1 Esco Technologies, Inc Turnpike Drive, Units Hatboro, PA 19040, USA Toll-Free USA and Canada Tel Fax us.escoglobal.com User Manual Esco Micro Pte. Ltd. 21 Changi South Street 1 Singapore Tel Fax mail@escoglobal.com

2 Copyright Information Copyright 2011 Esco Micro Pte. Ltd. All rights reserved. The information contained in this manual and the accompanying product is copyrighted and all rights are reserved by Esco. Esco reserves the right to make periodic minor design changes without obligation to notify any person or entity of such change. Sentinel are registered trademarks of Esco. Material in this manual is provided for informational purposes only. The contents and the product described in this manual (including any appendix, addendum, attachment or inclusion), are subject to change without notice. Esco makes no representations or warranties as to the accuracy of the information contained in this manual. In no event shall Esco be held liable for any damages, direct or consequential, arising out of or related to the use of this manual.

3 i i iii v v v v v vii Table of Contents Warranty Terms and Conditions Introduction 1. Products Covered 2. Safety Warning 3. Limitation of Liability 4. European Union Directives on WEEE and RoHS Declaration of Conformity INTRODUCTORY PAGES 1 Chapter 1 -Product Information About Esco Formalin Vaporizer Labels Quick View USER SECTION 3 Chapter 2 -Control System Sentinel Control System Menu Options Before Decontamination Process Start After Decontamination Process Start 7 Chapter 3 - Decontamination Process Formalin/Paraformaldehyde Decontamination Common Equipment Used in Decontamination Common Equipment Appropriate PPE Common Apparatus Preparation Steps Recommended Decontamination Sealing Method For Unit without Ducting For Unit with Ducting Decontamination Process Formalin Ammonia Combination Paraformaldehyde Ammonium Bicarbonate Combination Completion Steps Decontamination Validation Procedure (optional) APPENDIX Formalin Vaporizer

4 ii

5 iii Esco products come with either a 1, 2 or 3 year limited warranty, depending on the product purchased, beginning on the date of shipment from any Esco international warehousing location. To determine which warranty applies to your product, refer to the appendix below. Esco's limited warranty covers defects in materials and workmanship. Esco's liability under this limited warranty shall be, at our option, to repair or replace any defective parts of the equipment, provided if proven to the satisfaction of Esco that these parts were defective at the time of being sold, and that all defective parts shall be returned, properly identified with a Return Authorization. This limited warranty covers parts only, and not transportation/insurance charges. This limited warranty does not cover: Freight or installation (inside delivery handling) damage. If your product was damaged in transit, you must file a claim directly with the freight carrier. Products with missing or defaced serial numbers. Products for which Esco has not received payment. Problems that result from: o External causes such as accident, abuse, misuse, problems with electrical power, improper operating environmental conditions. o Servicing not authorized by Esco. o Usage that is not in accordance with product instructions. o Failure to follow the product instructions. o Failure to perform preventive maintenance. o Problems caused by using accessories, parts, or components not supplied by Esco. o Damage by fire, floods, or acts of God. o Customer modifications to the product Consumables such as filters (HEPA, ULPA, carbon, pre-filters) and fluorescent / UV bulbs. Esco is not liable for any damage incurred on the objects used on or stored in Esco equipment. If the objects are highly valuable, user is advised to have in place independent external preventive measures such as connection to a centralized alarm system. Factory installed, customer specified equipment or accessories are warranted only to the extent guaranteed by the original manufacturer. The customer agrees that in relation to these products purchased through Esco, our limited warranty shall not apply and the original manufacturer's warranty shall be the sole warranty in respect of these products. The customer shall utilize that warranty for the support of such products and in any event not look to Esco for such warranty support. Esco encourages all users to register their equipment online at or complete the warranty registration form included with each product. ALL EXPRESS AND IMPLIED WARRANTIES FOR THE PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN TIME TO THE TERM OF THIS LIMITED WARRANTY. NO WARRANTIES, WHETHER EXPRESS OR IMPLIED, WILL APPLY AFTER THE LIMITED WARRANTY PERIOD HAS EXPIRED. ESCO DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES PROVIDED FOR IN THIS LIMITED WARRANTY OR FOR SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, ANY LIABILITY FOR THIRD- PARTY CLAIMS AGAINST YOU FOR DAMAGES, FOR PRODUCTS NOT BEING AVAILABLE FOR USE, OR FOR LOST WORK. ESCO'S LIABILITY WILL BE NO MORE THAN THE AMOUNT YOU PAID FOR THE PRODUCT THAT IS THE SUBJECT OF A CLAIM. THIS IS THE MAXIMUM AMOUNT FOR WHICH ESCO IS RESPONSIBLE. Formalin Vaporizer

6 iv These Terms and Conditions shall be governed by and construed in accordance with the laws of Singapore and shall be subject to the exclusive jurisdiction of the courts of Singapore. Technical Support, Warranty Service Contacts USA: Singapore: Global Helpdesk: Visit to talk to a Live Support Representative Distributors are encouraged to visit the Distributor Intranet for self-help materials. Product Appendix, Warranty Listings Biological Safety Cabinets, Laminar Flow Cabinets, HEPA-Filtered Cabinets (except Streamline brand) Laboratory Fume Hoods Ductless Fume Hoods Cleanroom Equipment Laboratory Ovens and Incubators CO 2 Incubators Containment/Pharma Products Ultralow Temperature Freezer The warranty periods for BSC may vary by country. Contact your local distributor for specific warranty details. 1 year limited. 3 years limited for Ascent Opti's, 5 years for Ascent Max's. 1 year limited. 1 year limited. 2 years limited. 2 years limited. 3 years limited. 60 months on Compressor. The warranty period starts two months from the date your equipment is shipped from Esco facility for international distributors. This allows shipping time so the warranty will go into effect at approximately the same time the equipment is delivered to the user. The warranty protection extends to any subsequent owner during the warranty period. Distributors who stock Esco equipment are allowed an additional four months for delivery and installation, providing the product is registered with Esco. User can register product online at or complete the warranty registration form included with each product. Policy updated on 12 th Apr 2011 (This limited warranty policy does not apply to products purchased before 12 th Apr 2011)

7 v 1. Products Covered Esco Formalin Vaporizer Electrical Rating V AC, 50Hz, 1Φ FV V AC, 50Hz, 1Φ FV Safety Warning Anyone working with, on or around this equipment should read this manual. Failure to read, understand and follow the instructions given in this documentation may result in damage to the unit, injury to operating personnel, and / or poor equipment performance. Any internal adjustment, modification or maintenance to this equipment must be undertaken by qualified service personnel. The use of any hazardous materials in this equipment must be monitored by an industrial hygienist, safety officer or some other suitably qualified individual. Before you process, you should thoroughly understand the installation procedures and take note of the environmental / electrical requirements. In this manual, important safety related points will be marked with the symbol. If the equipment is used in a manner not specified by this manual, the protection provided by this equipment may be impaired. 3. Limitation of Liability The disposal and / or emission of substances used in connection with this equipment may be governed by various local regulations. Familiarization and compliance with any such regulations are the sole responsibility of the users. Esco s liability is limited with respect to user compliance with such regulations. 4. European Union Directive on WEEE and RoHS The European Union has issued two directives: Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE) This product is required to comply with the European Union s Waste Electrical & Electronic Equipment (WEEE) Directive 2002/96/EC. It is marked with the following symbol: Esco sells products through distributors throughout Europe. Contact your local Esco distributor for recycling/disposal. Directive 2002/95/EC on Restriction on the use of Hazardous Substances (RoHS) With respect to the directive on RoHS, please note that this hood falls under category 8 (medical devices) and category 9 (monitoring and control instruments) and is therefore exempted from requirement to comply with the provisions of this directive. Formalin Vaporizer

