Draught Academy. Name. Date _

Size: px
Start display at page:

Download "Draught Academy. Name. Date _"

Transcription

1 Draught Academy Name Date

2 BBS Systems Vancouver 7630 Winston St. Burnaby, BC V5A 2H4 Local: Toll Free: Fax: BBS Systems Calgary rd Ave SE Calgary, Alberta T2H 2E7 Toll Free: Fax: BBS Systems Edmonton th Ave NW Edmonton, Alberta T6B 2X9 Toll Free: Fax: BBS Systems Red Deer Red Deer, Alberta Toll Free: Fax: BBS Systems Victoria 4250B Commerce Circle Victoria BC V8Z 4M2 Local: Fax:

3 Section 1 Keg Storage and Dispense Temperature

4 TEMPERATURE & STORING DRAUGHT BEER Pasteurized vs. Non-pasteurized Keg Beer Shelf Life

5 TEMPERATURE & STORING DRAUGHT BEER The most common service or trouble call usually relates to temperature. CO2 stays in solution at the correct temperature. As the temperature rises the CO2 in the beer expands and breaks out of solution. STORE AND POUR AT 38 F (3 C)

6 TEMPERATURE & STORING DRAUGHT BEER The most common service or trouble call usually relates to temperature. STORE AND POUR AT 38 F (3 C)

7 Section 2 Dispense Gas 30% CO2 70% N2 100 % CO2

8 Dispense Gas Selection

9

10 Air Compressors MUST NOT be used to dispense Beer! Problem: Compressed air alters the integrity of draft beer.

11 Standard CO2 Cylinder 100 % CO2 For Short Distances (Direct Draw Systems)

12 Mixed Gas Cylinder CO2 & Nitrogen (aka Beer Gas ) For Long Distances (Long Draw Systems) Mixed gas at 30% CO2 & 70% Nitrogen meets the Guinness specification only for beer dispense and does not contain the required amount of CO2 for most products 30% CO2 70% N2

13 DOES THE BLEND REALLY MATTER? 30 % CO2 & 70% N2:

14 CO2 Content (vol/vol) MCDANTIM - BLEND SELECTION CHARTS Keg Pressure (psi)

15 Mixed Gas Blender For Long Distances (Long Draw Systems)

16 Mixed Gas Blender

17 VALUE ADDED OPTIONS Nitrogen Generator Lager Stout

18 Notes:

19 Section 3 System Components BREWMASTER TWO Foil Wrap Moisture Barrier Wrap Glycol Outgoing Supply Line Glycol Return Line

20 Keg M- SYSTEM

21 Keg Sizes or 20 Litre or 30 Litre 58 Litre 30 Litre

22 Primary Regulator Pressure Relief Valve CO2 Nut CO2 Inlet Nipple CO2 Teflon Washer N2 Inlet Nipple Button-Spring Retainer Shut-Off Valve Seat Spring Seat Capsule Assembly Diaphragm Assembly Bonnet Gasket Bonnet Spring Bonnet Assembly

23 Primary Regulator Cylinder Valve: Turn counter clockwise and open valve completely. Keg Pressure Gauge Cylinder Pressure Gauge Adjusting Screw: Turn clockwise to increase pressure. Gas Flow To Primary Regulator From Gas Source Gas Flow To Coupler (or) Secondary From Primary Regulator

24 Secondary Regulator Type Secondary Regulator - CO2 or Mixed Gas Installation Wall mount bracket Dimensions Performance Output Pressure Gauge Capacity 4-3/4" wide x 6-7/8" high x 4-3/4" deep 1 Pressure / 1 Keg 0-60 PSI, for accurate keg pressure SCFM 3.5 Max Outlet Barb 3/8" O.D. (To fit 5/16" I.D. Gas Hose)

25 Pressure Line Secondary Regulator

26 Keg Coupler Check Ball Retainer Check Ball Probe Probe Seal Handle Assembly Probe O-Ring Check Valve Hex Nut Hinge Pin Pressure Relief Valve Assembly Hose Nipple Body Washer

27 Keg Coupler Systems

28 Vinyl Beer Tubing (drop down line) Wall Bracket

29 FOB

30 FOB

31

32

33

34 Beer Lines

35 Trunk Line BREWMASTER TWO Glycol Return Line Insulation Foil Wrap Moisture Barrier Wrap Glycol Outgoing Supply Line

36 Glycol Cooled System Glycol Deck (or Power Pack)

37 Glycol Deck

38 The Refrigeration Cycle The refrigerator in your kitchen uses a cycle that is similar to the one described in the previous section. But in your refrigerator, the cycle is continuous. In the following example, we will assume that the refrigerant being used is pure ammonia, which boils at -27 degrees F. This is what happens to keep the refrigerator cool: 1.The compressor compresses the ammonia gas. The compressed gas heats up as it is pressurized (orange). 2.The coils on the back of the refrigerator let the hot ammonia gas dissipate its heat. The ammonia gas condenses into ammonia liquid (dark blue) at high pressure. 3.The high-pressure ammonia liquid flows through the expansion valve. You can think of the expansion valve as a small hole. On one side of the hole is high-pressure ammonia liquid. On the other side of the hole is a low-pressure area (because the compressor is sucking gas out of that side). 1.The liquid ammonia immediately boils and vaporizes (light blue), its temperature dropping to -27 F. This makes the inside of the refrigerator cold. 2.The cold ammonia gas is sucked up by the compressor, and the cycle repeats. By the way, if you have ever turned your car off on a hot summer day when you have had the air conditioner running, you may have heard a hissing noise under the hood. That noise is the sound of high-pressure liquid refrigerant flowing through the expansion valve.

