Reflux 819/FO. Pressure Regulators

Size: px
Start display at page:

Download "Reflux 819/FO. Pressure Regulators"

Transcription

1 ressure Regulators

2 ressure Regulators is a pilot-controlled pressure regulator for medium and high pressure applications. is normally a fail to open regulator that will open under the following conditions: - breakage of main diaphragm; - lack of pressure feeding to the pilot loop. The gas regulated by the Reflux should be clean, filtered, and non-corrosive.. Modular esign The is modular in design and allows retrofitting of a monitor M/819, slam shut valve and/or silencer in the same body. The regulator is truly a top entry design which allows for easy maintenance and retrofitting options in the field. The unique dynamic balancing control system ensures outstanding turn-down ratio combined with an extreme outlet pressure accuracy. ig. 1 ig. 2 + SIGN WIT YOUR NS IN MIN - ompact esign - Outstanding Turn own Ratio - asy Maintenance - igh ccuracy - Top ntry - Low Operation cost - Low Noise - xtreme lexibility

3 SILNR /819 With decibel noise limitations becoming an increasing safety concern, the silencer option is a unique feature that reduces regulator noise. When the silencer is installed, it allows for a considerable reduction in noise level (da) up to 30 da, depending upon the application. The pressure regulator can be supplied with an incorporated silencer in either the standard version or version with incorporated slam-shut or incorporated monitor regulator. With the built-in silencer, the g and KG valve coefficients are 5% lower than the corresponding version without the silencer. The silencer may be retrofitted to the standard as well as those with an incorporated slam-shut or monitor, without any need to modify the piping. ressure reduction and control operate in the same manner as the standard version. SLM SUT S/82 OR /97 ig. 3 ig. 4 The Reflux 819 O pressure regulator offers the possibility of installing an incorporated slam shut valve S/82 or /97 valve, depending on the regulator size. This can be done either during the manufacturing process or be retrofitted in the field. Retrofitting can be done without modifying the pressure regulator assembly. The g and KG coefficients of a regulator plus incorporated slam-shut system are 7% lower than those for standard versions. The main characteristics of this device are: - intervention for over pressure and/or under pressure - manual re-setting with internal bypass activated by the lever mechanism; - manual push button control; - compact dimensions; - easy maintenance; - optional pneumatic or electromagnetic remote control; - optional installation remote signal devices (contact switches or proximity switches).

4 MONITOR INORORT M/819 SLM SUT ig. 5 ig. 6 + M/819/O + M/819 This emergency regulator (monitor) is directly mounted onto the body of the main regulator. oth pressure regulators, therefore, use the same valve body, although they have indipendent actuators, pilots and valve seats. The operational characteristics of the M/819 monitor are the same as for the regulator The g and KG coefficients of a regulator having an incorporated monitor are 7% lower than those for the standard version. nother great advantage offered by the incorporated monitor regulator is that it can be installed at any time, even on an already existing regulator, without piping modification. This solution allows the construction of reduction lines with compact dimensions. The monitor regulator can either be a M/819/O fail to open regulator (fig. 5) or a M/819 fail to close regulator (fig. 6). MIN TURS > esign pressure: up to 1450 SIG (100 bar) > esign temperature: +14 to (-10 to + 60 ) (+ 4 to to + 60 on request) > mbient temperature: +14 to (-10 to + 60 ) ( + 4 to to + 60 on request) > Range of inlet pressure bpe: 43 to 1450 SIG (3 to 100 bar) > Range of outlet pressure Wh: 14,5 to 1073 SIG (1 to 74 bar) depending on installed pilot > Minimum working differential pressure: 30 SIG (2 bar) > ccuracy class : up to 1% > losing pressure class SG: from 5% to 1% depending on outlet pressure > vailable size N: > langing: class R or RTJ according to NSI 16.5 and N16 according to ISO 7005.

5 MTRILS ody ast steel STM 352 L for classes 300 and 600 STM 216 W for classes 150 and N16 ead covers STM 350 L2 orged steel Stem ISI 416 Stainless steel lug STM 350 L2 Nickel coated on sealing surfaces Valve seat Steel + vulcanized rubber Seals Nitrile rubber ompression fittings ccording to IN 2353 in zinc-plated carbon steel The characteristics listed above are referred to standard products. Special characteristics and materials for specific applications may be supplied upon request. g, KG and K1 coefficient Nominal diameter (mm) Size (inches) g flow coefficient K G flow coefficient K1 body shape factor ,220 2, ,937 5, ,000 8, ,607 17, ,933 27, ,525 38,425 or sizing formula refer to UTION: The graph gives a quick reference of maximum recommended regulator capacity depending on selected size. Values are expressed in actual S of Natural gas (s.g. 0.6): to have the data directly in S it is necessary to multiply the value by the outlet pressure value in psi absolute ctual flow rate ( ft3/h ) Logarithmic scale N 25 N 50 N 80 N 100 N 150 N 200 N 250 Outlet pressure ( psi) and more

