CONSTANT PRESSURE SYRINGE PUMP
|
|
- Corey Miller
- 5 years ago
- Views:
Transcription
1 A NEW TECHNOLOGY BREAKTHROUGH CONSTANT PRESSURE SYRINGE PUMP ENABLES CONTINUOUS PRESSURE-CONTROLLED INFUSION USE IN CONSTANT FLOW OR CONSTANT PRESSURE MODE ENHANCES SAFETY FOR SENSITIVE EXPERIMENTATION COMPATIBLE WITH A WIDE RANGE OF PRESSURE TRANSDUCERS AUTOMATICALLY ADJUSTS FLOW RATE TO MAINTAIN CONSTANT PRESSURE F O R YO U R F LU I D I C ULTIMATE PUMP A P P L I C A T I O N
2 INTRODUCTION PHDULTRA CP Constant Pressure Syringe Pump Technology Breakthrough! Harvard Apparatus is proud to introduce the syringe pump. This pump is the first of its kind to allow operation under constant pressure or constant flow. Historically, the only means available to dispense at constant pressure has involved the use of various amplifiers and other accessories/ software. The, when combined with virtually any commercially available pressure transducer/amplifier combination with 0-10V DC analog output, results in a constant pressure dispensing system. This sytem can deliver fluids with an applied force up to 1,000 lbs. Our user-friendly touch screen interface allows for simple control of either constant pressure or constant flow-based applications Infusion/Withdrawal Programmable Infusion/Withdrawal Programmable Superior Functionality Using Harvard Apparatus syringe pump technology and software-controlled pressure monitoring, the is able to maintain a user-defined system pressure ±2%. A user-adjustable sensitivity setting allows for the customization of the system response time necessary to attain the set pressure. The allows the user to set pressures in the units of their choice including mmhg, kpa, and psi. Constant Pressure Applications Include: Short-term organ perfusion studies that require the maintenance of physiologic conditions. Introduction of chemical reactants in a controlled manner. Ocular injections and perfusions. Small animal whole-body perfusions. Constant pressure microfluidic mixing. Administration of genetic material into organs without viral vectors. And Many More! To order call techsupport@harvardapparatus.com
3 SYRINGE PUMP SOFTWARE PRECISION MONITORING OF PRESSURE & FLOW Harvard Apparatus Constant Pressure Monitoring Software. Pressure & Flow Rate Data Data can be monitored via RS-232 from the to a PC In practice, the 0-10V analog output of a pressure transducer amplifier is connected to the analog input on the rear panel of the pump. The amplifier or signal conditioner can be provided by the customer, or accomplished with various tranducers and amplifiers available from Harvard Apparatus. The pressure range may be scaled to fit the available transducer voltage output for systems that output less than 10 V. While in constant pressure mode, in addition to the set and actual pressure, the pump displays the flow rate. This data may be output for further analysis with a variety of data acquisition packages. Accuracy & Reproducibility Of course, the may be used in flow mode with its worldrenowned accuracy and reproducibility. All pumps are infuse/withdraw models. When used in flow mode, these offer features such as method storage and flow programming functions to allow the user to create simple to complex methods. The is available in a variety of configurations to suit the desired pressure or flow rate ranges. To order call techsupport@harvardapparatus.com