39 Draught Towers Air Cooled

40 Draught Towers Glycol Cooled

41 Draught Towers Kool-Rite Patent Pending Double D Cold Block Tower Body Housing Product Path Thermal Foil Tape Leak Proof Foam Insulation Double O-Rings Copper Coolant Line Foam Insulation Stainless Steel Barb End

42 Faucet Common Replacement Parts Part Description Reason For Replacement 4318 Coupling Washer Leaking at coupling nut 4324 Shaft Washer Leaking at spout 4308 Friction Washer Tension on tap marker Faucet Knob Lever Collar Lever Bonnet Friction Washer Ball Washer Lever Shaft Nut Shaft Seat Shaft Coupling Washer Body

43 Faucet Faucet Open: Dispensing Faucet Closed: Flow Stops Vent Holes

44 The PERFECT POUR always use a BEER CLEAN glass!

45 Notes:

46 Notes:

47 Section 4 Draught Systems

48 DIRECT DRAW SYSTEM - DISPENSING UP TO 5 FEET Self-Contained Keg Storage & Dispensing

49 DIRECT DRAW SYSTEM - DISPENSING UP TO 5 FEET

50 DIRECT DRAW SYSTEM - DISPENSING DIRECTLY THROUGH WALL Walk-In Cooler System Evaporator Unit Shanks Secondary Regulators 50 Liter Cleaning Bottle Gas Line Coupler Keg Stacker CO2 Purifier Kegs Beer Hose CO2 Regulator CO2 Cylinder

51 LONG DRAW DRAUGHT BEER SYSTEM GLYCOL / FREON COOLED - DISPENSING UP TO 500 FEET Pressure Side Beer Side

52 Notes:

53 Section 5 System Balance & Restriction

54 FUNDAMENTALS

55 AFFECTS ON TEMPERATURE & APPLIED PRESSURE

56 RESISTANCE + 1/2 lb/foot Gravity Altitude 1/2 lb/foot

57 BEER LINE RESISTANCE

58 DIRECT DRAW SYSTEM BALANCE

59 LONG DRAW SYSTEM BALANCE

60 LONG DRAW SYSTEM BALANCE BALANCE THE FOLLOWING SYSTEM:

61

62 Notes:

63 Section 6 Line Cleaning

64 WHY ARE WE CLEANING? Ingredients in the beer are attracted to the surface of the tubing. Biofilm forms over the surface of the tubing, making it easier for micro-organisms to adhere to the tubing. Micro-organisms are transported to the surface of the tubing. Micro-organisms are then held at the surface. Micro-organisms in the biofilm release CO2 and off-flavors into the beer, breaking off in clumps causing cloudy beer.

65 WHAT ARE THE ELEMENTS WE ARE CLEANING FOR?

66 CLEANING CHEMICALS

67 CLEANING METHODS Pressurized Cleaning

68 CLEANING METHODS Pressurized Cleaning

69 CLEANING METHODS Recirculating Pump Cleaning UP TO 80X MORE EFFECTIVE!

70 Recirculating Pump Cleaning UP TO 80X MORE EFFECTIVE!

71 Recirculating Pump Cleaning UP TO 80X MORE EFFECTIVE!

72 Recirculating Pump Cleaning UP TO 80X MORE EFFECTIVE!

73 Line Cleaning Checklist 30 DAY

74 Notes:

75

76 A Beer Clean glass is the first step to serving an enticing and appetizing glass of beer. SHEETING TEST A properly cleaned glass will shed water evenly in unbroken sheets. On a glass with invisible film, water will break up and form droplets on the surface of the glass.

77 SALT TEST In a properly cleaned glass, salt sprinkled on the interior of a wet glass will adhere evenly. If not properly cleaned, salt will fall to the bottom or adhere in a random pattern. Salt will not stick wherever a greasy film is present.

78 HEAD RETENTION BUBBLE TEST A properly cleaned glass will form a thick, tightly-knit, creamy head. The beer will be sparkling-clear and free of bubbles. A glass that is not properly cleaned will have loose, large bubbles (fish eyes) that will cause the head to disappear within ten to sixty seconds. Bubbles will visibly rise from the bottom of the glass and adhere to the sides.

79 LACING TEST In a properly cleaned glass, foam will adhere to the inside of the glass, forming a parallel ring pattern (lacing) as each sip of beer is taken. In a glass that is not properly cleaned, foam (if there is any) will adhere to the glass in a loose, random pattern or may not adhere at all.