8 vi

9 vii Declaration of Conformation In accordance to EN ISO/IEC :2010 We, Esco Micro Pte. Ltd. of 21 Changi South Street 1 Singapore, Tel: Fax: declare on our sole responsibility that the product: Category : Formalin Vaporizer Brand : - Model : FV-001 in accordance with the following directives: 2006/95/EEC : The Low Voltage Directive and its amending directives 92/31/EEC : The Electromagnetic Compatibility Directive and its amending directives has been designed to comply with the requirement of the following Harmonized Standard: Low Voltage : EN :2010 EMC : EN :2006 Class B More information may be obtained from Esco s authorized distributors located within the European Union. A list of these parties and their contact information is available on request from Esco. XQ Lin Group CEO, Esco This Declaration of Conformity is only applicable for 230V AC 50Hz units Formalin Vaporizer

10 viii

11 1-1.1 About Esco Formalin Vaporizer Esco formalin/ammonia vaporizer features a fully automatic decontamination and neutralization cycle which will switch off the heating cycle as soon as all of the formalin/ammonia solution has boiled, making the unit safer especially in overnight operations. It has a maximum capacity of 800 ml for each formalin and ammonia solution and may be used for biohazard safety cabinet decontamination. 1.2 Labels Model - The model of the unit. Serial - The serial number of the unit. Power - The power consumption and electrical requirement of the unit. Manufactured year - The year of manufacture. Formalin Vaporizer

12 2 1.3 Quick View Esco Sentinel Microprocessor Control System 2. On/Off switch 3. Formalin Tank Caps 4. Ammonia Tank Caps 5. Stainless Steel Grip Handle

13 3 2.1 Sentinel Control System MENU SET UP DOWN 1. Up ( ) and Down ( ) Arrow Button o Move the menu options upwards and downwards. o Increase and decrease corresponding value inside one of the menu options. 2. Set or Mute Button o Choose the menu or sub-menu currently displayed on the LCD screen. o Proceed to the next step or sequence inside one of the menu options. 3. Menu Button o To enter and exit from the menu options. o To go back to the previous level of the menu options. 2.2 Menu Options SET TIME HH:MM SET ADMIN PIN XXXX MENU PRE PROC TIME CONTACT TIME NEUTRAL TIME START PROCESS MM HH:MM HH:MM This part of the menu tree is only accessible before the decontamination process starts RESET DEFAULT RESUME STEP SKIP STEP CANCEL STEP This part of the menu tree is only accessible after the decontamination process starts Formalin Vaporizer

14 Before Decontamination Process Start Some of the menu in the Formalin Vaporizer can only be accessed before the decontamination process starts. This menu enables the operators to customize the vaporizer settings (preprocessing time, contact time and neutral time) according to their specific needs. During the decontamination process; this menu can no longer be accessed Set Time Users can set the time by increasing/decreasing the hour and minute values. The correct time will be maintained even after the unit is turned off. MENU SET TIME HH:MM TIME SET Set Administrator PIN This menu enables the operator to enable and disable admin PIN. The formalin vaporizer default admin PIN condition is disabled; however the operator can enable it by setting an admin PIN. To disable the admin PIN; set it to MENU SET ADMIN PIN XXXX CONFIRM PIN? Pre Processing Time Pre proc time or pre-processing time is the time between the formalin vaporizer start until the time the formalin vaporizing step starts. This time allows the operator to finish preparing the unit or room for decontamination i.e.: sealing a biological safety cabinet. The default preprocessing time is 10 minutes; however the operator can set the time between 01 and 59 minutes. MENU PRE PROC TIME MM PRE PROC TIME SET Contact Time Contact time is the formalin residence time or the time between the formalin vaporizing step ends until the ammonia vaporizing step starts. During the formalin vaporizing period (25%, 50%, 75% and 100% vaporized); it is a good idea to turn on the unit (biological safety cabinet, etc.) blower to circulate the formalin and enable the vapor to reach each crevice of the unit. The default contact time is 15 hours; however the operator can set it between 04:00 to 17:59. MENU CONTACT TIME HH:MM CONTACT TIME SET Neutral Time Neutral time is the ammonia residence time after the ammonia vaporizing step ends. The ammonia is needed to neutralize the formalin. During the ammonia vaporizing period (25%, 50%, 75% and 100% vaporized); it is a good idea to turn on the unit (biological safety cabinet, etc.) blower to circulate the formalin and enable the vapor to reach each crevice of the unit. The default neutral time is 8 hours; however the operator can set it between 01:00 to 17:59 MENU NEUTRAL TIME HH:MM NEUTRAL TIME SET Start Process This will start the decontamination process. The process will start with pre-processing step, and continue with formalin vaporizing step, contact time step, ammonia vaporizing step and finally neutral time MENU START PROCESS START PROCESS? EVACUATE

15 Reset Default This will start the decontamination process. The process will start with pre-processing step, and continue with formalin vaporizing step, contact time step, ammonia vaporizing step and finally neutral time step. MENU RESET DEFAULT READ MANUAL PRESS SET After Decontamination Process Start This menu can only be access during the decontamination process Resume Step This menu allows you to resume the decontamination process after a pause i.e. by accessing menu. If there s a power failure during the decontamination process, the formalin vaporizer will automatically resume the decontamination process once the power is recovered. In this case, the operator doesn t even need to access this menu. MENU RESUME STEP CONFIRM? Skip Step This allows you to skip a step in the decontamination process. MENU SKIP STEP SKIP STEP? Cancel Process This allow you to cancel the decontamination process altogether. MENU CANCEL STEP CANCEL PROCESS? Formalin Vaporizer