4 ACCESSORIES SUPERIOR SELECTION OF ACCESSORIES Essential Application Tools The can work with any pressure transducer and amplifier that will output a 0-10V or similar signal. Harvard Apparatus carries a wide variety of pressure transducers and amplifiers to suit your particular application. Our most popular physiological pressure transducer is our APT-300, a fluid-filled unit with a pressure range of ±300mmHg and a sensitivity of 5µV/V/mmHg (±1%). This has an easily replaceable transducer head. For low pressure applications, such as maintaining the pressure in an eye, we have the P75 Venous Pressure Transducer. This pressure transducer has a pressure range of ±75mmHg and a sensitivity of 1mV/mmHg. When the customer requires a separate amplifier, the unit of choice is the model 601 Transducer Amplifier Module, or TAM-A. As a PLUGSYS module, this DC Bridge Amplifier requires the use of a PLUGSYS housing with a power supply. Cases holding 2, 5, or 10 modules are available. APT-300 with Minicase Blood Pressure Transducer P75 Samba Sensor Applications requiring the use of solid-state pressure catheters (as small as 1Fr up to 7Fr) are also compatible. Millar Transducers interface directly with the TAM-A amplifier. Harvard Apparatus provides a full line of accessories to complement any fluidics experiment, as well as syringes in a variety of styles and sizes. These include Harvard Apparatus Stainless Steel syringes for high pressure applications as well as Hamilton microliter and Gastight syringes in a variety of sizes. Tubing choice is essential to any fluidics set-up. The length, type and stiffness of your tubing will affect the flow quality and accuracy of any experiment. Harvard Apparatus provides a full line of Tygon tubing, PEEK tubing and even can provide custom lengths of stainless steel tubing. Please contact us for more information. 200 ml 100 ml Harvard Apparatus High Pressure Stainless Steel Syringes Research Grade Blood Pressure Transducer 50 ml 2.5 ml 20 ml 8 ml To order call techsupport@harvardapparatus.com
5 SPECIFICATIONS & ORDERING INFORMATION FAMILY OF SYRINGE PUMPS Model PHD ULTRA CP Remote Remote HPSI Remote PHD ULTRA XF-CP Remote Type single syringe, single syringe, Flow Accuracy ±0.25% ±0.25% ±0.35% ±0.35% ±0.5% ±0.5% Pressure Accuracy < ±2% < ±2% < ±2% < ±2% < ±2% < ±2% Syringe Size, min/max 0.5 µl to 140 ml 0.5 µl to 140 ml 0.5 µl to 140 ml 0.5 µl to 140 ml 20 ml to 200 ml 20 ml to 200 ml # Syringes Flow Rate: Remote HPSI Remote Minimum 1.56 pl/min 1.56 pl/min 3.06 pl/min 3.06 pl/min nl/min nl/min Maximum ml/min ml/min ml/min ml/min ml/min ml/min Connectors: USB (PC-to-Pump) Type B Type B Type B Type B Type B Type B RS-232 (PC-to-Pump) 9-Pin D-Sub 9-Pin D-Sub 9-Pin D-Sub 9-Pin D-Sub 9-Pin D-Sub 9-Pin D-Sub RS-485* (Pump-to-Pump) IEEE-1394, 6 pos IEEE-1394, 6 pos IEEE-1394, 6 pos IEEE-1394, 6 pos IEEE-1394, 6 pos IEEE-1394, 6 pos I/O & TTL 15-Pin D-Sub 15-Pin D-Sub 15-Pin D-Sub 15-Pin D-Sub 15-Pin D-Sub 15-Pin D-Sub Average Linear Force 34 kg (75 lbs) 34 kg (75 lbs) 91 kg (200 lbs) 91 kg (200 lbs) 200 kg (433 lbs) kg (1,000 lbs) Maximum Pressure (with 100 ml Syringe) 50 psi 50 psi 135 psi 135 psi 290 psi 670 psi Dimensions 30.5 x 21.6 x 17.8 cm 30.5 x 21.6 x 10.6 cm 30.5 x 21.6 x 10.6 cm 30.5 x 21.6 x 18.5 cm 30.5 x 21.6 x 10.6 cm 30.5 x 21.6 x 10.6 cm Control Box (12 x 8.5 x 7 in) (12 x 8.5 x 4.3 in) (12 x 8.5 x 4.3 in) (12 x 8.5 x 7.3 in) (12 x 8.5 x 4.3 in) (12 x 8.5 x 4.3 in) Dimensions 30.5 x 14 x 16.5 cm 30.5 x 14 x 17.8 cm 41.9 x 30.5 x 19.1 cm 41.9 x 30.5 x 19.1 cm N/A N/A Remote Box (12 x 5.5 x 6.5 in) (12 x 5.5 x 7 in) (16.5 x 12 x 7.5 in) (16.5 x 12 x 7.5 in) Weight 4.5 kg (10 lb) 4.8 kg (10.5 lb) 5.4 kg (12 lb) 7.7 kg (17 lb) 13.6 kg (30 lb) 20.9 kg (46 lb) CONSTANT PRESSURE S Y R I N G E P U M P Voltage Range VAC; 50/60 Hz VAC; 50/60 Hz VAC; 50/60 Hz VAC; 50/60 Hz VAC; 50/60 Hz VAC; 50/60 Hz Order # * Option for RS-232 (RJ-11, Pump-to-Pump) must be ordered at time the pump is ordered. ** Maximum pressure will vary with syringe size and applied force To order call techsupport@harvardapparatus.com
