Automatic balancing valves ASV

Size: px
Start display at page:

Download "Automatic balancing valves ASV"

Transcription

1 Automatic balancing valves ASV ASV-PV ASV-PV ASV-PV ASV-BD ASV-M DN DN 50 DN DN DN Description / Application ASV balancing valves are used for dynamic hydronic balance in heating and cooling systems. Dynamic balancing means: permanent balancing from 0 to 100 % load by controlling the pressure in systems with variable f low. At partial loads, when the f low is decreased by the control valve, pressure limitation is still performed and consequently dynamic balancing is also performed. By using ASV you avoid using complex and time consuming commissioning methods. Dynamic balancing of the system in all loads helps you to save energy and improves climate comfort and control. F low limitation By using a combination of an ASV pressure controller and the terminal s settable unit valve, f low limitation is established. F low limitation for each terminal unit prevents underf lows on distant units and overf lows on others thus allowing efficient pumping. Lower noise emission Differential pressure limitation ensures the pressure over the control valve does not increase at partial loads thus noise emission will be lower. (This is the reason why DIN requires control of differential pressure by partial load.) No balancing method needed F low limitation is achieved by adjusting each hydronic loop separately without inf luencing others, which consequently results in a one time adjusting process. No special balancing method is needed so commisioning costs can be saved. Control valve authority Controlling differential pressure over the control valve means that authority is high which allows an accurate and stable control as well as energy saving. Zone balancing By installing the ASV sets you can divide the piping system into pressure independent zones. This allows a gradual connection of zones to the main system in new constructions or without the need for an additional balancing method when rennovating. There is no need for re-commissioning every time the system is changed because the hydronic balancing is done automatically. ASV-PV valves are settable in different ranges: 5-25 kpa setting is mostly used for radiator application, kpa or kpa setting is used for floor heating, fan coil, chilled beam and f lat station applications, kpa setting is used for f lat station and fan coil, chilled beam application, kpa setting is used for large terminal unit applications (air handling units, fan coils, etc.). By using ASV valves it is possible to optimize the pump head while independent pressure zones allow the authority of the terminal unit s valve to be kept high. SMT/SI VD.A6.E4.12 Danfoss 12/2014 1

2 Description / Application (continuous) ASV balancing valves are designed to guarantee a high quality of automatic balancing by: - a pressure released cone, - an adapted membrane for every valve dimension which provides constant quality performance for all sizes, - spring with linear characteristic that makes setting the required Δp easy. A 90 angle between all service features (shutoff, draining, setting, measuring) allows for easy access under any installation condition. All the above-mentioned features and functions are realized in small built-in dimensions so it is easy to install the ASV even in very limited space. ASV valves are performing pressure control not only at design conditions (100 % load) but also at all partial loads (thus fulfilling the requirements of DIN norms). By controlling pressure at a partial load one can prevent noise problems on thermostatic radiator valves which often occur in unbalanced systems. ASV valves (DN 15-40) are packaged in styropore (EPS) which can be used for insulation at temperatures up to 80 C. An insulation cap is available as an accessory for insulation at higher temperatures (up to 120 C). ASV valves in dimensions DN are supplied with an internal or external thread while DN 50 is supplied with external thread only. If an external thread is chosen, a threaded or weld nipple can be supplied as an accessory. Dimensions DN are supplied as f langed valves. ASV balancing valves have integrated service functions such as shut-off and draining. ASV-PV can be equipped with a nipple for f low measuring. If required measuring nipples can be ordered separately as an accessory and mounted on the valve as follows: on top of drain cock (DN 15-50), on the f lange connection before the valve is filled with water (DN ). ASV-PV valves should be mounted in the return pipe, in combination with partner valves mounted in f low pipe. As a partner valve ASV-M/ BD are recommended for dimensions DN 15 to DN 50 and MSV-F2 for dimensions DN 65 to DN 100. There are two basic configurations when using ASV partner valves (ASV-BD, ASV-M, MSV-F2): - partner valve outside the control loop (Fig. 1). Recommended configuration: it results in best performance since whole controlled pressure range is available to the riser. Flow limitation is done on each terminal unit in the riser (for example, RA-N with presetting on radiator, etc). DN 15 to DN 50: ASV-M or ASV-BD DN 65 to DN 100: MSV-F2, by connecting the impulse tube to down-flow measuring nipple. - partner valve inside control loop (Fig. 2). Offers flow limitation on the riser however part of the controlled pressure range is used by pressure drop on the partner valve ( p i). This is recommended when flow limitation on each terminal unit is not possible. DN 15 to DN 50: ASV-BD. DN 65 to DN 100: MSV-F2, by connecting the impulse tube to up-flow measuring nipple. Fig. 1 Setting of ASV-PV = Δp riser Fig. 2 Setting of ASV-PV = p riser + p i ASV-BD can be used outside or inside the control loop by choice of which measuring nipple is open. To be used outside the control loop, the blue measuring nipple needs to be open. In this position, flow verification can be made (default position). To be used inside the control loop, the red measuring nipple needs to be open. In this position, flow limitation & flow verification can be made. 2 VD.A6.E4.12 Danfoss 12/2014 SMT/SI

3 Description / Application (continuous) Fig. 3 ASV in riser / typical heating application (general example) ASV valves can be used in radiator heating systems to control the differential pressure in risers. To limit the f low for every radiator, the thermostatic radiator valve with pre-setting facilities (feature) is used together with a constant pressure provided by the ASV, thus providing balanced heat distribution. Alternatively the f low in the riser can be limited by using the setting function of the ASV-BD. Controlling differential pressure over the riser means also that the valve authority over the thermostatic radiator valves is high which allows an accurate and stable temperature control and saves energy. Fig. 4 ASV in manifold for f loor heating system ASV valves can also be used in f loor heating systems. To limit the f low for every loop, valves with an integrated f low limiting or pre-setting function should be used together with a constant pressure provided by an ASV-PV valve. Alternatively the f low for the whole manifold can be limited by using the setting function of the ASV-BD. ASV-PV valves can control the differential pressure in several ranges if different pressure is needed. Due to their small dimensions the ASV automatic balancing valves are easy to install in a wall mounted box for f loor heating manifolds. SMT/SI VD.A6.E4.12 Danfoss 12/2014 3

4 Description / Application (continuous) Fig. 5 ASV with fan coil The ASV valves are suitable for use in systems with fan coils, induction devices and air-heaters to secure an automatic hydronic balance by means of differential pressure control in branches or at every coil. Constant differential pressure in combination with pre-set control valves i.e. ASV- BD limits the f low. Fig. 6 F lat station ASV automatic balancing valves can also be used in other applications. For example ASV can be used to prevent noise problems at the thermostatic radiator valves in small systems by controlling the differential pressure. ASV can be used in every application you need a small differential pressure controller, e.g. small f loor manifolds or f lat stations. In buildings equipped with f lat stations ASV valves can be used to provide secure automatic balance by means of differential pressure control in risers/zones. In f lat stations, pressure conditions change when sanitary water heating is taking place in comaparison to the situation when only heating is needed. By using ASV-PV valves the differential pressure is also controlled in these instances. Constant differential pressure in combination with pre-set control valves i.e. ASV-BD limits the f low. 4 VD.A6.E4.12 Danfoss 12/2014 SMT/SI