6 ILOTS regulators are are equipped with with series series pilot pilot as listed as listed below: below: - 204/O. 204/. control control range range Wh: Wh: 0,314.5 to 43 to bar; 478 (4,5 SIG; to ( SIG) to 33 bar) - 205/O. 205/. control control range range Wh: Wh: to 60 to bar; 870 (290 SIG; to ( to SIG) 60 bar) - 207/O. 207/. control control range range Wh: Wh: to 74 to bar; 1073 (595 SIG; to 1073 (41 to SIG) 74 bar) ilots may be adjusted manually or remotely as shown in table 3: ilot Table: djustments ilot adjusting instructions ilot type.../ ilot type.../ ilot type.../s Manual setting lectric remote setting control Setting neumatic increased remote by setting pneumatic control signal remote point.i.o. Smart unit for remote setting, monitoring flow limitation and indirect flow measurement reregulators The pilot loop is completed with a device called preregulator, external to the pilot. The preregulators listed below are available: re-regulators - R14/: self adjusting preregulator that automatically regulates the feeding pressure to the pilot The pilot loop is completed with a device called pre-regulator, separate from the pilot. complete with integral filter at the inlet. The pre-regulators listed below are available: R34/: adiustable preregulator complete with integral filter at the inlet. - R14/O: self adjusting preregulator that automatically regulates the feeding pressure to the pilot complete with integral filter at the inlet. Table : ressostatic device Slam Shut Switch Selection evice MO. RSSOSTTI S VI MIN. MX 101M 0.14* * * 101M from 0,01 to 0,26 bar from 0,02 to 1 bar 102M M from , to 2,8 bar from 2.9 0, to 5,5 bar 103M 102M from 2.9 2, to 5,5 bar from 290, to 5,5 bar 103M M 103M from , to 8 bar from to bar 104M 103M from to bar from to bar 105M , M 104M from ,6-1, to 18 bar from ,5-1, to 45 bar 104M from 18 to 41 bar from 7,5 to 45 bar 105M from 3 to 44 bar from 30 to 90 bar MO. MIN. MX M from to 90 bar from to bar , / , , values in SIG

7 OTIONS Reflux 819 or Regulator - stroke limiter - flow-limiting devices - limit switches - position transmitters - steel fittings, single or dual sealing or ilot - supplementary filter 14 - dehydrating filter 14/ IN-LIN MONITOR The monitor is generally installed upstream of the main regulator. lthough the function of the monitor regulator is different, the two regulators are virtually identical from the point of view of their mechanical components. The only difference is that the monitor is set at a higher pressure than the main regulator. The g and KG coefficients of the regulator plus in-line monitor system are about 20% lower than those of the regulator alone. The in-line monitor can either be a fail to open regulator (fig.7) or a Reflux 819 fail to close regulator (fig.8). R14//O R14//O R14/ R14//O 204/ 204//O 204//O M/ 204//O ig. 7 ig. 8 M/ LRTOR When the monitor is required to take over rapidly in the event of a main regulator failure, an M/ accelerator pilot installation on the monitor is recommended. Installation of the accelerator is mandatory when the monitor is used as a safety accessory. This device, connected by sensing line to the downstream pressure, discharges the gas enclosed in the motorization chamber of the monitor regulator, allowing the monitor to take over faster. The set point of M/ accelerator is usually higher than the set point of the monitor by 0.66 to 1.10 SIG. In case of working monitor configuration (two stage pressure cut with monitor override), the accelerator may not be necessary.

8 RLUX 819/O G N N Overall dimensions in inches Inches 1" S - nsi 150/N 16 7, ,75 13,88 17,75 21,38 26,5 S - nsi 300 7,75 10,5 12,5 14,5 18,62 22,38 27,88 S - nsi 600 8,25 11,25 13,25 15, , G Tubing onnections 1/4 NT S ace to face dimensions S according to I and NSI Weights in Lbs S - nsi 150/N ,984.1 S - nsi , ,094.3 S - nsi , ,204.6 RLUX 819/O + S82 / + 97 G N N Overall dimensions in inches * /97 Inches 1" S - nsi 150/N 16 7, ,75 13,88 17,75 21,38 26,5 S - nsi 300 7,75 10,5 12,5 14,5 18,62 22,38 27,88 S - nsi 600 8,25 11,25 13,25 15, , * * * * * * * * * * * * G Tubing onnections 1/4 NT S * /97 *Indicates dimensions with the MOL /97 ace to face dimensions S according to I and NSI Weights in Lbs S - nsi 150/N * * 1, ,12.7* 2, ,970.9* S - nsi * * 1, ,320.5* 2, ,403* S - nsi * ,049.4* 1, ,507.9* 2, ,645.5*

9 RLUX 819/O + M819 G N N L S Overall dimensions in inches Inches S - nsi 150/N 16 S - nsi 300 S - nsi 600 G L Tubing onnections * M819/O 1" * 18.14* 29.21* 17.12* 20.27* 34.25* 19.29* 23.22* 38.58* * 25.27* 41.88* * 34.4* 62.12* * 38.85* 69.84* /4 NT ace to face dimensions S according to I and NSI Weights in Lbs S - nsi 150/N 16 S - nsi 300 S - nsi , , , ,477 1, , , , , * 46.25* 84.64* 30.51*