6 Contact Information CONSTANT PRESSURE S Y R I N G E P U M P UNITED STATES Harvard Apparatus 84 October Hill Road Holliston, MA, 01746, USA phone toll free (USA Only) fax techsupport@harvardapparatus.com Warner Instruments 1125 Dixwell Avenue Hamden, CT, 06514, USA phone toll free (USA Only) fax support@warneronline.com CANADA Harvard Apparatus Canada Attn: Sales Department 6010 Vanden Abeele Saint-Laurent, Quebec, H4S 1R9, Canada phone (Canada only) fax sales@harvardapparatus.ca FRANCE Harvard Apparatus, S.A.R.L. Attn: Sales Department 6 Avenue des Andes Miniparc Bat Les Ulis Cedex, France phone fax info@harvardapparatus.fr GERMANY Hugo Sachs Elektronik / Harvard Apparatus, GmbH Gruenstrasse 1 D March-Hugstetten, Germany phone +49 (0) fax +49 (0) info@hugo-sachs.de SPAIN Panlab, S.L. / Harvard Apparatus Spain C/Energia, Cornellà, Barcelona, Spain phone (International Sales) phone (Sales in Spain) fax info@panlab.com SWEDEN CMA Microdialysis, AB Box 2 SE Solna phone fax cma@microdialysis.se UNITED KINGDOM Harvard Apparatus, Ltd. Attn: Sales Department Fircroft Way, Edenbridge Kent TN8 6HE, United Kingdom phone fax sales@harvardapparatus.co.uk
Research Grade Blood Pressure Transducer
Research Grade Blood Pressure Transducer USER S MANUAL Research Grade Blood Pressure Transducer, 110 VAC/60 Hz Research Grade Blood Pressure Transducer, 220 VAC/50 Hz MA1 72-4496 MA1 72-4497 Publication
More informationLarge Animal Volume Controlled Ventilator
Large Animal Volume Controlled Ventilator User s Manual Large Animal Volume Controlled Ventilator, 115 VAC/60 Hz Large Animal Volume Controlled Ventilator, 230 VAC/50 Hz MA1 55-0715 MA1 55-0723 Publication
More informationUser s Manual. VentElite Publication REV-1.1
User s Manual VentElite 55-7040 Publication 5420-009 REV-1.1 Table of Contents SUBJECT PAGE # Warranty & Repair Information 3 Manual Description 3 Warranty 3 General Safety Information 4-5 Technical Specifications
More informationFeatures. Main Voltage: Vdc. Input Control Signal: 0-5 Vdc or 4-20 madc (Sourcing) Monitor Output Voltage: 0-5 Vdc or 4-20 madc (Sourcing)
1 X-Flow Mass Flow Controller Flow Range from 0.8 ml/min to 20 l/min Target Markets Laboratory and Process Instrumentation Pharma / Bio-Pharma Equipment Air Quality Monitoring Systems Furnace and Coatings
More informationMinipuls evolution fitted with three 4-channel Medium Flow pump heads. one 4-channel Medium Flow pump head and one 2-channel High Flow pump head
The Minipuls evolution offers enhanced performances for applications such as : > Perfusion chamber > Bioreactor feeding > Purification column > Animal perfusion > LPLC > Media filling > Transfer of viscous,
More informationRM-80 respiration monitor
RM-80 respiration monitor User Manual September 18, 2015 0025-003M 950 North Hague Avenue Columbus, Ohio 43204-2121 USA Sales: sales@colinst.com Service: service@colinst.com Phone: (614) 276-0861 Fax:
More informationDesign Features. General Description
Model thermal Mass Flow Controllers are designed to indicate and control set flow rates of gases. The combines the characteristics and accuracy of conventional mass flow devices into a unique compact design
More informationPPC4E Pressure Controller/Calibrator Superior rangeability and reliability
PPC4E Pressure Controller/Calibrator Superior rangeability and reliability Technical Data ± 0.02 % of AutoRanged spans from ± 1 kpa (0.15 psi) to 14 MPa (2,000 psi) The Fluke Calibration PPC4E brings high
More informationSpecifications...Easy CLIA Classification: Sample Type: Blood gas analyzer operation has never been simpler Sample Size: Measured Parameters PCO2
medicacorp.com easy inside and out With EasyBloodGas, Medica has redefined blood gas analyzer design The sophistication of traditional blood gas analyzers has been packaged in a new compact format with
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005% of reading plus 0.005% of full scale
More informationThe HumiSys. RH Generator. Operation. Applications. Designed, built, and supported by InstruQuest Inc.
