30 Models SPFP30NPT SPFP30NPS SPFP30SSS SPFP30SST SPFP30 STANDARD PUMP, INC 1610 Satellite Blvd Suite D. Duluth, Ga Phone: (770) : CERTIFICATES 3: EXP VIEW 2: INSTAL & OP 1: PUMP SPECS

2 Safety Information IMPORTANT WARNING Read the safety warnings and instructions in this manual before pump installation and start-up. Failure to comply with the recommendations stated in this manual could damage the pump and void factory warranty. When the pump is used for materials that tend to settle out or solidify, the pump should be flushed after each use to prevent damage. In freezing temperatures the pump should be completely drained between uses. CAUTION Before pump operation, inspect all fasteners for loosening caused by gasket creep. Retighten loose fasteners to prevent leakage. Follow recommended torques stated in this manual. Nonmetallic pumps and plastic components are not UV stabilized. Ultraviolet radiation can damage these parts and negatively affect material properties. Do not expose to UV light for extended periods of time. WARNING Pump not designed, tested or certified to be powered by compressed natural gas. Powering the pump with natural gas will void the warranty. When used for toxic or aggressive fluids, the pump should always be flushed clean prior to disassembly. Before maintenance or repair, shut off the compressed air line, bleed the pressure, and disconnect the air line from the pump. Be certain that approved eye protection and protective clothing are worn at all times. Failure to follow these recommendations may result in serious injury or death. Airborne particles and loud noise hazards. Wear eye and ear protection. In the event of diaphragm rupture, pumped material may enter the air end of the pump, and be discharged into the atmosphere. If pumping a product that is hazardous or toxic, the air exhaust must be piped to an appropriate area for safe containment. Take action to prevent static sparking. Fire or explosion can result, especially when handling flammable liquids. The pump, piping, valves, containers and other miscellaneous equipment must be properly grounded. This pump is pressurized internally with air pressure during operation. Make certain that all fasteners are in good condition and are reinstalled properly during reassembly. Use safe practices when lifting kg Grounding the Pump To be fully groundable, the pumps must be ATEX Compliant. Optional 8 foot long (244 centimeters) Ground Strap is available for easy ground connection. To reduce the risk of static electrical sparking, this pump must be grounded. Check the local electrical code for detailed grounding instruction and the type of equipment required. WARNING Take action to prevent static sparking. Fire or explosion can result, especially when handling flammable liquids. The pump, piping, valves, containers or other miscellaneous equipment must be grounded.

3 Table of Contents SECTION 1: PUMP SPECIFICATIONS...1 Performance Materials Dimensional Drawings SECTION 2: INSTALLATION & OPERATION...4 Principle of Pump Operation Typical Installation Guide Troubleshooting SECTION 3: EXPLODED VIEW...7 Composite Drawings Parts List Materials Code SECTION 4: CERTIFICATES...11 EC Declaration of Conformity - Directive 2006/42/EC - Machinery EC Declaration of Conformity - Directive 94/9/EC - ATEX EC Declaration of Conformity - Directive 1935/2004/EC - Food Contact Materials 4: CERTIFICATES 3: EXP VIEW 1: PUMP SPECS 2: INSTAL & OP

4 Performance 1: PUMP SPECS Model SPFP30NPS & SPFP30SSS 3" Clamped - Food Processing FDA SANTOPRENE FITTED Flow Rate Adjustable to gpm (886 lpm) Port Size Suction... 3" TRI-CLAMP Discharge... 3" TRI-CLAMP Air Inlet...1/2" NPT Air Exhaust... 1" NPT Suction Lift Dry...20' (6.1 m) Wet....32' (9.8 m) Max Solid Size (Diameter)... 3/8" (9.5 mm) Max Noise Level...96 db(a) Shipping Weights Stainless lbs (86 kg) ** Stainless Center add lbs. (22.7 kg) Meters Feet BAR Discharge Head in PSI Displacement Per Stroke, 1.36 Gal. (5.1 L) 180 AIR CONSUMPTION IN SCFM AIR PRESSURE IN PSI SCFM M 3 /HR Capacity in U.S. Gallons Per Minute Capacity in Liters Per Minute NOTE: Performance based on the following: PTFE fitted pump, flooded suction, water at ambient conditions. The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%. Model SPFP30NPT & SPFP30SST 3" Clamped - Food Processing PTFE FITTED Flow Rate Adjustable to gpm (681 lpm) Port Size Suction... 3" TRI-CLAMP Discharge... 3" TRI-CLAMP Air Inlet...1/2" NPT Air Exhaust... 1" NPT Suction Lift Dry...12' (3.7 m) Wet....32' (9.8 m) Max Solid Size (Diameter)... 3/8" (9.5 mm) Max Noise Level...95 db(a) Shipping Weights Stainless lbs (86 kg) ** Stainless Center add lbs. (22.7 kg) Meters Feet BAR Discharge Head in PSI Capacity Per Stroke, 0.92 Gal. (3.5 L) AIR CONSUMPTION IN SCFM AIR PRESSURE IN PSI SCFM M 3 /HR Capacity in U.S. Gallons Per Minute Capacity in Liters Per Minute NOTE: Performance based on the following: PTFE fitted pump, flooded suction, water at ambient conditions. The use of other materials and varying hydraulic conditions may result in deviations in excess of 5%. 1 Model SPFP30 Food Processing

5 Materials Material Profile: CAUTION! Operating temperature limitations are as follows: Santoprene : Injection molded thermoplastic elastomer with no fabric layer. Long mechanical flex life. Excellent abrasion resistance. Virgin PTFE: (PFA/TFE) Chemically inert, virtually impervious. Very few chemicals are known to chemically react with PTFE; molten alkali metals, turbulent liquid or gaseous fluorine and a few fluoro-chemicals such as chlorine trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures. Operating Temperatures: Max. 275 F 135 C 220 F 104 C Min. - F - C -35 F -37 C Maximum and Minimum Temperatures are the limits for which these materials can be operated. Temperatures coupled with pressure affect the longevity of diaphragm pump components. Maximum life should not be expected at the extreme limits of the temperature ranges. Metals: Stainless Steel: Equal to or exceeding ASTM specification A743 CF-8M for corrosion resistant iron chromium, iron chromium nickel and nickel based alloy castings for general applicaitons. Commonly referred to as 316 Stainless Steel in the pump industry. 1: PUMP SPECS Model SPFP30 Food Processing 2

6 Dimensional Drawings Model SPFP30 Food Processing Dimensions in inches (metric dimensions in brackets). Dimensional Tolerance.125" (3mm) O.D. TRI- CLAMP DISCHARGE FLANGE : PUMP SPECS 1/2" NPT AIR INLET " NPT AIR EXHAUST O.D. TRI- CLAMP SUCTION FLANGE R BOTTOM VIEW 3 Model SPFP30 Food Processing