80 Notes:

81

82 Check Pour Check Pour

83 Notes:

ASSEMBLY & USE MANUAL

ASSEMBLY & USE MANUAL DRAFT BEER DISPENSER ASSEMBLY & USE MANUAL - Stout Beers SAFETY FIRST! Read instructions completely Mixed gas can be dangerous. Flush chemical out of beer hose completely before re-tapping keg. Micro Matic

More information

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM

FOR INSTALLING CO 2 BLENDER KIT (P/N IN BEER SYSTEM IMI CORNELIUS INC One Cornelius Place Anoka, MN 55303-623 Telephone (800) 238-3600 Facsimile (612) 22-326 INSTALLATION INSTRUCTIONS FOR INSTALLING CO 2 BLENDER KIT (P/N 111612000 IN BEER SYSTEM SECONDARY

More information

INSTALLATION and OPERATION INSTRUCTIONS

INSTALLATION and OPERATION INSTRUCTIONS INSTALLATION and OPERATION INSTRUCTIONS FLOJET Beer Pump Panels MODEL NO. 66134-1 66134-2 66134-3 66134-4 IMPORTANT INFORMATION This manual has been prepared to assist you in the operation of Perlick Beer

More information

System Design - Understanding and Optimizing Your Current or Future Draught System. Jeff Bell MillerCoors On Premise Quality October 5 th, 2017

System Design - Understanding and Optimizing Your Current or Future Draught System. Jeff Bell MillerCoors On Premise Quality October 5 th, 2017 System Design - Understanding and Optimizing Your Current or Future Draught System Jeff Bell MillerCoors On Premise Quality October 5 th, 2017 Agenda Importance of a Balanced System Effects of an Un-Balanced

More information

Installation Manual. Remote Draft Beer Systems

Installation Manual. Remote Draft Beer Systems Installation Manual Remote Draft Beer Systems Glastender, Inc. 5400 North Michigan Road Saginaw, MI 48604-9780 800.748.0423 989.752.4275 Fax 989.752.4444 www.glastender.com Rev. 08-15-06 2006 Glastender,

More information

Chemical Injection Technologies Installation/Service Bulletin

Chemical Injection Technologies Installation/Service Bulletin Bulletin 4002 Chemical Injection Technologies Installation/Service Bulletin SUPERIOR Series CL-16/26/56 Automatic Switchover Gas Chlorinator - Installation & Operation IMPORTANT!! READ THESE PRECAUTIONS

More information

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1.

SPECIFICATIONS Type: Twin stack, single phase Tank: 4 gallon Air Output: PSI; PSI Max PSI: 125 PSI HP: 1. 2 GALLON TWIN STACK AIR COMPRESSOR Model: 9526 DO NOT RETURN TO STORE. Please CALL 800-348-5004 for parts and service. CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or

More information

V43 Pressure Actuated Water Regulating Valve

V43 Pressure Actuated Water Regulating Valve FANs 125, 121 Product/Technical Bulletin V43 Issue Date 0996 V43 Pressure Actuated Water Regulating Valve The V43 Pressure Actuated Water Regulating Valves are designed to regulate water flow for water-cooled

More information

Instruction Manual Updated 7/26/2011 Ver. 2.2

Instruction Manual Updated 7/26/2011 Ver. 2.2 4-Unit Model MB HTHP Filter Press #171-50-4: 115-Volt #171-51-4: 230-Volt Instruction Manual Updated 7/26/2011 Ver. 2.2 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele:

More information

Air Operated Hydraulic Pumping Systems to 50,000 psi

Air Operated Hydraulic Pumping Systems to 50,000 psi High Pressure Equipment Air Operated Hydraulic Pumping Systems to 50,000 psi PS-10: 10,000 psi PS-20: 20,000 psi PS-30: 30,000 psi PS-40: 40,000 psi PS-50: 50,000 psi PS-90: 90,000 psi High Pressure air

More information

XpressFill XF2500 Counter Pressure Filler. Operating Instructions

XpressFill XF2500 Counter Pressure Filler. Operating Instructions XpressFill XF2500 Counter Pressure Filler Operating Instructions ii XPRESSFILL Systems LLC lling machine. ank you for choosing our handcrafted bottle filler as the technology to bottle your passion. We

More information

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw.

Premium Series. Economical Price & Reliable Performance. High Quality. Rust-Resistant. Long Life. Tamper-Resistant locking Screw. Premium Series High Quality Forged Brass Body Rust-Resistant Nickel Plated Finish Long Life Corrosion Resistant Valve Seat Economical Price & Reliable Performance Tamper-Resistant locking Screw Reduces

More information

FisherPak Instructions

FisherPak Instructions FisherPak Instructions Installation and Start-Up Procedures 2 FisherPak Dip Tape Level Gauge Operating Instructions 3 Trouble Shooting Guide 3 FisherPak Disconnection Procedure 4 Rupture Disk Replacement

More information

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator)

Binks SG-2 Plus TM 2 QT. PRESSURE CUPS Model No (Standard) Model No (with OscillatingAgitator) INTRODUCTION Binks SG-2 Plus TM Pressure Cup is ideal for component spraying and industrial applications where small batch production spraying is required. The 2 qt. capacity is sufficient to complete

More information

CSA Sample Draw Aspirator Adapter Operator s Manual

CSA Sample Draw Aspirator Adapter Operator s Manual 30-0951-CSA Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0367 Revision: 0 Released: 4/30/15 www.rkiinstruments.com WARNING Read and understand this instruction manual before operating

More information

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES STYLE No. UNWD11 Universal Traditional One Hole Instant Hot Water Dispenser with Metal Lever Handle STYLE No. UNWD31 Universal Industrial One Hole Instant Hot Water Dispenser with Metal Lever Handle STYLE

More information

RK-IR Sample Draw Aspirator Adapter Operator s Manual

RK-IR Sample Draw Aspirator Adapter Operator s Manual 30-0951RK-IR Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0018RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS

FILTER REGULATORS MODEL NO: CAT155 & CAT156 FITTING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS FILTER REGULATORS MODEL NO: CAT155 & CAT156 PART NO: 3120169 & 3120170 FITTING & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0117 INTRODUCTION Thank you for purchasing this CLARKE Filter/Regulator.

