Standard Operating Procedures (SOP) for Desert Locust Ground Control. 2 Desert Locust Ground Control SOP. 1. Control process.

Size: px
Start display at page:

Download "Standard Operating Procedures (SOP) for Desert Locust Ground Control. 2 Desert Locust Ground Control SOP. 1. Control process."

Transcription

1

2 Standard Operating Procedures (SOP) for Desert Locust Ground Control Objective The objective of the Standard Operating Procedures (SOP) for Desert Locust Control is to give concise instructions for good insecticide application against the Desert Locust. These instructions are intended for use by the field staff who are involved in Desert Locust operations (including Locust Officers and technicians) in order to help them to avoid dangerous, ineffective or wasteful control operations. They are based on the FAO Desert Locust Guidelines where more detailed information and references are available. The instructions focus on: ULV insecticide spraying ULV spray equipment 1. Control process A series of steps needs to be followed before, during and after control operations. PREPARATIONS three months before control operations Select competent control teams and provide them with training or refresher training Check and service the vehicles Check and test all spray equipment and check that commonly needed spare parts are available Distribute the required quantity and type of insecticides to the likely spray sites Make sure that operational funds are allocated for the proposed control period to cover field allowances, fuel, etc. Make sure that aircraft are available in the country and can be contracted by the MoA for control operations. Check that airstrips have been maintained Ensure that enough copies of the FAO Spray Monitoring Form are available Techniques for safe and efficient operations 1 Desert Locust Ground Control SOP 2 Desert Locust Ground Control SOP

3 BEFORE control operations Step 1. Choose appropriate control method (equipment, insecticide and technique), which depends on infestation size, urgency of action and work rate required. Step 2. Calibrate your spray equipment in order to assure the correct amount of insecticide is applied in the right way and in the right place. Step 3. Ensure that local inhabitants are informed about the date, time and location of control operations, so that they can move their livestock, beehives and families to safety. Step 4. Find the wind direction in order to establish a spray direction at right angles to it and demarcate the infested area. Step 5. Make sure that temperature, wind and rainfall conditions are suitable for the control operation. DURING control operations Step 6. Make sure that: All staff who are handling or applying insecticide use full protective clothing All spraying equipment and personnel are at the downwind edge of the area to start spraying (from downwind towards upwind) All other non-spraying personnel, vehicles and equipment are at the upwind edge of the target area to avoid contamination by the sprayed insecticide Start spraying cross-wind (at right angles to the wind direction), moving upwind after each spray pass, making sure to measure the correct track spacing using flagmen or other means Make an extra spray pass upwind of the target area to prevent under-dosing at the upwind edge Stop spraying if the wind drops (less than 1 m/s) or becomes very strong (more than 10 m/s) and wait for the right conditions Stop spraying if it starts to rain or seems likely to rain soon Stop spraying if the wind direction changes by more than 45 degrees, adjust your new spray line and spray the remaining area 3 Desert Locust Ground Control SOP 4 Desert Locust Ground Control SOP

4 AFTER control operations Step 7. Monitor and record all relevant details on the FAO Spray Monitoring Form. Step 8. Empty any insecticide remaining in the sprayer back into the original insecticide container. Clean and maintain equipment, and store the sprayers, the insecticide and the empty containers in safe places. Step 9. Wash yourself and the protective clothing as soon as possible. 2. Control team and field equipment Control Team: two locust officers, two drivers and two vehicles, plus support staff such as assistants and skilled labourers. Equipment: to be available in each vehicle: Hand-held GPS (1) Maps Compass FAO forms (2) Clipboard, paper and pen Anemometer Hygrometer Oil sensitive paper to sample ULV droplets Bucket and plastic measuring cylinder or jug Vibrating tachometer Stop watch Hand lens (x10) Sweep net Tool kit First aid kit HF radio Cages for mortality assessment Water and soap for washing Sets of protective clothing for all staff handling insecticides (1) extra batteries, cigarette lighter adapter, remote antenna (2) Survey & Control Forms and Spray Monitoring Forms 5 Desert Locust Ground Control SOP 6 Desert Locust Ground Control SOP

5 3. Principles of ULV application Ultra low volume (ULV) spraying uses small amounts of concentrated insecticide. In locust control, about litre/hectare is applied. The insecticide is not mixed with water or solvent. It is oil-based to prevent evaporation and is usually applied ready to spray. Droplets of spray are carried by the wind. In full coverage treatments, the insecticide is sprayed as overlapping swaths onto the control target so that a uniform deposit is achieved and the locusts receive enough insecticide. Remember: Do not spray during the hottest part of the day ( hr) when convection may occur and carry the spray up into the sky instead of down onto the locusts Do not spray at low wind speeds less than 1 m/s Do not spray at high wind speeds more than 10 m/s 4. ULV spray equipment A good ULV sprayer uses rotary atomizers (spinning discs or rotating cages) to produce droplets in a small size range ( um). If droplets are too large or too small, control will be poor and insecticide wasted. ULV sprayers can be carried by an operator (portable) or mounted on 4x4 vehicle (vehicle-mounted sprayer), airplane or helicopter (aircraft-mounted sprayer). The principles of use are the same for all of them, but the scale and speed of operation are different. Portable sprayers For small areas (15 ha/day) For situations where a slow work rate is acceptable In rocks and hills On soft sands For single hopper bands only (not for swarm control) Vehicle-mounted sprayers For medium-sized areas (100 ha/day) For situations where a medium work rate is required For single bands Not recommended in rocks and hills Not recommended on soft sand Difficult to spray swarms Aircraft-mounted sprayers For large areas (5,000 ha/day or more) For situations where a fast work rate is required In rocks and hills On soft sand To control swarms (settled and flying) Not efficient for spraying single bands 7 Desert Locust Ground Control SOP 8 Desert Locust Ground Control SOP