7 Principle of Pump Operation Air-Operated Double Diaphragm (AODD) pumps are powered by compressed air or nitrogen. The main directional (air) control valve 1 distributes compressed air to an air chamber, exerting uniform pressure over the inner surface of the diaphragm 2. At the same time, the exhausting air 3 from behind the opposite diaphragm is directed through the air valve assembly(s) to an exhaust port 4. As inner chamber pressure (P1) exceeds liquid chamber pressure (P2), the rod 5 connected diaphragms shift together creating discharge on one side and suction on the opposite side. The discharged and primed liquid s directions are controlled by the check valves (ball or flap)6 orientation. The pump primes as a result of the suction stroke. The suction stroke lowers the chamber pressure (P3) increasing the chamber volume. This results in a pressure differential necessary for atmospheric pressure (P4) to push the fluid through the suction piping and across the suction side check valve and into the outer fluid chamber 7. Suction (side) stroking also initiates the reciprocating (shifting, stroking or cycling) action of the pump. The suction diaphragm s movement is mechanically pulled through its stroke. The diaphragm s inner plate makes contact with an actuator plunger aligned to shift the pilot signaling valve. Once actuated, the pilot valve sends a pressure signal to the opposite end of the main directional air valve, redirecting the compressed air to the opposite inner chamber. 2: INSTAL & OP SUBMERGED ILLUSTRATION MUFFLER LIQUID LEVEL 1" DIAMETER AIR EXHAUST PIPING SUCTION LINE Pump can be submerged if the pump materials of construction are compatible with the liquid being pumped. The air exhaust must be piped above the liquid level. When the pumped product source is at a higher level than the pump (flooded suction condition), pipe the exhaust higher than the product source to prevent siphoning spills. Model SPFP30 Food Processing 4

8 Recommended Installation Guide Available Accessories: 1. Surge Suppressor 2. Filter/Regulator 3. Air Dryer Unregulated Air Supply to Surge Suppressor 1 Surge Suppressor Pressure Gauge Shut-Off Valve Note: Surge Suppressor and Piping must be supported after the flexible connection. Pipe Connection (Style Optional) Flexible Connector Discharge Check Valve 2: INSTAL & OP Muffler (Optional Piped Exhaust) Flexible Connector Vacuum Gauge Drain Port Flexible Connector 3 2 Shut-Off Valve Air Inlet Filter Regulator P/N: 020.V Suction Air Dryer Shut-Off Valve Drain Port Pipe Connection (Style Optional) Note: Pipe weight should not be supported by pump connections. CAUTION The air exhaust should be piped to an area for safe disposition of the product being pumped, in the event of a diaphragm failure. Installation And Start-Up Locate the pump as close to the product being pumped as possible. Keep the suction line length and number of fittings to a minimum. Do not reduce the suction line diameter. Air Supply Connect the pump air inlet to an air supply with sufficient capacity and pressure to achieve desired performance. A pressure regulating valve should be installed to insure air supply pressure does not exceed recommended limits. Air Valve Lubrication The air distribution system is designed to operate WITHOUT lubrication. This is the standard mode of operation. If lubrication is desired, install an air line lubricator set to deliver one drop of SAE 10 non-detergent oil for every 20 SCFM (9.4 liters/sec.) of air the pump consumes. Consult the Performance Curve to determine air consumption. Air Line Moisture Water in the compressed air supply may cause icing or freezing of the exhaust air, causing the pump to cycle erratically or stop operating. Water in the air supply can be reduced by using a point-of-use air dryer. Air Inlet And Priming To start the pump, slightly open the air shut-off valve. After the pump primes, the air valve can be opened to increase air flow as desired. If opening the valve increases cycling rate, but does not increase the rate of flow, cavitation has occurred. The valve should be closed slightly to obtain the most efficient air flow to pump flow ratio. 5 Model SPFP30 Food Processing