10 RLUX 819/O + /819 G Overall dimensions in inches S Inches 1" S - nsi 150/N S - nsi S - nsi G K Tubing onnections 1/4 NT N N K ace to face dimensions S according to I and NSI Weights in Lbs S - nsi 150/N , , ,821.9 S - nsi , , ,042.3 S - nsi , , ,152.6 RLUX 819/O+/819+S82 /+97 G N N Overall dimensions in inches K Inches 1" S - nsi 150/N S - nsi S - nsi * * * * * * * * * * * * G K Tubing onnections 1/4 NT */97 S * /97 *Indicates dimensions with the MOL /97 ace to face dimensions S according to I and NSI Weights in Lbs S - nsi 150/N * 1,272 1,254.4* 1, ,254.4* 2, ,254.4* S - nsi * 1, ,514.5* 2, ,514.5* 3, ,514.5* S - nsi * 1,455 1,666.6* 3, ,666.6* 3, ,666.6*

11 RLUX 819/O + /851 + M/819 G N N L S Overall dimensions in inches 1" Inches 7.25 S - nsi 150/N S - nsi S - nsi * * G * * L 8.66 K Tubing onnections * 20.27* 43.11* 11.22* K K * M819/O * 23.22* 49.21* * * * * * /4 NT 31.06* 34.4* 73.34* 18.07* * 38.85* 83.03* 19.96* * * * * ace to face dimensions S according to I and NSI Weights in Lbs S - nsi 150/N 16 S - nsi 300 S - nsi , , , , , , , ,254.9

12 ietro iorentini Solutions Reducing and Metering Stations Slam Shut Valves all Valves SISTMR!!!!!!!! iorentini US 4555 South erkeley Lake Road Norcross, G Toll - ree: ax: ietro iorentini S.p.. via.ermi 8/10 I rcugnano (VI) Italy Tel: ax: This data is not binding. We reserve the right to make changes without prior notice. T-s 504-US November 12

Aperval Pressure Regulators

Aperval Pressure Regulators Pressure Regulators Pressure regulators is pilot-controlled pressure regulator for medium and low pressure applications. is normally a fail to open regulator and specificaly will open under the following

More information

Pressure Regulators. Aperflux 851

Pressure Regulators. Aperflux 851 Pressure Regulators Aperflux 851 80 1 2 3 4 5 6 7 Aperflux 851 > Pressure regulators Introduction Aperflux 851 is a boot style pilot-controlled pressure regulator for medium and high pressure applications.

More information

Pressure Regulators. Reval 182 ANSI 300

Pressure Regulators. Reval 182 ANSI 300 ressure Regulators Reval 182 NI 300 Reval 182 NI 300 > ressure regulators Introduction Reval 182 is a pilot-controlled pressure regulator for medium and low pressure applications. Reval 182 is normally

More information

Pressure Regulators. Aperflux 101

Pressure Regulators. Aperflux 101 Pressure Regulators Aperflux 101 Aperflux 101 > Pressure regulators Top Easy Maintenance Integral Silencing Cage High Accuracy Dinamically Balanced Pilot Installation On Any Position Introduction Aperflux

More information

Norval Pressure Regulators

Norval Pressure Regulators Pressure Regulators Pressure regulators NORVAL pressure regulators are balanced direct acting devices for low and medium pressure applications controlled by a diaphragm and counter spring. These regulators

More information

ASX 176 Axial Pressure regulator

ASX 176 Axial Pressure regulator ASX 176 Axial Pressure regulator ASX 176 Classification and Area of Application ASX 176 is a downstream pressure regulator, pilot controlled, for medium and high pressure applications. It is particularly

More information

Dival 600. Pressure Regulators

Dival 600. Pressure Regulators Dival 600 Pressure Regulators Pressure regulators Dival 600 Dival 600 series pressure regulators are direct acting devices for low and medium pressure applications controlled by a diaphragm and counter

More information

Pressure regulators. Introduction. TR Head. 3 ways body Dival

Pressure regulators. Introduction. TR Head. 3 ways body Dival Pressure Regulators > Pressure regulators Introduction series pressure regulators are direct acting devices for low and medium pressure applications controlled by a diaphragm and counter spring. These

More information

Norval Pressure regulator

Norval Pressure regulator Norval Pressure regulator NORVAL Classification and Field of Application The NORVAL is a downstream pressure regulator, self actuated, spring loaded for medium and low pressure applications. It is suitable

More information

Slam Shut Valves SBC 782

Slam Shut Valves SBC 782 Slam Shut Valves SBC 782 SBC 782 > Slam shut valves Introduction SBC 782 is a compact safety device (SAV) which quickly intercepts gas flow whenever the pressure under monitoring reaches preset limits,

More information

Slam Shut Valves SCN

Slam Shut Valves SCN Slam Shut Valves SCN SCN > Slam shut valves Introduction SCN is a compact safety device (SAV) which quickly intercept gas flow whenever the pressure under monitoring reaches a pre-set limits, or whenever

More information

RB 4700 Commercial & Industrial Regulator

RB 4700 Commercial & Industrial Regulator RB 4700 Commercial & Industrial Regulator The RB 4700 regulator is designed for use in industrial and distribution applications such as district station and heating plants, and for industrial customers.