More information

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system

Bulletin TCR-104 & 109 Filling and adding to the Glycol pressure system Bulletin 061013 TCR-104 & 109 Filling and adding to the Glycol pressure system 1. Glycol System and air On this model the glycol system is a closed system, the glycol is not exposed to the air. No external

More information

K Page 1 of 48 Air Intake - Pg. 17

K Page 1 of 48 Air Intake - Pg. 17 K532-53168 Page 1 of 48 Air Intake - Pg. 17 Ref # Part Number Qty Description 24 25 041 06-S 1 Gasket, elbow 25 48 054 09 1 Elbow, air cleaner Discontinued not available at Kohler Co. 35 277116-S 1 Brace,

More information

Installation, Operation and Maintenance Manual for Back Pressure Regulator

Installation, Operation and Maintenance Manual for Back Pressure Regulator Installation, Operation and Maintenance Manual for Back Pressure Regulator Model 8860 2009 Groth Corporation IOM-8860 Rev. B 12541 Ref. ID: 95565 Page 2 of 13 Table of Contents I. INTRODUCTION 3 II. DESIGN

More information

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane

Detector Carrier Gas Comments Detector anode purge or reference gas. Electron Capture Nitrogen Maximum sensitivity Nitrogen Argon/Methane Gas requirements Gases for packed columns The carrier gas you use depends upon the type of detector and the performance requirements. Table 520-1 lists gas recommendations for packed column use. In general,

More information

XpressFill XF4500 Counter Pressure Filler. Operating Instructions

XpressFill XF4500 Counter Pressure Filler. Operating Instructions XpressFill XF4500 Counter Pressure Filler Operating Instructions ii XPRESSFILL Systems LLC lling machine. ank you for choosing our handcrafted bottle filler as the technology to bottle your passion. We

More information

Product Information News

Product Information News Product Information News MMR SECOND STAGE REGULATOR VALVE CORE MSA has changed its recommended rebuilding of the MMR Second Stage Regulator s bypass sleeve assembly during the annual inspection. Based

More information

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Gas powered stop valves, type GPLX REFRIGERATION AND AIR CONDITIONING. Technical leaflet Gas powered stop valves, type GPLX 80-150 REFRIGERATION AND AIR CONDITIONING Technical leaflet Technical leaflet Gas powered stop valves, type GPLX 80-150 Contents Page Introduction........................................................................................3

More information

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7

!!!! SERVICE MANUAL PRESSURE POT 2 GALLON. Service Manual: LT Washington St 931 Progress Ave., #7 EXEL North America, Inc. EXEL Industrial Canada, Inc. 1310 Washington St 931 Progress Ave., #7 West Chicago, IL 60185 Scarborough ONT, M1G 3V5 Ph : (800) 573 5554 Ph : (800) 450 0655 Fx : (800) 664 1511

More information

ABRASIVE REGULATOR II

ABRASIVE REGULATOR II ABRASIVE REGULATOR II 13096 Abrasive Regulator II TABLE OF CONTENTS Contact Information and Customer & Technical Service... 1 1 Introduction... 1 2 Abrasive Regulator... 1 Description:... 1 2.1 Regulator

More information

Refrigerant Gases Valves

Refrigerant Gases Valves Refrigerant Gases Valves RUS series Single Outlet Compact Refrigerant Recovery Valves 46 RDU series Diaphragm Packless Multivalves for Refrigerant Gases 47 RBV series Single Outlet Diaphragm Packless Valves

More information

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8" and 1/4" PTF Port Sizes. Air line equipment.

ALE-40. R06 Miniature Brass Body Regulator. Water and Compressed Air Service 1/8 and 1/4 PTF Port Sizes. Air line equipment. Air line equipment R Miniature Brass Body Regulator Water and Compressed Air Service 1/" and 1/" PTF Port Sizes Compact design, corrosion resistant construction Brass body with choice of plastic or brass

More information

INSTALLATION GUIDELINES

INSTALLATION GUIDELINES STYLE No. UNWD10 Universal Traditional One Hole Instant Hot and Filtered with Metal STYLE No. UNWD30 Universal Industrial One Hole Instant Hot and Filtered cold Water Dispenser with Metal STYLE No. UNWD50

More information

ABRASIVE REGULATOR II

ABRASIVE REGULATOR II ABRASIVE REGULATOR II 13096 Abrasive Regulator II TABLE OF CONTENTS 1 Introduction... 1 2 Abrasive Regulator... 2 2.1 Regulator Installation... 2 Location... 2 Attaching the Regulator to the Machine...

More information

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION

INSTALLATION INSTRUCTIONS. CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION INSTALLATION INSTRUCTIONS CVS 67CFR Pressure Reducing Instrument Supply Regulator INTRODUCTION The CVS Controls 67CFR Filter regulator is a pressure reducing supply regulator typically used for pneumatic

More information

DUAL 444C ONBOARD AIR SYSTEM

DUAL 444C ONBOARD AIR SYSTEM DUAL 444C ONBOARD AIR SYSTEM PART NO. 20019 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product.