9 Troubleshooting Guide Symptom: Potential Cause(s): Recommendation(s): Pump Cycles Once Pump Will Not Operate / Cycle Pump Cycles and Will Not Prime or No Flow Pump Cycles Running Sluggish/Stalling, Flow Unsatisfactory Product Leaking Through Exhaust Premature Diaphragm Failure Deadhead (system pressure meets or exceeds air supply pressure). Air valve or intermediate gaskets installed incorrectly. Bent or missing actuator plunger. Pump is over lubricated. Lack of air (line size, PSI, CFM). Check air distribution system. Discharge line is blocked or clogged manifolds. Deadhead (system pressure meets or exceeds air supply pressure). Blocked air exhaust muffler. Pumped fluid in air exhaust muffler. Pump chamber is blocked. Cavitation on suction side. Check valve obstructed. Valve ball(s) not seating properly or sticking. Valve ball(s) missing (pushed into chamber or manifold). Valve ball(s)/seat(s) damaged or attacked by product. Check valve and/or seat is worn or needs adjusting. Suction line is blocked. Excessive suction lift. Suction side air leakage or air in product. Pumped fluid in air exhaust muffler. Over lubrication. Icing. Clogged manifolds. Deadhead (system pressure meets or exceeds air supply pressure). Cavitation on suction side. Lack of air (line size, PSI, CFM). Excessive suction lift. Air supply pressure or volume exceeds system hd. Undersized suction line. Restrictive or undersized air line. Suction side air leakage or air in product. Suction line is blocked. Pumped fluid in air exhaust muffler. Check valve obstructed. Check valve and/or seat is worn or needs adjusting. Entrained air or vapor lock in chamber(s). Diaphragm failure, or diaphragm plates loose. Diaphragm stretched around center hole or bolt holes. Cavitation. Excessive flooded suction pressure. Misapplication (chemical/physical incompatibility). Incorrect diaphragm plates or plates on backwards, installed incorrectly or worn. Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. (Does not apply to high pressure 2:1 units). Install gaskets with holes properly aligned. Remove pilot valve and inspect actuator plungers. Set lubricator on lowest possible setting or remove. Units are designed for lube free operation. Check the air line size and length, compressor capacity (HP vs. cfm required). Disassemble and inspect main air distribution valve, pilot valve and pilot valve actuators. Check for inadvertently closed discharge line valves. Clean discharge manifolds/piping. Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. (Does not apply to high pressure 2:1 units). Remove muffler screen, clean or de-ice, and re-install. Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. Disassemble and inspect wetted chambers. Remove or flush any obstructions. Check suction condition (move pump closer to product). Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. Clean out around valve ball cage and valve seat area. Replace valve ball or valve seat if damaged. Use heavier valve ball material. Worn valve ball or valve seat. Worn fingers in valve ball cage (replace part). Check Chemical Resistance Guide for compatibility. Check Chemical Resistance Guide for compatibility. Inspect check valves and seats for wear and proper setting. Replace if necessary. Remove or flush obstruction. Check and clear all suction screens or strainers. For lifts exceeding 20 of liquid, filling the chambers with liquid will prime the pump in most cases. Visually inspect all suction-side gaskets and pipe connections. Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. Set lubricator on lowest possible setting or remove. Units are designed for lube free operation. Remove muffler screen, de-ice, and re-install. Install a point of use air drier. Clean manifolds to allow proper air flow Increase the inlet air pressure to the pump. Pump is designed for 1:1 pressure ratio at zero flow. (Does not apply to high pressure 2:1 units). Check suction (move pump closer to product). Check the air line size, length, compressor capacity. For lifts exceeding 20 of liquid, filling the chambers with liquid will prime the pump in most cases. Decrease inlet air (press. and vol.) to the pump. Pump is cavitating the fluid by fast cycling. Meet or exceed pump connections. Install a larger air line and connection. Visually inspect all suction-side gaskets and pipe connections. Remove or flush obstruction. Check and clear all suction screens or strainers. Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. Inspect check valves and seats for wear and proper setting. Replace if necessary. Purge chambers through tapped chamber vent plugs. Purging the chambers of air can be dangerous. Replace diaphragms, check for damage and ensure diaphragm plates are tight. Check for excessive inlet pressure or air pressure. Consult Chemical Resistance Chart for compatibility with products, cleaners, temperature limitations and lubrication. Enlarge pipe diameter on suction side of pump. Move pump closer to product. Raise pump/place pump on top of tank to reduce inlet pressure. Install Back pressure device (Tech bulletin 41r). Add accumulation tank or pulsation dampener. Consult Chemical Resistance Chart for compatibility with products, cleaners, temperature limitations and lubrication. Check Operating Manual to check for correct part and installation. Ensure outer plates have not been worn to a sharp edge. Unbalanced Cycling Excessive suction lift. For lifts exceeding 20 of liquid, filling the chambers with liquid will prime the pump in most cases. Undersized suction line. Meet or exceed pump connections. Pumped fluid in air exhaust muffler. Suction side air leakage or air in product. Check valve obstructed. Check valve and/or seat is worn or needs adjusting. Entrained air or vapor lock in chamber(s). Disassemble pump chambers. Inspect for diaphragm rupture or loose diaphragm plate assembly. Visually inspect all suction-side gaskets and pipe connections. Disassemble the wet end of the pump and manually dislodge obstruction in the check valve pocket. Inspect check valves and seats for wear and proper setting. Replace if necessary. Purge chambers through tapped chamber vent plugs. 2: INSTAL & OP Model SPFP30 Food Processing 6

10 Composite Repair Parts Drawing - FDA Santoprene Fitted Torque to: 60 in-lbs Torque to: 275 in-lbs : EXP VIEW Torque to: 300 in-lbs WARREN RUPP INC. THIS IS A PROPRIETARY DOCUMENT. DO NOT REPRODUCE OR DISCLOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF WARREN RUPP INC. DESCRIPTION E3 FP RUBBER FITTED PUMP REV REVISION CHG DATE APP DATE ECN DRAWING NUMBER E3SJxxxx0C-ATEX REV 01 7 Model SPFP30 Food Processing

11 Composite Repair Parts List - FDA Santoprene Fitted Air Valve Assembly Item # Qty. Description Part Number Nickle Plated 1 1 Valve Body (includes items 2-11) Valve Body Valve Body Gasket Valve Sleeve O-ring Valve Spool Assembly (Includes items 7) Glyde Ring Assembly Stainless Steel Air Valve Screen End Cap Gasket End Cap Mounting Screws Center Section Assembly Item # Qty. Description Part Number Nickle Plated Stainless Steel 12 1 Center Block Assembly (Includes item 13) Main Shaft O-Ring Air Chamber Air Chamber Gasket Bolt Pilot Sleeve Assembly (include item 18) O-ring Retaining Ring Pilot Spool Assembly (Includes item 21) O-ring Muffler Diaphragm Assembly / Elastomers Part Number Item # Qty. Description SPFP30NPS SPFP30SSS FDA Santoprene FDA Santoprene 23 1 Main Shaft Diaphragm Outer Diaphragm Plate Inner Diaphragm Plate Bolt Washer Bumper Washer Back-Up Washer Valve Seat Valve Ball Wet End Assembly Item # Qty. Description Part Number 33 2 Water Chamber Large Clamp Half 35 4 Bolt 36 4 Large Wing Nut 37 1 Discharge Manifold 38 1 Suction Manifold 39 8 Small Clamp Half 8 Bolt 41 8 Small Wing Nut : EXP VIEW Model SPFP30 Food Processing 8

12 Composite Repair Parts Drawing - PTFE Fitted Torque to: 480 in-lbs Torque to: 480 in-lbs Torque to: 60 in-lbs 7 9 BONDED DIAPHRAGM ASSEMBLEY BONDED DIAPHRAGM ASSEMBLEY Torque to: 480 in-lbs : EXP VIEW Torque to: 275 in-lbs WARREN RUPP INC. THIS IS A PROPRIETARY DOCUMENT. DO NOT REPRODUCE OR DISCLOSE WITHOUT THE EXPRESS WRITTEN PERMISSION OF WARREN RUPP INC. DESCRIPTION E3 FP PTFE FITTED PUMP REV REVISION CHG DATE APP DATE ECN DRAWING NUMBER E3Sx5xxx0C-FP-ATEX REV 01 9 Model SPFP30 Food Processing

13 Composite Repair Parts List - PTFE Fitted Air Valve Assembly Item # Qty. Description Part Number Nickle Plated 1 1 Valve Body (Includes items 2-11) Valve Body Valve Body Gasket Valve Sleeve O-ring Valve Spool Assembly (Includes items 7) Glyde Ring Assembly Notes: In addition to this seat, (4) O-Rings are needed. Stainless Steel Air Valve Screen End Cap Gasket End Cap Mounting Screws Center Section Assembly Item # Qty. Description Part Number Nickle Plated Stainless Steel 12 1 Center Block Assembly (Includes item 13) Main Shaft O-Ring Air Chamber Air Chamber Gasket Bolt Pilot Sleeve Assembly (Include item 18) O-ring Retaining Ring Pilot Spool Assembly (Includes item 21) O-ring Muffler Diaphragm Assembly / Elastomers Item # Qty. Description 23 1 Main Shaft 24 2 Diaphragm 25 1 Back Up Diaphragm 26 2 Outer Diaphragm Plate 27 2 Inner Diaphragm Plate 28 2 Bumper Washer 29 2 Back-Up Washer 30 4 Valve Seat 31 4 Valve Ball Part Number Nickle Plated Air End PTFE Two Piece (See Note 1) Wet End Assembly Item # Qty. Description Part Number 32 2 Water Chamber Large Clamp Half Bolt Large Wing Nut Discharge Manifold Suction Manifold Small Clamp Half Bolt Small Wing Nut Diaphragm Seal Tape Kit (Not pictured) : EXP VIEW Model SPFP30 Food Processing 10