6 5. Calibrating ULV spray equipment Spray equipment must be calibrated before the actual spraying takes place. What is calibration? The sprayer needs to be adjusted in order to apply the recommended amount of insecticide, in the right size spray droplets, to the right place. Calibration should always be carried out by using the actual insecticide that will be applied When do you calibrate spray equipment? When the sprayer is new When the insecticide formulation or concentration is changed When the volume application rate (VAR), track spacing or forward speed is changed Before the beginning of the campaign and on a daily basis during it How to calibrate a sprayer Step 1. Find the recommended dose of the insecticide (g a.i./ha) from the drum label, FAO Guidelines, etc. If it is given as litres/hectare, go to step 3. Step 2. Calculate the required Volume Application Rate (VAR). VAR (l/ha) = Recommended dose (g a.i./ha) Formulation concentration (g/l) Example: If the recommended dose for chlorpyrifos is 250 g a.i./ha and its concentration is 450 g/l what is the VAR? VAR (l/ha) = = 0.55 l/ha If the formulation concentration is expressed as percentage of weight to volume (% w/v), convert the concentration to g a.i/l by using the formula: Concentration (g a.i./l) = Concentration given x Example: If the concentration given for bendiocarb is 10%, then this must be converted by using the formula: 10 x 1000 Concentration in g a.i./l = 100 = 100 g a.i/l In short, multiply the given percentage concentration by Desert Locust Ground Control SOP 10 Desert Locust Ground Control SOP

7 Step 3. Calculate the required Flow Rate (FR). VAR (l/ha) x speed (km/h) x track spacing (m) FR (l/min) = 600 Example: What flow rate is required from a vehicle mounted sprayer moving at 10 km/h using a 30m track spacing in order to apply 100 g a.i./ha of bendiocarb 10% ULV? FR (l/min) = 1 (l/ha) x 10 (km/h) x 30 (m) 600 = 0.5 l/min It is important to remember that if one of the parameters (flow rate, track spacing or forward speed) is altered, then one or more of the others have to be changed in order to maintain the correct Volume Application Rate and Dose. If flow rate increases VAR increases (and vice versa) If track spacing increases VAR decreases (and vice versa) If forward speed increases VAR decreases (and vice versa) Example: If the wind becomes stronger, it might be possible to increase the track spacing to allow a faster work rate. In order to maintain the correct VAR and dose, either the spray forward speed must be decreased or the flow rate must be increased. In order to achieve a faster work rate from the wider track spacing, the flow rate must be increased, rather than the forward speed being decreased. How to measure the flow rate When measuring the flow rate from a ground-based sprayer, the collection technique can usually be used since the spray liquid can in most cases be collected easily as it is emitted: Step 1. Calculate the required flow rate (see page 11). Step 2. Make sure that the valves are in the correct position (refer to the sprayer manual). Step 3. Fill the sprayer, place a bucket under the atomizer and make sure to get rid of the air and that the tubes are full of liquid. Return the emitted insecticide to the tank. For vehicle-mounted sprayers, the engine should be running at normal operation speed to ensure that the correct voltage is being supplied to the battery and the sprayer. Step 4. Place a measuring cylinder under the sprayer atomizer and allow the insecticide to flow via a funnel for one minute. Only the pump should be switched on; never switch on the rotating atomizers. Step 5. Measure the volume of insecticide collected, then empty the cylinder back into the sprayer tank. Step 6. Adjust the flow rate to bring it closer to the required rate calculated previously. Repeat steps 4 and 5 until this rate has been achieved to within about 5% error. Step 7. When the required flow rate has been achieved, recheck it two more times to ensure that it is correct. 11 Desert Locust Ground Control SOP 12 Desert Locust Ground Control SOP

8 How to estimate work rate A rough estimate of the work rate can be calculated from the formula: Work rate (ha/h) = Forward speed (km/h) x track spacing (m) Note: this formula does not take into account the time required for turning at the end of each spray pass, which can be considerable for aircraft. Typical track spacings Recording and reporting Monitoring is very important in order to document the activities and to allow later analysis of the successes and failures of any campaign. Most of the information concerning the control operations and their efficacy and the efficiency of the campaign are covered in the FAO Spray Monitoring Form. The form should be completed together with the FAO Locust Survey & Control Form in order to include details on the location, rainfall, ecology and locusts. Both forms should be returned to the National Locust Unit headquarters as soon as possible for review. Any problems (lack of protective clothing, overdosing, poor efficacy, non-target effects, etc.) can be noted on the form so they can be addressed later. handheld spinning disk sprayers vehicle-mounted drift sprayers vehicle-mounted airblast sprayers aircraft-mounted sprayers 10 m 30 m 50 m 100 m Field staff recording the details of each control operation should use these forms 13 Desert Locust Ground Control SOP 14 Desert Locust Ground Control SOP