16 6

17 7 3.1 Formalin/Paraformaldehyde Decontamination Typically the decontamination is performed using formalin gas by either vaporizing 37% formalin solution or by de-polymerization of solid paraformaldehyde. Despite its widespread usage for decontamination, formalin presents the following health risks: External contact can cause irritation to skin, eyes, and mucous membranes. Inhalation in small concentrations can cause coughing, nausea, and diarrhea. Inhalation in large concentrations can cause convulsions, coma, and death. Long term exposure can cause cancer. Although the Permissible Exposure Level (PEL) for formalin is 0.75 ppm, many scientists believe that there is no safe level of carcinogen exposure to humans. Therefore, typically the room must be evacuated when the decontamination process is performed, which leads to lab down time. The use of formalin decontamination also has other disadvantages: The process is time-consuming. The certifier needs to pulse the BSC fan to circulate the formalin vapor. This can dislodge the tape holding the plastic sheet covering the exhaust filter. Due to excessive residue extensive cleaning must be done after decontamination and before use. The formalin decontamination process can require an extended period of time as outlined below: According to OSHA [Occupational Safety and Health Administration (USA)], formaldehyde Short Term Exposure Level (STEL) is 2 ppm for 15 minutes exposure, 4 times a day, minimum of 60 minutes in between exposures. Any additional local safety regulations should also be observed. Personnel should be given adequate training. The following links provide general guidelines on formaldehyde safety: Regulations (Standards - 29 CFR) Formaldehyde , Occupational Safety and Health Standards, OSHA (Occupational Safety and Health Administration), U.S. Department of Labor: OSHA Formaldehyde Fact sheet (PDF format) formaldehydefactsheet.pdf No. Process Time 1 Set-up & sealing the BSC to make it air tight 1 hour 2 Formalin vaporization ½ hour 3 Formalin contact time to obtain target log of 4-6 kill 8 10 hours 4 Ammonia vaporization to neutralize formalin ½ hour 5 Ammonia contact time to neutralize formalin 2 hours 6 Exhausting the ammonia residue 1 hour 7 Tear-down & cleaning the (substantial) residue 1 hour TOTAL without ammonia neutralization 10½ 12½ hours TOTAL with ammonia neutralization hours Ammonia is used to neutralize formaldehyde. OSHA prescribes the ammonia STEL is 35 ppm for 15 minutes exposure, 4 times a day, minimum of 60 minutes in between exposure. Due to the adverse health effect of formalin gas, its use has been banned in Germany, Austria, and Switzerland. Other European countries are expected to follow suit. Two primary candidates to replace formalin decontamination are chlorine dioxide gas and hydrogen peroxide vapor. Formalin Vaporizer

18 8 3.2 Common Equipment Used in Decontamination Common Equipment Device to measure formaldehyde concentration FormaldemeterR 400 has been found to be suitable and can be obtained from: PPM Technology (UK) - Device to measure ammonia concentration DragerR-Tubes and AccuroR pumps have been found to be suitable: Dragerwerk AG (Germany) - Tubes with a measuring range of ppm are recommended Formalin vaporizer o FV-001 Formalin Vaporizer V, 50/60 Hz o FV-002 Formalin Vaporizer V, 50/60 Hz Esco Micro Pte. Ltd. - Spore strips (optional) to verify decontamination efficacy Appropriate PPE A solid front-back closing, full body, long-sleeved disposable lab gown Disposable shoe covers Disposable surgical/pvc gloves for hand protection Note: Gloves should be pulled over the knitted wrists of the gown rather than being worn inside. Double gloving should be considered. Gloves must be worn while handling formalin and ammonia solutions. Compared to latex gloves, Nitrile gloves exhibit higher resistance to formaldehyde and are less likely to cause allergic skin reactions. Hence Nitrile gloves are preferred over latex gloves. Full-faced mask with a disposable dust and mist respirator. The face shield should be wiped clean with a suitable tissue and water each time after using it Common Apparatus Beaker Measuring cylinder Tape Decontamination bag Measuring tape Biohazard waste bag 3.3 Preparation Steps 1. It is recommended that a safety briefing be conducted for all personnel in the laboratory where the unit has been placed before carrying out the procedure. 2. Access to the laboratory should be restricted during the procedure, especially when you re using formalin vapor/ paraformaldehyde gas and chlorine dioxide gas. A warning sign should be pasted on the door of the lab to warn all personnel. No personnel should enter the lab until the procedure is complete and the decontamination agent s concentration has been verified to be within safe limits. 3. Prior to starting the procedure, contingency plans should be drawn for possible incidences of breach in the unit seal, leading to leakage of decontamination agent into the room. You should properly study the ventilation design of the room and should keep appropriate equipment on standby so the agent can be vented in the event of a leakage. One way of doing this would be to connect a flexible hose to a small exhaust fan which can vent the contaminated air into an adjacent fume hood. Special care should also be taken in case the air in the laboratory is re-circulated to other parts of the building. In such a case, a leakage could even necessitate evacuation of other parts of the building. 4. All interior work zones and surfaces of the unit should be decontaminated with a suitable disinfectant before performing gaseous decontamination.

19 9 3.4 Recommended Decontamination Sealing Method For Unit without Ducting Put the decontamination bag to enclose the entire BSC and support stand Use the 50 mm wide aluminum tape to seal the gap between the decontamination bag and the floor. To compensate for areas where the decontamination bag must turn, use multi section tape. Ensure that the two layers of tape overlap at the end points to prevent leakage. Overlap the tape at the joints These 2 cables (for BSC and for vaporizer) should be combined so that only 1 cable should come out from the decontamination bag, to minimize chance of formalin leakage To seal the cable, first make an Ω-shape aluminum tape around the cable, and make a 5 cm flat portion going to both directions. Then, paste the aluminum tape to the floor. Put the bottom part of the decontamination bag on top of the aluminum tape, and then seal it with another layer of aluminum tape. Use multiple layer of aluminum tape (at least 2 layers) on both directions to ensure leak tightness. Formalin Vaporizer

20 10 The BSC is ready for formalin decontamination For Unit with Ducting For ducted Unit, you will need to cut a portion of the bag to accommodate the ducting system. The decontamination method itself is basically the same as the non-ducted Unit shown above with some additional steps, namely: Close the air tight damper Wrap the bag around the ducting system and seal it using aluminum tape. Use multiple layer of aluminum tape to make sure that it is sealed correctly. Create a rounded shape using aluminum tape so the adhesive part is on the outside. Use it to put the bag together. Seal the connection with multiple layers of aluminum tape to ensure its leaktightness.

21 Decontamination Process There are two alternative combinations of decontaminants and their corresponding neutralizers that are commonly used: 1. 37% formalin solution (HCHO) with 25% ammonia solution (NH4OH) being the neutralizer 2. Paraformaldehyde with ammonium bicarbonate (NH4CO3) being the neutralizer 3. The decontamination processes carried out using these two combinations are slightly different. Both these processes are discussed in details. It is very important to ensure compliance with local laws and regulations with respect to the above mentioned techniques. For instance, if local environmental regulation prohibits the release for formalin vapor into outside environment, the formalin vapor needs to be neutralized by ammonia first, before their byproduct can be exhausted outside. Connecting a temporary duct to the Unit, with the gas being released into a fume cupboard. Connecting a temporary duct to the external atmosphere using a temporary form connection. Using the existing duct connection of the Unit to exhaust the gas (This is applicable only if the Unit is itself ducted). It is very important to ensure compliance with local laws and regulations with respect to the above mentioned techniques. For instance, if local environmental regulation prohibits the release for formalin vapor into outside environment, the formalin vapor needs to be neutralized by ammonia first, before their byproduct can be exhausted outside Formalin Ammonia Combination Calculate the amount of 37% formalin, 25% ammonia, and water required, which is 85 ml each, for every 1 cubic meter volume to be decontaminated. Water is poured into the formalin tank to increase the decontamination area humidity to be above 60%. If the room humidity already exceeds 60%, and the formalin tank usage needs to be optimized to decontaminate a large space, such as a small room, then there is no need to add water. Please note that the water shall not be poured into the ammonia tank because it will not assist in the decontamination process. After approximately 25, 50, 75, and 100% of the formalin being evaporated, turn on the Unit blower for 10 to 15 seconds to circulate the formalin throughout the Unit. In cases where Unit blower is inoperative, circulation of air inside the Unit should be promoted with additional blower or fans, or the time of decontamination should be extended beyond the times suggested below. Allow the formalin vapor a minimum 6 hours (10 to 12 hours is preferable) contact time inside the Unit. Once the formalin decontamination time is reached, start the apparatus containing 25% ammonia to neutralize the formaldehyde. It is recommended to circulate the ammonia by turning on the Unit blower at the same interval as the formalin vaporization. Without any circulation, the neutralization time should be extended to a minimum of 6 hours. Let the ammonia vapor to have a contact time of at least 1 hour (2 hours is preferable) after the solution has been completely evaporated, before opening the seals. Please be aware that the formalin and/or ammonia concentration inside the decontamination bag may be above the STEL and full face mask with formalin filter is required when opening the decontamination bag Paraformaldehyde Ammonium Bicarbonate Combination Additional apparatus needed: Heating device (e.g. frying pan) Aluminum foil Formalin Vaporizer