14 DECLARATION OF CONFORMITY DECLARATION DE CONFORMITE DECLARACION DE CONFORMIDAD ERKLÄRUNG BEZÜGLICH EINHALTUNG DER VORSCHRIFTEN DICHIARAZIONE DI CONFORMITÀ CONFORMITEITSVERKLARING DEKLARATION OM ÖVERENSSTÄMMELSE EF-OVERENSSTEMMELSESERKLÆRING VAATIMUSTENMUKAISUUSVAKUUTUS SAMSVARSERKLÄRING DECLARAÇAO DE CONFORMIDADE MANUFACTURED BY: FABRIQUE PAR: FABRICADA POR: HERGESTELLT VON: FABBRICATO DA: VERVAARDIGD DOOR: TILLVERKAD AV: FABRIKANT: VALMISTAJA: PRODUSENT: FABRICANTE: STANDARD PUMP, INC Satellite Blvd., Suite D Duluth, GA USA Tel: PUMP MODEL SERIES: SPFP05, SPFP10, SPFP15, SPFP20, SPFP30, SPSN15, SPSN20, SP3A15, SP3A20 This product complies with the following European Community Directives: 2006/42/EC Ce produit est conforme aux directives de la Communauté européenne suivantes: Este producto cumple con las siguientes Directrices de la Comunidad Europea: on Machinery, according Dieses produkt erfüllt die folgenden Vorschriften der Europäischen Gemeinschaft: to Annex VIII Questo prodotto è conforme alle seguenti direttive CEE: Dir produkt voldoet aan de volgende EG-richtlijnen: Denna produkt överensstämmer med följande EU direktiv: Standard Pump, Inc., erklærer herved som fabrikant, at ovennævnte produkt er i overensstemmelse med bestemmelserne i Direkktive: Tämä tuote täyttää seuraavien EC Direktiivien vaatimukstet: Dette produkt oppfyller kravene til følgende EC Direktiver: Este produto está de acordo com as seguintes Directivas comunitárias: This product has used the following harmonized standards to verify conformance: Ce materiel est fabriqué selon les normes harmonisées suivantes, afin d en garantir la conformité: Este producto cumple con las siquientes directrices de la comunidad europa: Dieses produkt ist nach folgenden harmonisierten standards gefertigtworden, die übereinstimmung wird bestätigt: Questo prodotto ha utilizzato i seguenti standards per verificare la conformita : De volgende geharmoniseerde normen werden gehanteerd om de conformiteit van dit produkt te garanderen: För denna produkt har följande harmoniserande standarder använts för att bekräfta överensstämmelse: Harmoniserede standarder, der er benyttet: Tässä tuotteessa on sovellettu seuraavia yhdenmukaistettuja standardeja: Dette produkt er produsert i overenstemmelse med fløgende harmoniserte standarder: Este produto utilizou os seguintes padrões harmonizados para varificar conformidade: EN809:1998+ A1:2009 AUTHORIZED / APPROVED BY: Approuve par: Aprobado por: Genehmigt von: approvato da: Goedgekeurd door: Underskrift: Valtuutettuna: Bemyndiget av: Autorizado Por: Chris Murphy Director of Operations DATE: July 20, 2012 FECHA: DATUM: DATA: DATO: PÄIVÄYS: 10/13/2015 REV 08 VMQR 044FM

15 DECLARATION OF CONFORMITY WITH ATEX 95 DIRECTIVE Date of Issue: 10 May 2014 Technical File No.: /MER Quality System Registration No: ISO Directive: Conforming Apparatus: Hazardous Location Applied: 94/9/EC 23 March 1994 Annex VIII Air-Operated Metal Double Diaphragm Pumps for Use In Potentially Explosive Atmospheres II 2 G c T5 II 2 D c T100 C T5 fluids up to 95 C Manufacturer: Standard Pump, Inc Satellite Blvd., Suite D Duluth, GA USA On File With: DEKRA Certification B.V. (0344) Meander MJ Arnhem The Netherlands Harmonized Standards Applied: BS EN :2009 Non-Electrical Equipment Potentially Explosive Atmospheres-Part 1 Basic Methods and Requirements EN :2011 Non-Electrical Equipment for Potentially Explosive Atmospheres-Part 5 Protection by Constructional Safety Equipment: SPFP20, SPFP30, SPSN20, SPFP15, SPSN15 We hereby certify that the above apparatuses described above conforms with the protection requirements of Council Directive 94/9/EC of 23 March 1994 Annex VIII on the approximation of the laws of the Member States Concerning Equipment and Protective Systems Intended for use in Potentially Explosive Atmospheres DATE/OF REVISION/TITLE: Chris Murphy 13 October 2015 Director of Operations

16 Declaration of Conformity Manufacturer: Standard Pump, Inc Satellite Blvd., Suite D, Duluth, GA 30097, USA certifies that Air-Operated Double Diaphragm Food Processing and Sanitary Pump Models comply with the European Community Regulation 1935/2004/EC for Food Contact Materials. Food Processing Pump Models: SPFP05PPS SPFP30NPS SPFP10PPS SPFP30SSS SPFP15NPS SPFP05PPP SPFP20NPS SPFP10PPP SPFP20SSS SPFP15NPP SPFP30NPT SPFP20NPP SPFP30SST SPFP20SSP Sanitary Pump Models: SPSN15NPS SPSN20NPS SPSN20SSS SPSN15NPP SPSN20NPP SPSN20SSP Signature of authorized person September 11, 2013 Date of issue Chris Murphy Printed name of authorized person Revision Level: B Director of Operations Title October 13, 2015 Date of revision

Standard Pump SPFP15. Service & Operating Manual. 1 1/2" Food Processing. Original Instructions. SPFP15 Models SPFP15NPT SPFP15NPS SPFP15NPP