9 7. Cleaning, storing and disposal Spray equipment should always be clean and ready to use. Properly dispose empty containers. Always wear protective clothing while handling insecticides Sprayers Drain unused insecticide back into the original containers To clean the sprayer, put some kerosene or diesel into it and spray it over the target area or waste ground, away from water bodies or supplies used by people or livestock; never dump this liquid in one place such as a pit Carry out any repair or required maintenance Wash the outside of the sprayer with a cloth soaked in diesel or kerosene Store the cleaned sprayer safely in a store Insecticide storage Keep insecticide in original containers in a cool locked store to reduce deterioration caused by high temperatures Use older insecticides first (first-in-first-out system) Disposal of empty insecticide containers Clean empty insecticide containers three times inside and out with diesel or kerosene Collect the small volume of washings and dispose of by adding them to the insecticide in sprayer tanks during the next control operations or, if it is the end of the season, pour them into insecticide containers that are not full Never use empty containers for any other purpose than insecticides If they are to be recycled, they should be transported back to manufacturer Containers for disposal should be punctured, crushed and sent back to national authorities for appropriate disposal Refer to the FAO Desert Locust Guidelines 4. Control for more details 15 Desert Locust Ground Control SOP 16 Desert Locust Ground Control SOP

Phantom Air Blast Sprayer Conversion to Spinning Disk

Phantom Air Blast Sprayer Conversion to Spinning Disk Phantom Air Blast Sprayer Conversion to Spinning Disk Introduction The Phantom airblast sprayer is typical of airblast sprayers used in Desert Locust control. However, this sprayer (and similar types)

More information

Desert Locust Guidelines. 4. Control. Food and Agriculture Organization of the United Nations. H.M. Dobson. First edition 1992 Second edition 2001

Desert Locust Guidelines. 4. Control. Food and Agriculture Organization of the United Nations. H.M. Dobson. First edition 1992 Second edition 2001 4. Control H.M. Dobson First edition 1992 Second edition 2001 Food and Agriculture Organization of the United Nations Rome 2001 Control Preface PREFACE The Desert Locust plague of 1986-89 and the subsequent

More information

Guidelines for Pesticide Trials on Desert Locust Hoppers

Guidelines for Pesticide Trials on Desert Locust Hoppers Guidelines for Pesticide Trials on Desert Locust Hoppers FOOD AND AGRICULTURE ORGANIZATION OF THE UNITED NATIONS June 1991 (electronic version June 1999) Guidelines for pesticide trials on hopper bands

More information

Locusts have caused problems for quite some time

Locusts have caused problems for quite some time Locusts have caused problems for quite some time An Egyptian wall painting from 3425 years ago showing a Desert Locust on a papyrus flower I03a General information on locusts they are grasshoppers they

More information

NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF) UNIT PA6 HAND HELD APPLICATORS

NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF) UNIT PA6 HAND HELD APPLICATORS NPTC Registered Charity No. 1096429 ABBEY PARK, STARETON, WARWICKSHIRE, CV8 2LY Tel: 024 7685 7300 Fax: 024 7669 6128 Email: information@nptc.org.uk NPTC LEVEL 2 AWARD IN THE SAFE USE OF PESTICIDES (QCF)

More information

Pesticide Applicator Safety for Structural Applicators Calculations

Pesticide Applicator Safety for Structural Applicators Calculations Pesticide Applicator Safety for Structural Applicators Pesticide Applicator Safety for Structural Applicators Calculations 1 Calibrating Pesticide Application Equipment What You'll Learn! The purpose of

More information

A Review of the Current Knowledge on Pesticide Application Techniques Related to Desert Locust Control

A Review of the Current Knowledge on Pesticide Application Techniques Related to Desert Locust Control A Review of the Current Knowledge on Pesticide Application Techniques Related to Desert Locust Control Hans Dobson GCP/INT/651/NOR EMPRES Improving Pesticide Application Techniques for Desert Locust Control

More information

Cylinder Spray Adhesive - User s Guide

Cylinder Spray Adhesive - User s Guide Cylinder Spray Adhesive - User s Guide Technical Manual July 2017 3M Cylinder Spray Adhesives 3M has a full line of industrial-grade bulk spray adhesives, prepackaged in convenient, portable, and no-maintenance

More information

RH800 & 2000 BASIC OPERATIONS

RH800 & 2000 BASIC OPERATIONS RH800 & 2000 BASIC OPERATIONS 2 General information This manual contains technical information regarding Bayer SeedGrowth Equipment. Please read and understand these instructions completely before proceeding

More information

Calibrating Equipment for Aquatic Herbicide Application 1

Calibrating Equipment for Aquatic Herbicide Application 1 PI236 Calibrating Equipment for Aquatic Herbicide Application 1 F.M. Fishel 2 Introduction Calibration is the process of measuring and adjusting equipment performance (Figure 1). Before applying herbicides

More information

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6

COMMON PRECAUTIONS Data Sheet - Be Sure To Read Before Handling Page 1 of 6 COMMON PRECAUTIONS Page 1 of 6 These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution",

More information

DUAL ACTION SANDER MODEL NO: CAT121 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0211