More information

Dival 500 Pressure Regulators

Dival 500 Pressure Regulators Dival 500 Pressure Regulators Dival 500 Classification and Range of use The DIVAL 500 is a downstream direct-acting pressure regulator with balanced plug, for low, medium and high pressures. Suitable for

More information

RTG 25. Introduction

RTG 25. Introduction Introduction RTG 25 pressure regulator is included within the direct acting and balanced valve regulator class. These regulators have a large range of applications both in industrial and domestic installations.

More information

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator

Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator January 2009 Type 310A-32A Pressure Reducing Regulator and Type 310A-32A-32A Working Monitor Regulator Introduction The Type 310A pilot-operated high-pressure regulator (Figure 1) is used where high capacity

More information

Type Cronos Pressure Reducing Regulator

Type Cronos Pressure Reducing Regulator Type Cronos Pressure Reducing Regulator March 2002 E0838 Figure 1. Type Cronos Regulator Features! Control ccuracy Keeps constant inlet pressures to downstream equipment by accurately controlling system

More information

GAS PRESSURE REGULATORS AP

GAS PRESSURE REGULATORS AP A Long Experience in Energy Equipment and one Goal: The Customer s satisfaction. GAS PRESSURE REGULATORS AP (High Pressure) ALPHARD P/AP Pressure Regulator Applications It is designed for use in transmission

More information

RB 4700 Commercial & Industrial Regulator

RB 4700 Commercial & Industrial Regulator RB 4700 Commercial & Inustrial Regulator The RB 4700 regulator is esigne for use in inustrial an istribution applications such as istrict station an heating plants, an for inustrial customers. DESCRIPTION

More information

Deltaflux Control Valve

Deltaflux Control Valve Control Valve Valvola di regolazione control valve is an ideal solution for all fluid control applications where high differential pressure or great flow rates are involved. The refined design of the rotating

More information

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators

IP2, IP2A and IP2D. Spirax-Monnier International Compressed Air Filter/ Regulators Page 1 of 6 TI-P510-01 H Issue 5 IP2, IP2 and IP2D ISO 9001 Spirax-Monnier International ompressed ir Filter/ Regulators ert. No. LRQ 0963008 Description The IP range of Spirax-Monnier international compressed

More information

RR 16 Commercial & Industrial Regulator

RR 16 Commercial & Industrial Regulator RR 16 Commercial & Industrial Regulator The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations where accurate

More information

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071

COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES. Lamar Jones. Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071 COMPARING PLUG & SEAT REGULATORS & CONTROL VALVES Lamar Jones Equipment Controls Company 4555 South Berkeley Lake Road Norcross, GA 30071 INTRODUCTION The purpose of this paper will be to compare a plug

More information

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class.

RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class. Introduction RTG 311 pressure regulators are included within the direct acting and balanced valve regulator class. The regulator is used for reducing and regulating the pressure of natural gases and LPG,

More information

Type 299 Pressure Reducing Regulators

Type 299 Pressure Reducing Regulators Type 299 Pressure Reducing Regulators Fisher, Fisher-Rosemount, and Managing The Process Better are marks owned by Fisher Controls International, Inc. or Fisher-Rosemount Systems, Inc. All other marks

More information

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES

MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES MWEA MAINTENANCE SEMINAR SPECIALTY VALVES POWER GLOBES J O H N G. H U N T E R Types of Valves P A U L M A R C H I Accessories Principals of Operation Maintenance Control Valve Types Common Problems Key

More information

Safety Shut-off Valve SSV

Safety Shut-off Valve SSV Safety Shut-off Valve SSV 8200-8300 < Accurate operation < Compact design < Easy maintenance Applications The safety shut-off valve is designed for use in gas distribution, and pressure regulation systems.

More information

RB 4000 Commercial & Industrial Regulator

RB 4000 Commercial & Industrial Regulator R 4000 ommercial & Industrial Regulator The R 4000 pressure regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants and all installations where accurate

More information

RR 16 Commercial & Industrial Regulator

RR 16 Commercial & Industrial Regulator Gas RR 16 Commercial & Industrial Regulator Applications The RR 16 regulator is designed for industrial use: gas supply networks, district stations, industries, heating plants, as well as for all installations

More information

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls

Type 1098-EGR. Pilot-Operated Valve Link Regulators. Features. Fisher Controls Type 1098-EGR and Type 1098H-EGR VL1000 FIELDVUE Pilot-Operated Valve Link Regulators Fisher Controls January 1982 Bulletin The Type 1098-EGR and Type 1098H-EGR regulators (figure 1) provide economical

More information

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators

IP2M, IP2AM and IP2DM Monnier International Compressed Air Filter/ Regulators L ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification

More information

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

CSB400 Series Commercial / Industrial Pressure Reducing Regulators CSB400 Series Commercial / Industrial Pressure Reducing Regulators Bulletin 71.1:CSB400 April 2011 CSB400 SERIES PRESSURE REDUCING TYPICAL CSB403 WITH INTEGRAL TRUE-MONITOR TYPICAL CSB404 WITH INTEGRAL

More information

GE Oil & Gas. Mooney * Flowgrid * Slam Shut Regulator. Delivering accuracy, performance and protection