Standard Pump SPFP15. Service & Operating Manual. 1 1/2 Food Processing. Original Instructions. SPFP15 Models SPFP15NPT SPFP15NPS SPFP15NPP Standard Pump Service & Operating Manual Original Instructions 1 1/" Food Processing SPFP15 Models SPFP15NPT SPFP15NPS SPFP15NPP SPFP15 STANDARD PUMP, INC 16 Satellite Blvd Suite D. Duluth, Ga. 097 Phone:

More information

Standard Pump. Service & Operating Manual. 2" Food Processing with Metallic Center Section SPFP20. Original Instructions

Standard Pump. Service & Operating Manual. 2 Food Processing with Metallic Center Section SPFP20. Original Instructions Standard Pump Service & Operating Manual Original Instructions 2" Food Processing with Metallic Center Section SPFP20 SPFP20 Models SPFP20NPT SPFP20NPS SPFP20SSS SPFP20SST SPFP20NPP SPFP20SSP STANDARD

More information

1 1/2 Elima-Matic Bolted Non-Metallic with Metallic Center Section

1 1/2 Elima-Matic Bolted Non-Metallic with Metallic Center Section 1 1/2 Elima-Matic Bolted Non-Metallic with Metallic Center Section Performance 9 7 6 2 2 16 1 Meters Feet 9 7 6 4 2 1 BAR Discharge Head in PSI 1 1 6 6 Capacity Per Stroke,.24 Gal. (.91 L) AIR CONSUMPTION

More information

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS OPERATION MANUAL 2 METALLIC PUMP (BOLTED) PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF50 AIR-OPERATED DOUBLE DIAPHRAGM PUMPS ALUMINUM Models 316 S.S. Models A JDA Global Company CAUTIONS - READ FIRST CAUTION:

More information

Model G30 Metallic Design Level 1

Model G30 Metallic Design Level 1 SERVICE & OPERATING MANUAL Model G30 Metallic Design Level 1 Natural Gas-Operated Diaphragm Pumps CE II 2GD T5 U.S. Patent # 5,996,627; 6,241,487 Other U.S. Patents Applied for Table of Contents Engineering

More information

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL

AIR-OPERATED DOUBLE DIAPHRAGM PUMP USER S MANUAL 00, 0, 000 00, 000, 00 A. TECHNICAL INFORMATION Model 00 Inlet/Outlet " Air Inlet /" 0 / 000 /" /" 00 /" /" 000 /" /" 00 /" /" Flow Rate GPM/ 0LPM GPM/ 0LPM GPM/ LPM GPM/ LPM GPM/ 0LPM GPM/ 0LPM Maximum

More information

Model G1F Metallic Design Level 1

Model G1F Metallic Design Level 1 SERVICE & OPERATING MANUAL Model G1F Metallic Design Level 1 Natural Gas-Operated Diaphragm Pumps CE II 2GD T5 U.S. Patent # 5,996,627; 6,241,487 Other U.S. Patents Applied for Table of Contents Engineering

More information

AIR OPERATED DOUBLE DIAPHRAGM PUMP

AIR OPERATED DOUBLE DIAPHRAGM PUMP SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B15 & X15 Hygienic Series Inc. Lube Free This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 Table

More information

B25 & X25 SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP. Hygienic Series Inc. Lube Free Models. II 2 GD c.

B25 & X25 SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP. Hygienic Series Inc. Lube Free Models. II 2 GD c. SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B25 & X25 Hygienic Series Inc. Lube Free Models This pump is Atex approved for use in potentially explosive atmospheres Group II category 2

More information

B50 & X50 AIR OPERATED DOUBLE DIAPHRAGM PUMP. Hygienic B5002 B5005 Series Lube Free. II 2 GD c. Table of Contents

B50 & X50 AIR OPERATED DOUBLE DIAPHRAGM PUMP. Hygienic B5002 B5005 Series Lube Free. II 2 GD c. Table of Contents SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B50 & X50 Hygienic B5002 B5005 Series Lube Free This pump is Atex approved for use in potentially explosive atmospheres Group II category 2

More information

Model G05 Metallic Design Level 1

Model G05 Metallic Design Level 1 SERVICE & OPERATING MANUAL II 2GD T5 Model G05 Metallic Design Level 1 Natural Gas-Operated Diaphragm Pumps CE U.S. Patent # 5,996,627; 6,241,487 Other U.S. Patents Applied for Table of Contents Engineering

More information

SERVICE & OPERATING MANUAL

SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B06 AIR OPERATED DOUBLE DIAPHRAGM PUMP Non-Metallic 04 Series Table of Contents Service / Maintenance Log 2 Performance Curve 3 Dimensions

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

SERVICE & OPERATING MANUAL

SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B06 & X06 Metallic Models 04 Series This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 Table of Contents

More information

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump. WIL E-10 Replaces WIL E-09

EOM PX1500. Engineering Operation & Maintenance. Advanced Series Metal Pump.  WIL E-10 Replaces WIL E-09 EOM Engineering Operation & Maintenance PX1500 Advanced Series Metal Pump W h e r e I n n o v a t i o n F l o w s. www.wildenpump.com WIL-11230-E-10 Replaces WIL-11230-E-09 TABLE OF CONTENTS SECTION 1

More information

OPERATOR S MANUAL

OPERATOR S MANUAL OPERATOR S MANUAL 1604619 INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 11-1-13 REVISED: 3-03-14 (REV. B) 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) 1604628 READ THIS MANUAL CAREFULLY BEFORE

More information

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED. A JDA Global Company

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED. A JDA Global Company OPERATION MANUAL 1.5 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF40 CLAMPED AIR-OPERATED DOUBLE DIAPHRAGM PUMPS A JDA Global Company CAUTIONS - READ FIRST CAUTION: Do not apply compressed

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

2 I All-Flo Pump Co.

2 I All-Flo Pump Co. 2 I All-Flo Pump Co. 3I All-Flo Pump Co. Model Designation Matrix PRODUCT SERIES PUMP SIZE FLUID CONNECTI INTERM INNER CHAM ON TYPE FLUID C HAMBER MANIFOLDS EDI A TE/ BER O-RINGS VAL VE SEAT VALVE/BAL

More information

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-07 REPLACES WIL E-06 P400/PX400 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11210-E-07 REPLACES WIL-11210-E-06 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER

SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SAFETY MANUAL FOR FLAMMABLE PRODUCT TRANSFER SUPPLIMENT TO eom IMPORTANT READ THIS MANUAL BEFORE PRODUCT INSTALLATION, OPERATION, INSPECTION & MAINTENANCE Tougher and more rigid guidelines are being established

More information

SERVICE & OPERATING MANUAL

SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B15 & X15 Moulded Non-Metallic Series This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 Table of

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

P800/PX800. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11 P800/PX800 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11220-E-12 REPLACES WIL-11220-E-11 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