DUAL ACTION SANDER MODEL NO: CAT121 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0211 DUAL ACTION SANDER MODEL NO: CAT121 PART NO: 3110877 OPERATION & MAINTENANCE INSTRUCTIONS LS0211 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product, please

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

Dropp UltraMAX CONTENTS

Dropp UltraMAX CONTENTS CONTENTS DIRECTIONS FOR USE (for use in Queensland, NSW and WA only)... 2 RESTRAINTS... 2 DIRECTIONS FOR USE TABLE (for use in Queensland, NSW and WA only)... 4 WITHHOLDING PERIOD... 4 EXPORT OF TREATED

More information

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212)

COATINGS SPRAY GUIDE Acrylics (210, 211, 211HT, and 212) This guide covers handling and airless spray application of American WeatherStar waterborne single component acrylic elastomeric coatings. These American WeatherStar products require only complete evaporation

More information

6800 Maintenance Instruction System Flush Procedure

6800 Maintenance Instruction System Flush Procedure Equipment Required FA74005 FA65318 FA900005 FA900003 Damper Drain Tube 6800 Cover Removal Tool Beaker 0.25 Litre Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves

More information

icon i150 / i350 Installation / Operation Manual

icon i150 / i350 Installation / Operation Manual i150 Concentrator i350 Concentrator icon i150 / i350 Installation / Operation Manual www.iconcentrator.com What You Will Need to Install Your icon In order to install your icon you will have to consider

More information

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT

Syringe, Distribution Valve and Infusion Pump Removal/Replacement ATTENTION SYRINGE REPLACEMENT ATTENTION SYRINGE REPLACEMENT Please read through the document completely before starting any repairs. Refer to the proper section in the service manual for complete removal and replacement procedures.

More information

Fire Ant Bait Broadcast Application Guide Prepared by: Bastiaan M. Drees, Director, Texas Imported Fire Ant Project

Fire Ant Bait Broadcast Application Guide Prepared by: Bastiaan M. Drees, Director, Texas Imported Fire Ant Project Fire Ant Bait Broadcast Application Guide Prepared by: Bastiaan M. Drees, Director, Texas Imported Fire Ant Project Selected edited text sections and illustrations were obtained from: "AMDRO Fire Ant Insecticide

More information

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment

Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment Product Manual B-Safety ClassicLine & PremiumLine Emergency Eyewash and Eye/Face Wash Equipment 1. Application Emergency eyewash and eye/face wash equipment are prescribed first aid installations for workplaces

More information

Standard Operating and Maintenance Instructions for Pumping System Model PS-150

Standard Operating and Maintenance Instructions for Pumping System Model PS-150 Standard Operating and Maintenance Instructions for Pumping System Model PS-150 High Pressure Equipment Company, LLC 2955 West 17th Street, Suite 6 PO Box 8248 Erie, PA 16505 USA 814-838-2028 (phone) 814-838-6075

More information

Instruction Manual Updated 5/26/2009 Ver. 2.0

Instruction Manual Updated 5/26/2009 Ver. 2.0 Bench-Mount Filter Press With Air Cylinder Part No. 140-35 Instruction Manual Updated 5/26/2009 Ver. 2.0 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300

More information

IK 12 VC: 7,5 ltr. Tank explanation

IK 12 VC: 7,5 ltr. Tank explanation IK 12 VC: 7,5 ltr. Tank explanation 1. Insecticide manufacturer instructions 1. Insecticide manufacturer instructions Insecticide Sachet: SYNGENTA ACTELLIC 300CS Bottle volume: 833 ml. Active ingredient:

More information

Portable Oil Lube Air Compressors

Portable Oil Lube Air Compressors Portable Oil Lube Air Compressors 8003631 8003632 0410149 8018968 8018940 Owner s Manual Read and understand operating instructions before use Safety definitions The information listed below should be

More information

then the work done is, if the force and the displacement are in opposite directions, then the work done is.

then the work done is, if the force and the displacement are in opposite directions, then the work done is. 1. What is the formula for work? W= x 2. What are the 8 forms of energy? 3. Write the formula for the following: Kinetic Energy Potential Energy 4. If the force and the displacement are in the same direction,

More information

REACTOR 40 MECHANICAL Configuration Guide

REACTOR 40 MECHANICAL Configuration Guide REACTOR 40 MECHANICAL Configuration Guide Important Safety Information WARNING See the Important Safety and Product Information guide in the product box for product warnings and other important information.

More information

ISOPA PRODUCT STEWARDSHIP PROGRAMMES. Walk the Talk TDI USERS. 1 Version09/06

ISOPA PRODUCT STEWARDSHIP PROGRAMMES. Walk the Talk TDI USERS. 1 Version09/06 ISOPA PRODUCT STEWARDSHIP PROGRAMMES Walk the Talk TDI USERS 1 Version09/06 2 Walk the Talk - TDI Users Content Essential data Good practice When things go wrong... Dialogue 3 TDI label information CLP

More information

UsER manual for Watersens ph -REDOX

UsER manual for Watersens ph -REDOX UsER manual for Watersens -REDOX Cl 8 1 2 6 3 3 7 7 4 4 4 4 Parts List 1 Redox Probe 1 x 2 PH Probe 1 x 5 Tube Weight 2 x 6 Connection Valve 1 x chlorine 3 Chlorine and Pumps 2 x 7 Dosing Valve 2 x 5 5