The HumiSys RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The new HumiSys with single or dual RH probes capabilities is
More informationGFM. Typical Aluminum GFM Mass Flow Meter NIST MASS FLOW METERS. Principles of Operation. Design Features
Design Features Rigid metallic construction. Maximum pressure of 1000 psig (70 bars). Leak integrity 1 x 10-7 of helium. NIST traceable certification. Built-in tiltable LCD readout. 0-5 Vdc and 4-20 ma
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The HDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationBUBBLER CONTROL SYSTEM
BUBBLER CONTROL SYSTEM Description: The LDBCS is a fully automatic bubbler system, which does liquid level measurements in water and wastewater applications. It is a dual air compressor system with, air
More informationHumiSys HF High Flow RH Generator
HumiSys HF High Flow RH Generator Designed, built, and supported by InstruQuest Inc. Versatile Relative Humidity Generation and Multi-Sensor System The HumiSys HF is a high flow version of the previously
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Healthcare and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
/ Process Calibration Equipment Automated Calibrators Selection Guide Model Features Range Module 1 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP -2.5 to 2.5 mbar (-1 to 1 inh 2 O) -0.95
More informationBETTER SAMPLE CARE. Spark Holland introduces. SPH1299 UHPLC Gradient Pump
BETTER SAMPLE CARE Spark Holland introduces SPH1299 UHPLC Gradient Pump SPH1299 Spark Holland introduces SPH1299 UHPLC Gradient Pump Robust, Precise and Easy to use Innovative pumping technology created
More information973-SF 6 Analyzer. Precise and Stable SF 6 Gas Analyzer REFLECTING YOUR STANDARDS
Precise and Stable SF 6 Gas Analyzer Simultaneous measurement of humidity, SF 6 purity and SO 2 concentration Integrated gas recovery system with automatic pump back Fully automated SF 6 gas testing Fundamental
More informationThe HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator
The HumiPyc - Model 1 - Gas Pycnometer; Density, Moisture, Permeation Analyzer; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Temperature controlled, multi-technique volumetric
More informationVersatility. Accuracy. Compact. Versa. Automated Headspace Vial Sampler
Versatility Accuracy Compact Versa Automated Headspace Vial Sampler Small Size. Big Value. Automated Static Headspace System Static headspace is one of the most popular techniques due to its versatility
More informationAccurate, easy to use and reliable: Easy to use control panel. Clear, backlit LCD display:
Elcometer 2300 Rotational Viscometers The Elcometer 2300 range of rotational viscometers measures the viscosity of liquids in accordance with several standards. Using a rotational viscometer, the properties
More informationAdditel 761 Automated Pressure Calibrators Selection Guide
Automated Calibrators Selection Guide Model Features Range 761-LLP 761-D 761-L 761-LA 761-M 761-MA 761-H 761-HA 761-BP 0.05 to 8 bar.a -0.90 to 25 bar (1.2 to 115 psi.a) (-13 to 375 psi) 0.1 to 26 bar.a
More informationAdditel 761 Automated Pressure Calibrators
Additel 761 Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure modules Built-in
More informationPrecision pressure sensor Basic version Model CPT6020
Calibration Precision pressure sensor Basic version Model CPT6020 WIKA data sheet CT 25.13 Applications Calibration technology High-accuracy pressure monitoring Pressure sensing in critical applications
More informationSeries Ruska Digital Pressure Indicator. GE Sensing & Inspection Technologies. Features
GE Sensing & Inspection Technologies Series 7050 Ruska Digital Pressure Indicator Features Pressure ranges from 0 to 10 inh2o and 0 to 1500 psi (0 to 25 mbar and 0 to 100 bar) Choose from three models:
More informationCRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety
CRRT with Prismaflex LEADS TO More Flexibility, Ease of Use and Safety Leading the way Science is changing and so are your requirements For many years, Gambro has focused its efforts on development of
More informationPneumatic high-pressure controller Model CPC7000
Calibration technology Pneumatic high-pressure controller Model CPC7000 WIKA data sheet CT 27.63 Applications Automotive and avionics industry Industry (laboratory, workshop and production) Transmitter
More informationEPP4 Pressure Regulator Basic G 1/4"
EPP4 Pressure Regulator Basic G 1/4" Flow Curve 1/4" Dimensions Outlet pressure - bar 9 8 7 6 5 4 3 2 1 0 0 20 40 60 70 80 100 120 Flow rate - Nm 3 /h The male connector adopted on the EPP4 is a standard
More informationTSE Blood Pressure Monitor Invasive series
TSE Blood Pressure Monitor Invasive 209100series For Invasive Measurements in Laboratory Animals 2 Specifications subject to change without notice USA / Canada / Mexico Phone 1-989-698-3067 Fax 1-989-698-3068
More informationAbdominal Organ PERFUSION SYSTEMS. Liver Kidney Mesenteric Bed Intraluminal Vessel Perfusion
Abdominal Organ PERFUSION SYSTEMS Liver Kidney Mesenteric Bed Intraluminal Vessel Perfusion www.hugo-sachs.de www.harvardapparatus.com Molecular Sample Prep Pumps Behavioral Research Surgical Solutions
More informationAutomatic Isokinetic Sampler. ST5 Evo
Automatic Isokinetic Sampler ST5 Evo Automatic Isokinetic Sampler ST5 Evo Moreover, in case of pump failure, the CU can work with a spare Dado PU unit or with any pump capable to supply the needed flowrate,
More informationHigh-speed pressure sensor Model CPT6140
Calibration technology High-speed pressure sensor Model CPT6140 WIKA data sheet CT 25.11 Applications Testing technology Calibration technology Laboratories and maintenance shops Leak and burst applications
More informationMouse and Rat Tail Cuff Blood Pressure Systems from 1-24 Animals. Mouse rat tail cuff blood pressure system components
Mouse and Rat Tail Cuff Blood Pressure Systems from 1-24 Animals Mouse rat tail cuff blood pressure system components Tail Cuff Method Sensors Rodent Restrainers Software Chart Recorder Amplifier with
More informationHot extractive multi-channel gas analyser for continuous process and emissions monitoring.
Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions
More informationPrecision digital pressure gauge Model CPG1000
Calibration technology Precision digital pressure gauge Model CPG1000 WIKA data sheet CT 10.01 Applications Oil and gas industry Maintenance and service facilities Calibration service companies and service
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationAnalogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM
Analogue and Digital Mass Flow Meters and Controllers for Gases MASS-STREAM M+W Instruments Your partner Key Facts M+W Instruments was founded in 1988 and has always specialised in thermal mass flow meters
More informationLUMAZOTE T ECHNICAL BRO CHU RE
by Chemiluminescence Standards AST D4629 / ASTM D6069 / ASTM D 5176 / ASTM D 5762 / NF EN 12260 / NF M 07-058 Licence TOTAL LUMAZOTE T ECHNICAL BRO CHU RE ERALY & Associés Phone: +33 (0) 1 77 04 80 97
More informationThe HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator
The HumiPyc ( Model 2) - Gas Pycnometer; Density, Moisture, Permeation Analyzer; Filter Integrity Tester; RH sensor Calibrator Designed, built, and supported by InstruQuest Inc. Universal pycnometer, no
More informationHot extractive multi-channel gas analyser for continuous process and emissions monitoring.
Product Data Sheet CODEL Continuous Emission Monitoring GCEM4100 Extractive Gas Analyser CO, CO2, NO, NO2, SO2, HCL, CH4 & H2O Hot extractive multi-channel gas analyser for continuous process and emissions
More informationSENSAPHONE APPLICATION NOTE. Functions: C Programming, Pump Control, Data Logging
SENSAPHONE APPLICATION NOTE Application: Pump Station Volumetric Flow Calculation Functions: C Programming, Pump Control, Data Logging Sensaphone Model: SCADA 3000 Who needs to perform Volumetric Flow
More informationAC : MEASUREMENT OF HYDROGEN IN HELIUM FLOW
AC 2010-2145: MEASUREMENT OF HYDROGEN IN HELIUM FLOW Randy Buchanan, University of Southern Mississippi Christopher Winstead, University of Southern Mississippi Anton Netchaev, University of Southern Mississippi
More informationADT 761 Automated Pressure Calibrator
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com With a built-in high performance electronic pump and precision pressure controller,
More informationMass Flow Meter (MFM) for gases
Mass Flow Meter (MFM) for gases Type can be combined with Inline MFM for nominal flow rates from 25 l N /min to 1,500 l N /min; 1/4 to 3/4 High accuracy Fast settling time Fieldbus option Special version
More informationAdditel 780 Series Pressure Controller
Additel 780 Series Pressure Controller Pressure / Process Calibration Equipment Pressure ranges from vacuum to 3,000 psi (200 bar) Removable interchangeable intelligent sensors Precision accuracy of 0.005%
More informationAdditel 761 Automated Pressure Calibrators
Automated Calibrators UPDATED Fully automated pressure calibrator with built-in pressure generator / controller to as high as 600 psi (40 bar) or as low as 0.01 Pa (0.00004 inh 2 O) accuracy Dual pressure
More informationIndustrial pressure controller Model CPC4000
Calibration technology Industrial pressure controller Model CPC4000 WIKA data sheet CT 27.40 Applications Oil and gas industry Industry (laboratory, workshop and production) Transmitter and pressure gauge
More informationHUMOR 20. High-precision Humidity Calibrator HUMOR 20. Operation