Pressure Dump Valve Service Kit for Series 2300 Units

Pressure Dump Valve Service Kit for Series 2300 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 00 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00 applicator tanks when the unit

More information

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11

P400/PX400. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-12 REPLACES WIL E-11 P400/PX400 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11210-E-12 REPLACES WIL-11210-E-11 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

4400 TwinHybrid Gas Seal

4400 TwinHybrid Gas Seal 4400 TwinHybrid Gas Seal EQUIPMENT PREPARATION MECHANICAL SEAL INSTALLATION INSTRUCTIONS 1 2 200.005" 0,13 mm 125 µ" 3,2 µm R a 3 4 32 µ" 0,8 µm R a 1000 ±.002" 0,05mm CAUTIONS These instructions are general

More information

PX1500. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance. WIL E-02 Replaces WIL E-01

PX1500. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance. WIL E-02 Replaces WIL E-01 PX1500 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11230-E-02 Replaces WIL-11230-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

SERVICE & OPERATING MANUAL

SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B50 & X50 Moulded Non-Metallic Series This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 Table of

More information

LRS(H)4 Pressure-Reducing Regulator User Manual

LRS(H)4 Pressure-Reducing Regulator User Manual LRS(H)4 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be considered

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.

More information

ACCU-PULSE Installation and Operation Instructions

ACCU-PULSE Installation and Operation Instructions ACCU-PULSE Installation and Operation Instructions Pump Discharge Installation: Chargeable Models Step 1: Mounting Position Mount ACCU-PULSE as close to the pump discharge as possible to absorb the pulse

More information

B25 & X25 SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP Series 1 Models. II 2 GD c

B25 & X25 SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP Series 1 Models. II 2 GD c SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B25 & X25 25 05 Series 1 Models This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 This Manual covers

More information

RD(H)20/25 Pressure-Reducing Regulator User Manual

RD(H)20/25 Pressure-Reducing Regulator User Manual RD(H)20/25 Pressure-Reducing Regulator User Manual Read the complete manual before installing and using the regulator. 2 Safe Product Selection When selecting a product, the total system design must be

More information

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator.

PRS(TC)4,8 USER MANUAL. Read the complete manual before installing and using the regulator. PRS(TC)4,8 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

2 I All-Flo Pump Co.

2 I All-Flo Pump Co. 2 I All-Flo Pump Co. 3I All-Flo Pump Co. Model Designation Matrix Pump Dimensions A B C D F H I J K L P300 18.90" 22.83" 31.50" 3.94" 15.28" 27.17" 1.57" 2.95" 15.55" 19.49" (480 mm) (580 mm) (800 mm)

More information

TECHNICAL DATA. Page 1 of 12

TECHNICAL DATA. Page 1 of 12 Page 1 of 12 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking Model H or J Flow Control

More information

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts

More information

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009

TECHNICAL DATA. Pressure Regulation 531a. April 24, 2009 April 24, 29 Pressure Regulation 531a 1. DESCRIPTION The Viking Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator.

RS(H)10,15 USER MANUAL. Read the complete manual before installing and using the regulator. RS(H)10,15 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to

More information

Model G20F. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP

Model G20F. SERVICE & OPERATING MANUAL Original Instructions. Heavy Duty Flap Valve Design Level 1. Certified Quality 1: PUMP SPECS 2: INSTAL & OP SERVICE & OPERATING MANUAL Original Instructions Certified Quality Model G20F Heavy Duty Flap Valve Design Level 1 1: PUMP SPECS 2: INSTAL & OP ISO 9001 Certified ISO 14001 Certified Certified to CSA Technical

More information

AIR OPERATED DOUBLE DIAPHRAGM PUMP

AIR OPERATED DOUBLE DIAPHRAGM PUMP SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP Model E02 Metallic Model X02 Metallic (ATEX Compliant) Design Level 4 Table of Contents Safety Information...2 Grounding the Pump...2 Dimensions...3

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 348a 1. Description Viking supervised Surefire Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated Viking G-6000P Valve comes complete

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL

ATD LB PRESSURE BLASTER INSTRUCTION MANUAL ATD-8402 90LB PRESSURE BLASTER INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS SAFETY INSTRUCTIONS FOR SANDBLASTER 1. Before opening the tank release the air pressure on the sand tank. To do this, turn off

More information

TECHNICAL DATA CAUTION

TECHNICAL DATA CAUTION Page 1 of 12 1. DESCRIPTION The Viking Model C-2 Pilot Pressure Regulating Valve is a direct-acting, single-seated, spring-loaded diaphragm valve. When installed as a pilot regulating valve on a Viking

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 331a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 347a 1. Description Viking supervised Double-Interlocked Electric/Pneumatic Release Preaction Systems utilize the Viking G-6000P Valve. The small profile, lightweight, pilot operated

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S January 6, 2012 Preaction 333a 1. Description Viking supervised Surefire Preaction Systems Utilize the Viking G-3000P Valve. The small profile, lightweight, pilot-operated Viking G-3000P Valve comes complete

More information

EOM PX4. Engineering Operation & Maintenance. Saniflo Hygienic Series Metal Pumps. WIL E-04 TO REPLACE WIL E-03

EOM PX4. Engineering Operation & Maintenance. Saniflo Hygienic Series Metal Pumps.  WIL E-04 TO REPLACE WIL E-03 EOM Engineering Operation & Maintenance PX4 Saniflo Hygienic Series Metal Pumps W h e r e I n n o v a t i o n F l o w s www.wildenpump.com WIL-12300-E-04 TO REPLACE WIL-12300-E-03 TABLE OF CONTENTS SECTION

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL 3200-300 INSTALLATION, OPERATION AND MAINTENANCE MANUAL PLEASE READ CAREFULLY YOUR WARRANTY MAY BE VOID IF INSTRUCTIONS ARE NOT FOLLOWED Note: when ordering parts give pump model and serial number Cornell

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Preaction 346a 1. Description The 6 Model G-6000P Electric Release Preaction System Riser Assembly can be used as a Single Interlock Preaction System with Electric Release, or as a Double Interlock Preaction

More information

Dean Pump Self-Priming Chemical Process Pumps

Dean Pump Self-Priming Chemical Process Pumps Bulletin C 1.2.34.7 Dean Pump Self-Priming Chemical Process Pumps php Series HEAD CAPACITY RANGE CHARTS php Self Primer - 2 Pole 3500 RPM 500 CAPACITY M 3 /HR 2900 RPM 50 HERTZ 25 50 75 125 150 400 TOTAL

More information

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A

End Connection. Thread x Thread N/A N/A N/A N/A Flange x Flange N/A Worldwide Contacts www.tyco-fire.com Model RV-1 Pressure Relief Valve, Pilot-Operated, Globe and Angle Body Styles General Description Valves, through inch (DN50 through DN00), are factory assembled and

More information

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator.