More information

Manual Actuated Boiler Blowdown Valves

Manual Actuated Boiler Blowdown Valves Manual Actuated Boiler Blowdown Valves Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Operation 5. Maintenance 6. Spare parts p.1 1. Safety

More information

Rotary Abreast Automatic Teat Sprayer User Manual. Technical Manual Revision 0.01

Rotary Abreast Automatic Teat Sprayer User Manual. Technical Manual Revision 0.01 Rotary Abreast Automatic Teat Sprayer Technical Manual 006911 Revision 0.01 Contents Contents... 2 Important information - read this first... 3 Icons... 3 1. Introduction... 4 2. Intended Use... 4 3. General

More information

Offshore Equipment. Yutaek Seo

Offshore Equipment. Yutaek Seo Offshore Equipment Yutaek Seo Flash Gas Compressor (East spar) Dehydration NGL recovery Slug catcher Separator Stabilization Booster compressor Gas export compression (Donghae-1 Platform) May 7 th Gas

More information

Airplane Flying Handbook. Figure 6-4. Rectangular course.

Airplane Flying Handbook. Figure 6-4. Rectangular course. Airplane Flying Handbook Rectangular Course Figure 6-4. Rectangular course. Normally, the first ground reference maneuver the pilot is introduced to is the rectangular course. [Figure 6-4] The rectangular

More information

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No

Operator s Manual. with Maintenance Schedule. Fourth Edition Second Printing Part No Operator s Manual with Maintenance Schedule Fourth Edition Second Printing Part No. 82297 Operator s Manual Fourth Edition Second Printing Important Read, understand and obey these safety rules and operating

More information

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C

Exercise 2-3. Flow Rate and Velocity EXERCISE OBJECTIVE C C C Exercise 2-3 EXERCISE OBJECTIVE C C C To describe the operation of a flow control valve; To establish the relationship between flow rate and velocity; To operate meter-in, meter-out, and bypass flow control

More information

Practice Test FOR GAS POSITIONS APTITUDE BATTERY

Practice Test FOR GAS POSITIONS APTITUDE BATTERY Practice Test FOR GAS POSITIONS APTITUDE BATTERY INTRODUCTION The purpose of this Practice Test is to help you prepare for the Gas Positions Aptitude Battery placement exercise. A sample of questions based

More information

OWNER S MANUAL FOR THE FOAM MARKER FM24. In-Ex PO Box Harts Road, Tiritea Palmerston North Ph: Fax:

OWNER S MANUAL FOR THE FOAM MARKER FM24. In-Ex PO Box Harts Road, Tiritea Palmerston North Ph: Fax: OWNER S MANUAL FOR THE FOAM MARKER FM24 In-Ex PO Box 1010 145 Harts Road, Tiritea Palmerston North Ph: 06 354 6060 Fax: 06 355 3199 1 SAFETY PRECAUTIONS Warnings are mandatory instructions to prevent serious

More information

Row / Distance from centerline, m. Fan side Distance behind spreader, m 0.5. Reference point. Center line

Row / Distance from centerline, m. Fan side Distance behind spreader, m 0.5. Reference point. Center line 1 Standardisation of test method for salt spreader: Air flow experiments Report 7: Effect of crosswind on salt distribution by Jan S. Strøm, Consultant Aarhus University, Engineering Centre Bygholm, Test

More information

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight

AC1810 / AC1810-A TECHNICAL SPECIFICATIONS. Operating Pressure psi ( kgs/cm²) [AC1810] Displacement. Net Weight Technical Specifications Operating Instructions Maintenance Information Troubleshooting Guide Parts Diagrams AC1810 / AC1810-A THE EVOLUTION OF PERFECTION CAUTION: Before attempting to use or service this

More information

(segmental) Instruction manual

(segmental) Instruction manual (segmental) Instruction manual Bromyard Industrial Estate, Bromyard, Herefordshire, HR7 4HS, UK Tel: + 44 (0) 1885 482397 Fax: + 44 (0) 1885 483043 E-mail: enquiries@micron.co.uk URL: http://www.micron.co.uk

More information

NS Cylinder Spray Adhesive - User s Guide

NS Cylinder Spray Adhesive - User s Guide NS Cylinder Spray Adhesive - User s Guide Technical Manual November 2017 NS Cylinder Spray Adhesives Is a full line of industrial-grade bulk spray adhesives, prepackaged in convenient, portable, and no-maintenance

More information

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL

NOVALYNX CORPORATION MODEL RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL NOVALYNX CORPORATION MODEL 260-2595 RAIN GAUGE CALIBRATOR INSTRUCTION MANUAL REVISION DATE: August 2018 Receiving and Unpacking Carefully unpack all components and compare to the packing list. Notify NovaLynx

More information

6900 Maintenance Instruction System Flush

6900 Maintenance Instruction System Flush Equipment Required FA74005 Damper Drain Tube FA16005 Cover Removal Tool FA900005 Beaker 0.25 Litre FA900003 Solvent Cleaning Bottle FA940021 Syringe Polypropylene 50 ml as required FA999045 Gloves Latex

More information

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment)

SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment) 3810050/5 IM-P381-01 CH Issue 5 SA121, SA122, SA123, SA128 and SA1219 Self-acting Temperature Control Systems (Knob Adjustment) Installation and Maintenance Instructions 1. Safety information 2. Use 3.