GE Oil & Gas. Mooney * Flowgrid * Slam Shut Regulator. Delivering accuracy, performance and protection GE Oil & Gas Mooney * Flowgrid * Slam Shut Regulator Delivering accuracy, performance and protection Industries Gas transmission Gas distribution Midstream gas Gas processing Applications Gas pipelines

More information

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators

61 Series Pilots for Pilot-Operated Pressure Reducing Regulators 61 Series Pilots for Pilot-Operated Pressure Reducing Regulators June 2011 Introduction 61 Series pilots are used with Types 1098-EGR and EZL pressure reducing regulators. These pilots can also be integrally

More information

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY

TECHNICAL DATA 3 MODEL G-3000 DRY VALVE RISER ASSEMBLY Page 1 of 13 1. DESCRIPTION The Viking 3 Model G-3000 Dry Valve Riser Assembly is equipped with a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG

1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG A C E D SB-8520.2 1800CPB2 Service Regulators Maximum Inlet 125 PSIG AMC Quality System QMI is Accredited by: C R E D I T ISO 9001 Certified Certificate #006697 R E ANSI RAB G I S T R A R Dutch Council

More information

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX

3/2-way valve, Series CD07 Qn= 1400 l/min pipe connection compressed air connection output: G 1/4 - M14x1,5 suitable for ATEX /-way valve, Series CD07 Version Spool valve, zero overlap Sealing principle soft sealing Working pressure min./max. -0.95 bar / 0 bar Ambient temperature min./max. -5 C / +80 C Medium temperature min./max.

More information

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS

Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS Paul Ladage 26 September 2017 MOVING THINGS AROUND - LATEST TRENDS IN HONEYWELL FLAGSHIP REGULATORS Agenda 1 What do we sell? Flagship Products HON 5020 HON R100 NG HON 512, class 150 Q&A Where Do Honeywell

More information

Type EZH Relief or Backpressure Regulator

Type EZH Relief or Backpressure Regulator Bulletin 71.4 D103574X012 Type EZH December 2017 Type EZH Relief or Backpressure Regulator P1668 Figure 1. Type EZH Relief Valve or Backpressure Regulator Features Bubble Tight Shutoff A knife-edged metal

More information

Gas Pressure Regulator HON 300

Gas Pressure Regulator HON 300 Product information serving the gas industry worldwide Applications, characteristics, technical data Applications direct acting gas pressure regulator, for systems in accordance with DVGW working instruction

More information

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13

TECHNICAL DATA Q = C. v P S. 2 Model G-2000 Dry valve. Page 1 of 13 Page 1 of 13 1. Description The Viking 2 Model G-2000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features

BERMAD Waterworks. Level Control Valve with Altitude Pilot. 700 Series. Model X. Features and Benefits. Major Additional Features Level Control Valve with Altitude Pilot High level reservoirs & water towers Energy cost critical systems Systems with poor water quality Inherent refreshing Level sustaining at reservoir outlet The Level

More information

Industrial Regulator Series 1800/2000

Industrial Regulator Series 1800/2000 E S 85. Industrial Regulator Series / M Quality System QMI is ccredited by: R E I T ISO 9 ertified R E NSI R G I S T R R utch ouncil for ccreditation Measurement Engineers Since 86 merican Meter Series

More information

1800CPB2 Service Regulators

1800CPB2 Service Regulators SB 8520.5 1800CPB2 Service Regulators Maximum Inlet Pressure 125 PSIG Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................ 4-6 1-1/4" Models,

More information

PRESSURE REDUCING VALVE RP45 (EN)

PRESSURE REDUCING VALVE RP45 (EN) PRESSURE REDUCING VALVE RP45 (EN) DESCRIPTION The ADCA RP45 series pressure reducing valves are single seat bellows sealed controllers, operating without auxiliary energy, designed for use on steam, compressed

More information

CSB400 Series Commercial / Industrial Pressure Reducing Regulators

CSB400 Series Commercial / Industrial Pressure Reducing Regulators October 2015 CSB400 Series Commercial / Industrial Pressure Reducing Regulators P1424 TYPE CSB400 PRESSURE REDUCING P1426 TYPICAL TYPE CSB403 WITH INTEGRAL TRUE-MONITOR P1425 TYPICAL TYPE CSB404 WITH INTEGRAL

More information

Model 1800 PFM Series Regulator. Technical Bulletin

Model 1800 PFM Series Regulator. Technical Bulletin Model 0 PFM Series Regulator Technical Bulletin Model 0 PFM Series Regulator 0 Elster American Meter The 0 PFM Series regulators are designed to control natural gas, air, nitrogen, carbon dioxide, propane

More information

Gas pressure regulator RSP 254 / RSP 255. Product information. Regulator R / R / R Actuator AS 254 / AS 255

Gas pressure regulator RSP 254 / RSP 255. Product information. Regulator R / R / R Actuator AS 254 / AS 255 Gas pressure regulator RSP 254 / RSP 255 Regulator R 70-10 / R 70-20 / R 70-100 Actuator AS 254 / AS 255 Product information Subject to modifications! Reprint prohibited! Table of Contents Application,

More information

Series 100 Slam Shut Valve. Technical Bulletin

Series 100 Slam Shut Valve. Technical Bulletin Series 100 Slam Shut Valve Technical Bulletin 02 Elster The Series 100 Slam Shut protects gas installations against overpressure conditions by automatically shutting off the gas flow. General Information