More information

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP

Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP Binks SG-2 Plus TM Rotary 2 QT. PRESSURE CUP Model No. 80-651 Rotary Agitator INTRODUCTION Binks SG-2 TM Plus Rotary 2 Qt. Pressure Cup is ideal for component spraying and industrial applications where

More information

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator

INSTRUCTION MANUAL. CVS P37 LP Gas Reducing Regulator INSTRUCTION MANUAL CVS P37 LP Gas Reducing Regulator The CVS Controls P37 Regulator is a non-relieving, pressure reducing regulator suitable for use in LP gas applications (Natural Gas and Propane). As

More information

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP!

Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! Halsey Taylor Owners Manual 4410 Freeze Resistant Tubular Fountain STOP! PLEASE READ THE FOLLOWING INFORMATION. ITALLATION ITRUCTIO FOR THE 4410FR FTN. WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE LOCATED

More information

UltRo Dual Flow Reverse Osmosis Water System

UltRo Dual Flow Reverse Osmosis Water System UltRo Dual Flow Reverse Osmosis Water System Congratulations on this great investment to your health. **IMPORTANT NOTE BEFORE YOU BEGIN** We recommend you call your local friendly plumber to ensure proper

More information

XpressFill XF4500C Counter Pressure Can Filler. Operating Instructions

XpressFill XF4500C Counter Pressure Can Filler. Operating Instructions XpressFill XF4500C Counter Pressure Can Filler Operating Instructions ii XPRESSFILL Systems LLC lling machine. ank you for choosing our handcrafted bottle filler as the technology to bottle your passion.

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

Auto EVAP Quick Start Guide

Auto EVAP Quick Start Guide Auto EVAP Quick Start Guide Pg. 13 Note: Never directly hit or drop the leak detector on the CO2 sensor tip, this will cause the sensor to become damaged! Do not get Leak Seeker Solution directly on the

More information

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS

ANDERSON GREENWOOD SERIES 9000 POSRV INSTALLATION AND MAINTENANCE INSTRUCTIONS Procedure-assembly-functional test and performance requirements 1 SCOPE 1.1 This document establishes the general procedure for assembly, functional testing and normal performance requirements of low Series

More information

Model VR6 System. Installation, Operation & Maintenance

Model VR6 System. Installation, Operation & Maintenance Model VR6 System Installation, Operation & Maintenance General: All Archer Instruments chlorination systems are carefully designed and tested for years of safe, accurate field service. All Archer Instruments

More information

5 Gallon EVkeg Operation Manual

5 Gallon EVkeg Operation Manual EV 5 Gallon EVkeg Operation Manual www.evcontainer.com 1 Liner Removal Before any attempt is made to remove the liner, the keg should be fully depressurized. It will be impossible to rotate the handle

More information

accidents which arise due to non-observance of these instructions and the safety information herein.

accidents which arise due to non-observance of these instructions and the safety information herein. 3 GALLON PANCAKE COMPRESSOR Model: 50959 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other masonry.

More information

Baffles and Traps Cryotrap

Baffles and Traps Cryotrap Baffles and Traps 362-6 Cryotrap Varian Low-Profile Water-Cooled Baffles combine 100% optical density with high conductance and unusually low overall height. They are especially useful in applications

More information

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL

2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL 2 GALLON TWIN STACK AIR COMPRESSOR W/ HOSE REEL Model: 52024 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,

More information

Engineering Excellence. Installation Guide

Engineering Excellence. Installation Guide Engineering Excellence Installation Guide Two Handle Kitchen Faucet: 2DM200 2DM201 This product meets the following standards: ASME A112.18.1 ANSI A117.1 ANSI / NSF 61, SECTION 9 CUPC / IAPMO LISTED /

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS EDGEMERE CENTERSET LAVATORY FAUCET INSTALLATION INSTRUCTIONS 708.0 Thank you for selecting American Standard... the benchmark of fine quality for over 00 years. To ensure that your installation proceeds

More information

100C Air Compressor Kit

100C Air Compressor Kit 10010 100C Air Compressor (standard mounting bracket, CE Spec) 10014 100C Air Compressor (no leader hose or check valve, CE Spec) 10016 100C Air Compressor (with Omega Bracket, CE Spec) IMPORTANT: It is

More information

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List

Spray Gun 134-A. 1 Liter High- Pressure Gel Coat. Usage Instructions & Parts List 1 Liter High- Pressure Gel Coat Spray Gun 134-A Usage Instructions & Parts List www.fibreglast.com 1.800.821.3283 385 Carr Drive Brookville, OH 45309 Operating Instructions & Suggestions This is a high

More information

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO

420C AIR COMPRESSOR KIT PART NO C AIR COMPRESSOR KIT PART NO 420C AIR COMPRESSOR KIT PART NO. 42042 460C AIR COMPRESSOR KIT PART NO. 46043 420C 460C IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this

More information

SECTION I REGULATORS

SECTION I REGULATORS SECTION I REULATORS Applications Pressure Regulation for Steam Distribution Single Point or Multiple Use Applications Pressure Control for Steam Plants District Heating Systems Single Stage Reduction Stations

More information

RG1200 Service and Repair Manual

RG1200 Service and Repair Manual Dive Rite RG 1200 Regulator Service and Repair Manual Page 1 Text and Photography by Pete Nawrocky Copyright ( ) 1999-2000, Lamartek, Inc., dba Dive Rite RG1200 Service and Repair Manual First Stage.........................................