22 12 1. Based on the volume, calculate the amount of paraformaldehyde and ammonium bicarbonate needed as follows: o Paraformaldehyde amount (gram): Total volume (m3) x 11gram/m3 o Ammonium bicarbonate amount (gram): Steps to determine the amount of Ammonium Bicarbonate required: a. Determine the stoichiometric amount of ammonium bicarbonate needed to produce the requisite amount of ammonia gas that would neutralize the resulting formaldehyde gas. b. To ensure completion of the reaction, make sure that the weight of ammonium bicarbonate is 10% greater than the weight of the paraformaldehyde used. 2. Typically, formaldehyde is non-penetrative. So the Unit does not have to be pressure tight. Completely seal the Unit and ensure air-tightness inside the enclosure by using tapes at all appropriate places. Pay special attention to the power supply cables. 3. Wear appropriate protective clothing. 4. Spread the paraformaldehyde evenly over the surface of the heating device. Set the thermostat to 232 C to 246 C (450 F to 475 F). 5. Another heating device is placed on the work tray for the ammonium bicarbonate. At this stage, the ammonium bicarbonate should be restricted from mixing with the air in the Unit. Following are two ways of restricting Ammonium Bicarbonate: Method 1: 1. Spread the ammonium bicarbonate evenly over the surface of the heating device and then cover the device with aluminum foil in such a way that ammonium bicarbonate cannot react with formaldehyde while decontamination is in progress. 2. The aluminum foil can be placed in such a way that it allows ammonia gas to escape when the device is heated. Alternatively, some provision can be made for removing the aluminum foil remotely at the beginning of the neutralization phase. 3. Make sure that the deployment of such a removal mechanism doesn t lead to unsafe levels of formaldehyde escaping out of the decontamination bag enclosing the Unit. Method 2: Seal the Unit using a special plastic sheet that has a pair of gloves built into it. The ammonium bicarbonate is placed in a sealed container inside the Unit. Using the built-in gloves, the person performing the decontamination would be able to reach the work zone of the Unit without having to break the seal. At the beginning of the neutralization phase, ammonium bicarbonate is removed from the sealed container and spread evenly over the surface of the heating device. The heating device is then switched on so that ammonia is generated from ammonium bicarbonate. 1. After approximately 25, 50, 75, and 100% of the formalin being evaporated, turn on the Unit blower for 10 to 15 seconds to circulate the formalin throughout the unit. 2. In cases where Unit blower is inoperative, circulation of air inside the Unit should be promoted with additional blower or fans, or the time of decontamination should be extended beyond the times suggested below. 3. Allow the formalin vapor a minimum 6 hours (10 to 12 hours is preferable) contact time inside the unit. 4. Once the formalin decontamination time is reached, start the apparatus containing 25% ammonium bicarbonate to neutralize the paraformaldehyde. It is recommended to circulate the ammonia by turning on the Unit blower at the same interval as the formalin vaporization. Without any circulation, the neutralization time should be extended to a minimum of 6 hours. 5. Let the ammonia vapor to have a contact time of at least 1 hour (2 hours is preferable) after the solution has been completely evaporated, before opening the seals. Please be aware that the formaldehyde and/or ammonia concentration inside the decontamination bag may be above the STEL and full face mask with formalin filter is required when opening the decontamination bag.

23 Completion Steps Check the ammonia concentration in room air Check the formaldehyde concentration in room air at the end of decontamination cycle, prior resuming work on the BSC Check the formaldehyde and ammonia concentration in the BSC During the procedure, until the area is determined to be safe, a full face gas mask equipped with a formaldehyde canister should be worn. The filter for the mask must be selected for the appropriate level of formaldehyde exposure. It must also be replaced regularly following the manufacturer s instruction Remove the disposible gown and gloves carefully and wash hands using germicidal soap thoroughly Remove the decontamination bag that enclosed the BSC Remove all apparatus from inside the BSC 3.7 Decontamination Validation Procedure (optional) Place some Bacillus subtilis var.niger spore strips inside the Unit prior to decontamination. o Work surface/table tray o Drain pan o Downstream HEPA filter Place similar strips outside the decontamination room for positive control (optional). Remove all the spore strips and place in trypticase-soy broth and incubate for 2 days at 37 C. If there is no growth of bacteria inside the broth (the broth remains clear), the decontamination procedure has been successfully verified. Formalin Vaporizer

24 14

25 APPENDIX

26

27 Equipment : Serial Number : Person in Charge : 1. This log record should be used by the operator to record any new agent that has been introduced to the equipment during its operation, problems encountered, etc. 2. Any decontamination procedure performed by either the user or the technician should be recorded down as well. 3. Please also record any major maintenance procedure performed by the service technician, for example: parts replacement, recertification, etc. Date Event User Signature Supervisor Signature In case of emergencies, please call: Name : Cell Phone Number :

28

User Manual. Powder Weighing Balance Enclosure

User Manual. Powder Weighing Balance Enclosure Thank you for purchasing this Esco Powder Weighing Balance Enclosure. Please read this manual thoroughly to familiarize yourself with the many unique features and exciting innovations we have built into

More information

User. Manual. Ascent OPTI Ductless Fume Hood

User. Manual. Ascent OPTI Ductless Fume Hood Thank you for purchasing this Esco Biological Safety Cabinet. Please read this manual thoroughly to familiarize yourself with the many unique features and exciting innovations we have built into your new

More information

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc.