LRS(H)4 USER MANUAL. Read the complete manual before installing and using the regulator. LRS(H)4 USER MANUAL Read the complete manual before installing and using the regulator. WARNING INCORRECT OR IMPROPER USE OF THIS PRODUCT CAN CAUSE SERIOUS PERSONAL INJURY AND PROPERTY DAMAGE. Due to the

More information

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven

4 IN. BALL LAUNCHER Engine Mounted / PTO Driven 4 IN. BALL LAUNCHER Engine Mounted / PTO Driven OPERATOR S PARTS and MAINTENANCE MANUAL 2006 EDITION BL-MAN-4EN Creation Revision date: 10MAR06 date: by: Ivon LeBlanc by: Table of Contents Table of Contents...

More information

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER

FAST & FLEXIBLE EXPERTISE 100% ORDER FULFILLMENT LOW COST PROVIDER FAST & FLEXIBLE JDA Global LLC (EST. 0) serves as the world s largest & most experienced after-market diaphragm pump products provider. We leverage our deeply embedded industry knowledge each day to bring

More information

EOM. PX2 Saniflo Hygienic Series Metal Pumps. Engineering Operation & Maintenance. WIL E-06 REPLACES WIL E-05

EOM. PX2 Saniflo Hygienic Series Metal Pumps. Engineering Operation & Maintenance.  WIL E-06 REPLACES WIL E-05 EOM Engineering Operation & Maintenance PX2 Saniflo Hygienic Series Metal Pumps W h e r e I n n o v a t i o n F l o w s www.wildenpump.com WIL-12330-E-06 REPLACES WIL-12330-E-05 TABLE OF CONTENTS SECTION

More information

3/8" Dr. Air Butterfly Impact Wrench

3/8 Dr. Air Butterfly Impact Wrench 8192106 3/8" Dr. Air Butterfly Impact Wrench Owner s Manual Read and understand all instructions before use. Retain this manual for future reference. Specifications Construction: Polished aluminum and

More information

Models: C62/63/64-A/D

Models: C62/63/64-A/D Installation & Service C62-991-24A3 Models: C62/63/64-A/D Diaphragm Bypass Pressure Regulating Valves IMPORTANT Record your pump model number and serial number here for easy reference: Model No. Serial

More information

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS

AIR STAPLER. MODEL: CSG3KC Part No OPERATING & MAINTENANCE INSTRUCTIONS AIR STAPLER MODEL: CSG3KC Part No. 3110380 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.4 cfm

More information

Model Air Caddy Orig TABLE OF CONTENTS

Model Air Caddy Orig TABLE OF CONTENTS 92-0919 Orig. 020201 Model 75-0114 Air Caddy TABLE OF CONTENTS CUSTOMER MESSAGE Inside Front Cover SAFETY PRECAUTIONS 3 GENERAL DESCRIPTION 6 SPECIFICATIONS 7 MAINTENANCE 9 INSTALLATION AND OPERATION 11

More information

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL

MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL MODEL 200 KNIFE GATE VALVES INSTALLATION & MAINTENANCE MANUAL Index 1. List of components / General arrangement 2. Description 3. Handling 4. Installation 5. Actuators / Operation 6. Maintenance a. Changing

More information

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator.

RHPS Series RD(H)F40 User Manual. Read the complete manual before installing and using the regulator. RHPS Series RD(H)F40 User Manual Read the complete manual before installing and using the regulator. 2 WARNING Before removing a regulator from the system for service, you must depressurize system purge

More information

SERVICE & OPERATING MANUAL

SERVICE & OPERATING MANUAL SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B50 & X50 Full Flow High Pressure Series This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 Table

More information

P4/PX4. Original Series METAL Pumps. Simplify your process. Engineering Operation & Maintenance. WIL E-07 Replaces WIL E-06

P4/PX4. Original Series METAL Pumps. Simplify your process. Engineering Operation & Maintenance. WIL E-07 Replaces WIL E-06 P4/PX4 Original Series METAL Pumps Engineering Operation & Maintenance Simplify your process WIL-10310-E-07 Replaces WIL-10310-E-06 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

EOM PX2. Engineering Operation & Maintenance. Saniflo Hygienic Series. WIL E-05 TO REPLACE WIL E-04

EOM PX2. Engineering Operation & Maintenance. Saniflo Hygienic Series.  WIL E-05 TO REPLACE WIL E-04 EOM Engineering Operation & Maintenance PX2 Saniflo Hygienic Series Metal Pumps W h e r e I n n o v a t i o n F l o w s www.wildenpump.com WIL-12330-E-05 TO REPLACE WIL-12330-E-04 TABLE OF CONTENTS SECTION

More information

DIAPHRAGM PUMP MODEL PDM 1-175

DIAPHRAGM PUMP MODEL PDM 1-175 INSTRUCTION MANUAL DIAPHRAGM PUMP MODEL PDM 1-175 Manual : 0704 573.034.112 Date : 18/04/07 - Supersede : 17/06/02 - Modif. : + ATEX KREMLIN REXSON - 150, avenue de Stalingrad - 93245 STAINS Cedex - FRANCE

More information

Pneumatic Powered - Plunger Pumps

Pneumatic Powered - Plunger Pumps Models 42/62/82 D Series P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pumps Suggested Installation & Operating Instructions

More information

Pressure Dump Valve Service Kit for Series 3000 Units

Pressure Dump Valve Service Kit for Series 3000 Units Instruction Sheet Pressure Dump Valve Service Kit for Series 000 Units. Overview The Nordson pressure dump valve is used to relieve hydraulic pressure instantly in Series 00, 400, 500, and 700 applicator

More information

EOM PX15. Engineering Operation & Maintenance. Saniflo Hygienic Series Metal Pumps. WIL E-04 TO REPLACE WIL E-03

EOM PX15. Engineering Operation & Maintenance. Saniflo Hygienic Series Metal Pumps.  WIL E-04 TO REPLACE WIL E-03 EOM Engineering Operation & Maintenance PX15 Saniflo Hygienic Series Metal Pumps W h e r e I n n o v a t i o n F l o w s www.wildenpump.com WIL-12320-E-04 TO REPLACE WIL-12320-E-03 TABLE OF CONTENTS SECTION

More information

Tank Blanketing Pressure Regulators RHPS Series

Tank Blanketing Pressure Regulators RHPS Series www.swagelok.com Tank Blanketing Pressure Regulators RHPS Series Types: pressure reducing and vapor recovery 16L stainless steel construction 1/2, 1, and 2 in. end connections Working pressures up to 22

More information

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301

THE HF-300 SERIES. Operating and Service Manual. Series includes all variants of HF-300/301 THE HF-300 SERIES Operating and Service Manual Series includes all variants of HF-300/301 Issue A July 2015 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 3.1. Spring Loaded...