More information

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual

BioAerosol Nebulizing Generator. Operation and Maintenance User Manual BioAerosol Nebulizing Generator Operation and Maintenance User Manual INTRODUCTION The BANG or BioAerosol Nebulizing Generator is a unique nebulizer for the generation of aqueous aerosols at a low air

More information

CO2 Tank Conversion Kit P.N , P.N , and P.N

CO2 Tank Conversion Kit P.N , P.N , and P.N Foodservice Group Multiplex Beverage Equipment Installation Instructions for CO2 Tank Conversion Kit P.N. 002247, P.N. 0022505, and P.N. 0025099 Introduction The following instructions cover the installation

More information

Carbon Fiber Tank with EZ Fill system Fill pressure 4,500 psi (310 bar) Output: up to 4,500 psi (310 bar)

Carbon Fiber Tank with EZ Fill system Fill pressure 4,500 psi (310 bar) Output: up to 4,500 psi (310 bar) Carbon Fiber Tank with EZ Fill system Fill pressure 4,500 psi (310 bar) Output: up to 4,500 psi (310 bar) Ver 1, 10/18 Contents Safety System...3 Filling The Air Venturi Ez Fill System...4 Micro Bore Hose

More information

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N

OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC East Market Street York, PA Manual P/N OPERATION MANUAL RTI RHS650 RTI TECHNOLOGIES, INC. 4075 East Market Street York, PA 17402 Manual P/N 035-80589-02 Table of Contents Components... 2 Test... 4 Recovery/Recycling... 5 Evacuation... 7 Charging...

More information

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO

400H HARDMOUNT AIR COMPRESSOR KIT PART NO H HARDMOUNT AIR COMPRESSOR KIT PART NO 400H HARDMOUNT AIR COMPRESSOR KIT PART NO. 40042 450H HARDMOUNT AIR COMPRESSOR KIT PART NO. 45042 400H 450H IMPORTANT: It is essential that you and any other operator of this product read and understand

More information

CROSS REFERENCE PARTS LIST T & S

CROSS REFERENCE PARTS LIST T & S 002711-40 KL41-Y006-KT Cold Spindle Assembly 002712-40 KL41-Y007-KT Hot Spindle Assembly 004R K50-Y011 Finger Hook Assembly 005312-40 KL50-Y027 Pedal Valve Bonnet Assembly 006678-45 K30-1000 Dipperwell

More information

Adjustable. Unloader Valve. O&M Manual. Part #

Adjustable. Unloader Valve. O&M Manual. Part # Adjustable Unloader Valve O&M Manual Unloader Valve Part #60-020-361 ADVANCED PRESSURE SYSTEMS 701 S. Persimmon St., Suite 85 - Tomball, TX 77375 Toll Free in North America: (877) 290-4277 Phone: (281)

More information

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO

250C-IG COMPRESSOR KIT 12V PART NO C-IG COMPRESSOR KIT 24V PART NO 250C-IG COMPRESSOR KIT 12V PART NO. 25050 250C-IG COMPRESSOR KIT 24V PART NO. 25058 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual

More information

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual

ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT Abrasive Regulator II and 800# Pot Manual ABRASIVE SYSTEM ABRASIVE REGULATOR II 800# BULK ABRASIVE DELIVERY POT TABLE OF CONTENTS Contact Information and Customer & Technical Service... 1 1 Introduction... 1 2 Abrasive Regulator... 1 Description:...

More information

The X-11 Molding Chamber

The X-11 Molding Chamber The User Guide to The X-11 Molding Chamber Table of Contents Overview of Features & Specifications... 3 Features... 4-5 Safety & Maintenance... 6 Initial Startup Procedure... 7 Using the X-11... 8-9 Using

More information

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell

Contents. Stainless Steel Side Block. 1.1 Separating the Side Block. Stainless Steel Side Block Reassembly of. Assembly from the Helmet Shell Separating the Side Block Assembly from the Helmet Shell Contents SSB-1 SSB-3 SSB-5 SSB-5 SSB-7 1.1 Separating the Side Block Assembly from the Helmet Shell 1.2 Side Block Assembly Replacement 1.3 Defogger

More information

The Double Ender (Ball Lock Spear)

The Double Ender (Ball Lock Spear) Quick Start Guide Wash and preferably sanitise all parts apart from regulator Assemble according to image here (swapping disconnect and tap types depending on your package) Check all connections are tight

More information

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves.