More information

INVESTIGATING HEART FAILURE

INVESTIGATING HEART FAILURE Luke Micallef name Heart Health: A Beginner s guide to cardiovascular disease Section INVESTIGATING HEART FAILURE Guide to Week 3 home practical Note: You will also need to download a copy of the worksheet

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

weber.cote Pool Paint

weber.cote Pool Paint weber.cote Pool Paint weber.cote Pool Paint weber.cote Pool Paint is a cement-based, integrally coloured, waterproof finish, specifically formulated for the revamping of marble plastered pools. Applied

More information

CUT OFF TOOL MODEL: CAT113

CUT OFF TOOL MODEL: CAT113 CUT OFF TOOL MODEL: CAT113 Part No: 3120135 ASSEMBLY & INSTRUCTION MANUAL LS0309 INTRODUCTION Thank you for purchasing this CLARKE product Before attempting to use the product, it is essential that you

More information

Product Safety Information

Product Safety Information Dwg. Tp2302 Dwg. Tp2301 Dwg. Tp2303 Dwg. Tp2304 Dwg. Tpa1751 45735685 Edition 1 June 2008 Rotary Air Sander, Polisher or Buffer Product Safety Information Save These Instructions MATCO TOOLS EN Product

More information

For Establishing and Maintaining Your Spa using PROtech Spa Chemicals

For Establishing and Maintaining Your Spa using PROtech Spa Chemicals Spa Care For Establishing and Maintaining Your Spa using PROtech Spa Chemicals QUICK START Add water up to the level recommended by the manufacturer of your spa and let the pump circulate for at least

More information

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR

MODEL NUMBER: P-A AUTOMATIC PORTABLE COMPRESSOR MODEL NUMBER: 45043-450P-A AUTOMATIC PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and

More information

Altosid PELLETS Mosquito Growth Regulator

Altosid PELLETS Mosquito Growth Regulator 03-DEC-2008 2008-4790 Altosid PELLETS Mosquito Growth Regulator An Insect Growth Regulator to Prevent Adult Mosquito Emergence RESTRICTED GUARANTEE: (S)-Methoprene 4.25% REGISTRATION NO. 21809 PEST CONTROL

More information

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents

HOT OILING OPERATIONS ALL HSE PRC 172. Approved By: Manager, HSE Performance Assurance. Table of Contents Owner: HSE Performance Assurance ALL HSE PRC 172 Approved By: Manager, HSE Performance Assurance Retention Code: CG01 CA Revised: March 2015 Review Frequency: Five years or less Table of Contents 1.0 Purpose...

More information

Test pumps. Pressure sources. Good reasons for proper and reliable calibration

Test pumps. Pressure sources. Good reasons for proper and reliable calibration Test pumps Pressure is one of the most commonly measured quantities in engineering, which is why exact and reliable pressure measurement is especially important. However, the characteristics of the even

More information

SURVEYING THE HAZARDOUS MATERIALS INCIDENT

SURVEYING THE HAZARDOUS MATERIALS INCIDENT HAZARDOUS MATERIALS TECHNICIAN MANIPULATIVE SKILL OBJECTIVES SURVEYING THE HAZARDOUS MATERIALS INCIDENT 1. Given three hazardous materials, one of which is a solid, one a liquid and one a gas, and the

More information

Instructions for SILEX 1C Mixed bed cartridge filter

Instructions for SILEX 1C Mixed bed cartridge filter D01B-30A-UK1 January 2017 Instructions for SILEX 1C Mixed bed cartridge filter With conductivity sensor Gravity flow or pressure installation SILHORKO-EUROWATER A/S Phone +45 86 57 12 22 DK-8660 Skanderborg

More information

Pneumatic Oil Extractor

Pneumatic Oil Extractor Pneumatic Oil Extractor Operational Manual Model No.: JA1041OD 1 Safety Warnings and Precautions WARNING: When using tool, basic safety precautions should always be followed to reduce the risk of personal

More information

Ethalfluralin Manufacturing Concentrate

Ethalfluralin Manufacturing Concentrate (blending booklet) Ethalfluralin Manufacturing Concentrate GROUP 3 HERBICIDE MANUFACTURING INSTRUCTIONS FOR BLENDING PLANT OPERATORS Blending Plant Operators must provide the booklets entitled Directions

More information

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr

Installation and Maintenance Manual. ECO Filtration Unit with 6-way-Top-Mount-Valve. Art. Nr Installation and Maintenance Manual ECO Filtration Unit with 6-way-Top-Mount-Valve Art. Nr. 300100 300101 300102 Important Details: - Using of this filtration unit for swimming pools and its guard band

More information

Chapter 2 Preparations for Tank Cleaning Work

Chapter 2 Preparations for Tank Cleaning Work Chapter 2 Preparations for Tank Cleaning Work Preparatory Procedures for Tank Cleaning Work Make preparations for tank cleaning work according to the procedures given below. 1. Formulating the tank cleaning

More information

Risk Analysis and Hazard Reduction Report V1.0

Risk Analysis and Hazard Reduction Report V1.0 Risk Analysis and Hazard Reduction Report V1.0 2 Contents 1. Definitions and Risk Classifications 3 2. Risk and Hazard reduction associated with Personnel 4-5 3. Risk and Hazard reduction associated with