High-precision Humidity Calibrator The role of humidity calibrations that are accurate, reproducible, and documentable is becoming more and more important. ISO quality guidelines and regulations according
More informationBlood Parameter Monitoring System 550
Technical Compendium CDI Blood Parameter Monitoring System 550 An overview of the CDI System 550 and its industry leading technology. CDI System 550 Measures or Calculates 12 Critical Blood Parameters
More informationDCS Series 1 kw, 1.2 kw, & 3 kw
Established 1981 Advanced Test Equipment Rentals www.atecp.com 800-404-ATEC (2832) DCS Series 1 kw, 1.2 kw, & 3 kw DCS Applications The DCS Family is ideally suited f a wide range of applications requiring
More informationwww.ricelake.com/condec 888-295-8475 UPC5000 PRESSURE CALIBRATION STANDARD Designed for calibrating transmitters, transducers, gauges and other pressure sensitive devices onsite, the portable UPC5000 is
More informationMCQ Gas Blender 100 Series 3 Channels Gas Mixer
Channels Gas Mixer Revision 1.8 October 2016 High Performance Digital Gas flow Gas Dilutor Blender & Gas for Mixing flow Mixing Gases System and Calibration Routines Technical Data Sheet Lab in a box From
More informationHyDefinition HD4070. Plasma Arc Cutting / Marking System. Product Configuration Manual Revision
HyDefinition HD4070 Plasma Arc Cutting / Marking System Product Configuration Manual 803770 Revision 1 4070.97 HD4070 Product Configuration Manual (P/N 803770) Revision 1 December, 2002 Hypertherm, Inc.
More informationX-Flow Mass Flow Controller 授权代理 : 北京品超思瑞科技学院公司
X-Flow Mass Flow Controller 2 Highlights Parker Hannifin Precision Fluidics Division is excited to introduce X-Flow, a new easy to use general purpose mass flow controller for your instrument, lab, or
More informationModel GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272)
Manual Addendum Model GFC 7000T CO 2 Analyzer (Addendum to GFC 7000TA Manual, PN 07272) P/N M07273 DATE 06/11/13 TELEDYNE ELECTRONIC TECHNOLOGIES Analytical Instruments 16830 Chestnut Street City of Industry,
More informationA high flying simplicity DUAL SOFT BAG INJECTION SYSTEM
A high flying simplicity DUAL SOFT BAG INJECTION SYSTEM THE INNOVATIVE SOLUTION for contrast media and saline injection in CT medical imaging Designed for MULTI-USE Dual soft bag injector for MONO & BI-LIQUID
More informationModel 601CV. Mass Flow Controller. Product Features:
Model 601CV Mass Flow Controller Porter s Model 601CV Series II Mass Flow Controller (MFCs) is designed for precise control of virtually all conventional process gases. The MFC consists of a thermal mass
More informationSorensen DCS Series. 1 3 kw V A. General Purpose Systems Power Supply
Sensen DCS Series General Purpose Systems Power Supply High power density / low ripple and noise High programming resolution with Ethernet interface Constant voltage and current mode Remote sensing Isolated
More informationFPG8601 Force Balanced Piston Gauge
FPG8601 Force Balanced Piston Gauge Reference Level Calibration System for very low pressure Pressure range: 0 to 15 kpa gauge, absolute and absolute differential Standard resolution: 0.010 Pa, high resolution
More informationcombustion efficiency monitoring General Purpose Applications Flue gas oxygen analyzers Combustion & Environmental Monitoring An Company
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring An Company Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from ml N /min to 0 l N /min Applicable for aggressive gases Fieldbus option Type 870 can be combined with...