5 Sizing Thread F lange Q min Q Q 10 kpa Fig. 7 Column diagram for sizing ASV valves at p v = 10 kpa. For different p v values use diagram A and B in Appendix A. We recommend sizing the diameter of ASV-PV valves by using Fig 7. Maximum f low rates are based on 10 kpa differential pressure over the valve which allows effcient pumping and saves energy. After ASV-PV valves have been sized the same dimension of partner valve (ASV-BD / ASV-M / MSV-F2) should be selected. Example: Given: Pipe f low 200 l/h, pipes DN 15 Connection between valve size and pipe size K v values for each dimension were designed to cover a f low range according to VDI 2073 with water velocity of up to 0.8 m/s, at a differential pressure of 10 kpa over the valve. As long as the water velocity in the pipe is between 0.3 and 0.8 m/s, the dimension of the valve should be equal to the pipe dimension. This rule is derived out of the fact that K v values for each dimension have been designed to cover f the low range according to VDI 2073 at a differential pressure of 10 kpa over the valve. Solution: The horizontal line intersects the column for the valve DN 15 which can therefore be selected as the required size. For detailed sizing see examples on pages 14 and 15. For different p v (differential pressure over the valve) see diagrams in Appendix A. SMT/SI VD.A6.E4.12 Danfoss 12/2014 5

6 Ordering ASV-PV balancing valve, includes in the box: 1.5 m impulse tube (G 1/16 A) and drain cock (G 3/4 A) Type DN 15 1,6 k VS p setting range Connection (m 3 /h) (kpa) R p 1/2 Code No. 003L ,5 R p 3/4 003L ,0 R p L ,3 R p 11/4 003L ,0 R p 11/2 003L ,6 Internal thread R p 1/2 003L ,5 ISO 7/1 R p 3/4 003L ,0 R p L ,3 R p 11/4 003L ,0 R p 11/2 003L ,3 R p 11/4 003L ,0 R p 11/2 003L ,6 G 3/4 A 003L ,5 G 1 A 003L ,0 G 11/4 A L ,3 G 11/2 A 003L ,0 External thread ISO 228/1 G 13/4 A 003L ,5 G 1 A 003L ,0 G 11/4 A 003L ,3 G 11/2 A 003L ,0 G 13/4 A 003L ASV-PV balancing valve, inclusive in the box: 2,5 m impulse tube (G 1/16 A) drain cock (G 3/4 A) and adapter 003L Type DN k VS p setting range Connection (m 3 /h) (kpa) External thread ISO 228/1 G 2 1/2 Code No Z Z Z Z ASV-PV balancing valve, inclusive in the box: 2,5 m impulse tube (G 1/16 A), adapter ASV large 003Z and 003L Type DN k VS p setting range Connection (m 3 /h) (kpa) Code No. 003Z Z ,0 003Z Z F lange EN Z ,0 003Z Z Z ,0 003Z VD.A6.E4.12 Danfoss 12/2014 SMT/SI

7 Ordering (continued) ASV-BD shut-off valve, multifunctional partner valve (shut-off, rotating measuring station) Type DN k VS Internal thread (m 3 /h) (ISO 7/1) Code No. 15 3,0 R p ½ 003Z ,0 R p ¾ 003Z ,5 R p 1 003Z R p 1¼ 003Z R p 1½ 003Z R p 2 003Z ASV-M shut-off valve, without measuring nipples Type DN k VS Internal thread External thread Code No. Type (m 3 /h) (ISO 7/1) (ISO 228/1) Code No. 15 1,6 R p ½ 003L ,5 R p ¾ 003L ,0 R p 1 003L ,3 R p 1¼ 003L R p 1½ 003L G 2¼ A 003L Accessories and spare parts Description Comments/connection Code No. Differential pressure measuring connector For drain cock 003L Drain cock For ASV-PV (DN 15-50) 003L Two measuring nipples and one locking plate For ASV-I and ASV-M, rectus type 003L mm measuring nipples, 2 pcs For ASV-BD 4) 003Z Operating handle For ASV-BD 4) 003Z Impulse tube, with O-rings 1.5 m 003L m 003Z m 003L Adapter large ASV 1) G ¼-R ¼; G 1/16 003Z Nipple for connecting impulse tube 2) G 1 16-R ¼ 003L O-ring for impulse tube 3) L Plug for impulse tube connection ASV-M 3) G 1 16 A 003L ) Recommended for use with MSV-F2, connected to measuring hole, it allows connection of impulse tube from ASV while retaining measurement functionality. 2) Recommended for use with MSV-F2, connected to measuring hole. Can also be used for connecting impulse tube directly on the pipe. 3) Set of 10 pieces. 4) for complete range of ASV-BD accessories please refer to MSV-BD datasheet. SMT/SI VD.A6.E4.12 Danfoss 12/2014 7

8 Technical data Type ASV-M/PV ASV-BD Nominal diameter DN Max. pressure 16 (PN 16) 20 bar Test pressure Differential pressure over the valve kpa ) ) Temperature C Material of parts in contact with water Valve body Brass Grey cast iron EN-GJL-250 (GG 25) Cone (ASV-PV) DZR brass Stainless steel DZR brass Ball - Brass / chromium plated Membrane / O-rings Spring Stainless steel - 1) Please note that the maximum admissible differential pressure across the valve 150 kpa should also not be exceeded at partial load. 2) Please note that the maximum admissible differential pressure across the valve 250 kpa should also not be exceeded at partial load. EPDM Design 1. Shut-off knob 2. Differential pressure setting spindle 3. O-ring 4. Reference spring 5. Impulse tube connection 6. Diaphragm element 7. Control diaphragm 8. Pressure-relieved valve cone 9. Valve body 10. Seat n (turns) (kpa) (kpa) (kpa) (kpa) 1) ) DN 32/40 only DN Factory setting p setting range (kpa) kpa Fig. 8 ASV-PV (DN 15-40) ASV-PV is designed to maintain a constant set differential pressure. Via an internal connection and together with the reference spring (4), pressure in the return pipe acts on the underside of the control diaphragm (7) while via an impulse tube (5), pressure in the f low pipe acts on the top of the diaphragm. In this way the balancing valve maintains the set differential pressure. The ASV-PV valves are sold in four different p setting ranges. The valves are factory set to a defined value as described in the Factory seting table in Fig. 8, 9 and 10. Use the following procedure to set the desired differential presure: the setting on ASV-PV can be changed by turning the setting spindle (2). Turning the spindle clockwise increases the setting; turning it counter clockwise reduces the setting. If the setting is not known, turn the spindle fully clockwise. With this the setting the ASV-PV is at maximum value within the setting range. Now turn the spindle a number of times (n) as described in Fig. 8, 9 or 10 until the required differential pressure setting is obtained. 8 VD.A6.E4.12 Danfoss 12/2014 SMT/SI

9 Design (continuous) 1. Shut-off knob 2. Differential pressure setting spindle 3. O-ring 4. Reference spring 5. Impulse tube connection 6. Diaphragm element 7. Control diaphragm 8. Pressure-relieved valve cone 9. Valve body 10. Seat n (turns) (kpa) (kpa) (kpa) (kpa) Factory presetting p setting range (kpa) kpa DN 50 5 Fig. 9 ASV-PV (DN 50) SMT/SI VD.A6.E4.12 Danfoss 12/2014 9