Calibration Gas Instrument INSTRUCTION MANUAL. Release I. Advanced Calibration Designs, Inc. Advanced Calibration Designs, Inc. Calibration Gas Instrument INSTRUCTION MANUAL Release I www.goacd.com Instruction Manual Gas Generator Release I TABLE OF CONTENTS I. General Description Page 2 II. Start-Up

More information

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax:

Operating Instruction Manual for Liquid Nitrogen Containers. CRY/CRYC Series. Hagavish st. Israel Tel: , Fax: Operating Instruction Manual for Liquid Nitrogen Containers CRY/CRYC Series Hagavish st. Israel 58817 Tel: 972 3 5595252, Fax: 972 3 5594529 mrc@mrclab.com MRC.12.14 TO USER Thank You! You have just purchased

More information

Standard Operating Procedure (SOP)

Standard Operating Procedure (SOP) INTRODUCTION This SOP applies to. FORMALDEHYDE exposure in Anatomy Lab will be monitored at the beginning of each semester dissections are performed. Environmental Health and Safety will perform monitoring

More information

Approval Block. Prepared by: Signature Date. Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Approval Block. Prepared by: Signature Date. Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date ATS-SOI-3490 Page: 1 of 6 Approval Block Prepared by: Signature Date Evan Parnell 08 NOV 2013 Reviewed by: Signature Date Brian Flynn 08 NOV 2013 Approved by: Signature Date Kristal Jewell 08 NOV 2013

More information

Laboratory Self Inspection Checklist LAB01

Laboratory Self Inspection Checklist LAB01 Laboratory Self Inspection Checklist LAB01 General Chemical/Biological Laboratories Location Assessor Date This core checklist is provided by the Health and Safety Department as a template, which provides

More information

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area.

The primary purpose of laboratory fume hoods is to keep toxic or irritating vapors out of the general laboratory working area. Introduction Welcome to the Biosafety Cabinets and Fume Hoods Training Course (OHS_BIO304). This training is required for anyone that will be conducting work and/or research that requires the use of a

More information

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY Page 1 of 9 ISSUED: 5/00 REVISED: 08/06 Introduction Purpose: In accordance with applicable regulations and Temple University, this policy was developed to minimize exposure to Ethylene Oxide. Applicability

More information

Modular skylight warranty

Modular skylight warranty Modular skylight warranty Specific limited product warranty 10 year limited warranty (a) (b) (c) VELUX insulating glass For a period of (10) ten years from the date of purchase, VELUX warrants to the end-user

More information

Cadence Sensor W.I.N.D. User Manual

Cadence Sensor W.I.N.D. User Manual Cadence Sensor W.I.N.D. User Manual Polar Cadence Sensor W.I.N.D. is designed to measure cadence, i.e. crank revolutions per minute when cycling. No other use is intended or implied. Please follow the

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document No. 1800-75 Respiration Test Chamber Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA

More information

4-in-1 Professional Inflator Kit

4-in-1 Professional Inflator Kit 4-in-1 Professional Inflator Kit Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety

More information

A. Evaluation of the written program

A. Evaluation of the written program A. Evaluation of the written program Begin your audit with an evaluation of the written respiratory protection program. In addition to the operating procedures describing respirator selection and use in

More information

92831 TEL: (714) FAX:

92831 TEL: (714) FAX: Document N0. 1800-03 Copyright 2010 Terra Universal Inc. All rights reserved. Revised Sept. 2010 Terra Universal, Inc. TerraUniversal.com 800 S. Raymond Ave. Fullerton, CA 92831 TEL: (714) 578-6000 FAX:

More information

Portable Gas Monitor GX User Maintenance Manual (H4-0050)

Portable Gas Monitor GX User Maintenance Manual (H4-0050) H4E-0050 Portable Gas Monitor GX-8000 User Maintenance Manual (H4-0050) Need of Maintenance and Servicing This gas monitor must be maintained in a normal state at all times to prevent accidents due to

More information

Operating Manual VSA100A. tina29e1 ( )

Operating Manual VSA100A. tina29e1 ( ) Operating Manual Incl. EU Declaration of Conformity Vacuum Switch VSA100A tina29e1 (2017-05) 1 Product Identification In all communications with INFICON, please specify the information on the product nameplate.

More information

RAM 4021 Operation Manual

RAM 4021 Operation Manual RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For your safety...3 Description...3 Set-up mode...4 Annunciator lights/alarms...4 Operation...5 Calibration...6

More information

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100

PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 MPS-1100 User Manual Mega Pool Saver Ltd PLEASE READ CAREFULLY BEFORE INSTALLING OR USING MEGA POOL SAVER MPS 1100 For further up to date instructions on how to install Mega Pool Saver MPS 1100, please

More information

453 Series Steam Heated Vaporizing Regulator

453 Series Steam Heated Vaporizing Regulator ADI 0453A Certified ISO 9001:2000 453 Series Steam Heated Vaporizing Regulator INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls Corporation

More information

GUIDELINES FOR HANDLING EXTERNALLY CONTAMINATED MEDICAL CYLINDERS IN A PANDEMIC SITUATION

GUIDELINES FOR HANDLING EXTERNALLY CONTAMINATED MEDICAL CYLINDERS IN A PANDEMIC SITUATION GUIDELINES FOR HANDLING EXTERNALLY CONTAMINATED MEDICAL CYLINDERS IN A PANDEMIC SITUATION AIGA 077/11 Asia Industrial Gases Association 3 HarbourFront Place #09-04 HarbourFront Tower 2 Singapore 099254

More information

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE

CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE CONTROL OF SUBSTANCES HAZARDOUS TO HEALTH PROCEDURE 1. INTRODUCTION The University uses substances hazardous to health in many of its operations, and accepts that it has a duty of care to reduce exposure

More information

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE

SUBSTATION MAINTENANCE ELECTRICAL OPERATING PROCEDURE Page 1 of 6 A. PURPOSE AND SCOPE This procedure establishes safe working practices for handling sulfur hexafluoride (SF 6 ) gas and release minimization practices. This document also specifies methods

More information

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports

URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT for use with MRX units containing sensor ports URC Voltage Sensor SEN-VOLT 2013 Universal Remote Control, Inc. The information in this Owner s Manual is copyright protected.

More information

User. Manual. Ductless Fume Hood

User. Manual. Ductless Fume Hood Thank you for purchasing this Esco Ductless Fume Hoods. Please read this manual thoroughly to familiarize yourself with the many unique features and exciting innovations we have built into your new equipment.

More information

Toolkit for safe Use of Microbiological Safety Cabinets(MSC s)

Toolkit for safe Use of Microbiological Safety Cabinets(MSC s) Toolkit for safe Use of Microbiological Safety Cabinets(MSC s) What Do I Need To Do? How Do I Manage the Use of MSC s Recommendations 1 What Do I Need To Do Head of Department? Information, induction,

More information

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY Purpose In accordance with applicable regulations and Temple University, this policy was developed to minimize exposure to glutaraldehyde. Applicability This policy is applicable to all Temple University

More information

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation

ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS Dionex Corporation ASE SOLVENT CONTROLLER INSTALLATION INSTRUCTIONS 2000 Dionex Corporation Document No. 031277 Revision 03 April 2000 2000 Dionex Corporation All rights reserved worldwide. Printed in the United States of

More information

Installation Procedure Esco Miri Multi-Room Incubator

Installation Procedure Esco Miri Multi-Room Incubator Esco Miri Multi-Room Incubator Version 1.1 ESCO MEDICAL Esco Micro Pte Ltd 21 Changi South Street 1 Singapore 486777 Tel. : +65 6542 0833 Fax : +65 6542 5732 / 6546 2913 Mail : csis-medical@escoglobal.com