More informationOsmometers. Product Selection Guide. Wissenschaftliche Gerätebau Dr. Ing. Herbert Knauer GmbH Hegauer Weg Berlin
Osmometers Product Selection Guide Osmometer Semi-Micro Osmometer K-7400 The Semi-Micro Osmometer enables freezing point depression to be measured. Additionally, the total osmolality of physiological and
More informationBUYER S GUIDE AQUAlogger 530WTD
OCEAN & ENVIRONMENTAL BUYER S GUIDE AQUAlogger 530WTD Wireless Temperature and Depth Logger AQUAlogger 530WTD The AQUAlogger 530WTD has an innovative design that includes the ability to transfer stored
More informationUNDERSTANDING, ACCELERATED
UNDERSTANDING, ACCELERATED MEASURE FLOW, PRESSURE, AND TEMPERATURE ALL IN ONE INSTRUMENT! Designed for Performance TSI thermal mass flowmeters incorporate a proprietary platinum film sensor design for
More informationUser Manual MFCS TM -EZ
User Manual MFCS TM -EZ Version 6A_December 2016 1. INTRODUCTION 5 2. GENERAL INFORMATION 6 2.1 General functioning 6 2.2 Different MFCS TM 6 3. PACKAGE CONTENT 8 4. MFCS TM -EZ DESCRIPTION 9 5. CONNECTIONS
More informationCertified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters
www.kem-kueppers.com info@kem-kueppers.com Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass
More informationC-Flow Coriolis Mass Flow Meters
Coriolis Mass Flow Meters Ready for Take Off The New Compact C-Flow Küppers Elektromechanik GmbH The C-Flow The C-Flow Coriolis Mass Meters consist of two components: KCE Transmitter KCM Transducer 2 KEM
More informationINSTRUCTION MANUAL. FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model Version Perma Pure LLC Tel:
PERMA PURE INSTRUCTION MANUAL FLOW CONTROL DRAWERS MANUAL / PLC CONTROL SERIES Model 3300 Version 4.06 Perma Pure LLC Tel: 732-244-0010 P.O. Box 2105, 8 Executive Drive Tel: 800-337-3762 (toll free US)
More informationBAROMETER PRESSURE STANDARD PRESSURE CONTROLLER
BAROMETER PRESSURE STANDARD PRESSURE CONTROLLER Features ±0.01% FS Measurement & Control Accuracy ±0.001% /ºC Thermal Stability Pressure Ranges from ±1 psid to 1200 psia Applications Barometric Measurement
More informationMiniature Electronic Pressure Controllers. Precision Fluidics
Miniature Electronic Pressure Controllers Precision Fluidics 2 When you partner with the global leader in motion and control technologies, expect to move your business and the world forward. From miniature
More informationAUTOMATIC HOSE TEST UNIT, TYPE SPU
VALVES AND FITTINGS UP TO 14,000 BAR TEST AND CONTROL EQUIPMENT H IGH PRESSURE TECHNOLOGY AUTOMATIC HOSE TEST UNIT, TYPE SPU Pressure range from 1 up to 10,000 bar User-friendly touch panel operation HIGH-PRESSURE
More informationHand-held pressure calibrator with integrated pump Model CPH6600
Calibration technology Hand-held pressure calibrator with integrated pump Model CPH6600 WIKA data sheet CT 16.01 Applications Calibration service companies and service industry Measurement and control
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Bypass MFC with capillary technology for nominal flow rates from 5 ml N /min to 15 l N /min Applicable for aggressive gases Compact design and digital communication
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type 8713 can be combined with... Direct flow measurement by MEMS- Technology for nominal flow rates from 1 ml N /min to 8 l N /min (N 2 ) High accuracy and repeatability
More informationSTARLOG. Capacitive Water Depth Probe
STARLOG Capacitive Water Depth Probe Model 6521 User Manual Supplement 6219 Revision D July 10. 1998 Copyright Notice Copyright Unidata Australia 1998. All rights reserved. No part of this publication
More informationIntelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter
Intelligent SUNTEX DC-5310(RS) Dissolved Oxygen Transmitter Overview C % ppm 4~20mA Analog Output ppb Power Supply 100~240 VAC mg/l Dimensions 96 x 96 x 132mm RS-485 Digital Output (for DC-5310-RS only)
More informationCO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O. Extractive low cost, low maintenance devices for continuous process and emissions monitoring.
Product Data Sheet CODEL Continuous Emission Monitoring GCEM 40 Series Extractive Gas Analyser CO, NO, NO 2, NO x, SO 2, CH 4, HCl, CO 2 & H ² O Extractive low cost, low maintenance devices for continuous
More informationHydraulic hand test pump Models CPP700-H and CPP1000-H
Calibration technology Hydraulic hand test pump Models CPP700-H and CPP1000-H WIKA data sheet CT 91.07 for further approvals see page 2 Applications Simple test pressure generation on site, in the laboratory
More informationThe instrument will process the samples one by one till all the samples have been cleaned up.