10 Design (continuous) 1. Shut-off knob 2. Differential pressure setting spindle 3. O-ring 4. F lat gasket 5. Reference spring 6. Impulse tube connection 7. Diaphragm element 8. Control diaphragm 9. Pressure-relieved valve cone 10. Valve body 11. Seat 12. Measuring holes-plugged 13. Air-vent DN Factory presetting p setting range (kpa) kpa n (turns) Fig. 10 ASV-PV (DN ) (kpa) (kpa) (kpa) n (turns) (kpa) (kpa) (kpa) VD.A6.E4.12 Danfoss 12/2014 SMT/SI

11 Design (continuous) 1. Valve body 2. Ball 3. Ball seat 4. Supporting screw 5. Throttle bush 6. Closing bush 7. Valve top 8. Spindle head 9. Spindle 10. Rotation lock 11. Drain cock 12. Handle 13. Rotating measuring station 14. Measuring nipple 15. Impulse tube connection Fig. 11 ASV-BD DN Partner valves ASV-BD/M can be used together with the ASV-PV automatic balancing valves to control differential pressure in the risers. ASV-BD is a combined pre-setting and shut off valve with a range of unique features: high kv values for small pressure losses partner valve position inside or outside control loop (see page 2 for details), selectable even after the valve is already installed and under pressure. Numeric pre-setting scale, visible from multiple angles Easy locking of pre-setting Rotating measuring station with built-in measuring nipples for 3 mm needles Built-in drain cock with separate f low/return draining Removable hand wheel for easy mounting. Open-closed colour indicator. Impulse tube connection The impulse line must be connected to the impulse tube connection piece (15). In working position, one of the measuring nipples needs to be open while the other needs to be closed. There are two possible configurations, with partner valve inside or outside the control loop. This can be chosen by impulse tube connection side: - Partner valve outside the controlled loop: open the outlet measuring nipple (blue marking). ASV-BD needs to be set to the max setting (fully open). F low verification is possible. - Partner valve inside controlled loop: open inlet measuring nipple (red marking). F low limitation with flow verification is possible. Note: Default position is open inlet measuring nipple (blue marking). F low limitation Use the following procedure: 1. When the valve is open the lock is released. (An Allen key can also be used). 2. The handle pops up and the required f low setting may be set. 4. Lock the setting by pressing the handle until it clicks. 5. If needed, f low can be measured using PFM 100 or another brand of measuring instrument. F low verification (in case ASV-BD is used outside controlled loop) Use the following procedure: 1. ASV-BD setting is at maximum value. 2. F low can be measured using PFM 100 or another brand of measuring instrument. 3. If the pressure drop across the valve is too low for reliable f low measurement, ASV-BD needs to be set to the lower setting to achieve high enough pressure drop across the valve. 4. After flow measurement, return the setting to maximum value and lock it by pressing the handle until it clicks. Draining Use the following procedure to drain: 1. Close the open measuring nipple. 2. Remove the impulse tube. 3. Remove the adapter. Make sure the drain cock is secured with a spanner when the adapter is removed. 4. The blue nipple opens the outlet while the red measuring nipple opens the inlet. Make sure not to use more than a max. 3 turns. The drain tap and nipples can rotate to any position. Note: when draining, always keep same or higher static pressure on upper part of ASV-PV membrane. Therefore, always drain from the return pipe first and remove the impulse tube only after the return pipe is empty. If draining is done from flow pipe first, the membrane can be damaged. SMT/SI VD.A6.E4.12 Danfoss 12/

12 Design (continuous) 1. Shut-off knob 2. Shut-off spindle 3. O-rings 4. Valve cone 5. Seat 6. Valve body ASV-M is designed to shut-off the pipe f low. ASV-M has a connection for an impulse tube to ASV-PV. It can be equipped with nipples for f low measuring (these are sold separately as accessories). Fig. 12 Port A Port B ASV-M 12 VD.A6.E4.12 Danfoss 12/2014 SMT/SI

13 Sizing-design examples Δp a = Δp m + Δp r + Δp v Δp v Δp m Δp r Δp a Pressure drop across ASV-PV Pressure drop across ASV-M valve Necessary pressure for the riser Available pressure for the riser Fig Example Given: Radiator system with thermostatic radiator valves with pre-setting function. Desired f low for the riser (Q):... 1,500 l/h Minimal available pressure for that riser (Δp a)...70 kpa Estimated pressure drop over the riser at the desired f low (Δp r)...20 kpa Wanted: - Valve type - Valve size Since radiator valves has pre-setting function ASV-M is selected. Since desired pressure drop over the riser is 20 kpa ASV-PV is selected. ASV-PV should control 20 kpa pressure over the riser that means that 50 kpa out of 70 will be disposed over two valves. Δp v + Δp m = Δp a Δp r = = 50 kpa We presume that dimension DN 25 is the right dimension for this example (please mind that both valves should be of the same dimension). As ASV-M DN 25 is to be fully open pressure drop is calculated by following equation: 2. Example Correcting the f low with the differential pressure setting. Given: Measured f low for the riser Q 1...1,500 l/h ASV-PV valve s setting Δp r kpa Wanted: New valves setting to increase the f low for 10%, Q 2 = 1,650 l/h. Setting on the ASV-PV valve: When required, setting of the control pressure can be adjusted between 5 to 25 kpa or 20 to 40 kpa). By increasing/decreasing the setting it is possible to adjust the f low through the riser, terminal or similar. (100% increase of control pressure will increase the f low by 41%) p = 0.20 = Q = p1 Q If we increase the setting to 24 kpa f low will be increased to 10 % (1,650 l/h). 2 2 Q 1.5 pm = = = 0.14bar= 14 kpa Kv or by reading from diagram in Appendix A, fig. D as follows: Draw horizontal line from 1.5 m 3 /h (~1,500 l/h) trough the line that depicts dimension DN 25. From the intersection draw vertical line to read that pressure drop is 14 kpa. Pressure drop over ASV-PV valve is therefore: Δp v= (Δp a-δp r) Δp m = 50 kpa 14 kpa = 36 kpa as can be read from diagram in Appendix A, Fig. A. SMT/SI VD.A6.E4.12 Danfoss 12/