Discontinued. Powers Controls. Technical Instructions Document No P25 RV Rev. 1, May, RV 201 Pressure Reducing Valves. Powers Controls RV 201 Pressure Reducing Valves Description Features Product Numbers Dual Pressure PRV Technical Instructions Document No. 155-049P25 RV 201-1 Single Pressure PRV The RV 201 Pressure Reducing

More information

Precision and Instrument Regulators 1/4" port size

Precision and Instrument Regulators 1/4 port size Section 8 Precision and Instrument Regulators /" port size Contents -8 Precision Air Pressure Regulator /" ports............ale-8-2 R38 Instrument Regulator Aluminum Model /" ports.........ale-8- -8 R38

More information

RK LEL Sample Draw Aspirator Adapter Operator s Manual

RK LEL Sample Draw Aspirator Adapter Operator s Manual 30-0951RK LEL Sample Draw Aspirator Adapter Operator s Manual Part Number: 71-0017RK Revision: A Released: 6/2/10 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment

More information

PORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS

PORTABLE 5 GALLON AIR TANK ASSEMBLY & OPERATING INSTRUCTIONS PORTABLE 5 GALLON AIR TANK MODEL 472 ASSEMBLY & OPERATING INSTRUCTIONS 349 Mission Oaks Blvd., Camarillo, CA 930 Visit our Web site at http://www.harborfreight.com TO PREVENT SERIOUS INJURY, READ AND UNDERSTAND

More information

Liquid Nitrogen for Duct Cleaning

Liquid Nitrogen for Duct Cleaning Liquid Nitrogen for Duct Cleaning Copyright 2017 NADCA, All Rights Reserved No part of this publication may be reproduced or distributed by any means, electronic or mechanical, including photocopy, recording,

More information

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL

MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL MODEL MN-PWV PRESSURIZED WATER VESSEL ASSEMBLY OPERATING MANUAL Prepared by CR Manning Edited by SC Woidtke Rev August 22, 2011 PRESSURIZED WATER VESSEL OPERATING MANUAL 1. Background 1.1 The Pressurized

More information

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use

Operating Manual. R280 Pressure regulator made of brass. 1. Intended Use Pressure regulator made of brass Operating Manual 1. Intended Use Line or outlet pressure regulators- /reducer for Air, gases and liquids which is designed to effect reduction to a downstream pressure

More information

The number of test stands can be adapted to the special requirements.

The number of test stands can be adapted to the special requirements. Model DPC Model DPC 01 Simultaneous testing of several cylinders and cartridges is possible. For repeated pressure testing of CO2 high-pressure and breathing air cylinders. The number of test stands can

More information

200 PSI COMPRESSORS - MODEL NUMBERS

200 PSI COMPRESSORS - MODEL NUMBERS 200 PSI COMPRESSORS - MODEL NUMBERS 380C AIR COMPRESSOR KIT PART NO. 38033 480C AIR COMPRESSOR KIT PART NO. 48043 380C 480C IMPORTANT: It is essential that you and any other operator of this product read

More information

Operating Instructions Model and Hydrostatic Test Pump

Operating Instructions Model and Hydrostatic Test Pump Operating Instructions Model 39300 and 39301 Hydrostatic Test Pump Dimension Weight Pump Style Capacity Pressure Motor Lubrication Control Gauge Inlet Connection Outlet Connection Discharge Hose Hose Ends

More information

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid

R133 HELYON. Brass high pressure regulator, suitable for compressed air, gas and liquid R133 Brass high pressure regulator, suitable for compressed air, gas and liquid HELYON 5 Chemin du Jubin 6957 DARDILLY Tél. +33 () 7 5 16 7 - Fax +33 () 7 5 16 71 FEATURES High pressure regulator for cylinder

More information

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES 1990 Nissan 240SX 1983-90 AIR CONDITIONING & HEAT General Servicing Diagnostic Procedures All Import Makes & Models Diagnosis is an important first step in A/C

More information

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL

COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL COMBINATION AIR RELEASE DEGASSING (CARD) VALVES INSTALLATION AND MAINTENANCE MANUAL SPECIFICATIONS: The CARD series air valves are available in 3 pipe sizes, 1, 2 and 4 NPT or socket. Maximum inlet pressure

More information

Medical Gas Control Panel

Medical Gas Control Panel Medical Gas Control Panel INSTALLATION & MAINTENANCE MANUAL 255105 (Rev. 6) 2018-04 2 255105 (Rev. 6) 2018-04 1.0 User Responsibilities The information contained in this installation and operation maintenance

More information

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS

PULSATION DAMPENER / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS PULSATION / SUPPRESSOR SERIES PDS PROVIDES MULTIPLE SYSTEM SAFEGUARDS FUNCTIONS: 1. Pulsation Dampener smooths pump flow 2. Surge Suppressor absorbs shocks and vibrations 3. Water Hammer Arrestor eliminates

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock: - Do not disassemble. Do not attempt repairs or modifications. Refer to qualified service agencies for all service and repairs.

More information

Variable Temperature Storage Dewar Mount Inserts

Variable Temperature Storage Dewar Mount Inserts Variable Temperature Storage Dewar Mount Inserts All inserts are available for either Liquid Helium or Liquid Nitrogen Dewars! DStat - External cryostat with insert leg DStatMag - Super Conducting Magnet

More information

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank

MODEL NUMBER: PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock or Electrocution: MODEL NUMBER: 20008 200 PSI AIR SOURCE KIT 200 PSI Compressor on 2.0 Gallon 200 PSI Air Tank IMPORTANT: It is

More information

Operating Instructions Models and Hydrostatic Test Pumps

Operating Instructions Models and Hydrostatic Test Pumps Operating Instructions Models 33100 and 33101 Hydrostatic Test Pumps 33100 DIMENSIONS: WEIGHT: PUMP: MOTOR: CONTROL: GAUGE: DISCHARGE HOSE: 16 (40cm) L x 22 (55cm) W x 18 (45cm) H 87 lbs., 39.5 kg Triplex