Table of Contents SPE-01 Cleanup Station... 1 LC-04SP Valve System... 5 LC-04SP Standalone Valve... 10 LC-05 Auto Injector... 12 LC-06 Dosing Pump... 16 LC-08 Column Selector... 17 SPE-01 Cleanup Station
More informationDigital pressure gauges
Digital pressure gauges Digital pressure gauges are particularly suitable for both stationary and mobile measurement and display of pressure. They can be used as reference pressure gauges to simplify the
More informationHPFM GEN3 - High Pressure Flow Meter
HPFM GEN3 - High Pressure Flow Meter Principle of Measurement Specifications System overview Features & Benefits Operation Procedure Calibration Applications HPFM - Hydraulic Conductance The HPFM is an
More informationAMS 6915 Board mount pressure sensor with digital output (I²C)
Board mount pressure sensor with digital output (I²C) FEATURES Calibrated and temperature compensated pressure sensor with digital output (I²C) Differential, relative (gage), bidirectional differential,
More informationMass Flow Controller (MFC) for Gases
Mass Flow Controller (MFC) for Gases Type can be combined with... Direct flow measurement with CMOSens - Technology for nominal flow rates from 20 ml N /min to 80 l N /min (N 2 ) High accuracy and reproducibility
More informationNT High-temperature flowmeter model Simultaneous flow and pressure outputs for high-temperature applications
NT High-temperature flowmeter model 4401 Simultaneous flow and pressure outputs for high-temperature applications high-temperature flow measurement Overview Now more than ever there is a need to measure
More informationUsed with Dissolution Tester for Fraction and Flow Measurements
TOYAMA Auto Sampler W, Model PAS-615 Used with Dissolution Tester for Fraction and Flow Measurements This is a full automatic sampler to be used with 6-shaft or 8-shaft dissolution tester, with the following
More informationPressure transmitter PASCAL Ci4
Pressure transmitter PASCAL Ci4 for general application,type Series CI4100 Features Pressure transmitter for the measuring of relative and absolute pressures of gases, vapors and liquids High-resolution
More informationKERN EG/EW Version /02
E KERN EG/EW Version 1.5 07/02 Operating Instructions Electronic Precision Balances Contents 1 TECHNICAL DATA... 20 2 UNPACKING AND STANDARD ACCESSORIES... 23 3 SETTING UP THE BALANCE... 23 4 EXTERNAL
More informationP9000 DESCRIPTION. For parts requiring RoHS compliance, please contact factory. P February /6
P9000 High accuracy through digital compensation High thermal stability Rugged stainless steel construction Ideal for test stands High burst pressure limit DESCRIPTION The P9000 Series is a range of advanced,
More informationPRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa)
Instruction Sheet for the PASCO Model CI-6532A PRESSURE SENSOR - ABSOLUTE (0 TO 700 kpa) 012-06859B 10/98 $1.00 polyurethane tubing syringe cable with DIN s to computer interface quick release s (4) pressure
More informationWL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination
WL16 WATER LEVEL LOGGERS Submersible pressure transducer and USB datalogger combination Warning: Non-vented water level loggers may have readings with errors of up to 250mm due to barometric pressure changes.
More informationElectronic gas volume corrector model DGVC-04
Electronic gas volume corrector model DGVC-04 1. Introduction The following user s manual gives information about the installation, configuration, usage and storage of the electronic gas volume corrector
More informationMass Flow Controllers
Mass Flow Meters & Controllers HFM-D-3A & 305A Mass Flow Meters HFC-D-3A & 307A Mass Flow Controllers FEATURES Range 0-25 slm to 0-2500 slm (N 2 Equivalent) Excellent Accuracy ±(0.5% of Reading + 0.2%
More informationMEGAS 2.0. Gas analysis with direct C-Level Calculation and Bus-Connection. Data sheet
Data sheet MEGAS 2.0 Gas analysis with direct C-Level Calculation and Bus-Connection Mesa Industrie-Elektronik GmbH Neckarstraße 19, D-45768 Marl info@mesa-gmbh.de +49 (0) 2365-97 45 1-0 +49 (0) 2365-97
More informationcombustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring
combustion efficiency monitoring Flue gas oxygen analyzers General Purpose Applications Combustion & Environmental Monitoring Flue Gas Oxygen Genesis is a range of flue gas analyzers for measuring Oxygen
More informationOil Diagnostic Systems. Online and bottle measurement Mobile and stationary operation Lab quality accuracy e
Oil Diagnostic Systems Online and bottle measurement Mobile and stationary operation Lab quality accuracy 100.90-1e The new generation of oil diagnostics Mobile and stationary operation: Compressed air
More informationThis multi-functional device allows the determination of up to six quality parameters with only one measurement:
Devices for determination of the gas quality For verification of several parameters in one operation 3-038-R... Multi-Analyser without return system 3-038R-R... Multi-Analyser with return system This multi-functional
More informationSonoMeter 30 Energy Meters
Data Sheet SonoMeter 30 Energy Meters Description The Danfoss SonoMeter 30 is a range of ultrasonic, compact energy meters intended for measuring energy consumption in heating and cooling applications
More informationOperating Instructions
Operating Instructions for the ISOTEC Pressure Transducer Version 1.2, Steiert 2/00 Printed March 6, 2002 Contents Page 1 Preliminary notes... 1 2 Application... 1 3 Introduction... 1 4 Unpacking, components,
More information