14 Sizing-design examples (continuous) 3. Example Limiting the f low with ASV-BD valve Given: Desired f low for the branch (Q): l/h ASV-PV and ASV-BD (DN 25) Setting on the ASV-PV valve (Δp o)...10 kpa Estimated pressure drop over the riser at desired f low (Δp r)... 4 kpa Required: Setting of the ASV-BD valve to achieve desired f low Solution: When required the ASV-BD can be adjusted to perform a flow limitation function. ASV-BD namely is inside the control loop of the pressure controller therefore adjusting the ASV BD would result in adjusting of the f low limitation. (The general rule is that a 100% increase of the kv value will increase the f low by 100%) k Q Δp v = 0.06 v = = Δp a = Δp i + Δp r + Δp v Δp v Pressure drop across ASV-PV valve Δp i Pressure drop across ASV-BD valve Δp o Pressure drop in the riser including ASV-BD Δp a Available pressure for the riser Δp r Pressure drop in the riser excluding ASV-BD Fig m The result can be seem in the diagram in Appendix A, Fig. C. With a desired f low pressure drop over the entire branch of 4 kpa. Without using ASV-BD, the f low through the branch when the control valve is fully open will be 58% higher thus causing overf low (4 kpa allows 880 l/h, while 10 kpa allows 1390 l/h). By adjusting the ASV-BD DN 25 to 90% k v value (3.6 m 3 /h) we will limit the f low to 880 l/h as desired. This value is obtained by the following calculation: Δp i = Δp o Δp r = 10 4 = 6 kpa. 3 h Δp a = Δp i + Δp r + Δp v Δp v Pressure drop across ASV-PV valve Δp i Pressure drop across MSV-F2 Δp o Pressure drop across the riser including MSV-F2 Δp a Pressure drop across the riser Δp r Pressure drop in the riser excluding MSV-F2 Fig Example F lat station application Given: No. of f lat stations connected to one riser... 5 Heating power of each station...15 kw Sanitary water heating on each station...35 kw Simultaneous factor (source TU Dresden) Desired f low for branch (Q):... 6,400 l/h Minimal available pressure for that riser ( p a)...80 kpa Estimated pressure drop over the riser at the desired f low ( p o)...50 kpa Wanted: - Valve type - Valve size For maximum f low calculation in the riser, simultaneous factors are used since sanitary water consumption is a temporary occurrence and is not used simultaneously in all apartments/f lats. Since water f low through the heat exchanger while heating sanitary water is not controlled, the maximum f low needs to be limited as well. As the desired pressure drop over the riser is 50 kpa ASV-PV with a range between 0.35 and 0.75 bar (35 and 75 kpa) is selected. Since 80 kpa is available for the riser, the p v shall be 30 kpa. p v = p a p o = = 30 kpa k Q Δp 6.4 v = = = v m /h For 6,400 l/h a DN 50 size valve is selected as calculated above or by looking at the diagram in Appendix A, fig. B. The f low through the riser can be limited with an ASV-BD or MSV-F2 if needed. 14 VD.A6.E4.12 Danfoss 12/2014 SMT/SI

15 Measurement of f low and differential pressure ASV-BD (needle type) is equipped with two measuring nipples so that the differential pressure across the valve can be measured using Danfoss measuring equipment or any other measuring device. Using the pressure drop graph for ASV-BD (Appendix A, fig C), the actual differential pressure across a valve can be converted to actual f low. Note: When measuring the f low, all radiator valves must be fully open (nominal f low). Measurement of differential pressure (Δp r) across riser. Fit a measuring connector (Danfoss code no. 003L814300) on the ASV-PV balancing valve drain cock (DN 15-50) or threaded connection closer to the terminal unit (TU). Measurements must be taken between the measuring nipple at ASV-BD/ASV-M/MSV-F2 valve port B and the measuring connector on the ASV-PV. Installation ASV-PV must be installed in the return pipe with f low in the direction of the arrow on the valve body. Partner valves (ASV-M/BD, MSV-F2 must be installed in the f low pipe, with f low in the direction of the arrow on the valve body. The impulse tube must be installed between partner valve and ASV-PV. The impulse tube must be f lushed through before installation. ASV-PV and ASV-BD must in addition be installed as determined by installation conditions. Pressure testing Max. test pressure bar When pressure testing the system you must ensure that both sides of the membrane have the same static pressure to prevent damage to the pressure controller. This means that the impulse tube must be connected and any needle valves must be open. If ASV-PV DN is installed in combination with ASV-M both valves must be open or closed (both valves must be in the same position!). If ASV PV DN is installed in combination with ASV-BD both valves must be open. During this operation (closing or opening the valves) please make sure that there is never lower pressure on the upper side of the membrane to prevent damaging it. Starting During system start opening the shut-off on the ASV-PV and partner valve (please ensure that there is the same static pressure on both sides or higher pressure on the upper side of the membrane). If filling is managed by opening the ASV-PV and partner valve, please make sure there is a pressure on the upper side of the membrane by opening the partner valve before the ASV-PV is opened. SMT/SI VD.A6.E4.12 Danfoss 12/

16 Dimensions ASV-PV DN L1 L2 L3 H1 H2 D1 D2 S a b c mm ISO 7/1 ISO 228/ Rp ½ G ¾ A Rp ¾ G 1 A Rp 1 G 1¼ A Rp 1¼ G 1½ A G ¾ A 245 1) Rp 1½ G 1¾ A 250 1) 1) kpa setting range Fig VD.A6.E4.12 Danfoss 12/2014 SMT/SI

17 Dimensions (continuous) ASV-PV p setting range L1 L2 L3 H1 H2 D1 D2 b c DN kpa mm ISO 228/ G 21/2 G 3/4 A ASV-PV L1 H1 H2 D1 D2 D3 DN mm Fig. 17 SMT/SI VD.A6.E4.12 Danfoss 12/

18 Dimensions (continuous) H ASV-BD DN L H S a mm ISO 228/ G ½ G ¾ G G 1¼ G 1½ G 2 a L G1/4 S a ASV-M DN L1 L2 L3 H1 H2 D1 S a b mm ISO 7/1 ISO 228/ Rp ½ G ¾ A Rp ¾ G 1 A Rp 1 G 1¼ A Rp 1¼ G 1½ A Rp 1½ G 1¾ A G 2¼ A Fig VD.A6.E4.12 Danfoss 12/2014 SMT/SI

19 Appendix A-Sizing diagram Fig. A - Sizing diagram ASV-P/PV DN SMT/SI VD.A6.E4.12 Danfoss 12/

20 Appendix A-Sizing diagram Fig. B - Sizing diagram ASV-PV DN VD.A6.E4.12 Danfoss 12/2014 SMT/SI

21 Appendix A-Sizing diagram Fig.C - Sizing diagram ASV-BD DN SMT/SI VD.A6.E4.12 Danfoss 12/

22 Appendix A Fig. E -Pressure drop over ASV-M valves, DN VD.A6.E4.12 Danfoss 12/2014 SMT/SI

23 Fittings Description Fittings For valves with external thread Danfoss offers threaded or welded tailpieces as accessory. Materials Nut...brass Tailpiece welded...steel Tailpiece threaded...brass Ordering Note: ASV-PV DN 50 (2 1/2 ) and ASV-M DN 50 (2 1/4 ) have different size connections. 1) To use with ASV-PV DN 50 valves. 2) To use with ASV-M DN 50 valves. Fittings Type Comments to pipe to valve Code No. R 1/2 DN Z R 3/4 DN Z Tailpiece threaded (1 pcs.) R 1 DN Z R 1 1/4 DN Z R 2 DN 50 (2 1/4 ) 003Z ) DN 50 (2 1/2 ) 003Z ) ASV-PV tender text 1. The pressure differential control valve should be available in the range from DN The pressure differential control should be based on integrated membrane element. 3. The range of settable differential pressure should be 5-25kPa, 20-40kPa or kpa in dimension DN and kpa, kpa or kpa in dimension DN For radiator applications a differential pressure of 5-25kPa is recommended. 4. The setting of the differential pressure should be with a hexagon key (DN 15-40) or, if by socket it should be hidden. 5. The differential pressure setting should be linear (1 turn 1 kpa or 1 turn 2 kpa depending on the valve size). 6. Shut off service function should be possible by a handle/knob. 7. Drain function is needed in range DN Temperature range should be C at DN and C at DN Nominal pressure should be 16 bar with test pressure 25 bar. 10. The pressure differential control valve package in DN range needs to contain an impulse tube (min. 1.5 m) and EPS valve insulation up to min. 80 C. Nominal diameter: Connection: Adjustment range from - to kpa Produced by: Danfoss Type: ASV-PV Ordering no.: 003L SMT/SI VD.A6.E4.12 Danfoss 12/