More information

VERTICAL BLADDER TANK

VERTICAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Tight Spaces UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

829S1 Series Flexflo Pilot

829S1 Series Flexflo Pilot REDQ Regulators The Model 829S1 Provides Versatile Pressure Regulation At An Economical Price. The Model 829S1 Flexflo Pilot is a reversible pressure control regulator (seat & nozzle) that is used in conjunction

More information

299H Series Pressure Reducing Regulators

299H Series Pressure Reducing Regulators September 12 299H Series Pressure Reducing Regulators Inlet Pressure up to psig / 1 bar Compact ±1% Accuracy for Fixed Factor Billing (PFM) Rugged Construction Integral Pilot Easy to Maintain W713 Figure

More information

P33 Safety Exhaust Valve Externally Monitored. Bulletin 0700-B14 ENGINEERING YOUR SUCCESS.

P33 Safety Exhaust Valve Externally Monitored. Bulletin 0700-B14 ENGINEERING YOUR SUCCESS. P Externally Monitored ulletin 07004 ENGINEERING YOUR SUESS. Features Externally Monitored Function When applications demand a safe environment you can count on safety valves from Parker Hannifin. The

More information

TECHNICAL DATA. Q= Cv S

TECHNICAL DATA. Q= Cv S Page 1 of 13 1. DESCRIPTION The Viking 4 inch Model G-4000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry

More information

DNS. Monoblock directional control valves DNS - Directional control valve

DNS. Monoblock directional control valves DNS - Directional control valve Monoblock directional control valves DNS - Directional control valve DNS efore use, carefully read the GENERL INSRUCIONS FOR USE OF DIRECIONL CONROL VLVES 398SMD6I - 6--8 DNS echnical data Nominal flow

More information

HON C210 Series Control Valves. High Pressure Control valves

HON C210 Series Control Valves. High Pressure Control valves HON C210 Series Control Valves High Pressure Control valves technical specifications General Type indication HON C210 series Pressure class ANSI 300 and ANSI 600(*) Inlet pressure range 0 to 50 bar ANSI

More information

Pressure and Flow Control Valves DBGM, German and European Patents

Pressure and Flow Control Valves DBGM, German and European Patents Pressure and Flow Control Valves DBGM, German and European Patents Absolutely Reliable Pressure and Flow Control In water mains of sizes DN 50 to DN 150, ERHARD Control Valves in straight or angle pattern

More information

HORIZONTAL BLADDER TANK

HORIZONTAL BLADDER TANK Balanced Pressure Proportioning System Reliable Foam System Requiring Only Water Power Perfect For Low Ceilings UL Listed, ASME, National Board Registered Bladder-UL162 Approved, High Tensile Pressure

More information

TECHNICAL DATA. Q = C v P S

TECHNICAL DATA. Q = C v P S Page 1 of 13 1. DESCRIPTION The Viking 6 Model G-6000 Dry Valve Riser Assembly consists of a small profile, light weight, pilot operated valve that is used to separate the water supply from the dry sprinkler

More information

Safety Cut-Off Valve HON 305

Safety Cut-Off Valve HON 305 Safety CutOff Valve HON 305 PRODUCT INFORMATION Serving the Gas Industry Worldwide SAFETY CUTOFF VALVE HON 305 Introduction, Application, Features, Technical Data Introduction The HON 305 is a safety cutoff

More information

Leak free Pipe Rupture Valve for Excavators

Leak free Pipe Rupture Valve for Excavators Leak free Pipe Rupture Valve for xcavators Series motion and progress Reference: 3 P 9575 1/11.6 Classification: 43.325.355...325.35 1/17 Contents Page 1 General description................................................................

More information

Gas Pressure Regulator HON 502

Gas Pressure Regulator HON 502 Gas Pressure Regulator HON 502 Product information serving the gas industry worldwide Gas Pressure regulator HON 502 Application, Characteristics, Technical Data Application for offtake stations in gas

More information

Type R622 Pressure Reducing Regulator

Type R622 Pressure Reducing Regulator Type R622 Pressure Reducing Regulator June 2010 Compact Design Protective Inlet Screen High Capacity Internal Relief Light Weight W8806 Inlet and Outlet Pressure Gauge Taps Figure 1. Type R622 Pressure

More information

971 Series Pressure Reducing Regulators

971 Series Pressure Reducing Regulators 971 Series Pressure Reducing Regulators September 2011 E0833 Figure 1. 971 Series Regulators Features Control ccuracy Keeps constant inlet pressures to downstream equipment by accurately controlling system

More information

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators July 2010 W3716 W3507 Type 1808 Type 1808A Figure 1. Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

More information

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified

Cash Valve TYPE KP PILOT OPERATED BACK PRESSURE VALVE. ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 9001 Certified Cash Valve PILOT OPERATED BACK PRESSURE VALVE ISSUED - DECEMBER 2000 CAVMC-0518-US-0208 ISO 01 Certified KP HIGH CAPACITY PILOT OPERATED BACK PRESSURE VALVE DESCRIPTION The Cash Valve Type KP is a pilot