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants

Atmospheric Hazards. Hazardous Atmosphere 3/29/2017. Oxygen deficiency and enrichment Flammable gases and vapors Toxic contaminants 2017 Wisconsin Safety Council Safety & Health Conference, Presentation by Tim Gackle, OSHA Training Institute April 11, 2017 Atmospheric Hazards Oxygen deficiency and enrichment Flammable gases and vapors

More information

Fire and Rescue Service Operational Guidance Equipment Manual Environment Protection Equipment Environment Agency Grab Pack Table of Contents 1 Genera

Fire and Rescue Service Operational Guidance Equipment Manual Environment Protection Equipment Environment Agency Grab Pack Table of Contents 1 Genera Fire and Rescue Service Operational Guidance EM-XXX Equipment Manual Environment Agency Grab Pack Operational Guidance Fire and Rescue Service Operational Guidance Equipment Manual Environment Protection

More information

Instruction Manual. Publication Part Number: 9009 Revision: 2

Instruction Manual. Publication Part Number: 9009 Revision: 2 Instruction Manual Publication Part Number: 9009 Revision: 2 CONTENTS Page Safety...... 4 Operator protection...... 5 Preparing for spraying...... 5 Before spraying for the first time...... 6 Mixing,

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

"DEALING WITH HAZARDOUS SPILLS"

DEALING WITH HAZARDOUS SPILLS PRESENTER'S GUIDE "DEALING WITH HAZARDOUS SPILLS" Part of the "SAFETY MEETING KIT" Series Quality Safety and Health Products, for Today...and Tomorrow OUTLINE OF MAJOR PROGRAM POINTS OUTLINE OF MAJOR PROGRAM

More information

Flexi-pro Aerosol Delivery System (FADS) Manual

Flexi-pro Aerosol Delivery System (FADS) Manual 603-000-010 Flexi-pro Aerosol Delivery System (FADS) Manual Troubleshooting Troubleshooting Problem Solution Problem Solution About Flexi-pro Aerosol Delivery System is able to adapt to a variety of traditional

More information

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS

6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS 6000 SERIES OF PNEUMATIC DEADWEIGHT TESTERS USER MANUAL -1- SI-BARNET DEADWEIGHT TESTER 6000 SERIES Release: S31-0250 Revision: A Date: 05/08/03 MANUFACTURED BY: GE RUSKA RUSKA INSTRUMENT CORPORATION 10311

More information

CeCeCe TM OTHER. Active ingredient: chlormequat chloride g /

CeCeCe TM OTHER. Active ingredient: chlormequat chloride g / Reg. No. L3068 Act No. 36 of 1947 A water soluble solution plant growth regulator to reduce lodging and wind damage in wheat and excessive shoot growth in pears. Active ingredient: chlormequat chloride...750

More information

Research Laboratory Safety Self-Inspection: Chemical & Physical Safety Checklists

Research Laboratory Safety Self-Inspection: Chemical & Physical Safety Checklists Research Laboratory Safety Self-Inspection: Chemical & Physical Safety Checklists Principal Investigator: Lab Building: Lab Rooms: Department: Inspector Name: Inspection Date: Question Y N NA Comments

More information

444C DUAL PERFORMANCE VALUE PACK

444C DUAL PERFORMANCE VALUE PACK (Chrome) PART NO. 44432 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL

More information

Joules PRODUCT BENEFITS

Joules PRODUCT BENEFITS A suspension concentrate formulation containing 500 g/l (40.2% w/w) chlorothalonil. A protectant fungicide for disease control in winter and spring wheat and winter and spring barley. PRODUCT BENEFITS

More information

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO 400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

DROP SPREADER CALIBRATION PROCEDURES

DROP SPREADER CALIBRATION PROCEDURES DROP SPREADER CALIBRATION PROCEDURES The accurate application of lawn materials requires proper calibration of lawn spreaders of which there are two basic types: drop spreaders rotary spreaders Most professional

More information

Visit:

Visit: CORAL CLASSIC SPA START UP INSTRUCTIONS Remove the filter from the spa, see page 8 in your user manual. Place a hose in the filter box to fill the spa with water, see page 7 in your user manual. Remove

More information

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS

UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Part No. 88847 Revised: August 2004 UNIVERSAL GAS FRYER Instruction Manual Model #8065NS Cincinnati, OH 45241-4807 USA GAS SAFETY PRECAUTIONS OPERATING INSTRUCTIONS UNPACKING AND ASSEMBLY After unpacking

More information

Grade 7 Science Related Reading/Materials. Name: Materials Gr7. Class: Date: States of Matter

Grade 7 Science Related Reading/Materials. Name: Materials Gr7. Class: Date: States of Matter Name: Class: Date: Grade 7 Science Related Reading/Materials States of Matter Materials Gr7 You ve just walked home on one of the coldest days of the year. A fire is blazing in the fire place. And there

More information

Thank you for purchasing your new Empire Reloader B Sound-Activated 3-Speed Paintball Hopper!