24 24 VD.A6.E4.12 Produced by Danfoss A/S 12/2014

Automatic balancing valves ASV

Automatic balancing valves ASV Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance in heating and

More information

Automatic balancing valves ASV

Automatic balancing valves ASV Automatic balancing valves ASV ASV-P ASV-PV ASV-PV ASV-PV ASV-BD ASV-I ASV-M 15-40 15-40 50 65-100 15-50 15-50 15-50 Description / Application ASV balancing valves are used for dynamic hydronic balance

More information

Automatic balancing valves

Automatic balancing valves Automatic balancing valves ASV DN 15-50 (4th gen.) ASV-PV ASV-BD ASV-M DN 15-50 DN 15-50 DN 15-50 Description ASV whiteboard animation ASV valves are automatic balancing valves. Together with Danfoss presetting

More information

Upgradable balancing valves USV

Upgradable balancing valves USV Upgradable balancing valves USV Application / Description USV-I USV-M USV valves are designed for manual hydronic balancing of heating and cooling systems. USV-I (red knob) is used together with USV-M

More information

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN

Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN Data sheet Automatic Balancing Valve Pressure difference controller with integrated flow limiter AB-PM DN 40-100 Description AB-PM is ideal for staged installation and commissioning AB-PM is a combined

More information

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting

Differential pressure controller (PN 16) AHP - return mounting, adjustable setting Data sheet Differential pressure controller (PN 16) AHP - return mounting, adjustable setting Description DN 15-40 DN 50 DN 65-100 AHP is a self-acting differential pressure controller primarily for use

More information

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting

Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting Data sheet Differential pressure controller (PN 16) AVPL - return mounting, adjustable setting Description It can be used on primary side of house substations for smaller systems such as one and two-family

More information

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet

V5001P. Kombi-Auto Differential Pressure Control Valve. Product specification sheet V5001P Kombi-Auto Differential Pressure Control Valve Product specification sheet Content Application...1 Special Features...1 Valve Efficiency...1 Technical Data...2 Construction...2 Materials...2 Method

More information

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting

Differential pressure controller (PN 16) AVPL return mounting, adjustable setting Data sheet Differential pressure controller (PN 16) AVPL return mounting, adjustable setting Description It can be used on primary side of house substations for smaller systems such as one and two-family

More information

Pressure independent balancing and control valve AB-QM DN

Pressure independent balancing and control valve AB-QM DN Data sheet Pressure independent balancing and control valve AB-QM DN 10-250 The AB-QM valve equipped with an actuator is a control valve with full authority and an automatic balancing function / flow limitation.

More information

Seated valves VRB 3, VRG 3

Seated valves VRB 3, VRG 3 Data sheet Seated valves VRB 3, VRG 3 Description VRB, VRG valves provide a quality, cost effective solution for most water and chilled applications. These valves may be used with glycol concentrations

More information

AVP-F. p setting range (bar) Code No. 003H6200

AVP-F. p setting range (bar) Code No. 003H6200 Data sheet Differential pressure controller (PN 16) AVP - return and flow mounting, adjustable setting AVP-F - return mounting, fixed setting Description The controller has a control valve, an actuator

More information

Differential Pressure Control Valve. Passim

Differential Pressure Control Valve. Passim Differential Pressure Control Valve Passim 2 Table of contents Chapter Nexus Valve Passim DN 15-50, DN 65-80 1. Safety instructions 4 1.1 Rules/regulations 4 1.2 Intended use 5 1.3 Initial operation 5

More information

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Dynamic Valve Type RA-DV Pressure Independent Radiator Valve Application RA-DV straight version RA-DV is a series of pressure independent radiator valves, designed for use in 2-pipe heating systems together

More information

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions

Versions. Benefits. Balancing DN15-32 DN40 DN50 DN15, DN20, DN25, DN32, DN40, DN50. Dimensions Ballorex Delta Description The Ballorex Delta is a differential pressure control valve used in hydronic heating or cooling systems. By ensuring a constant differential pressure across motorized or static

More information

AVPQ/AVPQ-F, PN 16. Application

AVPQ/AVPQ-F, PN 16. Application Data sheet Differential pressure and flow control AVPQ/AVPQ-F, PN 16 Application AVPQ is a self-acting differential pressure and flow control primarily for use in district heating systems. AVPQ closes

More information

STAP. Differential pressure controller DN 15-50

STAP. Differential pressure controller DN 15-50 Differential pressure controller 15-50 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE is a high-performing differential pressure controller that keeps the

More information

Balancing Valves. Applications/ Features: Ordering Information: Accessories:

Balancing Valves. Applications/ Features: Ordering Information: Accessories: Applications/ Features: Danfoss MSV balancing valves are designed to provide terminal or circuit flow balance in hydronic heating or cooling systems. Each valve provides a high level of balancing accuracy

More information

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting

Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Data sheet Differential pressure and flow controller (PN 16) AVPQ - return mounting, adjustable setting Description AVPQ is a self-acting differential pressure and flow controller primarily for use in

More information

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Data sheet Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange Description VL 2 VL 3 VL 2 and VL 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Data sheet Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange Description VF 2 VF 3 VF 2 and VF 3 valves provide a quality, cost effective solution for most water and chilled applications.

More information

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16

Differential pressure control and flow limiter AVPB/AVPB-F, PN 16 Data sheet Differential pressure control and flow limiter AVPB/AVPB-F, PN 16 Application AVPB is a self-acting differential pressure control and flow limiter primarily for use in district heating systems.

More information

STAP. Differential pressure controller DN

STAP. Differential pressure controller DN STAP Differential pressure controller DN 65-100 Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING ADVANTAGE The flanged STAP is a high-performing differential pressure

More information

RA-N radiator valves with integrated presetting and self-sealing tailpiece

RA-N radiator valves with integrated presetting and self-sealing tailpiece Data sheet RA-N radiator valves with integrated presetting and self-sealing tailpiece EN 215 Application Straight version Angle version Horizontal angle version All RA-N valve bodies can be used together

More information

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting

Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Differential pressure controller (PN 25) AVP - return and flow mounting, adjustable setting Description AVP(-F) is a self-acting differential pressure controller primarily for use in district heating systems.