More information

SILENTAIRE TECHNOLOGY

SILENTAIRE TECHNOLOGY SILENTAIRE TECHNOLOGY General User and Maintenance Instructions Thank you and congratulations on the purchase of your PANTHER, the leader in the industry of portable air compressors. The PANTHER is built

More information

200 PSI HIGH-FLOW AIR SOURCE KIT

200 PSI HIGH-FLOW AIR SOURCE KIT 200 PSI HIGH-FLOW AIR SOURCE KIT 50% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20008 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO

97C COMPRESSOR KIT 12V PART NO C COMPRESSOR KIT 24V PART NO C COMPRESSOR KIT PART NO 97C COMPRESSOR KIT 12V PART NO. 00097 97C COMPRESSOR KIT 24V PART NO. 02497 98C COMPRESSOR KIT PART NO. 00098 97C 98C IMPORTANT: It is essential that you and any other operator of this product read and

More information

Sunrise Fountain Water Wonders Assembly & Mounting Instructions

Sunrise Fountain Water Wonders Assembly & Mounting Instructions Welcome to the Water Wonders family. A few simple steps will ensure that your Sunrise Fountain remains a soothing, enjoyable fountain that brings the sights and sounds of nature to you. Two important considerations

More information

Installation Instructions

Installation Instructions Installation Instructions COLONY SOFT 7.0 Centerset Lavatory Faucet 7.0 with Speed Connect Drain Congratulations on purchasing your American Standard faucet with the Speed Connect drain, a features found

More information

Direct Operated Precision Regulator Modular Style. Standard Specifications

Direct Operated Precision Regulator Modular Style. Standard Specifications 1 Direct Operated Precision Regulator Modular Style Series P3 Courtesy of Steven Engineering, Inc.-23 Ryan Way, South San Francisco, CA 948-637-Main Office: (65) 588-92-Outside Local Area: (8) 258-92-www.stevenengineering.com

More information

SWIRLFLO Refrigerated fountains with FLEXI-GUARD

SWIRLFLO Refrigerated fountains with FLEXI-GUARD TM INSTALLATION, CARE & USE MANUAL SWIRLFLO Refrigerated fountains with FLEXI-GUARD TM INSTALLER! CAUTION: Review these instructions before beginning installation. Be sure that installation conforms to

More information

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE

MODEL NUMBER: M20005 AIR SOURCE KIT. 30% Duty Compressor on. 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE MODEL NUMBER: M20005 AIR SOURCE KIT 30% Duty Compressor on 2.0 Gallon Air Tank SAVE THIS MANUAL FOR FUTURE REFERENCE USER MANUAL IMPORTANT SAFETY INSTRUCTIONS CAUTION - To reduce risk of electrical shock

More information

TWO POST RAM PACKAGE 55 GALLON

TWO POST RAM PACKAGE 55 GALLON OPERATOR S MANUAL TP1265S5XXXXXXXX INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE. INCLUDE MANUALS: AF1265SXXXXXX Extrusion Pump (97999-1528), RM552X-XXX-XX Two Post Lift / Ram (pn 97999-1445), & S-636

More information

200 PSI FAST-FILL AIR SOURCE KIT

200 PSI FAST-FILL AIR SOURCE KIT 200 PSI FAST-FILL AIR SOURCE KIT 55% Duty Compressor on 2.0 Gallon Air Tank PART NO. 20007 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of

More information

MAINTENANCE PROCEDURE FOR X 650

MAINTENANCE PROCEDURE FOR X 650 MAINTENANCE PROCEDURE FOR X 650 X 650 25. juli 2005-1/6 MAINTENANCE PROCEDURE FOR X 650 2 ND STAGE WARNING: This maintenance procedure is only for appointed Scubapro technicians that completed a course

More information

OWNER S TECHNICAL MANUAL

OWNER S TECHNICAL MANUAL EL SERIES OWNER S TECHNICAL MANUAL DP7002 1 Air Operated Diaphragm Pump Description The DP7002 1 air operated diaphragm pump is the ideal device for the pumping, transfer and dispensing of chemical liquids,

More information

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES

INDUSTRIAL VALVES MODELS: C62-A; C62-D. INSTRUCTION MANUAL Installation Operation Parts Service DIAPHRAGM BYPASS PRESSURE REGULATING VALVES INSTRUCTION MANUAL Installation Operation Parts Service IMPORTANT Record your Regulator model number and serial number here for easy reference: Model No. Serial No. Date of Purchase When ordering parts

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Installation, Operation, and Maintenance Manual Welker Probe Instrument Regulator Model The information in this manual has been carefully checked for accuracy and is intended to be used as a guide for

More information

PRESSURISED PAINT CONTAINER

PRESSURISED PAINT CONTAINER PRESSURISED PAINT CONTAINER MODEL NO: CPP2B PART NO: 3082115 OPERATION & MAINTENANCE INSTRUCTIONS GC0913 INTRODUCTION Thank you for purchasing this CLARKE Pressurised Paint Container. Before attempting

More information

Helium-Oxygen Blender

Helium-Oxygen Blender Helium-Oxygen Blender Service Manual Model No. PM5400 Series PM5500 Series (shown) SAVE THESE INSTRUCTIONS 300 Held Drive Tel: (+001) 610-262-6090 Northampton, PA 18067 USA Fax: (+001) 610-262-6080 www.precisionmedical.com

More information