More information

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC

INSTRUCTION MANUAL. Includes: OPERATION SETUP USE & CARE SERVICE. SPORTS ATTACK LLC Electronic Baseball Pitching Machine baseball INSTRUCTION MANUAL PART NO. B-EHABA-100 REV022111 INSTRUCTION MANUAL Includes: OPERATION SETUP USE & CARE SERVICE SPORTS ATTACK LLC 800-717-4251 www.sportsattack.com

More information

Accu-Tab PowerBase 3012AT by Axiall Corporation

Accu-Tab PowerBase 3012AT by Axiall Corporation Accu-Tab PowerBase 3012AT by Axiall Corporation Installation and Operating Instructions DANGER: DO NOT MIX CHEMICALS! The PowerBase 3012AT chlorinator system is designed for use with Axiall Corp. approved

More information

The Univentor 1250 Anaesthesia Unit

The Univentor 1250 Anaesthesia Unit THE UNIVENTOR 1200/1250 ANAESTHESIA UNIT The Univentor 1250 Anaesthesia Unit TABLE OF CONTENTS EDITION 1 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2

More information

Operator s Manual. The Bullet Blender Gold BB24-AU, BB5E-AU

Operator s Manual. The Bullet Blender Gold BB24-AU, BB5E-AU Operator s Manual The Bullet Blender Gold BB24-AU, BB5E-AU Congratulations! Congratulations on your purchase of a Bullet Blender Gold by Next Advance, Inc., for lysing, disrupting, and homogenizing your

More information

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter. Visit us online at.

Owners Manual Models: 075-AQF-CX. Aquatrol Backwashing Catalytic Carbon Filter.  Visit us online at. Visit us online at www.uswatersystems.com Aquatrol Backwashing Catalytic Carbon Filter Owners Manual Models: 075-AQF-CX REVISION # 1.0 REVISION DATE October 11, 2017 US Water Systems, Inc. 1209 Country

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

RG3100 and RG3100Ice Regulator System

RG3100 and RG3100Ice Regulator System RG3100 and RG3100Ice Regulator System User Guide www.diverite.com Date of purchase: www.diverite.com RG1208-5 & RG1208-5Ice www.diverite.com First Stage Regulator Product Description The RG1208-5 and RG1208-5Ice

More information

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual

SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual SDS -Series 4C-D201/-D202 Supplemental Drying System User s Manual 8 Executive Drive P.O. Box 2105 Toms River, NJ 08754 (732) 244-0010 (800) 337-3762 fax (732) 244-8140 www.permapure.com info@permapure.com

More information

Laboratory Safety Training. Environmental Health and Safety

Laboratory Safety Training. Environmental Health and Safety Laboratory Safety Training Environmental Health and Safety Why You Need Lab Safety Training Hazardous materials and/or equipment. You need to understand the risks and how to mitigate them. OSU requires

More information

Laboratory Standard Operating Procedure: Acutely Toxic Substances

Laboratory Standard Operating Procedure: Acutely Toxic Substances I. CONTACT INFORMATION Procedure Title Procedure Author Date of Creation/Revision: April 12, 2013 Name of Responsible Person Location of Procedure (The PI, Lab Supervisor, or Autonomous Researcher) (Building

More information

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures

INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures INSTALLATION MANUAL Matheson Tri-Gas Cabinet Enclosures MINT-0289-XX TABLE OF CONTENTS Limited Warranty... 3 User Responsibility... 3-4 General Service... 4 Safety Precautions.... 5 Physical Dimensions..

More information

AND OPERATION INSTRUCTIONS

AND OPERATION INSTRUCTIONS ADI 2111-D Certified ISO 9001 MEDICAL FLOWMETER (Back Pressure Compensated Thorpe Tube) INSTALLATION AND OPERATION INSTRUCTIONS Before Installing or Operating, Read and Comply with These Instructions Controls

More information

Laboratory Standard Operating Procedure: Sensitizers

Laboratory Standard Operating Procedure: Sensitizers I. CONTACT INFORMATION Procedure Title Procedure Author Date of Creation/Revision: April 12, 2013 Name of Responsible Person Location of Procedure (The PI, Lab Supervisor, or Autonomous Researcher) (Building

More information

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor INSTALLATION and INSTRUCTION MANUAL for QUALITY AIR BREATHING SYSTEMS Model 50-P-Mini Portable Systems Outfitted with ABM-725 Monitor M A R T E C H S E R V I C E S C O M P A N Y P.O. Box 7079 OFFICE: (507)

More information

Accu-Tab Systems 2000 P Series by Axiall Corporation

Accu-Tab Systems 2000 P Series by Axiall Corporation Accu-Tab Systems 2000 P Series by Axiall Corporation Installation and Operating Instructions Models 2075 P 2150 P For NSF/ANSI-Standard 61 NSF STANDARD 61 applications use NSF/ANSI Standard 60 listed Axiall

More information

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING

E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING. Leader s Guide ERI Safety Videos EMPLOYEE TRAINING E3628 THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING Leader s Guide 2007 ERI Safety Videos THE RESPIRATORY PROTECTION PROGRAM: EMPLOYEE TRAINING This easy-to-use Leader s Guide is provided to assist

More information

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451.

Cabinet. 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory Protection Standard Part 451. Calvin College Respiratory Protection Program Prepared by: Date: Heather Chapman 10/7/10 Approved by: Cabinet Revision 2 Date: 1.0 POLICY It is the policy of Calvin College to comply with the MIOSHA Respiratory

More information

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM 4021-PR. Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021-PR Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021-PR For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4

More information

PRAHER PLC-MP AQUASTAR MANAUL 2009

PRAHER PLC-MP AQUASTAR MANAUL 2009 PRAHER PLC-MP AQUASTAR MANAUL 2009 1. Copyrights This Operating Manual contains copyright-protected information. All rights reserved to Praher Kunststofftechnik GmbH. This Operating Manual is designed

More information

TOWN OF LINCOLN ARENA FACILITIES OPERATIONAL SAFETY POLICY

TOWN OF LINCOLN ARENA FACILITIES OPERATIONAL SAFETY POLICY Policy Number: PW 2008-04 Page 1 of 5 Authored by Department: Department PURPOSE The Purpose of this policy is to establish formal safety procedures for municipal workers who perform routine maintenance

More information

Standard Operating Procedure

Standard Operating Procedure Standard Operating Procedure Cleaning Ni Columns Department: Date SOP was written: Date SOP was approved by PI/lab supervisor: 12/29/2012 Reviewed by: Principal Investigator: Internal Lab Safety Coordinator/Lab

More information

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity

WATER HEATER THERMAL EXPANSION TANKS Owner s Manual. Safety Instructions Installation Maintenance Warranty. Models: 2-5 Gallon Capacity WATER HEATER THERMAL EXPANSION TANKS Owner s Manual Safety Instructions Installation Maintenance Warranty Models: 2-5 Gallon Capacity Thank You for purchasing this Thermal Expansion Tank. Properly installed

More information

Owner s. product. Failure injury

Owner s. product. Failure injury 100-Ft. Hose Reel Cart Owner s Manual WARNING: Read and understand all instructions, warnings, and cautions before using this product. Failure to follow the instructions, warnings, and cautions may result