More information

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass

Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass Multifunctional Thermostatic Circulation Valve MTCV - Lead free brass Introduction Fig. 1 Basic version - A Fig. * Self-acting version with automatic disinfection function - B * thermometer is an accessory

More information

differential pressure regulating valve - threaded

differential pressure regulating valve - threaded 140-142 differential pressure regulating valve - threaded Introduction Differential pressure regulating valves (DPRV) maintain the differential pressure across a circuit or sub-branch at a set differential

More information

VZL valve - 2/3/4-way

VZL valve - 2/3/4-way VZ valve - 2/3/4-way Description Stem extension plug VZ 2 VZ 3 VZ 4 VZ valves provide a high quality, cost effective solution for the control of hot and/or chilled water for fan coil units, small reheaters,

More information

Pressure reduction controller (PN 16, 25, 40)

Pressure reduction controller (PN 16, 25, 40) Pressure reduction controller (PN 16, 25, 40) AFD / VFG 2( - for water AFD / VFGS 2 - for steam Description The controller has a control valve, an actuator with one control diaphragm and a spring for pressure

More information

Two-port valves, male threaded, PN25

Two-port valves, male threaded, PN25 4 379 Two-port valves, male threaded, PN25 VVG55... Two-port valves, externally threaded, PN25 Bronze Rg5 DN15... 25 mm (½"... 1") k vs 0.25... 6.3 m 3 /h Stroke 5.5 mm Suitable for type SQS35... or SQS65...

More information

HERZ-Motorised flow controler

HERZ-Motorised flow controler HERZ-Motorised flow controler Control and regulating valve Data sheet 46, Issue 214 Dimensions in mm 4 close dimension 9,35 M DN G H1 H2 H2 + Actuator B1 B2 1 2 M 1 46 11 15 3/4 G 66 59 73 134 49 63 48

More information

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G Data sheet Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G Application RA2000 013G2910 Built-in sensor RA2000 013G2920 tamperproof RA2000 013G5062 remote temperature adjuster

More information

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40

Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40 Product Sheet Pre-Fabricated Flushing Bypass Assembly for Terminal Applications Mini-Flush 40 Description Miniflush 40 is a pre-fabricated, flushing bypass arrangement for balance, control, isolation,

More information

Pressure Independent Control Series

Pressure Independent Control Series Document No. 155-522 Pressure Independent Control Series Two-Way Cast Iron Flanged Bodies, ANSI 125 and 250 Description Siemens Pressure Independent Control Valves integrate three functions into a single

More information

2-port and 3-port valves PN 16

2-port and 3-port valves PN 16 OEM 2-port valves VVP459.10-0.63 to VVP459.25-6.3 3-port valves VXP459.10-0.63 to VXP459.25-6.3 3-port valves with bypass VMP459.10-0.63 to VMP459.20-4 2-port valves VVP459.25-6.3 to VVP459.40-25 3-port

More information

V5434T/H THREE-WAY ROTARY VALVE PN10 AND H-EXTENSION

V5434T/H THREE-WAY ROTARY VALVE PN10 AND H-EXTENSION V544T/H THREE-WAY ROTARY VALVE PN10 AND H-EXTENSION FEATURES PRODUCT DATA Chrome-plated plug for long life-span Optimized characteristics for supply water temperature control All around changeable rotary

More information

2-port seat valves PN25 with externally threaded connections

2-port seat valves PN25 with externally threaded connections 4 379 2-port seat valves PN25 with externally threaded connections VVG55.. Valve body bronze CC491K (Rg5) DN 15...25 (½...1 ") kvs 0.25...6.3 m3/h Stroke 5.5 mm Sets of ALG.. with threaded and ALS.. with

More information

STAP. Differential pressure controllers DN , ANSI flanges

STAP. Differential pressure controllers DN , ANSI flanges STAP Differential pressure controllers DN 65-100, ANSI flanges IMI TA / Differential pressure controllers / STAP STAP The flanged STAP is a high-performing differential pressure controller that keeps the

More information

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G

Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G Data sheet Radiator thermostats type RA2000, valve bodies type RA-FN (series D) and RA-G EN 215 Application RA2000 013G2910 Built-in sensor RA2000 013G2920 tamperproof RA2000 013G5062 remote temperature

More information

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX

Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX Chrome plated radiator valves type RA-NCX and lockshield valves type RLV-CX Application RA-NCX angle RA-NCX straight RA-NCX left angle RLV-CX straight RLV-CX angle RA-NCX and RLV-CX is a series of chrome

More information

STAD. Balancing valves DN 15-50

STAD. Balancing valves DN 15-50 STAD Balancing valves DN 15-50 IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for use on the

More information

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange

Pressure balanced valves (PN 25) VM 2 2-way valve, external thread VB 2 2-way valve, flange Data sheet Pressure balanced valves (PN 25) 2-way valve, external thread VB 2 2-way valve, flange Description VB 2 and VB 2 are two-way valves designed to work with Danfoss electric actuators AMV(E) 0,

More information

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread

2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread Data sheet 2 - way valve (NO) for steam, pressure relieved (PN 25) VGS - external thread Description VGS is pressure relieved 2-way normally open (NO) valves for steam, designed to be combined with: -

More information

STAP. Differential pressure controllers DN , ANSI fl anges

STAP. Differential pressure controllers DN , ANSI fl anges STAP Differential pressure controllers DN 65-100, ANSI fl anges IMI TA / Differential pressure controllers / STAP STAP The fl anged STAP is a high-performing differential pressure controller that keeps

More information

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1)

Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2(1) AFPB-F / VFQ 2(1) Data sheet Differential pressure controller with flow limitation (PN 16, 25, 40) AFPB / VFQ 2( AFPB-F / VFQ 2( return mounting, adjustable setting return mounting, fixed setting Description The controller

More information

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control

TA-Modulator. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control TA-Modulator Combined control & balancing valves for small terminal units Pressure independent balancing and control valve for modulating control IMI TA / Control valves / TA-Modulator TA-Modulator The

More information

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits.

Technote. Frese PVS - Dynamic Pressure and Flow Regulation Valve. Application. Features. Benefits. Page 1 of 15 - Dynamic Pressure and Regulation Valve Application system can be installed in domestic and commercial heating and cooling systems. system is a dynamic valve arrangement designed to regulate

More information

STAD-C. Balancing valves DN 15-50

STAD-C. Balancing valves DN 15-50 STAD-C Balancing valves 15-50 IMI TA / Balancing valves / STAD-C STAD-C The STAD-C balancing valve has been specially developed for use in indirect cooling systems but performs just as effectively in refrigerated

More information

STA. Double regulating valves DN 15-50

STA. Double regulating valves DN 15-50 STA Double regulating valves DN -0 IMI TA / Balancing valves / STA STA The STA double regulating valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for

More information

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves

STAD-D. Balancing valves Balancing valve for domestic water systems, DN Balancing valves STAD-D Balancing valves Balancing valve for domestic water systems, DN 15-50 Balancing valves IMI TA / Balancing valves / STAD-D STAD-D The STAD-D balancing valve delivers accurate hydronic performance

More information

Presetting Valve Type RA-N with Flange Connection

Presetting Valve Type RA-N with Flange Connection Data Sheet Presetting Valve Type RA-N with Flange Connection The setting options range from kv = 0.08-0.67 m3/h. Kvs = 0.88 m3/h Application The valve is deliveres assembled including mounted air ventilation

More information

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com

STAD Series. Balancing and control valves. Technical Data Sheet. WattsIndustries.com STAD Series Balancing and control valves Technical Data Sheet WattsIndustries.com Description STAD Series variable-orifice threaded valves are designed for flow control and monitoring in climate control

More information

STAD. Balancing valves DN (MD60, MD61, MD62)