More information

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50)

TECHNICAL DATA. Page 1 of 8. model f /2 (dn40) & 2 (dn50) Page 1 of 8 1. DESCRIPTION The Viking Model F-1 Deluge Valve is a quick opening, differential diaphragm, flood valve with one moving mechanism. The Deluge Valve is used to control water flow in Deluge

More information

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE

TECHNICAL DATA DELUGE VALVE, MODEL F-1 STRAIGHT THROUGH STYLE Page 1 of 10 1. DESCRIPTION The Viking Model F-1 Deluge Valve is a quick opening, differential diaphragm and flood valve with one moving mechanism. The Deluge Valve is used to control water flow in Deluge

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 46501 and 465010 Hydrostatic Test Pumps 46501 DIMENSIONS: WEIGHT: PUMP: ENGINE: CONTROL: GAUGE: DISCHARGE HOSE: INLET HOSE: 28 (70cm) L x 24 (60cm) W x 35 (87.5cm) H 136 lbs.

More information

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1

TECHNICAL DATA MAINTENANCE AIR COMPRESSOR MODEL G-1 Dry 131h 1. DESCRIPTION The Viking Model G-1 Maintenance Air Compressor is an electric motor-driven, aircooled, single-stage, oil-less compressor. The unit is equipped with a check valve and provides a

More information

Suggested Installation & Operating Instructions for Sidewinder Pumps

Suggested Installation & Operating Instructions for Sidewinder Pumps Model 164 C P.O. Box 80769 Lafayette, LA 70598-0769 (337) 235-9838 FAX (337) 235-9852 www.sidewinderpumps.com Pneumatic Powered - Plunger Pump Suggested Installation & Operating Instructions for Sidewinder

More information

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM.

Installation Operation Maintenance. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow IOM. Bermad Level Control Valve with Modulating Horizontal Float Pilot valve One Way Flow Model: FP 450-80 Installation Operation Maintenance PAGE 1 OF 5 1. Safety First BERMAD believes that the safety of personnel

More information

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401

THE MF-400 SERIES. Operating and Service Manual. Series includes all variants of MF-400/401 THE MF-400 SERIES Operating and Service Manual Series includes all variants of MF-400/401 Issue A October 2013 1 TABLE OF CONTENTS 1. Description... 3 2. Installation... 3 3. Operation... 4 4. Special

More information

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS

HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS HAYWARD FLOW CONTROL Series PBV Back Pressure Valve and Series RPV Pressure Relief Valve INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Page 1 of 20 Page 2 of 20 TABLE OF CONTENTS Safety Warnings

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

Booster Regulator/Air Tank

Booster Regulator/Air Tank Booster Regulator/Air Tank Increase factory air pressure by up to 4 times! Air-only operation requires no power supply, reduces heat generation, and Boost pressure allows easy installation. NEW Renewed

More information

Operation Manual Piston Sensed Gas Pressure Regulators

Operation Manual Piston Sensed Gas Pressure Regulators 687 Technology Way Napa, CA 94558 Phone: (707) 259-0102 FAX: (707) 259-0117 www.aptech-online.com Operation Manual Piston Sensed Gas Pressure Regulators (Models KT9, KT10, Welded KT10, KT12) Table of Contents:

More information

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List 1 Liter High- Pressure Gel Coat Spray Gun 134-A Usage Instructions & Parts List www.fibreglast.com 1.800.821.3283 385 Carr Drive Brookville, OH 45309 Operating Instructions & Suggestions This is a high

More information

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia

Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia Instruction Manual - Diaframless TM Ejector Chlorine, Sulfur Dioxide and Ammonia - 1-122.6010.6 These instructions describe the installation, operation and maintenance of the subject equipment. Failure

More information

AIR STAPLER MODEL: CSG1C Part No

AIR STAPLER MODEL: CSG1C Part No AIR STAPLER MODEL: CSG1C Part No. 3110375 0506 OPERATING & MAINTENANCE INSTRUCTIONS SPECIFICATIONS Min. Hose Size (ID)... 6mm (1/4 ) Air Inlet Connector... 10mm Quick Fit Ave. Air Consumption... 0.27 cfm

More information

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP

A050-1/2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 - /2 INCH AIR OPERATED double DIAPHRAGM PUMP A050 /2 Pump /2 Aluminum NPT or BSP Connections Zinc Plated Hardware Non-Metallic Muffler Suction Right / Discharge Right Standard Porting SPECIFICATIONS

More information

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual

Bray/ VAAS O-Ported Series Knife Gate Valve 770/780 Series Operation and Maintenance Manual Bray/ VAAS Knife Gate Valve 770/780 Series Operations and Maintenance Manual Table of Contents Definition of Terms 1 Safety Instructions 1 Introduction 2 Unpacking 2 Storage 2 Installation 2 Commissioning

More information

T1-Titanium HVLP Siphon Feed Spray Gun

T1-Titanium HVLP Siphon Feed Spray Gun T1-Titanium HVLP Siphon Feed Spray Gun THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly.

Components for air preparation and pressure adjustment. OUT port position ( ) connected Rear side. of IN port. Air tank. directly. Components preparation and pressure adjustment ABP Overview ABP is a component that enables boosting by s only up to twice primary pressure (.0MPa max.) in combination with using air tank but not using

More information

PX1510. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-01

PX1510. Advanced Series METAL Pumps. Advance your process. Engineering Operation & Maintenance WIL E-01 PX1510 Advanced Series METAL Pumps Engineering Operation & Maintenance Advance your process WIL-11270-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!..............................................1

More information

P400/PX400. Advanced Series PLASTIC Pumps. Advance your process. Engineering Operation & Maintenance WIL E-02 TO REPLACE WIL E-01

P400/PX400. Advanced Series PLASTIC Pumps. Advance your process. Engineering Operation & Maintenance WIL E-02 TO REPLACE WIL E-01 P400/PX400 Advanced Series PLASTIC Pumps Engineering Operation & Maintenance Advance your process WIL-11240-E-02 TO REPLACE WIL-11240-E-01 TABLE OF CONTENTS SECTION 1 CAUTIONS READ FIRST!.............................................1

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions

KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions 4059051/3 IM-P405-48 EMM Issue 3 KBV21i and KBV40i Key Operated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4.

More information