Thank you for purchasing your new Empire Reloader B Sound-Activated 3-Speed Paintball Hopper! Thank you for purchasing your new Empire Reloader B Sound-Activated 3-Speed Paintball Hopper! Should you require any technical assistance on the use of this product, or if your product needs servicing,

More information

Moving Fluids Concept and Theory

Moving Fluids Concept and Theory Moving Fluids Concept and Theory Graco, Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 1995 Graco Inc. Form No. 321-037 12/95 Rev 2 SL Training 11/14 Understanding Your Customer s Situation Characteristics

More information

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only)

42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 42045 Heavy Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor Only) 42047 Heavy Duty ADA Base Model Kit: 110/145 PSI (ADA Compressor Only) 45052 Constant Duty ADA Base Model Kit: 85/105 PSI (ADA Compressor

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

Owner s Manual AMERICAN. LiquaGen 5 Stage (RO/DI) Aquarium Reef System. YEAR Y 1

Owner s Manual AMERICAN. LiquaGen 5 Stage (RO/DI) Aquarium Reef System.   YEAR Y 1 Owner s Manual A NT HENTI AMERICAN Y 1 UT C WARR AR A 1-Y E LiquaGen 5 Stage (RO/DI) Aquarium Reef System YEAR MANUFACTURER WARRANTY Welcome to the LiquaGen experience and thank you for purchasing our

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

MODEL NUMBER: P PORTABLE COMPRESSOR

MODEL NUMBER: P PORTABLE COMPRESSOR MODEL NUMBER: 30033-300P PORTABLE COMPRESSOR IMPORTANT: It is essential that you and any other operator of the product read and understand the contents of this manual before installing and using this product.

More information

400C & 450C DUAL PERFORMANCE VALUE PACKS

400C & 450C DUAL PERFORMANCE VALUE PACKS (Chrome) PART NO. 40013 (Silver) PART NO. 45012 (Chrome) PART NO. 45013 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before

More information

INSTRUCTION MANUAL. Gas Salamander

INSTRUCTION MANUAL. Gas Salamander INSTRUCTION MANUAL Gas Salamander This manual contains important information regarding your unit. Please read this manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply

More information

2B Technologies, Inc.

2B Technologies, Inc. 2B Technologies, Inc. An InDevR Company Technical Note No. 018 Cleaning Procedure for Model 202 Ozone Monitor Date: 22 September 2008; Updated 8 July 2016 Author: John Birks Summary: It is recommended

More information

ITW RANSBURG REA AND VECTOR

ITW RANSBURG REA AND VECTOR ITW RANSBURG REA AND VECTOR APPLICATORS TECHNICAL MANUAL (Replaces IL-246-A) January - 2008 ELECTROSTATIC TIC SPRAY TECHNIQUES IMPORTANT ANT: : Before using this equipment, carefully read SAFETY PRECAUTIONS,

More information

MAPP PCS No Syngenta UK Limited CPC 4, Capital Park, Fulbourn, Cambridge CB21 5XE Tel: Cambridge (01223)

MAPP PCS No Syngenta UK Limited CPC 4, Capital Park, Fulbourn, Cambridge CB21 5XE Tel: Cambridge (01223) L1042628 GBRI/05W PPE 4095335 1257/17 BANNER MAXX ll is an emulsifiable concentrate formulation containing 162 g/l propiconazole A broad spectrum foliar fungicide with systemic properties for control of

More information

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES EXTREME SERIES PART NO. 45043 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS

More information

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES

450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES 450P- RV AUTOMATIC PORTABLE COMPRESSOR EXTREME SERIES PART NO. 45053 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing

More information

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road

PROPORTIONING VALVE. Model 150 INSTRUCTION MANUAL. March 2017 IMS Company Stafford Road PROPORTIONING VALVE Model 150 INSTRUCTION MANUAL March 2017 IMS Company 10373 Stafford Road Telephone: (440) 543-1615 Fax: (440) 543-1069 Email: sales@imscompany.com 1 Introduction IMS Company reserves

More information

Series IRV1000/2000/3000

Series IRV1000/2000/3000 CAT.ES60-16 A Regulator Series /2000/3000 Allows adjustment of vacuum line pressure Regulator Series /2000/3000 3 sizes offered in the series Variations have been expanded to three sizes from only one

More information

Hammar LifeJacket Inflator

Hammar LifeJacket Inflator Hammar LifeJacket Inflator Product information STandard Model (M1/A1) Important for Users Sales LifeJacket (PFD) Service Product Information Recharge instruction Why you should choose this model the hammar

More information

WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES

WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES WMO LABORATORY INTERCOMPARISON OF RAIN INTENSITY GAUGES Christophe ALEXANDROPOULOS and Muriel LACOMBE Météo-France, Direction des Systèmes d Observation, BP 202-78195 Trappes France christophe.alexandropoulos@meteo.fr

More information

Bestox pc50 RESIDUAL INSECTICIDE

Bestox pc50 RESIDUAL INSECTICIDE POISON KEEP OUT OF REACH OF CHILDREN READ SAFETY DIRECTIONS BEFORE OPENING OR USING Bestox pc50 RESIDUAL INSECTICIDE ACTIVE CONSTITUENT: 50 g/l ALPHA-CYPERMETHRIN GROUP 3A INSECTICIDE For knockdown and

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

SVEA II GSM Connector User Manual

SVEA II GSM Connector User Manual www.possio.com SVEA II GSM Connector User Manual 1. Introduction Before using SVEA II please read this manual carefully and keep it for future reference. SVEA II GSM Connector is a device for realization

More information