More information

TECHNICAL DATA. than the water inlet pressure to the concentrate

TECHNICAL DATA. than the water inlet pressure to the concentrate Foam102a 1. DESCRIPTION The Viking Low Flow Foam/Water proportioning system, is a UL Listed and FM Approved system, for use with 3M foam concentrates. This system consists of a standard wet pipe sprinkler

More information

CALEFFI. Ball zone valves. series /03 GB

CALEFFI. Ball zone valves. series /03 GB all zone valves series cert. n ISO / Function Zone valves are used to automatically shut-off the flow of carrier fluid distributed to a system. Specifically: -In central heating systems, they support the

More information

North American 7339 High Pressure Gas Regulators

North American 7339 High Pressure Gas Regulators Combustion North American 7339 High Pressure Gas Regulators Bulletin 7339 7339 Regulators reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across

More information

PRESSURE REGULATORS. Type A/140. Process Management TM

PRESSURE REGULATORS. Type A/140. Process Management TM PRESSURE REGULATORS Type A/140 Process Management TM A/140 Series Pressure Regulator The regulators of the A/140 series due to their operating specifications are mainly used in those system where sudden

More information

1800CPB2 Pilot-Loaded Service Regulators

1800CPB2 Pilot-Loaded Service Regulators 1800CPB2 Pilot-Loaded Service Regulators Technical Bulletin www.elster-americanmeter.com Table of Contents 1800CPB2 Regulator Information................ 2-3 1800CPB2 Capacity Performance................

More information

PRO-50 Instrument Supply Regulator

PRO-50 Instrument Supply Regulator Features CRN Approved The PRO-50 Regulator has been granted a Canadian Registration Number. Sour Service Capability Available in NACE configurations that comply with NACE MR0175/MR0103. Environmental limits

More information

HON HSV086 Series Safety Shut-off Valves for Efficient, Sustainable and Safe Gas Distribution. Proven Technology. Superior Performance.

HON HSV086 Series Safety Shut-off Valves for Efficient, Sustainable and Safe Gas Distribution. Proven Technology. Superior Performance. HON HSV086 Series Safety Shut-off Valves for Efficient, Sustainable and Safe Gas Distribution Proven Technology. Superior Performance. HON HSV086 and HON HSVS086 Series Valves Designed to offer overpressure

More information

Actuator HON 670 / 671

Actuator HON 670 / 671 Actuator HON 670 / 67 Product information serving the gas industry worldwide Applications, characteristics, technical data Application The actuators HON 670 (K6, K8) and HON 67 (K7) are used to trigger

More information

FILTER BYPASS CONTROL

FILTER BYPASS CONTROL Differential Control Valve Series 110 The Series 110 Differential Control Valve is designed to accurately control the pressure difference between any two points. In some systems this means the valve remains

More information

Bermad Pressure Reducing. Model: 42T

Bermad Pressure Reducing. Model: 42T Bermad Pressure Reducing Pilot Operated Pressure Control Valve Model: 42T Installation Operation Maintenance Manual (IOM) REV. 27.7.17 Page 1 of 12 Safety First BERMAD believes that the safety of personnel

More information

PRESSURE REGULATORS. Type B/240. Process Management TM

PRESSURE REGULATORS. Type B/240. Process Management TM PRESSURE REGULATORS Type B/240 Process Management TM B/240 Series Pressure Regulator The regulators of the B/240 series due to their operating specifications are mainly used in those system where sudden

More information

SLAM-SHUT VALVES. Type BM5. Process Management TM

SLAM-SHUT VALVES. Type BM5. Process Management TM SLAM-SHUT VALVES Type BM5 Process Management TM BM5 Slam-Shut Valves Slam-shut valves BM5 series slam-shut valve is an automatic shut-off appliance suitable for installation as safety device in regulating

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 1, 01 VGG VGD0 VGD0 Description Only when assembled to Series SKP actuators

More information

1805 Series Relief Valves

1805 Series Relief Valves Instruction Manual Form 1211 1805 Series October 2011 1805 Series Relief Valves! WARNING Failure to follow these instructions or to properly install and maintain this equipment could result in an explosion

More information

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000

Pressure and/or Temperature Pilot Operated Steam Regulators Series 2000 Hoffman Specialty Regulators Regulators Pressure and/or Temperature Operated Regulators Series 2000 The Hoffman Specialty Series 2000 consists of main valves, pilot valves, wells and hardware kits. They

More information

Bulletin 71.6:OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction

Bulletin 71.6:OSE. Type OSE Slam-Shut Valve. Features and Benefits. Introduction March 2010 Type OSE Slam-Shut Valve W8131 Figure 1. Type OSE Slam-Shut Valve Features and Benefits Overpressure and Underpressure Protection Type OSE can be equipped for OverPressure ShutOff (OPSO), UnderPressure

More information

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION

SPECIFICATIONS. Approximate Weight: 10 oz. Surface Finish: Ra micro inch or less MATERIALS OF CONSTRUCTION DIFFUSION-RESISTANT, DIAPHRAGM SEAL, EXCESS FLOW SHUT-OFF VALVES (FS SERIES) FS Series Excess Flow Shut-Off Valves are designed to automatically shut-off the delivery of gas in a line if the flow exceeds