More information

Accu-Tab Systems 1000 Series by Axiall Corporation

Accu-Tab Systems 1000 Series by Axiall Corporation Accu-Tab Systems 1000 Series by Axiall Corporation Installation and Operating Instructions Model 1050 DANGER: DO NOT MIX CHEMICALS! The Accu-Tab chlorinator is designed for use with Axiall approved tablets

More information

Hazardous Materials Spill Response

Hazardous Materials Spill Response Hazardous Materials Spill Response The University of Iowa Rev. 01/2019 Department: Lab/Room Number: PI/Lab Coordinator: After-hours Contact Number: University Public Safety - 911 Fire, Police, Ambulance

More information

AA100 Acoustic Actuator

AA100 Acoustic Actuator AA100 Acoustic Actuator Operating Manual REV. A, September 2001 COPYRIGHT 2001. ALL RIGHTS RESERVED Return Procedure It is necessary to obtain from ORE Offshore a Returned Material Evaluation (RMA) number

More information

Angled Sign Light with Shade

Angled Sign Light with Shade Angled Sign Light with Shade Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

Hazardous Materials Spill Response

Hazardous Materials Spill Response Hazardous Materials Spill Response The University of Iowa Rev. 02/10 Department Lab/Room Number PI/Lab Coordinator After Hours Contact Number University Public Safety (Phone 911) Fire, Police, Ambulance

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR

SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR S S F U SSFU SUPER SPRAYFAST UNIVERSAL ADHESIVE APPLICATOR MACHINERY DIVISION OWNER S MANUAL UNIT INSTRUCTIONS Please follow all SSFU Safety Instructions. Contact your Duro Dyne Tech Service if you have

More information

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable

Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable Half Facepiece Respirator Assembly 5000 Series, Dual Cartridge, Disposable User Instructions for 3M Organic Vapor Respirator Assembly 5101/5201/5301; 3M Organic Vapor/Acid Gas Respirator Assembly 5103/5203/5303;

More information

Safety Services. Introduction

Safety Services. Introduction Safety Services Guidance on the Selection, Installation, Maintenance and Operation of Microbiological Safety Cabinets for use in containment level 2 (CL2) laboratories Introduction 1. Microbiological safety

More information

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model Installation and Operating Instructions Compact Triple Cabinet Outlet Station Model 6258-1 Installation and Operating Instructions The Porter Compact Triple Outlet Station (6258-1) provides a quick, safe, and reliable method of connection to

More information

Use of Biosafety II cabinets

Use of Biosafety II cabinets RISK ASSESSMENT FORM Use this form to assist you to complete risk assessments for hazardous activities and processes. Any serious or ongoing hazards should be reported via RiskWare to ensure that appropriate

More information

Norrsken Family Booklet

Norrsken Family Booklet Section 1: Introduction Low Energy Designs produce efficient and effective LED based lighting products for commercial, retail and industry purposes. Each product may contain specific details on its operation

More information

RG2200 BC Integrated Octopus

RG2200 BC Integrated Octopus 175 NW Washington Street Lake City, Florida 32055, USA Web: www.diverite.com Phone: 386.752.1087 Fax: 386.755.0613 RG2200 BC Integrated Octopus Product description The Rite Source is both a BC inflation/deflation

More information

Respiratory Protection Self Inspection Checklist

Respiratory Protection Self Inspection Checklist Optional Information Name of School: Date of Inspection: Vocational Program/Course/Room: Signature of Inspector: Respiratory Protection Self Inspection Checklist Guidelines: This checklist covers some

More information

FLANGED TWO-PIECE BALL VALVES

FLANGED TWO-PIECE BALL VALVES INTRODUCTION This instruction manual includes installation, operation, and maintenance information for FNW flanged split-body ball valves. This manual addresses lever operated ball valves only. Please

More information

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions

Compact Triple Cabinet Outlet Station Model B Installation and Operating Instructions PORTER Parker Hannifin Corporation Porter Instrument Division 245 Township Line Rd. P.O. Box 907 Hatfield, PA 19440-0907 USA (215) 723-4000 / fax (215) 723-5106 Compact Triple Cabinet Outlet Station Model

More information

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013

Instruction Sheet. SUPERSEDES: New EFFECTIVE: August 1, 2013 Instruction Sheet 102-492 5123-WH-N Lead Free (.25% Pb) Mixing Valve SUPERSEDES: New EFFECTIVE: August 1, 2013 Plant I.D. 001-4206 WARNING: Water temperatures above 120 F can cause serious injury. Mixing

More information

Confined Space. Program Responsibilities

Confined Space. Program Responsibilities Confined Space CONFINED SPACE ENTRY AND RESCUE The OSHA standard on Permit-Required Confined Spaces (29 CFR 1910.146) requires employers to implement practices and procedures to protect employees from

More information

Laboratory Standard Operating Procedure: Carcinogens

Laboratory Standard Operating Procedure: Carcinogens I. THIS STANDARD OPERATING PROCEDURE (SOP) IS FOR A: Specific laboratory procedure or experiment Examples: synthesis of chemiluminescent esters, folate functionalization of polymeric micelles, etc. Generic

More information

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar

Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar EN - english Instructions for installation and operation Measurement accessories METPOINT OCV for the measurement in systems up to 40 bar Dear customer, Thank you for deciding in favour of the METPOINT

More information

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems

Oxygen Concentrator. Installation and Operation Manual. ClearWater Tech, LLC. Integrated Ozone Systems Oxygen Concentrator Installation and Operation Manual ClearWater Tech, LLC. Integrated Ozone Systems 850-E Capitolio Way, San Luis Obispo, Ca 93401 805-549-9724 Fax: 805-549-0306 E-mail: service@cwtozone.com

More information

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0

TL-12 FLUSH TANK. Manual Ref. # MN-??? Polyurethane Machinery Corp. REVISION 1.0 TL-12 FLUSH TANK Manual Ref. # MN-??? REVISION 1.0 Polyurethane Machinery Corp. Corporate: 1 Komo Dr, Lakewood, NJ 08701 Manufacturing: 2 Komo Dr, Lakewood, NJ 08701 Phone: 732-415-4400 Fax: 732-364-4025

More information

RAM 4021-DPX Operation Manual

RAM 4021-DPX Operation Manual RAM 4021-DPX Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS ABL 4021-DPX / RAM 4021-DPX For Your Safety... 3 Description... 3 Setup Mode... 4 Lights/Alarms... 4 Operation...