STAD. Balancing valves DN (MD60, MD61, MD62) STAD Balancing valves DN 15-50 (MD60, MD61, MD62) IMI TA / Balancing valves / STAD STAD The STAD balancing valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited

More information

DRU/HE THREE-WAY ROTARY VALVE PN10 AND HE25/32 EXTENSION

DRU/HE THREE-WAY ROTARY VALVE PN10 AND HE25/32 EXTENSION DRU/HE THREE-WAY ROTARY VALVE PN AND HE/ EXTENSION FEATURES PRODUCT DATA Chrome-plated plug for long life-span Optimized characteristics for supply water temperature control All around changeable rotary

More information

Seated valve for steam (PN 25)

Seated valve for steam (PN 25) Data sheet Seated valve for steam (PN 25) VFS 2 Two way valve, flange Description VFS 2 valve is a range of 2 port flanged valve for chilled water, PHW, MPHW, HPHW (low, medium or high pressure hot water)

More information

Differential Pressure Control Valve (DPCV)

Differential Pressure Control Valve (DPCV) Differential Pressure Control Valve (DPCV) PATENTED Technical Data and Installation Instructions Page 1 V2 The modulating valves ART 241 balance and control the differential pressure (DPCV) automatically

More information

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems.

STV / STVL. Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems. Applications/ Features: Danfoss STV series of balancing valves provide testing and balancing of circuit flow for hydronic heating or cooling systems. STV valves provide a high level of balancing accuracy

More information

STA. Double regulating valves DN 15-50

STA. Double regulating valves DN 15-50 STA Double regulating valves DN 15-50 IMI TA / Balancing valves / STA STA The STA double regulating valve delivers accurate hydronic performance in an impressive range of applications. Ideally suited for

More information

2-port and 3-port seat valves, PN16

2-port and 3-port seat valves, PN16 s 4 47 VVI47 VXI47 CVTIX 2-port and 3-port seat valves, PN6 with internally threaded connections VVI47.. VXI47.. ronze valve body CC49K (Rg5) DN 5...5 k vs 2.5...4 m 3 /h Internally threaded connections

More information

Seated valve for steam (PN 25) VFS 2 2-way valve, flange

Seated valve for steam (PN 25) VFS 2 2-way valve, flange Data sheet Seated valve for steam (PN 25) VFS 2 2-way valve, flange Description VFS 2 valve is a range of 2 port flanged valve for chilled water, PHW, MPHW, HPHW (low, medium or high pressure hot water)

More information

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV)

TA-COMPACT-P. Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV) Combined control & balancing valves for small terminal units Pressure independent balancing and control valve (PIBCV) IMI TA / Control valves / The pressure independent balancing and control valve ensures

More information

ART24 Differential Pressure Control Valve (DPCV)

ART24 Differential Pressure Control Valve (DPCV) ART24 Differential Pressure Technical Data and Installation Instructions Page 1 PN 16 Main features: ART24 is used for balancing the flow in cooling, heating and domestic water systems. ART24 is a differential

More information

TRV-2, TRV-2S. Thermostatic radiator valves With presetting

TRV-2, TRV-2S. Thermostatic radiator valves With presetting TRV-2, TRV-2S Thermostatic radiator valves With presetting IMI EIMEIER / Thermostatic heads and Radiator valves / TRV-2, TRV-2S TRV-2, TRV-2S Thermostatic radiator valve primary for radiators in heating

More information

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics

TA-FUSION-P. Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics TA-FUSION-P Combined control & balancing valves Pressure independent combined balancing and control valves with independent EQM characteristics IMI TA / Control valves / TA-FUSION-P TA-FUSION-P These innovative

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 40 2-Port Seat Valves with Flange, PN 6 VVF4... Grey cast iron EN-GJL-250 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SQX- electromotoric or SKD...-, SKB...- or SKC...- electrohydraulic

More information

Rotary valves HRB 3, HRB 4

Rotary valves HRB 3, HRB 4 Data sheet Rotary valves HRB 3, HRB 4 Description HRB rotary valves can be used in combination with electric actuators AMB 162 and AMB 182. Features: Lowest leakage in class Unique position indicator (visible

More information

Overview of types. T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2)

Overview of types.   T5-R B2/R B2 en v Subject to changes 1 / 4. k vs (Sequence 2) Technical data sheet R3015-..-..-B2 / R3020-..-..-B2 Characterised control valves, 6-way, with internal threads Two sequences (cooling/heating) With a rotary actuator 90 Water-side switching or modulating

More information

STAG. Balancing valves Balancing valve with grooved ends DN

STAG. Balancing valves Balancing valve with grooved ends DN STAG Balancing valves Balancing valve with grooved ends DN 65-300 IMI TA / Balancing valves / STAG STAG A grooved end, ductile iron balancing valve that delivers accurate hydronic performance in an impressive

More information

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits.

Technote. Frese PV-SIGMA Compact Dynamic Pressure and Flow Regulation. Description. Application. Operation. Features. Benefits. Page 1 of 15 Dynamic Pressure and Regulation Description The system is a dynamic valve arrangement designed to regulate flow and differential pressure. Application The system can be installed in both domestic

More information

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils

Three-port valves. Special versions with special stem sealing gland for: High temperature hot water C Thermo oils 4 440 Three-port valves with flange, PN6 VXF4... Three-port valves with flange, PN6 Can be used as mixing or diverting valves Grey cast iron GG-25 DN5...50 mm k vs.9...300 m 3 /h Stroke 20 or 40 mm Can

More information

Technote. Frese ALPHA cartridges. Application. Features. Benefits.

Technote. Frese ALPHA cartridges. Application. Features. Benefits. Page 1 of 7 Application is used in heating and cooling systems for the distribution of flow in various sections of the system. The dynamic balancing valve ensures easy and reliable balancing of the system,

More information

Pressure balanced valves (PN 25)

Pressure balanced valves (PN 25) Data sheet Pressure balanced valves (PN 25) 2-way valve, external thread VB 2 2-way valve, flange Description VB 2 and VB 2 are two-way valves designed to work with Danfoss electric actuators AMV(E) 10,

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

TBV-CM. Combined control & balancing valves for small terminal units For modulating control

TBV-CM. Combined control & balancing valves for small terminal units For modulating control TBV-CM Combined control & balancing valves for small terminal units For modulating control IMI TA / Control valves / TBV-CM TBV-CM Designed for use in terminal units in heating and cooling systems, the

More information

Self-operated Pressure Regulators for special applications

Self-operated Pressure Regulators for special applications Self-operated Pressure Regulators for special applications Type 2357-31 Pressure Build-up Regulator with safety function and integrated excess pressure valve Application Pressure regulators for cryogenic

More information

BTV. Internally threaded 2-way control valve. Flow characteristics. Function

BTV. Internally threaded 2-way control valve. Flow characteristics. Function Internally threaded 2-way control valve The valves are designed for control of hot, cold or glycol-mixed water in heating and ventilation systems. They are pressure balanced (from DN20-50, not DN15) and

More information

Ballorex Dynamic Description. Versions. Benefits. Balancing

Ballorex Dynamic Description. Versions. Benefits. Balancing Ballorex Dynamic Description The Ballorex Dynamic valve is a combined pressure independent flow limiter and control valve which maintains a constant flow independently of pressure changes in heating or