More information

E28/Q28 Safety Exhaust Valve Externally Monitored

E28/Q28 Safety Exhaust Valve Externally Monitored E8/Q8 Safety Exhaust Valve Externally Monitored ulletin 9EM4 the total systems approach to air preparation Features Externally Monitored Safety Exhaust Valve Function When applications demand a safe environment

More information

Pressure ranges and accuracy classes for outlet pressure and safety devices

Pressure ranges and accuracy classes for outlet pressure and safety devices M2R Two Stage Regulator Applications Pressure reduction for: - Domestic use - Small industrial applications Brief information The two stage pressure regulator M2R is available in various capacity stages,

More information

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series

Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure. DMV-D/624L Series DMV-DLE/624L Series Dual Safety Shutoff Valves with Proof of Closure and NEMA 4x Enclosure DMV-D/624L Series DMV-DLE/624L Series Two normally closed automatic shutoff valves in one housing. Valve 2 (V2) incorporates proof

More information

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features

BERMAD Waterworks. Pressure Reducing Valve. 700 Series. Model 720. Features and Benefits. Major Additional Features Pressure Reducing Valve Flow and leakage reduction Cavitation damage protection Throttling noise reduction Burst protection System maintenance savings The Pressure Reducing Valve is a hydraulically operated,

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

RELIEF VALVES. Type VS- FL. Process Management TM

RELIEF VALVES. Type VS- FL. Process Management TM RELIEF VLVES Type VS- FL Process Management TM Relief Valves This series of axial flow relief valves was designed to meet a wide range of applications. Large appreciation from worldwide customers is a

More information

Pilot HON 630a, HON 640

Pilot HON 630a, HON 640 product information serving the gas industry worldwide pplication, characteristics, technical data pplication pilot for gas pressure regulators HON 0, HON 0, HON 0, HON 0 suitable for natural gas and all

More information

Pressure independent control valve (PICV) FLOWMATIC

Pressure independent control valve (PICV) FLOWMATIC Pressure independent control valve (PICV) FLOWMATIC 145 series FM 21654 003 01262/19 GB replaces dp 01262/17 GB Function The pressure independent control valve is a device composed of an automatic flow

More information

Noth American 7347 High Pressure Gas Regulators

Noth American 7347 High Pressure Gas Regulators Combustion Noth American 7347 High Pressure Gas s Bulletin 7347 7347 s reduce high gas supply pressures to practical use levels. Since capacities will vary with the pressure drop across the regulator (see

More information

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634

Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Dual Modular Safety Shutoff Valves with Proof of Closure and NEMA Type 4x Enclosure DMV-D 704/624 DMV-D 704/634 DMV-DLE 704/624 DMV-DLE 704/634 Two normally closed automatic shutoff valves in one housing.

More information

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations

RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations RMG 5020 Gas Pressure Regulator Enabling Dependable Gas Operations Proven Technology. Superior Performance. Today s natural gas industry has a growing demand for operational excellence. Pilot-operated

More information

Type 63EG Relief Valve or Backpressure Regulator

Type 63EG Relief Valve or Backpressure Regulator July 11 Type 63EG Relief Valve or Backpressure Regulator W6955 NACE Construction Backpressure Regulator Relief Valve Oxygen Service Natural Gas Liquids Figure 1. Type 63EG Fast Pilot Reseat Low Buildup

More information

Self-operated Regulators Accessories Differential Pressure and Flow Regulators

Self-operated Regulators Accessories Differential Pressure and Flow Regulators Self-operated Regulators Accessories Differential Pressure and Flow Regulators Compression-type fittings Needle valves Compensation chambers Orifice plates Welding neck flanges Control lines Application

More information

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25

Mounting and Operating Instructions EB 3007 EN. Self-operated Pressure Regulators. Differential Pressure Regulators (opening) Type Type 42-25 Self-operated Pressure Regulators Differential Pressure Regulators (opening) Type 42-20 Type 42-25 Type 42-20 Differential Pressure Regulator Type 42-25 Differential Pressure Regulator Mounting and Operating

More information

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work?

94270 Vapor Guard Tank Blanketing Valve Vapor Guard Tank Blanketing Valve What is Tank Blanketing? Features How does it work? 94270 What is Tank Blanketing? blanketing systems are used to prevent the escape of liquid vapors into the atmosphere or to prevent moisture from entering a tank and contaminating its contents. A tank

More information

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators

VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators VG Series VGG and VGD Gas Valves for use with SKP Electro-hydraulic Actuators Technical Instructions Document No. 155-51P5 VG August 11, 005 GAS009R1 VGG VGD0 VGD0 Description Only when assembled to SKP

More information

Gas Pressure Regulator HON 200

Gas Pressure Regulator HON 200 Product information serving the gas industry worldwide Applications, characteristics, technical data Application Gas supply to municipal, industrial and individual consumers Regulator for low-load rails

More information

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2

Regulator: Modular Type with Back flow Mechanism. AR30K to 60K. Body size. Port size 1/4 3/8 1/2 3/4 AR40 AR50 3/4 1/2 Regulator: Modular Type with ack flow Mechanism R3 to 6 How to Order Regulator with a built-in mechanism that ensures a quick release of the outlet air pressure (built-in check valve with back flow mechanism).

More information