More information

MATERIAL SAFETY DATA SHEET. : Palm Kernel Expeller

MATERIAL SAFETY DATA SHEET. : Palm Kernel Expeller MATERIAL SAFETY DATA SHEET Palm Kernel Expeller Section 1 - Chemical Product and Company Identification MSDS Name : Palm Kernel Expeller Company Identification : Tradeasia International Pte Limited Address

More information

Gas and Vacuum Tubing Connection Kit for Manual Operation, No

Gas and Vacuum Tubing Connection Kit for Manual Operation, No LABCONCO CORPORATION 8811 Prospect Ave, Kansas City, MO 64132 (816) 333-8811, Fax (816) 363-0130, (800) 821-5525 Gas and Vacuum Tubing Connection Kit for Manual Operation, No. 5245100 Operation The Gas

More information

PC1131 Electric Air Compressor

PC1131 Electric Air Compressor Senco Products Inc. 8485 Broadwell Road Cincinnati, Ohio 45244 PC1131 Electric Air Compressor Operating Instructions C US 2006, 2007 by Senco Products, Inc. Warnings for the safe use of this tool are included

More information

Laboratory Standard Operating Procedure: Reproductive Toxins

Laboratory Standard Operating Procedure: Reproductive Toxins I. CONTACT INFORMATION Procedure Title Procedure Author Date of Creation/Revision: April 12, 2013 Name of Responsible Person Location of Procedure Approval Signature (The PI, Lab Supervisor, or Autonomous

More information

Pressure Relief Valve Instruction Manual

Pressure Relief Valve Instruction Manual CVR3-M0_062017 Pressure Relief Valve Instruction Manual MODEL: CVR3 SFA Companies 10939 N. Pomona Ave. Kansas City, MO 64153 Tel: 888-332-6419 * Fax: 816-448-2142 E-mail: sales@bvahydraulics.com Website:

More information

INSTRUCTIONS PARTS LIST

INSTRUCTIONS PARTS LIST 3066V-E INSTRUCTIONS PARTS LIST INSTRUCTIONS! This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. AQ Poppet Color Valve (3066-41-00A) 304 Stainless Steel Body Autoquip,

More information

The routine maintenance and inspection of local exhaust ventilation (LEV)

The routine maintenance and inspection of local exhaust ventilation (LEV) The routine maintenance and inspection of local exhaust ventilation (LEV) This document details the standards for inspection and maintenance that should be achieved for all local exhaust ventilation owned

More information

G7S Hand Pump Owner s Manual

G7S Hand Pump Owner s Manual G7S Hand Pump Owner s Manual Copyright Air Venturi 2018 Version 4-18 Specifications 24.80 inches long closed 43.31 inches long extended 4500 psi/310 bar max pressure Features Integral manometer (pressure

More information

EC214 EC215 - EC215R Bench Conductivity Meters

EC214 EC215 - EC215R Bench Conductivity Meters Instruction Manual EC214 EC215 - EC215R Bench Conductivity Meters http://www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you for choosing a Hanna Instruments

More information

PERSONAL AIR BREATHING UNIT

PERSONAL AIR BREATHING UNIT PERSONAL AIR BREATHING UNIT Operation & Maintenance Manual MARTECH SERVICES C O M P A N Y 1-800-831-1525 Table of Contents INTRODUCTION: Page 2 COMPONENTS DRAWING: Page 3 START UP: Page 4 OPERATION: Page

More information

M5400 Operators Manual

M5400 Operators Manual M5400 Operators Manual For Veterinary Use Only Supera, LLC Copyright 2012 Examination and Preparation for Use Thank you for ordering an Supera Anesthesia Innovations anesthesia machine! We are delighted

More information

SPECIFICATIONS APCEPH1

SPECIFICATIONS APCEPH1 APCEPH1 ph CONTROLLER SPECIFICATIONS APCEPH1 Input voltage 120 Volts AC Maximum amperage 14.5 amps @ 120 VAC ph Accuracy +/- 0.2 ph ph Control range Adjustable 4.5 8.5 ph Weight < 1 lbs Dimensions 3" x

More information

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual

Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual Bante810 Benchtop Dissolved Oxygen Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante810 Benchtop Dissolved Oxygen Meter 1 Introduction Thank you for selecting the Bante810 benchtop dissolved oxygen

More information

Laboratory Standard Operating Procedure: Specimen Preservatives

Laboratory Standard Operating Procedure: Specimen Preservatives I. THIS STANDARD OPERATING PROCEDURE (SOP) IS FOR A: Specific laboratory procedure or experiment Examples: Formalin, Formaldehyde, Caro-Safe, Alcohol. Generic laboratory procedure that covers several chemicals

More information

User s Guide Temperature Sensor Converter TSC-599

User s Guide Temperature Sensor Converter TSC-599 User s Guide Temperature Sensor Converter TSC-599 ILX Lightwave Corporation 31950 Frontage Road Bozeman, MT, U.S.A. 59715 U.S. & Canada: 1-800-459-9459 International Inquiries: 406-556-2481 Fax 406-586-9405

More information

12 Inch Barn Light. Owner s Manual

12 Inch Barn Light. Owner s Manual 12 Inch Barn Light Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions

More information

Standard Operating Procedures (v9 5/1/17)

Standard Operating Procedures (v9 5/1/17) Standard Operating Procedures (v9 5/1/17) Safe Working Practices for Cell Sorting on the Influx Table of Contents I. General Facility Information II. Facility Orientation and Training III. Approval to

More information

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References

User Guide. Pall Laboratory Manifold. For laboratory use. Not for use in a manner other than indicated. Introduction. Regulatory References User Guide Pall Laboratory Manifold For laboratory use. Not for use in a manner other than indicated. Introduction Application and Intended Use The membrane filtration (MF) technique is a method of analyzing

More information

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL

SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL Product Manual MST Portable Air Filtration System SERVICE MANUAL MODEL BA100BMST 100 SCFM PORTABLE AIR PANEL WARNING: Do not attempt to operate this equipment without first reading and understanding the

More information

PPS PORTABLE POWER SUPPLY

PPS PORTABLE POWER SUPPLY PPS User Manual Rev 1-2015 ENG MASTER PPS PORTABLE POWER SUPPLY Disclaimer About ActSafe Safety messages and warnings Product safety System description Pre-use inspection and connection General safety

More information

14500 Coy Drive, Grass Lake, Michigan Isolation Glove Box Instruction Manual

14500 Coy Drive, Grass Lake, Michigan Isolation Glove Box Instruction Manual 14500 Coy Drive, Grass Lake, Michigan 49240 734-475-2200 E-mail: sales@coylab.com www.coylab.com Isolation Glove Box Instruction Manual Index Page Warranty 1 1.0 Warnings 2 2.0 General Overview 3 3.0 Care

More information

Corning Step-R. Repeating Pipettor. Instruction Manual

Corning Step-R. Repeating Pipettor. Instruction Manual Corning Step-R Repeating Pipettor Instruction Manual Table of Contents 1. Introduction... 1 2. Using the Step-R Repeating Pipettor... 1 3. Corning Syringe Tips... 4 4. Recommendations... 5 5. Recalibration...

More information

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions

RAM Operation Manual. Worldwide Manufacturer of Gas Detection Solutions RAM 4021 Operation Manual Worldwide Manufacturer of Gas Detection Solutions TABLE OF CONTENTS RAM 4021 For Your Safety... 2 Description.... 2 Setup Mode.... 2 Lights/Alarms.... 3 Operation.... 4 Calibration....

More information

Digital Melting Point Apparatus

Digital Melting Point Apparatus Digital Melting Point Apparatus Heating Plateau Ramping Start/Stop Plateau set Ramp stop Hold User Guide Version 1.1 Heating Viewing tube Sample Chamber IEC power inlet socket Power on/off Temperature

More information

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor

More information