More information

Two-port seat valves

Two-port seat valves 4 345 Two-port seat valves with flange, PN16 VVF45... Two-port seat valves with flange, PN16 Spheroidal cast iron GGG-40 DN50...150 mm k vs 19...300 m 3 /h Stroke 20 or 40 mm Can be equipped with actuators

More information

2-Port Seat Valves with Flange, PN 16

2-Port Seat Valves with Flange, PN 16 4 45 2-Port Seat Valves with Flange, PN 6 VVF45... dular cast iron EN-GJS-400-5 valve body DN 50...50 k vs 9...00 m /h Can be equipped with SKB...- or SKC...- electrohydraulic actuators Use For use in

More information

Pressure Reducing Valve DMV 755

Pressure Reducing Valve DMV 755 Pressure Reducing Valve DMV 755 Nominal size DN 10 50 Nominal size 3/8 2 Nominal pressure PN 10 bar Features pressure setting range 1 to 9 bar control valve for reliable reduction of system pressures to

More information

Function. brass EN CW617N brass EN CW617N brass EN CW614N. brass EN CW614N brass EN CW617N EPDM

Function. brass EN CW617N brass EN CW617N brass EN CW614N. brass EN CW614N brass EN CW617N EPDM Balancing valves series - cert. n 000 ISO 900 ALEFFI 0/0 GB Function Balancing valves are hydraulic devices that can precisely regulate the flow rate of the fluid that supplies a system s emitters. Hydraulic

More information

VARIABLE ORIFICE BALANCING VALVE PN 25 TECHNICAL DATA SHEET. Approved by*: Main features:

VARIABLE ORIFICE BALANCING VALVE PN 25 TECHNICAL DATA SHEET. Approved by*: Main features: VARIABLE ORIFICE BALANCING VALVE PN 787 Main features: Technical data: Cim 787 is used for balancing the flow in cooling, heating and domestic water systems. Cim 787 is a combined manual presetting valve

More information

V5012C Kombi-DP Diaphragm Unit RETROFIT AUTOMATIC DP CONTROLLER

V5012C Kombi-DP Diaphragm Unit RETROFIT AUTOMATIC DP CONTROLLER V5012C Kombi-DP Diaphragm Unit RETROFIT AUTOMATIC DP CONTROLLER Application PRODUCT DATA The V5012C Kombi-DP diaphragm unit is installed onto a V5010 Kombi-3-plus BLUE or V5032 Kombi-2-plus return mains

More information

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS Description VZ 2 VZ 3 VZ 4 VZ valves provie a high quality, cost effective solution for the control of hot an/or chille water for fan coil units, small reheaters, an recoolers in temperature control systems.

More information

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread

2 - way valve for steam, pressure relieved (PN 25) VGS - external thread Data sheet 2 - way valve for steam, pressure relieved (PN 25) VGS - external thread Description VGS is pressure relieved 2-way normally open (NO) valves for steam, designed to be combined with: - AVT Temperature

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS 0/05 OPERATING INSTRUCTIONS for gas pressure regulators PN0 with integrated slam shut valve (SSV) and integrated limited capacity safety relief valve (RV) MR 25 F0, MR 25 SF0 p e 20 kpa - 0 MPa (0,2-0

More information

Pressure independent control valve (PICV) FLOWMATIC

Pressure independent control valve (PICV) FLOWMATIC Pressure independent control valve (PICV) FLOWMATIC 145 series FM 21654 003 01262/19 GB replaces dp 01262/17 GB Function The pressure independent control valve is a device composed of an automatic flow

More information

STAD-C. Balancing valve ENGINEERING ADVANTAGE

STAD-C. Balancing valve ENGINEERING ADVANTAGE STA-C Balancing valve Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGINEERING AVANTAGE The STA-C balancing valve has been specially developed for use in indirect cooling systems

More information

3-port seat valves with externally threaded connection, PN 16

3-port seat valves with externally threaded connection, PN 16 4 463 Acvatix 3-port seat valves with externally threaded connection, PN 16 VXG41.. ronze CuSn5Zn5Pb2 valve body DN 15 50 k vs 1.6 40 m 3 /h Flat sealing connections with external thread G to ISO 228-1

More information

Pressure reducing valves Index

Pressure reducing valves Index Index General information page Introduction 506 General introduction 507 for a steam plant 509 Product information BSP thread page Brass 510 ; BSP female thread 511 ; BSP male thread 513 Stainless steel

More information

3-way control valves VK 3

3-way control valves VK 3 Data sheet 3-way control valves VK 3 Description / Application VK 3 valves are a range of 3 port high specification flanged valves for chilled water, LPHW, MPHW, HPHW (low, medium or high pressure hot

More information

Overview of types. Technical data. Safety notes

Overview of types. Technical data. Safety notes Technical data sheet R2..-S.. Open-close ball valves, 2-way, with internal thread For open and closed cold and warm water systems For shut-off functions on the water side and 2-point controls in U and

More information

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ]

Rp [ ] Sv min. [ ] C215QP-B 15 1/ C215QP-D 15 1/ C220QP-F 20 3/ [ ] Technical data sheet C2..QP-.. For closed cold and warm water systems For modulating control of airhandling and heating systems on the water side Snap-assembly of the actuator overview DN [ ] Vnom [ l/h]

More information

Pressure Reducing Valve DMV 750 set range: bar

Pressure Reducing Valve DMV 750 set range: bar Pressure Reducing Valve DMV 750 set range:.0-6.0 bar Advantage pressure setting possible at any time, also during operation hermetically sealed by valve diaphragm high level of operating safety and long

More information

USER MANUAL Version: 1/2017

USER MANUAL Version: 1/2017 ZETKAMA Sp. z o.o. ul. 3 Maja 12 PL 57-410 Ścinawka Średnia DIFREN PRESSURE REGULATING VALVE USER MANUAL Version: 1/2017 Fig. 223 Data: 01.01.2017 TABLE OF CONTENS 1. Product description 2. Requirements

More information

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE

Water valve Type WVO. Data sheet MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Data sheet Water valve Type WVO Water valve type WVO is used for regulating the flow of water in refrigeration plant with water-cooled condensers. The water valve gives modulating

More information

PVM 15-50, differential pressure valves

PVM 15-50, differential pressure valves PVM 15-5, differential pressure valves High accuracy Low pressure drop Quick to install Dimension: DN 15-5 Temperature: -1 C till +12 C Pressure class: PN 2(STV)/PN 25(PV) February 218 Rev. Description

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

Technical data sheet. Type overview. Technical data. Safety notes. T5-R2.. Open-close en v Subject to changes 1 / 3

Technical data sheet. Type overview. Technical data. Safety notes.   T5-R2.. Open-close en v Subject to changes 1 / 3 Technical data sheet R2.. Open-close ball valves, 2-way, with internal thread for open and closed cold and warm water systems for shut-off functions on the water side and 2-point controls in air-handling

More information

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS

The valves are used in combination with AMV(E) 130/140, AMV(E) 130H/140H and AMV(E) 13 SU actuators. DN k VS Description VZ 2 VZ 3 VZ 4 VZ valves provie a high quality, cost effective solution for the control of hot an/or chille water for fan coil units, small reheaters, an recoolers in temperature control systems.

More information